2 AIR COOLED SPLIT SYSTEMS LIGHT COMMERCIAL RANGE UN-PRC00-EN 3

3 Air-cooled split systems Air-cooled condensing units TTA/TWA Blower units Max. length Max. level difference Line diameter (m) (m) (inches) Outdoor unit L3 D2 D Gas Liquid TTA TTA TTA TTA TTA TTA TTA TTA TTA TTA TWA TWA TWA TWA TWA TWA TWA TWA TWA Maximum line lengths and diameters Compressor unit D L3 D2 Blower unit 4 UN-PRC00-EN

4 SPLIT SYSTEMS TR Large capacity indoor and outdoor units. For use within the retail, service, office warehouse and industrial sectors. For buildings from 200 to 2000m 2. The air distribution can be carried out directly via the indoor unit or from a distance via a network of ducts. The solutions vary depending on : - the space available for the indoor unit : horizontal cabinet, vertical cabinet or ceiling installation, - the space available for the outdoor unit : floor installation, installation at a height or in an indoor space. FOR WHOM? FOR WHAT? TTA/TWA Light commercial applications (supermarkets, offices, warehouses...) Flexibility of our blower units Scroll technology on our axial fan condensing units Flexibility of installation TRANE S ADVICE Ideal units for existing duct networks thanks to its flexibility on airflow and static pressure. TWE Perfect alternative when you can not have a roof application LIGHT COMMERCIAL RANGE UN-PRC00-EN

5 TWE+TTA TWE+TWA TR Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes. Galvanised steel panels. Removable condensate drain pan. Throwaway filters as standard. Thermal protection of the fan motor winding. Expansion valve factory installed. Check valves for heat pump applications Expansion valve TTA/TWA outdoor units : cooling circuit (size 07 to 20). 2 cooling circuits (sizes 0 to 240). Scroll compressor(s). Internal thermal protection of the fan and compressor motor windings. Crankcase heater. Liquid line filter drier. Direct drive axial fan motor. Anti-recycle timer (compressor). Stop valves (gas and liquid) with brazed connections. Aluminium fin coil and copper tubes. Split System TTA/TWA Accessories : TWE indoor unit : Supplemental heaters: electric, hot water and steam. Low static drive kit. Oversized drive kit. TTA/TWA outdoor units : Low ambient speed controller (TTA only). Black epoxy fins. Control : 24 V electro-mechanical control. Digital display electronic wall thermostats. TAYSTAT 70, non programmable. BAYSTAT 038 programmable Remote sensor. TWE THERMOSTAT Maximum line lengths and diameters : See page 36. TTA/TWA Operating limits : TWE + TTA/TWA Cooling mode Heating mode Min. outdoor air temperature + C standard - C - C with speed controller Max. outdoor air temperature + 4 C + 20 C 6 UN-PRC00-EN

6 TWA General Data Heat Pumps - 60 Hz 7½ Ton 0 Ton Ton 20 Ton Single Compressor Single Compressor Dual Compressor Dual Compressor TWA090A3, A4, AW TWA20A3, A4, AW TWA80B3, B4, BW TWA240B3, B4, BW Cooling Performance Gross Cooling Capacity Matched Air Handler (MBH) Heat Pump Only 2 (MBH) ARI Net Cooling Capacity (MBH) EER 4 Matched Air Handler (MBH) Heat Pump Only 2 (MBH) System/Condensing Unit Poer (kw) 8.70/7.9.9/ / Heating Performance ARI Heating with Matched Air Handler High Temperature Capacity (MBH) System kw/cop 7.68/ / / /3. Low Temperature Capacity (MBH) System kw/cop Compressor No./Type /Trane 3-D Scroll /Trane 3-D Scroll 2/Trane 3-D Scroll 2/Trane 3-D Scroll Sound Rating (BELS) System Data 6 No. Refrigerant Circuits Suction Line (in.) OD Liquid Line (in.) OD Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter (in) Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM ,780 6,240 No. Motors/HP /.0 /.00 2/.0 2/.00 R-22 Refrigerant Charge (Field Supplied) (Lbs. of R-22) Notes: () Cooling Performance is rated at 9 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/ (2) Condensing Unit Only Gross Cooling Capacity rated at 4 F saturated suction temperature and at 9 F ambient. (3) ARI Net Cooling Capacity is calculated with matched blower coil and 2 ft. of 3, OD interconnecting tubing. (4) EER is rated at ARI conditions and in accordance with DOE test procedures. () Sound Rating shown is tested in accordance with ARI Standard 270 or 370. (6) Refer to refrigerant piping applications manual for line sizing and line length. (7) Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 2 ft. of interconnecting refrigerant lines. All units are supplied with a small nitrogen holding charge only. TWA General Data Heat Pumps - 0 Hz TWA07A TWA00A TWAB TWA200B Cooling Performance Gross Cooling Capacity Matched Air Handler, MBH (kw) 82 (23.97) 09 (3.97) 66 (48.7) 26 (63.24) Heat Pump Only 2, MBH (kw) 82 (23.97) 0 (30.7) 6 (47.04) 209 (6.8) ARI Net Cooling Capacity 3 80 (23.3) 0 (30.7) 60 (46.74) 96 (6.8) System Power kw Heat Pump Only Power kw Heating Performance ARI Heating with Matched Air Handler High Temperature Capacity, MBH (kw) 7 (2.82) 06 (3.0) (44.27) 206 (60.26) Low Temperature Capacity, MBH (kw) 47 (3.84) 69 (20.29) 9 (27.67) 3 (39.66) Compressor Number 2 2 Type 3D Scroll 3D Scroll 3D Scroll 3D Scroll ARI Sound Rating (BELS) System Data No. Refrigerant Circuits 2 2 Suction Line, in. (mm) OD.37 (34.9).37 (34.9).37 (34.9).37 (34.9) Liquid Line, in. (mm) OD 0.00 (2.7) 0.00 (2.7) 0.00 (2.7) 0.00 (2.7) Outdoor Fan Type Propeller Propeller Propeller/Propeller Propeller/Propeller No. Used 2 2 Diameter, in. (mm) (660.4) (7) (660.4/660.4) (7/7) Drive Type Direct Direct Direct/Direct Direct/Direct No. Speeds CFM 6, (m 3 /h) 4700 (798) 6700 (382) 9800 (6649) 3400 (22764) No. Motors 2 2 Motor HP (kw) 0.33 (.24) 0.7 (.6) 0.33 (.24) 0.7 (.6) R-22 Refrigerant Charge, lb 7 (kg) 8.0 (8.6) 24.2 (.0) 36.0 (6.32) 48. (22.0) Notes: () Cooling Performance is rated at 9 F (3 C) ambient, 80 F (26.7 C) entering dry bulb, 67 F (9.4 C) entering wet bulb and nominal cfm listed. ARI rating cfm is 30 cfm/ton for this product. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Rated accordance with ARI Standard 20. (2) Condensing Unit Only Gross Cooling Capacity rated at 4 F (7.6 C) saturated suction temperature and at 9 F (3 C) ambient. (3) ARI Net Cooling Capacity is calculated with matched blower coil and 2 ft (7.6 m) of.37, 0.00 OD interconnecting tubing. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. Integrated Part Load Value is based on ARI Standard 2040/340. Units are rated at 80 F (26.7 C) ambient, 80 F (26.7 C) entering dry bulb, and 67 F (9.4 C) entering wet bulb at ARI rated cfm. (4) ARI Sound Rating is rated in accordance with ARI Standard 270. () System Data based on maximum linear length 80 ft (26.7 m)maximum lift: suction 60 ft (8.3 m) liquid 60 ft (8.3 m) For greater lengths, refer to refrigerant piping applications manual. (6) Outdoor Fan cfm is rated with standard air-dry coil outdoor. (7) Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 2 ft (7.6 m) of interconnecting refrigerant lines. LIGHT COMMERCIAL RANGE UN-PRC00-EN 7

7 60 Hz Condensing Units 7½ Ton 0 Ton 0 Ton 0 To n 2½ Ton Ton Ton 20 Ton Compressors: Single Single Dual Manifolded Dual Dual Manifolded Dual Model: TTA 090A3, A4 20A3, A4 20B3, B4 20C3, C4 0B3, B4 80B3, B4 80C3, C4 240B3, B4 Cooling Performance Gross Cooling Capacity (MBH) Matched Air Handler Condensing Unit Only ARI Net Cooling Capacity EER 4 Matched Air Handler System KW/Condensing Unit kw 8.6/ /.2.89/0.94.9/. 4.70/ / / Compressor No./Make /3-D /3-D 2/Climatuff 2/Copeland 2/Climatuff 2/3-D 2/3-D 2/3-D Type Scroll Scroll Scroll Manifolded Scroll Scroll Manifolded Scroll Scroll Scroll No. Motors/HP /7.0 /0.00 2/.00 2/.00 2/6.2 2/7.0 2/7.0 2/0.00 Sound Rating (BELS) System Data 7 No. Refrigerant Circuits Suction Line (in.) OD Liquid Line (in.) OD ½ ½ 3 ½ 3 ½ ½ Outdoor Fan - Type Propeller Propeller Propeller Propeller Propeller Propeller Propeller Propeller No. Used/Diameter (in.) Cfm,670 8,20 8,20 8,20 8,20 0,900,340 6,20 No. Motors/HP /.0 /.00 /.00 /.00 /.00 2/.0 2/.0 2/.00 Refrigerant Charge (Field Supplied) (Lbs of R-22) Hz Condensing Units TTA07A TTA08A TTA00A TTA00B TTA00C TTA2B TTAB TTAC TTA200B Cooling Performance Gross Cooling Capacity Matched Air Handler (MBH) Condensing Unit Only 2 (MBH) ARI Net Cooling Capacity 3 (MBH) System Power kw Condensing Unit Power kw Compressor Number Type 3-D Scroll 3-D Scroll 3-D Scroll Climatuff Scroll TandemClimatuff 3-D Scroll3-D Scroll Tandem 3- D Scroll No. Speeds (each) No. Motors (each) Motor HP/kW 6.2/ / /6.2 4./3. 4.6/3.0.20/ / / /6.2 ARI Sound Rating (Bels) System Data No. Refrigerant Circuits Suction Line in./mm OD.37/ / / / / / /4.3.37/34.9 Liquid Line in./mm OD / / Outdoor Fan Type Propeller Propeller Propeller Propeller Propeller Propeller Propeller Propeller Propeller No. Used Diameter in./mm 26.00/ / / / / / / / /7.2 Drive Type Direct Direct Direct Direct Direct Direct Direct Direct Direct CFM 6 /m 3 /h 4700/ / / / / / / / No. Motors 2 Motor HP/kW 0.33/ /.6 0.7/.6 0.7/.) 0.7/.6 0.7/. 0.33/ / /.6 R-22 Refrigerant Charge, lb 7 /kg 3.0/ / / / / / /6.33) NOTES:. Cooling Performance is rated at 9 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360 or Condensing Unit Only Gross Cooling Capacity rated at 4 F saturated suction temperature and at 9 F ambient. 3. ARI Net Cooling Capacity is calculated with matched blower coil and 2 ft. of 3, OD interconnecting tubing. 4. EER is rated at ARI conditions and in accordance with DOE test procedures.. Integrated Part Load Value is based On ARI Standard 340/360 or Units are rated at 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at ARI rated cfm. 6. Sound Rating shown is tested in accordance with ARI Standard Refer to refrigerant piping applications manual for line sizing and line length. 8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 2 ft. of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only. 8 UN-PRC00-EN

8 General Data Air Handlers Ton 7½ Ton 0 Ton Single Circuit Dual Circuit Single Circuit Dual Circuit Single Circuit 060A, A3 060B, 090A, Model: TWE 00A A4, A B3, B4 07A A3, A 090B,B3 00A 20A 20A3 System Data No. Refrigerant Circuits 2 2 Suction Line (in.) OD 3/ Liquid Line (in.) OD 3 3 /6 3 Indoor Coil - Type Plate Fin Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Expansion Valve Drain Connection Size (in.) PVC PVC PVC PVC PVC PVC PVC PVC PVC Indoor Fan - Type Centrifugal No. Used/Diameter x Width (in.) x2 x2 x2 /x /x /x /x /x /x Drive Type/ No. Speeds Belt/Adjustable CFM No. Motors Motor HP - Standard/Oversized.7/.00.7/.00.7/.00.00/ / / Filters - Type/Furnished Throwaway/Yes Number Size Recommended 6x20x 6x20x 6x20x 6x2x 6x2x 6x2x 6x2x 6x2x 6x2x 20x20x 20x20x ARI tested and certified with various heat pumps in accordance with ARI Standard 2040 or 340/360 or certification program. Refer to Performance Data section in this catalog. NOTES:. Ships wired for /3/60. Field convertible to 460/3/ TWE060A has Motor RPM of 340 for oversized motor. 3. TWE20A does not have an oversized motor option. General Data Air Handlers (Continued) 0 Ton Ton 20 Ton Dual Circuit Dual Circuit Dual Circuit TWE20B3 TWE00B TWE20B TWEB TWE80B3, B4 TWE200B TWE240B3, B4 System Data No. Refrigerant Circuits Suction Line (in.) OD Liquid Line (in.) OD 3 3 Indoor Coil - Type Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Expansion Valve Expansion Valve Expanson Valve Expansion Valve Expansion Valve Expansion Valve Drain Connection Size (in.) PVC PVC PVC PVC PVC PVC Indoor Fan - Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal No. Used/Diameter x Width (in.) /x /x\ 2/x 2/x 2/x 2/x Drive Type/ No. Speeds Belt/Adjust Belt/Adjust Belt/Adjust Belt/Adjust Belt/Adjust Belt/Adjust CFM \ No. Motors Motor HP - Standard/Oversized 2.00/ 2.00/ / / /.00.00/7.0 Filters - Type/Furnished Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes (No.) Size Recommended (4) 6x2x (4) 6x2x (8) x20x2 (8) x20x2 (4) 6x2x2 (4) 6x2x2 (4) 6x20x2 (4) 6x20x2 ARI tested and certified with various heat pumps in accordance with ARI Standard 2040 or 340/360 or certification program. Refer to Performance Data section in this catalog. NOTES:. Ships wired for /3/60. Field convertible to 460/3/60. LIGHT COMMERCIAL RANGE UN-PRC00-EN 9

9 Z Z Y Y X X TTA/TWA TTA/TWA Z X Z Y X TWE TWE Y E D A B C Access required to open the door of the starter panel 60 UN-PRC00-EN

10 TTA/TWA Outdoor unit TTA 07 TWA 07 TTA 00 TWA 00 TTA 20 TWA 20 Dimensions indoor unit (X x Y x Z) (mm) 290 x 970 x x 09 x x 09 x 6 outdoor unit (X x Y x Z) (mm) 060 x 90 x x 90 x x 00 x 00 Weight indoor unit (kg) outdoor unit (kg) Duct connection (adaptation kit) (mm) 290 x 442 x x 27 x 602 Accessory Nb & Ø (mm) x 3 3 x x 400 TWE + TTA (Cooling only) Indoor unit TWE 20 TWE 0 TWE 240 TWE 240 TWE 20 TWE 0 TWE 240 TWE 240 Outdoor unit TTA 20 TTA 0 TTA 200 TTA 240 Dimensions indoor unit (X x Y x Z)(mm) 638 x 662 x x 732 x x 804 x x 662 x x732x x 804 x 824 outdoor unit (X x Y x Z) (mm) 260x00 x x 00 x x 79 x x 79 x 90 Weight indoor unit (kg) outdoor unit (kg) Duct connection (mm) 4. x x 3.7 Accessory (Nb) 2 TWE + TWA Indoor unit TWE 20 TWE 0 TWE 240 TWE 240 TWE 20 TWE 0 TWE 240 TWE 240 Outdoor unit TWA 20 TWA 0 TWA 200 TWA 240 Dimensions indoor unit (X x Y x Z)(mm) 638 x 662 x x 732 x x 804 x x 662 x x732x x 804 x 824 outdoor unit (X x Y x Z)(mm) 260 x 00 x x 00 x x 79 x x 79 x 90 Weight indoor unit (kg) outdoor unit (kg) Minimum clearance (mm) Outdoor unit A B C D E TTA TTA TTA TTA TTA TTA Outdoor unit A B C D E TWA TWA TWA TWA TWA TWA LIGHT COMMERCIAL RANGE UN-PRC00-EN 6

11 RAUC TR Features: Advanced design for greater efficiency, reliability and flexibility Trane 3-D scroll compressor Four system control options on 20 through 60-ton units and three system control options on 80 through 20-ton units, each using solid-state, factoryinstalled electronics Coil frost protection with the VAV system control option on the 20 through 60-ton units Remote EVP control option on 80 through 20-ton units Air-cooled condensing unit with axial fan RAUC 20-0 TONS (0 HZ) TONS (60 HZ) Cooling Power Supply Uncrated Approx. Capacity Volts/Phase/Hz Dimensions (in.) Weight Model No. MBh 0 Hz 60 Hz H W L (Lbs) RAUC C /3/ /3/60 XL /4 22 RAUC C RAUC C /4 824 Dual Circuited Units RAUC C /3/ /3/60 XL / RAUC C RAUC C RAUC C /3/ /3/60 PWS /4 7 4 / RAUC D /4 7 4 / RAUC D Based on 60 Hz operation 2 Available 460/3/60 XL 62 UN-PRC00-EN

12 LIGHT COMMERCIAL RANGE UN-PRC00-EN 63

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

Split System Cooling Units

Split System Cooling Units Split System Cooling Units Split System Cooling Units 7.5 to 20 Tons Air Handlers 7.5 to 20 Tons 50 Hz June 2006 Introduction Split System Cooling Units... Designed With Your Needs In Mind. The Trane reputation

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Product Catalog. Split System Air Conditioners Odyssey SSP-PRC023H-EN. Heat Pump Condenser 6 to 20 Tons 60 Hz Air Handler 5 to 20 Tons 60 Hz

Product Catalog. Split System Air Conditioners Odyssey SSP-PRC023H-EN. Heat Pump Condenser 6 to 20 Tons 60 Hz Air Handler 5 to 20 Tons 60 Hz Product Catalog Split System Air Conditioners Odyssey Heat Pump Condenser 6 to 20 Tons 60 Hz Air Handler 5 to 20 Tons 60 Hz January 2016 SSP-PRC023H-EN Introduction Wide network availability Flexible applications

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR COMBINATION HEATING AND COOLING ROOFTOP UNITS RKKB SERIES 7.5, 8.5, 10, 12.5 & 15 TON [26.4, 29.9, 35.2 44 & 52.8 kw] RKMB SERIES 7.5, 8.5, 10 & 12.5 TON [26.4, 29.9, 35.2

More information

TCD-TCH. Self-contained rooftop unit. VOYAGER I and II range TCD: Downflow discharge and intake TCH: Horizontal discharge and intake

TCD-TCH. Self-contained rooftop unit. VOYAGER I and II range TCD: Downflow discharge and intake TCH: Horizontal discharge and intake TCD-TCH 5-20 TR 50 Hz, 2.5-25 TR 60 Hz Single circuit unit : sizes 06 and 07, Dual circuit unit : sizes 00 to 200, D-Scroll compressor for sizes 25 to 250, Internal protection of winding for fans and compressor(s),

More information

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004 Packaged Heat Pumps Voyager 12½ to 20 Tons 60 Hz September 2004 PKGP-PRC001-EN Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Split System Cooling

Split System Cooling Split System Cooling Cooling Units 6 to 20 Ton - 60 Hz, R-410A Air Handlers 5 to 20 Ton - 60 Hz, R-410A September 2009 SS-PRC028-EN Introduction Trane s reputation for providing quality comfort solutions

More information

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018 Product Catalog Packaged Rooftop Air Conditioners Foundation Electric/Electric 15 22 Tons, 50 Hz May 2018 RT-PRC073B-EN Introduction Packaged Rooftop Air Conditioners Trademarks Through the years, Trane

More information

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017 Product Catalog Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz June 2017 RT-PRC079B-EN Introduction Packaged Rooftop Air Conditioners Copyright Through the years, Trane

More information

Packaged Cooling with Electric Heat Rooftop Units

Packaged Cooling with Electric Heat Rooftop Units Packaged Cooling with Electric Heat Rooftop Units Voyager 12½ - 25 Tons - 60 Hz October 2004 Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most

More information

Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units

Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units Service Facts Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units Model Numbers TSC036E3,4,W YSC036E3,4,W WSC036E3,4,W

More information

Packaged Heat Pumps. Precedent - R Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. November 2008

Packaged Heat Pumps. Precedent - R Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. November 2008 Packaged Heat Pumps Precedent - R-22 3-10 Tons 60 Hz Packaged Heat Pumps (WSC) November 2008 PKGP-PRC003-EN Introduction Packaged Heat Pumps Figure 1. Packaged Heat Pumps Through the years, Trane has designed

More information

Packaged Heat Pumps. Precedent Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. February 2007

Packaged Heat Pumps. Precedent Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. February 2007 Packaged Heat Pumps Precedent 3-10 Tons 60 Hz Packaged Heat Pumps (WSC) February 2007 PKGP-PRC003-EN Preface Introduction and Warnings and Cautions Packaged Heat Pumps Through the years, Trane has designed

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Packaged Cooling with Electric Heat Rooftop Units

Packaged Cooling with Electric Heat Rooftop Units Packaged Cooling with Electric Heat Rooftop Units Precedent 3-10 Tons 60 Hz August 2004 Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Unit Features & Benefits RQPM/RQRM Series

Unit Features & Benefits RQPM/RQRM Series 2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

Packaged Heat Pumps. Precedent - R-410A Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC013-EN. August 2009

Packaged Heat Pumps. Precedent - R-410A Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC013-EN. August 2009 Packaged Heat Pumps Precedent - R-410A 3-10 Tons 60 Hz Packaged Heat Pumps (WSC) August 2009 PKGP-PRC013-EN Introduction Packaged Heat Pumps Trane customers demand products that provide exceptional reliability,

More information

Packaged Rooftops. Voyager, R-410A. 12½ - 25 Tons 60 Hz. Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC028-EN.

Packaged Rooftops. Voyager, R-410A. 12½ - 25 Tons 60 Hz. Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC028-EN. Packaged Rooftops Voyager, R-410A 12½ - 25 Tons 60 Hz Packaged Cooling (TC*) Packaged Gas/Electric (YC*) September 2007 RT-PRC028-EN Introduction Packaged Rooftop Air Conditioners Through the years, Trane

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Product Catalog Split System Air Conditioners Odyssey

Product Catalog Split System Air Conditioners Odyssey Product Catalog Split System Air Conditioners Odyssey R-22 Dry Charge HeatPumpCondenser 7.5, 10, 15 and 20 Tons 60 Hz July 2018 SSP-PRC027H-EN Introduction Wide network availability Flexible applications

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

Packaged Gas/Electric Rooftop Units

Packaged Gas/Electric Rooftop Units Packaged Gas/Electric Rooftop Units Voyager 12½ 25 Tons 60 Hz October 2004 Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 3 to 5 Tons, 60Hz RT-PRC078C-EN.

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 3 to 5 Tons, 60Hz RT-PRC078C-EN. Product Catalog Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 3 to 5 Tons, 60Hz August 2017 RT-PRC078C-EN Introduction Packaged Rooftop Air Conditioners Copyright Through the years,

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

LIGHT COMMERCIAL RANGE

LIGHT COMMERCIAL RANGE 64 ROOFTOP UNITS FROM 1.5 TO 50 TR Trane is a worldwide leader in the manufacture of rooftop units (600 units per day) Rooftop units are evidently the cheapest solution for large surface areas : above

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data 2TTB0030-060A 2½ 5 Tons 22-1739-04 General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems represent a product that is

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Packaged Cooling 20 Ton Rooftop Units with ReliaTel Controls, 50 Hz

Packaged Cooling 20 Ton Rooftop Units with ReliaTel Controls, 50 Hz Service Facts Packaged Cooling 20 Ton Rooftop Units with ReliaTel Controls, 50 Hz Models: TC*200FD YC*200FD SAFETY WARNING Only qualified personnel should install and service the equipment. The installation,

More information

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 15 to 25 Tons, 60 Hz RT-PRC060H-EN.

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 15 to 25 Tons, 60 Hz RT-PRC060H-EN. Product Catalog Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 15 to 25 Tons, 60 Hz May 2017 RT-PRC060H-EN Introduction Packaged Rooftop Air Conditioners Through the years, Trane

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A Product Data 22178001 2/4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ 5 Ton R22/R410A 2/4YCX3018A through 2/4YCX3060A Mar. 03, 2006 2006 American Standard inc. All Rights

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Ruud Commercial Achiever Series Package Gas Electric Unit featuring HumidiDry Technology

Ruud Commercial Achiever Series Package Gas Electric Unit featuring HumidiDry Technology Package Gas Electric Ruud Commercial Achiever Series Package Gas Electric Unit featuring HumidiDry Technology RKNL-G 13 SEER Series With ClearControl Nominal Sizes 3-5 Tons [10.6-17.6 kw] SINGLE PHASE

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PACKAGE HEAT PUMPS FEATURING EARTH-FRIENDLY R410 REFRIGERANT RJNL-B/RJNL-C SERIES 7.5 & 10 TON 60 Hz MODELS!! Recognize this symbol as an indication of Important Safety Information!

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Split System Condensing Units and Remote Chillers

Split System Condensing Units and Remote Chillers Split System Condensing Units and Remote Chillers 20 to 120 Tons 50 and 60 Hz November 2001 Introduction Trane 20 through 120-ton air-cooled condensing units are the leaders in the split system marketplace.

More information

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG: Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Packaged Cooling & Gas/Electric Rooftops. Voyager. 12½-25 Tons 60 Hz. Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC024-EN.

Packaged Cooling & Gas/Electric Rooftops. Voyager. 12½-25 Tons 60 Hz. Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC024-EN. Packaged Cooling & Gas/Electric Rooftops Voyager 12½-25 Tons 60 Hz Packaged Cooling (TC*) Packaged Gas/Electric (YC*) December 2006 RT-PRC024-EN Introduction Packaged Rooftop Air Conditioners Through the

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF:

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PACKAGE AIR CONDITIONERS RSNM/RSPM SERIES (2.0-5.0 TONS) FEATURING NEW INDUSTRY STANDARD R-410A REFRIGERANT:!! WARNING THESE INSTRUCTIONS ARE INENDED AS AN AID TO QUALIFIED, LICENSED

More information

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4 Product catalog Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4 Features and Benefits Outdoor unit 4TTB Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Package Air Conditioners Featuring Industry Standard R-40A Refrigerant RLNL 3 SEER (3-5 TONS) SERIES RLPL 4 SEER (3-5 TONS) SERIES (4 SEER ONLY) ISO 900:2008 ISO 900:2000 [ ]

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17

More information

Illusion Split System

Illusion Split System Illusion Split System 50 Hz/R410A Range:1-5 Tons Indoor Units MCDA18DB MCDA24DB MCDA30DB MCDA36DB MCDB42DB MCDB48DB MCDB60DB Outdoor Units 4TTB3018AA 4TTB3024AA 4TTB3030AA 4TTB3036AA 4TTA3030AD 4TTA3036AD

More information

T P A 120 S 4 S N 1 Y

T P A 120 S 4 S N 1 Y PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Split System Cooling Product Data XB 1000

Split System Cooling Product Data XB 1000 Split System Cooling Product TTB-D-7 XB 1000 TTB012-060C PUB. NO. 22-1689-02-797 (EN) General Features Split System Cooling Units... Designed With Your Needs In Mind. TTB Split systems represent a new

More information

Product Catalog. Packaged Rooftop Air Conditioners Voyager Heat Pump 12½ 20 Tons 60 Hz PKGP-PRC012-EN. August 2013

Product Catalog. Packaged Rooftop Air Conditioners Voyager Heat Pump 12½ 20 Tons 60 Hz PKGP-PRC012-EN. August 2013 Product Catalog Packaged Rooftop Air Conditioners Voyager Heat Pump 12½ 20 Tons 60 Hz August 2013 PKGP-PRC012-EN Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

Split System Condensing Units and Remote Chillers

Split System Condensing Units and Remote Chillers Split System Condensing Units and Remote Chillers 20 to 120 Tons 50 and 60 Hz June 2008 Introduction Trane 20 to 120-ton air-cooled condensing units are the leaders in the split system marketplace. Designed

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application 6.2-30 tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application High-performance, energy-saving, cost-effective rooftop air conditioning solutions for your business

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information