1 JACKSON GAS WATER BOILER OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: Gas Water Boiler - 1

2 Model No. Product Description Rev. Date Jackson Water Boiler JG220R3 Expansion Boiler 1 11/05/00 Manual Part No: Gas Water Boiler - 2

3 INDEX Page Cover Sheet: 1 Revision Sheet: 2 Index: 3 Introduction: 4-5 Specification 6 7 Specification 6 Overall Dimensions 7 Installation Instructions: 8 10 Unpacking 8 Preliminary Cleaning 8 Location 8 Data Plate 8 Gas Supply 9 Water Supply 9 Overflow Connection 10 Operational Check 10 Precautions 10 User Instructions: Important Note 11 Operation 12 Service 13 Daily Cleaning 13 Servicing Instructions: Index 14 Technical Description 15 Fault Finding Chart Instructions Spare Parts List: Accessories: 31 Warranty Cover Sheet: 32 Manual Part No: Gas Water Boiler - 3

4 INTRODUCTION This manual contains all the required information to ensure that your new appliance is installed and serviced correctly and that you have all the information necessary to identify and order spare parts. It also contains comprehensive instructions for the user and for cleaning the appliance. To maintain peak performance, it is recommended that the appliance be regularly serviced and that when ordering spare parts, reference is made to the appropriate list quoting the Part Number and Description contained therein. THE FITTING OF A NON STANDARD PART MAY VOID ANY GUARANTEE. All work carried out on this appliance during installation or servicing must be performed by a competent person and the connection of the appliance to the gas supply MUST be carried out by qualified personnel in accordance, where applicable, with the relevant regulations. The siting of the appliance and the connection to the gas supply must comply with the latest GAS SAFETY (INSTALLATION & USE) REGULATIONS 2000: the requirements of the FIRE PRECAUTIONS ACT 1971; the HEALTH & SAFETY AT WORK, ETC ACT 1974, the BUILDING STANDARDS (SCOTLAND) CONSOLIDATION REGULATIONS Detailed recommendations are contained in British Standards BS5440 Part 1:2000, BS5440: Part 2:2000, BS5588: Part 0:1996, BS5588: Part 11:1997 & BS6173: An easily accessible stopcock must be fitted in the gas supply adjacent to the appliance for use in emergency. The details of the gas supply will be found on the Data Plate, which is located at the bottom front corner on the right hand side Improvements The policy of Viscount Catering Ltd is such that, each product is subject to continual development and may, therefore, be subsequently improved. The company reserves the right to alter the design of any appliance without prior notification and without the responsibility to update any delivered or in-service appliance and furthermore, without incurring the responsibility for altering these instructions. In such circumstances, it may be found that the appliance detailed herein differs in certain respects from the one supplied. IT IS IMPORTANT, THEREFORE, TO QUOTE THE SERIAL No. AND THE APPLIANCE MODEL No. IN ALL COMMUNICATIONS WITH THE COMPANY. Manual Part No: Gas Water Boiler - 4

5 Introduction (cont.) Important Before installing any item please refer to the installation instructions. We recommend that all servicing other than routine cleaning be carried out by out authorised service agents and will accept no responsibility for work carried out by other persons. For satisfactory operation, parts of catering equipment become hot. Suitable precautions must be taken to avoid accidental burns therefore the appliance should be positioned to minimise the possibility of accidental touching. It is the supervisors responsibility to warn users to wear suitable protection and to follow correct operation and cleaning procedures. For the details of your nearest Service Agent for all warranty repair work, you should contact:- The Service Manager, Viscount Catering Limited Provincial Park Nether Lane Ecclesfield Sheffield S35 9ZX Tel: +44 (0) Fax: +44 (0) Spares can be obtained via the Spare Parts Department at the above address. IT IS IMPORTANT, TO QUOTE THE SERIAL No. AND THE APPLIANCE MODEL No. IN ALL COMMUNUCATIONS WITH THE COMPANY Manual Part No: Gas Water Boiler - 5

6 SPECIFICATION The G220R3 Gas Heated Expansion Boiler will deliver 220 pints of boiling water per hour. Both Natural Gas and LG gas versions are available. The mains water supply should be connected to the ½ BSP mains inlet connection at the top right of the unit. Gas Pressure: Natural Gas 9.6 mbar (3.8 w.g.) Propane Gas 37mbar (14 w.g.) Heat Input (Nett) Model kw/hr Btu/hr Bypass kw/hr Output/hr G220R3-NG 1.572m 3 /hr , Pints 124 Litres G220R3-LP 1.043kg/hr , Pints 124 Litres Burner Injectors Natural Gas Propane Gas Main 1.50 mm 0.82 mm Bypass 0.82 mm 0.55 mm Weight Empty kg (54.6 lbs) Full kg (69.5 lbs) Water Connection and Level Control The float valve controlling the water level in the cistern and boiler is designed to operate at all pressures up to 200 p.s.i. but it is advisable not to use pressure below 10 p.s.i. for the safe operation of the boiler. Manual Part No: Gas Water Boiler - 6

7 Specification (cont.) Manual Part No: Gas Water Boiler - 7

8 INSTALLATION Important Your attention is drawn to the latest GAS SAFETY (INSTALLATION & USE) REGULATIONS This appliance MUST be installed by a competent person in accordance with these and any other relevant regulations. Users, too, should be aware of the regulations governing the use of gas appliances, particularly with respect to the need for regular servicing. 1) Unpacking Remove all wrapping and packing materials from the exterior and interior of the unit. 2) Preliminary Cleaning All the Stainless Steel exterior surfaces are covered with a plastic protective film, which MUST be removed before operating the unit. Peel the film off manually, and then clean the exposed Stainless Steel with a cloth moistened with white spirit to remove the tacky adhesive remaining. CAUTION: WHITE SPIRIT IS INFLAMMABLE 3) Location The boiler must be fixed to a level surface (see drawing for hole positions). Where possible a drip tray should be sited in front of the boiler and the waste water PIPED away using the waste union in the tray. If a drip tray is not fitted, the overflow should still be PIPED away to avoid any damage if the boiler overfills. Important: Any overhanging shelf, fitment or ceiling should be at least 450mm (18 ) above the flue outlet and must be non-combustible or protected from heat by suitable cladding. Adjacent surfaces should be fireproof and resistant to discoloration. The boiler should be stood on a surface made of non-combustible material e.g. metal and a minimum clearance of 150mm (6 ) should be left between the adjacent wall and either side of the appliance for service access. The boiler is unsuitable for direct connection to an external flue, but it should be installed in a SUFFICIENTLY WELL VENTILATED ROOM to enable the removal of steam. The flue outlet must be free from obstruction so that the boiler will work correctly. 4) Data Plate This is located at the bottom front corner on the right hand side. Check that the information stamped on the data plate matches the gas supply. Manual Part No: Gas Water Boiler - 8

9 Installation (cont.) 5) Gas Supply The gas inlet to the appliance is 15mm and the supply pipe should not be less than this. ENSURE THAT ALL SUPPLY PIPING IS CLEAR OF RUST, DUST AND SWARF BEFORE CONNECTING UP. Use jointing material sparingly and avoid coating the first two threads of any connecting pipe. Gas Pressure Adjustment a) Adjust the governor, if necessary, to give correct burner-operating pressure. The governor is included in the gas control train at the rear of the boiler. b) The pressure test nipple is on the down tube between the relay valve and the burner. The pressure should be as follows: - Natural Gas 9.6 mbar (3.8 w.g.) Propane Gas 37 mbar (14.0 w.g.) c) Remove the cover nut on the governor. i) To increase pressure, screw the adjuster inwards (clockwise). ii) To decrease pressure, screw the adjuster outwards (anti-clockwise). d) Replace the cover nut and re-tighten. 6) Water Supply The water supply connection is ½ BSP male. THE BOILER MUST BE CONNECTED TO RIGIDLY SUPPORTED METAL PIPEWORK TO ENSURE STABILITY. If copper piping is used, it must be at least 15mm diameter. A union and stopcock should be fitted in such a manner that unauthorised persons will not operate it and as close to the boiler as possible for servicing purposes. IT MUST NEVER BE TURNED OFF WHEN THE BOILER IS IN USE. However, if the supply is accidentally turned off, the boiler has a safety cut-out, which will switch off the gas to the burners. Should the water supply be re-connected, the gas will remain off until manually re-lit All boilers are supplied fitted with a float valve suitable for water pressures from p.s.i. To convert to lower pressures, p.s.i, exchange the plastic screw provided for the one in the float inlet orifice (use a pair of long nose pliers to extract the high pressure screw). THIS APPLIANCE IS NOT RECOMMENDED FOR USE WITH WATER PRESSURES BELOW 10 p.s.i. Do not use white or red lead for making joints on water fittings. Before connecting the cold water supply pipe, flush out to ensure removal of all jointing materials and foreign matter. Manual Part No: Gas Water Boiler - 9

10 Installation (cont.) 7) Overflow Connection (3/4 Internal diameter) Overflow should be connected to a warning pipe where discharge of water can readily be seen without it endangering property or personnel. 8) Operational Check a) Ensure that the water supply is connected and turned on to the boiler. b) Check that the cistern is full to the level marked inside. c) Light the boiler in accordance with the lighting instructions fitted to the front of the boiler. d) Check output - approximately 3 1 /2 pints per minute. e) Draw boiling water from the appliance and check that the gas is cut off approximately 30 seconds after the water supply is turned off. If the flame is not extinguished, check for faults as outlined in pages16-18 of the Service Instructions. 9) Precautions Ensure that the exterior panels are replaced correctly after commissioning. ANY UNAUTHORISED MODIFICATION MAY IMPAIR THE SAFETY OF THE APPLIANCE AND WILL INVALIDATE THE GUARANTEE. Manual Part No: Gas Water Boiler - 10

11 USERS INSTRUCTIONS Important The attention of the user is drawn to the requirements of the latest GAS SAFETY (INSTALLATION & USE) REGULATIONS This appliance MUST be used in accordance with those, particularly so in respect of the need for regular servicing. See also the sections of this manual referring to Cleaning and General Maintenance. Safety Note This appliance is intended for professional use and shall only be used by qualified personnel. Parts and surfaces of this appliance get hot in use. It is the responsibility of the kitchen supervisor to inform and warn every user and kitchen worker of this and, furthermore, to ensure those users wear and use protective clothing when operating the appliance. Should any adjustment or attention be necessary, you are advised to contact your nearest CORGI (Confederation for the Registration of Gas Installers) Service Engineer immediately. The need for regular servicing is detailed in the latest GAS SAFETY (INSTALLATION & USE) REGULATIONS IF YOU THINK THAT GAS IS ESCAPING, ACT IMMEDIATELY. SHUT OFF THE GAS SUPPLY AT THE METER OR EMERGENCY CONTROL, CONTACT THE SUPPLIER OF YOUR GAS IMMEDIATELY. MAKE SURE THAT ALL USERS OF THIS APPLIANCE KNOW WHERE THE GAS SUPPLY STOPCOCK IS LOCATED FOR THE USE IN AN EMERGENCY. Improvements The policy of Viscount Catering Ltd is such that each product is subject to continual improvement. The company reserves the right to alter the design of any appliance without prior notification and without the responsibility to update any delivered or in-service appliance and, furthermore, without incurring the responsibility for altering these instructions. In such circumstances, it may be found that the appliance detailed herein differs in certain respect from the one supplied. For further details or enquires please contact: Viscount Catering Limited, Provincial Park, Nether Lane, Ecclesfield, Sheffield, S35 9ZX Tel: +44 (0) Fax:+44 (0) Manual Part No: Gas Water Boiler - 11

12 Users Instructions (cont.) Before Operating the Boiler 1) Ensure that the water supply is turned on. 2) Before lighting the boiler from cold, open the draw-off tap and drain any still water that has remained in the boiler from the previous use. This will enable boiling water quantities to be available faster and will replace de-aerated water. 3) Close the draw tap off. Operation 1) Turn on the gas supply. 2) Press the White button (RH side rear) and apply a lighted taper to the centre ribbon (maintenance flame) of the burner. 3) Hold button depressed for a further 20 seconds to establish flame. 4) If flame is extinguished on releasing button, repeat steps 2 & 3. Note: When first lighting the appliance after installation or after an extended shut-down period, it may be necessary for the White button to remain depressed for some time before the pilot will light, owing to presence of air in gas line. 5) With a vessel under the draw- off tap, pull down the handle and the rest of the burner should now light. Important Notes 1) If the gas cock is turned off or the flames are extinguished for any reason, WAIT 3 MINUTES BEFORE ATTEMPTING TO RE-LIGHT. 2) DO NOT obstruct the steam vent on the boiler, it could be dangerous to do so. 3) There is a low water safety device in the form of a float in the built in cistern. If there is a shortage of water the gas will be cut off automatically. It will not be possible to re-light the boiler until the water supply is resumed. Output The maximum delivery is shown in the table: Available for rapid draw-off after Continuous delivery per Initial Pre-heat Time pre-heating hour (Minutes) PINTS LITRES PINTS LITRES 3 Continuous draw-off Note: The above figures depend on local conditions and correct maintenance and are subject to manufacturing tolerances and periodic de-scaling in hard water areas. Manual Part No: Gas Water Boiler - 12

13 Users Instructions (cont.) Service The Installation Engineer should leave the appliance in good working order, however, in the event of transit damage or the failure of any part to operate during the warranty period, IT SHOULD BE REPORTED PROMPTLY to the installer or supplier, giving the details stamped on the Data Plate and the date of installation. The Data Plate is located at the bottom front corner on the right hand side. Note: In hard water areas, it is essential when the boiler is installed to arrange regular service visits to prevent damage caused by the build up of scale inside the boiler. This should be carried out by an experienced and competent Service Engineer- THIS WORK IS NOT COVERED BY THE GUARANTEE AS IT IS BEYOND OUR CONTROL. For the details of your nearest Service Agent for all warranty, repair and de-scaling work, you should contact: - The Service Manager, Viscount Catering Limited Provincial Park Nether Lane Ecclesfield Sheffield S35 9ZX Tel: +44(0) Fax:+44(0) Spares can be obtained via the Spare Parts Department at the above address (see illustrated Spare Parts list at the rear of this manual). Daily Cleaning 1) Wipe down the exterior surfaces with a cloth moistened with hot water and detergent. Rinse off using a cloth moistened with clean water and dry with a soft cloth. 2) DO NOT use abrasives. 3) DO NOT use wire wool. 4) DO NOT clean the appliance using a steam jet or water jet. 5) Proprietary cleaning pads may be used with care for removing heavy deposits if necessary. Manual Part No: Gas Water Boiler - 13

14 SERVICE AND MAINTENANCE Index Page Index 14 Technical Description 15 Fault Finding Service Instructions: To Remove Outer Case Lid 19 To Remove Top Trim 19 To Remove the Gas Toggle Valve 19 Leakage from the Gas Toggle Valve 19 To Adjust Gas Toggle Valve 20 To Drain the Boiler 20 To Remove Cistern (Cold Water Feed Tank) 20 To Adjust the Water Level 21 To Replace Float Valve Diaphragm 21 To Remove Heat Exchanger and Circulating Sleeve 21 To Remove Thermocouple 21 To Remove Main Burner 22 To Remove Inner Sleeve 22 To Replace Outer Case 22 To Remove the Gas Control Train (Relay, FFD and Governor) 23 To Replace the Relay Valve Diaphragm 23 To Replace FFD Valve Solenoid 23 To Test the Operating Gas Pressure 23 To Adjust Operating Gas Pressure 24 To Remove the Low Water Cut Out Float 24 To Dismantle Boiling Water Draw Off Tap 24 General Notes on Descaling 25 To Convert NG Appliance to LP Gas 26 To Convert LP Appliance to NG 26 Manual Part No: Gas Water Boiler - 14

15 Service and Maintenance (cont.) Technical Description The boiler is fitted with a highly efficient heat exchanger which will maintain a continuous flow of boiling water (self feeding from a built in cistern), low water safety cut-out and automatic gas control. The gas is controlled by means of a governor controlling the operating gas pressure; a flame failure device (FFD) operated by the maintenance flame (centre ribbon) and a relay valve operated by a toggle valve mechanically linked to the boiling water draw-off tap handle. A fixed by-pass (maintenance rate) is incorporated into the FFD, which maintains the correct temperature of the water if the boiler is standing unused for long periods. Models are available for operation on both Natural and LP Gas. Manual Part No: Gas Water Boiler - 15

16 Service and Maintenance (cont.) Fault Finding Symptoms Fault Remedy Overboiling. Scale in boiling chamber. Descale. Defective toggle valve. Replace. Loose scale or dirt in draw-off tap. Clean draw-off tap. (Section 21) Broken spring in draw-off tap. Replace spring. (Section 21) Spindle defective in draw-off tap. Replace spindle. (Section 21) Water level too high. Adjust water level to level mark in Cistern. Gas pressure set too high. Adjust gas governor. (Section 19) Not delivering rated output. Gas pressure incorrect. Adjust gas governor. )Section 19) Draw-off tap not opening fully. Replace defective parts. (Section 21) Water level low. Adjust water level to level mark in cistern. Partial blockage of feed from Clean out. cistern. Float valve partly blocked. Clean valve. (Section 9) Not delivering boiling water. Steaming and no water being delivered. Water pressure low. Water flooding boiler chamber. Leaking soldered joints in boiling chamber. Water space between boiling chamber and heat exchanger blocked. Blockages in cistern trap (London Loop). Mains water supply turned off. Refer to installer. Adjust water level to level Repair or replace. (Section 9) Descale. (Section 22) Clean. (Section 7) Turn on. Float valve blocked. Clean. (Section 9) Manual Part No: Gas Water Boiler - 16

17 Service and Maintenance (cont.) Fault Finding (cont.) Symptoms Fault Remedy Main burner remains Dirt in float valve. Clean on. Float defective. Replace float valve. (Section 9) Float valve washer worm. Replace float valve. (Section 9) Float valve insert defective. Replace float valve. (Section 9) Waterways scaled up. Descale. (Section 22) Boiling when on bypass. Restrictor missing from by-pass Replace. pipe. Relay valve not closing. Rectify. (Section 16) Centre ribbon (maintenance flame) will not stay alight. Governor not set to correct pressure. Fault connection at thermocouple FFD valve. Thermocouple incorrectly positioned. Thermocouple defective. FFD Valve defective. Float set to low Adjust governor. (Section 19) Remake connection. (Section 11) Reposition thermocouple. Replace. Replace solenoid coil or valve. Reposition float to correct level. Main burner will not light Electric float switch faulty. Check continuity and connections. Replace if necessary. Relay valve bleed hole blocked. Clean relay valve. Gas toggle valve not opening. Adjust toggle valve. (Section 5) Gas feed tubes blocked. Dismantle tubes and clean. Main burner remains on. Gas toggle valve not closing. Adjust toggle valve. (Section 5) Gas leak on union. Rectify. Dirt on relay valve seating. Relay valve diaphragm split. Clean relay valve. Replace diaphragm. Manual Part No: Gas Water Boiler - 17

18 Service and Maintenance (cont.) Fault Finding (cont.) Symptoms Fault Remedy Water leaking onto main burner. Heat exchanger leaking. Replace. (Section 10) Overboiling. See Section 1 Fault Finding. Cold water feed pipes vibrating. Loose pipework to feed cistern. Loose jumper in stop tap. Refer to installer. Refer to installer. Flame does not extinguish when water is turned off. Electric float switch is faulty. Replace. (Section 20) Electric float switch is in the wrong Reposition float so that it attitude. hangs downwards. (Section 20). Short on thermocouple between spade Remove short or replace. connections. (Section 11) Faulty electromagnetic unit in FFD. Examine repair/free off or replace as necessary. (Section 17) Manual Part No: Gas Water Boiler - 18

19 Service and Maintenance (cont.) ENSURE MAINS GAS AND WATER SUPPLIES ARE TURNED OFF BEFORE COMMENCING SERVICING 1) To Remove Outer Case Lid a) Lift at rear of lid. b) Slide lid forward and lift clear. c) Replace in reverse order. Ensure the lip on lower front of outer case lid fits under the lip on the top trim. 2) To Remove Top Trim a) Remove outer case lid (Section 1). b) Remove the two M5 nuts and shakeproof washers. c) Lift the gas toggle valve lever and withdraw trim. d) Replace in reverse order. 3) To Remove the Gas Toggle Valve a) Remove the top trim (Section 2). b) Disconnect the two gas compression unions from the gas toggle valve. c) Ease the gas pipes away from the gas toggle valve. d) Slacken the locknut and turn the boiling water draw off tap so that it is horizontal. e) Hinge the gas toggle valve lever down so that it is vertical to the valve. f) Remove the hexagon locknut and shakeproof washer securing the gas toggle valve to its bracket. Detach valve. g) Replace in reverse order ensuring boiling water draw off tap is returned to its vertical position and that it operates the gas toggle valve lever when the tap is opened. 4) Leakage from the Gas Toggle Valve Should any problems due to leakage of gas, or mechanical breakage, is experienced with the toggle IT SHOULD BE REPLACED COMPLETELY. Manual Part No: Gas Water Boiler - 19

20 Service and Maintenance (cont.) 5) To Adjust Gas Toggle Valve a) Remove top trim (Section 2). b) Slacken the four Pozi drive screws securing the gas toggle valve bracket to the outer case. c) Ease the bracket up or down as required. d) Tighten the four Pozi drive screws. NOTE: There is only slight adjustment. 6) To Drain the Boiler a) Switch off the water supply. b) Remove outer case lid (Section 1). c) Insert a rubber hose down the cistern trap (London Loop). d) Siphon as much water as possible from the boiler. e) Disconnect the mains water supply union from the cistern ball valve. f) Disconnect the overflow pipe if fitted. g) Disconnect the mains gas union at the boiler gas stopcock. h) Lift the boiler at the front. Tilt the top back and withdraw counter tray from below base members (legs). i) Lift the boiler from its stand and invert it over a sink, to remove an water remaining in the boiling chamber. j) Replace in reverse order. 7) To Remove Cistern (Cold Water Feed Tank) a) Drain the boiler (Section 6a to e). b) Remove the outer case by undoing the six outer case screws and lifting the panel to the left of the appliance. c) Remove riser from bottom of cistern or alternatively disconnect the 15mm union at the cold water feed nosepiece at the rear of the boiler below cistern. d) Remove the two M5 x 25mm screws securing the cistern to the top of the outer case. Detach the cistern. e) Replace in reverse order. Ensure new packing washers are fitted where required, between the cistern and cistern trap. Manual Part No: Gas Water Boiler - 20

21 Service and Maintenance (cont.) 8) To Adjust the Water Level a) With the mains water supply turned on check the water level against the level indicator inside the cistern. b) Rotate Float spindle to adjust water level if required. 9) To Replace Float Valve Diaphragm a) Remove outer case (Section 1) b) Turn off water, disconnect water feed pipe from float valve remove back nut and washer, pull valve away from cistern. Replace in reverse order. c) To clean filter, remove float, unscrew retaining nut and remove arm and front cap assembly. Remove diaphragm and filter, wash filter and assemble valve in reverse order, ensuring filter is pushed fully back over it s slot, hand tighten only. 10 To Remove Heat Exchanger and Circulating Sleeve a) Drain broiler (Section 6). Remove cistern (Section 7). b) Remove cold water feed nose-pipe from rear of boiler by unscrewing it anti-clockwise. c) Remove the boiling water draw off tap by unscrewing the hexagon locknut. d) Remove the draw off tap nosepiece. Unscrew nosepiece anti-clockwise taking care not to mark the front of the boiler. e) Lift out the circulating sleeve from the heat exchanger. Note the position of the three locating lugs fitting into the slots on the top edge of the inner sleeve. 11) To Remove Thermocouple a) Remove the rear panel and outer case lid (Section 1 & 7b). b) Disconnect the low water cut out float from the thermocouple. c) Remove the two M5 screws securing the access cover to the lower front panel d) Disconnect the thermocouple from below the flame failure device. e) Remove the two hexagonal screws from the clamping bracket and lift off the bracket front. Lift out the thermocouple. f) Replace in the reverse order. Note the positioning of the flats and recesses on the components when reassembling. Manual Part No: Gas Water Boiler - 21

22 Service and Maintenance (cont.) 12) To Remove the Main Burner a) Drain the boiler (Section 6) and disconnect water feed, overflow and gas feed pipes ensuring supplies are isolated. b) Remove the thermocouple (Section 11). c) Invert the boiler. d) Disconnect the maintenance injector pipe located at the rear of the main burner. e) Disconnect the compression union fitted into the side of the main burner. f) Disconnect the 15mm compression union at the relay valve. g) Remove the two M5 screws and washers securing the burner to the bottom of the outer case. Detach burner. Replace in reverse order. 13) To Remove Inner Sleeve a) Remove heat exchanger and circulating sleeve (Section 10). b) Remove main burner (Section 12). c) Turn the boiler the correct way up. d) Turn the inner sleeve so that the lower positioning bracket s attached to the lower edge of the sleeve clear the outer case lip. Lift the sleeve up and remove from top. Replace in reverse order. 14) To Replace Outer Case a) Remove heat exchanger and circulating sleeve (Section 10). b) Remove main burner (Section 12). c) Remove inner sleeve (Section 13). d) Lift out outer sleeve. e) Remove the four M5 screws securing the gas toggle valve bracket to the outer case. f) Remove the gas supply pipes connecting the gas toggle valve to the gas controls and main burner. g) Replace in reverse order. Manual Part No: Gas Water Boiler - 22

23 Service and Maintenance (cont.) 15) To Remove the Gas Control Train (Relay, FFD and Governor) a) Remove the lid and the outer case. b) Switch off and disconnect the supplies. c) Disconnect the thermocouple from below the FFD valve. d) Disconnect the compression union from the top of the relay valve. e) Remove the inlet and outlet 15 mm compression unions. f) Detach the control train for examination. Before splitting the parts note their arrangement and the angles made between them. g) Replace in the reverse order. 16) To Replace the Relay Valve Diaphragm a) Remove the lid and outer back. b) Disconnect the union on the top of the valve. c) Remove the four screws securing the top of the relay valve. d) Detach the top of the valve and lift out the diaphragm. e) Fit new diaphragm and replace in reverse order. 17) To Replace FFD Valve Solenoid a) Disconnect the thermocouple from below the FFD valve. b) Unscrew the hexagon plug from bottom of FFD valve. c) Withdraw solenoid. d) Fit new solenoid and replace parts in reverse order. 18) To Test the Operating Gas Pressure a) Remove the hexagon headed screw from the test point. b) Fit a flexible tube to test point and connect it to a manometer (U tube). c) Turn on the main s gas and light the boiler. d) Open the boiling water draw off tap and position a container under the nozzle spout. e) Check that the burner is full on. The pressure at the manometer should be 3.8 wg (9.6 mbar). g) Close the boiling water draw off tap. Turn the gas off. Remove the tube and refit the hexagon screw to pressure point. Manual Part No: Gas Water Boiler - 23

24 Service and Maintenance (cont.) 19) To Adjust Operating Gas Pressure a) Proceed as in Section 18. b) Remove the cap nut on the governor. c) To increase the pressure turn the screw clockwise. To decrease the pressure turn it anticlockwise. d) Secure the cap nut after adjusting the governor. 20) To Remove the Low Water Cut Out Float a) Switch off the supplies. b) Remove the lid and outer case back. c) Remove the push on tags from the thermocouple. d) Undo the back nut and remove the float. e) Replace in the reverse order. 21) To Dismantle Boiling Water Draw Off Tap a) Open draw off tap and drain water from collecting box. b) Slacken the locknut and turn the draw off tap through 90. c) Unscrew bonnet and lift out upper assembly. (If changing the seat cup only, pull it off the stem and press on a new one. Replace the upper assembly). d) With the seat cup attached to the upper assembly place the seat cup in the palm of the hand, press down with the fingers on top of the cam thus compressing the spring. Push out the handle pin with a small screwdriver from the hole in the cam. e) Remove the spring from the stem. f) Detach the seat cup from the stem by pulling it off. g) Replace in reverse order, fitting new parts as required. Note: The handle pin must be fitted as shown. Manual Part No: Gas Water Boiler - 24

25 Service and Maintenance (cont.) 22) General Notes on De-scaling If hard water is used, it is essential that the boiler should be de-scaled at regular intervals, depending on the hardness and usage of the boiler. As a general rule, complete de-scaling should take place every three months. Dismantling the appliance and removing the scale by mechanical means. The use of a chemical solvent is not recommended except in the special case mentioned later in these instructions. A coating of scale will lower the efficiency and shorten the life of the heat exchanger if it is not removed. The heaviest deposits of scale will be found in the following places: a) The bore of the draw off tap. b) The boiling water collecting box. c) On the inside of the heat exchanger. d) The cistern trap (London Loop) and union. To De-scale the Boiler a) Remove the heat exchanger and circulating sleeve (Section 10). b) Remove any scale from inside the heat exchanger by gently chipping it off. Ensure all the scale is removed from the base. Wash away any loose scale with cold water. c) Remove the scale from the circulating sleeve and ensure the vent pipe in the collecting box is clear. d) The cold water feed and draw off tap nosepieces may be drilled out with a suitable sized masonry drill to clear the scale. e) The cistern trap can be cleared by using a drill on an extended handle, it is very important that the cistern trap is cleared of any scale. f) The boiling water draw off tap may be immersed in a solution made with a proprietary brand of descalant. Immersion should not be prolonged beyond the time necessary to allow the scale to be removed. It should be noted that this method of de-scaling is suitable for lightly scaled items only. g) After de-scaling, all the components should be swilled in cold water. h) Replace in reverse order. Manual Part No: Gas Water Boiler - 25

26 Service and Maintenance (cont.) 23) To Convert NG Appliance to LP Gas a) Remove the lid and the outer case. b) Switch off and disconnect the supplies. c) Remove burner (Section 12) and fit replacement LP burner, (200289) complete with 0.82mm injectors and 0.55mm by-pass injector. d) Disconnect gas supply pipe to governor and remove. e) Disconnect governor from FFD. f) Fit new gas supply pipe and union. 24) To Convert LP Appliance to NG a) Remove the lid and outer case. b) Switch off and disconnect the supplies. c) Remove burner (Section 12) and fit replacement NG burner, (200290) complete with 1.5mm injectors and 0.82 mm by-pass injector. d) Disconnect gas supply pipe union. e) Fit replacement gas governor, elbow and gas supply pipe. d) Adjust gas pressure (Section 19). Manual Part No: Gas Water Boiler - 26

27 SPARE PARTS LIST Item No. Description Part No. 1 Outer Back & Side Panel Gas Cock Gas Inlet Pipe NG a Gas Inlet Pipe LP BO 3b Straight Adapter - LP Elbow 15 mm x ½ BSP Burner Gas Inlet Pipe Assembly a Pressure Test Nipple X Governor (½ ) NG X Flame Failure Device (FFD) X Relay Valve Elbow ½ BSP Iron Stud Elbow 3 / 16 x 1 / 8 BSP Base Member LH Base Member RH Supply Pipe Support Strap Thermocouple Thermocouple Bracket Burner Assembly NG a Burner Assembly LP Burner Supply Pipe Support Access Hole Cover Assembly Draw Off Tap Assembly & Nozzle a Draw Off Tap Assembly w/o Nozzle b Tap Stem c Tap Spring d Tap Handle e Tap Handle Pin f Tap Seat Cup g Nozzle Assembly c/w Locknut h Nozzle Locknut Only Outer Case Assembly Outer Sleeve Top Trim Toggle Valve Bracket Toggle Valve Assembly with Lever a Toggle Valve Lever b Lever Locating Pin c Locknut ¼ BSP d Stud Coupling 1 / 8 x 3 / e Compression Nut 3 / Manual Part No: Gas Water Boiler - 27

28 Spare Parts List (cont.) Item No. Description Part No. 26 Inner Sleeve Assembly Heat Exchanger Assembly Nose Piece for Draw Off Tap a C Ring b Coupling Nut Circulating Sleeve/Collecting Box Heat Exchanger Lid Assembly Outer Case Lid Float Valve Side Panel Cistern Overflow Cistern Assembly Low Level Water Indicator Straight Coupling 15 mm x ½ BSP a Riser b Sealing Washer Trap Assembly Un-plated Plug 1 / 8 BSP a Seating Washer for Plug Elbow 15 mm x ½ BSP Water Inlet Nose Piece a Sealing Washer Counter Tray Straight Coupling Items Not Illustrated 50 Fascia Panel Fixing Plate Supply Tube Assembly 51 Toggle Valve to Relay Valve Toggle Valve to Inlet Adapter FFD to Maintenance Injector Spares Kits Conversion Kit NG to LPG G31 Conversion Kit LPG to NG G32 Manual Part No: Gas Water Boiler - 28

29 Spare Parts List (cont.) Manual Part No: Gas Water Boiler - 29

30 Spare Parts List (cont.) Spare Parts available from: Viscount Catering Ltd Provincial Park Nether Lane Ecclesfield Sheffield S35 9ZX Tel: +44 (0) Fax: +44 (0) Manual Part No: Gas Water Boiler - 30

31 ACCESSORIES XB XB XB XB XBJE-DCV Stand Assembly Drip Tray Swivel Arm Extension 300mm Swivel Arm Extension 230mm Double Check Valve Manual Part No: Gas Water Boiler - 31

32 VISCOUNT CATERING LIMITED WARRANTY COVER The Company offer twelve months warranty with each new piece of equipment subject to our normal conditions of sale and will undertake responsibility for warranty subject to the additional following conditions. Notice of the defect/damage is given within 48 hours of breakdown or in the case of damage four days from the date of despatch and the manufacturer given adequate opportunity to examine the goods in order that appropriate action can be taken. The Company will not be obliged to repair or replace any goods if after examination the defect/damage is found to be through accident, misuse, neglect, incorrect installation or maintenance by other than approved engineers, or any other cause beyond the reasonable control of the manufacturer. EXCLUSIONS TO WARRANTY Normal routine maintenance is not covered and the warranty specifically excludes any problems, which are related to scale caused by hard water and the cleaning of pilot jets. Also excluded from the warranty are the following consumable items. Tap washers and springs, gaskets, oven lamps and indicating lights, door seals and any other perishable parts. This warranty in no way prejudices your rights under common law and is offered as an addition to your statutory rights. Manual Part No: Gas Water Boiler - 32

ELECTRIC WATER BOILER

ELECTRIC WATER BOILER JJ3 ELECTRIC WATER BOILER OWNER S MANUAL Click here for Parts List Manual Part No: 930150-01 Electric Water Boiler - 1 Model No. Product Description Rev. Date Jackson Junior Boiler JJ3 Jackson Junior Boiler

More information

GAS STEAMER MV 1 SERIES OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

GAS STEAMER MV 1 SERIES OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE MV 1 SERIES GAS STEAMER OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 931762-01 MV1 Gas Steamer - 1 Model No. Product Description Rev. Date Flexible Hose Size

More information

GAS GRILL HEAVY DUTY OWNER S MANUAL. Part List. Click here for. Country of Destination GB and IE

GAS GRILL HEAVY DUTY OWNER S MANUAL. Part List. Click here for. Country of Destination GB and IE HEAVY DUTY GAS GRILL OWNER S MANUAL Click here for Part List Country of Destination GB and IE Manual Part No: 930010-01 HD Gas Grill - 1 IMPORTANT CUSTOMER INFORMATION Please check the gas tap and thermostat

More information

GAS GRILL MEDIUM DUTY OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

GAS GRILL MEDIUM DUTY OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE MEDIUM DUTY GAS GRILL OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 930006-01 MD Gas Grill - 1 IMPORTANT CUSTOMER INFORMATION Please check the gas tap and thermostat

More information

MEDIUM DUTY ELECTRIC FRYER OWNER S MANUAL. Click here for. Parts List. Manual Part No: MD Electric Fryer - 1 Manual Rev No: 1

MEDIUM DUTY ELECTRIC FRYER OWNER S MANUAL. Click here for. Parts List. Manual Part No: MD Electric Fryer - 1 Manual Rev No: 1 MEDIUM DUTY ELECTRIC FRYER OWNER S MANUAL Click here for Parts List Manual Part No: 930155-01 MD Electric Fryer - 1 Model No. Product Description Rev. Date Electric Fryers MLE30F-F 300 Fryer 2 09/03/00

More information

OG7302 Salamander Grill

OG7302 Salamander Grill OG7302 Salamander Grill USER, INSTALLATION, SERVICING AND CONVERSION INSTRUCTIONS For use in GB & IE IS370 ECN3280 1 Dear Customer, Thank you for purchasing this Lincat product. This is just one of over

More information

GAS GENERAL PURPOSE SOLID TOP RANGES

GAS GENERAL PURPOSE SOLID TOP RANGES MV 1 SERIES GAS GENERAL PURPOSE SOLID TOP RANGES OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 931545-02 MV1 Gas Solid Top Range - 1 IMPORTANT CUSTOMER INFORMATION

More information

GAS FRYER MV 1 SERIES OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

GAS FRYER MV 1 SERIES OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE MV 1 SERIES GAS FRYER OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 931760-01 MV1 Gas Fryer - 1 Model No. Product Description Rev. Date Flexible Hose Size MV

More information

GAS FRYER G Version MEDIUM DUTY OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE

GAS FRYER G Version MEDIUM DUTY OWNER S MANUAL. Click here for Parts List. Country of Destination GB and IE MEDIUM DUTY GAS FRYER G Version OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 931983-01 MD Gas Fryer - 1 Model No. Product Description Rev. Date Flexible Hose

More information

GARLAND GAS STEAK GRILL OWNER S MANUAL. Click here for Part List. Country of Destination GB and IE

GARLAND GAS STEAK GRILL OWNER S MANUAL. Click here for Part List. Country of Destination GB and IE GARLAND GAS STEAK GRILL OWNER S MANUAL Click here for Part List Country of Destination GB and IE Manual Part No: 932067-06 Gas Steak Grill - 1 IMPORTANT CUSTOMER INFORMATION Please check the gas tap will

More information

GARLAND GAS CHARGRILL OWNER S MANUAL. Country of Destination GB and IE. Manual Part No: Gas Chargrill - 1 Manual Rev No: 1

GARLAND GAS CHARGRILL OWNER S MANUAL. Country of Destination GB and IE. Manual Part No: Gas Chargrill - 1 Manual Rev No: 1 GARLAND GAS CHARGRILL OWNER S MANUAL Country of Destination GB and IE Manual Part No: 932067-08 Gas Chargrill - 1 IMPORTANT CUSTOMER INFORMATION Please check that the gas taps will press and release freely

More information

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592 User, Installation and Servicing Instructions Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592 INSTALLATION AND SERVICING INSTRUCTIONS Please read the following carefully before commencing work on

More information

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations. G3512 and G3532 DOMINATORPLUS Grills INSTALLATION and SERVICING INSTRUCTIONS This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

More information

GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7

GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7 Page 1 of 17 GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7 SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PARTS

More information

GAS GENERAL PURPOSE OPEN TOP RANGES

GAS GENERAL PURPOSE OPEN TOP RANGES GARLAND GAS GENERAL PURPOSE OPEN TOP RANGES OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 932067-01 Gas Open Top Range - 1 IMPORTANT CUSTOMER INFORMATION Please

More information

PARAGON GAS FRYER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL : PDGF/PDGFP

PARAGON GAS FRYER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL : PDGF/PDGFP Page 1 of 13 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS FRYER MODEL : PDGF/PDGFP Page 2 of 13 IMPORTANT PLEASE READ INSTRUCTIONS FULLY BEFORE USE MODEL PDGF FRYER & PDGFP

More information

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations. G350/11 and 12 FREESTANDING FRYERS INSTALLATION and SERVICING INSTRUCTIONS These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

More information

User, Installation, Servicing and Conversion Instructions. Opus 700 Gas Oven Ranges OG7001 & OG7002 IS431 ECN3592

User, Installation, Servicing and Conversion Instructions. Opus 700 Gas Oven Ranges OG7001 & OG7002 IS431 ECN3592 User, Installation, Servicing and Conversion Instructions Opus 700 Gas Oven Ranges OG7001 & OG7002 IS431 ECN3592 Dear Customer, Thank you for purchasing this Lincat product. This is just one of over 450

More information

USHO COOKER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: USHO. INSTRUCTION REF: IN152 ISSUE No. 4 DATE

USHO COOKER INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: USHO. INSTRUCTION REF: IN152 ISSUE No. 4 DATE Page 1 of 11 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS USHO COOKER MODEL: USHO Page 2 of 11 WARNING To avoid scratching the highly polished exterior surface of this equipment whilst

More information

MV 1 SERIES GAS CONVECTION OVEN OWNER S MANUAL. Country of Destination GB and IE

MV 1 SERIES GAS CONVECTION OVEN OWNER S MANUAL. Country of Destination GB and IE MV 1 SERIES GAS CONVECTION OVEN OWNER S MANUAL Click here for Parts List Country of Destination GB and IE Manual Part No: 931798-02 MV1 Gas Convection Oven - 1 Model No. Product Description Rev. Date Flexible

More information

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National

More information

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE G1808X, G1838X, G1848X DEEP FAT FRYERS INSTALLATION and SERVICING INSTRUCTIONS These appliances must only be installed, serviced and converted for use with other gases by a competent person as stipulated

More information

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate. DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Opus 800 Gas Boiling Tops OG8003, OG8004 & OG8009 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:

More information

This appliance must be installed and serviced by a competent person as stipulated by the

This appliance must be installed and serviced by a competent person as stipulated by the DOMINATORPLUS GAS RANGE APPLIANCES (Refer to Section 1.1 for models covered by this document) INSTALLATION and SERVICING INSTRUCTIONS This appliance must be installed and serviced by a competent person

More information

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

MULTIPOINT BF Gas Fired Balanced Flue Water Heater Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 (03.12) JS Natural Gas Main Multipoint

More information

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use F900 SERIES User, installation and servicing instructions GAS CHARGRILL G9440, G9460, G9490, G94120 Read these instructions before use DATE PURCHASED: MODEL NUMBER: SERIAL NUMBER: DEALER: SERVICE PROVIDER:

More information

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200 Page 1 of 17 GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION

More information

Installation & Service Instructions

Installation & Service Instructions Part No. 966/9350/1 02 Potterton Housewarmer Illusion ASD - G.C. NO. 37 590 16 966 Inset DGF with ILLUSION FACIA Potterton Housewarmer Stratton ASD - G.C. NO. 37 590 17 966 Inset DGF with STRATTON FACIA

More information

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974 FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974 163 Dukes Road London UK W3 0SL www.clayovens.com Tel: +44 208 896 2696 Fax: +44 208 8962686

More information

chaffoteaux ltd. CORVECELT TS CONFORMS WITH EUROPEAN (BS5386Ptl) EN26 installation servicing requirements

chaffoteaux ltd. CORVECELT TS CONFORMS WITH EUROPEAN (BS5386Ptl) EN26 installation servicing requirements chaffoteaux ltd. CORVECELT TS CONFORMS WITH EUROPEAN (BS5386Ptl) STANDARD EN26 installation servicing requirements contents Page 3 : TECHNICAL DATA Pages 4 and 5 : INSTALLATION Pages 6 and 7 : SERVICING

More information

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592 User, Installation and Servicing Instructions Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592 Dear Customer, Thank you for purchasing this Lincat product. This is just

More information

USERS, INSTALLATION AND SERVICING INSTRUCTIONS

USERS, INSTALLATION AND SERVICING INSTRUCTIONS USERS, INSTALLATION AND SERVICING INSTRUCTIONS GAS BRATT PAN G3800 and G3800DX DATE PURCHASED: MODEL NUMBER: SERIAL NUMBER: DEALER: SERVICE PROVIDER: T100753 Rev. 3 Published: 04 /10/2012 Dear Customer,

More information

KEY TO COMPONENTS. 1. Heat exchanger 2. Pilot gas pipe 3. Gas injector nozzle 4. Measuring point

KEY TO COMPONENTS. 1. Heat exchanger 2. Pilot gas pipe 3. Gas injector nozzle 4. Measuring point Bosch Thermotechnik WR 325 BF Gas Fired Multipoint Water Heater INSTALLATION AND SERVICING INSTRUCTIONS GC NUMBER 52 311 01 For your safety if you smell gas: 3. Do not operate any electrical switches 1.

More information

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( ) SERVICE MANUAL Ecoboiler Model range: T20 (1000662) T30 (1000663) Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland

More information

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE G1808X, G1838X, G1848X DEEP FAT FRYERS INSTALLATION and SERVICING INSTRUCTIONS These appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use)

More information

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396 User and Installation Instructions Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396 Please read the following carefully before using this appliance. Warnings and Precautions Please ensure that

More information

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Thank you

More information

Glen Dimplex Professional Appliances: Salamander Grill (GB/IE)

Glen Dimplex Professional Appliances: Salamander Grill (GB/IE) Glen Dimplex Professional Appliances: Salamander Grill (GB/IE) This appliance must be installed by a competent person in compliance with the installation and servicing instructions and national regulations

More information

HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT

HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT CAUTION These instructions must be read and understood before proceeding with the installation and to avoid any possibility of accident it is essential

More information

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ecoboiler T20 & T30 SERVICE MANUAL Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland Fax: (01) 295 3715 UK Tel:

More information

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461 User and Installation Instructions Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461 Dear Customer Thank you for purchasing this Lincat product. With correct use and careful maintenance as described

More information

GAS TARGET TOP / STATIC OVEN RANGE

GAS TARGET TOP / STATIC OVEN RANGE INSTALLATION AND OPERATION MANUAL GAS TARGET TOP / STATIC OVEN RANGE G570 For use in GB & IE 230096-8 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty

More information

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No 53 416 06 Publication No. ZZ 180/17 May 2000 These appliances are tested and certified by B G Technology for

More information

VULCAN GAS RANGES RG-6 OPEN BURNER

VULCAN GAS RANGES RG-6 OPEN BURNER VULCAN GAS RANGES RG-6 OPEN BURNER Index: General data 2 Owner s Responsibility 3 authorised Vulcan catering Equipment Branches and dealers 3 Parts Ordering / Service Information 4 Prior to Installation

More information

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER Page 1 of 9 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER MODEL : 7072 & 7073 Page 2 of 9 WARNING To avoid scratching the highly polished exterior surface of this

More information

OG7005 Solid Top Gas Oven Range

OG7005 Solid Top Gas Oven Range OG7005 Solid Top Gas Oven Range USER, INSTALLATION, SERVICING AND CONVERSION INSTRUCTIONS For use in GB & IE IS323 ECN3145 1 Dear Customer, Thank you for purchasing this Lincat product. This is just one

More information

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING. 21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING www.anvilworld.com 20 ALL ANVIL EQUIPMENT COMES WITH A ONE YEAR WARRANTY ON COMPONENTS AND DEFECTIVE WORKMANSHIP. www.anvilworld.com 19 20 LITER

More information

Manual / Handbuch Spare parts list / Ersatzteilliste

Manual / Handbuch Spare parts list / Ersatzteilliste Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a

More information

Gas Cooktops (450mm Wide Hobs)

Gas Cooktops (450mm Wide Hobs) Installation and Operation Manual Gas Cooktops (450mm Wide Hobs) Series RN8450G RNL8450G RNB8450G RNLB8450G RN8900G RNL8900G RNB8900G RNLB8900G Date Purchased Serial Number Dealer Service Provider For

More information

The Classeq under counter range

The Classeq under counter range Installation & Operators Manual The under counter range Part number 902.0011 Revision C Effective date January 2010 Language English Glasswashers Eco 1 Eco 2 Eco 3 Duo 2 Duo 3 Dishwasher Hydro 500 Hydro

More information

Installation, Operating and Servicing Instructions. Opus 800 Gas Open Top Oven Ranges OG8001 & OG8002

Installation, Operating and Servicing Instructions. Opus 800 Gas Open Top Oven Ranges OG8001 & OG8002 Installation, Operating and Servicing Instructions Opus 800 Gas Open Top Oven Ranges OG8001 & OG8002 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:

More information

INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B. For use in GB & IE

INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B. For use in GB & IE INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B For use in GB & IE 231920-8 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

CSP6 - Gas Stock Pot INSTALLATION AND OPERATION MANUAL

CSP6 - Gas Stock Pot INSTALLATION AND OPERATION MANUAL CSP6 - Gas Stock Pot INSTALLATION AND OPERATION MANUAL 240897-1 Moffat Limited Rolleston 7675 New Zealand AUSTRALIA Moffat Pty Limited E.Mail: vsales@moffat.com.au Main Office: (tel): +61 (03) 9518 3888

More information

Manual and Thermostatic Power Shower Units

Manual and Thermostatic Power Shower Units 520M/520TS Manual and Thermostatic Power Shower Units Installation instructions & User guide IMPORTANT: This booklet should be given to the customer after installation and demonstration. WARNING: Under

More information

Installation and Operation Manual. Gas Bratt Pan. Date Purchased. Serial Number. Dealer. Service Provider. For use in GB & IE

Installation and Operation Manual. Gas Bratt Pan. Date Purchased. Serial Number. Dealer. Service Provider. For use in GB & IE Installation and Operation Manual Gas Bratt Pan BP8080G BP8080GE BP8120G BP8120GE BPL8080G BPL8080GE BPL8120G BPL8120GE Date Purchased Serial Number Dealer Service Provider For use in GB & IE 228688-16

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Wall Mounted Water Boiler WMB3F/B,WMB3F/W Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer:

More information

OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS

OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS Please read the following carefully before using this appliance. Warnings and Precautions Please ensure that all commissioning checks and

More information

Gas Salamander. Model CS9 INSTALLATION AND OPERATION MANUAL. For use in GB & IE

Gas Salamander. Model CS9 INSTALLATION AND OPERATION MANUAL. For use in GB & IE Gas Salamander Model CS9 INSTALLATION AND OPERATION MANUAL For use in GB & IE 230628-7 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au

More information

Synergy Grill User & Engineer Installation & Conversion Guide

Synergy Grill User & Engineer Installation & Conversion Guide Synergy Grill 1300 User & Engineer Installation & Conversion Guide 1 Index: Description Page Number/Section Important Information 3 Installation 4-6 / Section 1 Commissioning 6 / Section 2 Converting Gas

More information

INSTALLATION AND OPERATION MANUAL GAS GRIDDLE TOASTER G55T. For use in GB & IE

INSTALLATION AND OPERATION MANUAL GAS GRIDDLE TOASTER G55T. For use in GB & IE INSTALLATION AND OPERATION MANUAL GAS GRIDDLE TOASTER G55T For use in GB & IE 228001-7 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au

More information

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS Belling Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS Note: This appliance is supplied for use with Natural Gas and can be converted to LPG

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

MHG201 Gas Hob Manual for Installation, Use and Maintenance

MHG201 Gas Hob Manual for Installation, Use and Maintenance MHG201 Gas Hob Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10 Page 1 of 18 GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION

More information

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer

More information

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This

More information

Installation & Operators Manual

Installation & Operators Manual Installation & Operators Manual Eco, Hydro and Duo under counter range Part number 902.0011 Revision A Installation and Operation instructions For Classeq under counter range of glass and dishwashers.

More information

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011 User and Installation Instructions Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011 USER / INSTALLATION INSTRUCTIONS Please read the following carefully before using this appliance. Warnings and

More information

GAS TARGET TOP RANGE/ CONVECTION OVEN

GAS TARGET TOP RANGE/ CONVECTION OVEN INSTALLATION AND OPERATION MANUAL GAS TARGET TOP RANGE/ CONVECTION OVEN G576 232427-8 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited E.Mail:

More information

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:-

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:- THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. THE MODELS COVERED ARE:- For use with Natural Gas:- KENT ESTATE NG, KENT ULTIMA NG For use with Liquid Propane Gas (LPG):- KENT ESTATE LP, KENT

More information

INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B. For use in GB & IE

INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B. For use in GB & IE om INSTALLATION AND OPERATION MANUAL GAS SALAMANDER G91 G91B For use in GB & IE 231920-11 MANUFACTURED BY Moffat Limited Rolleston 7675 New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web:

More information

Installation and Operation Manual. Gas Salamander SN8200G SN8200GB. Date Purchased. Serial Number. Dealer. Service Provider

Installation and Operation Manual. Gas Salamander SN8200G SN8200GB. Date Purchased. Serial Number. Dealer. Service Provider Installation and Operation Manual Gas Salamander SN8200G SN8200GB Date Purchased Serial Number Dealer Service Provider 232460-6 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS

More information

USER INSTRUCTION MANUAL. Autofill Water Boiler

USER INSTRUCTION MANUAL. Autofill Water Boiler USER INSTRUCTION MANUAL Autofill Water Boiler GH187 GC719 (FILTERED PRODUCT) Buffalo Warranty 1 Year Parts 1 Year Labour 083347300-03/06/14 Introduction Thank you for purchasing this Buffalo appliance.

More information

E32 CONVECTION OVEN SERVICE MANUAL -1- Revision 1/F3508

E32 CONVECTION OVEN SERVICE MANUAL -1- Revision 1/F3508 E32 CONVECTION OVEN SERVICE MANUAL -1- WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. -2- CONTENTS This manual is designed to take a more in depth look

More information

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm

More information

GAS TARGET TOP / STATIC OVEN RANGE

GAS TARGET TOP / STATIC OVEN RANGE INSTALLATION AND OPERATION MANUAL GAS TARGET TOP / STATIC OVEN RANGE G570 232426-8 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited E.Mail: vsales@moffat.com.au

More information

COAL EFFECT BALANCED FLUE GAS FIRE

COAL EFFECT BALANCED FLUE GAS FIRE Raglan COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. KBFC**MN for use on Natural Gas (G20) at a supply pressure of 20 mbar in

More information

User Instruction Manual

User Instruction Manual User Instruction Manual Export Electric Catering Urn Please read and keep these instructions These instructions cover the Burco 10, 20 and 30 litre electric catering urns for export SKU s 444441912, 444441913

More information

Target Monobloc Kitchen Mixer Chrome

Target Monobloc Kitchen Mixer Chrome Target Monobloc Kitchen Mixer Chrome Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan,

More information

The Professional s Choice

The Professional s Choice SureFlow compact range: 1000-C & 1000-M Auto-Fill Catering Water Boiler Installation And User Instructions The Professional s Choice CONTENTS CONTENTS & INTRODUCTION 2 SAFETY & ENVIRONMENTAL INFORMATION

More information

TC MODULE (FFD) (with Gas Hob)

TC MODULE (FFD) (with Gas Hob) TC MODULE (FFD) (with Gas Hob) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

HOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT

HOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT HOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT If the appliance does not operate correctly contact your supplier Or Leisure Products (Bolton) Ltd Holly Street, Bolton, BL1 8QR. England. ~~~~ For

More information

HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT

HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT CAUTION These instructions must be read and understood before proceeding with the installation and to avoid any possibility of accident it is essential

More information

Dovre 250 Cast Iron Gas Stove

Dovre 250 Cast Iron Gas Stove Dovre 50 Cast Iron Gas Stove NATURAL GAS AND LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS THIS PRODUCT IS FOR USE ONLY IN GREAT BRITAIN AND IRELAND These instructions are to be left with the customer,

More information

Gas Target Top Range Static Oven

Gas Target Top Range Static Oven Installation and Operation Manual Gas Target Top Range Static Oven RN8110G RNB8110G RNL8110G RNLB8110G Date Purchased Serial Number Dealer Service Provider 1 For use in GB & IE 228682-14 MANUFACTURED BY

More information

INSTALLATION AND OPERATION MANUAL GAS CHARGRILL G592 G593 G594 G596 G598. For use in GB, IE & DK

INSTALLATION AND OPERATION MANUAL GAS CHARGRILL G592 G593 G594 G596 G598. For use in GB, IE & DK ` INSTALLATION AND OPERATION MANUAL GAS CHARGRILL G592 G593 G594 G596 G598 For use in GB, IE & DK 228593-24 MANUFACTURED BY Moffat Limited Rolleston 7675 New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat

More information

E32 CONVECTION OVEN SERVICE MANUAL

E32 CONVECTION OVEN SERVICE MANUAL E32 CONVECTION OVEN SERVICE MANUAL Applies to units from S/N 40256-1- WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. -2- CONTENTS This manual is designed

More information

Installation and Operation Manual. Gas Target Top. Date Purchased. Serial Number. Dealer. Service Provider. For use in GB & IE

Installation and Operation Manual. Gas Target Top. Date Purchased. Serial Number. Dealer. Service Provider. For use in GB & IE Installation and Operation Manual Gas Target Top RN8100G RNL8100G RNB8100G RNLB8100G Date Purchased Serial Number Dealer Service Provider For use in GB & IE 228092-20 MANUFACTURED BY Moffat Limited Rolleston

More information

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY

More information

POWER SHOWERS Models 4500M 5002M 4500T 5002T

POWER SHOWERS Models 4500M 5002M 4500T 5002T II POWER SHOWERS Models 4500M 5002M 4500T 5002T Performance Shower Products CUSTOMER SERVICE HELPLINE: 01883 730339 CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY: This booklet covers all models in

More information

Gas Fire Patio Heater Q9

Gas Fire Patio Heater Q9 Gas Fire Patio Heater Q9 Instruction Manual Please read the manual BEFORE you unpack or install the fire TABLE OF CONTENTS Warning 3 Getting Started 4 What s Included 5 Assembly Procedures 6 Product Drawing

More information

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30 STREAMLINE OVERSINK Fitting Instructions and User Guide 1 36005997_iss_05.indd 1 15/09/2015 08:46:30 CONTENTS SECTION PAGE 1.0 INTRODUCTION 3 2.0 TECHNICAL SPECIFICATIONS 4 3.0 INSTALLATION 6 4.0 COMMISSIONING

More information

GAS STATIC OVEN RANGES

GAS STATIC OVEN RANGES INSTALLATION AND OPERATION MANUAL GAS STATIC OVEN RANGES G504 G528 232428-3 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited E.Mail: vsales@moffat.com.au

More information

Gas Range Static Oven

Gas Range Static Oven Installation and Operation Manual Gas Range Static Oven Series RN8910G RNL8910G RNB8910G RNLB8910G Date Purchased Serial Number Dealer Service Provider 1 For use in GB & IE 232779-8 MANUFACTURED BY Moffat

More information

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539 User and Installation Instructions Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539 Dear Customer Thank you for purchasing this Lincat product. With correct use and careful maintenance

More information

BLACK KNIGHT 2 - Classic Collection

BLACK KNIGHT 2 - Classic Collection BLACK KNIGHT 2 - Classic Collection Installation & Servicing Instructions (GC No. 32 170 16) IMPORTANT - THIS FIRE DOES NOT NORMALLY REQUIRE ADDITIONAL VENTILATION INTO THE ROOM IN WHICH IT IS INSTALLED

More information

Gas Fire Patio Heater Lhotse-817

Gas Fire Patio Heater Lhotse-817 Gas Fire Patio Heater Lhotse-817 Instruction Manual Please read the manual BEFORE you unpack or install the fire TABLE OF CONTENTS Warning 3 Getting Started 4 What s Included 5 Assembly Procedures 6 Product

More information

MODEL 466 Radiant / Convector Gas Fire Black Beauty

MODEL 466 Radiant / Convector Gas Fire Black Beauty I N S T A L L E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty Please keep in a safe place for future reference 600A734/02 Please leave this Installer Guide with the user This appliance

More information