1 11 CHAPTER 2 LITERATURE REVIEW 2.1 INTRODUCTION For better human comfort, cooling of living or work environment is vital in tropical climates. Researches carried out till date in evaporative air cooling process focus mainly on reducing the dry bulb temperature of the incoming air. Theoretical efficiency of 100% can be realized when dry bulb temperature of the room is equal to wet bulb temperature of the outside ambient air; Evaporative cooling efficiency is defined as the ratio between drop in dry bulb temperature across the cooler and the difference between inlet DBT and inlet WBT. Many researchers have worked on improving evaporative cooling efficiency to the maximum possible extent. The present chapter reviews various studies carried out related to the evaporative air cooling recently and the past. The cooling efficiency of the evaporative cooling system is found to be increased by imparting the following three methodologies in the system, viz., (i) Introduction of suitable components for effective evaporation; (ii) Combining direct and indirect cooling systems; and (iii) Utilization of different pad materials with different thicknesses. Section 2.2 deals with the studies related to the improvement in evaporative cooling efficiency by the appropriate system modification in the conventional evaporative air cooling system. Studies on indirect / direct (two stage) evaporative coolers are presented in Section 2.3. Effects of various pad materials are discussed in Section 2.4. Studies conducted to evaluate the

2 12 influence of various process parameters on the cooling efficiency are presented in the section 2.5. The studies related to the development of mathematical models and its validation for analyzing the performance of the cooler are presented in Section 2.6. The chapter ends with foremost conclusions arrived out of this review and objectives of the present research work. 2.2 EVAPORATION RATE ENHANCEMENT STUDIES Giabaklou and Ballinger (1996) have attempted to study the effectiveness of a passive evaporative cooling system employing natural ventilation. The front faces of a building are provided with water guide filaments, where in water flows from the top to bottom by gravity. The incoming air gets cooled and goes inside the building. Such a system is found to reduce the temperature of incoming air by 9.9 ºC, averaged over a day. Giabaklou (2003) has extended the study the using Fanger PMV (Predicted Mean Vote) methodology. It shows that such a system can improve PMV significantly when the number of air changes per hour is higher. Kant and Mullick (2003) have studied on thermal comfort in a room with exposed roof using evaporative cooling system. Hourly values of temperature and humidity are computed and compared with the values that are obtained during unexposed condition. The levels of thermal sensation, which could be obtained with a direct evaporative cooler, are computed. Kittas et al (2003) have investigated the temperature and humidity gradients during summer in a greenhouse equipped with a ventilated cooling-pad system and half shade plastic roof. The cooling performance up to 80 % is reported. The temperature of the greenhouse is lowered by 10 ºC than the outside air.

3 13 Taufiq et al (2007) have conducted an energy analysis of evaporative cooling for reducing energy use in a building. A correlation has been developed between relative humidity and energy efficiency, and between ambient temperature and energy efficiency. The results of the study revealed that when relative humidity is increased, energy use also increases. The study concluded that the evaporative cooling is a feasible technology that can reduce mechanical cooling and energy requirement. Shukla et al (2008) have done an experimental study in a cascade green house with inner thermal curtain. About 5-8 ºC reduction in the temperature of greenhouse is reported during hot summer in Delhi. Energy saving aspects are attempted by Al-Azzawi and Almuhtadi (2009) using of newly designed automated solar powered evaporative cooler. Naticchia et al (2010) have used a new novel technique, water-evaporative wall, which reduces the conduction heat gain across the walls. The experiments have shown to reduce the summer overall heat load considerably. He and Hoyano (2010) have studied the cooling effects of passive evaporative cooling wall constructed of porous ceramic materials. Experimental results showed that the cooling efficiency reached a maximum of 0.7 during sunny daytime periods. A higher cooling efficiency is obtained under windy conditions where wind at a speed of 1-3 m/s is continuously blowing. Heidarinejad et al (2010) have investigated a hybrid system of nocturnal radiative cooling and direct evaporative cooling and up to 13.5 ºC reduction in indoor temperature is reported. 2.3 STUDIES ON INDIRECT / DIRECT EVAPORATIVE COOLING SYSTEMS Datta et al (1987) have experimentally studied an 8.5 ton indirect-direct evaporative cooling system and reported that such a system

4 14 provides a relief cooling rather than comfort cooling. The room could be maintained at 4-5 ºC above the inlet wet bulb temperature using such a cooler. A facility of using indirect-direct evaporative cooling for residential use in arid regions of Israel is attempted by Navon and Arkin (1994). Such a system is shown to provide higher level of thermal comfort where external humidity is around 80 %. Singh et al (1991) have attempted to save the electricity used in the circulation pump. The existing evaporative cooler is retrofitted with an over head tank and a limit switch, which switches on the circulation pump when tank water level is low and stops when tank water level is full. By such process 75 % savings in electricity are reported for the same system performance levels. Sodha et al (1995) have evolved a rule thumb for direct evaporative cooler for various floor areas to be cooled for hot, dry and composite climates. El-Dessouky et al (2000) have developed a membrane air dryer and coupled with conventional direct / indirect evaporative cooler. As the membrane drier, removes the moisture from the incoming air, the air can be cooled to lower temperature by the subsequent evaporative cooler. Using such a system, reasonable cooling has been obtained. When such system is combined with Mechanical Vapour Compression system to achieve to perfect thermal conditions, about 50 % savings in electricity are obtained. Gomez et al (2005) have developed a ceramic evaporative cooling system which acts as a semi-indirect cooler. The water cooled in a cooling tower is passed through the annulus passage of the ceramic tube. The out side air is passed through the central region. Chilled water evaporates by seeping through pores. Such a system permits the recirculation of indoor air, which is not possible in the conventional evaporative cooling system. Use of such

5 15 system is experimentally demonstrated and 5-12 ºC drop in temperatures is obtained under various conditions. Jain (2007) has developed and tested a two-stage evaporative cooler. Such a cooler could provide necessary comfort even though outside humidity is higher. The two-stage cooler is found to provide 20 % better cooling when compared to single stage cooler. A novel dew point evaporative cooling system for sensible cooling of ventilation air has been developed by Riangvilaikul and Kumar (2009) and tested experimentally. Wet bulb effectiveness of % and the dew point effectiveness % are reported. Heidarinejad et al (2010) have tested a ground assisted hybrid evaporative cooling system in Tehran. The ground coupled circuit provides necessary pre-cooling effects. Simulation studies have shown that such a hybrid system can provide cooling effectiveness of %. 2.4 STUDIES ON THE EFFECT OF PAD MATERIAL In case of cabinet type evaporative coolers, the type of pad material used plays a major role. Natural and man-made materials are tested by various investigators. Table 4.2 present the details. With the materials with more wick-like characteristics, the water spreads easily which offers more surface area; hence, better evaporation rate is possible. With commercial pads, about 50 % evaporation efficiencies are reported. Almost all natural materials (except Date - palm fiber) offer equivalent or better performances. PVC sponge and CELdek offer higher evaporative efficiencies of around 80 %.

6 16 Table 2.1 Studies related to the effect of cooling pad material S.No. Author(s) Pad materials tested 1 Taha et al (1994) Charcoal granules C 2 3 Liao and Chiu (2002) Al-Sulaiman (2002) Coarse fabric PVC sponge Fine fabric PVC sponge Date palm fiber 39 % Temperature drop or Evaporative cooling efficiency reported 82 to 85 % 77 to 92 % Jute 62 %, Luffa 55 % Commercial pad 50 % 4 Anyanwu (2004) Porous C Gunhan et al (2007) Darwesh et al (2009) Ahmed et al (2010) Fine pumice stones 93 % CELdek 82 % Volcanic tuff 81 % Coarse pumice stones 76 % Greenhouse shading net 51 % Rice straw C, 77 % Palm leaf fibers C, 88 % CELdek C, 82 % Straw C, 79 % Sliced wood 9.53 C, 86 % 2.5 PERFORMANCE STUDIES ON EVAPORATIVE AIR COOLERS Performance of evaporative air coolers depends upon the outside air DBT and WBT, and the internal arrangement of the cooler which decides the rate of evaporation of water. The evaporation rate depends on air velocity

7 17 across the pad, frontal area of the pad, thickness of pad, water circulation rate and the flow arrangements Studies Related to Direct Evaporative Coolers (DEC) Dai and Sumathy (2002) have investigated a cross-flow direct evaporative cooler, in which the wet durable honeycomb paper is used as the packing material. A mathematical model is developed that include the governing equations of liquid film and gas phases as well as the interface conditions. The interface temperature of falling film is also predicted. The variation of temperature, humidity ratio in the flowing channel, effect of system size and effect of operation parameters as inlet temperature, humidity of inlet air and temperature of feed water are studied. The liquid gas interface temperature is predicted and the evaporative cooling process of falling film is analyzed quantitatively. The optimum length of air channel is also found. Elfatih et al (2003) have investigated the performance of porous ceramic evaporators for building cooling application. Low, medium, high porosity ceramics are tested with direct evaporative cooling system. High porosity ceramic accounted better performance, even when supply water flow rate is increased. There is a drop in dry bulb temperature and increase in relative humidity which are found to be 6-8 K and 30 % respectively. Maximum cooling recorded is about 224 W/m 2. Qureshi and Zubair (2005) have studied the impact of fouling on performance of evaporative coolers and condensers. The result revealed that the fouling of tubes reduces the performance. The maximum decrease in effectiveness due to fouling is found to be 55 % and 78 % for the evaporative coolers and condensers respectively. Dagtekin et al (2009) have studied the performance characteristics of pad evaporative cooling system in a broiler house in a Mediterranean

8 18 climate. There are 5 pads each m in size which are used for experimentation. The cooling system has six exhaust fans with maximum of 42,000 m 3 /h. The average evaporative cooling efficiency and temperature drop are found to be 70 % and 7.3 C. Hasan et al (2009) have studied the efficiency of fan-pad cooling system in green house by building up of internal greenhouse temperature map. The results reveal that the drops in temperatures are found to be C. Considerable differences are recorded between the temperatures in center of the pad and in front of the fans (13 C at right in front, 8 C at middle of the pad and 7 C in front of the fan). Workneh et al (2009) have investigated the effectiveness of forced ventilation evaporative cooling during storage of tomatoes and storability of pre harvest treated tomatoes using evaporative cooling methods. The average dry bulb temperature of ambient air and inside the evaporative cooling are observed as 32 C and 20.5 C respectively. An average temperature drop is found to be 11.5 C. The average relative humidity of ambient air and inside the evaporative cooling are recorded as 40 % and 83.9 % respectively. The average difference between the inside and outside relative humidity during the test is found to be 43.9 %. Tilahun (2010) has investigated the feasibility and economic evaluation of low-cost evaporative cooling system in a fruit and vegetables storage. The evaporative air cooler is able to decrease the air temperature from 36 C to 16.4 C and increase the relative humidity increased from 25.4 % to 91.1 %. 10 cm thickness cooling pad is used and the cooling efficiency obtained ranged between 55 % and 84 %. The power consumption recorded is 1.13 kwh for a fixed air flow rate of 4.3 kg/s. The energy efficiency ratio is found to be 26.3 for mentioned air flow rate. Wong and Chong (2010) have investigated the performance of misting fan in hot and humid climate. Experiments are conducted to evaluate

9 19 the thermal conditions and thermal sensations resulted from the misting fans. The results from the experimental procedure showed that the misting fan is able to effectively reduce the dry-bulb temperature by approximately C. The reduction in temperature comes at the expense of higher relative humidity which results in consistently greater biological (bacterial and fungal) pollutants; being enumerated from samples collected under the misting fan system. In some samples, the bacteria count was very much greater than the samples collected under the non-misting fan, illustrating the potential for a substantial increase in biological pollutants due to the generation of mists. Khandelwal et al (2010) have studied on the energy saving in a building using regenerative evaporative cooling. The result revealed that regenerative evaporative cooling system indicated significant potential for energy savings up to %, where as simple evaporative cooling system provided %. The indoor temperature obtained are between 22 C and 26 C. El-Awad (2010) has studied the feasibility of solar assisted winter air conditioning system using evaporative coolers. The evaporative air cooler obtains the heat through from solar energy for preheating the water supply. A theoretical model is developed for a room of m 3 volume. Typical power consumption is found to be 0.1 kw. It is estimated that, for air conditioning a 500 cfm air flow rate for a minimum of four hours operation, a 150 LPD solar heater is needed and for that of eight hours 250 LPD solar heater is needed. Studies have been carried out to study the influence of various geometric and operational parameters on the performance of cabinet type Direct Evaporative Cooler (DEC). Table 2.2 provides the details of studies on DEC and the related outcomes.

10 20 Table 2.2 Studies on effect of various parameters on DEC performance S. No Author(s) 1 Thepa et al (1999) 2 Kant et al (2001) 4 Lertsatitthanakorn et al (2006) Parameter studied Parameter Pad thickness Air velocity Range cm 1-5 m/s ACH 1-40 By pass of supplied air Mass flow rate of air % kg/s Outcome EC efficiency increased from 65 % to 85 % EC efficiency decreased from 95 % to 80 % When the pad thickness 50 cm. With increase in ACH, room condition moves up from Extended Comfort Zone. With increase in ACH, room condition moves down from Extended Comfort Zone. Efficiency increased from 66 % to 80 % Studies Related to Indirect Evaporative Coolers (IEC) Maheshwari et al (2001) have evaluated the energy saving potential of an indirect evaporative air cooler. Estimated cooling capacity of IEC is found to be 3.4 and 2.4 TR for interior and coastal areas respectively. Power requirements to achieve the above mentioned cooling capacity with air-conditioner for interior and coastal area are 4.93 and 3.85 kw, whereas 1.11 kw is needed for IEC. Chaktranonda and Doungsong (2010) have evaluated the energy savings in a split-type air conditioner with evaporative cooling system experimentally. The results revealed that ambient temperature of air had been much influenced by power consumption of compressor and COP R. When the temperature is raised by 1 C, electrical power consumption is increased by

11 21 around 4 %. Due to high contact surface between water and air-stream, the evaporative cooling system can decrease the power consumption by around 15 %, and can increase COP R up to 45 %. Table 2.3 provides the details of studies on effect of various parameters on the performance of IEC and the related outcomes. Table 2.3 Studies on effect of various parameters on IEC perfromance S. No Author(s) Parameter studied Parameter Range Outcome Velocity of primary air m/s Evaporative cooling effectiveness decreased from 0.93 to Guo and Zhao (1998) Velocity of secondary air Channel width m/s m Evaporative cooling effectiveness increased from 0.7 to 0.98 Evaporative cooling effectiveness decreased from 0.99 to 0.6 Plate wettability % Evaporative cooling effectiveness increased from 0.3 to Zhao et al (2008) Channel height 2.0 mm to 10 mm Dew point and wet bulb effectiveness decreased on increasing the channel height. At the channel height of 10 mm, the dew point and wetbulb effectiveness are 0.2 and 0.85 respectively. 3 Johnson et al (2003) Number of fiber arrays 20 to 160 Approximately 58 fiber arrays are needed to achieve 80 % efficiency Studies Related to Two Stage Evaporative Cooler El-Dessouky et al (2004) have carried out the performance analysis of two stage evaporative coolers. The system is operated as a function of the

12 22 packaging thickness and water flow rate of the DEC unit. The efficiency of IEC and DEC units when operated individually where found to be % and 63-93% respectively, whereas the efficiency of two stage IEC/DEC varied over a range of %. Heidarinejad et al (2009) have investigated the cooling performance of two stage indirect (IEC) / direct evaporative cooling (DEC) experimentally under various simulated climatic conditions. The cooling effectiveness of IEC in the range of % and that of IEC /DEC of % are reported under varying climatic conditions. Such system is found to be better for the hot and humid Iranian climates. El-Dessouky et al (1996) have studied the effect of various parameters on the performance of two stage evaporative cooler. The details are presented in Table 2.4. Table 2.4 Details of the study of El-Dessouky et al (1996) S. No Parameter studied Parameter Range 1 Packing type Packing thickness Mass flux of water Mass flow rate of water Structured Sheathy leaf Natural fiber mm kg/m 2 s kg/s Evaporative Cooling Effectiveness Evaporative cooling effectiveness 0.9 when the water flow rate is 0.03 kg/s Evaporative cooling effectiveness 0.8 when the water flow rate is 0.03 kg/s Evaporative cooling effectiveness 0.75 when the water flow rate is 0.03 kg/s Evaporative cooling effectiveness increased from 0.72 to 0.9, with structured packing Evaporative cooling effectiveness decreased from 0.85 to 0.74, with structured packing Evaporative cooling effectiveness increased from 0.85 to 0.9, with structured packing

13 STUDIES ON MODELING OF EVAPORATIVE COOLING SYSTEMS A mathematical model is the mathematical representation of a process, device or concept; it uses a number of variables to represent inputs and internal states, and sets of equations and inequalities to describe their interaction. Mathematical models developed for evaporative cooling system are used to predict the system behaviors like cooling efficiency, temperature drop, optimum air velocity for various inlet conditions. Landsberg et al (1979) developed a mathematical model to estimate the average air temperature inside the glasshouse, subjected to any specified radiant energy load, outside temperature and humidity. Kimmel et al (1991) developed a theoretical model of an evaporative cooling in a wetted hide; simulations have showed that the evaporative effectiveness and effective wettedness depend on the parameters like temperature, humidity, and air velocity and on intrinsic local properties such as water content and distribution within the hide. Thomson et al (1994) have developed a mathematical model using logarithmic approximation for estimating the performance of natural draft evaporative coolers. Abdel-Wahab (1994) have developed a mathematical model to estimate the water evaporation rate, air flow rate and cooling effect in an evaporative cooling system for a farm structure. Singh et al (1997) have developed a mathematical model to evaluate the relative thermal performance of a building coupled with an indirect and direct evaporative cooler. Zalewski and Gryglaszewski (1997) have developed a mathematical model of heat and mass transfer processes in evaporative fluid coolers. The model consisted of four ordinary differential equations with necessary boundary conditions and some associated algebraic equations. Alonso et al (1998) developed a mathematical model to predict the heat and mass transfer of an indirect evaporative cooler, the model is also be

14 24 used for energy analysis and system optimization. Halasz (1998) developed a general non dimensional mathematical model used for all types of evaporative cooling devices, for each device a unique rating procedure is established, irrespective of flow direction of the fluid involved. Zalewski et al (2000) have developed an algorithm for the optimization of evaporative fluid coolers incorporating the heat and mass transfer, operating costs and production costs of heat exchanger. Sweetland and Lienhard (2000) have developed a mathematical model using a Karman-Pohlhausen treatment of the velocity and thermal boundary layers accounting the evaporation of an entrained water spray and investigated the effect of the water sprays commonly used to cool freshly drawn glass fibers. In general, a reasonably good matching between the model and experimental data are reported in these studies. Al-Nimr et al (2002) have proposed a novel summer airconditioning system incorporating adiabatic dehumification using moisture absorbent and developed a mathematical model to predict the improvement in the performance. Dai et al (2002) investigated a cross-flow direct evaporative cooler, in which the wet durable honeycomb paper constitutes as the packing material; a mathematical model is developed that include the governing equations of liquid film and gas phases as well as the interface conditions. Shammiri (2002) have developed a correlation for measuring the rate of evaporation of water as the function of salinity of water. Kittas et al (2003) have predicted the temperature gradient in a partially shaded large green house equipped with evaporative cooling pads, a simple climate model is developed incorporating the effect of ventilation rate, roof shading and crop transpiration. Fisenko et al (2004) have developed a new mathematical model to predict the performance of mechanical draft cooling tower. Riffat and Zhu (2004) have developed a mathematical model of indirect evaporative air cooler which utilizes a porous ceramic and heat pipe; the mathematical model analyzed the effect of humidity and air velocity of passages. Fuchs et al

15 25 (2006) have developed a procedure to evaluate latent heat cooling by means of crop transpiration and free water evaporation in a wet pad and fan system. Beshkani and Hosseini (2006) have developed a mathematical model of a rigid media evaporative air cooler, equipped with corrugated papers as a wetted medium; saturation efficiency and pressure drop were evolved as a function of air velocity and depth of the media. Hettiarachchi et al (2007) investigated the longitudinal heat conduction in the exchanger wall of a compact plate cross flow indirect evaporative air cooler using NTU (Number of transfer units) method and block iterative numerical method. Wang et al (2008) have developed a fuzzy mathematical method and evaluated the suitability of an evaporative pad cooling system for poultry houses in China. Wu et al (2009a) conducted a theoretical analysis to evaluate the heat and mass transfer between air and water film in a direct evaporative cooler with wet durable honeycomb papers constituting the pad modules. Wu et al (2009b) investigated the heat and mass transfer in a direct evaporative cooler numerically; a simplified mathematical model is developed to describe the heat and moisture transfer between water and air in a direct evaporative cooler. In these studies, the predictions are reported to be in good agreement with the experimental data. 2.7 CONCLUSIONS FROM THE LITERATURE REVIEW major conclusions: From the review of literature presented above, the following are the i. With the ongoing energy crisis and pollutant emission constrains, use of evaporative air coolers are much advantages. ii. The difference between the outside air dry bulb temperature and the wet bulb temperature is the key factor which decides

16 26 the use of evaporative coolers. Larger the difference, usefulness of evaporative coolers is better. iii. iv. Evaporative cooling can reduce the incoming ambient air temperature to the room considerably. It is inexpensive, energy efficient and potentially attractive. Pre cooling of water could enhance a direct evaporative cooler that cools the air even below its inlet WBT. v. The reduction in temperature comes at the expense of higher relative humidity. It may be disadvantages in certain applications. vi. vii. Cabinet type evaporative cooler are most popular. The pad material, pad thickness, air velocity, water circulation rate, and flow arrangements are found to affect the performance of such evaporative coolers. Various attempts have been made to study the effect of various parameters on the evaporative cooler performance. The pad material, and pad thickness are found have the major role for a given air flow rate. viii. For the given conditions, there exists an optimum pad thickness balancing the evaporation rate and pressure drop across the pads. ix. Studies have shown that excessive water circulation does not contribute in improving the performance. Considerable energy savings are possible by optimizing the pump operations. x. Cabinet type coolers are sufficient for cooling of small air volumes. For large spaces, more cabinet coolers are employed.

17 27 xi. xii. For hot and humid climates, Indirect / Direct coolers are used. Such a coolers could provide better comfort with % of energy savings when compared to conventional Mechanical Vapour Compression Systems. Various other methods, like thermal curtain, providing water filament guides over external facet of the building, evaporative walls, are being attempted. xiii. Efforts have been made to model the performance of evaporative cooling systems and reasonable agreements between the predictions and experiments are reported. 2.8 CLOSING REMARKS The efficiency of evaporative air cooler mainly depends on outside dry bulb temperature, wet bulb temperature, inlet air velocity and the rate of water evaporation. The dry bulb and wet bulb temperatures of ambient are uncontrollable and hence for increasing the performance of the system the inlet air velocity and the water evaporation rates are to be enhanced by suitable methods. In general, water evaporates at its surface there by reducing the temperature of air consequently increasing the moisture. There are two methods possible to increase the surface area of water. (i) By installing more number of evaporative cooling pad, thereby increasing the wetted surface area (ii) By splitting of water into fine particle like a mist. The first concept is better when small air volumes are to be handled. It is not suitable for large air volumes, since it increases the cost and energy consumptions. In the present work, a centrifugal type atomizer is conceived and developed. Such an atomizer uses centrifugal force to split a

18 28 stream of water into fine mist, thereby increase the surface area of water many fold. The increased surface area facilitates faster evaporation. Thus, large air volumes can be evaporatively cooled. Thus, the proposed centrifugal type atomizer can evaporatively cool large air volumes, which can be used to cool large industrial sheds in tropical climates like India. This has provided the objectives for the present research work, mentioned in Section 1.4. The following chapters present the details and outcome of this research work.

Two Stage Indirect/Direct Evaporative Cooling

Two Stage Indirect/Direct Evaporative Cooling Two Stage Indirect/Direct Evaporative Cooling Abstract The performance of two-stage indirect/direct evaporative cooling system is experimentally investigated. For this purpose, a two-stage evaporative

More information

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011 Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage Kulkarni.R.K 1, Rajput S.P.S 2 1 SVPM College of Engineering, Malegaon(bk),

More information

ABSTRACT I. INTRODUCTION

ABSTRACT I. INTRODUCTION 2017 IJSRSET Volume 3 Issue 2 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Study the Effect on Evaporative Cooling for Different Contact Profiles of Wetted Surfaces

More information

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING DA Hindoliya and SC Mullick * Centre for Energy Studies, Indian

More information

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES THERMAL SCIENCE, Year 2011, Vol. 15, No. 2, pp. 467-475 467 EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES by Krishnasamy SENTHILKUMAR a* and Pss

More information

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.329 341, Article ID: IJMET_07_03_030 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3

More information

Design and Development of Combined Direct and Indirect Evaporative Cooling System

Design and Development of Combined Direct and Indirect Evaporative Cooling System ISSN 2395-1621 Design and Development of Combined Direct and Indirect Evaporative Cooling System #1 Pallavi B. Bedre, #2 H.U.Tiwari 1 pallavi.bedre@gmail.com 2 sharvay12 @rediffmail.com #12 Pimpri-Chinchwad

More information

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER International Journal of Scientific & Engineering Research, Volume 5, Issue 10, October-2014 676 Performance Evaluation of Alternative Evaporative Cooling Media Rajesh Maurya*, Dr. Nitin Shrivastava, Vipin

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection RESEARCH ARTICLE OPEN ACCESS Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection Tanuj Kumar Sahu 1, Vishal Gupta 2, Ajay Kumar Singh 3

More information

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS Chainarong Chaktranond *, and Peachrakha Doungsong Department of Mechanical Engineering, Faculty of Engineering,

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0232 ISBN: 978-83-7947-232-1 Experimental study of a novel dew point indirect evaporative cooler Wenhua Chen, Zhiwei Zhang, Jiayu Li,

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,

More information

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System 4 th International Conference On Building Energy Environment Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System J Y Park H W

More information

A review on Efficient Technique of Air-Conditioning Rajesh Kumar, Pravesh Mishra, Ram Raja

A review on Efficient Technique of Air-Conditioning Rajesh Kumar, Pravesh Mishra, Ram Raja A review on Efficient Technique of Air-Conditioning Rajesh Kumar, Pravesh Mishra, Ram Raja Abstract This is a review paper of Suryavanshi at al. Two stages evaporative cooling (TSEC) is an alternative

More information

Investigation of an evaporative air cooler using solar energy under Algerian climate

Investigation of an evaporative air cooler using solar energy under Algerian climate Available online at www.sciencedirect.com Energy Procedia 6 (2011) 573 582 MEDGREEN2011-LB Investigation of an evaporative air cooler using solar energy under Algerian climate S. Elmetenani a,*, M.L. Yousfi

More information

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

AN ENVIRONMENT FRIENDLY COOLING OPTION

AN ENVIRONMENT FRIENDLY COOLING OPTION AN ENVIRONMENT FRIENDLY COOLING OPTION Manoj Arya* 1, Anoop Arya and S.P.S. Rajput 2 1. Deptt. of Mechanical Engg. M.A.N.I.T. Bhopal (INDIA) 2. Deptt. of Electrical Engg. M.A.N.I.T. Bhopal (INDIA) * Email:

More information

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler International Journal of Thermal Technologies E-ISSN 2277 4114 2015 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of Operating Parameters on the

More information

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online): 2321-0613 Design of Compact Evaporative Cooler to Improve Cooling Efficiency and To Evaluate Performance

More information

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System Feasibility of a Liquid Desiccant Application in an Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, S.K.Han 1, S.Y. Cho 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang

More information

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant Proceedings of the World Congress on Momentum, Heat and Mass Transfer (MHMT 16) Prague, Czech Republic April 4 5, 216 Paper No. ENFHT 111 DOI: 1.11159/enfht16.111 Experimental Investigation of a Multi

More information

Modified Air Cooler with Split Cooling Unit

Modified Air Cooler with Split Cooling Unit Modified Air Cooler with Split Cooling Unit Nishant Dhanore 1, Krishna Shrivastava 2 1 SSBT s College of Engineering and Technology, Jalgaon (M.S.), India 2 Associate Professor, Mech. Engg. Dept. SSBT

More information

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1 TECHNICAL NOTE ON EVAPORATIVE COOLING Renato Lazzarin, President of the IIR s Commission E1 Principles The air has a variable water content from 0 (dry air) to a maximum value (saturated air) that strongly

More information

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India A Novel Design of Low Cost Domestic Cooling System-CoolAC Abhishek Gandhar Associate Prof., abhishek.gandhar@gmail.com Deekshant Bharti bravo9421@gmail.com Aditya Jain adityajn710@gmailcom Shiv Wadhwa

More information

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling Dr. Akash Langde 1, Zeeshan Jamal 2, Shahrukh Jamal 3, Mohammad Shumoil Ansari 4 1Professor, Department of Mechanical Engineering,

More information

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2 IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 07, 2015 ISSN (online): 2321-0613 Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan INDOOR CLIMATE DESIGN BASED ON FEEDBACK CONTROL OF HVAC COUPLED SIMULATION OF CONVECTON, RADIATION, AND HVAC CONTROL FOR ATTAINING GIVEN OPERATIVE TEMPERATURE Shuzo Murakami, Shinsuke Kato, and Taeyeon

More information

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER Gourav Roy; Taliv Hussain; Rahul Wandra Department of Mechanical Engineering, Lovely Professional

More information

Performance Optimization of the Evaporative Condenser Design

Performance Optimization of the Evaporative Condenser Design Performance Optimization of the Evaporative Condenser Design Mit. C. Patel P.G.Student, Mech. Engg.Dept. Institute of Technology, Nirma University, Ahmadabad, Prof. B. A. Shah Mechanical Engineering Department

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW Int. J. Mech. Eng. & Rob. Res. 2015 Ashish Kumar Chaturvedi and V N Bartaria, 2015 Review Article ISSN 2278 0149 www.ijmerr.com Vol. 4, No. 1, January 2015 2015 IJMERR. All Rights Reserved PERFORMANCE

More information

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE Pushpendra Singh 1, Vipin Shrivastava 2 1,2 Mechanical Engineering Department, Lakshmi Narain College of Technology (India) ABSTRACT

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 111 CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 7.1 INTRODUCTION Energy is the primary component to run any system in the world. According to

More information

A Review on Evaporative Cooling Technology

A Review on Evaporative Cooling Technology A Review on Evaporative Cooling Technology Bhushan D. Chaudhari 1, Tushar R. Sonawane 2, Shubham M. Patil 3, Prof. Anil Dube 4 Department of Mechanical Engineering, 1, 2, 3, 4 Sandip Institute of Technology

More information

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM Mr. Bashab Jyoti Phukan, S.K. Deb Assistant Professor, M.E. Department, Assam

More information

Solar Drying Techniques And Performance Analysis: A Review

Solar Drying Techniques And Performance Analysis: A Review IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 35-39 www.iosrjournals.org Solar Drying Techniques And Performance Analysis: A Review A.C. Jambhulkar,

More information

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,

More information

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical

More information

Management, 2nd Edition

Management, 2nd Edition Greenhouse Technology and Management, 2nd Edition Nicolas Castilla, PhD Research Coordinator, Department of Horticulture IFAPA (Institute for Agricultural Research and Training), Granada, Spain E-mail:

More information

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN ISSN 2229-5518 865 Abstract global warming and as a result, ambient temperature is rising significantly. Refrigeration and air- cooling systems are becoming necessary in almost all parts of India, even

More information

EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL

EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL Prof. R.S. Powar 1, Ms. A.G.Londhe 2 1,2 Department of Mechanical Engg., Dr.J.J.Magdum college of Engg.

More information

A Review on Potential of Indirect Evaporative Cooling System

A Review on Potential of Indirect Evaporative Cooling System IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 09 March 2017 ISSN (online): 2349-784X A Review on Potential of Indirect Evaporative Cooling System Malaysinh D. Borasiya

More information

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 3, ISSUE 4, APRIL 214 ISSN 2277-8616 Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates Ibrahim U. Haruna,

More information

Drying principles and general considerations

Drying principles and general considerations Drying principles and general considerations Drying Mechanisms In the process of drying heat is necessary to evaporate moisture from the grain and a flow of air is needed to carry away the evaporated moisture.

More information

Applied Thermal Engineering

Applied Thermal Engineering Applied Thermal Engineering 8 (2012) 117e12 Contents lists available at SciVerse ScienceDirect Applied Thermal Engineering journal homepage: www.elsevier.com/locate/apthermeng Increasing effectiveness

More information

Scholars Research Library

Scholars Research Library Available online at www.scholarsresearchlibrary.com Scholars Research Library Archives of Applied Science Research, 2010, 2 (1) 376-382 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-508X

More information

Design and Development of Modified Air Cooler and Storage System

Design and Development of Modified Air Cooler and Storage System Design and Development of Modified Air Cooler and Storage System J.Sabari priyan a, S.Sakthivel a, K.Sowndar Rajan a, S.Rajavel b* a (UG Scholar, Gnanamani College of Technology, Namakkal, Tamilnadu, India)

More information

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

Numerical Simulation of Window Air Conditioner

Numerical Simulation of Window Air Conditioner Numerical Simulation of Window Air Conditioner Mathewlal T 1, Kalpesh Patil 2, Gauri Thorat 3, Anisha Ankush 4, Ambarish Pote 5, Kartik Doshi 6 ( 1 Associate ProfessorMechanical Engineering Department,

More information

Adsorption refrigeration system using waste heat

Adsorption refrigeration system using waste heat Adsorption refrigeration system using waste heat 1 RISHI SREEKUMAR, 2 SANJEEV SINGH, 3 HIMANSHU SHEKHAR, 4 RAUSHAN KUMAR, 5 Dr. R. S. BINDU 1,2,3,4 BE Students, 5 Professor Mechanical Engineering Department

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

Performance Improvement of Air Conditioning System using Applications of Evaporative Cooling: A Review Paper

Performance Improvement of Air Conditioning System using Applications of Evaporative Cooling: A Review Paper Performance Improvement of Air Conditioning System using Applications of Evaporative Cooling: A Review Paper Kamlesh kumar Sharma 1, R.L. Gupta 2, Sanjay katarey 3 1 Assistant Professor, Department of

More information

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump To cite this article: Yefeng Liu et al 2018 IOP

More information

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment

More information

Green Practices Of Air Conditioning For Major Capital Cities Of India Using Advanced Evaporative Cooling

Green Practices Of Air Conditioning For Major Capital Cities Of India Using Advanced Evaporative Cooling International Journal of Engineering Trends and Technology (IJETT) Volume 18 Number 4 Dec 14 Green Practices Of Air Conditioning For Major Capital Cities Of India Using Advanced Evaporative Cooling M.M.Kulkarni

More information

ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION (VCR) BASED AIR CONDITIONING (AC) SYSTEM FOR HOT AND DRY CLIMATIC CONDITIONS IN OMAN

ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION (VCR) BASED AIR CONDITIONING (AC) SYSTEM FOR HOT AND DRY CLIMATIC CONDITIONS IN OMAN Journal of Thermal Engineering, Vol. 4, No. 3, pp. 1926-1938, April, 2018 Yildiz Technical University Press, Istanbul, Turkey ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION (VCR) BASED AIR CONDITIONING (AC)

More information

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube ISSN: 2347-3215 Volume 1 Number 4 (2013) pp. 46-54 www.ijcrar.com Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube Richa Soni 1*, P.K.Jhinge

More information

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance Study of Triple Concentric Pipe Heat Exchanger Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India

More information

Comfort and health-indoor air quality

Comfort and health-indoor air quality Comfort and health-indoor air quality 1 The human body has a complicated regulating system to maintain the human body temperature constant most of the time, which is 98.6 F (36.9 C) regardless of the environmental

More information

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area MMS DEZFOULI, SOHIF MAT, K.SOPIAN Solar Energy Research Institute (SERI, Universiti

More information

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015 International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015 ISSN: 2289-4152 Performance Evaluation of Vapour Compression Refrigeration System Using Double Effect Condensing

More information

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry Ing. Michal Pěnička Project leader: Doc. Pavel Hoffman CSc. Abstract The aim of this study was

More information

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Anna Pacak 1,*, Andrzej Jedlikowski 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of

More information

Passive Indirect Evaporative Cooler

Passive Indirect Evaporative Cooler Passive Indirect Evaporative Cooler Fernando F. Dall Agnol *, Aristides Pavani Center for Information Technology Renato Archer, Campinas, SP, Brazil *Corresponding author: fernando.dallagnol@cti.gov.br;

More information

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Available online   Journal of Scientific and Engineering Research, 2018, 5(11): Research Article Available online www.jsaer.com, 2018, 5(11):152-157 Research Article ISSN: 2394-2630 CODEN(USA): JSERBR Evaporation Cooling with Ceramics in Air-conditioning System Attila Szilágyi 1, István Farkas 2,

More information

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to

More information

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this lecture are to: 1. Importance of complete vapour compression refrigeration

More information

Dynamic performance of a novel dew point air conditioning for the UK buildings

Dynamic performance of a novel dew point air conditioning for the UK buildings *Corresponding author: xudongzhao@nottingham. ac.uk Dynamic performance of a novel dew point air conditioning for the UK buildings... Xudong Zhao *, Zhiyin Duan, Changhong Zhan and Saffa B. Riffat School

More information

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes

More information

Heat Transfer in Evacuated Tubular Solar Collectors

Heat Transfer in Evacuated Tubular Solar Collectors Heat Transfer in Evacuated Tubular Solar Collectors Graham L. Morrison, Indra Budihardjo and Masud Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 Australia

More information

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling

More information

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 4 (2013), pp. 441-448 International Research Publication House http://www.irphouse.com Experimental & Analytical

More information

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a CHAPTER 9 REFRIGERATION & AIR-CONDITIONING YEAR 2012 ONE MARK Common Data For Q. 1 and Q.2 A refrigerator operates between 120 kpa and 800 kpa in an ideal vapour compression cycle with R-134a as the refrigerant.

More information

Performance of solid desiccant-based evaporative cooling system under the climatic zones of India

Performance of solid desiccant-based evaporative cooling system under the climatic zones of India *Corresponding author: hemant_parmar1@ rediffmail.com Performance of solid desiccant-based evaporative cooling system under the climatic zones of India... H. Parmar 1 * and D.A. Hindoliya 2 1 Department

More information

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Marco Alexandre Onofre Dias This paper presents a model that was implemented

More information

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University 2 Objectives Differentiate between dry air and atmospheric air. Define and calculate

More information

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 12.A-1 A mixture of helium and water vapor is flowing through a pipe at T= 90 C and P = 150 kpa. The mole fraction of helium is y He = 0.80. a.) What is the relative humidity of the mixture? b.) What is

More information

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators IJIRST International Journal for Innovative Research in Science & Technology Volume 3 Issue 11 April 2017 ISSN (online): 2349-6010 Experimental Investigations of Different Types of Condensers on the Performance

More information

K.F. Fong *, C.K. Lee, T.T. Chow

K.F. Fong *, C.K. Lee, T.T. Chow Investigation on radiative load ratio of chilled beams on performances of solar hybrid adsorption refrigeration system for radiant cooling in subtropical city K.F. Fong *, C.K. Lee, T.T. Chow Building

More information

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road 517583 AUTONOMOUS QUESTION BANK (DESCRIPTIVE) Subject with Code : Refrigeration and Air Conditioning (16ME8806) Course & Branch:

More information

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning Ranga Vamshi and Anurag Bajpai GreenTree Building Energy (P) Ltd., B 67, Sector 67, Noida, UP, India. Problem Statement: Air-conditioning

More information

Shortcut Model for Predicting Refrigeration Cycle Performance

Shortcut Model for Predicting Refrigeration Cycle Performance 17 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 5, 15 Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Sharifah Rafidah Wan Alwi, Jun Yow Yong, Xia Liu Copyright 15, AIDIC Servizi S.r.l.,

More information

1.1. SCOPE OF THE WORK:

1.1. SCOPE OF THE WORK: Chapter 1: Introduction 1 1. INTRODUCTION 1.1. SCOPE OF THE WORK: Multi-stage refrigeration systems are an area of growing industrial importance in large plants. These systems are known to be large power

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,

More information

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER *

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER * PERFORMANCE ENHANCEMENT OF AIR CONDITIONER * K. B. Vijay, E. Naresh Kumar, T.Parameshwaran Pillai 1 Dept. of Mechanical Engineering. Anna University Chennai (BIT Campus), Tiruchirappalli 24 *corresponding

More information

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER Amrita Agrawal 1, Nalin Deshpande 2, Aakanksha Dubey 3 Department of Energy Maulana Azad National Institute of Technology (MANIT), Bhopal

More information

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,

More information

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS Staņislavs GENDELIS, Andris JAKOVIČS Laboratory for mathematical modelling of environmental

More information

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5 IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys

More information

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011)

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011) PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011) A research Proposal Submitted in Partial Fulfillment of the Requirements

More information

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University Scientific Principals and Analytical Model Charcoal Cooler Lisa Crofoot MECH 425, Queens University 1.0 Scientific Principles Evaporative cooling is based on the principle that water requires heat energy

More information