The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors.
|
|
- Scot Sherman
- 5 years ago
- Views:
Transcription
1 4. LIST OF EQUIPMENT SUPPLIED The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors. The item numbers sown correspond to the operating diagram enclosed with this tender SLUDGE RECEIVING UNIT (OPTION - SECTION 1000) Client s responsibility DRYING UNIT (SECTION 2000) Supply of dehydrated sludge The equipment supplied comprises Two twin type feed pumps Item... PO Type... eccentric rotor Supplier... WANGEN Body material... Perbunan Rotor material... V2A (stainless steel) Flow... 0,8 4,3 m 3 /h Motor output kw Maximum pressure bars Equipped with a feed hopper each with a capacity of 4,5 m 3 (item RF 2002, 2003) and a safety system to prevent running empty and excess pressure. With piping and control to permit filling of client^s cludge silos (see process flow diagram) The pipework connecting to the thin layer dryer and the sludge silos. The requisite instrumentation (see. PFD) First treatment stage A thin layer dryer Item... EF 2006 Type... horizontal, G 3 Length m Sealed... by stuffing box Transmission... belt Motor output kw Material:. Fins... Stainless steel. Stator , Dillimax 690T or similar. Rotor... Stainless steel Weight empty... Weight when operating kg kg The equipment will be constructed in accordance with the German TüV and AD- Merkblatt norms. Adaptation to any other norm will incur additional costs
2 A chopper Item... CH 2007 Type... CHP 15A Changing... Automatic Rotation speed rpm Material in contact with the sludge... Stainless steel Transmission... Belt Motor output kw Including automatic cleaning of the cutters. Compressed air (6 bars) is required for the automatic cleaning system. The Client is responsible for supplying the air compressor and the supply circuit. For ease of rinsing the sieves with water a single rail lifting device is provided by Innoplana. The area between chooper, belt dryer and rinsing station (to be supplied by the client) is being closed off the rest of the building so that the polluted air can be separately removed to the vent air. Thus another c m3/h of vent air are to be removed A steel construction to support the thin film dryer which has to be superimposed to the belt dryer (as well as the heat recovery system) with stairs and safety rails. Clearance between bottom an lower limit of steel construction c. 4.8 m. Clearance for hook of travelling crane from bottom : c 8,5m A distribution belt to the belt conveyor Item... TD 2008 Type... CHP Changing... Automatic Conveyor belt material... PVC External material... painted carbon steel (RAL 5005) and stainless steel 304 Transmission... Belt A rinsing water tank Item... RF 2030 Material:... stainless steel External material... painted carbon steel (RAL 5005) and stainless steel 304 Including the pipework between the tank and the connection to the drying unit. The Client is responsible for the rinsing water (treated effluent) supply pipe and the other systems (valves, pumps, etc.). The requisite instrumentation (see PFD)
3 Second treatment stage A belt conveyor Item... EF 2009 Number of belts... 5 Motor output (1 per belt)... 5 x 0,5 kw a crusher Item... QC 2010 Motor output... 3 kw Temperature regulation Belt dryer thermal loop A bracket-mounted recirculating fan Item... CV 2011 Material... Carbon steel Motor output kw Maximum air temperature C An exchanger for partially condensing the steam from the second stage, situated on the outlet from the belt dryer Item... EW 2021 Type... steel pipes Hot fluid... Second stage steam Material... Stainless steel An exchanger for condensing the steam from the first stage and reheating the steam from the second stage, situated on the outlet from the belt dryer Item... EW 2022 Cold fluid... Second stage steam Hot fluid... First stage steam Body material... Stainless steel Tube material... Glass An additional exchanger for reheating the second stage steam, situated on the outlet from the belt dryer Item... EW 2023 Cold fluid... Second stage steam Hot fluid... Coolant Body material... Painted carbon steel (aluminiumbronze) Tube material... Galvanised steel
4 A vent to be connected to the air treatment system; system and connection to be the Client s responsibility Cooling loop for the last dryer belt A bracket-mounted cooling air fan Item... CV 2013 Material... Carbone steel Motor output... 3kW Maximum air temperature C An exchanger for cooling the dryer s air on the last belt Item... EW 2026 Type... fine tube Hot fluid... Last dryer belt air Body material... Carbon steel Tube material... Copper / Aluminium The Client is responsible for the pipework supplying the treated effluent as far as the connection flanges on the exchanger Condensate cooling loop A recirculation pump Item... PO 2014 Motor output kw Operating temperature to 60 C An exchanger for condensing the steam and cooling the condensate Item... EW 2024 Cold fluid... Industrial water Hot fluid... First stage condensate Body material... Stainless steel 304 Tube material... Galvanised steel An exchanger for maintaining the coolant temperature Item... EW 2025 Hot fluid... Industrial water Body material... Stainless steel 304 With a bypass exchanger..ew2028 permitting to clean the main exchanger without stopping the dryer by closing/opening manual valves
5 An expansion vessel Item... RF 2020 Volume litres Material... Plastic-coated carbon steel The Client is responsible for the pipework supplying the treated effluent as far as the connection flanges on the exchanger. Heat Recovery The energy will be recovered from the cooling loop instead of temperature maintenance via exchanger EW An exchanger EW 2027 will be supplied addtionally to EW An exchanger for maintaining the coolant temperature Item... EW 2027 Cold fluid... fluid for reheating Hot fluid... Industrial water Condensate recovery Handling A condensate recovery tank Item... RF 2016 Volume... 0,7 m 3 Material... Stainless steel A bracket-mounted air extraction fan on the condensate tank for recirculating this air to the belt dryer Item... CV 2017 Material... Epoxy painted aluminium Motor output... 1,5 kw A condensate pump to enable the tank to be drained Item... PO 2018 Motor output... 0,4 kw Operating temperature C The pipework supplying the condensate to the tank and then from the tank to the drain pump. The Client is responsible for the pipework for the condensate from the drain pump, from the pump s flange. The provision of a travelling crane by the client.
AIRWASH Abrasive Recycling System
AIRWASH Abrasive Recycling System Racohi AIRWASH Abrasive Recycling System is designed & manufactured with high quality materials to be the most robust and reliable in the industry. It is an innovative
More informationMETAL CHIP AND COOLANT MANAGEMENT PLANTS
indass METAL CHIP AND COOLANT MANAGEMENT PLANTS 1 Industrie Associate s history Industrie Associate s factory 2 Production department CONVEYORS Vertical Centrifuges Wet metal swarf can contain up to 25%
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More informationBOILER HOUSE PRODUCTS GMS
GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationHalton Rex 600 Basic R6B - Active chilled beam
Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationhydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying
hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying A robust and proven design for high capacity sludge drying Sludge, the by-product of wastewater treatment, consists
More informationRoof top SPACE RPC 450Z R407C M011
Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per
More informationRefrigeration & Air Conditioning Experiment No. 5. Experiment No. 5
Refrigeration & Air Conditioning Experiment No. 5 1.0 Title of the experiment: - Experiment No. 5 Dismantling and assembly of hermetically sealed compressor. 2.0 Prior Concepts: - Compressor function in
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors
More informationSECOND HAND ASPHALT PALANT FOR SALE
. BITUMEN STORAGE DREDGING EQUIPMENT QUARRY INSTALLATIONS. Unit 1, Burnhouse Industrial Estate, Burnhouse Industrial Estate, Whitburn, West Lothian, EH47 0LQ SECOND HAND ASPHALT PALANT FOR SALE Manufacturer:
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationSteam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab
Steam Generator (Boiler) ME 268 Model Lab Aashique Alam Rezwan Lecturer Department of Mechanical Engineering, BUET, Dhaka-1000 http://teacher.buet.ac.bd/aashiquear ME 268 Aashique Alam Rezwan 1 Modern
More informationHIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%
Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and
More informationGranulators. Piovan Granulators. RSP 15 Series. PIOVAN SpA. Marketing Dept. Lucio Girardello. Mktg Dept (l&g) RSP 15-eng re.01 modification reserved
Granulators Piovan Granulators RSP 15 Series PIOVAN SpA Marketing Dept. Lucio Girardello 1 Mktg Dept (l&g) RSP 15-eng re.01 modification reserved New RSP 15 Series The new low speed RSP 15 Series is the
More informationBoretech China Make, Pet Bottles Recycling Line Ref Id SM4325 (Details-Specification mentioned hereunder are for indicative purpose only) DESIGN DATA 1.1 Capacity - PET bottles input : 1,500 kg/h - Dry
More informationCNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R
CNG PSB Industries NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R PSB Industries PSB Industries Inc., General Air Division, specializes in the Design and Fabrication of compressed
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationQuality & Service Since For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying
Quality & Service Since 1908 For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying Features & Benefits Why it will pay you to have our Metal Turnings Crusher in
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com
More informationHYDROCIAT LW R407C. Water cooled chillers USE RANGE
Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationGRP Ducting and Glass Tube Heat Exchanger Installation
2 GRP Ducting and Glass Tube Heat Exchanger Installation Don Valley Maltings Division Don Valley Engineering is the leading UK provider of Process Plant and Support to the Malting Industry, and the only
More informationHOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING
white paper HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING Better Thermal Processing Results Begin with Selecting the Right Technology Authored by Rob Grady Director of
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationPAPER MILL MANUFACTURER OF SEVERAL TYPES OF BOARDS AND PACKAGING GRADES
PAPER MILL MANUFACTURER OF SEVERAL TYPES OF BOARDS AND PACKAGING GRADES The paper mill produces papers and boards made with wood pulp and with recycled fibers. Production includes file folder grades and
More informationZD Tunnel Inline Cleaning Systems suginocorp.com Zippel GmbH
The ZD Series is our innovative response to the increasing diversity of parts requiring conveyor, chain, or fixtured in-line washing systems. Zippel through-feed cleaning machines can be custom-fit to
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationCommercial Hot Water Solutions Ltd.
FOR THE SUPPLY OF: Hot Water Generators Single & Twin Coil Vessels Buffer Vessels Gas Fired Continuous Flow Water Heaters with Buffer Storage www.chwsltd.co.uk CHWS Ltd provides specialist services for
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationFLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.
The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly
More informationTREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias
TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW Rohde, Mathias Content 1. Types of radioactive residuals 2. Treatment and conditioning facilities 3. Storage of radioactive
More informationSavile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h
Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame
More informationAIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING
AIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING CHEMICAL PLANTS CURING ROOMS DRYING KILNS FACTORIES GASIFICATION PLANTS GREENHOUSES PAPER MILLS
More informationASPHALT PLANT. atlastechnologiesindia.com
ASPHALT PLANT MOBILE PLANT VARIANT: MDM 25 (20-30 tph) atlastechnologiesindia.com AGGREGATE FEEDING CONVEYOR AGGREGATE FEEDER In our mobile asphalt drum mix plant all the four bins are fitted with individual
More informationRoof top SPACE RPC 315Z R407C MA00
Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,
More informationSAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts
Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products
More informationIntroduction to AD-Engineering - Plant components I. R. Waltenberger, R. Kirchmayr
Introduction to AD-Engineering - Plant components I R. Waltenberger, R. Kirchmayr Reactor mixing - Mixing of fresh substrate with digester sludge - Even distribution of heat in the fermenter - Distribution
More informationAir Handling Units. Real HVACR people who understand your needs.
Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering
More informationEBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationTopMaster Air Handling unit. Installation instructions
Installation instructions Safety Instructions Operation of Air Handling units and accessories WARNING Installation may only be carried out by qualified personnel. Before taking the air handling unit into
More informationInformation on Feeder Systems ProMinent Australia
Information on Feeder Systems ProMinent Australia Powders that ProMinent have provided packages for: Sodium fluoride Sodium silicofluoride PAC Soda ash Lime Alum Potassium permanganate Calcium Hypochlorite
More informationAlfa Laval Wet Surface Air Coolers (WSAC ) FAQs
Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Q: How is the WSAC a closed-loop cooling system? A: The WSAC is a closed-loop cooling system because the process loop being cooled is inside the tube bundles
More informationCoal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business
Coal Handling and Processing Advanced Solutions for Coal-Related Environmental Dust Control Better Air is Our Business Coal Handling and Processing Industry Leader Our Qualifications For more than 85 years,
More informationMetropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h
Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure
More informationHalton Rex for Vario R6O - Variable air volume chilled beam
Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationSR10. Rotative blowing for large mass productionof packagings from 0,1 L to 0,75 L
SR10 Rotative blowing for large mass productionof packagings from 0,1 L to 0,75 L SR10 PRODUCTION : Maxi Dimensions : Closing force : 0,7 T Volume : 750 cm3 Height : 195 mm Diameter : 100 mm MAXIMUM USUAL
More informationPUMPKIN SEED HARVESTING TECHNOLOGY 2019
PUMPKIN SEED HARVESTING TECHNOLOGY 2019 Moty GmbH Piesing 20, AT 4846 Redlham office@moty.at www.moty.at Engineering changes, literal mistakes and prices are subjects to change Your reliable partner for
More informationB. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.
PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationPELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian
PELLET MILL N-MIDI pellet mill machine is projected and manufactured in accordance with CE norm about construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationVEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.
Slim design and acoustic comfort Saves up to 40% floor space Capacity up to 50 kw Free cooling Water misting Use Drycoolers in this range are mainly designed for cooling water or glycol/water mix for:
More informationTechnical Specification
Cochran Ltd Newbie Works, Annan, Dumfries & Galloway, Scotland, UK DG12 5QU Telephone: +44 (0)1461 202111 Fax: +44 (0)1461 205511 Email: info@cochran.co.uk www.cochran.co.uk COCHRAN HEAT RECOVERY Package
More informationVERSO Air Handling Units
VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P
More informationLiquid Ring Vacuum Pumps, Compressors and Systems
Helmut Bannwarth Liquid Ring Vacuum Pumps, Compressors and Systems Conventional and Hermetic Design Translated by Christine Ahner WILEY- VCH WILEY-VCH Verlag GmbH & Co. KGaA XIII Foreword VII Preface IX
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)
ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors
More informationEKK Anlagentechnik. Plastics and Environmental Technology. Update 01/2018. certified acc. to ISO 9001 ISO 14001
EKK Anlagentechnik Plastics and Environmental Technology Contents Company portrait company sites manufacturing Scope of services planning production installation service / maintenance quality management
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationShyam Enterprises 9 PACKAGE UNIT
Shyam Enterprises 9 PACKAGE UNIT 59 Reaction Distillation Unit The Unit has been designed to suit the customers requirement of combination of versatile reaction/distillation or combination for pilot plant
More informationTECHNICAL INFORMATION L / A 1
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY (RATIO 1:20) Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 132 rpm 12 50 rpm 300 540 inches
More informationThe paper machine is constituted by equipment manufactured by the following companies:
1) PAPER MACHINE The paper machine is constituted by equipment manufactured by the following companies: Based on following project data: - CARCANO KMW - OMMA - DE PRETTO-ESCHER-WYSS - VOITH - VALMET COMO
More informationCR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ
GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html
More informationAIR HANDLING THERMAL CONDITIONS
AIR HANDLING THERMAL CONDITIONS Parts of air handling unit (=AHU): Outdoor air grille Air chamber Outdoor air damper Filter Heat recovery unit Heating coil Fan Sound absorber Mixing chamber Per-heating
More informationCLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements
Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall
More informationAGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE
INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information
More informationANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd.
ANNEXURE 1 KEY PLAN Project site Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd. 18 ANNEXURE 2 PLANT LAY-OUT Application Form 1 for Amendment in Environmental
More informationECOCIAT. Domestic hot water heat recovery unit. Use. Range
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION
More informationAtlas Copco. After-coolers, water separators and drains HD 4-96 & TD 8-650, WSD & WD 80/EWD
Atlas Copco After-coolers, water separators and drains HD 4-96 & TD 8-650, WSD 25-750 & WD 80/EWD 50-1500 A range of effective after-coolers and water separators to match your compressor Water-cooled HD
More informationIndustrial. Solutions brands you trust. Product Overview
Industrial Solutions brands you trust. Product Overview Industrial Pump Applications Crane & Systems design s the most efficient and economical pumps to serve the large diversity of industrial applications
More informationAir Conditioning Inspections for Buildings Condensers
. Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,
More informationBiosolids Management Utilizing Solar and Thermal Processes
Biosolids Management Utilizing Solar and Thermal Processes By Chris Enloe-Instrument & Supply, Inc. And Shannon Jones, P.E.-Utilities Engineer City of Fayetteville What are biosolids? Biosolids are the
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationPre-cleaning for the CRC with Sponge Media Presented By: Ted Valoria Vice President, North America Sponge-Jet, Inc. Project TV
Pre-cleaning for the CRC with Sponge Media Presented By: Ted Valoria Vice President, North America Sponge-Jet, Inc. Project 20150207TV 2 Overview: Empire Southwest LLC (Mesa, AZ US) Sells, rents and services
More informationChip reducer Z. Version
Version 0-2018 Content Provided chip reducer with vertical chip feed... 3 V-J (single shaft with double-faced blades)... V-Z (single shaft with two-headed blades)... 5 VD-J and ZVDD-J (double shaft with
More informationCD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 12 CD30 PACKAGE CONTENTS Item Description Quantity 1133500 Dehumidifier 1 3014338 PVC tube 12mm I/D 3 M 3086101 Jubilee clip
More informationPOWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings
POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationTHE INITIATES PLC (TIP)
THE INITIATES PLC (TIP) THERMALDESORPTION SERVICES THE INITIATES PLC TDU, Incinerator, Cleaning & Decontamination, E-waste Services Our Culture: Mission; vision; business core values OUR MISSION: To facilitate
More informationEBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an
More informationRotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.
Rotary Screw Compressors ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar www.kaeser.com ASK series ASK Maximum performance Discerning users expect
More informationVertical self-contained air conditioner
Compact and sleek Broad range of functions and performance Energy efficient (EC motor) and self-regulating control Easy to install ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling
More informationOperating Performance
INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.
More informationWith the world-renowned SIGMA PROFILE
www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor
More informationVACUUM CLEANERS TOUGH, RUGGED AND BUILT TO LAST!
CLEAN UP BIG AGRICULTURE /////////////// VACUUM CLEANERS TOUGH, RUGGED AND BUILT TO LAST! Amazes users with its tremendous suction power to clean up big Agriculture:» FINE DUSTS» CLUMPS OF GROWING GRAIN»
More informationEDPAC International Close Control Air Conditioning Products E
EDPAC International Close Control Air Conditioning Products E4.19-04-04-04 The Ranges of Close Control Products comprise of : Close Control Modular Range : Modular units, using R407C/R410A & Chilled Water
More informationTECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS
TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM
More informationBASIL 6000 TUNNEL CAGE WASHER
BASIL 6000 TUNNEL CAGE WASHER APPLICATION For thorough, efficient cleaning of cages, debris pans, bottles, feeder bowls, and miscellaneous items used in the care of laboratory animals. DESCRIPTION The
More informationTMCI Padovan Evaporators
TMCI Padovan Evaporators Evaporators Our range includes 4 types of evaporators: Forced Circulation Falling Film Evaporators Plates Thin Film Concentration systems Evaporator choosing criteria: product
More information