DESIGN & TECHNICAL MANUAL

Size: px
Start display at page:

Download "DESIGN & TECHNICAL MANUAL"

Transcription

1 AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW

2 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_

3 1. INDOOR UNIT CONTENTS 1. FEATURE WIRELESS REMOTE CONTROLLER SPECIFICATIONS DIMENSIONS WIRING DIAGRAMS CAPACITY TABLE COOLING CAPACITY HEATING CAPACITY FAN PERFORMANCE AIR VELOCITY DISTRIBUTION AIR FLOW OPERATION NOISE NOISE LEVEL CURVE SOUND LEVEL CHECK POINT ELECTRIC CHARACTERISTICS SAFETY DEVICES EXTERNAL INPUT & OUTPUT EXTERNAL INPUT EXTERNAL OUTPUT FUNCTION SETTING INDOOR UNIT (Setting by remote controller) OPTIONAL PARTS

4 - (1-1) - 111FEATURE MODEL ASU18RLF ASU24RLF FEATURES zhigh energy performance MODEL ASU18RLF ASU24RLF Seasonal Energy Efficiency Ratio (SEER) Heating Seasonal Performance Factor (HSPF) BTU/hW Energy Efficient Ratio (EER) MEASUREMENT CONDITIONS ANSI/ASHRAE STANDARD zall DC High efficiency layout DC fan motor Large air flow and quiet operation by new air flow path a b DC fan motor DC twin rotary compressor More compact compared with conventional model a b Front view zsuper quiet Air flow mode can be set in 4 steps and more detailed air flow setting is possible. zeasy maintenance Easy maintenance and always clean. Troublesome maintenance has been made easy. Since the front panel is easy to remove, maintenance is also easy. zmin. HEAT Operation The room temperature can be set to go no lower than 5 F, thus ensuring that the room does not get too cold when not occupied Caution) When the room temperature is higher than 5 F, MIN. HEAT operation does not start. Operation starts and maintains the room temperature at 5 F when the temperature drops below 5 F. 7 F MIN. HEAT Button ON MIN. HEAT Button ON 5 F Indoor unit operation START

5 - (1-2) - zpower diffuser Adoption of large power diffuser Strong vertical air flow provides powerful floor level heating. (ft) (ft) 46 o Power diffuser (full open) Outside air conditions:5.6 o F 6% Operation contents: Heating, Set temperature (Max set temp) o F, Air flow Hi, Vertical flap : Downward o 84 ( F) Healthy horizontal air flow does not blow cool air directly at the occupants in the room. (ft) 7 Power diffuser (ft) Outside air conditions: 95 o F 4% Operation contents: Cooling, Set temperature (Min set temp) o 65 ( F) 65 o F, Air flow Hi, Vertical flap : Upward Horizontal flap : Center zlow ambient outdoor temperature design (24Model) Low ambient outdoor temperature design Cooling to 115 F Heating to 75 F zcorresponds to maximum 164feet (5m) long piping

6 - (1 - ) - zair conditioner filter features Organic coating fin used heat exchanger Ion Deodorization Filter Apple-catechin Filter Pre Filter Antibacterial deodorizing pre-filter with special ceramic powder Long-life Ion Deodorization Filter Applecatechin Filter zeconomy operation Example : Cooling operation Temp. Economy operation Shift setting temp Economy operation is energy saving, as the set temperature of indoor unit is shifted by 2 F and the maximum electric value of the outdoor unit is suppressed. Set temperature Nomal operation Control maxmum current Time zblue fin heat exchanger Corrosion-resistance of the heat exchanger even in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger. Blue fin heat exchanger Cobalt Blue protection Standard chromate protection Aluminium base material Hydrophilic coating

7 - (1-4) - 222WIRELESS REMOTE CONTROLLER FEATURES Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible. Can be used jointly with wired remote controllers. Easy to change custom code (4 patterns). zbuilt-in timers Select from four different timer programs (On / Off / Program / Sleep). zprogram timer The program timer operates the ON and OFF timer once within a 24 hour period. zsleep timer The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping. Cooling operation / dry operation When the sleep timer is set, the set temperature automatically rises 2 F (1 C) every hour. The set temperature can rise up to a maximum of 4 F (2 C). Timer setting Heating operation When the sleep timer is set, the set temperature automatically drops 2 F (1 C) every minutes. The set temperature can drop to a maximum of 8 F (4 C). 2 F (1 C) 4 F (2 C) 6 F ( C) 8 F (4 C) 6min. min. 2 F (1 C) 4 F (2 C) 6min. 9min. Timer setting zswitching remote controller signal code After code change Mixed-up A B C D I.U. I.U. I.U. I.U. I.U. I.U. I.U. I.U. A B C D Code selector switch eliminates unit being wrongly switched. (Up to 4 codes can be set.) *I.U.=Indoor unit

8 - (1-5) - FUNCTIONS Display panel MODE button Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT). /Start / end R.C. custom code change. (Max 4 types) 2 MIN.HEAT button Set temp. button ( / ) Set remote controller custom code buttons Sets the indoor temp./ Sets R.C. custom code. 4 ECONOMY button 5 SLEEP button Pressed to select sleep timer. 6 FAN button Selects the fan speed (AUTO, HIGH, MED, LOW, QUIET). 7 START/STOP button Pressed to start and stop operation. 8 SET button (Vertical) Air flow direction vertical set button. 9 SET button (Horizontal) Air flow direction horizontal set button. 1 SWING button Air flow direction swing button. 11 TIMER MODE button Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET) 12 TIMER SET ( + / - ) button Sets the current time and on-off time. 1 CLOCK ADJUST button Sets the current time. 14 RESET button Used when replacing batteries. 15 TEST RUN button Used when testing the air conditioner after installation. 16 Signal transmitter 17 Temperature set display 18 Operating mode display 19 Sleep display 2 Transmit indicator 21 Fan speed display 22 Swing display 2 Timer mode display 24 Clock display 24 Note: Functions will be different due to type of indoor unit. For details, please see operation manual.

9 - (1-6) - SPECIFICATIONS Type WALL MOUNTED INVERTER HEAT PUMP Model name ASU18RLF ASU24RLF Power source 28/2V ~ 6Hz Available voltage range V ~ 6Hz Capacity Cooling Rated kw BTU/h 18, 22, Min-Max kw BTU/h 7, - 2, 9,9-27, Heating Rated kw BTU/h 21,6 27,6 Min-Max kw BTU/h 7, - 29, 7,5-6,2 Input power Rated Cooling Max.1.42 kw Rated Heating Max.2.5 Current Rated Cooling Max A Rated Heating Max EER Cooling kw/kw.9.66 BTU/hW COP Heating kw/kw.5.4 BTU/hW SEER Cooling BTU/hW HSPF Heating BTU/hW POWER FACTOR Cooling % Heating Moisture removal pints/h (l/h) 5.9 (2.8) 6. (.) High 541 (92) 659 (1,12) Cooling Med 45 (74) 5 (9) Low 65 (62) 45 (74) Fan Sound pressure level Heat exchanger type Enclosure Dimensions ( H W D ) Weight Connection pipe Operation range Remote controller type Drain pipe Airflow rate Heating Quiet High CFM (m /h) 6 (52) 541 (92) 65 (62) 677 (1,15) Med 45 (74) 5 (9) Low 65 (62) 45 (74) Quiet 18 (54) 65 (62) Type Q'ty Cross flow fan 1 Motor output W High 4 49 Med 7 42 Cooling Low 7 Quiet 28 db(a) High Med 7 42 Heating Low 7 Quiet 28 Dimensions (H W D) in. (mm) Main:15-7/8 x -/4 x 1-1/16 ( ) Sub: -5/16 x -/4 x 17/2 ( ) Fin pitch FPI Main:21, Sub:18 Rows x Stages Main:2 18, Sub:1 4 Pipe type Copper Fin type Aluminium Material Polystyrene Color WHITE Approximate color of MUNSELL N9.25/ Net mm inch 12-5/8 9-1/4 9 Gross mm inch 12-/ / /8 Net 1 (14) lb.(kg) Gross 4 (18) Size Liquid Ø /8 (Ø 9.52) in. (mm) Gas Ø 5 /8 (Ø 15.88) Method Flare Cooling F ( C) 64 to 9 (18 to 2) %RH 8 or less Heating F ( C) 88 () or less Wireless Material PVC Size mm (Reference in.) Outer diameter: 28 (1-/2) Inner diameter: 16 (5/8). Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 8 F (26.67 C)DB / 67 F (19.44 C)WB, and outdoor temperature of 95 F (5 C)DB / 75 F (2.9 C)WB. Heating : Indoor temperature of 7 F (21.11 C)DB / 59 F (15 C)WB, and outdoor temperature of 47 F (8. C)DB / 4 F (6.11 C)WB. Pipe length : 24.6ft(7.5m) [Outdoor unit - Indoor unit], Height difference : ft. (m) [Outdoor unit - Indoor unit]

10 - (1-7) - 444DIMENSIONS MODEL: ASU18RLF, ASU24RLF Unit : in (mm) 9-9/2 (998) 12-19/2 (2) 1 (25) 2-15/2 (52) 2-7/2 (59) 28-/8 (721) 8-1/2 (228) ø1-1/4 (2) ø5/8 (16) ø15/2 (12) 2-15/2 (52) 1-15/2 (7) 25/2 (2) Unit center 17-9/2 (49) 15-/4 (4) 5/8 (16) 1-1/2 x 7/16 (26 x 11) hole 15-1/4 (87) 9-9/16 (24) 4-7/16 (11) 2/2 x 7/16 (18 x 11) hole 2-15/16 (75) 6-11/16 (17) 5-1/8 (1) 2-15/16 (75) 6/2 x 2/2 (5 x 18): 14holes 12-19/2 (2): Unit size 1-19/2 (269) ø-5/2 (8) hole Piping inlet 6/2 x 1-1/2 (5 x 5): holes 4-1/16 (122) 6-25/2 (172) 17-1/4 (48) 15-5/8 (97) ø6/2 (5): 65holes for tapping screw 5-1/4 (1) 4-1/2 (126) 9-/8 (1): Unit size 2/2 x 7/16 (18 x 11) hole 1-1/2 x 7/16 (26 x 11) hole 1/16 x 6/2 (21 x 5): 14holes 15/2 (12) 1-6/2 () ø-5/2 (8) hole Piping inlet 1/2 x 6/2 (1 x 5): 4holes 1-2/2 (44) 1/2 (1) 5-7/8 (149) 7-/4 (197) 1-2/2 (272) 1-6/2 () ASU18RLF ASU24RLF Refrigerant pipe flare Liquid *ø 1/4 in. (6.5 mm) *ø 1/4 in. (6.5 mm) connection Gas *ø 1/2 in. (12.7 mm) ø 5/8 in. (15.88 mm) Drain hose connection Drain hose I.D. 15/2 in. (12 mm), O.D. 5/8 in. (16 mm) Drain hose : L=26-/8 in. (67mm) * When connecting to a connection pipe, an adapter provided as accessory along with the outdoor unit is required. Connection pipe Liquid Gas ASU18RLF ASU24RLF ø /8 in. (ø 9.52 mm) ø 5/8 in. (ø mm)

11 - (1-8) - INSTALLATION PLACE Unit : in (mm) 2-15/2 (6) or more -5/2 (8) or more Outline of unit 2-1/16 (52) or more -5/2 (8) or more 2-/2 (5) or more 4-2/2 (12) or more 59-1/16 (15) or more 7-7/8 (18) or more

12 - (1-9) - 555WIRING DIAGRAMS MODEL: ASU18RLF, ASU24RLF

13 - (1-1) - 666CAPACITY TABLE 66666COOLING CAPACITY MODEL: ASU18RLF AFR 541 Outdoor temperature Indoor temperature FDB FWB FDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI AFR : Air flow rate (CFM) TC : Total capacity (kbtu) SHC : Sensible Heat capacity (kbtu) PI : Power Input (kw) AFR 15. Outdoor temperature Indoor temperature CDB CWB CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI AFR : Air flow rate (m /min) TC : Total capacity (kw) SHC : Sensible Heat capacity (kw) PI : Power Input (kw) MODEL: ASU24RLF AFR 659 Outdoor temperature Indoor temperature FDB FWB FDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI AFR : Air flow rate (CFM) TC : Total capacity (kbtu) SHC : Sensible Heat capacity (kbtu) PI : Power Input (kw) AFR 18.7 Outdoor temperature Indoor temperature CDB CWB CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI AFR : Air flow rate (m /min) TC : Total capacity (kw) SHC : Sensible Heat capacity (kw) PI : Power Input (kw)

14 - (1-11) HEATING CAPACITY MODEL: ASU18RLF AFR 541 Outdoor temperature Indoor temperature FDB FDB FWB TC PI TC PI TC PI TC PI TC PI AFR : Air flow rate (CFM) TC : Total capacity (kbtu) PI : Power Input (kw) AFR 15. Outdoor temperature Indoor temperature CDB CDB CWB TC PI TC PI TC PI TC PI TC PI AFR : Air flow rate (m /min) TC : Total capacity (kw) PI : Power Input (kw) MODEL: ASU24RLF AFR 677 Outdoor temperature Indoor temperature FDB FDB FWB TC PI TC PI TC PI TC PI TC PI AFR : Air flow rate (CFM) TC : Total capacity (kbtu) PI : Power Input (kw) AFR 19.2 Outdoor temperature Indoor temperature CDB CDB CWB TC PI TC PI TC PI TC PI TC PI AFR : Air flow rate (m /min) TC : Total capacity (kw) PI : Power Input (kw)

15 - (1-12) - 777FAN PERFORMANCE 77777AIR VELOCITY DISTRIBUTION MODEL: ASU18RLF (ft)(m) 7 2 Unit : ft/s (m/s) Note: Fan speed : High Operation mode : FAN Voltage : 2V 1 7(2) (1) 2(.5) 1 7 (ft)(m) Unit : ft/s (m/s) TOP VIEW Vertical flap : Up Horizontal flap : Center (m) (ft) 7 2 7(2) 1 (ft)(m) (1) 2(.5) Unit : ft/s (m/s) SIDE VIEW Vertical flap : Up Horizontal flap : Center (m) (ft) 7 2 7(2) (1) 1 2(.5) 2(.5) 1 7(2) (1) (ft)(m) Unit : ft/s (m/s) TOP VIEW Vertical flap : Up Horizontal flap : Right & Left (m) (ft) (2) (1) 2(.5) SIDE VIEW Vertical flap : Down Horizontal flap : Center (m) (ft)

16 - (1-1) - MODEL: ASU24RLF (ft)(m) 7 2 Unit : ft/s (m/s) Note: Fan speed : High Operation mode : FAN Voltage : 2V 1 7(2) (1) 2(.5) 1 7 (ft)(m) Unit : ft/s (m/s) TOP VIEW Vertical flap : Up Horizontal flap : Center (m) (ft) 7 2 7(2) 1 (ft)(m) (1) 2(.5) Unit : ft/s (m/s) SIDE VIEW Vertical flap : Up Horizontal flap : Center (m) (ft) 7 2 (1) 1 7(2) 2(.5) 1 7(2) 2(.5) (ft)(m) (1) Unit : ft/s (m/s) TOP VIEW Vertical flap : Up Horizontal flap : Right & Left (m) (ft) (2) (1) 2(.5) SIDE VIEW Vertical flap : Down Horizontal flap : Center (m) (ft)

17 - (1-14) AIR FLOW MODEL: ASU18RLF zcooling Fan speed Number of rotations (r.p.m.) Air flow 92 m /h HIGH l/s 541 CFM 74 m /h MED l/s 45 CFM 62 m /h LOW l/s 65 CFM 52 m /h QUIET l/s 6 CFM zheating Fan speed Number of rotations (r.p.m.) Air flow 92 m /h HIGH l/s 541 CFM 74 m /h MED l/s 45 CFM 62 m /h LOW l/s 65 CFM 54 m /h QUIET l/s 18 CFM

18 - (1-15) - MODEL: ASU24RLF zcooling Fan speed Number of rotations (r.p.m.) Air flow 112 m /h HIGH l/s 659 CFM 9 m /h MED l/s 5 CFM 74 m /h LOW l/s 45 CFM 62 m /h QUIET l/s 65 CFM zheating Fan speed Number of rotations (r.p.m.) Air flow 115 m /h HIGH l/s 677 CFM 9 m /h MED l/s 5 CFM 74 m /h LOW l/s 45 CFM 62 m /h QUIET l/s 65 CFM

19 - (1-16) - 888OPERATION NOISE 88888NOISE LEVEL CURVE MODEL: ASU18RLF zcooling zheating Octave band sound pressure level, db:(db=.2µbar) High Quiet NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 Octave band sound pressure level, db:(db=.2µbar) High Quiet NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 NC , 2, 4, 8, Octave band center frequency,hz , 2, 4, 8, Octave band center frequency,hz MODEL: ASU24RLF zcooling zheating Octave band sound pressure level, db:(db=.2µbar) High Quiet NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 Octave band sound pressure level, db:(db=.2µbar) Quiet High NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 NC , 2, 4, 8, Octave band center frequency,hz , 2, 4, 8, Octave band center frequency,hz

20 - (1-17) SOUND LEVEL CHECK POINT 2ft. 7-5/8 in. (.8m) ft. -/8 in. (1m)

21 - (1-18) - 999ELECTRIC CHARACTERISTICS Model Name ASU18RLF ASU24RLF Power Supply Voltage V 28 / 2 ~ Frequency Hz 6 Max. Operating Current A. *1)Wiring Spec. Connection Cable AWG 14 Limited wiring length ft. (m) 167 (5) *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E5)

22 - (1-19) SAFETY DEVICES Protection form ASU18RLF Model ASU24RLF Circuit protection Current fuse (PCB).15A 25V Terminal protection Current fuse A 25V Fan motor protection Thermal protection program F ( C) OFF F ( C) ON

23 - (1-2) EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN14 Control input - See external CN16 - Operation status output input/output settings for details EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit. Operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a connector on the external control PC board and turning it ON. Initial starting after power turned on Starting other than at the left Operation mode Auto changeover Mode at previous operation Set temperature 76 F (24 C) Temperature at previous operation Air flow mode AUTO Mode at previous operation Up-down air direction (swing) Standard air direction (swing OFF) Air direction at previous operation Left-right air direction (swing) Standard air direction (swing OFF) Air direction at previous operation zcircuit diagram example Indoor control PC board Connected unit Connector 1 Ex.) Switch *ft. (1m) Signal Field supply * Make the distance from the PC board to the connected unit within ft. (1m). Contact capacity : 24VDC or more, 1mA or more. Please use the non-polar relays and switches. zwhen function setting is "Operation/Stop" mode Input signal Indoor unit ON OFF Operation Stop

24 - (1-21) - When function setting is "Forced stop" mode Input signal On Off Command Forced stop Normal Indoor unit Operation Stop Remote controller On On On Remote control operation invalidity zparts (Optional) Parts name External connect kit Model name UTY-XWZX Wire (External input) : UTY-XWZX

25 - (1-22) EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. zcircuit diagram example Indoor control PC board Connected unit Connector V DC V *ft. (1m) Ex.)Relay unit Ex.)Display Relay power supply Signal Field supply * Make the distance from the PC board to the connected unit within ft. (1m). Relay spec. : Max.24VDC, 1mA to less than 5mA. Indoor unit Output signal Operation Stop ON OFF zparts (Optional) Parts name External connect kit Model name UTY-XWZX Wire (External input) : UTY-XWZX

26 - (1-2) FUNCTION SETTING INDOOR UNIT (Setting by remote controller) The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. After the power is turned on, perform the FUNCTION SETTING according to the installation conditions using the remote controller. The settings may be selected between the following two: Function Number or Setting Value. Settings will not be changed if invalid numbers or setting values are selected. FUNCTION SETTING METHOD (for Wireless remote controller) Entering the Function Setting Mode While pressing the FAN button and SET TEMP. ( ) simultaneously, press the RESET button to enter the function setting mode. STEP 1 Setting the Remote controller Signal Code Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) The signal codes that are set through this process are applicable only to the signals in the FUNCTION SETTING. For details on how to set the signal codes through the normal process, refer to SELECTING THE REMOTE CONTROLLER SIGNAL CODE. 111 Press the SET TEMP. ( ) ( ) button to change the signal code between Match the code on the display to the air conditioner signal code. (initially set to ) (If the signal code does not need to be selected, press the MODE button and proceed to STEP 2.) 222 Press the TIMER MODE button and check that the indoor unit can receive signals at the displayed signal code. Press the MODE button to accept the signal code, and proceed to STEP 2. The air conditioner signal code is set to A prior to shipment. The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting, try each of the signal codes ( ) until you find the code which operates the air conditioner. STEP 2 Selecting the Function Number and Setting Value 111 Press the SET TEMP. ( ) ( ) buttons to select the function number. (Press the MODE button to switch between the left and right digits.) 222 Press the FAN button to proceed to setting the value. Press the FAN button again to return to the function number selection.) Press the SET TEMP. ( ) ( ) buttons to select the setting value. (Press the MODE button to switch between the left and right digits.) 444 Press the TIMER MODE button, and START/STOP button, in the order listed to confirm the settings. 555 Press the RESET button to cancel the function setting mode. 666 After completing the FUNCTION SETTING, be sure to turn off the power and turn it on again. Function number Setting value CAUTION After turning off the power, wait 1 seconds or more before turning on it again. The FUNCTION SETTING doesn t become effective if it doesn t do so.

27 - (1-24) - FUNCTION DETAILS Functions Wall mounted 1) Filter sign 2) Cooler room temperature correction ) Heater room temperature correction 4) Auto restart 5) Indoor room temperature sensor switching function 6) Remote controller signal code 7) External input control 1) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time setting for the filter sign display interval in the table below according to the amount of dust or debris in the room. If you do not wish the filter sign to be displayed, select the setting value for "No indication". (... Factory setting) Setting description Function number Setting value Standard Long interval 1 11 Short interval 2 No indication The filter sign interval time is different according to Indoor unit type as follows. Setting description Standard Long interval Short interval Wall mounted 4 hours 1 hours 2 hours 2) Cooler room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be selected as shown in the table below. (... Factory setting) Setting description Function number Setting value Standard Slightly lower control 1 Lower control 2 Warmer control ) Heater room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below. (... Factory setting) Setting description Function number Setting value Standard Lower control 1 1 Slightly warmer control 2 Warmer control

28 - (1-25) - 4) Auto restart Enable or disable automatic system restart after a power outage. (... Factory setting) Setting description Function number Setting value Yes 4 No 1 * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device. 5) Indoor room temperature sensor switching function (Only for Wired remote controller) The following settings are needed when use the control by Wired remote controller temperature sensor. (... Factory setting) Setting description Function number Setting value No 42 Yes 1 * If setting value is : Room temperature is controlled by the indoor unit temperature sensor. * If setting value is 1 : Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor. 6) Remote controller signal code Change the indoor unit Signal Code, depending on the remote controllers. (... Factory setting) Setting description Function number Setting value A B 1 44 C 2 D 7) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. (... Factory setting) Setting description Function number Setting value Operation/Stop mode (Setting forbidden) 46 1 Forced stop mode 2

29 - (1-26) - REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) 111 Press the START/STOP button until only the clock is displayed on the remote controller display. 222 Press the MODE button for at least five seconds to display the current signal code (initially set to ). Press the SET TEMP. ( ) ( ) button to change the signal code between. Match the code on the display to the air conditioner signal code. 444 Press the MODE button again to return to the clock display. The signal code will be changed. If no buttons are pressed within seconds after the signal code is displayed, the system returns to the original clock display. In this case, start again from step 1. The air conditioner signal code is set to A prior to shipment. Contact your retailer to change the signal code. The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting, try each of the signal codes ( ) until you find the code which operates the air conditioner.

30 - (1-27) OPTIONAL PARTS Exterior Parts name Model No. Summary Apple-catechin filter UTR-FA1-1 Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples. Ion deodorisation filter UTR-FA1-2 The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine-particle ceramic. SU MO TU WE TH FR SA AM PM Wired remote controller UTY-RNNUM Unit control is performed by wired remote controller. External connect kit UTY-XWZX Use to connect with various peripheral devices and air conditioner PC board.

31 2. SINGLE TYPE : AOU18RLXFW AOU24RLXFW DTR_AO77E_

32 CONTENTS SPECIFICATIONS DIMENSIONS REFRIGERANT CIRCUIT WIRING DIAGRAMS CAPACITY COMPENSATION RATE FOR PIPE LENGTH.AND HEIGHT DIFFERENCE ADDITIONAL CHARGE CALCULATION AIR FLOW OPERATION NOISE NOISE LEVEL CURVE SOUND LEVEL CHECK POINT ELECTRIC CHARACTERISTICS SAFETY DEVICES

33 - (2-1) - 111SPECIFICATIONS Type INVERTER HEAT PUMP Model name AOU18RLXFW AOU24RLXFW Power source 28/2V ~ 6Hz Available voltage range V ~ 6Hz Starting current A Airflow Cooling CFM 1,489 (2,5) 2,1 (,4) Fan rate Heating (m /h) 1,489 (2,5) 2,119 (,6) Type Q'ty Propeller fan 1 Motor output W 1 Sound pressure level Cooling db(a) Heating 5 55 Dimensions (H W D) in. 1-7/16 x 5-7/16 x 1-7/16 mm 798 x 9 x 6.4 Heat exchanger type Fin pitch FPI 2 Rows x Stages 2 8 Pipe type Copper Fin Type Aluminium Compressor Type Q'ty Rotary x 1 Motor output W 2,1 Type R41A Refrigerant lb.oz. 4lb.1.1oz. Charge kg 2.1 Refrigerant oil Type POE (RB68) Material Steel Enclosure BEIGE Color Approximate color of MUNSELL 1YR 7.5/1. mm 8 x 9 x Net Dimensions inch 2-/4 x 5-/8 x 1 (H W D) mm 97 x 15 x 445 Gross inch 8-1/4 x 41-1/2 x 17-1/2 Weight Net 15(61) lb.(kg) Gross 15(68) Size Liquid in. Ø/8 (Ø9.52) Gas (mm) Ø5/8 (Ø15.88) Connection pipe Method Flare Max. length ft. 164 (5) [chargeless:66(2)] Max. height difference (m) 98 () Operation range Cooling F 14 to115 (-1 to 46) to 115 (-18 to 46) Heating ( C) 5 to 75 (-15 to 24) to 75 (-18 to 24) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 8 F(26.67 C)DB / 67 F(19.44 C)WB,and outdoor temperature of 95 F(5 C)DB/75 F(2.9 C)WB. Heating : Indoor temperature of 7 F(21.11 C)DB / 59 F(15 C)WB,and outdoor temperature of 47 F(8. C)DB/4 F(6.11 C)WB. Pipe length : 24.6ft(7.5m) [Outdoor unit - Indoor unit], Height difference : ft. (m) [Outdoor unit - Indoor unit]

34 - (2-2) - 222DIMENSIONS MODEL: AOU18RLXFW, AOU24RLXFW Unit : in.(mm) Top view 5-/8 (9) (77) 1-1/4 (1) 1 () 1/2 (12) INSTALLATION PLACE 2-5/8 (6) or more 7/8 (21) 17-/8 (44) 2-/4 (8) Front view /8 (9) 25-5/8 (65) Air Flow 15-/4 (4) Side view 14-5/8 (7) Bottom view -7/8 (99) 7-/4 (196) 5-/4 (147) 6-/4 (17) When there are obstacles at the back or front sides. When there are obstacles at the back, side(s), and top. When there are obstacles at the back, side with the installation of more than one unit. 2-5/8 (6) or more -15/16 (1) or more -15/16 (1) or more 9-27/2 (25) or more (Service space) 11-1/16 () or more 9-27/2 (25) or more 9-27/2 (25) or more 11-1/16 () or more

35 - (2 - ) - REFRIGERANT CIRCUIT MODEL: AOU18RLXFW, AOU24RLXFW Muffler -Way valve (Large) Heat exchanger ( INDOOR ) -Way valve (Small) Pressure switch Compressor 4-Way valve Strainer Sub-accumulator Heat exchanger ( OUTDOOR ) Expansion valve Strainer Cooling Heating Refrigerant pipe diameter Liquid : /8" (9.52 mm) Gas : 5/8" (15.88 mm)

36 - (2-4) - 444WIRING DIAGRAMS MODEL: AOU18RLXFW

37 - (2-5) - MODEL: AOU24RLXFW

38 - (2-6) - CAPACITY COMPENSATION RATE FOR PIPE LENGTH 555 AND HEIGHT DIFFERENCE MODEL: AOU18RLXFW, AOU24RLXFW COOLING Ú1 Pipe length 5m 7.5m 1m 2m m 4m 5m 16ft. 25ft. ft. 66ft. 99ft. 11ft. 164ft. m 99ft m 66ft Indoor unit is upper 1m ft than outdoor unit. 7.5m 25ft Height difference H 5m 16ft m ft m -16ft Ú2-7.5m -25ft Indoor unit is under -1m -ft than outdoor unit -2m -66ft m -99ft Pipe length HEATING 5m 7.5m 1m 2m m 4m 5m 16ft. 25ft. ft. 66ft. 99ft. 11ft. 164ft. m 99ft Ú1 2m 66ft Indoor unit is upper 1m ft than outdoor unit. 7.5m 25ft Height difference H 5m 16ft m ft m -16ft Ú2-7.5m -25ft Indoor unit is under -1m -ft than outdoor unit -2m -66ft m -99ft Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe 1 Indoor unit is upper than outdoor unit. Connection pipe 2 Indoor unit is under than outdoor unit.

39 - (2-7) - 666ADDITIONAL CHARGE CALCULATION MODEL: AOU18RLXFW, AOU24RLXFW Refrigerant type R41A Refrigerant amount lb. oz. zrefrigerant CHARGE 4lb. 1.1oz. g 21 Total pipe length Additional charge ft. ~ m ~2 4 5 (MAX) oz. (Chargeless) g (Chargeless) oz./ft. (4g/m)

40 - (2-8) - 777AIR FLOW MODEL: AOU18RLXFW zcooling Number of rotations (r.p.m.) 62 Air flow 25 m /h 7 l/s 1489 CFM zheating Number of rotations (r.p.m.) Air flow 25 m /h 62 7 l/s 1489 CFM MODEL: AOU24RLXFW zcooling Number of rotations (r.p.m.) Air flow 4 m /h l/s 21 CFM zheating Number of rotations (r.p.m.) Air flow 6 m /h 85 1 l/s 2119 CFM

41 - (2-9) - 888OPERATION NOISE 88888NOISE LEVEL CURVE MODEL: AOU18RLXFW Octave band sound pressure level, db:(db=.2µbar) zcooling NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 Octave band sound pressure level, db:(db=.2µbar) zheating NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 NC , 2, 4, 8, Octave band center frequency,hz , 2, 4, 8, Octave band center frequency,hz MODEL: AOU24RLXFW zcooling 8 zheating Octave band sound pressure level, db:(db=.2µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 Octave band sound pressure level, db:(db=.2µbar) NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-5 NC- NC-25 NC-2 NC-15 NC , 2, 4, 8, Octave band center frequency,hz , 2, 4, 8, Octave band center frequency,hz

42 - (2-1) SOUND LEVEL CHECK POINT 9-/8 in. (1m)

43 - (2-11) - 999ELECTRIC CHARACTERISTICS Model Name AOU18RLXFW AOU24RLXFW Power Supply Voltage V 28 / 2~ Frequency Hz 6 *1) Max. Operating Current A Starting Current A Main Fuse (Circuit breaker) A 2 Current *2) Wiring Spec. Power Cable AWG 12 1 *) Limited wiring length ft.(m) 7 (21) 66 (2) *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E5) *) Limited Wiring Length: This is the wiring length in case voltage descent is less than 2%. When the wiring length becomes long, please select the wiring of a more larger diameter.

44 - (2-12) SAFETY DEVICES Circuit protection Protection form Current fuse (NEAR THE TERMINAL) Current fuse (MAIN PRINTED CIRCUIT BOARD) Model AOU18RLXFW AOU24RLXFW 5A 25V.15A 25V x 2 Fan motor protection Thermal protection program OFF : F ( C) ON : F ( C) High Pressure Protection Pressure Switch OFF : 4.2±.1MPa ON :.2±.15MPa Thermal protection program (COMPRESSOR TEMP.) OFF : 226 F (18 C) ON : 176 F (8 C) Compressor protection Thermal protection program (DISCHARGE TEMP.) OFF : 2 F (11 C) ON : After 7 minutes Thermal protection program (OUTDOOR TEMP.) (Cooling / Dry mode) OFF : 5 F (-15 C) ON : 14 F (-1 C) OFF : -1 F (-25 C) ON : -4 F (-2 C)

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_01 2013.02.28 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR G24LMLA OUTDOOR AO G24LALA 1. INDOOR UNIT : DTR_AR063E_01 2013.02.28 - (3) - 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AR C72LHTA AR C90LHTA OUTDOOR AO A72LALT AO A90LALT 1. INDOOR UNIT : AR C72LHTA AR C90LHTA DTR_AR061E_03 2013.11.08 1. INDOOR UNIT CONTENTS

More information

6. DUCT TYPE AR 60FUAK, AR 60UUAK

6. DUCT TYPE AR 60FUAK, AR 60UUAK R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor

More information

Hi-spec Design model. Photo : LT series

Hi-spec Design model. Photo : LT series Hi-spec Design model Photo : LT series 02 Hi-spec Design model * *LT series only 03 Human sensor Human sensor control * Even if people leave the room and forget to turn off the power, 20 minutes after

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA

More information

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL DTW_3SP001E_03 DESIGN & TECHNICAL MANUAL High power series ( 3 phase type ) FUTURE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS 3 PHASE TYPE : WO K112LAT, WO K140LAT, WO

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

2 &3-4 Head Multi System

2 &3-4 Head Multi System 2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY DESIGNER RANGE W A L L M O U N T E D SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu is a leading supplier

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFWH AOURLXFWH CONTENTS SPECIFICATIONS.................... DIMENSIONS........................

More information

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFW AOURLXFW CONTENTS SPECIFICATIONS.................... DIMENSIONS........................ REFRIGERANT SYSTEM

More information

CASSETTE TYPE AIR CONDITIONER

CASSETTE TYPE AIR CONDITIONER CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....

More information

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Concealed Duct Heat Pumps Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1 SERVICE MANUAL Inverter Wall Mounted Single Split MODELS Cooling Only FTKB09AXVJU FTKB12AXVJU FTKB18AXVJU FTKB24AXVJU FTKN09AXVJU FTKN12AXVJU FTKN18AXVJU FTKN24AXVJU Heatpump FTXB09AXVJU FTXB12AXVJU FTXB18AXVJU

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W183CSA5 AS-W243CSA5 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER DTV_OAE034E_03--CHAPTER01 2015.01.16 CONTENTS 1. FEATURES... A-01 2. SPECIFICATIONS... A-02 3. ELECTRIC CHARACTERISTICS... A-03 4. DIMENSIONS... A-05 5. REFRIGERANT CIRCUIT...A-11 6. WIRING... A-12 6-1.

More information

EDUS Heat Pump - D-Series

EDUS Heat Pump - D-Series EDUS 04-740 - Heat Pump - D-Series Split-System Room Air Conditioners D-Series The Single Split Duct-Free System Heat Pump FTXS09DVJU FTXS12DVJU FTXS15DVJU FTXS18DVJU FTXS24DVJU RX09FVJU RX12FVJU RX15FVJU

More information

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type H-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type H-Series Cooling Only Indoor Unit FTXS30HVJU

More information

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT

NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT FUJITSU HI-WALL RANGE NEW ZEALAND S MOST COMPREHENSIVE HI-WALL HEAT PUMP RANGE FUJITSU BETTER HEAT EFFICIENCY GUARANTEED BETTER HEAT FUJITSU S COMPREHENSIVE HI-WALL RANGE This range offers everything you

More information

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed. 1 TECHNICAL CHANGES MUZ09UN MUZ-A09NA MUZ12UN MUZ-A12NA MUH15TN MUZ-A15NA MUH17TN MUZ-A17NA MUH24WN MUZ-A24NA MU15TN MUY-A15NA MU17TN MUY-A17NA MU24WN MUY-A24NA 1. Outdoor unit model has been changed.

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems Ceiling Cassette Heat Pumps Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

HEAT & COOL MODEL (REVERSE CYCLE)

HEAT & COOL MODEL (REVERSE CYCLE) OPERATING MANUAL HEAT & COOL MODEL (REVERSE CYCLE) AIR CONDITIONER Duct Type Indoor Unit ARTG09LL ARTG12LL ARTG18LL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379439 CONTENTS SAFETY PRECAUTIONS... 1

More information

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing

More information

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch

More information

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT H I GH ENER GY EFFIC IEN C Y 5 YEAR F U LL P A R TS & LABOUR W A RRANTY WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE AIR Fujitsu General

More information

SiUS041638E. Service Manual. Inverter Pair Wall Mounted Type FTX-N Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041638E. Service Manual. Inverter Pair Wall Mounted Type FTX-N Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Cooling Only Indoor Unit

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

JUNE & 3-4 Head Multi System

JUNE & 3-4 Head Multi System JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities

More information

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC TECHNICAL CATALOGUE MONO SPLIT RAK-18PSC RAK-25PSC RAK-35PSC RAC-18WSC RAC-25WSC RAC-35WSC HITACHI Specifications in this catalogue are subject to change without prior notice in order for HITACHI to bring

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

FUJITSU FLOOR CONSOLES FUJITSU

FUJITSU FLOOR CONSOLES FUJITSU FUJITSU FLOOR CONSOLES Fujitsu s latest technology delivers powerful yet very efficient heating in these smart floor standing heat pumps. FUJITSU Better Heat Better efficiency Heat GuaranteeD WHAT IS FUJITSU

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO Domestic Air conditioner ON/OFF CAUTION 1. READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. Wall mounted Type Arc-Series HSU-14HR03/R2 2. THIS MANUAL IS USED BY QUALIFIED

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379583 CONTENTS SAFETY PRECAUTIONS... 2 FEATURES AND FUNCTIONS...

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11 M-SERIES SUBMITTAL DATA: MSZ-FH0NA & MUZ-FH0NA,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH0NA

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information