EDPAC International Close Control Air Conditioning Products E
|
|
- Jessie Reeves
- 5 years ago
- Views:
Transcription
1 EDPAC International Close Control Air Conditioning Products E
2 The Ranges of Close Control Products comprise of : Close Control Modular Range : Modular units, using R407C/R410A & Chilled Water with capacities from kw. Close Control Twin Circuit Air Cooled Range : A range of Twin Circuit Air Cooled units, using R407C/R410A, from kw in a single frame. Close Control Small Systems Range : Small Systems Range units, using R407C/R410A and Chilled Water, in 2 sizes providing nominal capacities of 6-18 kw. DCS/FCS Chilled Water Units : Chilled Water units in 4 sizes providing nominal capacities of kw. EC Plug Fan Range Units : Chilled Water & DX Air Cooled Units, using R410A, in 7 sizes providing nominal capacities of kw. Packaged Cooling Units : DX Air Cooled packaged units from 3-20 kw using R407C/R410A with optional freecooling.
3 Close Control Modular Range
4 Cooling by DX using Air or Water/Glycol & Chilled Water. Glycol units available with Freecooling & Dual Cooling. Air Cooled units available also as Dual Cool units. Capacities of kw cooling in single and twin circuits kw in 5 kw increments in one Module ( Single Circuit) kw in 10 kw increments in two Modules ( Twin Circuit).
5
6 Twin Circuit Air Cooled Units
7 A range of Twin Circuit Air Cooled units in a single frame. Capacities of kw Cooling. 4 Frame sizes giving 30,40-50,60 & 70,80 kw & 100 kw. All units are Twin Circuit with 2x external air cooled condensers. Dual Cooling version available with addition of chilled water coil.
8
9 Close Control Small Systems Range
10 A range of small DX Air Cooled & Chilled Water units. The Small Systems range comprises 2 unit sizes providing nominal capacities of 6, 12 and 18 kw. Units are available in downflow with top return and upflow with front return. Upflow rear & bottom return also available. There is an option for a dual cooling version of Air Cooled & Chilled Water.
11
12 DCS/FCS Chilled Water Units
13 The Large Systems range of Chilled Water units comprises 4 sizes of nominal capacities of 60, 80, 100 & 120 kw. Units are available in upflow and downflow configurations with top, bottom, front and rear return options. Ideal for very large data center applications where air cooled or water/glycol cooled units would be impractical due to load size.
14
15 EC Plug Fan Range Units
16 The EC Plug fan range of Chilled Water & DX Air Cooled units comprises 7 sizes with nominal capacities from kw Units are available in upflow and downflow configurations with top, bottom, front and rear return options. Chilled water units also have an option to place the fan under the floor increasing capacity EC Plug Fan Range Units
17 EC Plug Fan Range Units
18 Packaged Cooling Units
19 Packaged Cooling Units A range of packaged DX Air Cooled units for Telecom cellular site applications. The ESCU range comprises 3 unit sizes providing nominal capacities of 3-20 kw. R410A & R407C refrigerants EC evaporator plug fans Units are available with an airside economiser for freecooling using outside air.
20 Packaged Cooling Units For Telecom cellular site applications. R410A & R407C refrigerants EC evaporator plug fans
21 Key Components
22 Cabinet Standard 2.0mm Zintec Frame. Interior Metal all Galvanised. 1.2mm Zintec Exterior Panels. Textured Epoxy Powder Paint Finish to RAL Optional Other Paint Colours
23 Cooling Coils Standard 3/8 (10mm) & 1/2 (12mm) OD Copper Aluminium Fins 1.8mm & 2.1mm Fin Spacings Optional Blygold Coating Thermoguard Coating Epoxy Coating Copper Fins
24 Scroll Compressors Sanyo - Japan Scroll Compressors Copeland Belgium Danfoss - France
25 VSD Scroll Compressors Danfoss France/Denmark
26 Forward Curved Fans Nicotra - UK Chaysol - Spain EC Plug Fans Ziehl Abegg - Germany EBM - Germany
27 Humidifier Standard Electrode Steam Boiler Disposable Cylinder Capacity Adjustable % Optional Servicable Cylinder Low Conductivity Cylinder
28 Reheat Standard Electric Type Reheat Stainless Steel Tubular Element Stainless Steel Helicoidal Fins Balanced 2 Stage Airstream overheat stat Optional 3 Stage. Increased Reheat Capacity. 0-10V Thyristor Control. LPHW Reheat on/off or modulating. Hot Gas Reheat.
29 Electric Motors Siemens - Germany Weg - Brazil Motors Standard Foot Mounted IE2 Efficiency Optional EC Fan / Motor IE3 Efficiency IE4 Efficiency (EC Fan)
30 Water Control Valves Honeywell - Germany Johnson Controls - Holland Head Pressure Control Johnson Controls - Holland
31 Water Cooled Condensers Alfa Laval - Sweden GEA - Sweden Standard Brazed Plate Heat Exchanger Stainless Steel Pressed Plates
32 Filters Standard Pleated Media Disposable Type 30-40% Dust Spot G4 to EN 779 Mounted in Return Airstream Optional Up to 70% Dust Spot Panel F5&F6 to EN779 Up to 90% Dust Spot Bag Filters F7&F8 to EN 779 H10 & Carbon Also Available 50mm F7 60% Panel Filter 50mm G3 20% Washable Filter 50mm G4 30% Panel Filter 100mm G4 30% Panel Filter
33 Standard DIN Rail Mounted 4Mb Flash Memory 4x20 Backlit LCD Display Run / Standby Control EC Fan Control Strategies PID Control EXV Valve Control Condenser Head Pressure Control Sensor Calibration User Time Delays Adjustable User Set & Hysteresis Adjustment System Auto Restart Manual Procedure Microprocessor - Controls Carel Italy Johnson Controls - Italy
34 Optional Microprocessor - Controls Carel Italy Johnson Controls - Italy Communication Cards for: MODBUS BACnet MSTP BACnet TCP/IP LON FTT10 SNMP TCP/IP Metasys 128x64 Pixel Graphic Display Touch Screen Graphic Displays Additional Remote Displays Trend Logs in.csv Format
35 Optional Features
36 3 Way Discharge Plenum Dual Cooling Water Warning Condensate Pump F5,F6,F7 Panel Filter F8,F9 Rigid Bag Filter F8 Rigid Carbon Filter Return Air Attenuator Rear / Bottom Return Upsized Motor Smoke / Fire Detector Filter Clog Switch Floorstand Inlet / Outlet Damper Liquid Receiver Oil Separator Fresh Air Connection Compressor Acoustic Jacket
37 Double Skin Panels Twin Belt Drive Volt Free Contacts Other Voltages Hot Gas Bypass Hot Gas Reheat LPHW Reheat Steam Reheat Loss of Water Flow Water Regulating Valves Supply Air Temperature Supply Air Humidity Cleanable Humidifier Low Conductivity Humidifier Comms. Cards
38 PROCESS QUALITY ISO9001/EN29001 Certification since March 1992 All partners certified to ISO9002 /EN29001 PRODUCT CONFORMANCE Product Designed and Manufactured in accordance with ISO9001/EN29001 All Product CE marked through selfcertification DESIGN CONTROL Use of CAD /CAM facilities 2 Solid Edge & 2 Inventor 3D Stations Product Test & Verification
39 IBM Denmark Test Load Bank System under Test Chiller
40 Vistakon J&J Test
41 For more information concerning EDPAC Close Control Products please contact : Mr. Ciaran Coughlan - Director, Sales & Marketing EDPAC International - Cork, Ireland Ph : Fax : ciaran.coughlan@edpac.com Web Site :
> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center
Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)
More informationClose Control Air Cooled Twin Circuit Range
Close Control Air Cooled Twin Circuit Range Engineering Data Manual 50/60Hz ENGINEERING DATA MANUAL 50/60Hz Index Description Page YORK Company Profile 3 This Product Range 3 Other YORK Close Control Product
More informationMission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems
Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint
More informationFlexible & Innovative. Cooling Solutions
Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly
More informationCOOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw
COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding
More information8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications
AlphaCool close control range 8-101kW - 101kW > Typical applications > Data Centres > Telecommunications and ISP facilities > Computer rooms > Clean rooms > Switching stations > Laboratories www.airedale.com
More informationNEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning
: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision
More informationControl Systems. Design & Manufacturing. Eco-Friendly. High Performance
Temperature & Humidity Control Systems Design & Manufacturing DX Air / Water / Glycol Cooled Air and Water Side Economizer Chilled Water Systems Eco-Friendly High Performance OPTIMAL COOLING SOLUTIONS
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationSeries 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.
MISSION CRITICAL Air Conditioning Systems Series 8 Guide Specification 60 Hz S8-GS-602017.doc 2014 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 8 Guide Specification-60
More information2013 Product Range Precision Air Conditioners (CRAC)
2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range RC Group air conditioners range CLOSE CONTROL AIR CONDITIONERS 2,0-244,0kW HEAT PUMP AIR CONDITIONERS 6,3-113,0kW 6,3-101,0kW AIR
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationVertical self-contained air conditioner
Compact and sleek Broad range of functions and performance Energy efficient (EC motor) and self-regulating control Easy to install ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling
More informationNext MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB
6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3
More informationSeries 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.
MISSION CRITICAL Air Conditioning Systems Series 6 Guide Specification 60 Hz S6-GS-602017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 6 Guide Specification-60
More information4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB
4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More informationSeries PS6, Vertical Floor-Mount Units
Series PS6, Vertical Floor-Mount Units Technical Data 60 Hz sps6em6ea.doc Dec-12 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Table of Contents Table of Contents...
More informationnext evo cw next evo cw rcgroupairconditioning
: Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: 6,2 248,0 rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled
More informationNEXT DL NEXT DL. rcgroupairconditioning
NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning
More informationThe system shall be described in the following specification as manufactured by Schneider Electric
Guide Specifications Uniflair LE Twin-Cooled Direct Expansion (DX) Cooling Systems THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTER FORMAT.
More informationModular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified
Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in the late
More informationSystem Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.
High Density Presicion Cooling Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons System 2100 Kompact www.compu-aire.com CA A - 8 34 -K System 2100 K Type Air Cooled - A Chilled Water Cooled - C
More informationDATA & FACTS Close Control Units Multi-DENCO. Flexible and Efficient
DATA & FACTS Close Control Units Flexible and Efficient Type Code Basic Unit Example D M A 0 1 0 D P S I S 4 P E 1 Product Range Cooling System Unit Size Airflow Direction Panel Configuration Heat Exchanger
More informationThe system shall be described in the following specification as manufactured by Schneider Electric
Guide Specifications Uniflair LE Air-Cooled Direct Expansion (DX) Cooling Systems THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTER FORMAT. THIS
More informationUNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded
More informationEcotel Outdoor Upflow Telecom Unit TCU5 - TCU19D 5KW - 19KW
Ecotel Outdoor Upflow Telecom Unit TCU5 - TCU19D 5KW - 19KW T E C H N I C A L M A N U A L Customer Services TCU 5-19kW About Airedale Products & Customer Services WARRANTY All AIAC products or parts (non
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationgforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits
gforce - R-407C Air Cooled, Water/Glycol Cooled 21-106 kw Dual Circuits 1 2 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling
More informationgforce GT R-407C Single Circuit Air Cooled, Water/Glycol Cooled 7-46 kw
gforce GT Single Circuit Air Cooled, Water/Glycol Cooled 7-46 kw 1 2 the pioneer and builder of the most complete line of precision cooling equipment Back in the late 1960 s and early 70 s with the advancement
More informationChilled Water 7 to 211 kw
Chilled Water 7 to 211 kw Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing facility
More informationkw COOLING kw HEATING
Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...
More informationACMVTECH HIGH EFFICIENCY UNITARY AHU
HIGH EFFICIENY UNITARY AHU 50 / 60 Hz R-134A, R407c R-407F, R-410A ACMVTECH HIGH EFFICIENCY UNITARY AHU WATER COOLED CONDENSERS VARIABLE and CONSTANT SPEED VSD FANS ; VSD COMPRESSORS ACMCVTECH UNITARY
More informationMini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data
Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Engineering Manual ABOUT STULZ STULZ is a privately owned, global manufacturer of highly efficient temperature and humidity management
More informationThe system shall be described in the following specification as manufactured by Schneider Electric
Guide Specifications Uniflair LE High Capacity Chilled Water Units THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTER FORMAT. THIS SECTION MUST
More informationAquaflair. Residential and Industrial Cooling Systems
Aquaflair Residential and Industrial Cooling Systems Uniflair Europe SpA Viale della Tecnica, 2 35026 Conselve (Pd) Italy Tel. +39 049 5388211 Fax +39 049 5388212 info@uniflair.com uniflair.com Company
More informationMission Critical Air Conditioning Systems
Mission Critical Air Conditioning Systems wall & ceiling mount Series 7 & 11 1-5 Ton Units Single Circuit Units Designed for Superior Space Utilization Series 7 1.5-2.5 tons Compact wall mounted split
More informationR-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits
R-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system
More informationED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL
DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL COOLING CAPACITY FROM 20,8 TO 93,3 kw ED.X 1462 F U Kc 72 FC The range of direct expansion close
More informationHigh-efficiency room air conditioners
High-efficiency room air conditioners Uniflair TM air conditioners designed for precision environmental control of mission-critical applications schneider-electric.com Schneider Electric policy is one
More informationnext p dw next p dw rcgroupairconditioning
NEXT P: Heat pump air conditioners with upflow air delivery with built-in water/gas exhaustion heat exchanger Cooling Capacity: 7,5 7,0 Heating Capacity: 7, 04,0 A C rcgroupairconditioning R40A PLATE E
More informationModular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified
Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in
More informationyork airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units
york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units YORK YPRE RTR/RTP SERIES Air to air packaged rooftop units Cooling
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationData Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C
Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision
More informationData Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits
Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision
More informationgforce Units Data Aire and Data Temp Series
gforce Units gforce gforce is the most advanced mission critical cooling equipment available on the market today. These units are the most efficient and economical while complying with strict environmental
More informationGLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationTHE ULTIMATE ROOFTOP SOLUTION
Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly
More informationCLIMACIAT AIR COMPACT
Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000
More informationunico pf unico pf rcgroupairconditioning
: ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum
More informationCultivator & Hybrid Cultivator
Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on
More informationAIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW
AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The
More informationLER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS
Indoor motor-driven evaporating units LER 0-0 kw Compact and silent machines with remote dissipation into the air Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split version Electronic expansion
More information50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control
PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationData Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified
Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) with refrigerant Product Description Performance and Electrical Data Dimensional Data Guide
More informationHigh efficiency room air conditioners. Uniflair TM air conditioners Designed for precision environmental control of mission critical applications
High efficiency room air conditioners Uniflair TM air conditioners Designed for precision environmental control of mission critical applications schneider-electric.com Room air conditioners Combining cutting-edge
More informationMAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation
Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow
More informationSTULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual
Indoor Cooling Perimeter STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol Self-contained Precision Air Conditioner Utilizing EC Fan Technology
More informationModular Air-cooled Chillers
Modular Air-cooled Chillers High Seasonal Efficiency (HSE) version Cooling capacity 48-232 kw Trane Flex Series Modular air/water chillers with axial EC fans, inverter driven scroll compressors and microchannel
More informationHigh-efficiency room air conditioners
High-efficiency room air conditioners Uniflair TM air conditioners designed for precision environmental control of mission-critical applications schneider-electric.com 2 High-efficiency room air conditioners
More informationR407C. DB-Aire II Systems 50/60Hz. Precision Environmental Control Unit Cooling Capacity: 2 to 26 TR (7 to 91 kw)
DB-Aire II Systems 50/60Hz Precision Environmental Control Unit Cooling : 2 to 26 TR (7 to 91 kw) DB-Aire II (Outdoor Unit) DB-Aire II (Indoor Unit) R407C Products that perform...by people who care DB-AIRE
More informationData Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified
Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most
More informationunico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning
: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel
More informationKELVIN Clim F497. Kelvin air conditioning
KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,
More informationGLIDER EVO GLIDER EVO. rcgroupairconditioning
: Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid
More informationRTU. Roof Top Units 8 30 Ton. Maxi-Kool.
Maxi-Kool RTU Roof Top Units 8 30 Ton www.compu-aire.com MK A-3 034 -RTU Maxi-Kool Type Air Cooled - A Chilled Water Cooled - C Glycol Cooled - G Water Cooled - W Nominal Tonnage 8 30 Ton Voltage 2-208
More informationEQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM
TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16
More informationSTULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners
Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering
More informationPYXIS U PYXIS U. rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationDATATECH. Precision air conditioners for technological environments 6 220
Precision air conditioners for technological environments 6 220 General Precision air-conditioners that guarantee safe working conditions for data centres, computer rooms and other technological applications
More informationData Aire Series Chilled Water 7 through 50 ton
Data Aire Series Chilled Water 7 through 50 ton ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system
More informationFULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY
C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial
More informationMARSTAIR INDEX. Product Description. Cellarator Units Condensing Units 3-6. Condensing Units - Ducted 7
1 MARSTAIR INDEX Product Description Page(s) Cellarator Units 22-25 Condensing Units 3-6 Condensing Units - Ducted 7 Condensing Units - Greenheat Indoor and Outdoor 8 Cooling s - DX Packaged 9-10 Cooling
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationSKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms
SKY-COM HI-CAP SERIES Precise Environmental Control SKY-COM 15 & 20 TON Series Suited for Telecommunications, Laboratories and Computer Rooms GENERAL MECHANICAL SPECIFICATIONS AIRFLOW CONFIGURATION Units
More informationi-next DX kw FULL INVERTER direct expansion air conditioners for IT Cooling. To be matched with remote air-cooled condenser. rcitcooling.
CLOSE CONTROL AIR CONDITIONERS 3 140 kw FULL INVERTER direct expansion air conditioners for IT Cooling. To be matched with remote air-cooled condenser. The picture of the unit is indicative and may vary
More informationPrecision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C
u n i v e r s a l c o m f o r t Precision air-handling cabinets CIATRONIC System Ultimate precision air-conditioning NA 05.93 C > > CIATRONIC System Precision air- > CIAT, European leader in air-conditioning
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationkw. technicalcatalogue
Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB
More informationkw. technicalcatalogue
Packaged air cooled liquid chillers for outdoor installation equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. 280
More informationEasiCool EZRE. Technical Manual. Downflow and Upflow - Precision Air Conditioning. Direct Expansion. 6kW - 60kW
EasiCool EZRE Downflow and Upflow - Precision Air Conditioning Direct Expansion 6kW - 60kW Technical Manual EasiCool Precision Air Conditioning Introduction Warranty, Commissioning & Maintenance As standard,
More informationGLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning
GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY
More informationGuide Specifications for InRow Direct Expansion
Guide Specifications Guide Specifications for InRow Direct Expansion THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT. THIS SECTION MUST
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationAIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.
AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR Air Conditioner for Telecommunication Base Station Cooling Capacity: 3.4~13.4kW MOBILECOOL-INDOOR unit is one of the products of AIRSYS BTS air
More informationIPAC Air Handling Units
Eaton-Williams IPAC IPAC Air Handling Units Short-form version - extracted from Section 2 of the Installation, Operation and Maintenance Manual Technical Product Guide IPAC (Invicta Precision Air Control)
More informationComputer Room Air-Conditioning 60 Hz. Technical Data
TM Computer Room Air-Conditioning 60 Hz 35 150 kw (10 45 tons) Technical Data Contents Overview.............................................................. 1 Scalable Solution for Critical Environments.................................
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationPackaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB
Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...
More informationAIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.
AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR Air Conditioner for Telecommunication Base Station Cooling Capacity: 3.5kW-13.5kW MOBILECOOL-OUTDOOR unit is one of the products of AIRSYS BTS
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationSTULZ the natural choice. Compact DX Close Control Air Conditioning for High-end Applications
STULZ the natural choice Compact DX Close Control Air Conditioning for High-end Applications Modern Close Control Air Conditioning Highly Efficient, Space-Saving and Cost Effective If you have to remove
More informationMulti-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw
Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic
More informationChilled Water Precision Air Conditioner for Critical Application
AIRSYS-P-SC-OPTIMA-HD-E14507V01.3 HD Chilled Water Precision Air Conditioner for Critical Application Cooling Capacity: 42.1kW~180.9kW OPTIMA product family is designed for medium to large data center.
More information