Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
|
|
- Cathleen Barnett
- 5 years ago
- Views:
Transcription
1 Amendment Sheet Code : M5ACV Date : Superceded : M5ACV Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : V/1Ph/50Hz F : V/3Ph/50Hz M 5 AC V 100 C R - F X AA Model Type R : heatpump Omitted if cooling Series C : C series Capacity 100 : 100,000 Btu/h Type Inverter Model Name AC : Air cooled mini chiller Refrigerant 5 : R410A Brand McQuay
2 Product Line-up M5ACV Product line-up Classification Heat pump model Nomenclature Wired handset WCCH Gold Fin Isolator Switch Terminal block Scroll compressor capillary tube (normal circuit) EXV (Inverter circuit) Pump only Brass adaptor BSPT 1 1/4 Brass adaptor BSPT 1 030CR AXAA X X X X X X X 055CR FXAA X X X X X X X M5ACV 075CR FXAA X X X X X X X 100CR FXAA X X X X X X X X 135CR FXAA X X X X X X X X
3 Specifications General Data - Heat pump R410A Inverter NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT POWER SOURCE REFRIGERANT CONTROL UNIT DIMENSION PACKING DIMENSION UNIT WEIGHT SOUND PRESSURE LEVEL EVAPORATOR Btu/h W Btu/h W COOLING W 9050 HEATING W 7900 COOLING A 16.6 HEATING A 15.4 V/Ph/Hz / 3 / 50 R410A ELECTRONIC EXPANSION HEIGHT mm/in 1460 / 57.5 WIDTH mm/in 1150 / 45.3 DEPTH mm/in 550 / 21.7 HEIGHT mm/in 1626 / 64.0 WIDTH mm/in 1309 / 51.5 DEPTH mm/in 656 / 25.8 kg/lb 200 / 440 dba 65 NOMINAL WATER FLOW COOLING l/s / m 3 /hr 0.9 ( 3.4 ) HEATING l/s / m 3 /hr 1.0 ( 3.7 ) CONDENSER FAN /DRIVE QUANTITY PROPELLER / DIRECT 2 HYDRAULIC KIT HORIZONTAL MULTISTAGE END-SUCTION MAX. WATER OPER. PRESSURE kpa / psi 1000 / 145 PUMP COOLING l/s / m 3 /hr 0.9 ( 3.4 ) WATER FLOW RATE HEATING l/s / m 3 /hr 1.0 ( 3.7 ) INSTALLATION PIPE CONNECITON mm/in 25.4 / 1 PIPING COOLING m 22.3 HEAD HEATING m 21.3 TANK MATERIAL NOT APPLICABLE CAPACITY/VOLUME L / ft 3 NOT APPLICABLE COMPRESSOR STAGE OF CAPACITY CONTROL (Btu/h) SCROLL REFRIGERANT CHARGING MASS kg/lb 4.8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO ) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12 C / 7 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35 C AIR AMBIENT TEMPERATURE. b) HEATING - 40 C / 45 C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7 C AIR AMBIENT TEMPERATURE. 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
4 Electrical Data - Heat pump R410A Inverter CONDENSER FAN MOTOR COMPRESSOR WATER PUMP INSULATION GRADE B POWER SOURCE V/Ph/Hz / 1 / 50 RATED INPUT POWER W 300 x2 RATED RUNNING CURRENT A 1.5 x2 MOTOR OUTPUT POLES INSULATION GRADE W 145 x2 8 E POWER SOURCE V/Ph/Hz / 3 / 50 CAPACITOR μf NA RATED INPUT POWER (COOLING) W 7700 RATED INPUT POWER (HEATING) W 6500 RATED RUNNING CURRENT (COOLING) A 14.3 RATED RUNNING CURRENT (HEATING) A 13.1 LOCKED ROTOR AMP. INSULATION GRADE A NA F POWER SOURCE V/Ph/Hz / 3 / 50 RATED INPUT POWER (COOLING) W 750 RATED INPUT POWER (HEATING) W 800 RATED RUNNING CURRENT (COOLING) A 1.3 RATED RUNNING CURRENT (HEATING) A 1.4 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
5 Safety Devices SAFETY DEVICE NC HIGH PRESSURE SWITCH OPEN Pa / psi 600 CLOSE Pa / psi 480 NC LOW PRESSURE SWITCH OPEN Pa / psi 18 CLOSE Pa / psi 28 PHASE PROTECTION BUILT IN ON BOARD DIFFERENTIAL PRESSURE SWITCH YES ANTI-FREEZE PROTECTION SENSOR YES DISCH. THERMOSTAT SETTING C / F 110 / 230 OVER PRESSURE RELIEF YES ANTI-FREEZE HEATER ON BPHE PUMP OLP COMPRESSOR OLP YES YES YES 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
6 Components Data CONDENSER FAN CONDENSER FAN MOTOR COMPRESSOR CONDENSER COIL BPHE PUMP CASING Q'TY MATERIAL DRIVE PROPELLER 2 ALUMINIUM DIRECT DIAMETER Q'TY INDEX OF PROTECTION (IP) OIL mm/in / 24 INDUCTION 2 NA AC INVERTER SCROLL POE MATERIAL OIL INVERTER AMOUNT SCROLL cm 3 / fl.oz / 77.8 CROSS FINNED TUBES INNER GROOVED COPPER TUBE DIAMETER mm/in 9.52 / 3/8 THICKNESS MATERIAL mm/in / CORRUGATED ALUMINIUM THICKNESS mm/in 0.12 / FIN MATERIAL MATERIAL MATERIAL COLOUR FACE AREA ROW FIN PER INCH m 2 / ft / BRAZED PLATE HEAT EXCHANGER STAINLESS STEEL HORIZONTAL MULTISTAGE END-SUCTION CAST IRON & STAINLESS STEEL ELECTRO-GALVANIZED MILD STEEL LIGHT GREY- PE ) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
7 Sound Data Sound Pressure Level Model 1/1 Octave Sound Pressure Level (db, ref 20μPa) Overall 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz (dba) M5ACV030CR M5ACV055CR M5ACV100CR M5ACV135CR Tested according to JIS B 8615 & JIS C Microphone position : 1m from each side Sound Power Level Model 1/1 Octave Sound Power Level (db, ref 1pW) Overall 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz (dba) M5ACV030CR M5ACV055CR M5ACV100CR M5ACV135CR Tested according to ISO 3741 Model Measuring location (for Sound Pressure Level) M5ACV030CR M5ACV055CR M5ACV135CR M5ACV100CR 1m 1m 1m 1m 1m 1m Standard : JIS B 8615, JIS C 9612 Microphone position : 1m from each side
8 Performance Tables Model : - Cooling LEAVING WATER TEMP ( C) AMBIENT TEMPERATURE ON CONDENSOR ( C) WATER AVAIL. PUMP PUMP COOL POWER RUNNING COOL POWER RUNNING COOL POWER RUNNING COOL POWER RUNNING FLOW HEAD INPUT INPUT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP kw kw A kw kw A kw kw A kw kw A m 3 /hr kpa W A LEAVING WATER TEMP ( C) AMBIENT TEMPERATURE ON CONDENSOR ( C) WATER AVAIL. PUMP PUMP COOL POWER RUNNING COOL POWER RUNNING COOL POWER RUNNING COOL POWER RUNNING FLOW HEAD INPUT INPUT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP kw kw A kw kw A kw kw A kw kw A m 3 /hr kpa W A LEAVING WATER TEMP ( C) AMBIENT TEMPERATURE ON CONDENSOR ( C) WATER AVAIL. PUMP PUMP COOL POWER RUNNING COOL POWER RUNNING FLOW HEAD INPUT INPUT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP kw kw A kw kw A m 3 /hr kpa W A
9 Model : - Heating LEAVING WATER TEMP ( C) AMBIENT TEMPERATURE ON CONDENSOR ( C) WATER AVAIL. PUMP PUMP HEAT POWER RUNNING HEAT POWER RUNNING HEAT POWER RUNNING FLOW HEAD INPUT INPUT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP kw kw A kw kw A kw kw A m 3 /hr kpa W A LEAVING WATER TEMP ( C) AMBIENT TEMPERATURE ON CONDENSOR ( C) WATER AVAIL. PUMP PUMP HEAT POWER RUNNING HEAT POWER RUNNING HEAT POWER RUNNING FLOW HEAD INPUT INPUT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP kw kw A kw kw A kw kw A m 3 /hr kpa W A LEAVING WATER TEMP ( C) AMBIENT TEMPERATURE ON CONDENSOR ( C) WATER AVAIL. PUMP PUMP HEAT POWER RUNNING HEAT POWER RUNNING FLOW HEAD INPUT INPUT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP kw kw A kw kw A m 3 /hr kpa W A
10 Technical Data Water Pressure Drop vs Flow Rate Model : - Cooling Water Flow m 3 /hr Pump Head kpa System Head kpa Available Head Presure kpa
11 Outline Dimensions Model :
12 Figure 11 5ACV 30 CR WATER / REFRIGERANT CIRCUIT DIAGRAM EXV FILTER DRIER BPHE CHARGE COMPENSATOR WATER OUT COMPRESSOR SUCTION ACCUMULATOR WATER IN EXPANSION TANK P WATER PUMP Figure 12 5ACV 55 CR / 75 CR WATER / REFRIGERANT CIRCUIT DIAGRAM FILTER DRIER EXV BPHE WATER OUT LIQUID RECEIVER SUCTION ACCUMULATOR COMPRESSOR WATER PUMP P EXPANSION TANK WATER IN xi
13 M5ACV075 CR Figure 3 PART NO : v
14 Figure 4 577,0 577,0 372,0 5ACV 30 CR 5ACV 55 CR 5ACV 75 CR Figure 5 HANGER HANGING BELT HANGER HANGING BELT 5ACV 55 CR 5ACV 75 CR vi
15 Figure MIN Figure Figure MIN 500 vii
16 5ACV 30 CR 5ACV 55 CR / 75 CR
17 Figure 10 5ACV 30 CR PRESSURE GAUGE AIRVENT (INSTALL HIGHEST POSITION) GATE GATE THERMOMETER GATE BALANCING THERMOMETER GATE BALANCING GATE FAN COIL UNIT/AIR HANDLING UNIT BYPASS P (DIFFER ENT PRESSURE ) FLEXIBLE STRAINER CHECK GATE (LOWER POSITION FOR DRAINAGE) MAKE UP 5ACV 55 CR / 75 CR PRESSURE GAUGE AIRVENT (INSTALL HIGHEST POSITION) GATE GATE THERMOMETER GATE BALANCING THERMOMETER GATE BALANCING GATE FAN COIL UNIT/AIR HANDLING UNIT BYPASS P (DIFFER ENT PRESSURE ) FLEXIBLE STRAINER CHECK GATE (LOWER POSITION FOR DRAINAGE) MAKE UP x
18 Electrical wiring Refer to the wiring diagram provided on the unit when making electrical wiring. Do not ground any electrical equipment to the water piping. Install an external isolator switch (if it is not provided) to prevent electrical shock. Recommended fuse and cable sizes Model 5ACV030CR 5ACV055/075CR Voltage Range ** 230 / 1 / / 3 /50 Recommended Fuse * A / 36 Power Supply Cable Size * mm / 10 Number of Conductor 3 5 / 5 Interconnection Cable Size * mm / 1.5 IMPORTANT : * The figures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also subjected to the type of installation and conductors used. ** The appropriate voltage range should be checked with label data on the unit.! CAUTION All field wiring must be installed in accordance with the national wiring regulation. All the terminals and connections must be tightened. Improper connection and fastenings could cause electric shock, short circuit and fire. Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram. The unit must be GROUNDED to prevent possible hazards due to insulation failure. All electrical wiring must not touch the refrigerant piping, compressor, pump, fan motor or any moving parts of the fan motors. Do not operate the chiller with wet hands. It would result in electric shock. Do not use fuse of different amperage than stated. Using wire etc. to replace a fuse could cause equipment damage or fire.
19 Exploded View Model : No Description Part no No Description Part no 1 ASSY, BASE PAN ASSY, STRUCTURE REAR RIGHT ASSY, PANEL PARTITION COIL GUARD, BACK ASSY, COIL COIL GUARD RIGHT COMP. ASSY ANV47FKBMT ASSY, INS. PANEL TOP ASSY, BPHE ASSY, BRACKET MOTOR SUPPORT, ACCU., & LIQUID RECEIVER MOTOR LIQUID RECEIVER FAN BLADE INS, LIQUID RECEIVER STRUCTURE, FRONT BODY RIGHT BOTTOM ACCUMULATOR FAN BLADE INS, ACCUMULATOR BODY SUPPORT, MOTOR BRACKET FILTER DRIER REACTOR - 12 CLAMP, BPHE PANEL, COVER REACTOR CLIP, FILTER DRIER ASSY, TERMINAL BOX MAIN ASSY, PUMP BASE ASSY, COVER TERMINAL BOX PLATE, PUMP SUPPORT SCREW, M4x WATER PUMP CH4-40(AUUE) SCREW, M5x EXPANSION TANK 5L SCREW, 5x CLAMP, EXPANSION TANK SCREW, TRUSS HEAD PRESSURE RELIEF BOLT HEX M8x ASSY, WATER PIPING WASHER SPRING PANEL, SUPPORT PILLAR NUT, C/W FLANGE M ASSY, PANEL ORIFICE RUBBER GROMMET - 23 ASSY, PANEL RIGHT (MAIN) SPACER - 24 ASSY, STRUCTURE FRONT RIGHT TOP SCREW, PHILIP PAN HEAD ASSY, UNIT TUBING WASHER, SPRING PANEL, SIDE LEFT WASHER, FLAT
2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.
2. FEATURES TRUE DUAL CIRCUITS BPHE The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel
More informationModels: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)
Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 10 CR A5ACV - 007 Air-Cooled Chiller (R410A Inverter Series) 1. NOMENCLATURE Production spec variation Type of ref. connection
More informationModels: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems
Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...
More informationAir-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161
Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR Air-Cooled Mini Chiller Manual No: TMA-AMAC-1161 REGISTERED ISO 9002 CONTENTS PAGE 1. NOMENCLATURE SYSTEM...
More informationWall Mounted Split Systems
MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11
More informationHorizontal Water Source Heat Pumps And Cooling Only Unit
MWH-B-2005 Horizontal Water Source Heat Pumps And Cooling Only Unit Models: MWH MWH MWH MWH MWH 011 B/BR MWH 012 B/BR MWH 015 B/BR MWH 020 B/BR MWH 025 B/BR MWH 030 B/BR 040 B/BR 050 B/BR 060 B/BR 070
More informationINVERTER Y SINGLE SPLIT SERIES II
TECHNICAL MANUAL -0005 Supercedes -0004 INVERTER Y SINGLE SPLIT SERIES II Models: M5CKY28ER M5CCY28CR M5CMY28ER M5CKY40ER M5CCY38CR M5CMY40ER M5CKY50ER M5CCY50CR M5CMY50ER M5CCY60CR M5CMY62CR Table of
More informationContents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79
MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary
More informationModels: A5HDC20AR A5HDC25AR. Horizontal Ducted Condensing Unit
Models: A5HDC20AR A5HDC25AR Horizontal Ducted Condensing Unit A5HDC-2009 A5HDC-2009 Table of Contents Table of Contents Nomenclature...2 Indoor Unit...2 Outdoor Unit...3 Product Line-Up...4 Features...6
More informationkw MRT150C Coming MRT180C MRT240C MRT300C
Dear Valued Customers, From: Lim Chin Heng (Engineer, Global UP Product Marketing, OYLM) Date (14-Feb-2012) SUBJECT: Rooftop C Series Launching of R22 High Energy Efficiency Rooftop C-Series RT180C With
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationProduct Features Technical Training 2007
Product Features Product Features Less foot print occupied Less space required. Product Features Made of AISI 316 Stainless Steel High heat exchange efficiency Product Features New Technology BPHE True
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationYour Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED
Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationHighly Efficient,Powerful Heating and Cooling.
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2
More informationPart 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...
MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationDUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................
More informationTECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:
TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA
More informationCeiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)
Technical Manual Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz) Models: MCW1400 MCW1600 Air Flow: 2270-3020m3/h MCW1800 Engineered for flexibility and performance. TM MCW-C/F(High
More informationAPPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A
No. :WXXS-000-GGSY-12 APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR MODEL C-SBR180H16A NO. DATE PAGE REVISION DETAILS SANYO SIGNED CLIENT SIGNED REVISION RECORD USER: MANUFACTURER: DALIAN
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationR22 air-cooled modular chiller 50Hz unit. Content
Content 1.Nomenclature... 2 2.Product Schedule... 2. External Appearance... 4.Features... 4 5.Specification... 6 6.Dimension... 10 7.Refrigeration System Sketch Drawing... 14 8.Wiring Diagrams... 16 9.Electric
More informationtechnical data Fan coil unit FWB small duct unit
technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------
More informationWater Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL
Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationRoom Air Conditioner Service and Parts Manual
Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationAir cooled industrial chillers
Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More informationCMS1402 SERVICE PARTS
This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of
More informationR407C TECHNICAL MANUAL. Packaged Air Conditioner Rooftop A series. UATP-A and UATYP-A Series. Cooling only & Heatpump [50Hz]
R407C TECHNICAL MANUAL Packaged Air Conditioner Rooftop A series UATP-A and UATYP-A Series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Product Line-Up...2 Application
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationAir-Cooled Mini Chiller and Heat Pump
Product, Installation and Operation Manual 309 B/C 03/03 A Date: March 2003 Supersedes: none Air-Cooled Mini Chiller and Heat Pump M4AC 080 150 C Cooling capacity from 22,4 to 40,0 M4AC 080 150 CR Cooling
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationSELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS
SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION
More informationMAC-A R410A Series Air cooled Modular Chiller
Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationAQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING
Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationN4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationChilled Water System. All Product Brochure
Chilled Water System All Product Brochure About Acson International With products available in more than 55 countries spread across 7 continents around the world, Acson is truly international. Backed by
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationSPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB
More information500 EX Fusion Compressor Series
500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationPart 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45
Contents Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 The specifications, designs, and information in this book are subject to change without notice for product improvement.
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationMHW Air Handling Unit (50/60Hz)
Technical Manual MHW Air Handling Unit (50/60Hz) MHW015A MHW025A MHW035A MHW050A MHW020A MHW030A MHW040A Engineered for flexibility and performance. TM MHW - 2011 (50Hz/60Hz) Contents Literature No.: TM-MHW-1101A
More informationE U R O V E N T CERTIFIED PERFORMANCE
Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationКомпрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.
1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085
More information30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient
PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme
More informationModular Air Cooled Chiller
Technical Manual MAC - 2012 Modular Air Cooled Chiller Models: MAC160A/AR MAC210B/BR MAC260B/BR Refrigerant Type: R22 Cooling Capacity: 46/6/78kW Heating Capacity: 57/66/82kW Contents Literature No.: TM-MAC-1201A
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationWCH5**4. Product Specifications
HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY
More informationModels: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II Inverter Y Single Split Series II
Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II - 2010 Inverter Y Single Split Series II Table of Contents A5LCY-II-2010 Table of Contents Nomenclature...1 Indoor Unit...1 Outdoor Unit...2
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationProduct Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C
Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationN4H4. Product Specifications
14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors
More informationPUHZ-SHW140YHA PUHZ-SHW230YKA
1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE726SCL AE752SCL AE71SCL3 AE735SCL AE752SCL3 AE100SCL3 AE764SCL3 AE125SCL3 SPLIT SYSTEM AIR CONDITIONER Model No. AE726SCL AE735SCL AE752SCL AE752SCL3 AE764SCL3
More informationRoom Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02
Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE
More informationMINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)
MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw) CL25610 to CL25615 English Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components...
More informationFLOOR CONSOLE / UNDER CEILING DUAL type
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT
More informationImage Key Part Number Description Substitution Qty.
Model Number: BOM/Serial #: Graphic Title: XRSR465BW PXRSR465BW0 SUPPLEMENTAL INFORMATION Image Key Part Number Description Substitution Qty. 1 1 67002385 HARNESS-CONTROL 1 1 1 67002384 HARNESS, ICE MAKER
More informationFLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...
More information30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation
Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed
More information[U] Serie MHB / MHA Manual de Ingeniería
[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance
More informationSpare parts catalogue
Spare parts catalogue 0020117283_00 GB 08/2011 Air water heat pump geotherm air geotherm VWL 45/1 A 230 V geotherm VWL 65/1 A 230 V geotherm VWL 75/1 A 230 V geotherm VWL 125/1 A 230 V geotherm VWL 155/1
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationAdvance Split
Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.
More informationPackaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only
ED 40-437 Packaged Air Conditioners Duct Connection Type [50Hz] (Middle Static Pressure Application) FDMG-AV1(S) Series Cooling Only ED40-437 Duct Connection Type Middle Static Pressure Application [50Hz]
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationCHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION
CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION PART NUMBER BY CAPACITY 9/12 15 18/24 30 36/42 48 1 1 FRONT PANEL W/LOUVER 550-373 550-373 550-374 550-374 550-388
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More information