1 using mini-splits AS A primary heating source Locating effective evaporator and condenser locations is critical to ductless heating success. BY JAMES BOWMAN Unless specified, images courtesy of RectorSeal Corp. L ocation, location, location are the three key words for real estate and ductless mini-split heating installations. Location is important in mini-split air-conditioner installation, but it is even more critical when the unit is also a primary heating source. For example, wall-mounting an evaporator coil over a bookshelf, kitchen cabinetry, curio cabinet or other tall-standing home furnishing will inevitably lead to poor circulation and short-cycling in the mini-split s heating mode. Many minisplit installers may not realize that the louvers on most evaporator brands default to outward or downward air-flow direction when in cooling or heating mode, respectively. In cooling mode, the louvers direct the air out across the ceiling so it will descend toward the floor and displace warmer air toward the ceiling. Therefore, a 6-ft-high curio cabinet positioned under a wall-mounted evaporator does not affect the air flow in cooling mode. However, in the heating mode, the louvers automatically direct air flow down toward the floor so that the heated air then rises and more evenly tempers the air from floor to ceiling. Thus, an air-flow blocking curio cabinet deflects the air toward the unoccupied ceiling zone and then short-cycles, because the thermostat senses setpoint temperature. The result is an undesirable occupied zone temperature. The condenser location and positioning for ductless heating 22 RSES Journal DECEMBER 2015 In the heating mode, a ductless heating evaporator automatically adjusts louvers down toward the floor so that the heated air then rises and more evenly tempers the air from floor to ceiling. Wall-mounting these units over anything that can deflect the air toward the unoccupied ceiling zone can short-cycle the unit because the thermostat senses setpoint temperature. is also critical in terms of weather, environment and human interaction. The outdoor condenser must be raised 4 in. above the grade, as per most manufacturers recommendations and some jurisdictions code requirements. Northern installations must consider a condenser mounting above the snow line that is determined by local code requirements and seasonal snow accumulation expectations. To endure extreme sub-zero cold weather, the condenser should be positioned so that the house blocks typical winter highwind direction. Condenser baffles, which are available from some mini-split brands, can also be used to throttle wind infiltration into the condenser and allow the unit to perform with better heat transfer. Likewise, a house built in a flood zone and susceptible to springtime ice melts will need its ductless heating mini-split condenser mounted to an appropriate height. There are several condenser-mounting strategies that go beyond concrete pads. HVAC accessory manufacturers have

2 The condenser location and positioning for ductless heating is also critical in terms of weather. Northern installations must consider a condenser mount above the snow line, depending upon local code requirements that are based on snow accumulation forecasts. Image courtesy and copyright of South Mountain Co., West Tisbury, MA. Besides snow and flooding, drainage is another reason manufacturers require condensers raised a minimum 4 in. above the slab, roof line or grade. developed load-bearing metal brackets designed especially for most mini-split condensers challenges. Some of these include: ga wall mount for any height; ga pad mount to raise the condenser up to 4 in.; gan adjustable mount to level the unit on sloped roofs; ga slab support to install above grade; and ga soffit mount for hanging. Besides snow and flooding, drainage is another reason manufacturers require condensers raised a minimum 4 in. above the slab, roof line or grade. In heating mode, the evaporator and condenser swap roles in winter operation via a valve that reverses refrigerant flow. When the reversing valve is activated, heat is rejected indoors and condensate occurs outside and drains through the condenser s cabinet bottom. If not raised, the condenser s condensate can become blocked or frozen and will not drain properly away from the unit. Accessory manufacturers have designed footing mounts, sometimes made of recycled tire rubber, with channels that accommodate two legs of a mini-split condenser. Equipment mounts and footings are made to be more aesthetically pleasing than concrete blocks and they do not require extra labor that cutting and weather-treating wood does for outdoor use. These same footings are also invaluable for getting condensers up and away from flat-roof drainage patterns without damaging sensitive roof materials, such as the white reflective membrane. They also attenuate sound and vibration transmission into the home. Outdoor positioning should also be considered for direct salt spray from ocean properties. Using the home to block anticipated high winds and salt spray can extend the life cycle of the condenser. Additionally, high crime or sports and landscape areas need condensers positioned out-of-reach of thieves, errant balls and weed whackers and projectiles from lawnmowers. DECEMBER 2015 RSES Journal 23

3 Accessory manufacturers have designed footings, sometimes made of recycled tire rubber, with channels that accommodate the two legs of a mini-split condenser. In addition to their aesthetics, they work well for equipment footings on flat roofs and help get the condenser above the roofline without the use and extra weight of a concrete pad. They also attenuate sound and vibration transmission into the facility. New codes affect ductless heating Today s HVAC accessory manufacturers make mounting easy with wall brackets that can elevate ductless heating condensers out of reach of weed whackers, projectiles from lawnmowers and other dangers from landscaping and lawn care. Image courtesy and copyright of South Mountain Co., West Tisbury, MA. 24 RSES Journal DECEMBER 2015 The 2015 International Residential Code (IRC) (Section ) now mandates a trap or a check valve be installed in-line with all gravity drain lines in ductless mini-splits. A 3-in.-long, in-line check valve designed for push-fitting into 5/8-in. drain hoses might be a better choice than a trap. Many traps are originally designed for conventional unitary equipment and will cause a drain restriction on mini-splits. Many manufacturers also call for a trap or check valve to be a minimum of 12 in. away from and below the drain pan so that enough water weight can open the one-way door. The 2015 IRC is not expected to be adapted by most jurisdictions until 2016 or 2017, however some states, such as Delaware, have already incorporated it. Florida is close to incorporating it (or will have incorporated it by the time this feature is printed). In the heating mode, drain-line check valves are critical for preventing: cold-air infiltration for energy efficiency, allergen infiltration for indoor air quality, evaporator coil cleanliness for lower maintenance costs, and insect infiltration protection, according to code review committee explanations. Today s tightly sealed homes have helped attract more air infiltration through the condensate drain hose. Mini-split installers should not use vinyl tubing when gravity draining, because it is prone to kinking and mold growth. A better alternative is a corrugated, kink-resistant polyethylene

4 A plastic wall sleeve will help seal an outdoor wall penetration and prevent cold-air infiltration during ductless mini-split heating. Some wall sleeves are adjustable and can telescope to span most wall widths or a combination of sleeves can be used in tandem to cover wider walls. Today s tightly sealed homes have helped attract more air infiltration through the condensate drain hose. vinyl drain hose designed specifically for mini-split condensate. There is little danger of freezing when running drain hose through an unconditioned space, because there is little condensate production indoors during winter months. However, that same unconditioned space in summer months can produce sweating on drain hoses and surrounding area moisture damage. An insulated drain hose will minimize sweating. Another cold-air infiltration concern is the hole made in the wall to allow lineset and drain-hose access. Therefore a plastic, properly-sealing wall sleeve will help close WHAT YOU DON T SEE IS WHAT YOU GET C155 LIMITED EDITION 5-Year All Inclusive Warranty* EOS Long Life Sensors Complete Combustion Kit U E i C a m o H a t ** QUANTITIES LIMITED C155KIT Camouflage Limited Edition: part # C155LE Camo Combustion Analyzer, Infrared Thermal Printer, Flue Probe, 2 K-Type Temperature Probes, 2 Static Pressure Hoses, True Draft Probe, Gas Pressure Probe, AC Adapter, Hard Carrying Case, Thermal Paper Roll, Particle Filter, Inlet Tube/Probe Connecter, Quick Start Guide, Owners Manual, 5-Year All Inclusive Warranty* and UEi Camo Hat**. *5-Year All Inclusive Warranty requires product registration. **UEi Camo Hat sent from UEi upon receipt of product registration. Quantities limited. Camouflage patterns vary by analyzer. For complete details see participating distributors or contact UEi Test Instruments: Copyright 2015 UEi Test Instruments All rights reserved Circle Reader Service No. 54 DECEMBER 2015 RSES Journal 25

5 The 2015 International Residential Code (IRC) (Section ) now mandates a trap or a check valve be installed in-line with all gravity drain lines in ductless mini-splits. A 3-in.-long, polyethylene vinyl inline check valve designed to be push-fit into 5/8-in. drain hoses might be a better choice than a trap, which may not fit inside a mini-split evaporator. the penetration to any outdoor infi ltrations. Some wall sleeves are more universal in that they are adjustable and can telescope from 4 in. to 7 in. to span most wall widths. Two wall sleeves can be paired together to cover walls wider than 7 in. Cleaning for ductless heating Like the cooling mode, heating requires a clean evaporator coil for optimal wintertime heat transfer. Too many consumers think mini-splits are exclusively for air-conditioning and do not realize homes depending on a mini-split as a primary heating source must be clean to start the winter season. A dirty evaporator during the heating season could overheat and potentially shut off the unit. Condenser mounts like this sloped-roof version, help accommodate job challenges confronting ductless minisplit installers. Startup during a new construction project could also get the coil dirty, as excessive dirt and dust can be drawn through and deposited on the evaporator. Cleaning minisplits, whether it is for summer or winter operation, requires special care, techniques and cleaning agents that are different than conventional unitary equipment coils. Cleaning agents should be safe for the aluminum, copper and metal alloys of sensitive evaporator coil tubing, as well as fins and plastic housing 26 RSES Journal DECEMBER 2015 covers on all mini-split brands. Cleaning agents should also be safe for use with mini-split piston, diaphragm and peristalticstyle mini-split condensate pumps, which are code-mandated accessories on interior wall evaporator coils that are not able to gravity drain condensate outdoors. Outdoor condensers should be outfitted with a tamperproof refrigerant port locking cap that can only be removed with a special tool available at HVAC wholesalers. The emergence of teenage deaths from huffi ng refrigerants from outdoor condensers has prompted the IRC-2015 (M1411.6) to mandate locking caps on any new installation and now any existing unit that is opened for service. Contractors should consider two things when installing mini-splits. Cooling and heating modes are decidedly different and require well-thought locations to accommodate both functions. James Bowman is the National Technical Manager HVACR for RectorSeal Corp. (Houston, TX), which offers mini-split installation accessories. Prior to joining RectorSeal, Bowman was a service tech at several HVACR service contractors. He is EPAcertifi ed, NATE-certifi ed, holds a Class A contractor license in Texas, and has installed and serviced dozens of ductless minisplits representing most brands. For more information, visit or jamesb@rectorseal.com. Ductless (Mini-split) Heating Evolution When ductless mini-splits first emerged in the United States 30 years ago, they were used for cooling only. When heat-pump models later arrived on the scene, except in southern regions, they were not used as the primary heating source. The emergence of the inverter-controlled compressor as well as other technological advancements have been responsible for the surge of ductless heating. Recently, the technology has improved ductless heating capacity and made the relatively new HVAC category suitable as a primary heating source, even in temperatures well below 0 F. The inverters and onboard microprocessors allow for the adjustment of blower and fan rpms, refrigerant flow and even the compressor speed via variable-frequency drives to maintain heating capacity with decreasing outdoor temperatures. While many HVAC contractors concentrate on the cooling side of ductless mini-splits, the heating side must also receive careful attention, especially in locating them in the best possible areas of the home for the highest efficiency and performance.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

EXHIBIT C DUCTLESS HEAT PUMP SPECIFICATIONS

EXHIBIT C DUCTLESS HEAT PUMP SPECIFICATIONS Page 1 of 5 DUCTLESS HEAT PUMP SPECIFICATIONS 1. NEW EQUIPMENT REQUIREMENTS a. Materials Equipment shall be a split system Ductless Heat Pump (DHP) with an inverter-driven, variable speed compressor, a

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems) Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems) Figure 17-2 Commercial refrigeration Unit Figure 17-3 Industrial process chiller Figure 17-4 Basic refrigeration

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

WineZone Ceiling Mount Ductless Split 15

WineZone Ceiling Mount Ductless Split 15 WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

C. Samples for Initial Selection: For units with factory-applied color finishes.

C. Samples for Initial Selection: For units with factory-applied color finishes. SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Air Cooled Condensers 8-2016 Rev 0 Table of Contents General Safety Information 2 Inspection 2 Installation 2 6 Rigging and Assembly 2 Unit Location

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5 Introduction The Scotsman Compact Refrigerator is a unique product, capable of being built into a cabinet because of its front vented, forced-air cooling system. It s also designed to be a companion to

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps 2011 Lennox Industries Inc. Dallas, Texas, USA 506789 01 08/2011 MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps This manual is the property of the homeowner and must be left with the

More information

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

TRANE ALL-ALUMINUM COMFORT COILS PERFORMANCE AND RELIABILITY FROM THE INSIDE. The key to system efficiency TRANE ALL-ALUMINUM COMFORT COILS READ ONLY

TRANE ALL-ALUMINUM COMFORT COILS PERFORMANCE AND RELIABILITY FROM THE INSIDE. The key to system efficiency TRANE ALL-ALUMINUM COMFORT COILS READ ONLY TRANE ALL-ALUMINUM COMFORT COILS PERFORMANCE AND RELIABILITY FROM THE INSIDE The key to system efficiency TRANE ALL-ALUMINUM COMFORT COILS READ ONLY THE TRANE ALL-ALUMINUM COMFORT COILS Assure your system

More information

PAC, NQAC, HQAC, SQAC, EQAC AIR-COOLED CONDENSERS OPERATING AND INSTALLATION INSTRUCTIONS

PAC, NQAC, HQAC, SQAC, EQAC AIR-COOLED CONDENSERS OPERATING AND INSTALLATION INSTRUCTIONS PAC, NQAC, HQAC, SQAC, EQAC AIR-COOLED CONDENSERS OPERATING AND INSTALLATION INSTRUCTIONS SECTION A - CONDENSER LOCATION: The primary considerations for air-cooled condenser location are: i. Essentially

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the operation of reverse-cycle refrigeration (heat pumps) Explain

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

SECTION 7 AIR CONDITIONING (COOLING) UNIT 38 INSTALLATION

SECTION 7 AIR CONDITIONING (COOLING) UNIT 38 INSTALLATION SECTION 7 AIR CONDITIONING (COOLING) UNIT 38 INSTALLATION UNIT OBJECTIVES After studying this unit, the reader should be able to List three crafts involved in air-conditioning installation. Identify types

More information

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6 INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4

More information

Important Facts You Should Know About Your Heat Pump (602) or (520)

Important Facts You Should Know About Your Heat Pump (602) or (520) Important Facts You Should Know About Your Heat Pump (602) 943-3426 or (520) 292-6858 www.chasroberts.com During the cooling season, the heat pump operates like a conventional system. Do Not turn the air

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

EAGLE 2X: C155KIT EAGLE 3X: C157KIT EAGLE 2X: C155 C155 Analyzer Particle Filter Quick Start Guide Owners Manual EAGLE 3X: C157 C157 Analyzer Particle Filter Quick Start Guide Owners Manual EAGLE 2X: C155KIT C155 Analyzer EAGLE 3X: C157KIT

More information

CONDENSATE MANAGEMENT SYSTEMS

CONDENSATE MANAGEMENT SYSTEMS CONDENSATE MANAGEMENT SYSTEMS AG-1100+ Magnetic Float Switch System for Metal Secondary Drain Pans The AG-1100+ is incredibly easy to install. It can be mounted to the drain pan in 10 seconds or less.

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS R-410A - C MODELS COMFORT PACK PACKAGED THRU-THE-WALL AIR CONDITIONER WITH ELECTRIC HEAT INSTALLATION AND MAINTENANCE INSTRUCTIONS National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215)

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System 1.5-5 Ton The DT5BD Series of heat pumps offers exceptional performance. The heat pump, when combined with our

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,1,_2008 Lennox Industries Inc, Dallas, Texas, USA INSTALLATION INSTRUCTIONS CR33 Series Coils EVAPORATOR COILS _ Technical 505,056M LL.L[ Publications 04108 Litho U.S.A. Supersedes 05/05 CR33 Series Coils...

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET General Piping Recommendations and Refrigerant Line Length for Split-System Air Conditioners and Heat Pumps GENERAL GUIDELINES This Split-System (Air Conditioning Condensing/Heat

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EAGLE X: AT A GLANCE................................ LOWEST COST OF OWNERSHIP NO

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16. 14+ SEER R-410a Coil Company, L.P AIR CONDITIONERS UNITED STATES PATENT #D557,394S #D557,395S R-410A Aluminum Coil Series Efficiencies up to 14+ SEER/12 EER Nominal Sizes 1.5-5 Ton Capacities 16.6 to 56

More information

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated,

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

Air Conditioner with Puron Refrigerant MODEL 126B

Air Conditioner with Puron Refrigerant MODEL 126B Air Conditioner with Puron Refrigerant MODEL 126B As an ENERGY STAR Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Preferred

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

AWARNING A CAUTION R-22 OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: 13 SEER - ERCQ SERIES 2 TO 4 TONS LIST OF SECTIONS.

AWARNING A CAUTION R-22 OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: 13 SEER - ERCQ SERIES 2 TO 4 TONS LIST OF SECTIONS. R-22 OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: 13 SEER - ERCQ SERIES 2 TO 4 TONS Certification applies only ISO 9001 when the complete Certified Quality system ls listed Management System with ARI

More information

Lennox 8 Series Single Zone - R-410A

Lennox 8 Series Single Zone - R-410A PRODUCT SPECIFICATIONS MINI-SPLIT SYSTEMS MS8C/MS8H Lennox 8 Series Single Zone - R-410A Bulletin No. 210632 September 2016 Supersedes January 2016 MS8-CI Air Conditioner Indoor Unit MS8-HI Heat Pump Indoor

More information

RDT Refrigeration Book

RDT Refrigeration Book RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.

More information

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement. Aspects of the Compressor Retrofit Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement. B y J o h n P r a l l a n d D e n n y M a r t i n All

More information

Air Conditioner with Puron MODEL 186B

Air Conditioner with Puron MODEL 186B Air Conditioner with Puron MODEL 186B Refrigerant As an ENERGY STAR Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Prior

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM # ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM DETAIL Labor Material FURNACE COMPONENTS 1 Furnish & Install Sight-Impaired Thermostat For Heating and Cooling

More information

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support Contact information Instructors: Don Reynolds 616-560-9903 Doug McGee 517-294-3932 Factory Tech Support 888-593-9988 Product Improvements for 2017 Todays Objectives Job Site Information Sheets Low Ambient

More information

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH #700837 190 PINT MANUAL Rated at 170-pints per day at 86 F/80% RH, 105 pints per day, AHAM - (80 F/60% RH) Rating @ 190Pint 86 F 80%RH 115Pint 80 F 60%RH ONE: IMPORTANT SAFETY INSTRUCTIONS Please read

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

SELF-CONTAINED CRESCENT CUBER

SELF-CONTAINED CRESCENT CUBER Reliability is a beautiful thing TM SELF-CONTAINED CRESCENT CUBER KM-250BAF KM-250BWF INSTRUCTION MANUAL ISSUED: March 14, 2000 REVISED: December 22, 2004 IMPORTANT Only qualified service technicians should

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

Air-Cooling Evaporators

Air-Cooling Evaporators Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare

More information

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80 Installation & Maintenance Data IM 255-6 SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80 Group: Fan coil Part Number: # 106332400 Date: August 2000 Table of Contents Inspection............................................................................

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Central Air Conditioning System

Central Air Conditioning System Owner s Information Manual Central Air Conditioning System NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information,

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12 Installation & Maintenance Data IM 168-5 SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12 Group: Fan coil Part Number: # 107132900 Date: June 1999 Table of Contents Inspection............................................................................

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS 16 SEER / R-410A HIGH-EFFICIENCY 2- TO 5-TON SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY: 24,000 BTU/H TO 57,000 BTU/H The Goodman 16 SEER Air Conditioner uses the environmentally friendly refrigerant

More information

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED 19 SERIES DUCTLESS WALL-MOUNTED HIGH-EFFICIENCY HEAT PUMP AND AIR CONDITIONER UP TO 19 SEER 9.0 HSPF 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE www.daikincomfort.com "I'm a Daikin Comfort

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section. SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.

More information

Withlacoochee Technical College Syllabus Air-Conditioning, Refrigeration and Heating Technology HVAC / R

Withlacoochee Technical College Syllabus Air-Conditioning, Refrigeration and Heating Technology HVAC / R Course Description: Withlacoochee Technical College 2018-2019 Syllabus Air-Conditioning, Refrigeration and Heating Technology HVAC / R This program focuses on the understanding of the heating, air-conditioning,

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

Cold Weather Operation Of Cooling Towers

Cold Weather Operation Of Cooling Towers This article was published in ASHRAE Journal, March 2014. Copyright 2014 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission

More information

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION CONVECTION HEATING AND COOLING UNITS PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 10 SEER Standard Efficiency Split System These units have been designed and tested for capacity and efficiency in accordance with

More information

EVAPORATIVE COOLER PUMPS

EVAPORATIVE COOLER PUMPS EVAPORATIVE COOLER PUMPS ebmpapst Evaporative Cooler Pump EBMALPHA $144.65 @ 1. metre Head @ 2. metre Head Power Supply 32 litres/min 25 litres/min 24V/1/5Hz Nominal Watts 5 watts Outlet Connection 2mm

More information

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE AND WORRY-FREE PERFORMANCE M1200 COMFORT SYSTEMS 14 & 15 SEER LARGE PACKAGED PRODUCTS 15 SEER/81% AFUE/8.0 HSPF ihybrid DUAL FUEL MULTI-STAGE, VARIABLE-SPEED PACKAGED SYSTEMS, 2-5 TONS The ihybrid system

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

More information

"I'm a Daikin Comfort Pro"

I'm a Daikin Comfort Pro www.daikincomfort.com "I'm a Daikin Comfort Pro" Those five simple words can offer you comfort like you ve never experienced. The words mean that the dealer you invited into your home is a highly-qualified

More information

TRANE PACKAGED HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE Exceptional heating and cooling all year long READ ONLY TRANE PACKAGED HEAT PUMPS

TRANE PACKAGED HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE Exceptional heating and cooling all year long READ ONLY TRANE PACKAGED HEAT PUMPS TRANE PACKAGED HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE Exceptional heating and cooling all year long READ ONLY TRANE PACKAGED HEAT PUMPS READ ONLY TRANE PACKAGED HEAT PUMPS Welcome home to the highest

More information

Technical Specifi cations

Technical Specifi cations 1 Technical Specifi cations CONFORMS TO ANSI/UL STD. 1995, ANSI STD. Z21.47 CERTIFIED TO CAN/CSA STD. C22.2 NO. 236, CAN/CSA STD. 2.3 AND CAN/CGA STD. 2.17 PSC - SERIES REV-B Gas Heat / Electric Cooling

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information