Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire
|
|
- Reginald Carter
- 6 years ago
- Views:
Transcription
1 Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire Suppression Systems; and Chapter 34-National Electric Code. 1
2 This chapter sets forth the requirements for the installation of gas piping and gas appliance installation and gas appliance venting systems. 2
3 The definition of Point of Delivery is added in order to determine the location in a gas piping system where the Fuel Gas code becomes effective. The Fuel Gas code regulates all portions of the fuel gas system downstream of the Point of Delivery. 3
4 An approved pan is required under fuel gas appliances that create condensation that could cause building damage in the event of leakage or a blockage in the condensate drainage system. 4
5 Gas-fired appliances may be installed at floor level within enclosed spaces in a garage so long as that enclosed space has access only from outside of the garage and all combustion air is taken directly from the outdoors. 5
6 Gas piping shall be installed so as to not strain the piping or connections at appliances. The piping must be properly aligned and adequately supported. 6
7 All gas piping must be bonded to an effective ground-fault current path; however CSST gas piping must only be bonded to the building s electrical service grounding electrode system. 7
8 Regulator vent piping may be PVC only when installed outdoors. All regulator vent piping is to be installed per the regulator manufacturer s installation instructions. 8
9 Gas piping downstream of the Point of Delivery may not pass through any townhouse unit other then the unit served by such piping. The definition of townhouse is important in the application of this section. 9
10 Gas piping is no longer permitted to penetrate the foundation wall of a building below ground. 10
11 When both ends of a protective conduit installed in a slab terminate inside the building, the code prohibits the ends from being sealed. 11
12 The open ends of a conduit protecting gas piping that passes under the slab from one point in a building to another point within the building must extend above the floor at least two inches and may not be sealed. 12
13 This section of code recognizes the hazards in clearing fuel gas from existing lines and establishes criteria for the safe release. 13
14 When a manifold gas piping distribution method is installed, a new provision permits the appliance shutoff valve to be located at the manifold so long as it is not greater than 50 feet from the appliance. 14
15 The Maximum length of all connectors may not exceed 6 feet. 15
16 A minimum clearance of 24 inches is permitted when one of the following conditions exist as shown on next slide: 16
17 Clearance requirements for household cooking appliances have been added to the fuel gas codes requiring a minimum clearance of 30 inches from the cooking top to the underside of combustible material or metal cabinets. Specific exceptions are permitted to reduce the clearance to 24 inches minimum. 17
18 This chapter refers the user to the current Ohio Plumbing Code (OPC) for the installation, testing and operation of plumbing systems, with very few modifications. 18
19 Modifications to the plumbing code delete the requirement for a shower liner test and eliminate the need for a trap seal primer valve for garage floor drains. 19
20 While residential sprinklers are not required by code, this chapter provides the installation requirements for fire sprinklers should an owner or builder choose to install. 20
21 If sprinklers are to be installed in all or part of a dwelling, garage or accessory building, the sprinkler system shall be installed per any of the four methods indicated. 21
22 Chapter 34 contains the electrical provisions for the dwellings, garages and any accessory structures. 22
23 This chapter incorporates the 2011 Edition of the National Electrical Code (NEC) NFPA 70 to regulate the installation testing and operation of electrical systems. The RCO contains some specific modifications to the 2011 NEC. 23
24 This electrical code is modified to permit a single receptacle in a garage specifically for a garage door opener to not have to be ground-fault circuitinterrupter protected. 24
25 Similar to the previous item, the basement is now permitted to have a single receptacle for the sump pump that does not have to be ground-fault circuitinterrupter protected IF there is a GFCI-protected duplex receptacle within 6 feet of the sump pump. A receptacle that is not GFCI protected is also permitted for an alarm system. 25
26 GFCI protection has been extended to all receptacles that are within 6 feet of the outside edge of any sinks. 26
27 Arc-fault protection for branch circuits has been extended to all habitable spaces, except kitchens, but including hallways, closets and similar spaces. And that protection must be from a combination-type arc-fault current interrupter for the entire branch circuit. 27
28 While GFCI protection has been extended to the garages and unfinished grade-level areas of unfinished accessory buildings used for storage or work areas, please note that Arc-Fault Circuit Interrupter protection has been extended only to habitable spaces and omits kitchens, bathrooms and toilet rooms, laundry rooms and garages. 28
29 A receptacle outlet is now required for each balcony, deck, or porch. 29
30 Receptacles are now required for foyers greater than 60sf. 30
31 Ground rods must be listed or meet a minimum diameter of 5/8. 31
32 Ceiling mounted fans require a box listed to support a ceiling suspended fixture. 32
33 All light switches shall contain a separate ground. 33
34 Electrical non-locking type receptacles in new dwelling construction must be installed with tamper-resistant receptacles. 34
35 GFCI protections for electrically heated floors has been added for kitchens. 35
36 36
RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS
RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS Key Questions for Residential Inspections 1. What wiring methods will be used, and are the wiring methods suitable for the conditions? 2. Will multiwire branch
More informationMechanical Systems Submittal Guide
5200 Dover Center Road 440-777-8000 North Olmsted, OH 44070 North-Olmsted.com Mechanical Systems Submittal Guide Residential Code of Ohio (RCO) n applicant is free to submit any mechanical systems description
More informationAPPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL
This Appendix (2000 IRC Appendix-L) is produced, copyrighted, and maintained by the National Fire Protection Association Association, all rights reserved. Use of this Appendix is pursuant to license with
More informationBuilding Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
More informationONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)
Cheboygan County Department of Building Safety 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 TX: (231) 627-8813 FX: (231) 627-8454 www.cheboygancounty.net Service Entrance ONE- AND TWO-FAMILY
More informationInstructor: L. Keith Lofland
One and Two Family Dwelling Electrical Systems 2014 NEC AFCIs, GFCIs, and Other Dwelling Unit Requirements Training Presentation by: International Association of Electrical Inspectors Instructor: L. Keith
More information2009 ELECTRICAL CODE REQUIREMENTS
2009 ELECTRICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Inspection Request Line (231) 533-3510 Electrical requirements
More informationBUILDER S PRE-INSPECTION CHECKLIST
Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general
More informationCONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA
American Electrical Institute 2014 PART 2 83 CONTINUING EDUCATION FOR OREGON ELECTRICIANS AMERICAN ELECTRICAL INSTITUTE PO Box 31131 Spokane, WA 99223 www.aeitraining.com 84 PART 3 American Electrical
More informationFAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?
NEW CASTLE COUNTY DEPARTMENT OF LAND USE FAQ (Frequently Asked Questions) What is required to convert my unfinished basement to finished space? 1. To convert an unfinished basement to finished space, at
More information2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS
City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY
More informationElectrical Tech Note 107
Electrical Tech Note 107 Biosystems & Agricultural Engineering Department Michigan State University Understanding the Construction Code Rules, Part 8 1 Based on the 2014 NEC and the 2015 MRC The State
More information2011 and 2014 National Electrical Code Changes Residential Only
2011 and 2014 National Electrical Code Changes Residential Only Sponsored By: and.net Instructor: Fritz Gunther, Chief Electrical Inspector 585-436-4460 www.nyeia.com NEW YORK ELECTRICAL INSPECTION AGENCY
More informationEl 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST
ONE TWO FAMILY HOUSING INSPECTINO CHECKLIST Owner Name Property address Date of Inspection Inspector AREA OF INSPECTION COMPLAINT COMMENTS 1 Fences 2 Dumpsters 3 Trash building materials junk cars branches
More informationCHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017
CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017 The City of Portsmouth adopts the State Building Code, which adopts by reference The National Electrical Code, 2017(NEC), as Chapter 15, Part IV, of the
More informationInspection Checklist Mechanical Rough in
Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and
More informationBUILDER S PRE-INSPECTION CHECKLIST
Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general
More informationSteve Ramsey Home Inspections
Steve Ramsey Home Inspections I. STRUCTURAL SYSTEMS X A. Foundations Type of Foundation(s): Slab Foundation There is evidence of some foundation movement. Excessive caulk around windows, mortar and brick
More informationSummary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016
Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition
More informationI. STRUCTURAL SYSTEMS
I. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Pier & Beam - Crawlspace Opinion: All exposed areas of the foundation were examined visually. Examination of the foundation was limited to photographs
More informationRental Housing Inspection Guide
BOONE FIRE DEPARTMENT Rental Housing Division 515-432-3446 www.boonegov.com/rental BUILDING DEPARTMENT Rental Housing Inspection Guide Boone Fire Department Welcome to the Rental Housing Inspection Guide
More informationHabitability Guidelines
Habitability Guidelines for Relocated Manufactured Homes dced.pa.gov/mh @PADCEDnews Purpose The purpose of these habitability guidelines is to provide a reasonable level of assurance that the relocated
More informationTown of Cicero Local Code Amendments
Town of Cicero Local Code Amendments 2009 International Residential Code Local Amendments: DELETE Table R302.1 (Exterior Walls), see Attachment A. DELETE Exception for Subsection R313.2 (One and Two-Family
More informationLevel I Chapter 1 Worksheet
Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the
More informationAnalysis of Changes for the 5 th Edition (2014) of the Florida Codes
Analysis of Changes for the 5 th Edition (2014) of the Florida Codes Changes to the Florida Building Code, Fuel-Gas This Analysis of Changes for the 5 th Edition (2014) of the Florida Codes is intended
More informationThe one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.
The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1. 1 This new alternative testing standard for safety glazing, can
More informationCode verification sign-off
Code verification sign-off Following is a list of the most common manufactured home code non-compliant items found in used or altered manufactured homes. These are only the most commonly found items and
More informationAn Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010
An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 Putnam County Planning & Development Services Building & Zoning Division Compliance Section PO Box 1486 Palatka, FL 32178 1486 Office
More informationCHAPTER 7 ALTERATIONS LEVEL
CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration
More informationIFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND
CHAPTER 1 SCOPE AND CHAPTER 1 SCOPE AND ADMINISTRATION ADMINISTRATION 301.1.2 LP-Gas installations. Whenever there is a conflict between this code and NFPA 54 and B+NFOA 58 as adopted by the Nevada LP-Gas
More informationTHE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department
THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO 44039 TELEPHONE: (440) 353-0822 FAX: (440) 353-0823 Building Department INSTRUCTIONS FOR DECKS REQUIREMENTS FOR PERMIT: Completed
More informationRental Registration & Safety Inspection Program: Inspection Checklist
A. Exterior: Structure, Shelter, and Maintenance Roof, chimney, foundation, stairs, and decks are reasonably free of decay (e.g., severe cracks, soft spots, loose pieces, deterioration, or other indications
More informationAxiom Property Inspections
Cover Page Axiom Property Inspections Property Inspection Report 868 Wally Avenue, Henderson NV, 89178 Inspection prepared for: John Doe Agent: David Lawson - Axiom Inspection Date: 8/12/2010 Time: 2:30
More informationTABLE OF CONTENTS. Part I Administrative... 1
Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103
More informationConversion to Vacation Home Permit Life Safety Survey
P.O. Box 1190, Fort Collins, Colorado 80522-1190, Planning (970) 498-7683 Building (970) 498-7700, Larimer.org Conversion to Vacation Home Permit Life Safety Survey All dwellings used as short-term rentals
More informationVENTING GAS APPLIANCES NFPA 54 CODE
VENTING GAS APPLIANCES NFPA 54 CODE Better Buildings: Better Business Robert Parkhurst March 3, 2017 Objectives Standardize terminology Examine gas piping size and safety Simplify design rules Selection
More informationFAIRA TRANSPARENCY REPORTS. November 21, 2016
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 7307 22 nd Ave NW, Seattle, WA
More information2009 International Residential Code Draft of New Fire Sprinkler Related Requirements
1. IRC Sections R313 and R314, insert two new sections as follows: R313 FIRE SPRINKLER SYSTEM FOR TOWNHOUSES R313.1 Required Installation. An automatic residential fire sprinkler system shall be installed
More informationShort-Term & Accessory Short-Term Rental Safety Certification
Short-Term & Accessory Short-Term Rental Safety Certification Permit Application Center (City Hall) 555 Liberty St. SE, Room 320 Salem, OR 97301 503-588-6213 (For office use only) License #: If you need
More informationX-593 SOLID FUEL HEATING QUESTIONNAIRE
X-593 SOLID FUEL HEATING QUESTIONNAIRE CLEAR PHOTOGRAPHS & QUESTIONNAIRE REQUIRED FOR EACH INSTALLATION (UNITS & VENTS) NAME ADDRESS PHONE NO POLICY NO BROKER INSPECTED BY DATE GENERAL INSTALLATION QUESTIONS
More information2012 International Fuel Gas Code Design, Installation and Inspection Principles
Overview 2012 International Fuel Gas Code Design, Installation and Inspection Principles Based on the 2012 International Fuel Gas Code Administration Definitions General regulations Gas piping installations
More informationTHE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department
7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO 44039 TELEPHONE: (440) 353-0822 FAX: (440) 353-0823 INSTRUCTIONS FOR SWIMMING POOLS REQUIREMENTS FOR PERMIT: Completed application form Plot plan showing lot
More informationInspector FX Field Forms
Inspector FX Field Forms PROPERTY / CLIENT Customer File # Customer Contact Address City, St, Zip Phone Fax Email Inspection location Send report to Phone Neightborhood Main entry faces East North South
More informationCode Compliance Report
Department of Safety & Inspection Ricardo X. Cervantes, Director CITY OF SAINT PAUL Christopher B. Coleman, Mayor 375 Jackson Street, Suite 220 Saint Paul, MN 55101-1806 Telephone: 651-266-8989 Facsimile:
More informationRPP Inspection Documents
RPP DOCUMENTS RPP Inspection Documents n CNIC Inspection Criteria for RPP n CNIC Inspection Checklist for RPP Contact Your Local Housing Service Center www.cnic.navy.mil/housingquickreference INSTALLATION:
More informationRental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN
Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN 55021 www.faribault.org (507) 333-0359 Property Address: Number of Units Building Type Name
More informationBuilding and Safety Division Civic Center Dr, Bellflower, CA, (562) x
Building and Safety Division 16600 Civic Center Dr, Bellflower, CA, 90706 (562) 804-1424 x 2006 www.bellflower.org RESIDENTIAL BATHROOM REMODELS Information Bulletin: BS -004 Effective: 01-01-2011 Revised:
More informationHome Inspection Report
Home Inspection Report Your New Address, Your Town, USA Inspection Date: Inspection Date Prepared For: New Homeowner Prepared By: Complete Home Inspectors P.O. Box 1104 Smiths Station, Alabama 36877 Phone:
More informationInspection Checklist Mechanical Final
Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and
More informationC O D E S & A M M E N D M E N T S
SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and
More information2012 International Mechanical Code Significant Changes. About the Significant Changes
Significant Changes to the International Mechanical Code and the International Fuel Gas Code With Louisiana Amendments Copyright Materials This presentation is protected by US and International Copyright
More informationInspection Report 123 My Street Midland, GA
Buying, Selling or Building Your Home Inspection Company ROFESSIONAL INSPECTION SERVICES, LLC P.O. Box 9774 Columbus, GA 31908 706-565-0333 1-866-298-4251 Inspection Report 123 My Street Midland, GA This
More informationInspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.
Page 1 of 22 Inspection Report Prepared For: Joe Smith Property Address: #2 Chicago, IL Inspectrum Inc. Julio Neira Inspectrum Inc Suite #227 3139 N Lincoln Ave. Chicago Il. 60657 Page 2 of 22 INVOICE
More informationSCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE
SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential
More informationLand Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2007
General: 1) (Q) May the gas be turned on temporarily to the gas piping system without the installation of the appliance? (A) NO! 2) (Q) Are traps required on all condensate drains from equipment? (A) Only
More informationInside Out Home Inspections
Cover Page Inside Out Home Inspections Property Inspection Report Inspection prepared for: John Doe & Jane Doe Date of Inspection: 5/10/2014 Inspector: Lucas Sargent PO Box 514, Tioga, PA 16946 Phone:
More informationResidential Building Department Resource Package Plan Examination Check List BBS Form 2-1 RCO and 5 March 2015
Residential Building Department Resource Package Plan Examinati Check List BBS Form 2-1 RCO 107.4 and 5 March 2015 EXAMPLE RESIDENTIAL PLAN REVIEW CHECKLIST Title Sheet or Applicati RCO 106.1.3 (1), 107.2
More informationCanadian Property Inspections
Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.
More informationVirginia Residential Code
2015 Virginia Residential Code 2015 Virginia Residential Code First Printing: September 2018 ISBN: 978-1-60983-846-1 COPYRIGHT 2018 by INTERNATIONAL CODE COUNCIL, INC. ALL RIGHTS RESERVED. This 2015 Virginia
More informationFAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 6137 Hazel Loop SE, #D, Auburn, WA 98092 Thank you for your interest in this Faira Certified
More informationWhat You Need to Know about Residential Sprinkler Design
What You Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com The Residential Sprinkler
More informationInspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc
Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by: Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include
More informationRead Only Document Not For Distribution
Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.
More informationPLUMBING REQUIREMENTS
PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all
More informationIMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016
IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS June 17th, 2016 RE: City Council Adopts 2014 National Electrical Code with Pool Alarm Requirements On April 25th, 2016 the
More informationInspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services
Inspection Report Mr. XXX Property Address: Sondrio Dr Las Vegas NV 89134 Cover Page Skye Canyon Home Inspection Services Clement Ijidakinro IOS.0002457-RES 8414 W. Farm Road, Suite180 #232 Las Vegas,
More informationNEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold
NEC {CODE CHANGES OVERVIEW OF 2014 Related to Electrical Wiring Devices { Cablofil Pass & Seymour Wiremold TABLE OF CONTENTS Page i NEC SECTION DESCRIPTION PAGE 210.8(A)(9) GFCI Protection of Receptacles
More information2015 MECHANICAL CODE REQUIREMENTS
2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per
More informationTABLE 1-E (2017) Effective July 1, 2017
TABLE 1-E (2017) Effective July 1, 2017 Oregon Amendments to the 2017edition of the National Fire Protection Association (NFPA) 70, National Electrical Code (NEC) for the 2017 Oregon Electrical Specialty
More informationInspection Checklist Residential Mechanical Rough In July 2016
Inspection Checklist Residential Mechanical Rough In July 2016 This Inspection Checklist reflects code requirements of the 2015 International Residential Code (IRC), the 2015 Uniform Plumbing Code (UPC),
More informationLand Use and Environmental Service Agency (Code Enforcement) NC Mechanical Code. Table of Contents
Table of Contents Chapter 1 Administration Chapter 2 Definitions Chapter 3 General Regulations Chapter 4 Ventilation. Chapter 5 Exhaust Systems Chapter 6 Duct Systems Chapter 7 Combustion Air Chapter 8
More informationExtra Mile Inspection, Inc.
Cover Page Property Inspection Report Inspection prepared for: Jerry and Lynne Richardson Real Estate Agent: Polly Richardson - BHKR Lake Forest Date of Inspection: 3/13/2017 Time: 12 pm Age of Home: built
More informationInspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)
Page 1 Doc #: Inspector: Date: Dwelling Address: Client Name: Client's Agent: Real Estate Company: Please refer to the General Home Inspection Contract. Thank you for using Minnesota and Western Wisconsin's
More informationSUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM
SUMMARY 1234 Main St.Severn 21144 Buyer Name 07/18/2018 9:00AM Henry Toman MD License 32391 1st American Home Inspection, LLC 443-685-4062 henrytoman61@gmail.com The summary is meant to organize the defects
More informationThe Home Inspector Alaska LLC Donna Ranson Certified Inspector Cell:
INSPECTION REPORT CLIENT INFORMATION TIME: 10:30 am Duane s Antique Market 349-7078 WEATHER: sunny,74 deg akauction@gci.net INSPECTOR PERSONS PRESENT Donna Ranson Owner OL# HINI37 ASHI# 207853 EXTERIOR
More informationWhat Builders Need to Know about Residential Sprinkler Design
What Builders Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com Agenda Brief history
More informationNATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY
A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -
More informationMaintence/Renewal Report
Maintence/Renewal Report Property Address: C4U Inspections Lloyd Kenzle CPBC # 47652 3518 Webber Rd. West Kelowna, BC V4T 1H9 866 765-4434 Table of Contents Cover Page... 1 Table of Contents...2 I SUMMARY...
More informationPipe Sizing Table. Hydraulic Load Served (fixture units)
MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3
More information101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)
City of York Qdot Engineering 101 S. George St 116 E Gas Ave York, PA 17405 York, PA 17405 (717) 849-2329 (717) 744-8315 INSPECTION CHECKLIST Residential Mechanical 2009 Codes This checklist is intended
More informationCHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R
CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES
More informationICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.
ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away
More informationWatson Home Inspection Services, LLC.
Cover Page Watson Home Inspection Services, LLC. Property Inspection Report 16466 Olalee Rd, Apple Valley Ca., 92307 Inspection prepared for: Jesse Owens & Zona Owens Agent: Ofir Andrews - Hamilton Landon
More informationThe Ultimate Home Inspection Checklist
The Ultimate Home Inspection Checklist This checklist is not meant to take place of a professional home inspection and does not contain every aspect of a home inspection. Use the checklist as a guide and
More informationThe Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM
The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM Property Address: Age of Quarters: Years Date of Inspection: INSPECTION TEAM: Names: Profession/Position (i.e. Board Member,
More informationTarrant County Community Development Division
Tarrant County Community Development Division MINIMUM ACCEPTABLE STANDARDS FOR REHABILITATION AND NEW CONSTRUCTION MANAGEMENT Tarrant County Community Development 1509-B South University Drive Suite 276
More information2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms
2014 Alberta Building Code Part 9 changes relating to Smoke and CO Alarms 9.32.3.9 Carbon Monoxide Alarms What has not changed: 4) & 6) In a residential occupancy containing a fuel burning appliance or
More informationVentilation for New Low-Rise Residential Buildings July 20, 2015
Ventilation for New Low-Rise Residential Buildings July 20, 2015 BSC Standard 01 2015 Building Science Corporation 3 Lan Drive, Suite 102 Westford, MA 01886 www.buildingscience.com Contents 1. PURPOSE...3
More informationResidential Wiring (2014 NEC) (Homestudy)
Residential Wiring (2014 NEC) (Homestudy) Oregon Electrical License This course will cover the requirements in the 2014 NEC for installing electrical systems in dwelling units. Code sections for residential
More information2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14
The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. PIPING Various Brass REVISED
More information2009 IRC. and Fuel gas Provisions
2009 IRC Q &A Plumbing, MechanICAl and Fuel gas Provisions TABLE OF CONTENTS PREFACE... vii ABOUT THE INTERNATIONAL CODE COUNCIL...viii PLUMBING PROVISIONS... 1 CHAPTER 25 PLUMBING ADMINISTRATION....3
More informationSTACKS AND STACK VENTS
CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing
More informationNEC Code Changes. Overview of 2011 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold
NEC Code Changes Overview of 2011 Related to Electrical Wiring Devices Cablofil Pass & Seymour Wiremold 104 P Street Belle Chasse, LA 70037 504-394-4132, fax 504-394-6922 www.pembaserv.com Legrand/Pass
More informationFAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98275 August 8 th, 2017 We have
More informationFACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev
This fact sheet provides an overview of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. These revisions are published
More informationCode Compliance Report
Department of Safety & Inspection Ricardo X. Cervantes, Director CITY OF SAINT PAUL Christopher B. Coleman, Mayor 375 Jackson Street, Suite 220 Saint Paul, MN 55101-1806 Telephone: 651-266-8989 Facsimile:
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More information2016 Plumbing Supplemental Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for
More informationFIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011
HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines
More informationCity of Rehoboth Beach
City of Rehoboth Beach Building & Licensing 229 Rehoboth Ave Rehoboth Beach, DE 19971 Office: (302) 227-6181 x222 Fax: (302) 227-4504 www.cityofrehoboth.com Residential Rental Safety Certification Pictorial
More information