1 Water Softener Installation Guide Effective for all Softeners from our Range Planning Your Installation Always observe the water byelaws. Ensure there is only one rising main, that you have allowed space for access to the unit for salt filling and possible maintenance in the future. Check the water pressure; locate the rising main ( stop cock), a drain facility and a power supply. Siting the Softener Where possible, this should be close to the rising main. Take care to allow hard water take off points for a drinking water facility and /or an outside tap. For easy DIY installation we recommend the fitting of a hard or filtered water kit. If the Stopcock is located in an inconvenient position to create a hard water supply we recommend the fitting of an reverse osmosis system. The distance between the drain and the Softener should be as short as possible. Ensure that both the drain and overflow are not subject to freezing or over 120 F. If siting the softener within a cupboard ensure that the base is adequately supported. If the softener is being installed within your loft etc, it is recommended to house the softener within a 25-gallon tank and insulate well. The overflow on the tank should be below the softener overflow and be a minimum of ¾ in size. Typical Softener installation Valve configuration Non Return Valve In single dwellings a single check valve should be fitted. This is supplied with our installation kits that can be ordered separately. Check list Dependant upon your installation you may need to purchase 2 T valves if you purchased a fitting kit all other valves required would be included. Check that you have ordered the correct fitting kit for your installation. Combi boilers require a Combi Kit, Pressurised system require a 22mm Fitting Kit. Water Pressure Test It is important that a pressure check is carried out. Low and high water pressure can result in either damage to, or failure of the softener. Although the softener is tested to a pressure of 8 bar we recommend the fitting of a pressure limiter should your pressure exceed 5 bar (70 psi) we also recommend that any water appliance should be fitted with a leak controller. Before starting installation of the valves ensure that the stopcock is in the closed position. DO NOT ADJUST THE RED BAR THIS IS ONLY TO BE USED OUR BY ENGINEERS
2 Connecting to the softener Once you have completed the installation of the valves put the valves into the positions as shown Softener inlet and outlet closed bypass valve open (if you have also installed an hard water supply kit and have only so far installed the valve also make sure that this is closed) You can now safely return the stop cock to the open position. Using the hoses provided (if you purchased a fitting kit) connect the straight end of the hoses having first inserted the washer provided to the softener inlet and outlet valves. Connect the angled end to the softener.the softener inlets and outlets should be indicated either with the words inlet or outlet or with an embossed directional arrow on the softener tails. Normally the softener tails are in a configuration of three with the centre normally being the waste outlet. Waste Pipe Installation All softeners are provided with a waste hose on some of our units this is preinstalled to the softener. Should this not be the case on your machine use the connection fitting at the end of the supplied flexible pipe to connect to the softener drain connection. Run the drain hose to either an up stand or an outside drain. A minimum air gap of 20mm must exist at the end of the drain line. Softened water will have no adverse effect on a septic tank. If you need to extend the drain hose this can be done by connecting to a 15mm copper tube for a maximum run of 8 meters with a minimum daytime pressure of 40psi. Ensure that the drain hose is not kinked in any way as this will lead to an overflow of the machine. The drain hose can run up hill to a maximum of 3 feet with a minimum pressure of 40psi. Overflow Connection The hose from the overflow should be cut from the drain hose provided. The overflow connection is the white ½ hose spigot on the rear or side of the cabinet. No clip is required for this connection. The overflow must be run downhill through an outside wall without kinks or restriction. It is recommend the overflow hose be visible when it exits the Outside wall. Electrical connection Connect the transformer provided to a continuous electrical connection supply with the power off. Plug the flying lead from the transformer into the electrical connection on the controller (see programming instructions for location of individual units). Ensure the flying lead cannot get caught on the camshaft or any moving parts on the machine Preparing the softener to go into service Now that all of the connections have been completed it is advisable to put approximately 5 litres of water into the brine tank. You may also at this point but a quantity of salt into the tank. Do not allow the salt level in the brine tank to exceed the height of the overflow. Should you require a salt supply Visit our Website. The amount of salt used will depend upon the type of machine.you should never let the brine tank become completely empty of salt and it is advisable to check the salt levels on a weekly basis until a usage pattern has been established. Setting the machine to service To set the machine to service simply alter the position of the inlet and outlet valve and turn the bypass valve to the off position. It is recommended that this procedure is completed in the following order. 1, Turn the Softener inlet valve to the on position 2, Turn the bypass valve to the off position. Allow approximately five minutes to allow the incoming water to build a level of pressure before completing step 3. 3, Turn the Softener outlet valve to the on position. You should now complete any programming instructions that apply to your particular machine and perform a manual regeneration. A manual Regeneration is performed at this stage to allow you to confirm that the unit has no leaks from the installed valves and the Waste runs free. This regeneration will also assist in clearing any potential air locks that may be present within the system. The regeneration will also reset any internal meter or timer devices that dictate the frequency of the regeneration cycle. Your machine should now be supplying your property with soft water. If you find that the water feels too soft for you. It is possible to dilute the softness by slightly opening the bypass valve and allow some hard water to blend with the soft.
3 Control Valve Air Check Check Ball Female Elbow Brine Line Figure 10 - Control Valve 5. Put into operation. 3/4 fill brine tank with tablet salt a. Open water supply valve slowly to full open position. b. Carefully advance indicator knob COUNTERCLOCKWISE to center of FAST RINSE/REFILL position and hold there until air check (Figure 10) fills with water and water starts to flow through brine line into brine tank. Do not run for more than two minutes. c. Advance indicator knob COUNTERCLOCKWISE until arrow points to the center of the BRINE/SLOW RINSE position. d. With the conditioner in this position, check to see if water is being drawn from the brine tank. The water level in the brine tank will recede very slowly. Observe for at least three minutes. If the water level does not recede or goes up, or if air enters the transparent air check chamber and the ball falls and seats, reference Troubleshooting section. e. Advance indicator knob COUNTERCLOCKWISE to CONDITIONED WATER. f. Run water from a nearby faucet until the water is clear and soft.
4 400 Series Control Settings 440i Control Timer Day Arrow Skipper Pins Skipper Wheel Indicator Knob Timer Locking Pin Time Arrow Timer Knob Programming Figure Set days of regeneration on skipper wheel (Figure 11). Pull all skipper pins outward (away from control). Rotate skipper wheel until day arrow points to current day or number 1. Depress skipper pin(s) at day(s) for which regeneration is desired. 2. Set the time of day. Grasp timer knob and pull outward. Rotate in either direction until the timer arrow points to the actual time of day. Release timer knob. Note: With the time of day properly set, the conditioner will regenerate at about 2:30 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set current time-of-day accordingly (e.g., to have the unit regenerate at 4:30 a.m. two hours later set the clock two hours earlier than the actual time of day.) Note: The Timer Locking Pin should always be horizontal (Figure 11) during operation.
5 460i Control Meter Water Flow Indicator PM Indicator Hour Time Display Access Door Raised Tab Indicator Knob Transformer Plug Timer Receptacle Locking Pin Time Set Button Jumper Spare Jumper Figure 12 Programming Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control. Open the access door by pushing the raised tab on the door toward the left while pulling the tab out (Figure 12). Time of Day Setting With the jumper on the set of pins next to the word TIME (Figure 13), set the time of day to the closest hour by pressing the black TIME SET button. PM hours are indicated by a light next to the letters PM on the display window. Note: The use of a small needle-nose pliers will aid in moving the jumper. Note: The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set the current time of day accordingly (e.g., to have the unit regenerate at 4:00 a.m. two hours later set the clock two hours earlier than the actual time of day). Note: The Timer Locking Pin should always be horizontal (Figure 12) during operation.
6 Hardness Setting Move the jumper to the set of pins next to the word HARDNESS (Figure 14). Press the black TIME SET button until the hardness of the incoming water supply is displayed. The hardness range is from 1 to 99 grains per gallon. To change water hardness stated in parts per million (PPM) to grains per gallon (GPG) use this formula: Hardness Figures can be obtained from your water provider Parts per Million = 14.1 Grains per Gallon, We Also sell hardness Test Kits Figure 13 Figure 14 Figure 15 Capacity Setting Already Factory Set. Note: A spare jumper is located on the bottom set of pins. In the event that the hardness setting must be changed, simply follow the appropriate steps described above. Calendar Override Setting 1. Disconnect power. 2. Place jumper on Pin A and reconnect power. 3. Move jumper to Pin B. A zero will appear, indicating zero days of calendar override. All 460i controllers are preprogrammed in this manner at the manufacturer.
7 4. Depress the black TIME SET button. The numbers will roll from 0 to 15. Release the switch at the desired number of days for the calendar override. For example, releasing the switch at 10 would program a 10-day calendar override. 5. Disconnect power. 6. Place jumper back on TIME and reconnect power. 7. The calendar override program is maintained during power outages by the NOVRAM circuitry. 8. To remove the calendar override, follow the same steps above and program back to 0. Guest Cycle (Manual Regeneration) When abnormally high water usage exhausts your water conditioner s capacity ahead of schedule, an extra regeneration can be achieved. Depress the indicator knob on the 440i (Figure11) with a wide-blade screwdriver and turn COUNTERCLOCKWISE to START to initiate a regeneration. For the 460i, simply depress the indicator knob (Figure12). It will take a few minutes for regeneration to start. A normal regeneration will take approximately two hours. Figure 13
8 Preventive Maintenance Inspect and clean brine tank and screen filter on end of brine pickup tube once a year or when sediment appears in the bottom of the brine tank. Clean injector screen and injector once a year: 1. Unplug the wall-mount transformer. 2. Shut off water supply or put bypass valve(s) into bypass position. 3. Relieve system pressure by opening valve No. 5 (at rear) with a screwdriver. 4. Using a screwdriver, remove injector screen and injector cap (Figure 16). 5. Clean screen using a fine brush. Flush until clean. 6. Using a needle-nose pliers, pull injector straight out. 7. Flush water into the injector screen recess of the valve body to flush debris out through the injector recess. 8. Clean and flush the injector. 9. Lubricate the O-rings on the injector, injector cap and injector screen with silicone lubricant. 10. Reinstall the injector, injector cap and injector screen. See IMPORTANT note. 11. Plug the wall-mount transformer into outlet; reset time of day. 12. Slowly open water supply valve or return bypass valve(s) to the not in bypass position. IMPORTANT: Do not overtighten the plastic cap. Seat the cap lightly into position. Overtightening may cause breakage of the plastic cap that may not be immediately evident. Figure 16
9 Troubleshooting The technology upon which the Series 255 control is based is well established and proven in service over many years. However, should a problem or question arise regarding the operation of the system, the control can be very easily serviced. The control module can be quickly replaced or adjustments can be made at the installation. We recommend that you contact your local professional water treatment dealer for most concerns. For parts mentioned, refer to exploded views in the Replacement Parts section of this manual. IMPORTANT: Service procedures that require the water pressure to be removed from the system are marked with a! after the possible cause. Refer to Preventative Maintenance section for instructions. Common Problem Possible Cause Solution 1. Brine tank overflow. 2. Flowing or dripping water at drain or brine line after regeneration. 3. Hard water leakage after regeneration. a. Uncontrolled brine refill flow rate. b. Air leak in brine line to air check. c. Drain control clogged with resin or other debris. a. Valve stem return spring weak. a. Improper regeneration. b. Leaking of external bypass valve. c. O-ring around riser pipe damaged. a. Remove brine control to clean ball and seat. b. Check all connections in brine line for leaks. Refer to instructions. c. Clean drain control. a. Replace spring. (Contact a. Repeat regeneration after making certain correct salt dosage was set. b. Replace bypass valve. (Contact c. Replace O-ring. (Contact
10 4. Control will not draw brine. a. Low water pressure. b. Restricted drain line. c. Injector plugged! d. Injector defective! e. Valve disc 2 and/or 3 not closed. f. Air check valve prematurely closed. a. Make correct setting according to instructions. b. Remove restriction. c. Clean injector and screen. d. Replace injector and cap. (Contact e. Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace if needed. (Contact f. Put control momentarily into brine refill. Replace or repair air check if needed. (Contact
11 255/440i Troubleshooting Problem Possible Cause Solution a. Transformer or motor not a. Connect power. connected. 1. Control will not regenerate automatically. b. Defective timer motor. c. Skipper pins not down on timer skipper wheel. d. Binding in gear train of timer. b. Replace motor. (Contact c. Depress pins for days regeneration required. d. Replace timer. (Contact 2. Control regenerates at wrong time of day. 3. Control will not draw brine. a. Timer set incorrectly. a. Correct time setting according to instructions. a. Low water pressure. b. Restricted drain line. c. Injector plugged. d. Injector defective. e. Air check valve closes prematurely. f. Timer locking pin not horizontal. a. Set pump to maintain 20 psi at softener. b. Change drain to remove restriction. c. Clean injector and screen. d. Replace injector. (Contact e. Put control momentarily into brine/slow rinse. Replace or repair air check if needed. (Contact f. Turn to horizontal position. (Contact 4. System using more or less salt than salt dial setting. 5. Intermittent or irregular brine draw. 6. No conditioned water after regeneration. a. Foreign matter in controller causing incorrect flow rates. b. Defective controller a. Low water pressure. b. Defective injector. a. No salt in brine tank. b. Injector plugged. c. Air check valve closes prematurely. a. Remove brine control and flush out foreign matter. Manually position control to brine/slow rinse to clean controller (after so doing position control to "purge to remove brine from tank). b. Replace brine control. (Contact a. Set pump to maintain 20 psi at softener. b. Replace injector. (Contact a. Add salt to brine tank. b. Clean injector and screen. c. Put control momentarily into brine/slow rinse. Replace or repair air check if needed. (Contact
12 Problem Possible Cause Solution 7. Control backwashes or purges at excessively low or high rate. 255/460i Troubleshooting 1. Clock does not display time of day. a. Incorrect drain controller used. b. Foreign matter affecting controller operation. a. Replace with correct size controller. (Contact b. Remove drain controller and clean ball and seat. Problem Possible Cause Solution a. Transformer cord a. Connect power. unplugged. 2. Clock does not display correct time of day. 3. Time display continues to advance. 4. Time display shows something other than time of day. 5. No water flow display when water is flowing. b. No electric power at outlet. c. Defective transformer. d. Defective circuit board. a. Outlet operated by switch. b. Incorrect voltage or frequency (Hz). c. Power outages. b. Repair outlet or use working outlet. c. Replace transformer. (Contact d. Replace timer. (Contact a. Use outlet not controlled by switch. b. Replace timer with one of correct voltage and frequency (Hz). (Contact c. Reset clock. a. Defective time set switch. a. Replace timer. (Contact a. Electrical interference. b. Defective circuit board. a. Bypass valve in bypass. b. Meter probe disconnected or not fully connected to meter housing. c. Restricted meter turbine rotation due to foreign material in meter! d. Defective meter probe. e. Defective circuit board. a. Disconnect power to unit. Restore power and reset time of day display. b. Replace timer. (Contact a. Shift bypass valve to not-inbypass position. b. Fully insert probe into meter housing. c. Remove meter housing, free up turbine and flush with clean water. Turbine should spin freely. If not, replace meter. (Contact d. Replace timer. (Contact e. Replace timer. (Contact
13 Problem Possible Cause Solution a. Power outages. 6. Control regenerates at wrong time of day. 7. Timer stalled in regeneration cycle. 8. Continuous regeneration. Camshaft does not stop at the end of regeneration. 9. Control will not regenerate automatically or when button is pressed. b. Clock set incorrectly. a. Motor dead. b. Motor runs backward. c. No electric power at outlet. d. Broken gear. e. Defective switch. f. Air leak in brine connections. g. Binding of camshaft. h. Water pressure greater than 125 psi (8.6 bar) during regeneration! i. Defective circuit board. a. Broken switch actuator on gear. b. Defective switch. a. Electric cord or transformer unplugged. b. No electric power at outlet. c. Defective motor. d. Broken gear. e. Binding in gear train. f. Defective switch. a. Reset clock to correct time of day. b. Reset clock to correct time of day. a. Replace timer. (Contact b. Replace timer. (Contact c. Repair outlet or use working outlet. d. Replace timer. (Contact e. Replace timer. (Contact f. Check all junction points and make appropriate corrections. g. Remove foreign object obstruction from valve discs or camshaft. h. Install pressure regulator. i. Replace timer. (Contact a. Replace timer. (Contact b. Replace timer. (Contact a. Connect power. b. Repair outlet or use working outlet. c. Replace timer. (Contact d. Replace timer. (Contact e. Replace timer. (Contact f. Replace timer. (Contact
14 Problem Possible Cause Solution a. Same as Item Control will not regenerate automatically but will regenerate when button is pressed. 11. Run out of soft water between regenerations. 12. Brine tank overflow. a. If water flow display is not operative, refer to Item 5. b. Defective circuit board. c. Incorrect hardness and capacity settings. a. Improper regeneration. b. Incorrect salt setting. c. Incorrect hardness or capacity settings. d. Water hardness has increased. e. Restricted meter turbine rotation due to foreign material in meter! a. Brine valve disc 1 being held open by foreign matter. b. Uncontrolled brine refill flow rate. c. Valve disc 2 not closed during brine draw causing brine refill. d. Air leak in brine line to air check. e. Improper drain control for injector. f. Drain control clogged with resin or other debris. b. Replace timer. (Contact c. Set to correct values. See Programming section. a. Repeat regeneration, making certain that correct salt dosage is used. b. Set salt control to proper level. See salt setting chart. c. Set to correct values. See Programming section. d. Set hardness to new value. See Programming section. e. Remove meter housing, free up turbine and flush with clean water. Turbine should spin freely; if not, replace meter. (Contact a. Manually operate valve stem to flush away obstruction. b. Remove variable salt controller to clean it and the ball. c. Flush out foreign matter holding disc open by manually operating valve stem. d. Check all connections in brine line for leaks. Refer to instructions. e. Too small of a drain control with a B or C injector will reduce draw rates. Reference Pressure Graphs. f. Clean drain control.
15 Problem Possible Cause Solution a. Inaccurate setting. a. Make correct setting. b. Foreign matter in controller causing incorrect flow rates. 13. System using more or less salt than salt control is set for. 14. Intermittent or irregular brine draw. 15. No conditioned water after regeneration. c. Defective controller. a. Low water pressure. b. Defective injector! a. Unit did not regenerate. b. No salt in brine tank. c. Plugged injector! d. Air check valve closed prematurely. b. Remove variable salt controller and flush out foreign matter. Manually position control to brine draw to clean controller (after so doing, position control to purge to remove brine from tank). c. Replace defective part. (Contact a. Set pump to maintain at least 20 psi (1.38 bar) at softener. b. Replace both injector and injector cap. (Contact a. Check for power. b. Add salt to brine tank. c. Remove injector and flush it and injector screen. d. Put control momentarily into refill to free air check. Replace or repair air check if needed. (Contact Valve Specifications Working Pressure psi ( bar) Standard 12 Volt Transformer Input Electrical Rating V 60 Hz Optional 12 Volt Transformer Input Electrical Rating V 50 Hz, 230V 50 Hz, 230V 60 Hz, 100V 60 Hz, 100V 50 Hz Operating Ambient Temperature F to 120 F (1 C to 49 C) Operating Water Temperature F to 100 F (1 C to 38 C) For service or parts, please contact your local professional water treatment dealer.for salt call Copyright 2004 GE Water Technologies Printed in the USA P/N Rev. I
Autotrol Brand Performa Valve / 400 Series Controls
Autotrol Brand Performa Valve / 400 Series Controls Water Conditioning Control System Home Owner Installation, Operation, and Maintenance Manual For sales or service questions please contact your local
More informationAutotrol Performa FA Valve
Autotrol Performa FA Valve With 400 Series Control Water Conditioning Control System Dealer Installation, Operation, and Maintenance Manual Table of Contents Installation................................
More informationAutotrol Brand 255 Valve / 400 Series Controls
Autotrol Brand 255 Valve / 400 Series Controls Water Conditioning Control System Home Owner Installation, Operation, and Maintenance Manual For sales or service questions please contact your local dealer:
More informationWhat to expect from your water softener
What to expect from your water softener All water softeners work on the same basic principal. Hard water flows through a bed of resin and the calcium and magnesium, the minerals that are responsible for
More informationAutotrol Performa Valve
Autotrol Performa Valve With 400 Series Control Water Conditioning Control System Dealer Installation, Operation and Maintenance Manual Table of Contents Installation................................ Location
More informationAutotrol Performa Valve
Autotrol Performa Valve With 400 Series Control Water Conditioning Control System Dealer Installation, Operation and Maintenance Manual Table of Contents Installation................................ Location
More informationAutotrol 255 Valve / 400 Series Controls
Autotrol 255 Valve / 400 Series Controls Water Conditioning Control System Home Owner Installation, Operation and Maintenance Manual For sales or service questions please contact your local dealer: Your
More informationAutotrol Performa Ultra. Electronic Control System Operation and Maintenance Manual
Autotrol Performa Ultra Electronic Control System Operation and Maintenance Manual Table of Contents Performa Ultra........................... 3 Electronic Demand System................. 3 Special Features
More informationSeries 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual
Series 255 Valve / 460i Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Introduction............................... 2 Series 255/460i Demand Control System
More informationAutotrol Performa Valve with 400 Series Control Water Conditioning Control System
Autotrol Performa Valve with 400 Series Control Water Conditioning Control System Service Manual 460TC BRINE/ SLOW RINSE DAYS CLOCK BACKWASH FAST RINSE/ REFILL CONDITIONED WATER MANUAL REGENERATION: PRESS
More information541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.
541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...
More informationInstallation, Commissioning, Programming & User Information For Water Softener Models: SF 10 Litre Timed & SF 12 Litre Metered
Installation, Commissioning, Programming & User Information For Water Softener Models: SF 10 Litre Timed & SF 12 Litre Metered October 2003 Part# SFINST These instructions are designed to give you the
More informationAUTOMATIC CARBON FILTER INSTALLATION & OPERATING INSTRUCTIONS
AUTOMATIC CARBON FILTER INSTALLATION & OPERATING INSTRUCTIONS Model: AFC09-263 Serial No: Manufacturer and Supplier of FILTRATION & WATER TREATMENT PRODUCTS for commercial, industrial and residential application
More informationDO NOT RETURN WATER SOFTENER TO STORE
1 DO NOT RETURN WATER SOFTENER TO STORE If you have any questions or concerns when installing, operating or maintaining your water softener or if there are any missing parts or damage, call our toll free
More informationWATER SOFTENER WITH 12 DAY SERIES TIMER CONTROL INSTALLATION & OPERATING INSTRUCTIONS. Serial No :
WATER SOFTENER WITH 12 DAY SERIES TIMER CONTROL INSTALLATION & OPERATING INSTRUCTIONS Model : Serial No : AS0922-940.. Manufacturer and Supplier of FILTRATION & WATER TREATMENT PRODUCTS for commercial,
More informationSpectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents
Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.
More information1850 Series TRIPLE TREAT Operation Manual
1850 Series TRIPLE TREAT Operation Manual BRINE TANK RESIN TANK CARBON TANK System shown with optional tank jackets. Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings
More informationOwner's Manual. WS Series. Water Softener
Owner's Manual WS-165-150 Series Water Softener Table of Contents WHAT'S INCLUDED 3 OPERATING CONDITIONS 4 ASSEMBLY INSTRUCTIONS 6 FLUSHING THE WATER LINES 13 MASTERPROGRAMMING 14 PROGRAMMING KEYAND GENERAL
More informationNovoSoft 465 Series SIM Water Softener Operation Manual
NovoSoft 465 Series SIM Water Softener Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF
More informationGRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION
GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION WATER SOFTENER: The Water Softener requires a 120VAC 2 AMP electrical service and the Water lines in and out need to be sized to the Softener.
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationOwner s Manual / 5600 Econominder
5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job
More informationPlumbline 1000 Series Timered Softeners Owners Manual Water Softener Models
Plumbline 1000 Series Timered Softeners Owners Manual Water Softener Models PS1000T PS1500T Table of Contents How to Use Soft Water 3 Product Line Overview 5 System Operation 6 System Maintenance and Install
More informationPS12 12 day Autotimer water softener
PS12 12 day Autotimer water softener PLUMBSOFT PS12 AUTOTIMER WATER SOFTENER PROGRAMMING & INSTALLATION INSTRUCTIONS Effective October 2013. Thank you for choosing our water softener. Please read the following
More information5700-E Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationPlumbline 2000 Series Metered Softeners Owners Manual Water Softener Models
Plumbline 2000 Series Metered Softeners Owners Manual Water Softener Models PS2000M PS2500M PS2700M PS2900M Table of Contents How to Use Soft Water 3 Product Line Overview 5 System Operation 6 System Maintenance
More informationTITAN VI High Efficiency Water Conditioner Installation and Operation Manual
TITAN VI High Efficiency Water Conditioner Installation and Operation Manual Manufacturer s Warranty Holts Water Conditioning 369 South Mountainway Drive Orem, UT 84058 801-426-9243 To the original purchaser,
More informationMetermatic Water Softener. Operation Manual
Metermatic Water Softener Operation Manual Page 5 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly for your guarantee
More informationTITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual
TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual TITAN VI Pro-Max Manufacturer s Warranty Holts Water Conditioning 369 South Mountainway Drive Orem, UT 84058 801-426-9243
More informationFully Automatic Water Filters
INSTALLATION INSTRUCTIONS Fully Automatic Water Filters INSTALLATION INFORMATION Model No. Unit Date Code Date Installed WATER ANALYSIS RECORD Hardness GPG Sulfur PPM Iron PPM ph Manganese PPM Tannins
More informationRIVERSOFT Water Softener System
RIVERSOFT Water Softener System Operations manual MODELS: RIVERSOFT 4 - RIVERSOFT 8 - RIVERSOFT 16 - RIVERSOFT 30 RiverSoft Demand Water Softener Installation and Operating Instructions TABLE OF CONTTS
More informationWATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS. Serial No :
WATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS Model : Serial No : AS1375MP-960.. Manufacturer and Supplier of FILTRATION & WATER TREATMENT PRODUCTS for commercial, industrial
More informationRecord of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location,
Record of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location, Plumbing Setup, Control Valve Installation Instructions 5
More informationWhirlpool. Model WHES40. Model WHES44. Model WHESCS. Water softener. Installation and operation manual * How to install, operate
Whirlpool Model WHES40 Model WHES44 Model WHESCS Water softener Installation and operation manual * How to install, operate and maintain your Demand Controlled Water Softener Our industry refers to this
More information2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit
00c WATER SOFTENER INSTALLATION INSTRUCTIONS visit www.kinetico.co.uk Safety Information Read all steps, guides and rules carefully before installing and using the Kinetico softener. Check your local building
More informationOWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters
OWNER S MANUAL Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters Congratulations! You ve selected our Premium Series Two Tank 1-PLUS-1 water conditioner and whole house filter for
More informationWater Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves
Water Softener & Single Tank Triple Treat System Installation Overview Using 1850 Metered Valves System Installation CAUTION: Do not use systems on untreated well water that is microbiologically unsafe.
More informationThis unit is superb for commercial applications where soft water is required 100% of the time.
Model 9000 water softener Rayne Infinity Water Softener This image portrays the locations the 9000 water softner unit is best suited; a car wash; laundry; motel and restaurants. This model 9000 water softener
More information6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.
6700 Valve Downflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #51431 Rev. 11/08 US Performance and Specifications Downflow Capacity at Various Salt Dosages
More informationUser Manual AF-30-VT
www.aquafilter.com User Manual AF-0-VT 1. Functions & Features...4 2. Operation...4. Cautions...4 4. Technical information...5 5. The bypass valve...5 6. Controller Operation Instruction...5 7. Inquiring
More informationWS1 Greensand Installation & Start Up Guide
WS1 Greensand Installation & Start Up Guide Thank you for purchasing a WS1 Water System for the removal of iron, manganese and hydrogen sulphide gas. With proper installation and a little routine maintenance
More information6700XTR Valve Downflow
6700XTR Valve Downflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #51545 Rev. 11/08 US Performance and Specifications Downflow Capacity at Various Salt
More informationFully Automatic Water Softeners
OWNERS GUIDE TO INSTALLATION AND OPERATION Fully Automatic Water Softeners FW0782 0211 Supersedes 0410 Models S15DC29DR and S15DC39DR SAFETY INFORMATION Read the instructions carefully and learn the specific
More informationInstallation & Service Manual
Installation & Service Manual Table of Contents Unpacking & Inspection... 2 Basic Guidelines... 2 Specifications... 3 Before Starting Installation Where to install the filter... 4 Tools, pipe, fittings
More information5900S Softener Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900S Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationFleck 2510 Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationThis material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.
This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected. For further questions contact Glass Water Systems or
More informationCONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5
CONTENTS Page Contents 1 Introduction, features and benefits 2 PART ONE Overview of the softening process Installation and operating considerations Installation layout PART TWO Installing your water softener
More informationMP-MBA-45T-1/60T-1 / 75T-1
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-45T-1/60T-1 / 75T-1 with the 268/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description
More informationEconoflo SXT Automatic Meter Initiated Water Softener
Econoflo SXT Automatic Meter Initiated Water Softener Operating and Maintenance Manual Page 5 of this manual contains important maintenance procedures for the continued proper operation of your unit. These
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 1650 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationE 3. Owner s Manual. Manufactured by: HELLENBRAND, INC. Phone: Fax Web:
E 3 Owner s Manual Manufactured by: HELLENBRAND, INC. Phone: 608-849-3050 Fax 608-849-7398 Web: www.hellenbrand.com Email: info@hellenbrand.com 2011 This owner s manual is designed to assist owners and
More information7000 Meter Initiated Valve
7000 Meter Initiated Valve Water Softener Operation Manual Read all instructions carefully before operation. #51400 Rev. 2/09 Performance and Specifications Item Model Capacity at regeneration salt levels
More informationMASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech February 2010 Table of Contents Page No. Topic Description
More informationINSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+
INSTALLATION MANUAL ESM9+ / ESM+ / ESM5+ THANK YOU Thank you for choosing a water softener from EcoWater. With over 80 years experience we have manufactured your new water softener from quality corrosion
More informationINSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS
INSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS ABSOLUTE MAXIMUM TEMPERATURE 60 C Before commencing the installation, ensure that you read these instructions
More informationInstallation Instructions & Owner's Manual. IM & INT Series
Installation Instructions & Owner's Manual IM & INT Series 12630 US Highway 33 N. Churubusco, IN 46723 Phone: (260) 693-1972 Fax: (260)693-0602 www.sterlingwatertreatment.com TABLE OF CONTENTS: Preinstallation
More information6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.
6700 Valve Upflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #57341 Rev. 11/08 US Performance and Specifications Upflow Capacity at Various Salt Dosages
More informationHD / HDL Valves & Systems Service Manual
Innovative Solutions for Your Water HD / HDL Valves & Systems Service Manual Hankscraft Runxin, LLC 300 Wengel Drive Reedsburg, WI 53959 608.524.9465 sales@hrh2o.com hrh2o.com 2 Table of Contents 1. Introduction...
More informationClean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Tannin Filter Installation & Startup Guide For Tannin Filters with Vortech Distributor Screen Thank you for purchasing a Clean Water System! With
More informationSERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55
SERVICE MANUAL WS-55 Hobart Compact Water Softeners Installation Instructions WS-55 - NOTICE - This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by those
More informationFLECK 3200 SERIES ELECTROMECHANICAL TIMER OWNER S MANUAL
FLECK 3200 SERIES ELECTROMECHANICAL TIMER OWNER S MANUAL waterpurification.pentair.com FEATURES OF YOUR WATER CONDITIONING SYSTEM Congratulations on the purchase of your new water treatment system featuring
More informationFleck 2510 Softener Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationFLECK 5600 WATER SOFTENER INSTALLATION
FLECK 5600 WATER SOFTENER INSTALLATION Discount Water Softeners recommends using a licensed plumber to install your water softener. The following installation instructions are for use with the water softener
More informationFULLY AUTOMATIC WATER SOFTENER
OWNERS GUIDE TO INSTALLATION AND OPERATION Section: 6.10.130 FM2035 0302 Supersedes 0102 FULLY AUTOMATIC WATER SOFTENER MODEL 340 SAFETY INFORMATION Read the instructions carefully and learn the specific
More informationFleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:
Installation Guide Before you assemble your new system, be sure that the following conditions have been met for placement of your softener: Getting Started Level, firm surface, such as concrete, on which
More information6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09
6700XTR Upflow Valve Water Softener Operation Manual Read all instructions carefully before operation. #51548 Rev. 2/09 Performance and Specifications Item Model Capacity at regeneration salt levels Service
More informationSanitizer Series. Water Conditioners
Sanitizer Series Water Conditioners TABLE OF CONTENTS Installation Instructions..........................................3-4 Start-up Procedures.............................................5-6 Programming
More informationTable of Contents. List of Figures
1 P a g e Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9 Feed Water Connection....10
More informationTotalCare, CareSoft Elite CareSoft Pro. and. Series. Water Softeners and Conditioners. For Models: TC1 TC2 CSE CSERC CSP CSPRC
TotalCare, CareSoft Elite CareSoft Pro Series Water Softeners and Conditioners and For Models: TC TC2 CSE CSERC CSP CSPRC For Cabinet Models: CSEC CSPC TABLE OF CONTENTS Preinstallation Instructions for
More informationAUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL
AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND FITTINGS
More information565 TLC Softener & Tannins Reduction System
565 TLC Softener & Tannins Reduction System Owners Manual 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified
More informationFleck 7000 Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationEvolve Series. Water Softeners and Conditioners. For Models: EV1 EV2 EVR EVRC EVRS EVRCS. For Cabinet Models: EVC EVCS
Evolve Series Water Softeners and Conditioners For Models: EV EV EVR EVRC EVRS EVRCS For Cabinet Models: EVC EVCS TABLE OF CONTENTS Pre-Installation Instructions for Dealers... Bypass Valve.... Installation....5
More informationCWS Plus Sediment Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com CWS Plus Sediment Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationEffective April 14. Installation Date:..
Fully Automatic Water Softener Programming and Installation Instructions for Metered (M) softeners. Please note the GS6000 is only available as a meter control softener and does not have a (M) within the
More informationWater Softener. Operating Manual
Water Softener Operating Manual WARNING AND SAFETY INSTRUCTIONS This water softener complies with all relevant local and national safety requirements. Improper use will invalidate your manufacturers warranty
More informationProFlo SXT Valve Downflow / Upflow
ProFlo SXT Valve Downflow / Upflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #54719 Rev. 1/09 US Performance and Specifications Downflow Upflow Capacity
More informationOwner s Manual. 12 Volt Electronics. AMERICAN AQUA Saline, MI (734) Howell, MI (517) Adrian, MI (517)
12 Volt Electronics Owner s Manual 2001-2009 AMERICAN AQUA Saline, MI (734)429-5070 Howell, MI (517)546-1750 Adrian, MI (517)265-8000 www.americanaqua.com This owner s manual is designed to assist owners
More informationWater Softener Installation / Operation Manual
Water Softener Installation / Operation Manual BrassMaster and BrassMaster Plus Technical Video Library: http://watercontrolinc.com/residential-technical-support/residential-technical-videos BrassMaster
More information565 HIM Softener, Iron & Manganese Reduction System
565 HIM Softener, Iron & Manganese Reduction System Owners Manual 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit)
More informationWS1 Softener Installation & Start-Up Guide
WS1 Softener Installation & Start-Up Guide Thank you for purchasing a Van Isle Conditioner. With proper installation and a little routine maintenance your system will be providing treated water for many
More informationInstallation Instructions and Owner s Manual. FS, FSM, & FES Series. Water Softening System
Installation Instructions and Owner s Manual FS, FSM, & FES Series Water Softening System MODEL NUMBERS: Time Clock Mechanical Metered FSL Series FSLM Series FS Series FSM Series High Efficiency High Efficiency
More information1 P a g e. G4 Counter Top OPERATION MANUAL
1 P a g e G4 Counter Top OPERATION MANUAL Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9
More informationFully Automatic Water Softeners
OWNERS GUIDE TO INSTALLATION AND OPERATION Fully Automatic Water Softeners SINGLE TANK CABINET MODELS TWO TANK MODELS Read the instructions carefully and learn the specific details regarding installation
More informationInstallation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener
Installation, Operation, and Maintenance Manual Waterlogix Metered Residential Water Softener Waterlogix WLS-075 Waterlogix WLS-075C Waterlogix WLS-100 Waterlogix WLS-100C Waterlogix WLS-150 Waterlogix
More informationInstallation and Operation Manual
Installation and Operation Manual NOTE: RISER / DISTRIBUTOR PIPE SHOULD BE CUT 1/2 BELOW THE TOP SURFACE OF THE TANK INSERT. MTS 95 System REVISION # 3 REVISION DATE SEPTEMBER 12, 2013 2 Table of Contents
More information~-ti-=t"- MODELS. !'..,.~-_ ~ _,, -:~.. l- l.. -l > _ {.- ~ t "',, j ~ t. t- -,l-~ -+ _ "'l.,.._
MODELS 85 95 93 }_""'_'""->""'"""''''''''~''''"'''''''''''''''~"''_~'''-"'''->'''~ "".,'"'.);,.."."..".,_...';'_.. k'~, ~,- ~ :. ;:,.,-""-..,...c"'''''''"'v''''''..- '''."..:...-, ''t''''''''-''' ~, >'''.,t-c.,.,r.
More informationNOT EVERYTHING IN LIFE IS COMPLICATED.
NOT EVERYTHING IN LIFE IS COMPLICATED. SCALEMASTER SOFTLINE 150 INSTALLATION & OPERATING PROCEDURES OWNERS MANUAL SCALEMASTER A Division of DAW Enterprises Ltd Emerald Way, Stone Business Park, Stone,
More informationInstallation Instructions and Owner s Manual. N, NMS, NES, & INT2 Series. Water Softening Systems
Installation Instructions and Owner s Manual N, NMS, NES, & INT2 Series Water Softening Systems MODEL NUMBERS: Time Clock Mechanical Metered NC Series NMCS Series N Series NMS Series High Efficiency High
More informationHigh Flow 7000 SXT Series Water Softeners
High Flow 7000 SXT Series Water Softeners Operating and Maintenance Manual Read all instructions carefully before operation. #54736 12/08 Performance and Specifications Model Capacity - Grains Flow Rates
More informationInstallation and Operation Manual
City Softener Model NSR 17CS How to install, operate and maintain your Ultra Demand Automatic Water Conditioner If you have any questions or concerns when installing, operating or maintaining your water
More informationModel LF-310 Air Operated
Microflush Half Gallon Toilets Model LF-310 Air Operated Installation/Service Manual P/N 24156 452 East Hill Road Fax: 707.459.6617 Willits, CA 95490 USA E-mail: info@microphor.com Phone: 707.459.5563
More information2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL
2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL www.excaliburwater.com Barrie, ON L4N 4Y8 Water Softener Introduction: Please read Excalibur Water Systems Water Softener manual
More informationInstallation and Operations Manual
Excalibur Water Systems 2.0 HIGH CAPACITY Mid Series SIMPLEX WATER SOFTENER Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water Softener
More informationKinetico 2060f OD Sulfur Guard Installation Instructions
SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.
More informationManual update 2016 MC37/MFC3600
Manual update 2016 MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You
More informationChanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000
Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000 Water Dove Systems will not be ready for full use for 48-72 hours after install. Please plan you installation accordingly. Product Spec
More information5900e Greensand Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900e Greensand Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More information