MAXI-VENT Air Admittance Valve

Size: px
Start display at page:

Download "MAXI-VENT Air Admittance Valve"

Transcription

1 MAXI-VENT Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 3 or 4 Model #: MAXI VENT Item #: An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent, island fixture vent, vent stack or stack vent that is provided to prevent siphonage of a fixture trap. An air admittance valve can be used as an alternative to extending a vent through the roof (or sidewall) to the open atmosphere. A. The MAXI-VENT shall be located a minimum of 4 above horizontal branch drain or fixture drain being vented and 6 above the flood level of the highest fixture for stack venting. B. Each valve should be installed in an accessible location. A. The valve should be connected to the piping in accordance with the manufacturer s installation instructions. B. The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed in a non-neutralized special (chemical) waste system or in supply and return air plenums. E. The valve may be installed on sewer ejectors, if installed according to engineer design and prior local code approval. F. For installation in areas with temperature range between 40 and 150 F. A. Screening on the inside and outside of the valve to protect the sealing membrane from insects and debris. B. Protective cover for additional insulation against extreme temperatures. C. Ability to divert condensation away from sealing membrane. D. Limited lifetime warranty for replacement of defective valves. A. Styrofoam cover B. ABS (acrylonitrile butadiene styrene) valve with silicone membrane C. Rubber connector ANSI/ASSE 1051 A&B 2009 single fixture and branch type AAVs ANSI/ASSE stack type AAVs NSF Standard Plastics Piping System and Components International Plumbing Code (IPC) International Residential Code (IRC) Uniform Plumbing Code (UPC Section Alternative Materials and Methods National Standard Plumbing Code (NSPC) - Appendix E National Plumbing Code of Canada (NPC) Listings: 5-1/4 MAXI VENT Horizontal Branch Size Stack Size 4⅞ 3 4 Push-Fit Connector

2 MAXI-CAP Manufacturer: Studor, Inc. Item #: The MAXI-CAP can be installed on MAXI-VENT in outdoor installations to protect MAXI-VENTs from damaging UV Rays and extreme temperatures. MAXI CAP 6 ⅞ A. Fits over the MAXI-VENT and styrofoam cover. If desired, paint cap prior to installation. B. Attach syrofoam to cap of valve with double-sided adhesive. C. Attach metal cap to styrofoam with double-sided adhesive. D. Ensure that one open vent pipe is maintained. 3⅝ A. Spun Aluminum Cap B. 2 pieces of double-sided adhesive Double side adhesive

3 MINI-VENT Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 1 1/2 2 Model #: MINI VENT Item #: (PVC Connector); (ABS Connector) An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent, island fixture vent, vent stack or stack vent that is provided to prevent siphonage of a fixture trap. An air admittance valve can be used as an alternative to extending a vent through the roof (or sidewall) to the open atmosphere. A. The MINI-VENT shall be located a minimum of 4 above the horizontal branch drain or fixture drain being vented and a minimum of 6 above the flood level of the highest fixture for stack venting. B. Each valve should be installed in an accessible location. A. The valve should be connected to the piping in accordance with the manufacturer s installation instructions. B. The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed in non-neutralized special (chemical) waste system or in supply and return air plenums. E. The valve may be installed on sewer ejectors, if installed according to engineer design and prior local code approval. F. For installation in areas with temperature range between 40 and 150 F. A. Screening on the inside and outside of the valve to protect the sealing assembly from insects and debris. B. Protective cover for the air intake and additional insulation against extreme temperatures. C. Ability to divert condensation away from sealing membrane. D. Limited lifetime warranty for replacement of defective valves. A. Polystyrene B. ABS (acrylonitrile butadiene styrene) valve with silcone membrane C. ABS or PVC (adaptor) ANSI/ASSE 1051 A&B single fixture and branch type AAVs ANSI/ASSE 1050 stack type AAVs NSF Standard 14 Plastics Piping System and Components 2⅝ MINI VENT Protec ve Cover 2 Adaptor 1 ½ NPT Fits 1 ½ or 2 pipe sizes International Plumbing Code (IPC) International Residential Code (IRC) Uniform Plumbing Code (UPC Section Alternative Materials and Methods National Standard Plumbing Code (NSPC) Appendix E National Plumbing Code of Canada (NPC) Listings: Horizontal Branch Size 1 1/ Stack Size 1 1/

4 REDI-VENT Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 1 1/2 or 2 Model #: REDI VENT Item #: (PVC Connector); (ABS Connector) An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent and island fixture vent that is provided to prevent siphonage of a fixture trap. An air admittance valve can be used as an alternative to extending a vent through the roof (or sidewall) to the open atmosphere. A. The REDI-VENT shall be located a minimum of 4 above the horizontal branch drain or fixture drain being vented and a minimum of 6 above the flood level of the highest fixture for stack venting. B. Each valve should be installed in an accessible location. A. The valve should be connected to the piping in accordance with the manufacturer s installation instructions. B. The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed in non-neutralized special (chemical) waste system or in supply and return air plenums. E. For installation in areas with temperature range between 40 and 150 degrees F. A. Screening on the inside and outside of the valve to protect the sealing assembly from insects and debris. B. Will vent up to 20 DFUs on a horizontal branch. C. Limited lifetime warranty for replacement of defective valves. A. ABS (acrylonitrile butadiene styrene) valve with silicone membrane B. ABS or PVC (adaptor) 2⅝ REDI VENT 2 Adaptor 1 ½ NPT Fits 1 ½ or 2 pipe sizes ANSI/ASSE single fixture and branch type AAVs ANSI/ASSE stack type AAVs NSF Standard Plastics Piping System and Components Horizontal Branch Size International Plumbing Code (IPC) International Residential Code (IRC) Uniform Plumbing Code (UPC Section Alternative Materials and Methods National Standard Plumbing Code (NSPC) Appendix E National Plumbing Code of Canada (NPC) 1 1/ Stack Size 1 1/2 8

5 AAV-TEE Redi Vent Air Admittance Valve with Tubular Adaptor Manufacturer: Studor, Inc. Connec on Size: 1½ Model #: AAV TEE Item #: An air admittance valve shall be acceptable as a vent terminal for any individual vent, common vent, circuit vent, loop vent and island fixture vent that is provided to prevent siphonage of a fixture trap. An air admittance valve can be used as an alternative to extending a vent through the roof (or sidewall) to the open atmosphere. A. The air admittance valve shall be located a minimum of 4 above the horizontal branch drain or fixture drain being vented. B. Each valve should be installed in an accessible location. A. The valve should be connected to the piping in accordance with the manufacturer s installation instructions. B. The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed in non-neutralized special (chemical) waste system or in supply and return air plenums. E. For installation in areas with temperature range between 40 F and 150 F. A. Screening on the inside and outside of the valve to protect the sealing assembly from insects and debris. B. Will vent up to 20 DFUs on a horizontal branch C. Limited lifetime warranty for replacement of defective valves. A. ABS (acrylonitrile butadience styrene) valve with silicone membrane B. Tubular adaptor (Polypropylene) ANSI/ASSE single fixture and branch type AAVs ANSI/ASSE stack type AAVs NSF Standard Plastics Piping System and Components International Plumbing Code (IPC) International Residential Code (IRC) Uniform Plumbing Code (UPC Section Alternative Materials and Methods National Standard Plumbing Code (NSPC) Appendix E National Plumbing Code of Canada (NPC) Tubular Adaptor 4 1/4 REDI VENT 2 Listings: 2⅝

6 Trap-Vent Manufacturer: Studor, Inc. Connec on Size: 1 1/4 or 1 1/2 Model #: Trap Vent Item #: or The compact Studor Trap-Vent is a combined trap with a 2 water seal, and an integral AAV, reducing the need for secondary ventilating and replacing conventional P-traps. The valve within the Trap-Vent opens and admits fresh air when the negative pressure occurs from a fixture discharging into the system. This equalizes the pressure within the system and protects the trap seal. When the flow stops, the valve closes by gravity, preventing any transmission of sewer gas. The Trap-Vent can support a twenty foot head pressure. A. The Trap-Vent is for use on a lavatory, water cooler or sinks that do not receive a discharge from any appliance. Trap-Vent is rated up to 6 DFUs on a horizontal wet vent. B. Note, Trap-Vent cannot be installed on kitchen sinks, laundry tubs or a sink that receives a discharge from any kind of appliance. A. The Trap-Vent should be connected to the piping in accordance with the manufacturer s installation instructions. B. The Trap-Vent should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for ever building drainage system. D. The Trap-Vent should not be installed as a vent terminal for any special (chemical) waste system or in supply and return air plenums. E. For installation in areas with temperature range between +32 F and +150 F. Accessories: A. White Cladding is available for a designer finish. The cladding simply snaps over the Trap-Vent Body. A. Body: UV Stabilized ABS (acrylonitrile butadiene styrene) B. Membrane: Synthetic Rubber Trap-Vent is for use on a lavatory, water cooler or on sinks that do not receive a discharge from any appliance. Trap-Vent is rated up to 6 DFU on a horizontal wet vent. Trap--Vent cannot be installed on kitchen sinks, laundry tubs, or a sink that receives discharge from any kind of appliance. Trap-Vent must be installed in a vertical position in an accessible location which permits free movement of air into the valve. Do not use where pumps or pressurized flushing devices are used. Do not install Trap-Vent where it could be subject to subfreezing temperatures or temperatures exceeding 150 F. Please follow all instructions carefully during installation. This devise is not a substitute for ALL conventional venting situations. Listings are subject to change without notice. Codes compliance will vary per State and Municipality, please verify with your local code officials before installing. Tailpieces and adapters were not tested or listed by NSF International for this production location. Product can also come with white cladding model, Distribu on Parkway, Collierville, TN Fax:

7 Trap-Vent Manufacturer: Studor, Inc. Connec on Size: 1 1/4 or 1 1/2 Model #: Trap Vent Item #: or B A C Cladding E D M L F I N H J K G O P Q R 1 1/4 outlet pipe U T S 1 1/2 outlet pipe 500 Distribu on Parkway, Collierville, TN Fax: Dimension Inches A 1 1/4 B 5/8 C 2 D 4 1/16 E 2 7/8 F 1 7/16 G 5 1/16 H 1 3/4 I 1 1/16 J 21/8 1 1/4 1 1/2 L 3 3/16 M N O 5 3/16 P 11/2 Q Ø1.25 R 8 S Ø1.5 T Ø1.625 U 8 K (outlet option)

8 Air Admittance Valve Recess Box D C H A B E F G I SPECIFICATION Studor offers a recess box and grille ideally suited for in-wall installation of its Mini-vent, Redi-Vent, and Tec-Vent Air Admittance Valves. The recess box includes an integral 1 1/2 threaded connection with integral test cap for easy installation as well as esthetically pleasing solution while providing code required accessibility to the valve. Recess box shall be connected to 1 1/2 or 2 PVC or ABS DWV piping. The recess box shall be listed to IAPMO or ICC-ES standards and include a one-piece snap-on grille as manufactured by IPS Corporation. DIMENSIONS Recess Box Snap On Grille A Width (w/flanges) 5 7/8" G Width 8" B Rough In Width 4 1/8" H Height 6 5/8" C Overall Height 7 1/8" I Flange Depth 7/8" D Rough In Height 5 1/2" E Depth 3 5/8" F Depth (from Flanges) 3 1/32" Product # Description Mini Recess Box Mini Recess Box with Redi Vent AAV 500 Distribu on Parkway, Collierville, TN TEL: Fax:

9 P.A.P.A. Positive Air Pressure Attenuator Manufacturer: Studor, Inc. Connec on Size: 3 spigot Model #: P.A.P.A. Item #: The P.A.P.A. device is the perfect compliment to Studor Air Admittance Valves (AAVs). Together they form the Studor Single Pipe System (SSPS), a total solution to building venting requirements. The Studor AAVs deal with the negative pressure in the system while the P.A.P.A. effectively deals with the positive pressure transients. The combination of the two maintains the perfect system balance quickly and efficiently throughout the system preventing siphonage and blowing of traps. For commercial use in multi-story buildings The P.A.P.A. can be used in conjunction with a conventional DWV system or in a system with AAVs. The P.A.P.A. device shall be connected to the piping in accordance with the manufacturer s installation instructions. 29 ½ 7 ⅞ A. One gallon capacity B. Expandable capacity up to four gallons; series assembly provides additional capacity C. Operating temperatures 40 to 150 F. D. Rated for 5 PSI E. Limited lifetime warranty for replacement of defective devices. A. PVC housing B. Butylene bag 3 spigot Performance Standard: ASSE Performance Requirements for Positive Pressure Reduction Devices for Sanitary Drainage Systems. International Plumbing Code (IPC) - Section Alternate Materials, Methods and Equipment Uniform Plumbing Code (UPC) Section Alternative Materials and Series Assembly Maximum number of units: 4 Air Capacity US Gallons 1 unit 1 2 units 2 3 units 3 4 units 4

10 TEC-VENT Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 1 1/2 Model #: TEC VENT Item #: An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent, and island fixture vent that is provided to prevent siphonage of a fixture trap. An air admittance valve can be used as an alternative to extending a vent through the roof (or sidewall) to the open atmosphere. A. The TEC-VENT shall be located a minimum of 4 above the horizontal branch drain or fixture drain being vented and a minimum of 6 above the flood level of the highest fixture for stack venting. B. Each valve should be installed in an accessible location. A. The valve should be connected to the piping in accordance with the manufacturer s installation instructions. B. The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed as a vent terminal for any special (chemical) waste system. E. The valve may be installed on sewer ejectors or in supply and return air plenums, if installed according to engineer design and prior local code approval. F. For installation in areas with temperature range between 40 and 150 F. G. Not for installation in non-neutralized special (chemical) waste systems. A. Screening on the inside and outside of the valve to protect the sealing membrane from insects and debris. B. Ability to divert condensation away from sealing membrane. C. UV rated. D. Limited lifetime warranty for replacement of defective valves. Flame-retardant polycarbonate resin valve with silicone membrane. ANSI/ASSE 1051 Single fixture and branch type AAVs ANSI/ASSE 1050 Stack type AAVs NSF Standard 14 Plastics Piping System and Components UL Standard 2043 Interna onal Plumbing Code (IPC) Interna onal Residen al Code (IRC) Uniform Plumbing Code (UPC Sec on Alterna ve Materials and Methods Na onal Standard Plumbing Code (NSPC) Appendix E Na onal Plumbing Code of Canada (NPC) List- ings: AIR ADMITTANCE VALVES DISCRETE PRODUCTS INSTALLED IN AIR HANDLING SPACE (PLENUMS) As to Heat Release and Smoke Op cal Density Only 9DA2 Horizontal Branch Size 1 1/ Stack Size 1 1/

11 CHEM-VENT Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 1 ½ Model #: CHEM VENT Item #: The CHEM-VENT air admittance valve shall be acceptable as a vent terminal for a nonneutralized special waste system to prevent siphonage of the fixture trap. A. The CHEM-VENT should be located a minimum of 4 above the horizontal branch drain or fixture drain being vented. B. Each valve should be installed in an accessible location. A. The valve should be connected to the piping in accordance with the manufacturer s installation instructions. B. The valve should be installed in the vertical, upright position after rough-in and pressure testing of the DWV system. C. A minimum of one vent shall extend to the open atmosphere for every building drainage system. D. The valve should not be installed in supply and return air plenums. E. For installation in areas with temperature range between 40 F and 212 F. F. The valve can be installed in non-neutralized chemical waste systems provided the system is designed by a design professional. A. Ball valve sealing assembly B. Will vent up to 6 DFUs C. Designed for chemical waste systems D. Screening on the inside and outside of the valve to protect the sealing assembly from insects and debris E. Limited lifetime warranty for replacement of defective valves. A. Flame Retardant Polypropylene (conforming to D-4101) B. O-ring is made from Ethylene Propylene Diene Monomer (EPDM) ASSE 1049 Performance Requirements for Individual and Branch Type Air Admittance Valves for Chemical Waste Systems 6 3/16 CHEM VENT 2 3/16 1½ Sch. 40 International Plumbing Code (IPC) Uniform Plumbing Code (UPC Section Alternative Materials and Methods National Standard Plumbing Code (NSPC) Appendix E Listings: Horizontal Branch Size 1 1/

12 MAXI-FILTRA Air Admittance Valve Manufacturer: Studor, Inc. Connec on Size: 3 or 4 Model #: MAXI-FILTRA Item #: Item #: 20700, Replacement Cartridge The MAXI-FILTRA is a two way vent, which filters air in both directions. It is designed for outdoor use only on septic tanks and lift stations. It is UV rated and comes with a replaceable carbon filter to eliminate bad odors. MAXI-FILTRA 4⅞ Buildings connected to the main sewer can also benefit from the use of the MAXI- FILTRA, but Studor technical department must be contacted so that installation feasibility can be determined. The MAXI-FILTRA, as part of the complete STUDOR System eliminates sewer gases from entering buildings or polluting the surrounding areas. It can also be retro-fitted in an existing plumbing system provided that all design and installation criteria are met. 5-1/4 A. The MAXI-FILTRA is for outdoor use only A. Install filter after drainage and waste system has been roughed in and tested. B. Install valves in accessible locations to allow for filter cartridge replacement. C. Connect valves to piping in accordance with manufacturer s instructions. D. Do not install valves on chemical waste systems or in supply and return air plenums. E. The MAXI-FILTRA can be installed vertically or horizontally F. The MAXI-FILTRA contains a replaceable carbon filter cartridge which can last up to 2 years. 3 A. UV inhibitor in resin compounds for exposure to sunlight B. Active Charcoal Filter replaceable cartridge A. ABS (acrylonitrile butadiene styrene) B. Active Charcoal Filter replaceable cartridge C. Rubber connector 4 Push-Fit Connector 500 Distribu on Parkway Collierville, TN FAX:

Effective Date: October 2016 Void After: October Product: Air Admittance Valves File No. C-3803

Effective Date: October 2016 Void After: October Product: Air Admittance Valves File No. C-3803 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT DATE OF AUTHORIZATION June 28, 2001 BMEC REFERENCE BMEC # 01-07-259 BMEC APPLICATION # BMEC #A 2001-10 OATEY CANADA INC. SURE-VENT AND

More information

STACKS AND STACK VENTS

STACKS AND STACK VENTS CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES

More information

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC People Helping People Build a Safer World Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC Installation, Flexibility and Opportunity for Savings Lee Clifton, Senior Director of PMG Resources,

More information

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof. CHAPTER 9 VENTS SECTION 90 GENERAL run undiminished in size and as directly as possible from the building drain through to the open air above the roof. 90. Scope. The provisions of this chapter shall govern

More information

CHAPTER 9 VENTS SECTION

CHAPTER 9 VENTS SECTION CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code ProVent Systems Plumbing Fundamentals Educational Literature Comparison of ProVent Design Rules and The International Plumbing Code Guide to Contents Topics and Descriptions Page Interior views of the

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

Tube Clamp Submittal Information Revision A: July 25, 2013

Tube Clamp Submittal Information Revision A: July 25, 2013 Tube Clamp Revision A: July 25, 2013 Polypropylene (PP) Tube Clamps secure ½" and ¾" Uponor crosslinked polyethylene (PEX-a) tubing products. Suspension Standard Description Part Number A B C Weight Tube

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes 02 AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Introduction For any system which drains waste water from a property to function correctly,

More information

plumbing for greywater

plumbing for greywater plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of

More information

APPENDIX L ALTERNATE PLUMBING SYSTEMS

APPENDIX L ALTERNATE PLUMBING SYSTEMS ALTERNATE PLUMBING SYSTEMS L 1.0 General. L 1.1 Applicability. The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

Manufactured specifically for Acid Waste systems. NSF certified to meet all performance standard of ASSE 1051

Manufactured specifically for Acid Waste systems. NSF certified to meet all performance standard of ASSE 1051 CHEM-VENT VENT The CHEM-VENT VENT Manufactured specifically for Acid Waste systems Material is NSF 014 and ASTM D-4101 compliant NSF certified to meet all performance standard of ASSE 1051 Designed and

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

CHAPTER VI BUILDING PLUMBING

CHAPTER VI BUILDING PLUMBING CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

Is Sewer Gas Giving Your Customers the Wrong Impression?

Is Sewer Gas Giving Your Customers the Wrong Impression? Is Sewer Gas Giving Your Customers the Wrong Impression? Prepared by Dialectic INTRODUCTION We ve all been there. You walk into a public restroom and you immediately wonder if one of the toilets is overflowing.

More information

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR ELECTRICAL OR HIGH-DENSITY MAGNETIC ANTI-SCALE OR WATER CONDITIONING APPLIANCE IGC 91-2009 1. PURPOSE 1.1 The purpose

More information

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

WATER HAMMER ARRESTORS & MISC. SPECIALTIES TABLE OF CONTENTS Pictorial Index Water Hammer Arrestors Certification Sizing & Placement Backwater Valves Typical Installations Trap Seal Primers Compliance Pressure & Flow Characteristics Typical Installations

More information

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

Denotes a new question! Denotes a revised/revisited question. September 2009 General: General: 1) (Q) What does a contractor/permit holder have to supply for an inspection? (A) Section 107.2 of the NC Administrative Code states that it is the duty of the permit holder to provide access

More information

$0.98 $ KITCHEN SINK STRAINER, 3-1/2" x BATH TUB DRAIN, 1-15/16" x 2-3/4" x $ $1.89

$0.98 $ KITCHEN SINK STRAINER, 3-1/2 x BATH TUB DRAIN, 1-15/16 x 2-3/4 x $ $1.89 *s are Subject to Change without Notice.* WASHERS Rubber Beveled 5-1915 CLOSET, 3/8" O.D. TUBE $0.20 5-1916 CLOSET, 1/2" O.D. TUBE $0.20 5-1917 LAVATORY, 1/2" TALL x 3/8" O.D. $0.20 TUBE 5-1849 LAVATORY,

More information

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS EXTRA HEAVY OR SERVICE

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS EXTRA HEAVY OR SERVICE ICC-ES Report PMG-1083 Reissued 05/2017 This report is subject to renewal 05/2018 EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS EXTRA HEAVY OR SERVICE DIVISION: 22 00 00 PLUMBING SECTION: 22 13

More information

Code 3Check Plumbing. Third Edition. INTRODUCTION u CODES u ABBREVIATIONS. Abbreviations. By michael casey, douglas hansen & Redwood Kardon

Code 3Check Plumbing. Third Edition. INTRODUCTION u CODES u ABBREVIATIONS. Abbreviations. By michael casey, douglas hansen & Redwood Kardon INTRODUCTION u CODES u ABBREVIATIONS Code 3Check Plumbing Third Edition By michael casey, douglas hansen & Redwood Kardon Illustrations and layout by Paddy Morrissey 2006 by The Taunton Press, Inc. ISBN

More information

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

The most advanced Supply Box System from Oatey - the choice of plumbing professionals. T MT M INFINITE SOLUTIONS The most advanced Supply Box System from Oatey - the choice of plumbing professionals. UNIVERSAL SINGLE BOX PLATFORM SNAP-LOCK DESIGN INSTALLATION VERSATILITY Oatey 2017 Oatey

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

PRODUCT DATA SHEET (ver.04/ )

PRODUCT DATA SHEET (ver.04/ ) PRODUCT DATA SHEET (ver.04/02.2018) 1. Name Ventilation and air admittance valves for sewage UniVent venting device Exhaust systems Rubber flanges 2. Pro overview Sewer venting cowls and exhaust systems

More information

How To Size A Big Dipper Unit

How To Size A Big Dipper Unit Sizing Big Dipper Systems In Food Service Operations How To Size A Big Dipper Unit The purpose of this sizing procedure is to give a specifying engineer a simple method for determining the proper size

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

DRAIN LINE ADAPTERS. Innovative Code Listed Products for the Water Treatment & Plumbing Industry. Eco-Tech TMDLA Series

DRAIN LINE ADAPTERS. Innovative Code Listed Products for the Water Treatment & Plumbing Industry. Eco-Tech TMDLA Series A CONSCIOUS COPOATION TM Innovative Code Listed Products for the Treatment & Plumbing Industry Eco-Tech TMDLA Series DAIN LINE ADAPTES DEALE CATALOG & PICE LIST Effective March 2011 Model DLA 9 TM Model

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions 1. What is back-siphonage? Back-siphonage is the reversal of normal flow in a system caused by a negative pressure (vacuum or partial vacuum) in the supply piping. 2. What factors

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia Pro Vent TM Guide to Design and Usage Provent Single System Handling Installation Corrosion Ease Simplicity Resistance IPMO Copyright (c) 2014, Pro Vent Systems Inc., plus *2016 Revisions ll Rights Reserved

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Installation guide and material checklists

Installation guide and material checklists Featuring Flexibility Installation guide and material checklists Series 3 This guide must only be used by a quali!ed heating installer/service technician. Read all instructions, including the boiler manual

More information

Habitability Guidelines

Habitability Guidelines Habitability Guidelines for Relocated Manufactured Homes dced.pa.gov/mh @PADCEDnews Purpose The purpose of these habitability guidelines is to provide a reasonable level of assurance that the relocated

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. The minimum air gap for a fixture with an effective open of 1/2", located away from a

More information

Effective Date: December 2017 Void After: December Product: Outlet Boxes (Washing Machine) File No. 2150

Effective Date: December 2017 Void After: December Product: Outlet Boxes (Washing Machine) File No. 2150 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

PLUMBING INSTALLATIONS

PLUMBING INSTALLATIONS PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS The Design Guidelines, which follow, are intended to supplement the Educational Specifications and State Requirements for Educational Facilities (SREF). Note: All fittings shall be installed by no less

More information

SUPPLEMENTARY INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

consider rainwater harvesting and reuse DESIGN APPROACHES

consider rainwater harvesting and reuse DESIGN APPROACHES consider rainwater harvesting and reuse DESIGN APPROACHES rainwater AS A SUSTAINABLE RESOURCE D RAINWATER HARVESTING The on-site collection, treatment and storage of rainwater typically using rooftop catchment

More information

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

The most advanced Supply Box System from Oatey - the choice of plumbing professionals. TM INFINITE SOLUTIONS The most advanced Supply Box System from Oatey - the choice of plumbing professionals. UNIVERSAL SINGLE BOX PLATFORM SNAP-LOCK DESIGN INSTALLATION VERSATILITY Oatey 2017 Oatey is

More information

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2 CHAPTER 10 TRAPS AND INTERCEPTORS < 1001.0 Traps Required. Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.1, shall be separately trapped by an approved type

More information

GROWMAX WATER Perfect Water for Plants and Gardens

GROWMAX WATER Perfect Water for Plants and Gardens GROWMAX WATER Perfect Water for Plants and Gardens WATER SYSTEMS FOR HYDROPONICS AND GARDENING GROWMAX 3000 Ultra-Pure Reverse Osmosis Water System Up to 3000 L/D of Pure Water Don't forget to register

More information

Fleck 5600 Carbon Filter Installation & Start Up Guide

Fleck 5600 Carbon Filter Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com Fleck 5600 Carbon Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures 4. SANITARY PLUMBING FULLY VENTED SYSTEM On completion of this module, the student should be able to: Design, install and develop bills of quantities for a fully vented modified system for commercial and

More information

INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve

INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve 3/4" Valve with Dual Exits Part # R30.022 Body Construction Cover Plate Black Plastic Housing Part # 88.30.092 Cover Screw Screw Seal O-Ring Part # 88.30.089

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS WATER HEATER STORAGE GAS Lead Paint Risk Factor NONE TABLE OF CONTENTS PART 1: INSTALLATION REQUIREMENTS FOR CONVENTIONAL HOMES... 1 WATER HEATER REPAIR... 1 1. APPLIANCE REPAIR... 1 WATER HEATER INSTALLATION...

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

The BEST Plumbing Specialties. One Source. F 1 BRAIDED SUPPLIES

The BEST Plumbing Specialties. One Source. F 1 BRAIDED SUPPLIES The BEST Plumbing Specialties. One Source. F 1 BRAIDED SUPPLIES F BRAIDED SUPPLY - TOILET - Stainless steel #304 braided supply - PVC inner hose (CSA approved) - Plated brass nuts - 100% pressure tested

More information

RESIDENTIAL PLUMBING OVERVIEW

RESIDENTIAL PLUMBING OVERVIEW ~ 1 ~ ~ 2 ~ RESIDENTIAL PLUMBING OVERVIEW The purpose of this publication is to provide accurate and useful information for home inspectors in order to perform an inspection of the plumbing system at a

More information

LIBBE BASIC INSTRUCTIONS & MEASUREMENTS. 8 (2.44 meter) (73.66 cm) 5 2 (1.6 meter) Approximately 6 (1.83 meter)

LIBBE BASIC INSTRUCTIONS & MEASUREMENTS. 8 (2.44 meter) (73.66 cm) 5 2 (1.6 meter) Approximately 6 (1.83 meter) LIBBE BASIC INSTRUCTIONS & MEASUREMENTS In Corner of Room: Rough Plumbing Connections (Hot & Cold Sewer line, Independent Vent Line and Electrical Outlet) 8 (2.44 meter) 8 (2.44 meter) 29 (73.66 cm) Approximately

More information

Engineering Specifications

Engineering Specifications BRONZE BALL VALVES Model 2970 and Model 2970.10 PART 1: GENERAL 1.1 SUMMARY A. General duty press end type bronze ball valve 1.2 DEFINITIONS A. The following are standard abbreviations for valves: 1. WOG:

More information

RESIDENTIAL PLUMBING OVERVIEW

RESIDENTIAL PLUMBING OVERVIEW ~ 1 ~ RESIDENTIAL PLUMBING OVERVIEW The purpose of this publication is to provide accurate and useful information for home inspectors in order to perform an inspection of the plumbing system at a residential

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)* CHaPTeR 10 TRaPS and INTeRCePTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

B. Section Identification for Fire Suppression Piping and Equipment.

B. Section Identification for Fire Suppression Piping and Equipment. SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

INFINITI K APPLICATIONS MANUAL. Indoor Residential and Tankless Water Heaters. Warning: Follow each appliance's instructions precisely.

INFINITI K APPLICATIONS MANUAL. Indoor Residential and Tankless Water Heaters. Warning: Follow each appliance's instructions precisely. Warning: Follow each appliance's instructions precisely. Installation and service must be performed by a trained and certified installer, service agency or the gas supplier. Application drawings in this

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL INSTALLATION AND SERVICE MANUAL HORIZONTAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000

More information

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 Putnam County Planning & Development Services Building & Zoning Division Compliance Section PO Box 1486 Palatka, FL 32178 1486 Office

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

CWS Plus Sediment Filter Installation & Start Up Guide

CWS Plus Sediment Filter Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com CWS Plus Sediment Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

PRODUCTS THAT CONSERVE, REPAIR AND SAVE!

PRODUCTS THAT CONSERVE, REPAIR AND SAVE! please specify sale sale code code when when ordering PBW92 PBW93 valid valid thru thru 5//5 3// - 5/30/5-3/3/ TAP INTO SAVINGS! PRODUCTS THAT CONSERVE, REPAIR AND SAVE! DON'T FORGET... EPA s Fix a Leak

More information

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY

More information

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL CodeNotes is provided courtesy of the ICC PMG Official Membership Council OFFICIAL CodeNotes Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction Solar

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

WARRANTY POLICY & RECOMMENDED MAINTENANCE

WARRANTY POLICY & RECOMMENDED MAINTENANCE WARRANTY POLICY & RECOMMENDED MAINTENANCE WARRANTY POLICY The following information will explain the plumbing components and warranty coverage for the plumbing systems and fixtures in your new home. It

More information

GENERAL PLUMBING NOTES

GENERAL PLUMBING NOTES GENERAL SYMBOLS GENERAL PLUMBING NOTES PLUMBING LEGEND ABBREVIATIONS N PLAN OR DETAIL NO SHEET NUMBER KEYED NOTE TO PLAN REVISION NUMBER NORTH ARROW. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS

More information

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,

More information

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 To prevent accidents, which could cause serious injury or death, as well as machine damage read these instructions before installation

More information

A GUIDE TO PASSING THE PLUMBING EXAM

A GUIDE TO PASSING THE PLUMBING EXAM A GUIDE TO PASSING THE PLUMBING EXAM BASED ON THE INTERNATIONAL PLUMBING AND FUEL GAS CODES WRITTEN BY JOHN WHITE REVISED 2014 2007-2014 This manual is the sole property of Energy Marketing Services. No

More information

2009 IRC. and Fuel gas Provisions

2009 IRC. and Fuel gas Provisions 2009 IRC Q &A Plumbing, MechanICAl and Fuel gas Provisions TABLE OF CONTENTS PREFACE... vii ABOUT THE INTERNATIONAL CODE COUNCIL...viii PLUMBING PROVISIONS... 1 CHAPTER 25 PLUMBING ADMINISTRATION....3

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions? Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Dishwasher Installation Manual

Dishwasher Installation Manual Dishwasher Installation Manual DW 51600 SS DW 51600 FBI DWT 51600 SS DWT 51600 FBI DWT 81800 FBI DWT 81800 SS DWT 81800 SSIH DWT 81800 SSWS DWT 52600 WIH DWT 52600 SSIH DWT 52600 BIH DWT 52800 WIH DWT

More information

2009 IPC ,IMC Q &A ANDIFGC

2009 IPC ,IMC Q &A ANDIFGC 2009 IPC,IMC ANDIFGC Q &A TABLE OF CONTENTS PREFACE.... ix ABOUT THE INTERNATIONAL CODE COUNCIL...x IPC CHAPTER 1 SCOPE AND ADMINISTRATION...1 Section 101 General... 1 Section 102 Applicability... 1 Section

More information

Dishwasher Installation Instructions DW 24XT/DW 24XV

Dishwasher Installation Instructions DW 24XT/DW 24XV Dishwasher Installation Instructions DW 24XT/DW 24XV Installation Instructions Dishwasher BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Observe all governing codes and ordinances.

More information

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse TANKLESS HIGH EFFICIENCY CONDENSING WATER HEATERS COMMERCIAL-GRADE RESIDENTIAL / COMMERCIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to.95 Uniform Energy Factor

More information

Duraplus ABS for Secondary Loop Refrigeration Control Systems

Duraplus ABS for Secondary Loop Refrigeration Control Systems Duraplus ABS for Secondary Loop Refrigeration Control Systems SECONDARY LOOP REFRIGERATION CONTROL SYSTEMS High Pressure Pipe, Valve & Fittings Environmentally Friendly Cooling Systems Low Temperature

More information

Installation / Assembly

Installation / Assembly Cabinet Cut-out Dimensions...4 Gas Requirements and Connection...5 Leak Testing Procedure....6 LP Gas...7 Natural Gas...9 Installing Side Burner with a Grill...10 Save these instructions! Copyright 2009-2010

More information