GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

Size: px
Start display at page:

Download "GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE"

Transcription

1 95%/93% AFUE HEATING INPUT: 46,000 5,000 BTU/H Standard Features / MULTI-POSITION, DUAL$AVER ONVERTIBLE, MULTI-SPEED GAS FURNAE The Goodman / 95%/93% AFUE Dual$aver onvertible, Multi-Speed, Multi-Position furnaces feature a patented aluminized-steel tubular heat exchanger and durable Silicon Nitride Hot Surface Ignition system. Patented TuffTube dual-diameter tubular heat exchanger with lifetime limited warranty plus 0-year limited furnace replacement warranty Two-stage gas valve with revolutionary new convertible technology that allows installer to activate the two-stage valve with the flip of a dipswitch Silicon Nitride igniter with patented adaptive learning control for maximum igniter life Furnace control board with self-diagnostics, color-coded low-voltage terminals, and provisions for electronic air cleaner and 4-volt humidifiers ontrol board stores the last five diagnostic codes in memory; simple push-button activation outputs the fault history to a flashing red LED Low constant fan allows homeowner to activate the low heat speed to efficiently circulate air throughout the home. Self-adjusting feature automatically adjusts to high or low stage based on outside temperature without an outdoor temperature sensor Dual-certified for sealed combustion direct vent (-pipe) or non-direct vent (-pipe) applications Easy-to-install top venting is standard; alternate flue/vent located on the right () All models comply with alifornia NOx emissions standards abinet Features Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish Foil-faced insulation lines the heat exchanger Designed for multi-position installation : upflow, horizontal left or right; : downflow, horizontal left or right Airtight solid bottom for side-return applications and easycut tabs for effortless removal in bottom air inlet applications onvenient left or right connection for gas & electric service oil and furnace fit flush for most installations ontents Nomenclature... Product Specifications...3 Dimensions...4 Blower Performance Specifications... 7 Wiring Diagrams...3 Accessories...5 For full warranty details, visit SS- /08 Supersedes 6/08

2 NOMENLATURE G M H ,5 6,7,8 4 9 B X A 0 Brand Revisions G Goodman Brand A Initial Release or Distinctions B st Revision nd Revision Airflow Direction Downflow/Horizontal D Dedicated Downflow NOx H High Airflow N Natural Gas K Dedicated Upflow X Low NOx M Upflow/Horizontal abinet Width Description A 4 V Two-Stage/Variable-speed B 7½ H Two-Stage/Multi-speed S Single-Stage/Multi-speed D 4½ E Two-Stage/X-3 Motor AFUE Maximum 0.5 ESP 95 95% 3, %+ 4, % 5,000 MBTU/h 045: 45,000 5: 5, : 70,000 40: 40, : 90,000 SS-

3 SPEIFIATIONS F Heating apacity 0453BXA 0703BXA 0704XA 0904XA 0905DXA 55DXA Input¹ 46,000 69,000 69,000 9,000 9,000 5,000 Natural Gas Output¹ 44,600 66,400 66,400 89,000 88,400 0,500 LP Gas Output¹ 39,330 58,995 58,995 78,660 78,660 98,35 AFUE² Available 0.5 ESP Temperature Rise Range ( F) irculator Blower Size (D x W) 0 x 8 0 x 8 0 x 0 0 x 0 x 0 x RPM ⅓ ⅓ ½ ½ ¾ ¾ Speed Vent Diameter³ 3 3 No. of Burners Filter Size (in²) Permanent Disposable Electrical Data Min. ircuit Ampacity Max. Overcurrent Device (amps) Ship Weight (lbs) Natural Gas BTU/h. For altitudes above,000, reduce input rating 4% for each,000 above sea level. Low-fire rate is 75% of high-fire rate DOE AFUE based upon Isolated ombustion System (IS) Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas ode NFPA 54/ANSI Z3. (in the USA) and the anada National Standard of anada, AN/SA B49. and AN/SA B4. (in anada). Permanent air filter size is based on 600 FPM velocity. heck with filter manufacturer for specific details. Minimum ircuit Ampacity = (.5 x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. Must use fuses or HAR-type circuit breakers of the same size as noted. Notes: All furnaces are manufactured for use on 5 VA, 60 Hz, single-phase electrical supply. Gas Service onnection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. SS- 3

4 SPEIFIATIONS F Heating apacity 0453BXA 0703BXA 0704XA 0904XA 0905DXA 55DXA Natural Gas Input¹ 46,000 69,000 69,000 9,000 9,000 5,000 Natural Gas Output¹ 4,800 64,400 64,400 86,000 86,000 06,500 LP Gas Output¹ 38,50 57,753 57,753 77,004 77,004 96,55 AFUE² Available 0.5 ESP Temperature Rise Range ( F) irculator Blower Size (D x W) 0 x 8 0 x 8 0 x 0 0 x 0 x 0 x RPM ⅓ ⅓ ½ ½ ¾ ¾ Speed Vent Diameter³ No. of Burners Filter Size (in) Permanent Disposable Electrical Data Min. ircuit Ampacity Max. Overcurrent Device (amps) Ship Weight (lbs) Natural Gas BTU/h. For altitudes above,000, reduce input rating 4% for each,000 above sea level. Low-fire rate is 75% of high-fire rate DOE AFUE based upon Isolated ombustion System (IS) Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas ode NFPA 54/ANSI Z3. (in the USA) and the anada National Standard of anada, AN/SA B49. and AN/SA B4. (in anada). Permanent air filter size is based on 600 FPM velocity. heck with filter manufacturer for specific details. Minimum ircuit Ampacity = (.5 x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. Must use fuses or HAR-type circuit breakers of the same size as noted. Notes: All furnaces are manufactured for use on 5 VA, 60 Hz, single-phase electrical supply. Gas Service onnection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. 4 SS-

5 DIMENSIONS AIR DISHARGE AIR DISHARGE AIR INTAKE PIPE " PV / RIGHT SIDE DRAIN LINE HOLES 5/8 UNFOLDED FLANGES UNFOLDED FLANGES FOLDED FLANGES FOLDED FLANGES RIGHT SIDE VIEW Model A B D E 0453BXA 7½ 6 3⅛ ⅛ 3⅝ 0703BXA 7½ 6 3⅛ ⅛ 3⅝ 0704XA 9½ 6⅛ 6 7½ 0904XA 9½ 6⅛ 6 7½ 0905DXA 4½ 3 0⅝ 9⅜ 0⅞ 55DXA 4½ 3 0⅝ 9⅜ 0⅞ Notes: Installer must supply one or two PV pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must be either or 3 in diameter, depending upon furnace input, number of elbows, length of run, and installation ( or pipes). The optional combustion air pipe is dependent on installation/code requirements and must be or 3 diameter PV. Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. onversion kits for high-altitude natural gas operation are available. ontact your Goodman distributor or dealer for details. Installer must supply the following gas line fi ttings, according to which entrance is used: Left: One 90º street elbow; one ½ pipe nipple; one 90º elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve Installations using a bottom return: Failure to unfold duct fl anges will reduce airfl ow area by approximately 8%. This could result in performance and noise issues. MINIMUM LEARANES TO OMBUSTIBLE MATERIALS Position Sides Rear Front Bottom Flue Top Upfl ow Horizontal = If placed on combustible fl oor, the fl oor MUST be wood ONLY. For servicing or cleaning, a 4 front clearance is recommended. Unit connections (electrical, fl ue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Approved for line contact in the horizontal position SS- 5

6 DIMENSIONS AIR Model A B D E 0453BXA 7½ 6 ⅜ 4½ BXA 7½ 6 ⅜ 4½ XA 9½ 6⅜ 8 9½ 0904XA 9½ 6⅜ 8 9½ 0905DXA 4½ 3 0⅜ ½ 3 55DXA 4½ 3 0⅜ ½ 3 Notes: Installer must supply one or two PV pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must be either or 3 in diameter, depending upon furnace input, number of elbows, length of run, and installation ( or pipes). The optional combustion air pipe is dependent on installation/code requirements and must be or 3 diameter PV. Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. onversion kits for high-altitude natural gas operation are available. ontact your Goodman distributor or dealer for details. Installer must supply the following gas line fi ttings, according to which entrance is used: Left: One 90º street elbow; one ½ pipe nipple; one 90º elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve Installations using a bottom return: Failure to unfold duct fl anges will reduce airfl ow area by approximately 8%. This could result in performance and noise issues. MINIMUM LEARANES TO OMBUSTIBLE MATERIALS Position Sides Rear Front Bottom Flue Top Downflow 0 0 N 0 Horizontal = ombustible: If placed on combustible fl oor, the fl oor MUST be wood ONLY. N = Non-ombustible: A combustible fl oor sub-base must be used for installation on combustible fl ooring Notes: For servicing or cleaning, a 4 front clearance is recommended. Unit connections (electrical, fl ue and drain) may necessitate greater clearances than the minimum clearances listed below. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. 6 SS-

7 BLOWER PERFMANE SPEIFIATIONS (FM & Temperature Rise vs. External Static Pressure) Model Motor Speed Tons A at 0.5 ESP External Static Pressure, (Inches Water olumn) FM Rise FM Rise FM Rise FM Rise FM Rise FM FM FM High 3,35 9,38 30,60 3,0 33,8 35, BXA Med.5,4 3,7 34,3 35,064 37, Med-Lo Low High 3,449 4,409 4,36 45,73 47,0 49,94,36, BXA Med.5,9 50,7 5,4 5,094 54, Med-Lo Low High 4,069 9,965 30,87 3,756 34,66 36,549,45, XA Med 3.5,75 34,74 34,667 36,603 37,488 40,40,90,08 Med-Lo 3,437 4,437 4,47 4,369 43,30 45,56, Notes: Low.5,84 50,77 50,6 5,3 5,095 54, FM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most applications, about 400 FM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPEIFIED ON THE RATING PLATE. The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of the recommended maximum heating static pressure. The above chart is for furnaces installed at feet. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular FM, while ESP at the FM will be lower. SS- 7

8 BLOWER PERFMANE SPEIFIATIONS (ONT.) (FM & Temperature Rise vs. External Static Pressure) Model Motor Speed Tons A at 0.5 ESP External Static Pressure, (Inches Water olumn) FM Rise FM Rise FM Rise FM Rise FM Rise FM FM FM High 4,970 40,874 4,757 45,667 48,566 5,43,334,8 0904XA Med 3.5,73 46,650 48,57 50,50 5,48 56,33,,079 Med-Lo 3,439 55,4 56,370 58,37 60,60 63,66, Low.5,83 67,55 69, 7,08 7,06 75, High 5,47 37,4 37,057 39,030 39,978 40,889,784, DXA Med 4,675 47,686 47,640 48,63 49,557 5,50,455,360 Med-Lo 3.5,489 53,470 54,436 55,409 56,36 58,38,43,30 Low 3,307 6,65 63,34 64,03 66,68 68,096, High 5,34 46,03 47,09 48,94 5,906 5,88,733,65 55DXA Med 4,678 58,643 60,643 60,577 6,57 64,489,43,339 Med-Lo 3.5,453 68,440 68,46 69,363 7,349 73,34,53,05 Notes: Low 3,59 78,39 79,0 80,8 83,59 85,8,08,05 FM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most applications, about 400 FM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPEIFIED ON THE RATING PLATE. The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of the recommended maximum heating static pressure. The above chart is for furnaces installed at feet. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular FM, while ESP at the FM will be lower. 8 SS-

9 BLOWER PERFMANE SPEIFIATIONS (ONT.) BTU OUTPUT vs TEMPERATURE RISE HART 600 FM FM FMULAS BTU OUTPUT = FM x.08 x RISE RISE = BTU OUTPUT.08 FM OUTPUT BTU/HR x 000 TEMPERATURE RISE SS- 9

10 BLOWER PERFMANE SPEIFIATIONS (FM & Temperature Rise vs. External Static Pressure) Model Motor Speed Tons A at 0.5 ESP External Static Pressure, (Inches Water olumn) FM Rise FM Rise FM Rise FM Rise FM Rise FM FM FM High 3,35 9,38 30,60 3,0 33,8 35, BXA Med.5,4 3,7 34,3 35,064 37, Med-Lo Low High 3,449 4,409 4,36 45,73 47,0 49,94,36, BXA Med.5,9 50,7 5,4 5,094 54, Med-Lo Low High 4,069 9,965 30,87 3,756 34,66 36,549,45, XA Med 3.5,75 34,74 34,667 36,603 37,488 40,40,90,08 Med-Lo 3,437 4,437 4,47 4,369 43,30 45,56, Low.5,84 50,77 50,6 5,3 5,095 54, High 4,970 40,874 4,757 45,667 48,566 5,43,334,8 0904XA Med 3.5,73 46,650 48,57 50,50 5,48 56,33,,079 Med-Lo 3,439 55,4 56,370 58,37 60,60 63,66, Low.5,83 67,55 69, 7,08 7,06 75, High 5,47 37,4 37,057 39,030 39,978 40,889,784, DXA Med 4,675 47,686 47,640 48,63 49,557 5,50,455,360 Med-Lo 3.5,489 53,470 54,436 55,409 56,36 58,38,43,30 Low 3,307 6,65 63,34 64,03 66,68 68,096, High 5,34 46,03 47,09 48,94 5,906 5,88,733,65 55DXA Med 4,678 58,643 60,643 60,577 6,57 64,489,43,339 Med-Lo 3.5,453 68,440 68,46 69,363 7,349 73,34,53,05 Notes: Low 3,59 78,39 79,0 80,8 83,59 85,8,08,05 FM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return fi lters, this chart assumes both fi lters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most jobs, about 400 FM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPEIFIED ON THE RATING PLATE. The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of the recommended maximum heating static pressure. The above chart is for U.S. furnaces installed at feet. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular FM, while ESP at the FM will be lower. 0 SS-

11 BLOWER PERFMANE SPEIFIATIONS (ONT.) BTU OUTPUT vs TEMPERATURE RISE HART 600 FM FM FMULAS BTU OUTPUT = FM x.08 x RISE RISE = BTU OUTPUT.08 FM OUTPUT BTU/HR x 000 TEMPERATURE RISE SS-

12 DUAL$AVER ONFIGURATION & OPERATION THERMOSTATS Model HT8-60 H70TG HSATG H0TWR Description ooling/heating, Mechanical ooling/heating, Digital, Non-programmable ooling/heating, Mechanical Heating Only, Mechanical SS-

13 WIRING DIAGRAM 4V THERMOSTAT ONNETIONS BR BR 4 VA HUMIDIFIER G R W DIAGNOSTI LED 4 VA 5 VA 5 VA HOT AND PARK TERMINALS OOL-H APAIT INTEGRATED ONTROL MODULE ON FUSE OFF ND STAGE DELAY MODE HEAT OFF DELAY FATY SETTINGS SHOWN * Y SEE NOTE 6 HEAT-H SEE NOTE 4 * * * XFMR-H (HI) BL (MED) (MED LOW) (LOW) LINE-H FS 3 XFMR-N VA NEUTRAL TERMINALS PK YL PK BL YL BR GR PK BL YL GR BLOWER OMPARTMENT DO SWITH (OPEN EN DO OPEN) BR 4V THERMOSTAT ONNETIONS INTEGRATED ONTROL MODULE G Y W R TO MIRO TH (3) XFMR-H FS IGN IND TR (6) (8) MV (9) MVH () MVL() PS (0) PSO (4) HLI (7) HLO () RO () RO (5) LO HEAT-H HI HEAT-H HUMIDIFIER NO FLAME SENS HOT SURFAE IGNITER ID BLWR FRONT OVER PRESSURE SWITH OOL-H 4 VA 5 VA IRULAT BLWR INTEGRATED ONTROL MODULE NO 40 VA TRANSFMER IR-N XFMR-N ID-N GAS HI VALVE PM ID BLOWER PRESSURE SWITH INTEGRATED ONTROL MODULE BLOWER OMPARTMENT PU EA-H ELETRONI AIR LEANER EA-N BURNER OMPARTMENT MANUAL RESET AUXILIARY LIMITS () IN UPFLOW BLOWER DEK () IN 'FLOW BLOWER HOUSING INDUED DRAFT BLOWER LINE-H LINE-N JUNTION BOX DO SWITH DISONNET PU N O YL PK BL L N TO 5VA/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE ID BLOWER PRESSURE SWITH IRUIT ONNET HOT SURFAE IGNITER 4 VA HUMIDIFIER PM HI 3 BR GAS VALVE N O FRONT OVER PRESSURE SWITH GR BL FLAME SENS JUNTION BOX N L STEADY ON = NMAL OPERATION OFF = ONTROL FAILURE FLASH = FLASHES = PRESSURE SWITH STUK LOSED 3 FLASHES = PRESSURE SWITH STUK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = 7 FLASHES = LOW FLAME SIGNAL ONTINUOUS/RAPID FLASHES = REVERSED 5 VA POLARITY LOW VOLTAGE (4V) LOW VOLTAGE FIELD HI VOLTAGE (5V) HI VOLTAGE FIELD JUNTION TERMINAL INTERNAL TO INTEGRATED ONTROL PLUG ONNETION EQUIPMENT FIELD FIELD SPLIE SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. DEVIE OL ODES: YL YELLOW ANGE PU PURPLE GN GREEN BLAK PK PINK BR BROWN ITE BL BLUE GRAY RED 040F00098 REV.-- NOTES:. SET HEAT ANTIIPAT ON ROOM THERMOSTAT AT 0.7 AMPS.. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BE USED EN SERVIING. 3. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BE REPLAED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 05. USE OPPER ONDUTS ONLY. 4. IF HEATING AND OOLING BLOWER SPEEDS ARE NOT THE SAME, DISA JUMPER BEFE ONNETING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLAED ON "PARK" TERMINALS OF INTEGRATED ONTROL TAPED. 5. UNIT MUST BE PERMANENTLY GROUNDED AND ONFM TO N.E.. AND LOAL ODES. 6. TO REALL THE LAST 5 FAULTS, MOST REENT TO LEAST REENT, DEPRESS SWITH F ME THAN SEONDS ILE IN STANDBY (NO THE RMOSTAT IN PUTS) Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS- 3

14 WIRING DIAGRAM 4V THERMOSTAT ONNETIONS BR BR 4 VA HUMIDIFIER G W R DIAGNOSTI LED 4 VA 5 VA 5 VA HOT AND PARK TERMINALS OOL-H APAIT INTEGRATED ON FUSE ONTROL MODULE OFF ND STAGE DELAY MODE HEAT OFF DELAY FATY SETTINGS SHOWN * Y SEE NOTE 6 HEAT-H SEE NOTE 4 (HI) * * * XFMR-H BL (MED) (MED LOW) (LOW) LINE-H FS VA NEUTRAL TERMINALS PK YL PK BL YL BR GR PK BL YL GR BLOWER OMPARTMENT DO SWITH (OPEN EN DO OPEN) BR 4V THERMOSTAT ONNETIONS INTEGRATED ONTROL MODULE G Y W R TO MIRO TH (3) XFMR-H FS IGN IND TR (6) (8) MV (9) MVH () MVL() PS (0) PSO (4) HLI (7) HLO () RO () RO (5) HI LO HEAT-H HEAT-H HUMIDIFIER NO FLAME SENS HOT SURFAE IGNITER ID BLWR FRONT OVER PRESSURE SWITH OOL-H 4 VA 5 VA IRULAT BLWR INTEGRATED ONTROL MODULE NO 40 VA TRANSFMER GAS HI VALVE PM ID BLOWER PRESSURE SWITH LINE NEUTRALS INTEGRATED ONTROL MODULE BLOWER OMPARTMENT PU EA-H ELETRONI AIR LEANER BURNER OMPARTMENT MANUAL RESET AUXILIARY LIMITS () IN UPFLOW BLOWER DEK () IN 'FLOW BLOWER HOUSING INDUED DRAFT BLOWER LINE-H DO SWITH JUNTION BOX DISONNET PU N O YL PK BL L N TO 5VA/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE ID BLOWER PRESSURE SWITH IRUIT ONNET HOT SURFAE IGNITER 4 VA HUMIDIFIER PM HI 3 BR GAS VALVE N O FRONT OVER PRESSURE SWITH GR BL FLAME SENS JUNTION BOX N L STEADY ON = NMAL OPERATION OFF = ONTROL FAILURE FLASH = FLASHES = PRESSURE SWITH STUK LOSED 3 FLASHES = PRESSURE SWITH STUK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = 7 FLASHES = LOW FLAME SIGNAL ONTINUOUS/RAPID FLASHES = REVERSED 5 VA POLARITY LOW VOLTAGE (4V) LOW VOLTAGE FIELD HI VOLTAGE (5V) HI VOLTAGE FIELD JUNTION TERMINAL INTERNAL TO INTEGRATED ONTROL PLUG ONNETION EQUIPMENT FIELD FIELD SPLIE SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. DEVIE OL ODES: YL YELLOW ANGE PU PURPLE GN GREEN BLAK PK PINK BR BROWN ITE BL BLUE GRAY RED 040F00098 REV. B NOTES:. SET HEAT ANTIIPAT ON ROOM THERMOSTAT AT 0.7 AMPS.. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BE USED EN SERVIING. 3. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BE REPLAED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 05. USE OPPER ONDUTS ONLY. 4. IF HEATING AND OOLING BLOWER SPEEDS ARE NOT THE SAME, DISA JUMPER BEFE ONNETING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLAED ON "PARK" TERMINALS OF INTEGRATED ONTROL TAPED. 5. UNIT MUST BE PERMANENTLY GROUNDED AND ONFM TO N.E.. AND LOAL ODES. 6. TO REALL TH E LAST 5 FAULTS, MOST REENT TO LEAST REENT, DEP RESS SWITH F ME THAN SEONDS W HILE IN STANDBY (NO THERMOSTA T INPUTS) Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARNING High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 4 SS-

15 AESSIES Accessory Description 0453BXA 0703BXA 0704XA 0904XA 0905DXA 55DXA LPM-03B LP onversion Kit (Gas Valve) LPM-05 LP onversion Kit (Springs & Orifi ce) LPLP0 LP Gas Low Pressure Kit GSAS Electronic Air leaners (-0, -, -, -8) GMU Media Air leaners (60, 00, 65, 05) HANG High Altitude Natural Gas Kit HANG High Altitude Natural Gas Kit HALP0 High Altitude LP Gas Kit HAPS7 High Altitude Pressure Switch Kit EFR0 External Filter Rack DVK-0 Horizontal/Vertical oncentric Vent Kit ( ) DVK-30 Horizontal/Vertical oncentric Vent Kit (3 ) 070K00000S Flush-mount Vent Kit Indicates accessories available for this model Indicates 7,00 to 9,000 altitude Indicates 9,00 to,000 altitude 3 Indicates 7,00 to,000 altitude Note: All installations above 7,000 require a pressure switch change. For installation in anada, furnaces are certifi ed only to 4,500. SS- 5

16 AESSIES Accessory Description 0453BXA 0703BXA 0704XA 0904XA 0905DXA LPM-03B LP onversion Kit (Gas Valve) LPM-05 LP onversion Kit (Springs & Orifi ce) LPLP0 LP Gas Low Pressure Kit GSAS Electronic Air leaners (-0, -, -, -8) GMU Media Air leaners (60, 00, 65, 05) HANG High Altitude Natural Gas Kit HANG High Altitude Natural Gas Kit HALP0 High Altitude LP Gas Kit HAPS7 High Altitude Pressure Switch Kit EFR0 External Filter Rack 55DXA DVK-0 Horizontal/Vertical oncentric Vent Kit ( ) DVK-30 Horizontal/Vertical oncentric Vent Kit (3 ) Flush-mount Vent Kit Indicates accessories available for this model Indicates 7,00 to 9,000 altitude Indicates 9,00 to,000 altitude 3 Indicates 7,00 to,000 altitude Notes All installations above 7,000 require a pressure switch change. For installation in anada, furnaces are certifi ed only to 4,500. Downflow Floor base: When the model is installed directly on a wood fl oor, a downfl ow fl oor base must be used. Those model numbers are: FB7, FB and FB4. Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 008 Goodman Manufacturing ompany, L.P. Houston, Texas Printed in the USA. 6 SS-

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams...

More information

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams...

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

ComfortNet -Compatible

ComfortNet -Compatible GMV8 omfortnet -ompatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve

More information

AMVM97 (B) / ACVM97 (B)

AMVM97 (B) / ACVM97 (B) (B) / (B) Heating Input: 60,000 0,000 BTU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 flow Specifications... 6 Wiring Diagram...

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

TECHNICAL MANUAL. GMH95 40 95% Gas Furnace TEHNIAL MANUAL AL 40" 95% Gas Furnace Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual.

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams... 0

More information

GKS9 40" 90% Gas Furnaces

GKS9 40 90% Gas Furnaces TECHNICAL MANUAL AL 40" 90% Gas Furnaces Refer to Service Manual RS6610004* for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service

More information

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS600004 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. AMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL MANUAL. GMH8 39 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal TECHNICAL MANUAL AL GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal Refer to Service Manual RS660004 for installation, operation, and troubleshooting information.

More information

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units TEHNIAL MANUAL AL TM AV9/AMV95 GV9/GMV95 90% UP TO 96% Gas Furnace Units Refer to Service Manual RS6612002 for troubleshooting information. Refer to the appropriate Parts atalog for part number information.

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006for troubleshooting information. All safety information must

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

Technical Information

Technical Information A I R COMMA ND GAS FURNACE Technical Information 40" 80% Gas Furnaces GUIC EA/EX Refer to Service Manual RS660000 Rev. 2 for installation, operation, and troubleshooting information. All safety information

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TECHNICAL INFORMATION MANUAL AMS9/ACS9 40" 90% Gas Furnace Model and Manufacturing numbers listed on page 3. Refer to Service Manual RS660000x for installation, operation, and troubleshooting information.

More information

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h MBV Variable-Speed, omfortnet - ompatible Modular Blowers ooling apacity: 8,000-60,000 BTU/h Standard Features ompatible with the omfortnet ommunication System family of products Variable-speed EM blower

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TECHNICAL INFORMATION MANUAL GDS8, GMS8, GHS8 40" 80% Gas Furnace Units Models listed on page 3 Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006) T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal

GME8 33-3/8 80% Gas Furnace Upflow/Horizontal TECHNICAL MANUAL AL GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal Refer to current Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004) H9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe). Direct Vent Furnace 4 high with wider cabinets, for noise reduction and ease of installation. Factory shipped as natural

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

More information

Downflow/Horizontal Right Induced Draft Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion

More information

T9MPV SmartComfort VS90 Product Specifications

T9MPV SmartComfort VS90 Product Specifications 90+ Variable Speed Two -Stage Heating Furnace FLEXIBILITY Supports two--stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40 high with wider cabinets, for ease of installation

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-10 General

More information

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev. 036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Installation Instructions

Installation Instructions Installation Instructions B5BV Series Electric Furnaces For HUD approved installations in manufactured homes and modular homes These instructions are intended to assist qualified individuals experienced

More information

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,

More information

40 Residential Gas Furnace Operation

40 Residential Gas Furnace Operation 40 Residential Gas Furnace Operation Model Evolution/Nomenclature Heating Sequence of Operation Schematics Ignition Systems Service/Troubleshooting American Standard Inc. 999 Preface Air Conditioning and

More information

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price Product Data 58RAV High-Efficiency Downflow/Horizontal Induced-ombustion Gas Furnace Input apacities: 50,000 thru 5,000 Btuh 80% AFUE At Budget Price DOWNFLOW HORIZONTAL arrier provides an 80% Annual Fuel

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

Energy Saving. Space Saving.

Energy Saving. Space Saving. Energy Saving. Space Saving. An Unbeatable Combination! 92% Gas Furnace Comfort, efficiency, and dependability make an unbeatable combination in the 92% gas furnace! Energy Savings Two heat exchangers

More information

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information

Cooling Capacity CFM range

Cooling Capacity CFM range R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information