Installation & User s Instructions

Size: px
Start display at page:

Download "Installation & User s Instructions"

Transcription

1 Installation & User s Instructions shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer & Room Sensor Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. c Baxi Heating UK Ltd 0 B

2 .0 Contents Page.0 Contents.0 Introduction.0 Programmer & Room Sensor Functions.0 Installation & Wiring.0 Wireless Room Unit.0 Manual Synchronization 8 of Wireless Units.0 Standby & Operating Mode 8.0 Central Heating & Domestic Hot 0 Water activation.0 Temperature Settings 0.0 Setting the Time & Day.0 Setting Central Heating & Domestic Hot Water.0 Programmer & Room Sensor Parameter Codes.0 Error Codes Kit contents Programmer & Room Sensor - day Wired Programmer & Room Sensor - day Wireless Programmer & Room Sensor - hr Wireless Receiver Batteries (AA/LR) Fixing Screws Rawlplugs Instructions Table. Kit contents c Baxi Heating UK Ltd 0

3 8 8.0 Introduction 8. General Introduction. Specification of Units. 00 day Wired (for use with Neta-tec & Duo-tec) is wired directly to your boiler unit (Fig. ). 080 Day Wireless & 00 h Wireless (for use with Neta-tec, Duo-tec & Megaflo Compact) are operated remotely via radio frequency wireless transmission to a Radio Frequency Receiver fitted close to the boiler unit (Fig. ). Fig. Programmer & Room Sensor (080 shown). The sensor constantly monitors the temperature of the room in which it is installed. It can be operated in four temperature modes, Hi (or COMFORT ), Lo (or REDUCED ), Frost Protection, or left in Automatic () to operate as programmed.. Depending on the settings, the boiler will run the Hi COMFORT settings during a heating demand and the Lo REDUCED setting for overnight periods or times when the property is left unoccupied.. Wireless versions (080 & 00). The units require AA type alkaline batteries (Supplied). Installation of the batteries is shown in Fig... If the battery symbol is seen flashing in the digital display (Fig. ) the batteries need replacing. See Fig. for details. Fig. Receiver NOTE: If the batteries are left flat the unit will only retain its settings for a maximum of one week.. The batteries have a lifespan of approximately years. Batteries should be changed within this timescale as a precaution. Boiler Unit NOTE: If the batteries are flat the boiler will return to a default setting of Boiler ON.. The Clock Function will need to be checked every time the batteries are replaced. Fig. Programmer & Room Sensor - Wired version. Technical Specifications Insulation Class II IPX Rating IP Operating Temperature - to 0 Receiver Boiler Unit Transmission Frequency 88MHz (Wireless only) Fig. Programmer & Room Sensor - Wireless version c Baxi Heating UK Ltd 0

4 .0 Programmer & Room Sensor Functions. Description of Functions STANDBY Manual Mode Automatic Mode COMFORT Mode REDUCED Mode Domestic Hot Water Central Heating Communication (Wireless only) Mode Button 8 Programme and Time Segments Current Day ( = Monday) ( day version only) Current Time Measured Temperature Battery life (Replace if flashing) Burner ON Indicator Menu Button Selector Button Fig. Programmer & Room Sensor front view with functions Symbol Meaning Symbol Meaning Symbol Meaning Press the Button Day of the week = MON ( day only) Domestic Hot Water (flashing = selected) Press the Button Day of the week selected ( day only) Signal Strength (flashing = no signal) Rotate the Selector Button Standby selected Boiler runs using User defined times Press the Selector Button Central Heating (flashing = selected) Boiler in REDUCED Mode Time (flashing = selected) Temperature (flashing = selected) Boiler in COMFORT Mode Table Programmer & Room Sensor symbols & meanings c Baxi Heating UK Ltd 0

5 Programmer & Room Sensor Backplate IMPORTANT! When fitting Low Voltage Controls remove the Yellow Link Wire from the Boiler Terminal Block M Boiler Wiring Terminal M Low Voltage Terminal Block Boiler Mains Voltage Terminal Block M.0 Installation & Wiring. Installation 00 day Wired. This Programmer & Room Sensor will take full control of the boiler once fitted. All the boiler functions are transferred to the Programmer & Room Sensor except Chimney, Commissioning and the Combustion Adjustment functions (Refer to the Boiler Instruction Manual).. The boiler must be fully commissioned before fitting this Programmer & Room Sensor. NOTE: Communication between the boiler and the Programmer & Room Sensor can take up to minutes to establish. During this time, the boiler may attempt to fire prior to communication being established.. If necessary, control can be transferred back to the boiler. Either remove the unit from its cradle, or remove the plug from the Receiver, then turn the power to the boiler off and back on. Fig. Wiring details for day Wired 00 Rear Tab. Connecting 00 day Wired NOTE: The yellow link wire across terminals & on the Boiler terminal block M must be removed when fitting this Low Voltage control system. Fig.. Fig. Connector Pins. Power down the boiler.. Remove the backplate from the unit by pressing down on the rear tab and easing apart. Fig... Identify a suitable site to locate the Programmer & Room Sensor. See Fig. 8 for guidance on where to locate the unit.. Use a suitable grade of wire when connecting the Programmer & Room Sensor to the boiler. A specification of x 0.mm with a maximum length of 0m should be used.. Pass the wires through the access slots in the backplate and wire the terminals as shown in Fig... Screw the backplate to the wall using the fixings provided and reattach the Programmer & Room Sensor.. Turn the power back on. Min. 00 mm X 00mm X Fig. 8. Location positions c Baxi Heating UK Ltd 0

6 OT OT Fig.. Receiver Backplate IMPORTANT! When fitting Low Voltage Controls remove the Yellow Link Wire from the Boiler Terminal Block M. Press Securing Tab. Boiler Wiring Terminal M Low Voltage Terminal Block Boiler Mains Voltage Terminal Block M.0 Installation & Wiring (cont.). Connecting 080 day Wireless & 00 h Wireless. NOTE: The yellow link wire across terminals & on the Boiler terminal block M must be removed when fitting this Low Voltage control system. Fig... The Receiver should be wired to the boiler as shown in Fig.. Turn the power to the boiler off.. Remove the Receiver backplate by carefully prising it away from the body. Fig. 0.. Route the wires through the rear of the backplate panel. If a surface mount is required it will be necessary to break off the appropriate tabs to give the wire access.. Connect the wires to the OT connection on the terminal block. Fig.. Note this is removable for ease of wiring.. Connect the other end of the wire to the terminals on the boiler. Please refer to the boiler manual for wiring details.. Fix the Receiver to the wall using the fixings provided and refit the front cover ensuring the correct orientation. Fig. 8. Fit the batteries to the Programmer & Room Sensor. Fig.. Ease Backplate away. Fig 0. Receiver & Access Tab. Press Securing Tab. Fig. Completed Receiver. Ease away from Backplate. x AA/LR Batteries (Supplied) Fig.. Accessing batteries c Baxi Heating UK Ltd 0

7 Wireless Room Unit. Boiler & Programmer Communication C B A Example A: floor + walls. Example B: floors + wall. Example C: floors + no walls.. The units are pre-synced so should communicate with each other when powered up. NOTE: Communication between the boiler and the Programmer & Room Sensor can take up to minutes to establish. During this time, the boiler may attempt to fire prior to communication being established.. If Error codes 8 or 8 are seen during commissioning, there is a communication problem. Fig. Maximum permitted separation. Error 8 is due to the Receiver not communicating with the boiler. Check the wiring between the Receiver and boiler. Fig. X Error 8 Fig. Remote unit Error Codes Receiver Error 8 Boiler Unit. Error 8 is due to the Programmer & Room Sensor not communicating with the Receiver. The Programmer & Room Sensor is either out of range or has not synchronized correctly. Check the unit s location (Fig ) or proceed to the Manual Sync process in Section.0. If Error 8 is seen after commissioning, check: a) The Programmer and Room Sensor and the Receiver are within range of each other. See Fig. and Section. b) The units are synchronized correctly. Section.. c) The wiring is correct between the Receiver and boiler. Fig. HC. The maximum distance between the Receiver and the Programmer & Room Sensor will depend on the layout of the house. For a typical house, a guideline of floors or walls can be used, as shown in Fig. Hold for seconds. Test for Signal Strength tst tst Before mounting the Programmer & Room Sensor to the wall, perform the following test to determine the signal strength. Fig.. Press and hold the Selector Button for approximately seconds and HC will be seen in the display.. Rotate the Selector Button until tst is seen in the display. Up to 8 minutes test tst ON result 0 No Signal Weak Signal Poor Signal Good Signal Excellent Signal Retest OK. Press the Selector Button and will flash. Rotate the Selector Button until ON is seen.. Press the Selector Button to start the signal strength test. The test may last for up to 8 minutes. During this time, numbers ranging from 0 to are displayed. 0 indicates no signal available and shows excellent signal strength Fig. Baxi recommends locating the unit to give a signal strength of or. If the signal is low, move the unit to a more suitable location and retest.. Press the Selector Button at any time to interrupt the test or press to escape once the test has finished. Fig. Signal Strength Test. If the Manual Sync. process needs to be carried out see Section.0. c Baxi Heating UK Ltd 0

8 .0 Manual Sync. Function 8 L L. Synchronizing 080 day Wireless & 00 h Wireless The Programmer & Room Sensor and the Receiver can be synchronized using the method shown in Fig. 8 as follows: Fig.. Programmer & Room Sensor Selector Button Fig.. Receiver LED Display & Button. Start by setting up the Programmer & Room Sensor. Press and hold the Selector Button (Fig. ) for approx. seconds. HC will be seen on the display.. Rotate the Selector Button until SnC is seen in the display. HC SnC. Press the Selector Button and will flash. This display will only remain on the screen for approximately 0 seconds.. Now set up the Receiver. LED L will be flashing. Fig. 8. One of the following conditions will be seen. Hold for seconds SnC Go to Receiver Unit L Rapid Flash One flash every secs Boiler and Controller Synchronized. Two flashes every secs Communication error Three flashes every secs No communication yet Flash for sec NA for Sync sec flash every sec Synchronization initialisation See Fig. for detailed description L L Press & hold until slow flash L Slow Flash Return to Controller. If one flash is seen every seconds, the boiler and Programmer & Room Sensor are already synchronized. Return to the Programmer & Room Sensor and press Menu twice to exit the Synchronization menu.. If L shows flashes every seconds the units are not synchronized. Press and hold the Receiver Button until the rapid flash at L changes to a slow flash. SnC SnC ON...,,,. Return to the Programmer & Room Sensor where SnC will be flashing. Rotate the Selector Button until SnC ON is seen. Press the Selector Button and the display shows,,, counting down. When this process is complete, the unit will display End if synchronization has been successful. Press the Selector Button to return to the SnC screen then press to escape. 8. If Error 8 is still displayed, the unit hasn t synchronized correctly. Return to the beginning and repeat the process. Err Reposition & Retry End SnC Fig. 8. Manual Sync Process Diagram c 8 Baxi Heating UK Ltd 0

9 .0 Standby & Operating Mode. Standby and Operating modes. The controller can be set to either Standby Mode or Operating Mode. In Standby, both the Central Heating and Domestic Hot Water functions are switched. Fig. Unit in Standby Mode. Fig 0. Standby turned off.. In Standby the Boiler Frost Protection function is still activated and will fire the boiler if the temperature in the boiler drops below.. In Operating Mode, the boiler will respond to any preset Central Heating or Domestic Hot Water demand.. The screen display shows the current settings. Fig shows the unit in Standby Mode. Fig 0 shows Operating Mode.. Changing Standby and Operating Mode settings. To change the unit s settings, follow the flow diagram shown in Fig.. Press the Mode button and the Standby symbol will flash and is shown in the main display. The Central Heating and Domestic Hot Water symbols can also be seen.. Press the Selector Button once and will flash. The Central Heating and Domestic Hot Water symbols disappear.. Rotate the Selector Button clockwise until On is seen in the display.. Press the Selector Button once to confirm the selection and then Menu to return to the main screen. If Menu isn t pressed the display will return to the Main screen after approximately seconds. The unit is now in Operating Mode. In, the boiler will heat the property to the temperature set on the i-think Controller during the programmed timed Heating periods In REDUCED mode, the boiler will maintain a minimum temperature in the property. If at any time, day or night, the temperature falls below this value the boiler will fire until the temperature is achieved. In COMFORT, the boiler will constantly heat the property to the temperature set on the i-think Controller. NOTE: This will continue until the boiler is taken out of COMFORT mode. Heating or Hot Water set to To Escape (or wait secs) Fig. Standby & Operating Mode Diagram Time Band Time Band COMFORT room temperature REDUCED room temperature Domestic Hot Water setting Hourly Central Heating programme Hourly Domestic Hot Water programme c Baxi Heating UK Ltd 0 Table. Display Icons

10 8.0 Central Heating & Domestic Hot Water ON 8. Setting Central Heating to ON. Press the button and rotate the Selector Button until the flashing Central Heating symbol is seen in the display. Fig... Press the Selector Button once to confirm the setting and the will flash.. Rotate the Selector Button to scroll through the options available. In Central Heating, these are, REDUCED, COMFORT and. Press the Selector Button to confirm the setting.. Press to escape, or wait seconds and the unit will return automatically to the main display screen. NOTE: A delay during this process will cause the unit to revert back to the main screen. If this happens the process must be restarted. REDUCED COMFORT To Escape (or wait s) ON ECO To Escape (or wait s) 8. Manual Override of Room Temperature. The Room Temperature can be increased or decreased during a heating period by rotating the Selector Button to give the required temperature. Press the Selector Button to confirm the new setting.. The set temperature will return to the Comfort mode value at the next heating demand period. 8. Setting Domestic Hot Water to ON. For Combi boilers it is recommended that the Domestic Hot Water setting is left in the ON position. If it is necessary to alter the setting follow the process shown in Fig. 8. Service Warning. If the symbol Sd appears in the display please contact heateam as your boiler may require servicing. The contact telephone number is shown on the back page. Fig. Central Heating & Domestic Hot Water activation day Wireless day Wired h Wireless Fig. Typical Operating Modes. 0 c Baxi Heating UK Ltd 0

11 .0 Temperature Settings. Setting the Room Temperature (Comfort). To set the Room Temperature, press the button and SC ON will appear in the display with the current Room Comfort Set Point shown. SC ON Sr Ed Sd HU. Press the Selector Button and the Comfort Set Point will flash. This set point can be adjusted up or down by rotating the Selector Button.. Press the Selector Button again to confirm the set point and then press to return to the main display screen. The Comfort Set Point is now confirmed.. Manual Override of COMFORT setting SC ON Sr Ed Sd HU The Comfort Set Point can be increased or decreased during a heating period by rotating the Selector Button to give the required temperature. Press the Selector Button to confirm the new setting. The set temperature will return to the previous COMFORT mode value at the next heating demand period Setting the REDUCED Temperature. To adjust the REDUCED set point, press the button and rotate the Selector Button until Sr Ed appears in the display.. Press the Selector Button to access the menu. The current set point will be seen flashing. The set point can be adjusted up or down by rotating the Selector Button.. Press the Selector Button again to confirm the set point and then press to return to the main display screen. The REDUCED temperature is now confirmed. Boiler Flow Temperature Fig. Temperature adjustment diagram Fig. Outdoor Sensor Curve Graph c Baxi Heating UK Ltd 0 otc Menu Values Outdoor Temperature Example: For a minimum outdoor temperature of -0 and a required flow temperature of 80, the otc value should be set to.0. For further details please see Outdoor Sensor Kit - Part No Default Value Setting the Domestic Hot Water. To set the Domestic Hot Water temperature, press the button and rotate the Selector Button until Sd HU appears in the display.. Press the Selector Button and the current temperature set point will flash. The temperature can be adjusted up or down by rotating the Selector Button.. Press the Selector Button again to confirm the temperature and then press to return to the main display screen. The Domestic Hot Water temperature is now confirmed.. Setting the Outdoor Sensor Curve. To adjust the Outdoor Sensor value press and hold the Selector Button for approximately seconds to access the parameter menu. Rotate the Selector Button until otc is seen in the display and press the Selector Button to access.. Set the required temperature compensation value from the graph (Fig. ) by rotating the Selector Button and pressing to confirm. Press until the main screen is displayed. NOTE: This function can not be set or displayed from the boiler front panel when the Programmer and Room Sensor Controller is fitted.

12 0.0 Setting the Time & Day 0. To Set the Time.. From the main display screen press and rotate the Selector Button until the clock is displayed. Fig... Press the Selector Button once and the hour will flash. Rotate the Selector Button to increase or decrease the time. Press the Selector Button once to confirm the hour setting. The minutes display will now flash. day version only. Rotate the Selector Button to set the minutes and press the Selector Button once to confirm. The time is now set. Press until the main screen is displayed. NOTE: The clock will not update automatically so will require manual adjustment. 0. To Set the Day (00 day Wired & 080 day Wireless only). day version only. Set the Time as described above. Once the Time is confirmed by pressing the Selector Button, the day symbols on the right hand side of the screen will flash.. Rotate the Selector Button set the day. Monday =, Tuesday = etc. The current day is shown in a small circle. Press the Selector Button to confirm.. The correct time and day should now be shown in the display. Press once to return to the main display screen. - hrs + hrs - min + min Day Version Only - day + day = Monday = Tuesday = Wednesday = Thursday = Friday = Saturday = Sunday Fig.. Setting the Time & Day c Baxi Heating UK Ltd 0

13 PCH PdHU.0 Setting Heating & Domestic Hot Water. Setting the Central Heating. Press the button and rotate the Selector Button until PCH is seen in the screen. Fig.. Press the Selector Button once. h day -day version only: Press the Selector Button once and Day (Monday) will be seen flashing. The display can be set to either individual days, weekdays and weekend, or days identical. The h version does not have Day function displayed.. To set the day sequence, rotate the Selector Button until the required day is displayed. Press the Selector Button to confirm.. The screen displays the time and the letters Pr flashing. Press the Selector Button again and On flashes. (Pr = current setting, Pr, Pr & Pr are presets). 00:00 Pr Preset Programmes Pr Pr Pr. Press the Selector Button again and the time flashes. The first Timed On period can now be set. Rotate the Selector Button to set the desired Central Heating start time.. Press the Selector Button to confirm and the first timed Off period flashes. Use the Selector Button to set the required off period. Press the Selector Button once to confirm.. Repeat the above process for On, Off, On and Off time periods. If only Heating periods are required set On and Off to the same time (e.g. :00). 00:00 On. After Off has been set the screen will show the On time flashing again. If Programming is complete, press repeatedly to return to the main display screen.. Setting the Domestic Hot Water. Press and rotate Selector Button until PdHU is displayed. Fig.. Press the Selector Button to confirm and repeat the sequence as described above. On On 00:00 On 00:00 00:00 On 00:00 00:00 On Fig.. Setting Central Heating & Domestic Hot Water 00:00 c Baxi Heating UK Ltd 0

14 .0 Parameter Codes. Programmer & Room Sensor Functions. To access the Menu, press and hold the Selector Button for approximately seconds. The parameters can be accessed by rotating the Selector Button. Display Description Default HC.Ao rte dh Assigns the Programmer & Room Sensor to heating circuit. Sets the Programmer & Room Sensor as Master (CEn). Enables the USER to adjust the reduced room temperature setting Enables the USER to adjust the DHW temperature and hourly programming CEn Enabled Enabled rel Sets the DHW mode: h: DHW always active CHP: DHW is enabled according to the CH hourly programme DhP: DHW is enabled according to the DHW hourly programme Combi h ofs Un SoFt ost osp tlr ICE Sets the offset of the room sensor. Used to correct the temperature value read by the sensor if this differs from the actual temperature. Selects the temperature unit of measurement ( or F) Displays the software version Not used Not used Not used Enables / Disables room anti-freeze function (from + C to reduced room temperature) = disabled = settable 0 Read only N/A N/A N/A otc Sets the kt curve for external weather sensor 0000 (0..0). (See Section.). rts Mod. ULt TSP Snc TSt End Enables (ON) / Disables () the room sensor. Enables (ON) / Disables () room temperature modulation. Sets the maximum CH flow temperature (Max CH) Accesses the Pxx board parameters menu Synchronization of Programmer & Room Sensor (080 & 00) with the boiler. Refer to Sections and of this manual Radio transmission test (WIRELESS only). The function lasts 8 minutes or when the Selector Button is pressed. The display shows the numbers to (=% - =00%) To return to the main screen. ON ON 8 * * Adjustment is required for Low Temperature or Underfloor heating systems. Table. Parameter codes c Baxi Heating UK Ltd 0

15 .0 Error Codes Receiver L L. Error Codes. Some error codes can be reset. If an error code is seen in the display use the reset procedure to try and remove the fault. Fig.. Normal Operation L Flash L Flash L Flash. Press the Selector Button once and rotate immediately until rst is shown in the display.. Press the Selector Button again and the error should reset. If the error doesn t reset, consult the boiler manual for further information. s s. Resetting the sd - Service Due Code Wired - No Communication between Boiler & Transmitter Wireless - No Communication between Room Unit & Transmitter Parameter Change Initialization Phase between Transmitter & Boiler L Flash x L Flash x L Flash x s L Flash x L Flash x L Flash x s s Fig 8. Receiver status indicator LEDs Fig. Resetting Error Codes L Flash L Flash s s s L Flash s s s s rst Fig 0. Resetting the Service Due Code.. Press the Selector Button once and 000 will be displayed.. Rotate the Selector Button until 0 is seen is the display.. Press the Selector Button once and Service Due will clear. Fig 0. NOTE: Resetting this function without completing the required service will invalidate your warranty.. Boiler Control. If necessary, control can be transferred back to the boiler. Either remove the unit from its cradle, or remove the plug from the Receiver, then turn the power to the boiler off and back on Gas Valve Connection Cable Gas Valve Fault Central Heating NTC Fault Flue NTC Fault Central Heating Return NTC Fault Calibration Required Pre-circulation Fault Safety Thermostat Operated Primary System Water Pressure Too High Primary System Water Pressure Too Low Circulation Fault (Primary) Flame Failure Flue NTC Operated Interruption Of Gas Supply or Flame Failure Elapsed Time - Gas Valve Open Without Gas Interruption Of Gas Supply (Internal Error) Flow/Return Sensor Temperature Test Fan or Fan Wiring Fault Circulation Fault (Dry Fire) Hot Water NTC Fault False Flame Programmer & Room Sensor Error Codes (See Sec..) 8 Error between Boiler & Receiver 8 Error between Programmer & Room Sensor & Receiver Table. Error Codes c Baxi Heating UK Ltd 0

16 .0 X X X X X X X X X X X All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. BAXI A Trading Division of Baxi Heating UK Ltd (8) Brooks House, Coventry Road, Warwick. CV LL After Sales Service 08 8 Technical Enquiries 08 8 Website e&oe c Baxi Heating UK Ltd 0 Comp No (/)

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS A it KIT UNITÀ AMBIENTE E INTERFACCIA A LED PER IL CONTROLLO DELLA TEMPERATURA AMBIENTE DEL LOCALE en KIT ROOM UNIT AND LED INTERFACE ROOM TEMPERATURE CONTROL ACCESSORY de RAUMGERÄT UND LED-SCHNITTSTELLE

More information

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY RC 06 0712_1403 it - Istruzioni TELECONTROLLO en - Remote controller instruction hu - Utasítás TÁVVEZÉRLÉS ru - Руководство по эксплуатации pl - Instrukcja obsługi { 1. Commissioning of the boiler 26 2.

More information

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat FOR GREENSTAR 25 HE and GREENSTAR 30 HE MODELS Hol Man Auto Day SIGNAL HEATING ON OVERRIDE

More information

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No. United Kingdom en Fitting & Commissioning Instructions Outdoor Sensor Kit EcoBlue Combi and System Range Kit Part No. 7214286 (System) Kit Part No. 7213356 (Combi) These instructions should be read in

More information

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat. ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat. LARGE RECEIVER: 24CDi, 26CDi Xtra, 28CDi, 35CDi Mk I and 35CDi Mk II SMALL RECEIVER: 24i Junior, 28i Junior and Si Mk II

More information

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Easy-Stat. Wireless Programmable Room Thermostat Pt No Easy-Stat Wireless Programmable Room Thermostat Pt No 7.2000050 1 Installing the receiver The receiver must be installed into the boiler control panel, refer to the boiler installation manual for guidance.

More information

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler User s Operating Instructions & Important Warranty Information Baxi Megaflo System HE IE Range Gas Fired Wall Mounted Condensing Boiler Please keep these instructions in a safe place. If you move house,

More information

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5 4 ±0.5 12.0 Servicing 12.2 Annual Servicing Inspection (Cont) Flame Sensing 5 ±1 10 ±1 Position Fig. 45 Spark Ignition 5. Remove the clip securing the gas feed pipe to the air/gas venturi. Disconnect the

More information

Combi Eco Elite Range. User s Guide and Important Warranty Information

Combi Eco Elite Range. User s Guide and Important Warranty Information User s Guide and Important Warranty Information Combi Eco Elite Range Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd

More information

Multifit. Installation & Commissioning Instructions

Multifit. Installation & Commissioning Instructions United Kingdom en Multifit Part No. 7683084 Installation & Commissioning Instructions IFOS - In Flue Outdoor Sensor Kit Temperature Compensation Device Suitable for Combination boilers fitted in conjunction

More information

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL ENGLISH REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL DANGER! Serious danger to safety and health ATTENTION! Possible dangerous situation for the product and the environment

More information

Drayton Digistat +3RF

Drayton Digistat +3RF Drayton Digistat +3RF Programmable Room Thermostat Wireless 5-2 Day / 7 Day Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845

More information

User Guide Y9420H Sundial RF 2 Pack 2

User Guide Y9420H Sundial RF 2 Pack 2 PLEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this product and any packaging or literature in an appropriate way WHAT IS A PROGRAMMER?...an Explanation for Householders (as recommended by the

More information

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT92 WIRELESS DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT92 family of wireless digital room thermostats is a range of market leading products designed to provide comfort with economy

More information

Modulating clock thermostat

Modulating clock thermostat EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5

More information

BeSMART Thermostat. EN Thermostat Manual

BeSMART Thermostat. EN Thermostat Manual BeSMART Thermostat EN Thermostat Manual 1 Basic information Desired room temperature (up to 3 set) Room temperature Heating request (if ON/OFF connected Flame presence (if OT-Bus connected) Cooling mode

More information

Model: Slimline-RF. 1 Slimline Series

Model: Slimline-RF. 1 Slimline Series Model: Slimline-RF Model: Slimline-RF 1 Slimline Series Table of Contents Product Image 1 Holiday Programming 22 Table of Contents What is a Programmable Room Thermostat? 2 3-4 Setting the Hot Water Switching

More information

danfoss Heating Solutions 5

danfoss Heating Solutions 5 4. Technical settings...22 4.1 Deactivating automatic daylight saving time...22 4.2 Adjusting to radiator/room...23 4.3 Deactivating intelligent control...23 4.4 Technical specifications...24 5. Safety

More information

Vokèra OpenTherm 711 without external sensor connected

Vokèra OpenTherm 711 without external sensor connected Vokèra OpenTherm 711 without external sensor connected Setup guide to using the OpenTherm Control without an external weather compensation sensor fitted. If you are unsure if there is an external sensor

More information

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver TFC GROUP LLP Programmable RF Room Thermostat ET4 ET4 heat/cool 5+1+1 day RF programmable room thermostat 1 N 2 ET4 Receiver L L Supply Live N Supply Neutral 1 Live Return 2 Live Feed 20V AC 50Hz 24 240V

More information

Vokèra OpenTherm 711 with external sensor connected

Vokèra OpenTherm 711 with external sensor connected Vokèra OpenTherm 711 with external sensor connected Setup guide to using the OpenTherm Control with an external weather compensation sensor fitted. If you are unsure if an external sensor is fitted check

More information

Honeywell Homes T3, T3M & T3R

Honeywell Homes T3, T3M & T3R Honeywell Homes T3, T3M & T3R PRODUCT SPECIFICATION SHEET Honeywell T3 & T3M Programmable Thermostat Honeywell T3R Programmable Thermostat The T3, T3M & T3R thermostats are designed to provide automatic

More information

User s Operation Instructions & Important Warranty Information

User s Operation Instructions & Important Warranty Information United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Plus 18s - 24s - 30s 24c - 28c - 35c - 39c Please keep these instructions

More information

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat? Table of Contents Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat? 3-4 Power ON/OFF 26 Holiday Programming 27 Installation

More information

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h Please keep these instructions in a safe place.

More information

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler You can rely on User Guide and Important Warranty Information Promax System HE Plus A Range Condensing System Boiler Please keep these instructions in a safe place. If you move house, please hand them

More information

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler User s Operating Instructions Baxi Combi 05 HE Gas Fired Wall Mounted Condensing Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

Operating your heating system with the Prefect PRE5701 Programable Thermostat

Operating your heating system with the Prefect PRE5701 Programable Thermostat Operating your heating system with the Prefect PRE5701 Programable Thermostat 1 Your central heating system has been designed to provide a comfortable and flexible living environment, enabling you to have

More information

Model: Touch-RF. 1 Wireless Series

Model: Touch-RF. 1 Wireless Series Model: Touch-RF Model: Touch-RF 1 Wireless Series Table Of Contents Product Image 1 Locking the Keypad 18 Table of Contents 2 Temperature Control 19 What is a Programmable Room Thermostat? 3-4 Hot Water

More information

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH) USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Contents Introduction...

More information

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT90 DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT90 family of digital room thermostats is a range of market leading products designed to provide comfort with economy in modern heating

More information

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock RGR150 manual-final-091908:layout 1 9/19/08 8:59 AM Page 1 RGR150 USER S MANUAL Wireless Rain Gauge with Thermometer and Clock INTRODUCTION Thank you for selecting this Wireless Rain Gauge. This device

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

A homeowner s guide to the Baxi Neta-tec Combi

A homeowner s guide to the Baxi Neta-tec Combi A homeowner s guide to the Baxi Neta-tec Combi For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk A history of quality and innovation 1866

More information

User Guide for EHE & EHE Programmable Room Thermostat

User Guide for EHE & EHE Programmable Room Thermostat User Guide for EHE0200153 & EHE0200154 Programmable Room Thermostat Description The EHE0200153 & EHE0200154 are programmable room thermostats designed to control your heating system efficiently, providing

More information

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax: MC200 Users Instructions BSI Registered Firm HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: 01460 53535 Fax: 01460 52341 FM 414 Ind. & Comm. Air Heaters; Air Moving Equipment; Flues & Chimneys;

More information

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET Honeywell T4 & T4M Programmable Thermostat Honeywell T4R Programmable Thermostat The T4, T4M and T4R thermostats are designed to provide automatic time and

More information

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler 0 4 You can rely on User Guide and Important Warranty Information Performa 4 Eco HE Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

ECL Comfort 210 / 296 / 310

ECL Comfort 210 / 296 / 310 User Guide ECL Comfort 210 / 296 / 310 English version www.danfoss.com Safety Note Necessary assembly, start-up, and maintenance work must be performed by qualified and authorized personnel only. 2 Danfoss

More information

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents. 1 Model: Available in : Sapphire Black and Glacier White Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation Procedure

More information

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Wall Hung Boiler Room Thermostat OR30 OT Thermostat 8 733 201 137-00.1O Wall Hung Boiler Room Thermostat OR30 OT Thermostat Operating Instruction 6 720 812 418 (2014/07) en 2 Contents Contents 1 Symbols and safety precautions..................................

More information

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Linea HE High efficiency combi boiler Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation

More information

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi Contents Introduction... Ideal Touch kit contents...

More information

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION FORMAT DGT HE 199838 User instructions Please read the Important Notice within this guide regarding your

More information

SAT-3 Room Temperature Controller

SAT-3 Room Temperature Controller SAT-3 Room Temperature Controller USER S OPERATING INSTRUCTIONS Contents Introduction 5 Features Summary 5 Operation 7 On/Off 7 Room Temperature Adjustment 7 Operating Mode Selection 8 Fan Speed Selection

More information

Programmable Thermostat

Programmable Thermostat Set & $ave Programmable Thermostat Installation and Operation Manual English Model 44360 Form# 42710-01 20091204 2009 Hunter Fan Co. 2 Table of Contents Important Information... 5 Tools... 6 Uninstalling

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

Condensing Boiler RS100 Controller Training Program

Condensing Boiler RS100 Controller Training Program Condensing Boiler RS100 Controller Training Program Training Program #501102A 062311 www.rinnai.us 2009 Rinnai America Corporation Features and Benefits The RS100 connects directly to the boiler and acts

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature PLEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this product and any packaging or literature in an appropriate way WHAT IS A PROGRAMMER?...an Explanation for Householders (as recommended by the

More information

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY USER GUIDE RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Installation, Start-Up, and Operating Instructions

Installation, Start-Up, and Operating Instructions Installation, Start-Up, and Operating Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 GENERAL...1 INSTALLATION...1-5 Install Batteries...1 Select Transmitter Location (Optional)...1 Mount Transmitter

More information

CS027 User Instructions

CS027 User Instructions CS027 User Instructions Battery Powered 7 Day Programmable Room Thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. The CS027 programmable

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

CentaurPlus ZW and HRT4-ZW

CentaurPlus ZW and HRT4-ZW CentaurPlus ZW and HRT4-ZW Installation Instructions The Horstmann CentaurPlus ZW combined wireless room stat and timeswitch allows a combi boiler system to have a room thermostat added without the need

More information

irad Wireless Controller

irad Wireless Controller irad Wireless Controller The irad Wireless Controller is a wireless (433MHz) programmable thermostat giving high precision room temperature control. It also had a seven day programmer with up to six temperature

More information

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions - Brochure tekmarnet 4 Thermostat 542 D 542 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring

More information

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY THERMOSTAT PROGRAMMABLE 7-DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Riello s weekly programmer.. This central heating control device is

More information

User Manual THR870CUK Programmable Thermostat

User Manual THR870CUK Programmable Thermostat User Manual UK Programmable Thermostat 50051984-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 20-31). If you are not experienced in wiring electrical

More information

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH) Installation guide Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Ideal Touch

More information

ES-LCD User Control SD Card Location

ES-LCD User Control SD Card Location SD Card Location Addendum to Leaflet Number 671415 The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU Checking SD Card for secure location Due to the possibility of movement during transit,

More information

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure 1 Model: 1 Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure 1 2 3-4 5-6 Mode Select Pairing the ProTouch iq Hub Pairing the ProTouch iq What

More information

Model: Touch-RS. 1 Touch-RS

Model: Touch-RS. 1 Touch-RS Model: Touch-RS Model: Touch-RS 1 Touch-RS Table of Contents Product Image 1 Temperature Hold 15 Table of Contents 2 Holiday Programming 16 What is a Programmable Room Thermostat? Installation Procedure

More information

- Data Brochure tekmarnet 4 Thermostat 542e

- Data Brochure tekmarnet 4 Thermostat 542e - Data Brochure tekmarnet 4 Thermostat 542e D 542e 03/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

USER'S OPERATING INSTRUCTIONS

USER'S OPERATING INSTRUCTIONS SAT-2 Thermostat COOL FAN DRY HEAT AUTO SLEEP SWING AUTO ZONE SUN MON TUE WED THU FRI SAT HEATER ON OFF ERR UNIT USER'S OPERATING INSTRUCTIONS CONTENTS Page Introduction 3 Features Summary 3 Display 4

More information

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS Square button version see Page 11 7716 192 008 Mk1 Round Buttons SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS General information about the boiler is given in the Users Instruction Leaflet

More information

Model: Slimline-B. Battery Series

Model: Slimline-B. Battery Series Model: Slimline-B Model: Slimline-B 2 Battery Series Table of Contents Product Image 1 Holiday Programming 20 Table of Contents 2 Frost Protection 21 What is a Programmable Room Thermostat? Installation

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists Heat Boxes with Wireless Data Transmission Working towards a cleaner future heating specialists Intelligent Comfort Potterton Commercial, the UK s leading supplier of commercial boilers introduces an intergrated

More information

On initial power up the thermostat will guide you through set up procedure for the following:

On initial power up the thermostat will guide you through set up procedure for the following: Operating Guide: for the Warmup 3iE Programmable Thermostat INTRODUCTION Your thermostat s default screen is the Home Screen. This screen displays important information such as the time, current floor

More information

C-Stat 17-ZW User Instructions

C-Stat 17-ZW User Instructions C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.

More information

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on You can rely on User Guide and Important Warranty Information Suprima HE Range Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

Owner s Manual. Part Number 33CS250-RC

Owner s Manual. Part Number 33CS250-RC CONTENTS Page GENERAL... 1 CONFIGURATION... 1-4 Transmitter Display... 1 Transmitter Indicator... 1 Transmitter Front Panel Buttons... 1 Set Clock... 2 Programming Thermostat Schedules... 3 OPERATION...5

More information

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo neo Model: Available in : Sapphire Black and Glacier White 1 Wavin neo Table of Contents Product Image 1 Optional Features 19-22 Table of Contents 2 Re-calibrating the Thermostat 23 What is a Programmable

More information

REA22 Room Temperature Controller

REA22 Room Temperature Controller REA22 Room Temperature Controller Basic Documentation Issue: 2.0 Controller series: A CE1P2276E 31.03.1999 Siemens Building Technologies Landis & Staefa Division Siemens Building Technologies Ltd. Landis

More information

User Manual THR842DUK Wireless Digital Thermostat

User Manual THR842DUK Wireless Digital Thermostat User Manual THR842DUK Wireless Digital Thermostat 50051983-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-23). If you are not experienced in

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WH THE USER ECOMFORT PLUS 25 HE User instructions All descriptions and illustrations provided in this manual have been carefully prepared but we reserve the right to make

More information

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX 1 EUROSTER 2510TX Introduction Congratulations on the purchase of your new Digital Thermostat. Thanks to the latest microprocessor technology, the thermostat offers many convenient and energy-saving features.

More information

DOMESTIC HOT WATER Follow operational sequence

DOMESTIC HOT WATER Follow operational sequence DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset

More information

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s Great Britain EN High-efficiency wall-hung boilers Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s User s Operation Instructions & Important Warranty Information Please keep these instructions in a safe place.

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat Description Features: Scandinavian design with white backlight; User-friendly interactive interface; Room temperature display and settings; 12 or 24 hour clock display and settings; Three-speed manual/automatic

More information

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler United Kingdom en User Guide Condensing Central Heating Boiler Main Eco Elite Combi 5-0 Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Mynute Standard efficiency system boiler 12e - 16e - 20e Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards

More information

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model: Available in : Sapphire Black and Glacier White. 1 Series Model: Available in : Sapphire Black and Glacier White 1 Series Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation

More information

prestige Control Application Supplement WARNING

prestige Control Application Supplement WARNING prestige Control Application Supplement WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions within this

More information

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi Quick start guide Connected wireless room thermostat Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi Introduction Welcome to the Ideal Touch quick start guide. This guide is designed

More information

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS Heating Controller SDC District Heating Controller DHC 43 OPERATING INSTRUCTIONS Copyright 2002 Honeywell Inc. EN2H-0220 GE51 R0802 SDC / DHC 43 Operating Instructions EN2H-0220 GE51 R0802 Contents SDC

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTALLING BATTERIES INSTALLATION INSTRUTIONS RT7 WIRED 7 DAY PROGRAMMABLE ROOM THERMOSTAT 1- Remove the batteries cover which is placed on the front of thermostat. 2- Insert the 2 batteries

More information

Please read this manual carefully before installation and use.

Please read this manual carefully before installation and use. Doylestown, PA 18902 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: support@scillc.com - www.scillc.com FMT-24-SUPER-PROG With freeze protection Owner s Manual Installation and Operating Instructions

More information

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating MAKING MODERN LIVING POSSIBLE TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating User Guide TP7001 Electronic 7 Day Programmable Room Thermostat For a large print version of these

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Rotex Underfloor Heating User Guide

Rotex Underfloor Heating User Guide Rotex Underfloor Heating User Guide Your new Rotex underfloor heating In this guide you will find information and guidelines that will allow you to run your underfloor heating system in the most energy

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Set & $ave. Model Programmable Thermostat. installation and operation manual

Set & $ave. Model Programmable Thermostat. installation and operation manual Set & $ave Programmable Thermostat installation and operation manual Model 44110 42707-01 8-21-06 2 Table of Contents Important Information... 5 Tools... 6 Uninstalling the Existing Unit... 7 Installing

More information

User Manual THR872CUK Wireless Programmable Thermostat

User Manual THR872CUK Wireless Programmable Thermostat User Manual THR872CUK Wireless Programmable Thermostat 50051985-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 20-31). If you are not experienced

More information

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL M/A MANUAL ESRTPRF Wireless Programmable Room Thermostat, with Delayed & Optimum Start User and Installation Instructions INDEX User Instructions What is a Programmable Room Thermostat? 1 Introduction