INSTALLATION AND OPERATION MANUAL
|
|
- Richard Clark
- 5 years ago
- Views:
Transcription
1 INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 /
2 The company E. is outstanding in the field of central heating and air conditioning. For many years offers high quality products, using contemporary machinery and certified materials. Last years the company had made serious investments in establishments and equipment. The products include: Heating boiler units Steel Boiler for light oil and gas fuels Air-heating boiler Steel boiler for solid fuels The company maintains approved Quality Assurance System according to ISO 9001:2000. CONTENTS 1. Description 2. Technical Data 3. Installation Instructions 4. Operation Instructions 5. Faults 6. Control Panel 7. Declarations of Conformity NOTICE All values contained in this manual may change without notification. Page 2 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
3 Description Hot water boilers RADIALAND represent the most advanced technology for central heating boilers. The hot-water AR boiler series are steel made with pressurized combustion chamber and flame reverse. The flue gases follow a triple travel through the boiler. The first and second travel is inside the combustion chamber and the third travel through the flue gas tubes. Hot-water boiler AR series cover the need of heating power from kw ( kcal/h). Boilers with bigger nominal power are manufactured by order. The parts consist the boiler are shown in Figure Water chamber 2. Combustion chamber 3. Tubes (Flue pipes) 4. Tube plates 5. Boiler door 6. Smoke chamber 7. Flue gas output connection 8. Water output connection 9. Water input connection 10. Boiler insulation 11. Boiler base 12. Burner adjustment opening 13. Flame observation hole 14. Flue gas chamber cleaning opening 15. Boiler evacuation connection 16. Baffles (gas deceleration) 17. Expansion tank connection 18. Boiler covers Figure 1. Boiler section RADIALAND - BOILER's INSTALLATION MANUAL Page 3 of 14
4 Technical Specification No Characteristics AR 30 AR 40 AR 50 AR 60 AR 80 AR Output power - ΜΑΧ kw 34,32 46,50 55,80 62,6 87,20 116,20 Mcal/h 29,530 40,000 48,000 53,862 75, ,000 2 Output power range - ΜΙΝ kw 30,00 37,00 50,00 60,00 64,00 90,00 Mcal/h 25,800 31,850 43,000 51,650 55,100 77,450 3 Maximum input Power kw 38,09 51,58 61,73 69,16 96,14 127,69 Mcal/h 32,774 44,381 53,110 59,510 82, ,869 4 Fuel rate kg/h 3,22 4,36 5,21 5,84 8,12 10,78 5 Efficiency % 90,1 90,15 90,4 90,5 90, Temp control range C < 90 7 Max operating temperature C 90 8 Max operating pressure bar 3 9 Test pressure bar 4 10 Water capacity lt Boiler weight kg Draught mbar -0,25-0,25-0,27-0,27-0,28-0,30 13 Flue gas resistance and combustion chamber pressure mbar 0,5 0,5 0,6 0,7 0,8 0,9 14 Flue gas output temperature C Flue gas connection diameter mm Combustion chamber Type : cylindrical Length : mm Diameter : mm Fuel type light oil 18 Operational mode on-off - 1 stage 19 Electrical Power : W 250 Voltage : V / Hz 230 / Burner fixing dimensions mm Φ100 x 115x115 Φ125 x 115x115 Φ125 x 125x IP code number IP 20 Page 4 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
5 No Characteristics AR 120 AR 150 AR 180 AR 200 AR 250 AR Output power - ΜΑΧ kw 137,76 174,30 209,20 232,5 290,60 348,70 Mcal/h 118, , , , , ,000 2 Output power range - ΜΙΝ kw 122,00 140,00 180,10 215,00 245,00 302,20 Mcal/h 105, , , , , ,000 3 Maximum input Power kw 150,74 190,08 227,39 251,98 314,84 377,38 Mcal/h 129, , , , , ,707 4 Fuel rate kg/h 12,73 16,05 19,20 21,28 26,59 31,87 5 Efficiency % 91,4 91, ,27 92,3 92,4 6 Temp control range C < 90 7 Max operating temperature C 90 8 Max operating pressure bar Test pressure bar 4 5,5 10 Water capacity lt Boiler weight kg Draught mbar -0,30-0,35-0,40-0,40-0,45-0,50 13 Flue gas resistance and combustion chamber pressure mbar 1,25 1,75 2,25 3,25 3,8 4,2 14 Flue gas output temperature C Flue gas connection diameter mm Combustion chamber Type : cylindrical Length : mm Diameter : mm Fuel type light oil 18 Operational mode on-off - 1 stage 19 Electrical Power : W Voltage : V / Hz 230 / Burner fixing dimensions mm Φ140 x 125x125 by order 21 IP code number IP 20 RADIALAND - BOILER's INSTALLATION MANUAL Page 5 of 14
6 No Characteristics AR 350 AR 400 AR 500 AR 600 AR 800 AR Output power - ΜΑΧ kw 406,80 464,90 581,10 697,30 929, ,20 Mcal/h 350, , , , , ,000 2 Output power range - ΜΙΝ kw 371,90 430,00 499,80 616,00 755,40 987,90 Mcal/h 320, , , , , ,000 3 Maximum input Power kw 440,26 503,14 628,90 753, , ,43 Mcal/h 378, , , , , ,062 4 Fuel rate kg/h 37,18 42,49 53,11 63,66 84,89 106,1 5 Efficiency % 92,4 92,4 92,4 92,5 92,5 92,5 6 Temp control range C < 90 7 Max operating temperature C 90 8 Max operating pressure bar 4 9 Test pressure bar 5,5 10 Water capacity lt Boiler weight kg Draught mbar -0,52-0,55-0,58-0,60-0,70-0,70 13 Flue gas resistance and combustion chamber pressure mbar 4,2 5,0 5,6 6,0 7,1 7,1 14 Flue gas output temperature C Flue gas connection diameter mm Combustion chamber Type : cylindrical Length : mm Diameter : mm Fuel type light oil 18 Operational mode on-off - 1 stage 19 Electrical Power : W Voltage : V / Hz 230 / / Burner fixing dimensions mm by order 21 IP code number IP 20 Page 6 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
7 Installation Instructions In the following table the basic boiler dimensions are shown, so during the boiler installation all the required information are available (like water connections, chimney diameter required, boiler dimensions). The boiler installers should read this table in order to ensure that the required space is available at the boiler room. BOILER TYPE Water IN / OUT connection Expansion tank connection Evacuation connection Chimney diameter WIDTH HEIGHT LENGTH inch inch inch mm cm cm cm AR30 1¼" ¾" ½" AR40 1¼" ¾" ½" AR50 1½" ¾" ½" AR60 1½" ¾" ½" AR80 2" ¾" ½" AR100 2" ¾" ½" AR130 2" ¾" ½" AR150 2" ¾" ½" AR180 2½' ¾" ½" AR200 2½' 1" ½" AR250 3" 1" ½" AR300 3" 1" ½" AR350 3" 1¼" ¾" AR400 3" 1¼" ¾" AR500 4" 1¼" ¾" AR600 4" 1½" 1" AR800 4" 1½" 1" AR1000 4" 1½" 1" During the burner adjustment that fixed with the boiler, the maximum heat input (the fuel consumption rate) and the boiler efficiency (%) in full load should be considered (see boiler technical specification). RADIALAND - BOILER's INSTALLATION MANUAL Page 7 of 14
8 During the boiler installation and connections, attention should be given to the following points: The boiler should be installed in horizontal position in an appropriate place (boiler-room) and with appropriate ventilation. The installation should be carried out by approved qualified technicians. Around the installed boiler there should be enough space for repair and maintenance. The boiler installation should follow the European legislation and in agreement to the applying heating study. The installation should include, except the burner and the suitable circulating pump, automating filling valve and safety valve regulated in pressure smaller than the maximum permissible boiler operating pressure. The installation should include a thermostat to control the burner operation (ON/OFF) with maximum adjustment smaller than the maximum permissible operation temperature and a thermostat to control the water circulating pump. All electrical equipment should be connected with a separate controlled electrical circuit. Before first boiler operation, please check the following points: the water level at the heating circuit, the oil at the oil tank and the proper burner connection, the proper adjustment of burner and circulating pump thermostats, the proper connection and the power supply of the electrical circuit and the proper fixing of the baffles in the flue gas tubes. Special care should be taken to avoid liquids due to flue gas humidity to run inside boiler (corrosion danger). Page 8 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
9 Operation Instructions For boiler protection and its effective operation, appropriate maintenance should be carried out by professionally qualified technicians. This maintenance should include operational check and cleaning for both boiler body and burner. The maintenance is very important because ensures the long life of the boiler and the high efficiency rate (savings in fuel consumption). The regulation of the boiler s operational parameters and especially the burner fuel consumption should always be in the effective area of the power range. Very important for boiler efficiency is the flue gas temperature. In any case the baffles should not be taken off the flue gas tubes, because they directly affect the flue gas temperature and boiler efficiency. Inspections (every month) For leakages, electrical connections, oil filter, etc. At the beginning of the operation period (September) Boiler cleaning (combustion chamber, tubes, flue gas baffles, smoke chamber), Burner cleaning, Oil filter cleaning, Burner operation adjustment (choice of right operation parameters like oil pump pressure and air adjustment), Safety valve, ventilation, thermostats and insulation check, Flue gas concentration and temperature measurement. RADIALAND - BOILER's INSTALLATION MANUAL Page 9 of 14
10 Faults During boiler operation, faults may occur that effect its proper operation (either directly block of operation or indirectly). Examples of faults are given below. Fault Actions to do Burner block Check the oil level at the tank Clean the flame detection sensor of the burner (read the burner instructions manual) Press the burner RESET button for restart (max 4 times) Boiler overheating Check the air trapping through the heating circuit. Press the top valve to release the air trapped. Check if the circulating pump operates normally. In case that it does not operate, check the activation circuit (sensors, power) or read manufacturer instructions Press the overheating sensor RESET button in control panel. High temperature in chimney or in flue-gas chimney output Stop the boiler operation. Check if baffles installed inside the flue gas tubes. Replace the baffles that are damaged. Measure the flue gas temperature in chimney with appropriate thermometer. The temperature should be relevant with the value given in the boiler specifications. In any case the temperature should not exceed 250 C. Flue-gas leakage Check the cause of flue gas leakage (boiler door, flue gas chamber and chimney). In case that the leakage cannot be restricted, replace the damaged materials (glass made cord, silicon, etc). Take measures to avoid carbon oxide concentration (ensure appropriate ventilation). ATTENTION: In case that after yours actions appropriate for the existing fault, the operation of the boiler is not normal, please ask for help from approved qualified technicians. Page 10 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
11 Control Panel The control panel includes all the necessary equipment for the proper control of the boiler operation. The control panel is fixed at the top of the boiler. It has a metallic shell, which includes all the required equipment that are necessary for proper boiler operation. The following figure shows the control panel and its equipment. 1. Power Switch ON / OFF with led 2. Boiler water thermometer 3. Burner thermostat 4. Circulation pump thermostat 5. Overheating fuse Figure 2. Boiler control panel RADIALAND - BOILER's INSTALLATION MANUAL Page 11 of 14
12 Control Panel connections During boiler installation the control panel connection terminals should be connected as follows: to electric power supply 230V / 50 Hz to air thermostat to burner to circulation pump L N GND T 1 T 2 N L N GND L N GND Special attention should be given in ground connection. No one part should be connected in power without prior connection to ground (GND). In other case there is serious danger for electric shock. Page 12 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
13 Declaration of Conformity This is to declare and assure that hot-water boiler RADIALAND AR series (pressurized steel oil-fired boilers with flame reverse) of are made according to the type described in EC Type Examination certificate and satisfies the relevant requirements of 92/42/EC directive relevant with "efficiency requirements for new hot water boilers fired with liquid or gaseous fuels". The results of testing conducted are: Characteristic Data AR 30 AR 60 AR 120 AR 200 Nominal Output Power kw 34,32 62,61 137,76 232,50 kcal/h Efficiency in full load % 90,10 90,515 91,40 92,27 Efficiency in part load (30%) % 88,80 89,26 91,72 90,13 Efficiency Marking For Manufacturer Elias Kostopoulos 15/02/2008 Manufacturer Data ELIAS RADIALAND SA 40 ο km Thessaloniki Athens Aiginio GR Tel , Fax RADIALAND - BOILER's INSTALLATION MANUAL Page 13 of 14
14 Page 14 of 14 RADIALAND - BOILER's INSTALLATION MANUAL
Technical information. Remeha P200. Pressurized boiler. Heat output: kw
Technical information Remeha P200 R e m e h a P 2 0 0 Pressurized boiler Heat output: 59-256 kw Remeha P 200 CONTENTS Preface 3 1. Description of the unit 4 1.1 General 4 1.2 Burners 4 2. Construction
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationR e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw
Technical Information Remeha P 300 R e m e h a P 3 0 0 Pressurized boiler Heat output: 278-709 kw Remeha P 300 CONTENTS Preface 3 1 Description of the unit 3 1.1 General 3 1.2 Burners 3 2 Construction
More informationJUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS
JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods
More informationCalder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model
Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder
More informationWHE 2.24 / WHE 2.24 FF
EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationCalder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model
Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency
More informationRoom sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23
Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,
More information1. GENERAL SAFETY RULES
ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance
More informationOPERATING INSTRUCTIONS with safety features
Solid fuel boiler TKK3 with wood pellet burner TERMEC 70-90 KW OPERATING INSTRUCTIONS with safety features Prhova ka bb 22310 imanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs
More informationACCUMULATION OF EUROPEAN CLASS
ACCUMULATION OF EUROPEAN CLASS Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the
More informationRODI DUAL RODI DUAL HR
IST 03 C 320-04 RODI DUAL RODI DUAL HR PRESSURISED STEEL BOILER EN INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you selecting our company and choosing to purchase our products. We invite you to
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More informationen Direct oil-fired space heaters HD... Operator's manual
0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...
More informationTechnical information. Remeha P 500. Pressurized boiler. Heat output: kw
Technical information Remeha P 500 R e m e h a P 5 0 0 Pressurized boiler Heat output: 635-1900 kw Remeha P 500 TABLE OF CONTENT Preface 3 1 Description of the unit 3 1.1 General 3 1.2 Burners 3 2 Construction
More informationRemeha. Fuel oil/gas boilers P 520. Installation and Service Manual A
Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It
More informationGAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw
GAS FIRED ATMOSPHERIC ELECTRONIC VERSION 51-102 kw GENERAL DESCRIPTION 900 D a3 1000 762 672 E 222 The PEGASUS F2 range of atmospheric natural gas-fired boilers are constructed of cast iron finned sections
More informationST 40 Oil Burner. Installation & Maintenance Manual
ST 40 Oil Burner Installation & Maintenance Manual 178 093 13 Thank you for choosing a Nu-way burner. As you would expect from a Company who has a pedigree of more than 75 years in the heating industry,
More informationOperating instructions
Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN Contents 1 For your safety..............................................
More informationDOMESTIC HOT WATER Follow operational sequence
DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded
More informationWALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C
ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on
More information1. The structure and its description
Thank you for using our KYUNG-DONG NAVIEN. To use this boiler in the proper way, be sure to read this manual fully before using it, and keep this manual with the warranty of the quality in a safe place.
More informationPCH/new Series. High performance, total flexibility
PCH/new Series High performance, total flexibility PCH/new Installation in Air Handling Unit Very Low Emissions NOx lower than 30 ppm : Class 5 Capacity Range 14 models from 5 kw to 400kW Automatic Control
More informationBiomass. Biomass solid fuel boiler range
Biomass Biomass solid fuel boiler range Biomass Fuelling positive change For more than150 years, Baxi has been at the forefront of heating technology Baxi leads the way with new and pioneering heating
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationHoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.
Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to bar. Heatpack boilers to 2900kW. Whether your application is for single, multiple or space saving heatpack boilers, Hoval always
More informationCAST IRON ATMOSPHERIC BOILERS
CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron
More informationINSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS G 2000-S 25-35 - 45-55 60-70 - 100 (V13) 1 Index WARNINGS GAS FLOW RATE DIMSIONS SETTINGS PARAMETERS SERVICING THE URNER 3 8 13 OPERATING DESCRIPTION
More information2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION
FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its diesel-burning boilers are produced in accordance with the requirements of article 3 paragraph 3 of Directive PED 97/23/EEC
More informationC Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat
C 146-02 made in Italy Elba Dual Cast-iron, floor-standing boiler High quality Italian product Life-enhancing heat GB Cast-iron, floor-standing boiler Elba Dual RELIABILITY SAFETY QUALITY EASY TO OPERATE
More informationWaste/Multi Oil Boilers from Flexiheat
Waste/Multi Oil Boilers from Flexiheat At a time of rising fuel costs, the Flexiheat FMOB universal/waste oil boiler range, which can burn nearly all vegetable, animal, conventional and waste oil, will
More informationSolid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance
Solid fuel hot water boiler TKH 250-400 KW INSTRUCTIONS MANUAL for usage and maintenance Prhovacka bb 22310 Simanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs April
More informationRIELLO 40 GS/M SERIES
The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.
More informationCast Iron Boilers. G Series ( kW)
Cast Iron Boilers G Series (320-1017kW) Mikrotherm G Series Cast Iron Boilers The Mikrotherm G Series of cast iron sectional boilers offer all the advantages of cast iron durability and longevity coupled
More informationVIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw
VIESMANN VITOLADENS 00-T Oil Unit condensing boiler 5.4 to 5.7 kw Datasheet Part no. and prices: see pricelist VITOLADENS 00-T Type VWB Ultra-low temperature oil boiler with condensing heat exchanger With
More informationClyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw
atural gas Class D oil Dual Fuel 350 kw to 500 kw Clyde CK40 Cast Iron Boiler Contents Page General information Dimensions 3 Technical data 3 Installation requirements 4 & 5 Boiler control panel 6 Wiring
More informationPCH Heating Condensing Module for Air Handling and Roof Top Units
40 Years Caring for Environment PCH Heating Condensing Module for Air Handling and Roof Top Units Efficiency as high as 105% Saving Up to 50% on Consumptions Environmentally friendly Efficiency as high
More informationOil burners Brûleurs fioul Stookoliebranders
Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement
More informationParts Available from
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
More informationOperating manual. Pellet boiler. Orlan Pellet ISO 9001
Operating manual Pellet boiler Orlan Pellet ISO 9001 Contens 1. Boiler s use...................................................................... 3 2. Boiler s way of working...........................................................
More informationEUROFLAT SERIES TYPES C... S... M...
EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas
More informationSo old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.
ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided
More informationINSTRUCTIONS FOR INSTALLATION, SETTING AND USE
BUILT-IN FIREPLACE INSTRUCTIONS FOR INSTALLATION, SETTING AND USE 1. BUILT-IN FIREPLACE SPECIFICATION - WIDE 730 mm - DEPTH 426 mm - HEIGHT 543 mm - NOMINAL POWER 11 KW - CHIMNEY POT DIAMETER Ø 180 mm
More informationVETO CLEANER 500 FLUE GAS CLEANER
As of serial number 3100 0001 VETO CLEANER 500 FLUE GAS CLEANER USER MANUAL SPARE PARTS LIST Manufacturer: ALA TALKKARI Veljekset Ala-Talkkari Oy FI-62130 HELLANMAA TEL. +358 6 433 6333 FAX +358 6 437
More informationKKKKKKKCOOKER HOOD INSTRUCTION MANUAL
KKKKKKKCOOKER HOOD INSTRUCTION MANUAL Read this manual carefully before operation Pictures in this manual are for reference only, the product in kind prevail. E60MEW2M19 Contents 01 02 03 04 05 06 07 08
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More informationFEATURES AND BENEFITS. Up to 109.8% part load efficiency
IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single
More informationH E AT I N G S Y S T E M S ECS STEEL BODY CENTRAL HEATING HOT WATER BOILER
H E AT I N G S Y S T E M S ECS STEEL BODY CENTRAL HEATING HOT WATER BOILER ECS 70 / 85 / 100 / 150 / 200 / 250 / 300 / 350 / 400 500 / 600 / 700 / 800 / 900 / 1000 TECHNICAL SPECIFICATIONS MODELS Unit
More informationCapri B Cast iron combination oil-fired boiler with water tank
C 151-01 Cast iron combination oil-fired boiler with water tank Life-enhancing heat GB Cast iron combination oil-fired boiler with water tank RELIABILITY SAFETY EASY OPERATION EASE OF MAINTENANCE Life-enhancing
More informationRapid. Suspended Warm Air Heater. Caring for the environment!
Rapid Suspended Warm Air Heater Caring for the environment! RAPID The QUICK and ECOLOGICAL Suspended Heater Our RAPID heaters were conceived and designed for the heating of industrial and commercial buildings.
More informationINSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO
INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply
More informationHoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar
Hoval SR-plus heating boilers Outputs from 30 to 4000kW Working pressures to 8 bar ...built in the UK where high quality and reliability have been a way of life for generations. Hoval SR-plus Simplicity
More informationIMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS
THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.
More informationSuperior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw
Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency
More informationUSER MANUAL 9kW LILLY PELLET STOVE
USER MANUAL 9kW LILLY PELLET STOVE Table of Contents.Overview of Stove Parts... 2.Technical Characteristics... 3 3.Important Information... 4 4.Pellet Specification...5 5.Technology... 6 6.Installation...
More informationVIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw
VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw Datasheet Part no. and prices: see pricelist VITOLADENS 300-C Type BC3 Oil condensing boiler, with two- Compact blue flame burner (12.9 to
More informationFonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11
Fonte Lx Instantaneus Gas Water Heaters, conventional flue, low NOx NEW Residential Heating XL M compliant Fonte Lx 14 Fonte Lx 11 FONTE Lx / Gas Water Heaters, conventional flue, low NOx THE RANGE FONTE
More informationCAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL
BRILEY CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER 60 140 kw 0604.2 Beeston Briley cast-iron premix gas-fired boiler 60-140kW Contents 1 Boiler specifications Page 3 2 Appliance general dimensions
More informationTermEfekt USER S MANUAL AIR HEATER. Model PGA 14
Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification
More informationBIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS
BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS W W W. A T T A C K. S K MODEL STRUC TURE OF THE AT TACK BOILERS THE NEW LINE OF ATTACK BOILERS FOR WOOD AND PELLETS 3000 000 6000 4 ATTACK FD PELLET yattack
More informationPrextherm Rsw High efficiency steel pressurised boilers
Prextherm Rsw High efficiency steel pressurised boilers > PREXTHERM RSW TOP RELIABILITY AND PERFORMANCES Prextherm RSW range consists in pressurised boilers with reversal flame technology. The historical
More informationProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.
1 MHG Heating Ltd ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR Telephone 08456 448802 Fax 08456 448803
More informationMerloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /
GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT
More informationBG2000S PRE-MIX GAS BURNER
BG000S PRE-MIX GAS BURNER INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 77 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com
More informationC Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat
C 083-03 Bali R Cast-iron boilers with atmospheric gas-fired burner Life-enhancing heat GB Cast-iron boilers with atmospheric gas-fired burner Bali R Easy installation Silent operation Long life Wide range
More informationTHW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler
Industrial Hot Water Boiler for Oil or Gasfiring Description Industrial Hot Water Boiler The Hoval high output hot water boilers are made of high quality steel and are distinguished by their solid, robust
More informationPZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL
BIOTECH THE FUTURE OF HEATING PZ 35 RL Heating with renewable energies is the future and you will not only contribute to the environment, you also will reduce massively your annual energy cost. The Biotech
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationCONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h
FORCED CIRCULATION Design pressure 11,76 bar Steam production from 45 to 4.000 Kg/h /V Design pressure 11,76 bar Steam production from 45 to 2.000 Kg/h INDUSTRIAL BOILER ITALY S.R.L. Offices and Production
More informationMax-3 Steel Shell Boiler
Max-3 Steel Shell Boiler Responsibility for energy and environment Output range 500 to 3000 kw 1 Why choose Max-3? The Hoval Max-3 boiler delivers market-leading efficiency and cost effective heating performance.
More informationDOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM
DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM S Y S T E M S THE SOURCE OF SUPERIOR SYSTEMS The new Sirrus Radiant wall hung boiler from Sirrus Systems offers good looks, comprehensive safety features and
More informationVIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.
VIESMANN VITOROND 100 Cast iron low temperature oil and gas fired boiler 40 to 100 kw Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 1 VITOROND 100 Type VR2B Cast iron
More informationHamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements
Exceeds Minimum Requirements Hamworthy Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters 18.9 kw to 20.1 kw, Natural Gas or LPG Continuous outputs 369
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use
More informationIDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80
IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...
More informationINSTALLATION AND MANINTENANCE INSTRUCTIONS
INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional
More informationUSER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book
USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationCapri R CH only, oil-fired, cast iron boiler
C 153-01 CH only, oil-fired, cast iron boiler Life-enhancing heat GB CH only, oil-fired, cast iron boiler RELIABILITY SAFETY EASY TO OPERATE EASE OF MAINTENANCE Life-enhancing heat CAPRI R range includes
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to
More informationWood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4
Wood gasification process... Wood as a fuel... Boiler construction - its elements...4 Boiler construction - materials...4 EKO advantages...4 Boiler construction - schematics... Boiler dimensions... Boiler
More informationHHIC consumer guide to gas boiler servicing
HHIC consumer guide to gas boiler servicing Gas Boiler Servicing Keep your home heating system in good working order. As a consumer, it is reasonable to assume that when procuring a service of your gas
More informationInstallation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)
Installation & Operating Manual ZM-130 16 32kW Universal Oil Heater OVERVIEW Dfdfdfdsfd Dfdfffdfdf Dfdfdf 4 1. Overheat thermostat 2. Combustion chamber lid 3. Oil feed line 4. Activation thermostat 5.
More informationFLUIDIZED BED BOILERS
FLUIDIZED BED BOILERS Proven technology for burning fuels on solid grate with a fountain fluidized layer; The possibility of burning a wide variety of solid fuels - with large heated value range coal,
More informationSince 1983 Nuova COTERM has developed a wide range of water heaters.
Since 1983 Nuova COTERM has developed a wide range of water heaters. Thank to careful attention to market demands and continuous research towards new solutions, Nuova COTERM is able to offer clients the
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A
178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle
More informationSavile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h
Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame
More informationAquaflam Wood boiler stoves and fireplace inserts
www.hsflamingo.com Aquaflam Wood boiler stoves and fireplace inserts AQUAFLAM wood boiler stoves and fireplace inserts from the HS Flamingo workshop have many above-standard features. These innovative
More informationUSER GUIDE VOGUE MAX SYSTEM
USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationOperating Instructions
Operating Instructions P4 Pellet 8-60 Read and follow the operating instructions and safety information. Subject to technical change. July 2009 Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline
More informationT UNI 7000 F. Operating instructions For the user (2006/05) AU/GB
6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols
More informationAIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube
LABORATORY MANUAL ON STUDY OF FIRE TUBE AND WATER TUBE BOILERS Prepared By Prof. (Dr.) M. K. Roul Professor and Principal, Gandhi Institute for Technological Advancement (GITA), Bhubaneswar 752054 June
More informationVIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw
VISMANN VITOLADNS 00-C Oil condensing boilers 12.9 to 28.9 kw Datasheet Part no. and prices: see pricelist VITOLADNS 00-C Type BC Oil condensing boiler With two-stage Compact blue flame burner (12.9 to
More informationSPECIFICATIONS - NIKE
Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks
More informationTECHNICAL MANUAL CODEX. THREE PASS CONDENSING BOILER WITH LOW NOx
TECHNICAL MANUAL CODEX THREE PASS CONDENSING BOILER WITH LOW NOx 1 GENERAL...4 2 GENERAL WARNINGS...5 3 HANDLING AND LIFTING...6 4 TECHNICAL DATA...7 4.1 DIMENSIONS AND FITTINGS...8 5 INSTALLATION...9
More informationOperating instructions
6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or
More informationWood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance
Wood logs boiler with a gasication eect IGNIS 20-40 KW INSTRUCTIONS MANUAL for usage and maintenance Prhovacka bb 22310 Simanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs
More informationGasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1
Gasification boiler PYROLYT INSTRUCTION MANUAL ver. 1.1 THERMOSTAHL would like to thank and congratulate you on your purchasing this boiler device and ensure that you have made a good choice. PYROLYT boiler
More information