Our. Heaters. for your Projects
|
|
- Bryan Long
- 5 years ago
- Views:
Transcription
1 P RO D U C T I N FO C U S Our Heaters for your Projects H E at t r a c i n G s Y s t E M s H E at E r s s U r Fa c E H E at i n G s Y s t E M s boilers
2 2 Electric Heaters Electric heaters are used for direct (rarely) indirect heating or temperature maintenance (compensation of heat losses), vaporization and melting of solid, liquid and gaseous media. The System at a Glance For the worldwide use of our products and services we are fulfilling the high quality demands and expectations of our customers from design up to commissioning. Not only to keep these demands but to develop them continuously to the benefit of our customers. This is reached by our integrated management system and the clearly defined company. Each of our employees is involved in the management system and is responsible for the quality of our products and services. Quality right from the Start The specialists for electric heating systems
3 H E ate rs 3 ElE ctric HE ate rs Our scope of supply it passes from heating inserts up to the complete unit for the installation in the ex-threatened area. All our electrical heating systems are tailored to your needs. These include complementary components like condensate, collective container and balance container, water treatment, pump as well as armatures belong to it. The power supply is steered by a switch arrangement and control. Our Management system IECEx Quality Assessment Report Quality Management System according to DIN EN ISO 9001 Safety Management according to SCC**-Catalogue Ex-Directive 94/9/EC (ATEX) Pressure Equipment Directive according to DgRI 97/23/EC AD 2000 HP0 ASME U-Stamp
4 4 application The Application Range for heating inserts and heaters include among others the chemical, petrochemical, pharmaceutical, steel, textile, cellulose, oil and gas industries as well as power stations and refineries. The Erection can take place both, in non-explosive and explosion-endangered areas of zones 1 and 2 in the presence of gases and vapors of groups IIa, IIB and IIc. For use in explosion-endangered areas, the standard heating insert is delivered with a connection box in flameproof enclosure, design Ex d, if required, with additional connection boxes increased safety Ex e or Ex i intrinsically safty, including Ec type examination certificate/ec declaration of conformity certificate, thereby the electrical part is separated from the instrumentation part. To keep the temperature class defined by the operator for the place operation by cooling sections and additional thermal protection measures are part of our design and have to be verified at site. The Design for an electric heater depends on the temperature required, the pressure and the connection power. The material is selected according to the medium to be heated, the temperature and pressure. materials such as carbon steel, stainless and heat resistant steels, nickel-based alloys, titanium and other surface-coated special materials are used. The limits of application need to be verified in each individual case. The following operating and design conditions have already been proved to be feasible: > temperatures up to 650 C, with special constructions up to 850 C > pressures up to 250 bar > power inputs of up to kw can be reached in one unit so far, however not presenting our maximum power limit > connection voltages up to 690 V, in special cases up to 1200 V The specialists for electric heating systems
5 H E ate rs 5 a pplicatio n c O nstru ctio n construction An electric heater is comparable with a conventional tube bundle heat exchanger and consists of the following components: > cylindrical shell (flow pipe) with nozzles for medium inlet and outlet and, as required, with nozzles for drain, ventilation, safety valve etc. > heating insert (tube bundle) with electric heating elements (the medium inside the pipe is replaced by electric energy) > girth flange for fixing the heating insert > temperature sensor (limiter) for measuring the heating surface temperature > temperature sensor (controller) for measuring the medium temperature > supports for horizontal or vertical erection > wiring room (pre-chamber) of heating insert > connection box for temperature sensors The medium is heated during the flow. The flow is directed in one or several ways, transversely or longitudinally, depending on the medium and the operating conditions. The maximum temperature permitted on the heating surface (specified by the medium to be heated and the material selection) and the pressure loss permitted need to be taken into consideration. The temperature of heating surface is monitored by at least two temperature sensors (thermocouple, PT100, thermostat), functioning as limiters. as soon as the temperature permitted is reached, the total power of the heater is switched off. A restart can only be effected after having clarified the reason for cut-off.
6 6 construction Different types of heating elements are used for the transmission of heat, such as hairpin heating elements and ceramic heating elements. Hairpin heating elements The standard hairpin heating elements consist of a metal jacket pipe with a diameter of 8.5 to 16 mm, bended U-shaped. The heating wire is located in the centre of the pipe, embedded in highly compressed magnesium oxide. This guarantees an excellent isolation resistance and a perfect heat conductivity between heating conductor and jacket pipe. The elements are installed into the tube sheet of heating insert by brazing, welding or screw connections. The hairpin heating elements are mainly used for heating up gases and liquids. Ceramic Heating Elements mainly consist of ceramic parts, pushed and fixed onto a guide rod and the heating spiral. The ceramic heating elements are pushed into a metallic heating cartridge tube. The cartridge tube is sealed to avoid direct medium contact and welded pressure-tightly into the tube sheet. The elements can be exchanged without interrupting operation. They are predominantly used for heating fuel oils, thermal oils or other highly viscose fluids. The specialists for electric heating systems
7 H E ate rs 7 constru ctio n DEsiG n Design The installed power depends on the process requirements. also several operating conditions can be realized with one electric heater. The thermal design of electric heater needs to be calculated in such a way that the medium can absorb the energy supplied without exceeding the temperature permitted on the heating surface. The know how is based on the capability to distribute the power over a surface in a technically and economically optimum solution. Concentrating the power over a small surface produces a high watt density (W/cm ) and thus a higher temperature on the heating surface. In the most unfavorable case this might lead to a damage of medium or damage of heating elements. In comparison, a conventional heat exchanger needs to have sufficient exchange surface available to be able to supply the energy to the medium to be heated. The mechanical design of components under pressure is calculated in accordance with harmonized norms such as Pressure Equipment Directive En 13445, En 12993, on request, by using the respective calculation rules in the country of installation or other international standards e.g. asme including all necessary tests, certificates and inspections. additionally required conditions such as consideration of nozzle loads by connected pipelines, supports and wind loads and seismic safety also belong to the design standard.
8 8 switch and control cabinets Regulation, Control For all electric heaters, we design and delivery switchboard and control panels for erection in distribution stations or outdoor, here also in hazardous areas. The power is controlled by a signal of 4-20 ma, provided by the customer, either via several heating stages or infinitely variable via thyristor controller. The latter normally disposes of an undercurrent control and/or a 4-20 ma signal for external power indication and are operated in two or three phases in full-wave mode. Before delivery, a general function test is performed, a full current test is feasible as well. The specialists for electric heating systems
9 H E ate rs 9 s witch and control c abinets KOnstrUKtiO r EFErEncEns practice examples The below-mentioned major projects only present a small selection of all our projects realized. Please contact us if you require additional information. 2x2 Gas heaters The double deck gas heaters were design to heat up big gas amounts, in a refinery in the explosion-threatened area. Because of the high pressure and temperature the challenge was to distribute the achievement on the surface which proves the optimum solution technically and economically. Technical Characteristics: > heating capacity 4x = 850KW 3400KW > maximum temperature: 450 c > Design pressure: bar > Supply voltage: max. 690 V / ac Manufacturing Standard > PED 97/23 / Ec > asme VIII Div 1- The range of application: > heating of gas in the hazardous area The functional principle Continuous heating of the medium by heat exchange between pipe and radiator medium. Our know-how is in the heat exchange area and optimally adapted to the individual operating conditions adapt to Ensure that the process temperature reaches is permissible without heating surface or the permissible pressure drop is exceeded.
10 10 Hot water boiler type series HWE The hot water boiler are suited as consumers for mains stabilisation, as autonomous calorifiers without local emission sources, and as a means to secure the district heating supply. your advantage: The hot water boiler can be directly integrated into the district heating mains. The area of application comprises all control range products: Secondary control range (SRl), minute reserve (mrl). Technical Characteristics: > Power range: 1 to 5 mw > Electrical connection: 690 V/50 hz/3 ph > calculation pressure: up to 30 bar > calculation temperature: up to 230 c Manufacturing Standards: > Pressure Equipment Directive (PED) 97/23/Ec > En / En / ad-2000 Your advantages: > Stepless power control at high power levels in combination / Infinitely > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality > Direct connection to the district heating network > no heat exchanger required > Supervision-free operation: according to En12953 (TRD 604) available (72 hours control interval) (BoB 72) > high redundancy by up to 250 single heating elements > Sturdy and maintenance-free design The specialists for electric heating systems
11 Heaters 11 REFERENCES SERVICE Take us for granted. Gladly at any Time. Apart from careful planning and manufacturing, a professional installation is essential for the proper function of a heating system. Our skilled and qualified assembly team offers you this service. Our employees install, test and put our heating systems including respective control units into operation. The quality of our work is guaranteed by regular training measures and the application of our management system and the SCC** catalogue (safety, health and environment). A continuous maintenance of our heating systems and a detailed technical documentation complete our service package. SERVICE PROMISES
12 KTPR02.En KLÖPPER-THERM GmbH & Co. KG Unterste-Wilms-Straße Dortmund Germany P.O. Box Dortmund Germany / I / sales@kloepper-therm.de The specialists for electric heating systems
Explosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY
ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage
More informationELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY
ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage
More informationIndustrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version
heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology
More informationFlange immersion heaters
Flange immersion heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE CETAL flange immersion heaters are designed and manufactured
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationOperating instructions
Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen
More informationPESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard
Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive
More informationHEAT. Industrial Ltd. Standard Products
HEAT Industrial Ltd Standard Products EXHEAT Standard Products EXHEAT Industrial Division offers fast track solutions to industry's wide and varied requirements for electrical heating systems. All heaters
More informationSeat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.
ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationIndustrielle Elektrowärme GmbH. OhmEx. Company Presentation. Dipl.-Ing. Wolfgang Vogler (GM)
Company Presentation Dipl.-Ing. Wolfgang Vogler (GM) 1 Main Competence is recognised as a professional and competitive company in design and manufacture of electric process heaters and assosiated thyristor
More informationHeat exchangers in Thermo Plate-design Type XPT. + variable + cleanable + efficient + safe FULLY WELDED
Heat exchangers in Thermo Plate-design Type XPT + variable + cleanable + efficient + safe FULLY WELDED The XPT for use in a wide range of applications + The pillow-shaped design of the Thermoplates permits
More informationL+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4
Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors
More informationHeated tools. Semiconductor equipment
Heated tools Semiconductor equipment Ceramic heating elements made of silicon nitride and aluminum nitride can be manufactured as tools in various shapes. The heating function can be integrated in complex
More informationScrew plug immersion heaters
Screw plug HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE The screw plug by CETAL are designed and manufactured as a standard range or according to customer specifications. Reliability
More informationNuclear Electric Heating
Nuclear Electric Heating Caloritech has exceeded the most demanding nuclear heating requirements for over 30 years. We design and manufacture products for nuclear applications in PWR, BWR and PHWR nuclear
More informationATEX, NOMENCLATURE AND CODING
Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are
More informationAgency Certifications, Recognition and Approvals
Agency Certifications, Recognition and Approvals WATROD and FIREBAR Element and Assemblies...559 Agency Certifications, Recognition and Approvals 557 558 WATROD and FIREBAR Element and Assemblies Agency
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationSection 4. ThermalEx - Certified Hazardous Area Heaters
Section 4 ThermalEx - Certified Hazardous Area Heaters Page What is the IECEx Scheme? 4.1 What is the ATEX Directive? 4.1 ThermalEx Explosionproof Heaters 4.2 Applications and Options 4.3 ThermalEx End
More informationFlanged Immersion Heaters
Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationFlanged Immersion Heaters
Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationImmersion Heaters. Screw Plug Immersion Heater
Screw plug immersion heaters are ideal for direct immersion heating of liquids, including all types of oils and heat transfer solutions. Available in a variety of sizes, screw plug immersion heaters feature
More informationFlanged Immersion Heaters
Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating
More informationAgency Certifications, Recognition and Approvals
Agency Certifications, Recognition and Approvals WATROD and FIREBAR Element...563 Agency Certifications, Recognition and Approvals WATLOW 561 562 WATLOW WATROD and FIREBAR Element Agency Recognition UL
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationATEX, NOMENCLATURE AND CODING
ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as
More informationTHERMAL ELECTRIC ELEMENTS
certified hazardous area heaters VERSION 1.1 THERMAL ELECTRIC ELEMENTS AUSTRALIA THE SPECIALISTS IN CUSTOM HEATING about tee Thermal Electric Elements was established in 1972 as a father and son operation
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationExplosion-protected actuator Page 259 of 292
Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationGENERAL OVERVIEW ELECTRIC HEATERS - EXCHANGERS - PACKAGES ELECTRIC HEATING SOLUTIONS ELECTRIC HEATERS EXCHANGERS PACKAGES
GENERAL OVERVIEW ELECTRIC HEATERS - EXCHANGERS - PACKAGES ELECTRIC HEATING SOLUTIONS ELECTRIC HEATERS EXCHANGERS PACKAGES COMPANY PROFILE Masterwatt is specialized in the production of electric heaters
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationQuality Heat Exchangers
Quality Heat Exchangers Brazed Plate Heat Exchangers Series TPL With partnership into the future FUNKE is a leader in the development and production of quality heat exchangers with a heat transfer area
More informationIntrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20
Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical
More informationQuality Heat Exchangers
Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of
More informationGENERAL SPECIFICATION ELECTRICAL
GENERAL SPECIFICATION ELECTRICAL GS ELE 331 Tape trace heating 00 10/04 First issue Rev. Date Notes Contents 1. Scope...3 2. Reference documents...3 3. Environmental Conditions...4 4. Technical Requirements...5
More informationEUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU
EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific
More informationPackaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase
Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free
More informationSeptember 2012 EGO Tubular Heating Elements - Technical Details page 1 of 12
EGO Tubular Heating Elements - Technical Details Table of contents 1) Structure of the Heating Element / types 2) Configuration of Tubular Heating Elements 3) Thermal fuse 4) Connections 5) Shape of the
More informationC D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product
Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is immediately
More informationThe R. STAHL Technology Group Worldwide Success with Competence and Customer Support
The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationELECTRIC HEATING. we get to the point... Gräff GmbH Bonner Strasse 54 D Troisdorf Tel: +49(0) Fax: +49(0) ISOMA
ELECTRIC HEATING ELECTRIC HEATING ISOMA ~ we get to the point... Gräff GmbH Bonner Strasse 54 D - 53842 Troisdorf Tel: +49(0)2241-4907-0 Fax: +49(0)2241-4907-77 Internet: http://www.graeff-gmbh.com E-Mail:
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationTubular Industrial Process
are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating type heaters, to a pipe. See
More informationINSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS
INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.
More informationAdvanced heat transfer technology
Advanced heat transfer technology Providing substantial energy savings through customized designs Thermo plate products for the process industry Thermo plate products for the process industry Unique transfer
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationSpiral heat exchangers
Spiral heat exchangers www.tranter.com, www.spiralheatexchangers.com Tranter HES GmbH Tranter HES originated from the acquisition of HES GmbH Heat Exchanger Systems GmbH early 2009. Tranter HES represents
More informationAM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74
AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationEXHEAT Industrial Standard Products
Standard Products EXHEAT Industrial Standard Products EXHEAT Industrial offers fast track solutions to the industry s wide and varied requirements for electrical heating systems. All our heaters are manufactured
More informationQuality Heat Exchangers
Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of
More informationSafe area; Zone 1 and Zone 2
6 6/0 Instrumentation Systems 6 Instrumentation Equipment Technology Control cabinets and system components for all aspects of instrumentation for installation in the control room Field stations with I.S.
More informationDual certification! Air handling units for potentially explosive atmospheres
Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to
More informationHEATING. Hazardous Area. custom engineered heating solutions
HEATING Hazardous Area custom engineered heating solutions Hazardous Area Heating Hazardous Areas Many industries, ranging from off shore oil platforms, on site heavy fuel oil tank farms, food and beverage,
More informationSafety instructions VEGAPULS 64
Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection
More informationManual Isolating Barrier D461R1 (Revision 01)
D461R1 Manual Isolating Barrier D461R1 (Revision 01) Product Manual Original Instructions valid for models D461R1.11 with 1x signal input into 1x isolated signal output D461R1.12 with 1x signal input into
More informationDocumentation. Parallel Heating Cable. Type: ELP
Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant
More informationCast Line Heaters The Benefits of This Space Saving Electric Heater
WHITE PAPER Cast Line Heaters The Benefits of This Space Saving Electric Heater Introduction Cast line heaters, or cast-in heaters, offer an alternative to the more common inline process heaters that have
More informationOperating Instructions for Rotor flow Indicator. Model: DKF
Operating Instructions for Rotor flow Indicator Model: DKF 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Mechanical Connection... 4 5.1 Before installation...
More informationASME Packaged Electric Water Heater
MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long
More informationS&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.
S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design. STUDY NOTES Instructor: Javier Tirenti training@arvengconsulting.com www.arvengconsulting.com Table of contents
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating
More informationPIROWATT - High Power Cartridge Heaters -
PIROWATT - High Power Cartridge Heaters - Figure 1 GENERAL CHARACTERISTICS These heaters are characterised by a high specific power and a high reliability: These qualities are essential in the applications
More informationCOMPACT FLAME CONTROLLER CFC 1000
COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More information// Explosion Isolation. No matter what happens - nothing happens. /
. No matter what happens - nothing happens. / Valve VENTEX Slide Valve RSV Flap Valve REDEX Flap Slide Valve REDEX Slide Confidence through safety: RICO Sicherheitstechnik AG. / The RICO quality promise.
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationRADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION
Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification
More informationDräger X-am 5000 Multi-Gas Detection
Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures
More informationErhitzer_engl_3:Wärmeträger :43 Uhr Seite 1. INTEC Engineering GmbH Thermal oil heaters
Erhitzer_engl_3:Wärmeträger-2 18.05.2011 9:43 Uhr Seite 1 INTEC Engineering GmbH Thermal oil heaters Erhitzer_engl_3:Wärmeträger-2 18.05.2011 9:43 Uhr Seite 2 Thermal Oil Heaters Thermal oil heaters by
More informationHEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES
STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES INTRODUCTION The HRSFUNKE Storage Calorifiers offer a high quality solution for domestic hot water (DHW) heating. The standard range is manufactured from
More informationMULTICELL... for HIGH-TEMP TUBULAR HEATER TYPICAL CARTRIDGE HEATER WATLOW MULTICELL HEATER TYPICAL TUBULAR HEATER
MULTICELL.................... Heaters...... Unique Advantages.. for Demanding Operations Sheath Temperature MULTICELL Heaters: the High Temperature Choice 2050 F (1120 C) WATLOW MULTICELL HEATER 1800 F
More informationCombi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610
Combi Modular System Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 SPX FLOW Johnson Pump brand water, chemical and petrochemical standardised pumps represent a range of centrifugal pumps
More informationMechanical Vacuum Systems for Secondary Metallurgy Steel Degassing
Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing 173.13.02 Utmost Efficiency VD / VOD processes Vacuum Degassing (VD) for low alloy steels; Vacuum Oxygen Decarburising (VOD) for stainless
More informationTop performance when the going gets tough
Top performance when the going gets tough The Alfa Laval DuroShell plate-and-shell heat exchanger Sub-headline coming soon DuroShell plate-and-shell made tougher Alfa Laval DuroShell is a specially engineered
More informationSondex - A World of Heat Exchangers For All Applications
Sondex - A World of Heat Exchangers For All Applications SONDEX HEAD OFFICE Sondex - A Leading Manufacturer of Plate Heat Exchangers Sondex A/S, a Danish company, was founded in 1984 by Mr. Aa. Søndergaard
More informationHeating Mats and Jackets. innovations in heat tracing
Heating Mats and Jackets innovations in heat tracing The eltherm GmbH Solutions with electrical heat tracing systems eltherm GmbH is an international operating company specialising in the field of electrical
More informationMANUAL Oil Level Sensor
PROCESS AUTOMATION MANUAL Oil Level Sensor KVF-104-PF ISO9001 0102 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products
More informationIntrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and
More informationSCREW PLUG IMMERSION HEATERS
SCREW PLUG IMMERSION HEATERS ELECTRIC PROCESS HEATER SOLUTIONS BEGIN HERE... Electric heaters are our only business. We are specialists in designing, engineering, and manufacturing both standard and custom
More informationINTEC Engineering GmbH Energy systems
INTEC Engineering GmbH Energy systems INTEC Engineering GmbH is an international company successfully operating in the design, delivery, installation and commissioning of energy systems. INTEC has established
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC
Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationSpandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products
Spandau Pumps Overwiev of Products 1-6000-US Sealless Immersion Pumps for Industrial Applications Centrifugal and screw pumps for low-, medium- and high-pressure applications Quality Management DIN EN
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More information