1 Cooling Capacity 3.5kW kW Heating Capacity 4.4kW kW eco series Water-Cooled Air Conditioning Giving you complete control
2 More than just another air conditioning company. We re dedicated to pioneering innovative new technologies and creating market-leading, easy-to-use solutions that offer you complete control. The sky s the limit with Temperzone water-cooled When buildings head skyward, only Temperzone s water-cooled air conditioning system has what it takes to meet your climate control challenges. A key fixture of many CBD high-rise developments throughout ceania and Asia, our innovative water-cooled units are more reliable, economical, flexible, and environmentally friendly than any air-cooled alternative. And while other systems struggle to deliver as the floors stack up, our technology has been engineered to deliver optimum performance in multi story buildings particularly those exceeding 15-storeys. Why water-cooled rules the roost up high Temperzone s water-cooled technology combines the benefits of a water-cooled condenser with an air-cooled evaporator, delivering a level of performance that air-cooled units can t. Available in capacities from 3.5kW to 101.6kW, they re also designed to run on individual power sources, eliminating the need to install expensive central plants. And because they re designed to fit into virtually any internal space or cavity, they re ideal for high-rise buildings that prohibit the use of balcony units. Enabling pump power savings of up to 36% and carbon emission reductions of up to 20%, a Temperzone water-cooled system can also play a central role in developing a sustainable energy strategy or energy upgrade for any building. age 1
3 How our water-cooled systems can change with the times Rather than having to plan your entire air conditioning layout in advance, Temperzone s water-cooled modular technology offers you the unique ability to expand or adapt your system as a building s commercial demands evolve. Multiple units can be used to cater for vastly different uses within the same building. For example, you can choose to cool or heat a large open-plan office area while also employing a range of separate water-cooled units to service 20 small meeting rooms. And because each unit connects to an individual meter and power source, users are only billed for their own usage. It s just another way Temperzone s water-cooled range gives tenants complete control of their air conditioning needs. Why Temperzone? As innovative market leaders in air conditioning technology development, Temperzone is ideally positioned to play a partnering role in your commercial projects and to ensure you select the right solutions for your needs. Because our systems are all designed, manufactured and supported using home-grown expertise, you can always rely on the convenience of ready availability and easily accessible technical support. EC HW - Energy efficiency comparison AEER % % 1st Gen. HW * MES New Gen HW ** EC HW ** * HW 301 ** HW 118 age 2
4 Why more builders and developers are turning to Temperzone water-cooled technology Unprecedented flexibility, outstanding economy and solid green credentials are only the start. ther benefits include: Easy installation procedure simply add power and tap into a water supply. Simple design that ensures servicing can take place without shutting down the entire building. High reliability levels and low maintenance requirements. Low noise levels. BMS compatibility, enabling you to remotely monitor and quickly identify faults in individual units.* The ability to cope with a wide range of water temperatures, enabling our units to deliver outstanding performance.* Ease when retrofitting. BMS located in the basement lant Room BMS communication cable (2 wire shielded). Maximum cable length is 1000m. BMS * Refer to Temperzone age 5
5 Best In-Class Comfort and Saving Temperzone s state-of-the-art ThermoShell technology and intuitive controls enable precise room temperature settings, energy savings, and the flexibility of individual room comfort within a large complex. ThermoShell Efficiency ffering up to 6% reduction in nominal water flow rate and up to 34% reduction in water pressure drop, Temperzone s state-of-the-art ThermoShell sets new standards in water-cooled technology. Enabling a reduction in hydronic equipment size, it reduces capital and operating costs while increasing building sustainability. Technological advancements HW Comparison 0.36 l/s 0.34 l/s 6% reduction Nominal water flow rate revious ThermoShell R 62 HW # HW ## ka 41 ka 34% reduction Water pressure drop revious HW + ThermoShell R HW ++ # HW 58 ## HW 59 + HW HW 98 age 7
6 Technological advancements Cost Savings with ThermoShell Temperzone s state-of-the-art ThermoShell sets new standards in water-cooled technology. ThermoShell technology is Temperzone s new high performance, compact heat-exchanger for refrigerant and water systems. 42 ka 66% reduction Life Long Efficiency Unlike coaxial and plate-type heat exchangers, ThermoShell prevents degradation in heat transfer efficiency due to water fouling, facilitating reliable operation throughout the unit service life. ThermoShell Heat Exchanger ThermoShell enables considerably lower water flow rates and water pressure drops to be accommodated by the system, with minimal effect on duty and efficiency. This leads to a reduction in hydronic equipment size, reducing capital and operating costs. The effect of a decreased water flow rate through a non EC Fan model HW 59 with ThermoShell was measured under laboratory conditions to examine the overall effect on duty and EER*. 5 C differential 14 ka 9 C differential Water pressure drop Refrigerant Water ath Non fouling surface It was shown that increasing the temperature differential across the condenser to 9 C by significantly decreasing the water flow rate had only a minimal effect on the duty and EER of the unit (from 3.65 to 3.43). Individual units will run much more efficiently when only a proportion of the units are operating at any one time. Therefore real world efficiencies will be greater then design efficiencies l/s 0.20 l/s 45% reduction Water flow rate Coaxial Heat Exchanger iping has a very undulated surface making it prone to extreme water fouling. water out refrigerant in late Heat Exchanger Many plates at extremely close intervals create a very receptive fouling surface. Contact the Temperzone team to help you analyse the benefit for your individual project. 5 C differential 9 C differential Refrigerant in Refrigerant in Water out late Water in late # HW 59 was tested under typical conditions of IAT 27/19 C, EWT 30 C, age 8 age 9
7 Technological advancements EC Variable Speed Fans Simultaneous Cooling and Heating Temperzone s EC fan motors allow precision comfort control and leading high energy efficiency. Each unit allows a simultaneous same-floor heating and cooling capacity via a single water piping system. EC motors have the added benefit of a longer motor life due to lower operating temperatures and a longer bearing life due to soft start feature. EC Motor (%) Input ower (%) High efficiency EC fan motors are more efficient than induction motors. They operate quietly with a slow ramp up and no sudden noise changes. Gain precision air flow control with custom select fan speeds or utilise continuous fan speed through BMS control. AC Motor (%) energy savings C 25 C C C Air Flow (%) Cooling Tower 20 C Cooling Tower New Gen HW 20 C New Gen HW Cooling Tower Supply water 30 C Supply water 30 C Return water 35 C Return water 35 CHW New Gen Control* Temperzone s individual UC Intuitive control system makes it easy to maintain a space at the prescribed temperature. revious HW Supply water 30 C +17 to +50 C revious HW +17 to +50 C The lower end of cooling and heating functions have been extended to New Gen HW +5 to +50 C Return water 35 C enable a water temperature operating range to 5 C, creating a wider spectrum New Gen HW +5 to +50 C of potential applications It offers the flexibility to exert complete control on climate and comfort outcomes, or allow the control system to make the decisions for you C) EWT range water flow ( in cooling 35at nominal40 50 HW 96 ** HW 98 EWT range in cooling at *nominal water flow ( C ) * HW 96 ** HW 98 revious HW Controlled via an easy-to-use, wall-mounted SAT-3 or TZT-100 touch pad featuring LCD display panel, possible system upgrades include multiple-room controllers, remote temperature sensors and individual temperature control. New Gen HW to +50 C +5 to +50 C EWT range in cooling at nominal water flow ( C ) * HW 96 ** HW 98 * Refer to Temperzone for application * age 10 Min. 5 C with water regulating valve, Min. 15 C without water regulating valve. age 11
8 Standard Features Versatility Flexible handing configurations Galvanised Steel construction AS compliant Insulation Internal condensate pump* 12mm G2 rated filters supplied** Efficiency Thermo Shell technology** High Efficiency EC Fan Motors* Epoxy coated Evaporator Coils Advanced Rifle bore Copper Tubes 13mm foil face closed cell polyurethane insulation High efficiency compressors Control Intuitive UC Control** recise Temperature Control BMS Connectivity with Modbus** BMS Connectivity with BACnet* 3rd arty Control Integration with 12VAC or 24VDC control* Dry Contact Fault utput* 0-10V EC Fan Motor speed* Electronic Regulating Valve Signal ump call and pump flow verifications Installation Ease of wiring Low rofile models Vertical handling on CW Adjustable Indoor Airflow control Rigid structural construction Simplistic maintenance with Access anels Drain tray compliant to AS3666 Removal drain pan* Rectangular spigot EC Fans* Increase energy savings at part load conditions with variable 0-10V dc control signal Increase fan reliability and efficiency by soft starting Superior noise attenuation with forward curved fans AC Fans* Increase comfort conditions with 3 speed control Superior noise attenuation with forward curved fans ThermoShell Heat exchanger** Superior heat transfer with counter flow finned rifle bore copper tubes to suit harsh conditions Long life non-fouling technology Coils Superior epoxy coated fins and advanced rifle bore copper tubes Sheet metal Durable galvanised steel cabinet Durable polyester powder drain tray Leak free access door construction Easy service and maintenance access using panels Insulation Highly durable closed cell foam insulation to ensure no particles are introduced into the air stream Meets fire test standards AS (1989) and BS 476 parts 6 and 7 Controls BMS integration with Modbus and BACnet* communication protocol** Easy integration with 3rd party controls with 12VAC or 24VDC control** * Contact Temperzone ** HW age 12 age 13
9 Water-Cooled is the Better Choice Temperzone HW vs Chiller Feature Comparison Temperzone HW vs VRF Feature Simple Individual Metering / Billing Low Building perating Cost Flexible / Expandable Design Low Installation Cost Comparison HW: ackaged indoor unit operating costs register via separate power meters in individual residences, tenants pay for electricity in accordance with their usage. VRF: As power consumption is incurred predominately at the outdoor units servicing the entire building, users have no control over individual electricity costs. HW: Maintenance costs are lower, with a simple and localised service of packaged units and controls undertaken at the tenant s expense. There is no need for complex centralised controls. The system is easy to operate and does not require a dedicated specialist. VRF: Feature a complex system of components, controls, electrical wiring and piping that renders maintenance much more technical and costly. HW: If a water loop is provided during the building process, each resident can decide whether or not to have air conditioning. For renovation and expansion projects, self-contained units can utilise existing water lines for the condenser loop, and can easily be added. VRF: Indoor units cannot be added to a loop once installed, as the system will have been designed to a specific capacity. HW: Featuring a simple two-pipe system, packaged units are easy to install and require very little specialist technical expertise. All components within the packaged unit are factory-assembled and tested to reduce commissioning costs. VRF: Entails a lengthy, complex and expensive installation with high specialist technical expertise required. Complicated on-site tasks of pipe laying, evacuation, gas charging and leak testing must be undertaken. Complex controls mean high commissioning costs. Simple Individual Metering / Billing High artial Load Efficiency Low Building perating Cost Flexible / Expandable Design Available Floor Space ptimised HW: ackaged indoor unit operating costs register via separate power meters in individual residences, tenants pay for electricity in accordance with their usage. Chiller: As power consumption is incurred predominately at the chiller servicing the entire building, users have no control over individual electricity costs. HW: The system can cope effectively and economically at partial loads as low as 3.5kW (such as might occur with a single office on a weekend). It only requires a pump and cooling tower to operate. The water loop moves energy around a building very efficiently, with unit capacity or efficiency unaffected by the length of the loop. Chiller: Chillers must run at a minimum operation level of approx % of their total load (for a 350kW Chiller, 25% is about 88kW), leading to wastage at partial operation. HW: Maintenance costs are lower, with a simple and localised service of packaged units and controls undertaken at the tenant s expense. There is no need for complex centralised controls. The system is easy to operate and does not require a dedicated specialist. Chiller: Feature a complex system of components, controls, electrical wiring and piping that renders maintenance much more technical and costly. HW: If a water loop is provided during the building process, each resident / tenant can decide whether to install air conditioning operating out of the building system. During renovations, fit outs etc. water cooled units can be easily added to the water loop. Chiller: Adding additional indoor units after the system is commissioned and operating can be costly. HW: The system requires space for a cooling tower and pumps to be positioned on the roof, allowing maximum use of floor and parking space. Chiller: A large water cooled chiller is generally located within a plant space, taking up valuable floor or parking space. Very Long Life System HW: Temperzone water-cooled systems are durable and have a long life expectancy. The system is not dependent on unique branded electronics and components. VRF: Require the use of specific technologies and systems. Due to compatibility problems with other manufacturer systems, parts must be replaced with specific product brand electronics and components. Lack of parts availability will necessitate the installation of a whole new system. Low Installation Cost HW: Featuring a simple two-pipe system, packaged units are easy to install and require very little specialist technical expertise. With water temperatures of between 26 C and 36 C, insulated water piping is not required. There are also no condensation problems. Chiller: Chiller systems require a four-pipe system - two for condenser water and two for chilled water. Chilled water pipes and pumps must be heavily insulated. They usually encounter condensation problems due to low water temperatures (5 C to 14 C). age 14 age 15
10 Standard Range options and features Capital vs. Running Costs The range of options available allow you to customise your desired unit, giving you ultimate control and flexibility. Spending more on an energy efficient unit at the outset will save on running costs and ongoing maintenance well into the future. Series HW HW HW Model EC Fan Motor (Y) version AC Fan Motor version Reverse Cycle Cooling nly^ Cost Additional maintenance costs. Higher running costs each year which may escalate with energy prices growing. Cooling/Electrical Heat 0-10VDC Fan Speed Control + Handing ptions $$ EC+ system. Higher initial cost Less running costs means the machine has paid for itself within a few years. BMS Connection $ Standard system. Lower initial cost Series CW CW CW CW Model Time EC Fan Motor 0-10VDC Fan Speed Control Reverse Cycle Cooling nly Cooling/Electrical Heat* Handing ptions Cabinet Colour ption BMS Connection TIN STANDARD N/A + EC Fan Motor version only ^ Not available in Australia Contact the Temperzone team to help you crunch the numbers on your project. age 16 age 17
11 Eco Range Horizontal Single hase HW-Y Specifications HW 59 Model HW 36Y HW 48Y HW 59Y HW 79Y HW 98Y Capacity (Range) kw Nominal Cooling Capacity 2 (kw) Net Cooling Capacity (kw) Efficiency Cooling (EER/AEER) / / / / / 3.94 Heating Capacity 3 (kw) Efficiency Heating (C/AC) 4.08 / / / / / 4.34 Electric Heat ption (kw) Nominal Supply Air Flow l/sec Sound ressure Level 4 db(a) ower Supply 1 Single hase ( V 50Hz) Single hase ( V 50Hz) Run Amps at Nominal Conditions Heat Exchanger ThermoShell ThermoShell Water Flow l/sec Water ressure Drop ka / psi 27.6 / / 4 41 / 6 70 / / 6 Water Connections Ø mm / BS 13 / ½" 13 / ½" 13 / ½" 19 / ¾" 19 / ¾" Dimensions (mm) Width Height Depth Weight (kg) Weight (excluding water) NTES: 1 Voltage fluctuation limits: Single hase models V.a.c. 2 Nominal Cooling Capacity at AS/NZS conditions: Entering Water Temperature 30 C; Entering Air Temperature 27 C D.B., 19 C W.B. 3 Heating Capacity (HW R version only) at AS/NZS conditions: Entering Water Temperature 21 C; Entering Air Temperature 21 C D.B. 4 SL measured to JIS 8616 (1 m from source) at nominal supply air flow, with 1 m insulated duct. 5 ressure Drops based on nominal water flow. 6 Reverse Cycle Series. 7 EER/AEER based on reverse cycle series Materials and specifications subject to change without notice due to the manufacturer s ongoing research and development programme. roduct of the Year Category age 18 age 19
12 Eco Range Horizontal Three hase HW-Y Specifications HW 118 Model HW 118Y HW 142Y HW 172Y HW 192Y HW 255Y HW 275Y Capacity (Range) kw Nominal Cooling Capacity 2 (kw) Net Cooling Capacity (kw) Efficiency Cooling (EER/AEER) / / / / / / 4.47 Heating Capacity 3 (kw) Efficiency Heating (C/AC) 3.92 / / / / / / 4.36 Electric Heat ption (kw) Nominal Supply Air Flow l/sec Sound ressure Level 4 db(a) ower Supply 1 3 hase 400V 50Hz 3 hase 400V 50Hz Run Amps at Nominal Conditions / 4.1 / / 4.6 / / 6.0 / / 7.0 / / 8.0 / / 9.5 / 9.5 Heat Exchanger ThermoShell ThermoShell Water Flow l/sec Water ressure Drop ka / psi 55 / 8 69 / / / 5 48 / 7 55 / 8 Water Connections Ø mm / BS 19 / ¾" 19 / ¾" 25 / 1" 25 / 1" 25 / 1" 25 / 1" Dimensions (mm) Width Height Depth Weight (kg) Weight (excluding water) NTES: 1 Voltage fluctuation limits 3 hase models V.a.c. 2 Nominal Cooling Capacity at AS/NZS conditions: Entering Water Temperature 30 C; Entering Air Temperature 27 C D.B., 19 C W.B. 3 Heating Capacity (HW R version only) at AS/NZS conditions: Entering Water Temperature 21 C; Entering Air Temperature 21 C D.B. 4 SL measured to JIS 8616 (1 m from source) at nominal supply air flow, with 1 m insulated duct. 5 ressure Drops based on nominal water flow. 6 Reverse Cycle Series. 7 EER/AEER based on reverse cycle series Materials and specifications subject to change without notice due to the manufacturer s ongoing research and development programme. roduct of the Year Category age 20 age 21
13 Horizontal Single hase HW Specifications HW 59 Model HW 36 HW 48 HW 59 HW 79 HW 98 Capacity (Range) kw Nominal Cooling Capacity 2 (kw) Net Cooling Capacity (kw) Efficiency Cooling (EER/AEER) / / / / / 3.76 Heating Capacity 3 (kw) Efficiency Heating (C/AC) 3.82 / / / / / 4.21 Electric Heat ption (kw) Nominal Supply Air Flow l/sec Sound ressure Level 4 db(a) ower Supply 1 Single hase ( V 50Hz) Single hase ( V 50Hz) Run Amps at Nominal Conditions Heat Exchanger ThermoShell ThermoShell Water Flow l/sec Water ressure Drop ka / psi 27.6 / / 4 41 / 6 70 / / 6 Water Connections Ø mm / BS 13 / ½" 13 / ½" 13 / ½" 19 / ¾" 19 / ¾" Dimensions (mm) Width Height Depth Weight (kg) Weight (excluding water) NTES: 1 Voltage fluctuation limits: Single hase models V.a.c. 2 Nominal Cooling Capacity at AS/NZS conditions: Entering Water Temperature 30 C; Entering Air Temperature 27 C D.B., 19 C W.B. 3 Heating Capacity (HW R version only) at AS/NZS conditions: Entering Water Temperature 21 C; Entering Air Temperature 21 C D.B. 4 SL measured to JIS 8616 (1 m from source) at nominal supply air flow, with 1 m insulated duct. 5 ressure Drops based on nominal water flow. 6 Reverse Cycle Series. 7 EER/AEER based on reverse cycle series Materials and specifications subject to change without notice due to the manufacturer s ongoing research and development programme. age 22 age 23
14 Horizontal Three hase HW Specifications HW 118 Model HW 118 HW 142 HW 172 HW 192 HW 255 HW 275 HW 370 HW 445 Capacity (Range) kw Nominal Cooling Capacity 2 (kw) Net Cooling Capacity (kw) Efficiency Cooling (EER/AEER) / / / / / / / / 3.41 Heating Capacity 3 (kw) Efficiency Heating (C/AC) 3.80 / / / / / / / / 3.64 Electric Heat ption (kw) Nominal Supply Air Flow l/sec Sound ressure Level 4 db(a) ower Supply 1 3 hase 400V 50Hz 3 hase 400V 50Hz Run Amps at Nominal Conditions / 3.7 / / 4.6 / / 6.0 / / 7.0 / / 8.0 / / 9.5 / / / / / Heat Exchanger Thermoshell Tube/Tube Water Flow l/sec Water ressure Drop ka / psi 55 / 8 69 / / / 5 48 / 7 55 / / / 5 Water Connections Ø mm / BS 19 / ¾" 19 / ¾" 25 / 1" 25 / 1" 25 / 1" 25 / 1" 32 / 1¼" 32 / 1¼" Dimensions (mm) Width Height Depth Weight (kg) Weight (excluding water) NTES: 1 Voltage fluctuation limits 3 hase models V.a.c. 2 Nominal Cooling Capacity at AS/NZS conditions: Entering Water Temperature 30 C; Entering Air Temperature 27 C D.B., 19 C W.B. 3 Heating Capacity (HW R version only) at AS/NZS conditions: Entering Water Temperature 21 C; Entering Air Temperature 21 C D.B. 4 SL measured to JIS 8616 (1 m from source) at nominal supply air flow, with 1 m insulated duct. 5 ressure Drops based on nominal water flow. 6 Reverse Cycle Series. 7 EER/AEER based on reverse cycle series Materials and specifications subject to change without notice due to the manufacturer s ongoing research and development programme. age 24 age 25
15 Vertical Single hase CW Specifications CW 0132 Model CW 0063 CW 0083 CW 0096 CW 0109 CW 0132 Capacity (Range) kw Nominal Cooling Capacity 2 (kw) Net Cooling Capacity (kw) Efficiency Cooling (EER/AEER) 3.53 / / / / / Heating Capacity 3 (kw) Efficiency Heating (C/AC) 4.31 / / / / / 3.80 Electric Heat ption (kw) Nominal Supply Air Flow l/sec Sound ressure Level 4 db(a) ower Supply 1 Single hase ( V 50Hz) Single hase ( V 50Hz) Run Amps at Nominal Conditions Heat Exchange Tube/Tube Tube/Tube Water Flow l/sec Water ressure Drop ka / psi 20.7 / / / / / 6 Water Connections Ø mm / BS 19 / ¾" 25 / 1" 25 / 1" 25 / 1" 32 / 1¼" Dimensions (mm) Width Height Depth Weight (kg) Weight (excluding water) NTES: 1 Voltage fluctuation limits 3 hase models V.a.c. 2 Nominal Cooling Capacity at AS/NZS conditions: Entering Water Temperature 30 C; Entering Air Temperature 27 C D.B., 19 C W.B. 3 Heating Capacity (CW R version only) at AS/NZS conditions: Entering Water Temperature 21 C; Entering Air Temperature 21 C D.B. 4 SL measured to JIS 8616 (1 m from source) at nominal supply air flow, with 1 m insulated duct. 5 ressure Drops based on nominal water flow. 6 Reverse Cycle Series. Materials and specifications subject to change without notice due to the manufacturer s ongoing research and development programme. age 26 age 27
16 Vertical Three hase CW Specifications CW 0132 Model CW 0109 CW 0132 CW 0178 CW 0217 CW 0266 CW 0374 CW 0447 CW 0568 CW 0890 CW 1030 Capacity (Range) kw Nominal Cooling Capacity 2 (kw) Net Cooling Capacity (kw) Efficiency Cooling (EER/AEER) / / / / / / / / / / Heating Capacity 3 (kw) Efficiency Heating (C/AC) 3.98 / / / / / / / / / / Electric Heat ption (kw) Nominal Supply Air Flow l/sec Sound ressure Level 4 db(a) ower Supply 1 3 hase 400V 50Hz 3 hase 400V 50Hz Run Amps at Nominal Conditions / 4.5 / / 5.7 / / 8.1 / / 10.1 / / 9.8 / / 15.9 / / 21.8 / / 26.4 / / 45.9 / / 60.3 / 57.1 Heat Exchanger Tube/Tube Tube/Tube Water Flow l/sec Water ressure Drop ka / psi 27.6 / / / / / / / / / / 4.5 Water Connections Ø mm / BS 25 / 1" 32 / 1¼" 32 / 1¼" 38 / 1½" 38 / 1½" 51 / 2" 51 / 2" 51 / 2" 64 / 2½" 76 / 3 Dimensions (mm) Width Height Depth Weight (kg) Weight (excluding water) NTES: 1 Voltage fluctuation limits 3 hase models V.a.c. 2 Nominal Cooling Capacity at AS/NZS conditions: Entering Water Temperature 30 C; Entering Air Temperature 27 C D.B., 19 C W.B. 3 Heating Capacity (CW R version only) at AS/NZS conditions: Entering Water Temperature 21 C; Entering Air Temperature 21 C D.B. 4 SL measured to JIS 8616 (1 m from source) at nominal supply air flow, with 1 m insulated duct. 5 ressure Drops based on nominal water flow. 6 Reverse Cycle Series. Materials and specifications subject to change without notice due to the manufacturer s ongoing research and development programme. age 28 age 29
17 Sydney: (02) Newcastle: (02) Christchurch: (03) Townsville: (07) erth: (08) Jakarta: (62) Adelaide: (08) Launceston: (03) Singapore: (65) Brisbane: (07) Auckland: (09) Shanghai: (21) Melbourne: (03) Wellington: (04) Auckland (Head ffice and Manufacturing) Sydney (Australian Head ffice and Manufacturing) Branches Wellington, Christchurch, Brisbane, Melbourne, Adelaide, Singapore, Shanghai and Jakarta. Distributors North Queensland, erth, Launceston, Newcastle, Singapore, Shanghai, Beijing, Jakarta, Hong Kong, Sri Lanka, Mauritius, Bangalore, Bangkok, Hanoi, Cambodia, South acific Islands and Bangladesh /18 TEM
Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control
Cooling Capacity 3.5kW - 101.6kW Heating Capacity 4.4kW - 98.6kW Water-Cooled Air Conditioning Giving you complete control More than just another air conditioning company. We re dedicated to pioneering
More informationAir Cooled Packaged Units
H U M I D I T Y I N T E L L I G E N C E Heating Capacity 15kW - 186kW Cooling Capacity 15kW - 200kW HUMIDITY INTELLIGENCE Introducing Adaptive Intelligence into Air Conditioning Air Cooled Packaged Units
More informationTechnical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging
Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013
More informationCooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control
Cooling Capacity 1.0kW - 8.5kW Heating Capacity 1.0kW - 9.7kW Hitachi Inverter Wall Splits Air Conditioning Giving you complete control A smart choice. Temperzone is proud to distribute the Hitachi range
More informationDucted Split System Air Conditioners Technical Data
Technical Data ISDL 66, ISDL 87, ISDL 116 Cooling Capacity 6.7kW - 11.2kW Heating Capacity 6.2kW - 11.1kW Contents ISDL 66 116 KYX SERIES 3 General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant
More informationDucted Split System Air Conditioners Technical Data
Technical Data ISD 294, ISD 324 Cooling Capacity 27.9kW - 34kW Heating Capacity 28.2kW -32.2kW Contents ISD 294, 324 KYX SERIES General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant R410A
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationTechnical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw
Ducted Three Phase Packaged Air Conditioners Technical Data 96 RKTBG-P Plug Fan with High Efficiency EC Motor and High External Static Economiser Option TZT Controller & Digital Scroll Compressor for close
More informationMEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Packaged Roof Top Air Conditioners Product Review OPA-RK Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.6 kw 137 kw MEPS COMPLIANT INVERTER MODEL MODELS MARCH 2014
More informationTechnical Data Ducted Three Phase Split System Air Conditioner
ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED
More informationWater Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW
Water Cooled Units Technical Data HWP 370, 445 Cooling Capacity 36.6kW - 44.5kW Heating Capacity 34.9kW - 42.2kW Contents HWP 370, 445 General 3 Applications 4 Introduction 4 Features 5 Refrigerant 5 Efficient
More informationTechnical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw
Ducted Split System Air Conditioner Technical Data ISD 87KYX / OSA 87RKSH SEPARABLE INDOOR UNIT Optional SAT-3 or TZT-100 Room Temperature Controller High Efficiency EC Motor Extra Long Life Epoxy Coated
More informationTechnical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw
Ducted Split System Air Conditioner Technical Data ISD 184KY / OSA 184RKTV SEPARABLE INDOOR UNIT OPTION Optional SAT Controller High Efficiency EC Motor Extra Long Life Epoxy Coated Outdoor Coil Nominal
More informationTechnical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities
Ducted Vertical Packaged Air Conditioner/Heat Pump Technical Data, 1 Wide Ambient Capabilities Variable Capacity 2kW 12/16kW High Efficiency EC Plug Fan Versatile Configuration Including Controller & Digital
More informationADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE
ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE At ActronAir, we see air conditioning differently. Add-on air conditioning The leading Australian owned air conditioning brand, ActronAir
More informationTechnical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw
Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES
More informationEC Motor Fan Coil Units. IMD-Y Series l/s
EC Motor Fan Coil Units IMD-Y Series 45 235 l/s Temperzone s Fan Coil History Temperzone have been manufacturing chilled water fan coil units for more than 45 years. Company Profile Temperzone Limited
More informationHitachi Inverter Wall Split Air Conditioning
Cooling Capacity 2.5kW - 8.0kW Heating Capacity 3.2kW - 9.0kW Hitachi Wall Split Air Conditioning Giving you complete control Water-cooled Units Hitachi and Temperzone: Combining to offer New Zealand and
More informationOPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance
OPA 465 960 RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance 1. GENERAL Temperzone OPA Outdoor Air Cooled Packaged units. Follow these instructions to ensure the
More informationDUCTED WATER COOLED PACKAGED AIR CONDITIONERS HWP models (c/w UC8) Installation & Maintenance
DUCTED WATER COOLED PACKAGED AIR CONDITIONERS HWP models (c/w ) Installation & Maintenance 1. GENERAL 1.1 Introduction Follow these instructions to ensure the optimum performance, reliability and durability.
More informationTechnical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity
Modular Air Cooled Condensers Technical Data ACN Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 68 kw 155 kw MARCH 2010 ACN SERIES MODULAR AIR COOLED CONDENSERS General The ACN
More informationWater-cooled chillers with High Speed Centrifugal Compressors
Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationLeading edge Add-on cooling for ducted gas heating
Leading edge Add-on cooling for ducted gas heating Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. It is this commitment
More informationКомпрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.
1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become
More informationWhole of Home ADD ON. Add some cool comfort to your life. That s better. That s Actron.
Whole of Home Add some cool comfort to your life. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. Just Add On for the best summer ever The year 984 saw Advanced
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become
More informationultimate climate control and advanced energy efficiency THE ESP SERIES
ultimate climate control and advanced energy efficiency THE ESP SERIES art perform rm ener nergy smart energy performance smar t performance gy smar art performance rmance designed & built in australia
More informationWhat do I need for my bedroom?
What do I need for my bedroom? Whisper-quiet cooling and heating for smaller rooms Exceptionally designed for modern homes and lifestyles, our 2.5kW and 3.5kW inverter wall units are perfect for bedrooms,
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS
ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS CONTENTS Overview 2 Features & Benefits 3 Performance 4 Accent Pool Water to Water Heat Pumps Technical 5 Accent Hot Water Water to Water Heat Pumps Technical
More informationCOMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS
COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW ACKAGES ORIGINAL MANUFACTURED EUIMENT Commech Series New Models BA-509-2 AUS roduct Features The BITZER ComMech Series compact screw compressor pack
More informationINTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation
JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed
More informationESP PLATINUM CHANGING THE GAME FOR DUCTED AIR-CONDITIONING
ESP PLATINUM CHANGING THE GAME FOR DUCTED AIR-CONDITIONING ActronAir has been designing and building air conditioning systems, for Australia s unique and demanding conditions, since 194. The company s
More informationCommercial HERCULES. The brains and brawn redefining air conditioning efficiencies. That s better. That s Actron.
Commercial The brains and brawn redefining air conditioning efficiencies. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia
More informationLeading edge reverse cycle air conditioning. Ducted and ceiling cassette
Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The
More informationCOOLflow 4E PRODUCT RANGE
COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed
More informationPRODUCT RANGE: ROOFTOP PACKAGE
Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They
More informationHeat Pump Air Conditioning Systems
Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.
More informationRESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING
A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without
More informationRESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING
RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,
More informationItem No. (Standard/Opposite Hand) /
SPECIFICATIONS Model HWP 59RKS Item No. (Standard/Opposite Hand) 509-059-001 / 509-059-011 Cooling capacity (net) to AS/NZS 3823 T1 5.7 kw Heating capacity H1 5.4 kw Electrical input - cooling 1.6 kw Electrical
More informationPackaged Air Conditioning Custom Build Solutions
Packaged Air Conditioning Custom Build Solutions Packaged Airconditioning Units - PA Range custom build customer driven Custom Build Customisation of Temperzone packaged units provides a high degree of
More informationIndirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)
Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.
More informationChillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw
Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationAURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS
AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning
More informationYAH SERIES FAN COIL UNITS
YAH Series Fan Coil Units Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central air-conditioning systems. They are designed for fresh air units or to cool, heat,
More informationAURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS
AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning
More informationWater Cooled Air Conditioners Applications Manual
s Manual HWP-K UC8 Series Contents HWP-K UC8 SERIES Location & Acccess 3 Noise Considerations 4 Water Treatment for Systems using 5 Cooling Towers Water Loop & Unit Control 6 Selection of Balancing Valves
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More informationAIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU
ONLY PANASONIC GETS 5 STARS AGAIN, AGAIN & AGAIN AIR CONDITIONING AERO SERIES REVERSE-CYCLE INVERTER Reliability Functionality Ease of use Value for money After sales service Overall customer satisfaction.
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationIndirect Evaporative Air Conditioning
Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient
More informationFAN COIL UNITS. The optimal solution for limited space
FAN COIL UNITS The optimal solution for limited space CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationHybrid VRF Next Generation 2-Pipe Heat Recovery Systems
Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means
More informationEfficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES
Efficiency Vermont is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES
More informationOperating Performance
INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.
More informationWhen you have a Bonaire ducted gas heater installed, you won t know it is winter until you look out the window Ducted Gas Heating Range
When you have a Bonaire ducted gas heater installed, you won t know it is winter until you look out the window Ducted Gas Heating Range Welcome to Bonaire As one of Australia s leading heating and cooling
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationS Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance
HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 3 5 C K Series Size Type S Y D GENERAL
More informationDucted Air Conditioning
Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationAIR CONDITIONING REVERSE-CYCLE INVERTER
AIR CONDITIONING REVERSE-CYCLE INVERTER CLASS LEADING FEATURES FASTER COOLING The new Panasonic Thermal Enhancement Technology (P-TECh) enables the compressor to achieve maximum frequency in the shortest
More informationIntegrated VarIable refrigerant flow ahu/pau (r410a)
Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14
More informationImplementation of Energy Saving measures in Existing Buildings
Building Surveyors Conference on Building a Green and Sustainable Future Implementation of Energy Saving measures in Existing Buildings 5 September 2009 Energy Efficient / Environmental Friendly Products
More informationdesigned for air conditioning australian living
designed for air conditioning australian living ActronAir is Australian made for Australian conditions There s nowhere else in the world that s quite like Australia, and it takes an Australian air conditioning
More informationCaice Attenuator Selector - Specifier Edition
Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance
More informationTrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION
TrilliumSeries Condenser T A B L E O F C O N T E N T S 1 TRILLIUMSERIES CONDENSER 3 BENEFITS 8 MODES OF OPERATION 9 ENGINEERING DATA 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 12 CO
More informationIndirect Evaporative Air Conditioning
Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient
More informationDaikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel
Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent
More informationDucted Air Conditioning
Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple
More informationRotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives
Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives Reliability. Efficiency. roductivity. More Than 100 Years of Compressed Air Innovation Ingersoll Rand introduced its
More informationA GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA
A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet
More informationCommercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.
Commercial The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationNQ Series Portable Chillers
NQ Series Portable Chillers Electrical Components Mounted and Wired All electrical components and sensors are mounted, wired, and fully tested at the factory to reduce installation time and ensure the
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationResidential and Light Commercial Ductless Systems Catalog
Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage
More informationBraemar superior range of reverse cycle air conditioning
Braemar superior range of reverse cycle air conditioning Frank Seeley AM FAICD Founder and Executive Chairman. For more than 40 years, Seeley International has been creating world leading air conditioning
More informationAEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton
AEPT SERIES Multi-Position, Variable-Speed High-Efficiency Air Handler 2 and 5 Ton The AEPT air handler is compact for versatile upflow/downflow or horizontal multi-position installations and may be located
More informationDUCTED RANGE HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY
DUCTED RANGE A I R C O N D I T I O N I N G S O L U T I O N S HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu is a leading supplier
More informationAir Cooled Packaged Systems AIRAH Back to Basics
Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationINTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012
HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationBlack Diamond Series. The New Standard in Personalised Comfort and Style. Superior Performance Made for New Zealand Conditions
Black Diamond Series The New Standard in Personalised Comfort and Style Superior Performance Made for New Zealand Conditions Introducing the Black Diamond Series The Black Diamond Series sets the new standard
More informationAIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw
PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationCaice Attenuator Selector - Specifier Edition
Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance
More informationCommercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.
Commercial The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced
More information30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +
Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new
More informationEC Motor Fan Coil Units. IMDL-Y Series l/s
C Motor Fan Coil Units IMDL-Y Series 00 700 l/s Temperzone s Fan Coil History Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products
More informationEco Compact Series GAS HEAT PUMP
Eco Compact Series GAS PUMP CREATING AIR-CONDITIONED COMFORT GREAT COMFORT, LOW SOUND LEVELS Natural gas provides excellent power and performance. That is why Yanmar gas heat pump [GHP] s are the ideal
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationRemote Air Cooled Condensers C2 Series
Remote Air Cooled Condensers C2 Series High Fan Speed Capacity 236kW Low Fan Speed Capacity 1740kW 180kW 1257kW Innovative Heat Transfer Solutions Issue date 04/14 APPLICATION BENEFITS / FEATURES HIGH
More information