The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors.

Size: px
Start display at page:

Download "The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors."

Transcription

1 4. LIST OF EQUIPMENT SUPPLIED The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors. The item numbers sown correspond to the operating diagram enclosed with this tender SLUDGE RECEIVING UNIT (OPTION - SECTION 1000) Client s responsibility DRYING UNIT (SECTION 2000) Supply of dehydrated sludge The equipment supplied comprises Two twin type feed pumps Item... PO Type... eccentric rotor Supplier... WANGEN Body material... Perbunan Rotor material... V2A (stainless steel) Flow... 0,8 4,3 m 3 /h Motor output kw Maximum pressure bars Equipped with a feed hopper each with a capacity of 4,5 m 3 (item RF 2002, 2003) and a safety system to prevent running empty and excess pressure. With piping and control to permit filling of client^s cludge silos (see process flow diagram) The pipework connecting to the thin layer dryer and the sludge silos. The requisite instrumentation (see. PFD) First treatment stage A thin layer dryer Item... EF 2006 Type... horizontal, G 3 Length m Sealed... by stuffing box Transmission... belt Motor output kw Material:. Fins... Stainless steel. Stator , Dillimax 690T or similar. Rotor... Stainless steel Weight empty... Weight when operating kg kg The equipment will be constructed in accordance with the German TüV and AD- Merkblatt norms. Adaptation to any other norm will incur additional costs

2 A chopper Item... CH 2007 Type... CHP 15A Changing... Automatic Rotation speed rpm Material in contact with the sludge... Stainless steel Transmission... Belt Motor output kw Including automatic cleaning of the cutters. Compressed air (6 bars) is required for the automatic cleaning system. The Client is responsible for supplying the air compressor and the supply circuit. For ease of rinsing the sieves with water a single rail lifting device is provided by Innoplana. The area between chooper, belt dryer and rinsing station (to be supplied by the client) is being closed off the rest of the building so that the polluted air can be separately removed to the vent air. Thus another c m3/h of vent air are to be removed A steel construction to support the thin film dryer which has to be superimposed to the belt dryer (as well as the heat recovery system) with stairs and safety rails. Clearance between bottom an lower limit of steel construction c. 4.8 m. Clearance for hook of travelling crane from bottom : c 8,5m A distribution belt to the belt conveyor Item... TD 2008 Type... CHP Changing... Automatic Conveyor belt material... PVC External material... painted carbon steel (RAL 5005) and stainless steel 304 Transmission... Belt A rinsing water tank Item... RF 2030 Material:... stainless steel External material... painted carbon steel (RAL 5005) and stainless steel 304 Including the pipework between the tank and the connection to the drying unit. The Client is responsible for the rinsing water (treated effluent) supply pipe and the other systems (valves, pumps, etc.). The requisite instrumentation (see PFD)

3 Second treatment stage A belt conveyor Item... EF 2009 Number of belts... 5 Motor output (1 per belt)... 5 x 0,5 kw a crusher Item... QC 2010 Motor output... 3 kw Temperature regulation Belt dryer thermal loop A bracket-mounted recirculating fan Item... CV 2011 Material... Carbon steel Motor output kw Maximum air temperature C An exchanger for partially condensing the steam from the second stage, situated on the outlet from the belt dryer Item... EW 2021 Type... steel pipes Hot fluid... Second stage steam Material... Stainless steel An exchanger for condensing the steam from the first stage and reheating the steam from the second stage, situated on the outlet from the belt dryer Item... EW 2022 Cold fluid... Second stage steam Hot fluid... First stage steam Body material... Stainless steel Tube material... Glass An additional exchanger for reheating the second stage steam, situated on the outlet from the belt dryer Item... EW 2023 Cold fluid... Second stage steam Hot fluid... Coolant Body material... Painted carbon steel (aluminiumbronze) Tube material... Galvanised steel

4 A vent to be connected to the air treatment system; system and connection to be the Client s responsibility Cooling loop for the last dryer belt A bracket-mounted cooling air fan Item... CV 2013 Material... Carbone steel Motor output... 3kW Maximum air temperature C An exchanger for cooling the dryer s air on the last belt Item... EW 2026 Type... fine tube Hot fluid... Last dryer belt air Body material... Carbon steel Tube material... Copper / Aluminium The Client is responsible for the pipework supplying the treated effluent as far as the connection flanges on the exchanger Condensate cooling loop A recirculation pump Item... PO 2014 Motor output kw Operating temperature to 60 C An exchanger for condensing the steam and cooling the condensate Item... EW 2024 Cold fluid... Industrial water Hot fluid... First stage condensate Body material... Stainless steel 304 Tube material... Galvanised steel An exchanger for maintaining the coolant temperature Item... EW 2025 Hot fluid... Industrial water Body material... Stainless steel 304 With a bypass exchanger..ew2028 permitting to clean the main exchanger without stopping the dryer by closing/opening manual valves

5 An expansion vessel Item... RF 2020 Volume litres Material... Plastic-coated carbon steel The Client is responsible for the pipework supplying the treated effluent as far as the connection flanges on the exchanger. Heat Recovery The energy will be recovered from the cooling loop instead of temperature maintenance via exchanger EW An exchanger EW 2027 will be supplied addtionally to EW An exchanger for maintaining the coolant temperature Item... EW 2027 Cold fluid... fluid for reheating Hot fluid... Industrial water Condensate recovery Handling A condensate recovery tank Item... RF 2016 Volume... 0,7 m 3 Material... Stainless steel A bracket-mounted air extraction fan on the condensate tank for recirculating this air to the belt dryer Item... CV 2017 Material... Epoxy painted aluminium Motor output... 1,5 kw A condensate pump to enable the tank to be drained Item... PO 2018 Motor output... 0,4 kw Operating temperature C The pipework supplying the condensate to the tank and then from the tank to the drain pump. The Client is responsible for the pipework for the condensate from the drain pump, from the pump s flange. The provision of a travelling crane by the client.

AIRWASH Abrasive Recycling System

AIRWASH Abrasive Recycling System AIRWASH Abrasive Recycling System Racohi AIRWASH Abrasive Recycling System is designed & manufactured with high quality materials to be the most robust and reliable in the industry. It is an innovative

More information

METAL CHIP AND COOLANT MANAGEMENT PLANTS

METAL CHIP AND COOLANT MANAGEMENT PLANTS indass METAL CHIP AND COOLANT MANAGEMENT PLANTS 1 Industrie Associate s history Industrie Associate s factory 2 Production department CONVEYORS Vertical Centrifuges Wet metal swarf can contain up to 25%

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

Halton Rex 600 Basic R6B - Active chilled beam

Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying

hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying A robust and proven design for high capacity sludge drying Sludge, the by-product of wastewater treatment, consists

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5 Refrigeration & Air Conditioning Experiment No. 5 1.0 Title of the experiment: - Experiment No. 5 Dismantling and assembly of hermetically sealed compressor. 2.0 Prior Concepts: - Compressor function in

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

SECOND HAND ASPHALT PALANT FOR SALE

SECOND HAND ASPHALT PALANT FOR SALE . BITUMEN STORAGE DREDGING EQUIPMENT QUARRY INSTALLATIONS. Unit 1, Burnhouse Industrial Estate, Burnhouse Industrial Estate, Whitburn, West Lothian, EH47 0LQ SECOND HAND ASPHALT PALANT FOR SALE Manufacturer:

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab Steam Generator (Boiler) ME 268 Model Lab Aashique Alam Rezwan Lecturer Department of Mechanical Engineering, BUET, Dhaka-1000 http://teacher.buet.ac.bd/aashiquear ME 268 Aashique Alam Rezwan 1 Modern

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

Granulators. Piovan Granulators. RSP 15 Series. PIOVAN SpA. Marketing Dept. Lucio Girardello. Mktg Dept (l&g) RSP 15-eng re.01 modification reserved

Granulators. Piovan Granulators. RSP 15 Series. PIOVAN SpA. Marketing Dept. Lucio Girardello. Mktg Dept (l&g) RSP 15-eng re.01 modification reserved Granulators Piovan Granulators RSP 15 Series PIOVAN SpA Marketing Dept. Lucio Girardello 1 Mktg Dept (l&g) RSP 15-eng re.01 modification reserved New RSP 15 Series The new low speed RSP 15 Series is the

More information

Boretech China Make, Pet Bottles Recycling Line Ref Id SM4325 (Details-Specification mentioned hereunder are for indicative purpose only) DESIGN DATA 1.1 Capacity - PET bottles input : 1,500 kg/h - Dry

More information

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R CNG PSB Industries NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R PSB Industries PSB Industries Inc., General Air Division, specializes in the Design and Fabrication of compressed

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

Quality & Service Since For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying

Quality & Service Since For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying Quality & Service Since 1908 For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying Features & Benefits Why it will pay you to have our Metal Turnings Crusher in

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

GRP Ducting and Glass Tube Heat Exchanger Installation

GRP Ducting and Glass Tube Heat Exchanger Installation 2 GRP Ducting and Glass Tube Heat Exchanger Installation Don Valley Maltings Division Don Valley Engineering is the leading UK provider of Process Plant and Support to the Malting Industry, and the only

More information

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING white paper HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING Better Thermal Processing Results Begin with Selecting the Right Technology Authored by Rob Grady Director of

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

PAPER MILL MANUFACTURER OF SEVERAL TYPES OF BOARDS AND PACKAGING GRADES

PAPER MILL MANUFACTURER OF SEVERAL TYPES OF BOARDS AND PACKAGING GRADES PAPER MILL MANUFACTURER OF SEVERAL TYPES OF BOARDS AND PACKAGING GRADES The paper mill produces papers and boards made with wood pulp and with recycled fibers. Production includes file folder grades and

More information

ZD Tunnel Inline Cleaning Systems suginocorp.com Zippel GmbH

ZD Tunnel Inline Cleaning Systems suginocorp.com Zippel GmbH The ZD Series is our innovative response to the increasing diversity of parts requiring conveyor, chain, or fixtured in-line washing systems. Zippel through-feed cleaning machines can be custom-fit to

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

Commercial Hot Water Solutions Ltd.

Commercial Hot Water Solutions Ltd. FOR THE SUPPLY OF: Hot Water Generators Single & Twin Coil Vessels Buffer Vessels Gas Fired Continuous Flow Water Heaters with Buffer Storage www.chwsltd.co.uk CHWS Ltd provides specialist services for

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly

More information

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW Rohde, Mathias Content 1. Types of radioactive residuals 2. Treatment and conditioning facilities 3. Storage of radioactive

More information

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame

More information

AIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING

AIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING AIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING CHEMICAL PLANTS CURING ROOMS DRYING KILNS FACTORIES GASIFICATION PLANTS GREENHOUSES PAPER MILLS

More information

ASPHALT PLANT. atlastechnologiesindia.com

ASPHALT PLANT. atlastechnologiesindia.com ASPHALT PLANT MOBILE PLANT VARIANT: MDM 25 (20-30 tph) atlastechnologiesindia.com AGGREGATE FEEDING CONVEYOR AGGREGATE FEEDER In our mobile asphalt drum mix plant all the four bins are fitted with individual

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products

More information

Introduction to AD-Engineering - Plant components I. R. Waltenberger, R. Kirchmayr

Introduction to AD-Engineering - Plant components I. R. Waltenberger, R. Kirchmayr Introduction to AD-Engineering - Plant components I R. Waltenberger, R. Kirchmayr Reactor mixing - Mixing of fresh substrate with digester sludge - Even distribution of heat in the fermenter - Distribution

More information

Air Handling Units. Real HVACR people who understand your needs.

Air Handling Units. Real HVACR people who understand your needs. Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering

More information

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

TopMaster Air Handling unit. Installation instructions

TopMaster Air Handling unit. Installation instructions Installation instructions Safety Instructions Operation of Air Handling units and accessories WARNING Installation may only be carried out by qualified personnel. Before taking the air handling unit into

More information

Information on Feeder Systems ProMinent Australia

Information on Feeder Systems ProMinent Australia Information on Feeder Systems ProMinent Australia Powders that ProMinent have provided packages for: Sodium fluoride Sodium silicofluoride PAC Soda ash Lime Alum Potassium permanganate Calcium Hypochlorite

More information

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Q: How is the WSAC a closed-loop cooling system? A: The WSAC is a closed-loop cooling system because the process loop being cooled is inside the tube bundles

More information

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business Coal Handling and Processing Advanced Solutions for Coal-Related Environmental Dust Control Better Air is Our Business Coal Handling and Processing Industry Leader Our Qualifications For more than 85 years,

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

Halton Rex for Vario R6O - Variable air volume chilled beam

Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

SR10. Rotative blowing for large mass productionof packagings from 0,1 L to 0,75 L

SR10. Rotative blowing for large mass productionof packagings from 0,1 L to 0,75 L SR10 Rotative blowing for large mass productionof packagings from 0,1 L to 0,75 L SR10 PRODUCTION : Maxi Dimensions : Closing force : 0,7 T Volume : 750 cm3 Height : 195 mm Diameter : 100 mm MAXIMUM USUAL

More information

PUMPKIN SEED HARVESTING TECHNOLOGY 2019

PUMPKIN SEED HARVESTING TECHNOLOGY 2019 PUMPKIN SEED HARVESTING TECHNOLOGY 2019 Moty GmbH Piesing 20, AT 4846 Redlham office@moty.at www.moty.at Engineering changes, literal mistakes and prices are subjects to change Your reliable partner for

More information

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available. PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING

More information

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger

More information

PELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian

PELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian PELLET MILL N-MIDI pellet mill machine is projected and manufactured in accordance with CE norm about construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw. Slim design and acoustic comfort Saves up to 40% floor space Capacity up to 50 kw Free cooling Water misting Use Drycoolers in this range are mainly designed for cooling water or glycol/water mix for:

More information

Technical Specification

Technical Specification Cochran Ltd Newbie Works, Annan, Dumfries & Galloway, Scotland, UK DG12 5QU Telephone: +44 (0)1461 202111 Fax: +44 (0)1461 205511 Email: info@cochran.co.uk www.cochran.co.uk COCHRAN HEAT RECOVERY Package

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

Liquid Ring Vacuum Pumps, Compressors and Systems

Liquid Ring Vacuum Pumps, Compressors and Systems Helmut Bannwarth Liquid Ring Vacuum Pumps, Compressors and Systems Conventional and Hermetic Design Translated by Christine Ahner WILEY- VCH WILEY-VCH Verlag GmbH & Co. KGaA XIII Foreword VII Preface IX

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors

More information

EKK Anlagentechnik. Plastics and Environmental Technology. Update 01/2018. certified acc. to ISO 9001 ISO 14001

EKK Anlagentechnik. Plastics and Environmental Technology. Update 01/2018. certified acc. to ISO 9001 ISO 14001 EKK Anlagentechnik Plastics and Environmental Technology Contents Company portrait company sites manufacturing Scope of services planning production installation service / maintenance quality management

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

Shyam Enterprises 9 PACKAGE UNIT

Shyam Enterprises 9 PACKAGE UNIT Shyam Enterprises 9 PACKAGE UNIT 59 Reaction Distillation Unit The Unit has been designed to suit the customers requirement of combination of versatile reaction/distillation or combination for pilot plant

More information

TECHNICAL INFORMATION L / A 1

TECHNICAL INFORMATION L / A 1 1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY (RATIO 1:20) Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 132 rpm 12 50 rpm 300 540 inches

More information

The paper machine is constituted by equipment manufactured by the following companies:

The paper machine is constituted by equipment manufactured by the following companies: 1) PAPER MACHINE The paper machine is constituted by equipment manufactured by the following companies: Based on following project data: - CARCANO KMW - OMMA - DE PRETTO-ESCHER-WYSS - VOITH - VALMET COMO

More information

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html

More information

AIR HANDLING THERMAL CONDITIONS

AIR HANDLING THERMAL CONDITIONS AIR HANDLING THERMAL CONDITIONS Parts of air handling unit (=AHU): Outdoor air grille Air chamber Outdoor air damper Filter Heat recovery unit Heating coil Fan Sound absorber Mixing chamber Per-heating

More information

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall

More information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information

More information

ANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd.

ANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd. ANNEXURE 1 KEY PLAN Project site Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd. 18 ANNEXURE 2 PLANT LAY-OUT Application Form 1 for Amendment in Environmental

More information

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

ECOCIAT. Domestic hot water heat recovery unit. Use. Range Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION

More information

Atlas Copco. After-coolers, water separators and drains HD 4-96 & TD 8-650, WSD & WD 80/EWD

Atlas Copco. After-coolers, water separators and drains HD 4-96 & TD 8-650, WSD & WD 80/EWD Atlas Copco After-coolers, water separators and drains HD 4-96 & TD 8-650, WSD 25-750 & WD 80/EWD 50-1500 A range of effective after-coolers and water separators to match your compressor Water-cooled HD

More information

Industrial. Solutions brands you trust. Product Overview

Industrial. Solutions brands you trust. Product Overview Industrial Solutions brands you trust. Product Overview Industrial Pump Applications Crane & Systems design s the most efficient and economical pumps to serve the large diversity of industrial applications

More information

Air Conditioning Inspections for Buildings Condensers

Air Conditioning Inspections for Buildings Condensers . Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,

More information

Biosolids Management Utilizing Solar and Thermal Processes

Biosolids Management Utilizing Solar and Thermal Processes Biosolids Management Utilizing Solar and Thermal Processes By Chris Enloe-Instrument & Supply, Inc. And Shannon Jones, P.E.-Utilities Engineer City of Fayetteville What are biosolids? Biosolids are the

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

Pre-cleaning for the CRC with Sponge Media Presented By: Ted Valoria Vice President, North America Sponge-Jet, Inc. Project TV

Pre-cleaning for the CRC with Sponge Media Presented By: Ted Valoria Vice President, North America Sponge-Jet, Inc. Project TV Pre-cleaning for the CRC with Sponge Media Presented By: Ted Valoria Vice President, North America Sponge-Jet, Inc. Project 20150207TV 2 Overview: Empire Southwest LLC (Mesa, AZ US) Sells, rents and services

More information

Chip reducer Z. Version

Chip reducer Z. Version Version 0-2018 Content Provided chip reducer with vertical chip feed... 3 V-J (single shaft with double-faced blades)... V-Z (single shaft with two-headed blades)... 5 VD-J and ZVDD-J (double shaft with

More information

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 12 CD30 PACKAGE CONTENTS Item Description Quantity 1133500 Dehumidifier 1 3014338 PVC tube 12mm I/D 3 M 3086101 Jubilee clip

More information

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

THE INITIATES PLC (TIP)

THE INITIATES PLC (TIP) THE INITIATES PLC (TIP) THERMALDESORPTION SERVICES THE INITIATES PLC TDU, Incinerator, Cleaning & Decontamination, E-waste Services Our Culture: Mission; vision; business core values OUR MISSION: To facilitate

More information

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an

More information

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar. Rotary Screw Compressors ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar www.kaeser.com ASK series ASK Maximum performance Discerning users expect

More information

Vertical self-contained air conditioner

Vertical self-contained air conditioner Compact and sleek Broad range of functions and performance Energy efficient (EC motor) and self-regulating control Easy to install ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

Operating Performance

Operating Performance INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.

More information

With the world-renowned SIGMA PROFILE

With the world-renowned SIGMA PROFILE www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor

More information

VACUUM CLEANERS TOUGH, RUGGED AND BUILT TO LAST!

VACUUM CLEANERS TOUGH, RUGGED AND BUILT TO LAST! CLEAN UP BIG AGRICULTURE /////////////// VACUUM CLEANERS TOUGH, RUGGED AND BUILT TO LAST! Amazes users with its tremendous suction power to clean up big Agriculture:» FINE DUSTS» CLUMPS OF GROWING GRAIN»

More information

EDPAC International Close Control Air Conditioning Products E

EDPAC International Close Control Air Conditioning Products E EDPAC International Close Control Air Conditioning Products E4.19-04-04-04 The Ranges of Close Control Products comprise of : Close Control Modular Range : Modular units, using R407C/R410A & Chilled Water

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

BASIL 6000 TUNNEL CAGE WASHER

BASIL 6000 TUNNEL CAGE WASHER BASIL 6000 TUNNEL CAGE WASHER APPLICATION For thorough, efficient cleaning of cages, debris pans, bottles, feeder bowls, and miscellaneous items used in the care of laboratory animals. DESCRIPTION The

More information

TMCI Padovan Evaporators

TMCI Padovan Evaporators TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product

More information