R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

Size: px
Start display at page:

Download "R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas"

Transcription

1 DATA SHEET: TDS101.4F kW R-SERIES YEAR ROUND MAXIMUM CONDENSING BOILER burning diesel oil, kerosene, natural gas or liquid petroleum gas 92% to 99.5% GCV efficiencies throughout the year Modulating, High/Low and On/Off Burners Pre-mix burners on Natural Gas with NOx < 30mg/kWHr Balanced or conventional flues up to 50 metres or more Built-in shunt pump and header 3 BARS standard maximum working pressure 4, 5, 6 or 7 BARS (available to order) 95 C maximum working temperature 90% and above A A 86% - 90% B 82% - 86% C 78% - 82% D 74% - 78% E 70% - 74% F Below 70% G Demountable for access through most openings Easy maintenance of boiler, burner and controls

2 ABOUT THE ATLANTIC R-SERIES BOILER The ATLANTIC R-Series year-round maximum condensing boiler has two distinct heat exchangers, the first of developed quality steel design and the second of high grade plastic design. The flue gases leave the first heat exchanger at temperatures below 90 C, and are then extracted from the second condensing heat exchanger at temperatures always below 50 C. The introduction of combustion air through the condensing exchanger lowers the flue gas temperature below dew-point, hence there is no need for return water temperature to be low. BURNER MAIN HEAT EXCHANGER HEATING FLOW & RETURN FRESH AIR The boiler will condense to it's maximum efficiency even at 82 C flow & 71 C return. For combustion air, at inlet temperatures below 30 C, efficiencies always exceed 92%. These conditions apply throughout the year in the UK. CONDENSING EXCHANGER FLUE GASES TREATED CONDENSATE The lower part of the condensing exchanger has a condensate neutralising section built in, eliminating the need for separate equipment in the future. The ATLANTIC R Series boiler pipework requirements are as straight forward as a conventional boiler or a high efficiency boiler. No special circuits are required to create condensing. Cross section of main heat exchanger Front view of main heat exchanger (purple) and of condensing exchanger frame (yellow) IN-BUILT FEATURES Constant temperature requirements are achieved with boiler controller, shunt pump, 4-port valve and flow sensor. Minimum flow and minimum temperature requirements are achieved with boiler controller, pump, 4-port valve and sensor. Variable temperature requirements are achieved with boiler controller, shunt pump, 4-port valve, outside sensor and flow sensor. All the above systems can be provided by the boiler system. Alternatively, the ATLANTIC R Series boiler(s) can be enabled by a BMS system and also can provide alarm signals to a BMS system. The boiler(s) will continue their own in-house operational control ensuring correct combustion and hydraulic function. As a modulating burner option, the boiler controller system can be modified on a 0-5 volt and 0-10 volt band to give variable heat output.

3 PERFORMANCE, DIMENSIONS & CONNECTIONS PERFORMANCE DIMENSIONS CONNECTIONS Model Maximum Output kw Standard Minimum Output kw Full load efficiency Ambient air 22ºC Oil % gcv Gas % gcv Fuel used Oil ltrs/hr Gas m³/hr Exit Flue gases@30ºc Oil m³/hr Gas m³/hr Dry weight kg Water contents ltrs Min water pressure BARS Standard water pressure BARS Max (on order) BARS Model Height mm Width mm Depth mm Height-demountable mm Width-demountable mm Depth-demountable mm Access front mm Access one side mm Access other side mm Access rear mm Access top mm Model Fresh air inlet mm Warm air burner inlet mm Fresh gas outlet mm Heating flow mm Heating return mm Hot water primaries mm Condensate mm SPECIFICATION The boiler body is made of 3mm thick quality steel with a water-cooled combustion chamber. The burner fires horizontally through the combustion chamber and makes a series of passes through a horizontal heat exchanger. The steel boiler is externally covered with an 80mm layer of rock wool thermal insulation. Access to the heat exchanger is through a panel at the front of the boiler secured by four bolts. The condensing exchanger is made of polypropylene and contains a series of smooth polypropylene heat exchanger tubes. The bottom of the condensing exchanger has a section containing limestone granules to neutralise the condensate. The boiler has a pre-wired control panel incorporating an isolator switch with indicator lamps, modulating, high/low or on/off burner control, water flow sensor with indicator lamps, a safety limit thermostat, hours run indicator, flue gas thermometer and a weather-controlled programme. The boiler assembly includes a 4 way valve, a shunt pump, both pre-wired and operated by the control panel, and a shunt pipe arrangement with connections for a restricted constant temperature circuit. The pressurised B100 or gas burner has; aluminium body, motorised fan air supply, oil or gas valve with controlled rate of opening, ignition transformer, air/b100 or air/gas mixing, combustion head, differential pressure switch, control box with ionisation flame protection, balanced flue pressure switch controls. Burners are available with pre-mix, modulating, high/low and on/off operation depending on fuel type and model size. The flue gas fan(s) in each boiler assembly contain - aerodynamic polypropylene housing, vibration free mountings, minimum pressure loss inlet & outlet, totally enclosed synchronous motor, maintenance free, dust & water proof bearings, infinitely adjustable fan motor speed regulator. The number of fans depends on the boiler model. From the model R22-15 to the model R22-90 the fan is mounted within the boiler casing. From model R upwards, the multi-fan assembly is mounted to the rear of the boiler.

4 TYPICAL VIEWS OF THE R NG.M PRE-MIX NATURAL GAS MODULATING R22 SERIES BOILER ABOVE: Front view of boiler showing modulating pre-mix burner and pre-warmed combustion air tube serving the burner ABOVE: Rear view of boiler showing add-on flue gas fan assembly LEFT: Side view of boiler with engineer checking burner settings RIGHT: Rear view of boiler showing shunt pump and 4-way valve assembly together with safety control panels and safety relief valve APPLICATIONS Airport terminals Ambulance and Fire Stations Art Galleries and Museums Banks and Shops Boarding Schools Business Centres Children s/nursing Homes Churches and Cathedrals Colleges and Universities Country Houses Day Nurseries Department Stores Factories Greenhouses and Botanical Gardens Halls of Residence Hospitals Hotels and Motels Housing Developments Leisure Centres Libraries Listed Buildings Motorway Services Office Buildings Police Stations Postal Sorting Offices Prisons Residential Hostels Residential Nursing Homes Shopping Malls Sports Clubs Swimming Pools Theatres Warehouses

5 ISOMETRIC DRAWING 4 way valve, variable temperature circuit Main heat exchanger Temperature circuit, flow and return Boiler shunt pump Condensing exchanger Fan assembly Factory Quarter Development, Acton 2 - R22-500kW dual-fuel B100 biodiesel and natural gas condensing boilers leading 4 - NA-R 930kW natural gas high efficiency boilers Clarence House, St James Palace 2 - R22-150kW natural gas condensing boilers with facility to switch to B100 bio-diesel St Andrews Hospital, Northampton 3 - R22-500kW digital modulating natural gas condensing boilers High Peak Housing, Derbyshire 2 - R22-150kW natural gas condensing boilers Glencanisp Lodge, Scotland 1 - R22-90kW kerosene condensing boiler

6 PIPEWORK ARRANGEMENTS Each boiler has its own header with in-built 4-port valve and shunt pump. This guarantees minimum water flow and temperature control. Single and group boilers can use a balancing & sedimentation vessel or a low velocity header as a neutral heat outlet. Any number of circuits, in order of priority, can then be served adequately from the boiler(s) TYPICAL ONE BOILER ARRANGEMENT One R22 boiler serves domestic hot water (priority) and weather compensated radiators. The fast-response indirect cylinder always needs to receive primary hot water within 1 or 2 minutes of demand so it receives priority from the balancing vessel or header. The radiators have a response time of about 20 minutes so they take primary heat as a second function. Consequently the indirect cylinder is served first from the balancing vessel. BALANCING VESSEL Domestic Hot Water Priority Weather compensated space heating ACFE Auto top up unit and fast fill bypass kit DHW MULTIPLE BOILER ARRANGEMENT This might be a typical medical centre situation where duty and standby boiler plant serves sanitary hot water, air conditioning and underfloor space heating. The ultra-fast response plate heat exchangers need primary heating within a few seconds, the air conditioning (in mid-winter) needs primary heating within a few minutes, whereas the underfloor space heating has a much longer response time. The plate heat exchangers are served first from the balancing vessel, the air conditioning second and the under-floor heating last. PHE DHW PHE Duplex Domestic Hot Water Priority BALANCING VESSEL Constant Temperature Variable Temperature Weather Compensated Space Heating ACFE Auto top up unit and fast fill bypass kit

7 CONDENSING FLUE ARRANGEMENT The ATLANTIC R Series boilers can have either conventional or balanced flues for diesel oil, kerosene, natural gas or LPG. The boiler flue requirements are economic often cutting the costs of material and labour when compared to other boilers. As the flue gas exit temperature is always low, the volume of gases is always greatly reduced throughout the year. Flexible tube Jubilee tube Socket Viton Seal Drain FLEXIBLE CONNECTOR Boiler 135 connector 90 connector Boiler straight connector Drain connector Use of brick chimney stack to form vertical balanced flue Single boiler balanced flue for flat or pitched roof Flue gases Flue gas effluent Fresh air 360 inlet Fresh air FLAT OR PITCHED ROOF Warmed air inlet to boiler Chilham Castle, Kent Flue gases from boiler In addition, the ATLANTIC R Series boilers have variable speed flue gas extract fans which permit extensive vertical and horizontal flue ducts in carefully chosen TECHNAFLON condensing flues. The flues are graded to the boiler(s) to allow the condensate to drain to the tank in the base of each boiler. The condensate is then treated using limestone marbles before flowing out to a normal drain. TECHNAFLON condensing flues are precision-made from polyvinylidene fluoride (PVDF) which is extremely corrosion-resistant, hard wearing and not effected by ultra-violet radiation. The flues are installed without insulation. The flue gases cool rapidly, releasing the heat to the building and increasing the plant efficiency.

8 BALANCING AND SEDIMENTATION VESSEL The balancing vessel is located close to the boilers, with its feet placed on a base to allow the boiler flows and returns to normally vent to the vessel. One full size cold feed pipe should be taken to the connection P on the vessel and fitted with a normally open ball valve, allowing unrestricted heating system expansion and contraction to take place along the pipe. The different flow pipes of separate heating circuits should be connected progressively down the header from the top flow 'A'. The returns should be connected similarly upwards from the bottom return 'I'. DHW priority flow and return circuits should be taken from and to the high level W tappings. When connections are complete and the system is ready for filling. Firstly everything should be isolated from the vessel. This includes the boilers (with their shunt pumps) connected to L (flow) and M (return) and the heating circuits - 'A' and 'I'. - which should be isolated from the vessel. The vessel air vent V and drain/sludge valve D should be closed. The different heating circuits should then be filled separately. As the circuits are progressively filled, they should be regularly sludged through the bottom of the vessel by opening the circuit valves and the drain and sludge valve until the BSV AND SV STANDARD DIMENSIONS Capacity Diameter 116kW 100mm 348 kw 150mm 696 kw 200mm 1740 kw 300mm 2900 kw 500mm water clears. This should be repeated for all the circuits. After filling all the circuits, the circuit pumps should be set running to check for further sedimentation arriving in the vessel. When this is clear, the boiler valves may be slowly opened and then the shunt pumps set running. BSV116 L M Balancing and Sedimentation Vessel P V W W D A I ABOUT ATLANTIC ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within two years had supplied the first commercial gas condensing boilers in the United Kingdom. For 30 years, ATLANTIC BOILERS has supplied both gas and oil condensing boilers to many Universities, Hotels, Hospitals, Medical and Social Care Buildings, Leisure Centres, Schools, Offices and Housing Developments plus many other types of buildings. ATLANTIC BOILERS also supplies condensing and highly efficient domestic hot water generation, based on stainless steel manufacture. Coupled with the supply, ATLANTIC BOILERS provides back-up commissioning, spares and servicing by way of a network of merchants throughout the United Kingdom. ATLANTIC BOILERS HIGH EFFICIENCY CONDENSING BOILER-PLANT ADDRESS: ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR WEB: INFO@ATLANTICBOILERS.COM TEL: FAX: ATLANTIC boilerplant sales ACM ATLANTIC - commissioning and maintenance ATLANTIC spares

ELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr

ELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr 1kW to 980kW WATER HEATERS 445 to 7520ltrs/hr ELECTRIC BOILERS ELECTRIC DOMESTIC HOT WATER HEATERS ABOUT ATLANTIC ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within

More information

MULTI ELEC. Electric Boilers TECHNICAL MANUAL

MULTI ELEC. Electric Boilers TECHNICAL MANUAL MULTI ELEC Electric Boilers TECHNICAL MANUAL PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) 161 621 5960 Fax +44. (0) 161 621 5966 info@atlantic2000.co.uk www.atlanticboilers.com 2 CONTENTS DESCRIPTION....

More information

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0) User Manual PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) 161 621 5960 Fax +44. (0) 161 621 5966 info@atlantic2000.co.uk www.atlanticboilers.com 1 CONTENTS CONTROL STRATEGY GENERAL RULES.. P3 Variable temperature...

More information

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

MAX O GAZ. Condensing water heater TECHNICAL MANUAL MAX O GAZ Condensing water heater TECHNICAL MANUAL 2 CONTENTS THE COMPONENTS OF THE MAX O GAZ.. 1 4 BALANCED FLUE AND CONVENTIONAL FLUE MAX O GAZ FEATURES. 3 6 INSTALLATION OF THE MAX O GAZ... 5 8 STANDARD

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:

More information

Multi-Elec COMPACTE BOILER

Multi-Elec COMPACTE BOILER Multi-Elec COMPACTE BOILER TECHNICAL MANUAL 03/2013 CODE: 560956 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) FOR TECHNICAL HELP/ADVICE Call 0161 621 5960 or email info@atlanticboilers.com

More information

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency

More information

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder

More information

The iqe Boiler Range. Combination and System T Boilers.

The iqe Boiler Range. Combination and System T Boilers. The iqe Boiler Range Combination and System T Boilers www.iqe.co.uk iqe - Max Technology Max Efficiency iqe is a select group of partners that have come together to create a unique product range of highly

More information

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.

More information

FCX FUEL OIL CONDENSING BOILER RANGE

FCX FUEL OIL CONDENSING BOILER RANGE FCX FUEL OIL CONDENSING BOILER RANGE BOILERS FUEL OIL, CONDENSING CHIMNEY OR BALANCED FLUE HEATING ONLY DOMESTIC HOT WATER OPTIONS OUTPUT 22.3 kw or 30.5 kw Why choose a Geminox boiler? To benefit from

More information

EFG ENERGY OPTIMISING SYSTEMS

EFG ENERGY OPTIMISING SYSTEMS EFG ENERGY OPTIMISING SYSTEMS High-performance energy control systems for maximum performance from solar collectors and other renewable and non-renewable heat sources Maximum comfort, minimum energy costs

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

Series 1000 & Storage Water Heaters

Series 1000 & Storage Water Heaters Series 1000 & 2000 Storage Water Heaters 1000 Series Vented Water Heaters THE 1000 SERIES WATER HEATER IS SUPPLIED VIA A HEADER TANK AND IS SUITABLE FOR A WIDE RANGE OF COMMERCIAL AND INDUSTRIAL APPLICATIONS

More information

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler H o t Wa te r Syste m s Senator Electric Flow Boilers Making Life Simpler Electric Wet Central Heating The Range Senator electric flow boiler is designed to heat re-circulated water used in wet central

More information

Sirius WH. Working towards a cleaner future

Sirius WH. Working towards a cleaner future Sirius WH Wall Hung Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 110kW Modular Boiler Applications: up to 880kW Working towards a cleaner future heating specialists 1. Product Overview

More information

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25) ALKON CARGO ALKON CARGO model Max/min nominal output Heat input condensing Non-condensing η condensation at 30 part load 35 7,4 35,1 6,7 33,5 34,8 106,3 Efficiency class (directive 92/42) ALKON CARGO is

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW. Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to bar. Heatpack boilers to 2900kW. Whether your application is for single, multiple or space saving heatpack boilers, Hoval always

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw 90 kw Clyde Alkon 90 LP Gas Floor standing condensing boilers Natural Gas 90 kw Contents General information Dimensions and Data Installation requirements Boiler wiring diagram Hydraulic systems Page Fully

More information

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

FEATURES AND BENEFITS. Up to 109.8% part load efficiency IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

Link-Up. Solid Fuel Association Guide to Central Heating.

Link-Up. Solid Fuel Association Guide to Central Heating. Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers Ethos Range High Efficiency Domestic Boilers Combination Boilers Condensing Combination Boilers Condensing System Boilers From 1994, Mikrofill has been supplying high quality products to the commercial

More information

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers * 5 YEAR GUARANTEE Inovia High efficiency condensing combi and system boilers WALL HUNG BOILERS Inovia INOVIA HIGH EFFICIENCY BOILER RANGE The Inovia range is the latest in intelligent gas boiler technology

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Amptec. Electric flow boiler

Amptec. Electric flow boiler Amptec Electric flow boiler the nation s favourite for PLUMBING & HEATING SUPPLIES FREE SHIPPING on all orders over 100 to mainland UK FINANCE AVAILABLE spread the cost with low interest rates SECURE PAYMENTS

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

Assessment Schedule - TS.6

Assessment Schedule - TS.6 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Copper-Fin GAS-FIRED WATER HEATERS

Copper-Fin GAS-FIRED WATER HEATERS Copper-Fin GAS-FIRED Lochinvar Corporation has been designing, manufacturing and distributing water heating products in USA since 1919 and has built an enviable reputation for reliable, efficient and cost

More information

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar Hoval SR-plus heating boilers Outputs from 30 to 4000kW Working pressures to 8 bar ...built in the UK where high quality and reliability have been a way of life for generations. Hoval SR-plus Simplicity

More information

thermocompact High performance system boiler range

thermocompact High performance system boiler range thermocompact High performance system boiler range Built-in performance The expectations of today s system boiler have never been more demanding, which is why Vaillant s thermocompact range comes with

More information

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009 Installation, Operation and Maintenance Instructions Electric Flow Heater OM009 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk

More information

MULTIPLEX SELF RECUPERATIVE gas burner

MULTIPLEX SELF RECUPERATIVE gas burner Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and

More information

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 0, 6, 5, 4 kw CLASS IN EN 0/5 Innovation with meaning BioClass NG IN EN 0/5 CLASS DOMUSA has managed

More information

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame

More information

CP+ Gas & Oil Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed

More information

LBF RANGE BALANCED FLUED WATER HEATERS

LBF RANGE BALANCED FLUED WATER HEATERS LBF RANGE BALANCED FLUED WATER HEATERS WHY BALANCED FLUE? Lochinvar Corporation has been designing, manufacturing and distributing water heating products in USA since 1919 and has built an enviable reputation

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, 50-70 FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Thank you for purchasing a Danesmoor

More information

CAST IRON ATMOSPHERIC BOILERS

CAST IRON ATMOSPHERIC BOILERS CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron

More information

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS GAS 110 ECO WHAT S INSIDE 03 WELCOME TO REMEHA 03 INTRODUCING THE REMEHA GAS 110 ECO RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 11 DIMENSIONS

More information

S-AF Floor Standing Condensing Boiler kW

S-AF Floor Standing Condensing Boiler kW Clean Heating Naturally STREBEL MMERCIAL BOILERS S-AF Floor Standing Condensing 11-620 Why choose Strebel? S-AF Floor Standing Condensing Strebel Ltd has been supplying, installing and servicing coercial

More information

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi cxi sxi ranges product specifications Product Range Type Model 12 15 18 24 30 38 cxi Combi 24cxi cxi Combi 30cxi cxi Combi 38cxi sxi System 18sxi sxi System 30sxi ppearance esthetic Casing dimensions (h

More information

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters MADE IN ITALY THE EXPERT of stainless steel condensing heating systems ECO FRIENDLY wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters AISI 6Ti

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw MADE IN ITALY THE EXPERT of stainless steel condensing heating systems ECO FRIENDLY wallmounted boilers, water heaters and pool heaters from 15 kw to 140 kw floor standing boilers, water heaters and pool

More information

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters  T (0) Installation & Operating Manual ZM-130 16 32kW Universal Oil Heater OVERVIEW Dfdfdfdsfd Dfdfffdfdf Dfdfdf 4 1. Overheat thermostat 2. Combustion chamber lid 3. Oil feed line 4. Activation thermostat 5.

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

The Ultimate Solution for Electric Central Heating. Fusion. Comet

The Ultimate Solution for Electric Central Heating. Fusion. Comet The Ultimate Solution for Electric Central Heating Fusion Comet Our range of Electric Boilers provide complete peace of mind for reliability, performance and safety 2 The Fusion range of electric boilers

More information

INDEPENDENT COMBINATION & SYSTEM BOILERS.

INDEPENDENT COMBINATION & SYSTEM BOILERS. INDEPENDENT COMBINATION & SYSTEM BOILERS. RELIABLE IDEAL BOILERS EXCLUSIVELY AVAILABLE AT YOUR LOCAL INDEPENDENT MERCHANT. *7 YEAR WARRANTY UNTIL 31ST DEC 2016 ON INDEPENDENT+. 1 GREAT BOILERS FROM GREAT

More information

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE: USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE: 0870 428 0075 CONTENTS Page 2 - Unpacking Page 3 - Heating system preparation and

More information

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary... 5.5.1 General... 13 5.6 CD/30 (Oil Condensing Boiler Installation Assessment Form)... 15 5.6.1 General... 15 5.7 Technician Stationary... 18 5.7.1 CD/40 Energy Efficiency Checklist... 18 5.8 Work Notification

More information

GRANT. Euroflame Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

GRANT. Euroflame Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS Part No. IRL 013 Rev. 01 May 2010 EFFICIENT HEATING SOLUTIONS GRANT Euroflame Condensing Oil Boilers USER, INSTALLATION and SERVICING INSTRUCTIONS Indoor/Utility and Boiler House Models with outputs up

More information

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation

More information

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE Item 1) TWO THERMAL OIL HEATERS OF 1200 kw EACH 1.1) THERMAL OIL HEATER BODY Brand PIROBLOC Model GFT-060/40/H2 Power 1200 kw Delta Temperature 40 ºC Execution Horizontal Designed and built According AD-2000

More information

Heating & cooling Australia since 1965

Heating & cooling Australia since 1965 www.aira.com.au Heating & cooling Australia since 1965 www.aira.com.au AIRA has been a leading Australian manufacturer and supplier of commercial and industrial products since 1965. AIRA supplies in standard

More information

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA INSTALLATION AND OPERATING INSTRUCTIONS KLIMA - 1 - CONTENTS 1.- PRESENTATION... 2 2.- LIST OF COMPONENTS... 3 3.- CONTROL ELEMENTS... 4 4.- INSTALLATION INSTRUCTIONS... 5 4.1 LOCATION... 5 4.2 FLUE...

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

Cast Iron Boilers. G Series ( kW)

Cast Iron Boilers. G Series ( kW) Cast Iron Boilers G Series (320-1017kW) Mikrotherm G Series Cast Iron Boilers The Mikrotherm G Series of cast iron sectional boilers offer all the advantages of cast iron durability and longevity coupled

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw atural gas Class D oil Dual Fuel 350 kw to 500 kw Clyde CK40 Cast Iron Boiler Contents Page General information Dimensions 3 Technical data 3 Installation requirements 4 & 5 Boiler control panel 6 Wiring

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data INSPIRED EF F ICIENCY CONDENSING BOILERS ETHOS 350 & 550 FLO O R ST AN D I N G CO N DE N SI N G BOI L E R S T ECHN I CAL DO CUME N TA T I O N I SSUE 0 3 /1 6 R e v. 0 1 TABLE OF CONTENTS 1. 2. 3. 4. 5.

More information

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW Hamworthy Melbury HE High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners Outputs 530 to 10000 Melbury HE High Efficiency Steel Shell Boilers Gas, Oil, Biofuel or Dual

More information

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package OM014 Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package The operating and maintenance instructions contained within this package are for PlantPac packaged

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL BRILEY CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER 60 140 kw 0604.2 Beeston Briley cast-iron premix gas-fired boiler 60-140kW Contents 1 Boiler specifications Page 3 2 Appliance general dimensions

More information

GIALIX. An adjustable power to match your needs for more economies! Wall-mounted electric boiler 2 to 196 kw. F RENCH Manufacturer.

GIALIX. An adjustable power to match your needs for more economies! Wall-mounted electric boiler 2 to 196 kw. F RENCH Manufacturer. GIALIX Since 1892 Wall-mounted electric boiler 2 to 196 kw RT 2012 D An adjustable power to match your needs for more economies! THE ONLY BOILER IN THE WORLD WITH A 20 YEARS GUARANTEED CAST IRON heating

More information

the electric heating company ELECTRIC BOILER HANDBOOK

the electric heating company ELECTRIC BOILER HANDBOOK the electric heating company ELECTRIC BOILER HANDBOOK About Us Innovative heating and hot water specialists, The Electric Heating Company, have developed their product portfolio to accommodate almost any

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range Install warmth, efficiency & peace of mind Contents Solo HE A 1 Megaflo System HE A IE 4 Bermuda BBU HE 7 Flue Options

More information

The Greenstar CDi gas-fired condensing combi boiler series. Technical and specification information

The Greenstar CDi gas-fired condensing combi boiler series. Technical and specification information The Greenstar CDi gas-fired condensing combi boiler series Technical and specification information CORGI Award winner 2005, 2006 & 2007 Worcester, Bosch Group headquarters Worcester and you. Making a difference.

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28 The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.

More information

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options A BOILER WITHOUT A FLAME HIU Single PHE options heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment

More information

ecotec plus New high efficiency condensing combination and system boiler ranges

ecotec plus New high efficiency condensing combination and system boiler ranges ecotec plus New high efficiency condensing combination and system boiler ranges Simply high performance With condensing boilers becoming ever more widely used the need for high performance products that

More information

GRANT VORTEX Condensing Oil Boiler range

GRANT VORTEX Condensing Oil Boiler range Part No. DOC 37 Rev. 13 October 2006 USER, INSTALLATION and SERVICING INSTRUCTIONS GRANT VORTEX Condensing Oil Boiler range Kitchen, Kitchen System, Utility and Utility System Models with outputs up to

More information

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Euron Compact Wall Mounted as Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Compact, Efficient & Easy to Install & Maintain The Euron range of wall mounted gas fired condensing boilers

More information

GB24 & GB30. User Manual

GB24 & GB30. User Manual GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum

More information

STREBEL S-CB + Cascade Kits

STREBEL S-CB + Cascade Kits STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave

More information

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW. boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 00 to 0kW. DHW output to,00 litres per hour. Where quality and reliability cannot be compromised, select the

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE

More information

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW Ultramax R600 High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW Delivering excellence with every feature The Ultramax R600 series of boilers is packed with features

More information

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES 24-28Si II SERIES G.C. NUMBERS APPLIANCE NATURAL GAS L.P.G. 24Si II 47 311 65 47 311 66 28Si II 47 311 67 47 311 68 USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD CONTENTS Page No.

More information