#300 & #302 CHLORINEIBROMINE FEEDERS

Size: px
Start display at page:

Download "#300 & #302 CHLORINEIBROMINE FEEDERS"

Transcription

1 #300 & #302 CHLORINEIBROMINE FEEDERS R~M%' Features: No special venting required. Completely enclosed-no escaping gases. Positive external no-clog control valve. Feeder is designed to automatically lower the water level so tablets are not soaking during off period of pump. This allows more efficient use of tablets. No equipment damage. Feeds sanitizer directly to pool or spa. All parts replaceable. To prevent over feeding during use, completely close the control valve and the built in check valve will prevent chemical from being fed into pool or spa. It is important to read all information BEFORE proceeding with the installation. The information will guide you in installing your feeder properly and to avoid problems due to improper installation. IFYOUR POOL OR SPA HAS COPPER PLUMBING... STOP!! Never install the feeder into copper plumbing as pipe damage will occur. (See Equipment Safety CAUTION sheet enclosed). NOTE: If heaters are used, a Fireman's Switch or equivalent must be installed to prevent possible damage and improper operation of Check Valve and other equipment subject to heat damage. WHERE TO INSTALLYOUR FEEDER Series #300 and #302 are designed for EXISTING pools or spas or new pools or spas where conditions are such to make permanent installation into the return line impractical.the outlet line must be installed after the heater. If your pool does not have a heater, then it must be installed after the filter. (see Fig. A & B) DAMAGE TO YOUR HEATER COULD RESULT IF HIGHLY CHLORINATED WATER FLOWS THROUGH IT. If your pool has a heater, install the line to the feeder between the filter and heater. If your pool does not have a heater, install the inlet line between the pump and the filter. Refer to installation drawings A & B for your particular condition. Choose a site where feeder can be installed in a vertical position. Always install as far from any metal equipment as practical since fumes, etc. can corrode them. If optional corrosion resistant check valve is required, refer to installation instructions before next step. Position feeder close to filter and cut tubing to desired lengths. Be careful to cut ends straight. AlTACH INLET LINETO FEEDER Screw control valve into side of feeder. Use teflon tape to seal threads. Push compression nut over tubing and then push tubing onto tapered end of control valve. Tighten nut.firmly by hand. AlTACH OUTLET LINETO FEEDER Screw Combination check valve elbow into bottom of feeder. Refer to drawing on other side. Use teflon tape to seal threads. CAUTION, do not overtighten. Damage to threads or check valve could occur. Push compression nut over tubing end. Then push tubing onto tapered end of elbow.tighten nut firmly by hand. INSTALL INLET LlNE IN PLUMBING (Line to side of feeder). Turn off pump and timer switches. Drill 3/8" hole in plumbing, remove burrs and install saddle clamp assembly. See drawing on other side. Attach inlet line by first pushing compression nut over tub end. Then push tube onto tapered end of tube fitting. Tighten nut firmly by hand. INSTALL OUTLET LlNE IN PLUMBING (Line from feeder.) Drill 3/8" hole in plumbing (AFTER the heater. If no heater, drill after filter.) and remove burrs. See drawing on other side. Install saddle clamp assembly. Attach outlet line by first pushing compression nut over tube end. Then push onto tapered end of tube fitting. tighten nut firmly by hand. Installation is now complete. OPERATING INSTRUCTIONS Before start up of feeder, your pool should be properly conditioned and the residual should be 1.0 to 1.5 ppm, (Bromine ppm).the water in a newlyfilled pool should be properly conditioned to insure maximum effectiveness of the feeder. Consult your local dealer for water conditioning information for your area. 1. Remove cap of feeder and fill with proper size tablets. Series 300 uses 1" or 3" dia. tablets Series 302 uses 1 " dia. tablets in Spa Chamber. 2. Making sure 0-Ring is clean, lubricated with Lifegard Silicone and is in place, replace cap. Hand tighten only. 3. Turn on pump and timer switches. 4. Adjust control valve according to your poollspa size. Use a test kit. It is recommended that the chemical residual be checked daily for the first 5 days. Remember... hot days, higher water temperature or increased pollspa activity will cause your poollspa to use more sanitizer. When possible, increase the feed rate a day or two in advance. Because the sanitizer demand in your poollspa varies and is dependent on many factors (sunlight, bather load, water temperature, etc) your valve setting may have to be changed from time to time to adjust to these conditions. For example, the winter setting may be #2 while the summer setting is #3. Check the residual daily to find the ideal setting. Note: Higher numbers dispense more chemical. Small gradual changes are imperative for control. HOW TO RECHARGE FEEDER 1. Turn control valve to the closed position. SHUT OFF PUMP. 2. Wait one minute. This will allow water and fumes to drain from feeder. 3. Leave control valve closed and turn on pump.the check valve will prevent water from entering the feeder. 4. Remove cap and fill with proper size tablets or sticks. (See Operating Instructions #1) 5. Making sure 0-Ring is clean, lubricated with Lifegard Silicone and is in place, replace cap. Hand tighten only. 6. Open control valve to original setting. Inspect inlet and outlet line each time feeder is recharged. Replace lines yearly if necessary. BELOW WATER LEVEL INSTALLATION Feeder should be installed above water level whenever practical. If installed below water level, a drain valve must be installed to prevent spillage and dangerous splash back of high chlorinated water during recharging. Drill and tap a %" MPT hole at the same level the control valve is located. Make sure there is no water or tablets inside the feeder before drilling. Install optional drain valve, Part R172060, or suitable chemical resistant drain valve. BELOW WATER LEVEL RECHARGING INSTRUCTIONS 1. Shut off pump and timer switches. 2. Shut off control valve. 3. Place a clean container under drain and open drain valve. 4. Exercise extreme caution when opening or servicing feeder. Do not inhale fumes. Wear protective gear. Remove cap. Water will now drain from feeder. Empty container back into pool or spa. 5. Close drain valve. fill with proper size tablets or sticks. 6. Making sure 0-Ring is clean, lubricated with Lifegard Silicone and in place, replace cap. 7. Turn on pump and timer switches. 8. Reset control valve to original setting. lnspect inlet and outlet line each time feeder is recharged. Replace lines yearly if necessary. READ CAREFULLI This feeder is designed to use only Trichloro-s-triazinetrione OR Bromine tablets-slow dissolving type UNDER NO CIRCUM- STANCES mix Trichlor OR Bromine with Calcium Hypochlorite, with other forms of concentrated chlorine or with other chemicals FIRE AND EXPLOSION MAY RESULT. NEVER use oils or grease to lubricate O-ring. Oil in contact with Trichlor OR Bromine may result in fire. Lubricate O-ring with Lifegard Silicone O-ring Lubricant only, available at your dealer. Caution should be used when removing feeder cap. Do not inhale fumes. If shock treatments or Algaecides containing chemicals other than sanitizer tablets in feeder must be used, turn off Feeder OR remove tablets until the shock or Algae treatment is complete and all granuals have dissolved. Failure to do so may result in granules mixing in feeder causing FIRE AND/OR EXPLOSION. The shock or algae treatment dissolved in water is safe with tablets.

2 CAUTION Do not install feeder into copper plumbing. Pipe damage could occur. Never install feeder before heater. Heater damage could occur. Bromine Standpipe Installation To increase errosion of small Bromine tablets install Bromine Standpipe as follows: 1 Insert adapater (25) into check valve (20) opening end at bottom of chamber. 2. Push end of 6" tub (26) supplied into 14 adapater opening. FEEDER INLET LlNE If poollspa has heater, install between filter and heater. if no heater, install between pump and fllter. # CHLORINE 1 BROMINE FEEDER PARTS BREAK DOWN DRAWING Item Qtv. Part No. Description 1 1 R "Threaded cap 2 1 R Ring cap '3 1 R Check valve '4 1 R Chlorine control valve 5 8' R s" OD x %" ID tubing '6 1 R Male tube fitting %" NPT 8 1 R Female tube fitting %" NPT 9 2 R Tube fitting with nut 10 2 R Gasket 11 2 R Saddle clamp 12 1 R Body assy, wlstand #300 12A 1 R Body assy. wlstand # B 1 R Body assy. wlstand # C 1 R172035A Body assy. wlstand #302 '1 3 1 R " tube fitting-female %" NPT 14 1 R Spa chamber #302 only 17 1 R Cap wrench (optional) 18 1 R Control vane %" NPT x tube with nut 19 1 R Silicone lubricant 20 1 R Combination check valvelelbov 21 Optional R Flow indicator 23 Optional R Y2"-2" Corrosion resistant check valve 24 Optional R h" Corrosion resistant check valve 25 1 R B Standpipe adapter 26 1 R " Standpipe 31s OD x %" ID 'Used on earlier models (not shown) 3 IMPORTANT OPTION, SEE EQUIPMENT SAFETY SHEET Typical installation with heater FEEDER OUTLET LlNE If poollspa has heater, install afler heater. If no heater, install after filter. I p-20 YOU may substitute bromine tablets or sticks for trichlor in these feeders. DO NOT MIX. NSF listed for public or residential use in Swimming Pools, Spas or Hot Tubs using Trichlor or Bromine and when used with a flow indicating device such as Rainbow Lifegard u.s. Patent No & Model #R Canadian Patent No h Typical installation without heater RAINBOW,$, Pool Productsm

3 EXTENSIONS Going on vacation? Need more chlorine? Filling /Brominator too frequently? LIFEGARD CHLORINATOR EXTENSIONS SOLVE THE ABOVE PROBLEMS BY: 1. Increasing tablet capacity. 2. Larger chamber size allows more erosion of tablets. (See special instructions below) The 10" extension doubles and the 20" extension triples (approximately) the capacity and time between refills. *AVAILABLE THROUGH LIFEGARD DEALERS ONLY. NOTE: On free standing #300 series chlorinators, the base of the chlorinator should be secured to prevent the possibility of.the chlorinator tipping over due to increased height. 1. Follow recharging instructions to the point of filling with tablets 2. Making sure 0-Ring is clean, lubricated with Lifegard Silicone and in place, screw on extension tightly and secure with lock screw. (You may wish to wait until back in operation before tightening screw to insure against leaks). 3. Fill with tablets and continue with normal recharging procedure. SPECIAL INSTRUCTIONS: The large chamber size will result in more chlorine being dispensed at the same valve setting, therefore, once installed, several days monitoring will be necessary to readjust chlorinator output. *Does not apply to large capacity # or # Parts Breakdown Drawing Item Quantity Part No. Description 1 1 R Lockscrew (bottom collar) 2 1 R Ring 1 - #I #R 10" extension complete 20" extension complete Made & Printed in U.S.A. R

4 #R172323, #R & LRPE"R1#R CHECK VALVE NOTE: MAKE SURE ALL PUMPS AND TIMER SWITCHES ARE IN THE OFF POSITION. #R172323* '/4" CHECK VALVE & #R172324* I/z8' CHECK VALVE INSTALLATION: 1. Cut inlet line at desired location. 2. Slide compression nut over one end of line. Make sure arrow on check valve is pointing toward, insert barbed end of check valve into line and tighten the nut finger tight. Repeat procedure for other end of check valve. #R l/2"-2" CHECK VALVE INSTALLATION: 1. Cut piping at required location for your situation (refer to drawings). 2. Making sure arrow on check valve is pointing away from equipment and in the direction of water flow to the poollspa, glue in check valve using PVC solvent cement. 1%" pipe will glue directly in valve, 2" pipe requires two 2" slip x slip couplings WITH HEATER Suct~on from poollspa "Note: For greater flow rate, inlet line may be installed between filter and pump. #R172323' 'A" Check Valve #R172324' %" Ch NOTE: If heaters are used, a FIREMAN'S SWITCH or equivalent must be installed to prevent possible damage and improper operation of CHECK VALVE and other equipment subject to heat damage. WITHOUT HEATER #R172323' %" Check Valve or #R172324' Yz" Check Valve Suction from poollspa 6 " Chlorir~ator Ch!orinator 1 Y2"-2" Check Valve Outlet line EQUIPMENT SAFETY CAUTION PLEASE READ CAREFULLY Since most pool plumbing is not airtight, and a mixture of air and chlorine is highly corrosive to metals, it is important to protect these items from corrosion in the OFF period when no circulation is taking place. (There is no chance for chlorine corrosion when the circulating system is in operation.) Of course, corrosion or erosion of metal components can still occur independently of any chlorinator installation for the following reasons: 1. Water velocity too high. 2. Water ph less than Total alkalinity less than 100 PPM. If your pool or spa has any of the following equipment, special plumbing procedures must be followed for safe operation: 1. Brass or bronze gate, rotary or backwash valves. 2. The preceding valves constructed of PVC or other plastic material with metallic shafts. 3. Filters, heaters, heat exchanges or other items with metallic tanks, shafts, coils or tubes. 4. NOT FOR USE IN COPPER PLUMBING. Installation of the OPTIONAL Rainbow #R172288, #R172323* and #R172324* positive seal, corrosion resistant check valve SHOWN ON REVERSE SIDE will prevent the backflow of corrosive liquids and gases that can damage equipment containing metallic components. Examples listed above. *Note: Valve size and tubing size must match. WARNING: If your pool is equipped with a permanent built in pool-cleaning system, damage could occur to that system if materials are not compatible with low ph Tri-Chloro feeders. Check with manufacturer for compatibility. Made & Printed in U.S.A. R

5 #300=29X CHLORINEIBROMINE FEEDER For commercial-size applications Features: No special venting required. Completely enclosed-no escaping. -- gases. positive external no-clog chlorine control valve. No equipment damage. Feeds sanitizer directly to pool or spa. All parts replaceable. WHERETO INSTALLYOUR FEEDER IFYOUR POOL OR SPA HAS COPPER PLUMBING... STOP!! Never ~nstall Ihe feeder into copper plumbing as pipe damage could occur. Feeder should be installed ABOVE POOL WATER LEVEL whenever practical If installed below water level these special instructions must be followed for safe and proper operation. When the feeder is installed below water level, two conditions must be overcome 1, ISOLATION OFTHE FEEDER FROM POOL WATER: The control valve when shut off to "off" isolates it on the side. A one way check valve such as the Rainbow R172324NS or other chemicallv resistant check valve will have to be attached on the discharoe line at the top of the feeder. NOTE: Never use any type of isolation valve on the d~scharge or outlet side of the feeder. Damage to the feeder will occur due to pressure build up Use only a one-way corrosion resistance check valve. If isolation valves are used, remember to open them as soon as possible following recharging. Never leave closed for long periods of time as pressure will bu~ld up. Isolation is necessary to accomplish "DRAINING" in condition #2 which follows 2. DRAINING: To prevent dangerous splash back of highly chlorinated water during recharging, the feeder will have to be emptied There is a %" MPT plug on side of feeder (see drawing) that can be removed for draining To facilitate draining: A dram valve IS available from your dealer. Details on back drawlng. The outlet lhne must be installed after the heater. If your pool does not have a heater, then it must be installed after the fllter. DAMAGE TO YOUR HEATER COULD RESULT IF HIGHLY CHLORINATED WATER FLOWS THROUGH IT. REFER TO INSTALLATION DRAWING FIGURE A Install the inlet llne between the pump and filter. Detailed installation instructions follow ~n the next section. IMPORTANT PLUMBING HINTS All male pipe fittings must be wrapped with 3-4 turns of teflon tape to act as a thread sealant Always wrap counter-clockwise (opposite of direction to tighten) Never overtighten fittings, they are plastic and can be broken. Usually 2-3 turns past finger tight will prevent any leaks. A fitting can always be tightened more 11 it leaks but not once it IS broken Additional saddle clamps (Part No. R172264) may be required if plumbing is over 2" in diameter. Clamps can be interlocked For plumbing 3" to 6" diameter, order saddle clamps (Part No R172264XL). It is recommended that the Feeder be bolted down.) 1 Position feeder close to the filter and cut tubing to desired length. Be careful to cut tubing ends straight 2. AlTACH INLET LlNE TO FEEDER. Wrap %" x short nipple with teflon tape. Screw nipple into bottom %" FPT hole in side of feeder. Screw control valve onto other end of nipple Be careful not to overtighten. Wrap 90 degree tube fitting with teflon tape and screw into valve Push compression nut over tubing end of elbow. Push tubing onto tapered end of elbow. Tighten nut firmly by hand. SEE DRAWING ON OTHER SIDE OF INSTRUCTION SHEET. 3. AlTACH OUTLET LlNE TO FEEDER. Wrap 90 degree fitting with teflon tape and screw into top 'iz" FPT hole on side of feeder. Push compression nut over tubing end, then push tubing onto tapered end of elbow. Tighten nut firmly by hand. 4 INSTALL INLET LlNE IN PLUMBING. (Line to bottom side of feeder).turn off pump and tlmer switches. Drill 9/16" hole in plumbing, remove burrs and install saddle clamp assembly. Secure tubing to saddle clamp f~tting by tightening clamp. Make sure clamp is below rib at end of saddle fltting. SEE DRAWING FIGURE A. 5. INSTALL OUTLET LlNE IN PLUMBING. (Line from top of feeder.) Drill 9/~6" hole in plumbing AFTER the heater and remove burrs. SEE DRAWING FIGURE A. Install saddle clamp assembly Attach tubing as in #4 above, Installation is now complete. SEE INSTALLATION DRAWING FIGURE A ON OTHER SIDE. DIRECTIONS FOR USE Before start up of feeder, your pool should be properly conditioned and the chlorine residual should be 1.0 to 1.5 ppm, (Bromine ppm). The sanitizer demand in a pool varies and is dependent (upon many factors; sunlight, bather load, water temperature, etc. As a result, the valve setting may have to be changed from time to time to conform to conditions. For example, the winter setting may be 2 and the summer setting may be 3. Recommended start setting #3. Check residual daily to find ideal valve setting. Note: Higher numbers dispense more sanitizer. START UP INSTRUCTIONS Exerclse extreme caution when opening or servicing feeder. Do not inhale fumes. Wear protective gear. Follow manufacturer's suggestions for handling the chemical. 1. If below water level, close the control valve and drain any water in feeder by removing '/in NPT plug in bottom, or by opening valve on optional drain kit. After draining, reinstall plug (use teflon tape) or close drain valve. 2. Remove cap of feeder and fill with Trichlor or bromine tablets. For maximum dispensal rate use 1" diameter tablets, 3" tablets produce less than 40% of 1" tablets. 3 Making sure 0-Ring is clean, lubricated with Lifegard Silicone and is in place, replace cap Hand tighten only. 4. Turn on pump and timer switches. Open control valve to #5 for one minute; which will allow feeder to fill with water. Adjust control valve according to your pool's size. Larger numbers dispense more sanitizer. The water in a newly filled pool should be properly conditioned to ensure maximum effectiveness of the Lifegard Automatic Feeder. Consult your local pool dealer for water conditioning information in your area. Refer to tablet container for recommended residual. It is recommended that the sanitizer level be checked daily for the first 5 days. Remember that on hot days higher water temperature or increased pool activity will cause your pool to use more sanitizer. When possible, increase the feed a day or two in advance. HOWTO RECHARGE 1. SHUT OFF PUMP AND TIMER SWITCHES. OPEN CONTROL VALVE TO #5 (I: below water, level, see special instructions below.) 2. Remove cap; this will allow water and fumes to drain from feeder. 3. Fill with PROPER SIZE TABLETS (SEE START UP INSTRUCTIONS #2) 4. Mak~ng sure 0-Ring is clean, lubricated with Lifegard Silicone and is in place, replace cap. Hand tighten only 5. Turn on pump and timer switches. 6. Leave control valve on #5 for one minute, this will allow feeder to fill with water. Reset control valve to original settlng, lnspect inlet and outlet lines each time feeder is recharged. Replace lines yearly if necessary Model X may require drain kit part #R and a corrosion resistant check valve part #R (See illustration) BELOW WATER LEVEL RECHARGING INSTRUCTIONS 1. Shut off pump and timer switches. 2. Shut off control valve. 3. Place a clean container under drain and open drain valve. 4. Exercise extreme caution when opening or servicing feeder. Do not inhale fumes. Wear protective gear. Remove cap. water will now drain from feeder. Empty container back into pool or spa. 5 Close drain valve. Follow chemical manufacturets recommendations for handling chemical used in your feeder. Fill with proper size tablets or sticks. 6 Making sure 0-Ring is clean, lubricated with Lifegard Silicone and is in place, replace cap Hand tighten only. 7. Turn on pump and timer switches. 8. Reset control valve to original setting, lnspect inlet and outlet lines each time feeder is recharged. Replace lines yearly if needed. READ CAREFULLY This feeder is designed to use only Trichloro-s-triazinetrione OR Bromine tablets-slow dissolving type UNDER NO CIRCUM- STANCES mix Trichlor OR Bromine with Calcium Hypochlorite, with other forms of concentrated chlorine or with other chemicals FIRE AND EXPLOSION MAY RESULT. NEVER use oils or grease to lubricate 0-Ring. Oil in contact with Trichlor OR Bromine may a result in fire. Lubricate 0-Ring with Lifegard Silicone 0-Ring Lubricant only, available at your dealer. Caution should be used when removing feeder cap. Do not inhale fumes. If shock treatments or Aigaecides containing chemicals other than sanitizer tablets in i feeder must be used, turn off Feeder OR remove tablets until the shock or Algae treatment is complete and all granuals have i dissolved. Failure to do so may result in granules mixing in feeder causing FIRE AND/OR EXPLOSION. The shock or algae treat- 1 rnent dissolved in water is safe with tablets.

6 CAUTION #300-29X CHLORINE / BROMINE FEEDER DO not install feeder into copper PARTS BREAK DOWN DRAWING plumbing. Pipe damage could occur. Item Qty. Part No. Description Never install feeder before heater. 1 1 R172G08 3" Threaded cap Heater damage could occur. 2 1 ~ ~ing cap 3 1 R %" x Short MPT nipple 4 1 R M" Chlorine control valve 5 2 R %" 90" NPT x tube fitting win1 6 12' R %"ID Chrlorinator tube 7 2 R SIS tubing clamp 8 2 R Saddle tube fitting 9 2 R Saddle gasket 10 2 R Saddle clamp?2 1 R Body assy wlstand #35G R Silicone lubricant 14 Optional R Cap Wrench 15 1 R172324NS %" Corrosion res~stant check 9/16" HOLE IN PLU CHECK VALVE FOR valve, tube x tube (ball) HEATER, IF NO HE BELOW LEVEL 16 1 R Vz" MPT PVCplug INSTALLATION 17 Optional R %"-2" Corrosion resistant check valve 9/16" HOLE IN PLUMBING - BETWEEN PUMP &FILTER FEEDER HEATER FILTER FIG. A L,., Typical Installation with Heater OPTIONAL If Flow indicator is used, a draln FLOW INDICATOR kit IS required (See Insert above OPTIONAL DRAINVALVE KIT #R KIT INSTALLATION optional drain kit). A R %" x Short MPT nlpple B R '12" Control valve C R %" 90" MPT x tube fitting wlnut YOU MAY SUBSTITUTE BROMlhlE TABLETS OR STICKS FOR TRICHLOR IN THIS FEEDER. DO NOT MIX. NSF listed for publ~c or reslderltial use in Swimm~ng Pools. Spas or Hot T11bs using Trichlor or Bromlne and when used uith a flow indicating device such as Rainbow Lifegard Model 2R CORROSION RESISTANT FLOW INDICATOR KIT No. R Item Part No Oty Dercrtptloil 1 R Commercial Flow Indicator 1A R '/2" coupling (included with Flow indicator) 2 R K" x 90" Elbow FP? 3 R %" x 90" NP? x tube fitting with nut 4 R Saddle clamp with inlet fitting 5 R Saddle gasket 6 R M" corrosion resistant check valve, tube x tube U.S. Patent No & Canadian Patent No. 1092

7 EXTENSIONS Going on vacation? Need more chlorine? Filling Ct-~lorinator/Brominator too frequently? LIFEGARD CHLORINATOR EXTENSIONS SOLVE THE ABOVE PROBLEMS BY: 1. Increasing tablet capacity. 2. Larger chamber size allows more erosion of tablets. (See special instructions below) The 10" extension doubles and the 20" extension triples (approximately) the capacity and time between refills. *AVAILABLE THROUGH LIFEGARD DEALERS ONLY. NOTE: On free standing #300 series chlorinators, the base of the chlorinator should be secured to prevent the possibility of the chlorinator tipping over due to increased height. 1. Follow recharging instructions to the point of filling with tablets 2. Making sure 0-Ring is clean, lubricated with Lifegard Silicone and in place, screw on extension tightly and secure with lock screw. (You may wish to wait until back in operation before tightening screw to insure against leaks). 3. Fill with tablets and continue with normal recharging procedure. SPECIAL INSTRUCTIONS: The large chamber size will result in more chlorine being dispensed at the same valve setting,.therefore, once installed, several days monitoring will be necessary to readjust chlorinator output. *Does not apply to large capacity # or # Parts Breakdown Drawing Item Quantity Part No. Description 1 1 R Lockscrew (bottom collar) >c:,::.- -7 :; " extension complete 20" extension complete Made & Printed in U.S.A. R

8 ~~!~~ # R ~~~~~ VALVE FOR #300-29X CHLORINATOR: USE #I Y2" CHECK VALVE INSTEAD OF #I %" CHECK VALVE AS SHOWN NOTE: MAKE SURE ALL PUMPS AND TIMER SWITCHES ARE IN THE OFF POSITION. #R172323* '/4" CHECK VALVE & #R172324* 1/2" CHECK VALVE INSTALLATION: 1. Cut inlet line at desired location. 2. Slide compression nut over one end of line. Make sure arrow on check valve is pointing toward, insert barbed end of check valve into line and tighten the nut finger tight. Repeat procedure for other end of check valve. #R Yz"-2" CHECK VALVE INSTALLATION: 1. Cut piping at required location for your situation (refer to drawings). 2. Making sure arrow on check valve is pointing away from equipment and in the direction of water flow to the poollspa, glue in check valve using PVC solvent cement. 1 %" pipe will glue directly in valve, 2" pipe requires two 2" slip x slip couplings WITH HEATER fi-4 suction from poo~spa 6 - r n "Note: For greater flow rate, inlet line may be installed between filter and pump. NOTE: If heaters are used, a FIREMAN'S SWITCH or equivalent must be installed to prevent possible damage and improper operation of CHECK VALVE and other equipment subject to heat damage. WITHOUT HEATER #R172323* %" Check Valve or Outlet line, XR172324' h" Check Valve I " inlet line fi=,) Heater I 1 p-1 # %"-2" Check Valve " Outlet line #R172323* %" Check Valve #R172324' %" Check Valve - I Suction from poollspa h - rn 1 %"-2" Check Valve Return line to poollspa EQUIPMENT SAFETY CAUTION PLEASE READ CAREFULLY Since most pool plumbing is not airtight, and a mixture of air and chlorine is highly corrosive to metals, it is important to protect these items from corrosion in the OFF period when no circulation is taking place. (There is no chance for chlorine corrosion when the circulating system is in operation.) Of course, corrosion or erosion of metal components can still occur independently of any chlorinator installation for the following reasons: 1. Water velocity too high. 2. Water ph less than Total alkalinity less than 100 PPM. If your pool or spa has any of the following equipment, special plumbing procedures must be followed for safe operation: 1. Brass or bronze gate, rotary or backwash valves. 2. The preceding valves constructed of PVC or other plastic material with metallic shafts. 3. Filters, heaters, heat exchanges or other items with metallic tanks, shafts, coils or tubes. 4. NOT FOR USE IN COPPER PLUMBING. Installation of the OPTIONAL Rainbow #R172288, #R172323' and #R172324' positive seal, corrosion resistant check valve SHOWN ON REVERSE SIDE will prevent the backflow of corrosive liquids and gases that can damage equipment containing metallic components. Examples listed above. 'Note: Valve size and tubing size must match. WARNING: If your pool is equipped with a permanent built in pool-cleaning system, damage could occur to that system if materials are not compatible with low ph Tri-Chloro feeders. Check with manufacturer for compatibility.

Ozone Generator Systems

Ozone Generator Systems PZ2-1 & PZ2-2 - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal

More information

Ozone Generator Systems

Ozone Generator Systems PZ2-4V - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear

More information

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series PZ2 Series Manual PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems INSTALLATION GUIDE and OPERATION MANUAL Prozone PZ2 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.

More information

PZ1, PZ3 & PZ6 Installation Guide

PZ1, PZ3 & PZ6 Installation Guide PZ1, PZ3 & PZ6 Installation Guide PROZONE INTERNATIONAL, INC. Ozone Water Purification Systems INSTALLATION GUIDE Prozone PZ1, PZ3 and PZ6 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.

More information

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES May be cleaned and reused before replacement is necessary. Cartridge cleaning

More information

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions? Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Clean Water Made Easy

Clean Water Made Easy Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine

More information

EcoMaster - Residential Pools up to 40,000 Gallons

EcoMaster - Residential Pools up to 40,000 Gallons - Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water Copyright 2013 Prozone Water Products: 3004 11 th Ave. -

More information

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION ClearChoice Economy Under Sink Drinking Water System OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION Congratulations on the purchase of your ClearChoice

More information

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference. FOR THE RECORD You should record the model and serial numbers, which can be found on the back of the unit, for future reference. Warranty: 18 mo. on unit and 1 year on check valve assembly Model: The Ozone

More information

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions 215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...

More information

Clean Water Made Easy

Clean Water Made Easy Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 1650 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning

More information

FLECK 5600 WATER SOFTENER INSTALLATION

FLECK 5600 WATER SOFTENER INSTALLATION FLECK 5600 WATER SOFTENER INSTALLATION Discount Water Softeners recommends using a licensed plumber to install your water softener. The following installation instructions are for use with the water softener

More information

Important Safety Instructions

Important Safety Instructions 8 THE BUBBLE MIST STOPS COMING BACK INTO THE POOL: Note: Our suction side installation method requires a portion of the pump s power. Anything affecting the pump s performance affects our air draw. Under

More information

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA OzoneAX 3 T Vacuum-ultraviolet Ozone Systems Installation & Operation anual odel OZ-SPA A. Important Safety Instructions IPORTANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety

More information

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

4-1 1 / 2  Tees / 2  hole saw w/ 1/4 drill bit / 2  Male slip plugs Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union

More information

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available

More information

SMF PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL SMF PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions

More information

Installing the Turbo Floor Model System

Installing the Turbo Floor Model System Installing the Turbo Floor Model System Location 1. Locate as close as possible to water supply source. 2. Locate as close as possible to a three-prong grounding receptacle. 3. Locate the System on a smooth

More information

EcoMaster - Residential Pools up to 40,000 Gallons

EcoMaster - Residential Pools up to 40,000 Gallons - Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water PROZONE Copyright 2018 Prozone Water Products: 3004 11 th

More information

5700-E Sediment Filter Installation & Start-Up Guide

5700-E Sediment Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1 Introduction The Bottom Feed solar water heater connector is meant to connect solar water heater panels directly to your existing standard water heater. It's main advantages are ease of installation, efficiency,

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

Installation & Service Guide

Installation & Service Guide Reverse Osmosis Ontario Soft Water.ca Kitchener, Canada 519-579-0500 Installation & Service Guide Pentair 75 gpd Encapsulated Membrane System Standard System 75gpd Membrane Your New Reverse Osmosis System

More information

Kinetico 2060f OD Sulfur Guard Installation Instructions

Kinetico 2060f OD Sulfur Guard Installation Instructions SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.

More information

Fleck 2510 Sediment Filter Installation & Start-Up Guide

Fleck 2510 Sediment Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance

More information

CHAMPION PUMP OWNER S MANUAL

CHAMPION PUMP OWNER S MANUAL CHAMPION PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com

More information

Installation Manual PS-200 & PS-201

Installation Manual PS-200 & PS-201 Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

Parts & Material Included

Parts & Material Included O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer

More information

Fleck 5600 Carbon Filter Installation & Start Up Guide

Fleck 5600 Carbon Filter Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com Fleck 5600 Carbon Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

Fleck 2510 SXT Catalox Installation & Start Up Guide

Fleck 2510 SXT Catalox Installation & Start Up Guide Fleck 2510 SXT Catalox Installation & Start Up Guide For Catalox Filters with PotPerm Bleach Solution Tank Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Installation Manual PS-225 & PS-275

Installation Manual PS-225 & PS-275 Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

Hydrotherapy Jets (Remote Water Quality System)

Hydrotherapy Jets (Remote Water Quality System) Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree

More information

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION I -, 3. -is INSTALLATION AND OPERATION INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM e Coo/ah AMERICAN COOLAIR CORPORATION TABLE OF CONTENTS PAGE I. CONCEPT OF EVAPORATIVE COOLING....2 II. RECOMMENDEDTOOLS......3

More information

Clean Water Made Easy

Clean Water Made Easy Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 2510 Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine

More information

SuperKlean Washdown Products

SuperKlean Washdown Products February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT

More information

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2 Professional Series Chemical Feed System Model # 22152-02 US Patent No. 6,752,930 B2 Product Manual SureWater Technologies, Inc. The Solution X-2 Model # 22152-02 Table of Contents 1. Installation Instruction

More information

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08 EFFECTIVE: MAY, 2014 American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 The American Dish Service part numbers contained in this

More information

WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET

WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET 1. BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials,

More information

7800 Neutralizer Installation & Start-Up Guide

7800 Neutralizer Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com 7800 Neutralizer Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your

More information

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 Owner s Manual Keep with machine for reference PKC24 INSTALLATION & OPERATION REV.11.09 Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 800-558- 5592 FAX 414-353- 7069 perlick.com TABLE OF

More information

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL 1 INTRODUCTION Congratulations on choosing Permatech to improve the quality of your water. You will immediately begin to notice the numerous benefits of having

More information

CWS Plus Sediment Filter Installation & Start Up Guide

CWS Plus Sediment Filter Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com CWS Plus Sediment Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VARIABLE SPEED BOOSTER PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION WARNING: RISK OF ELECTRICAL SHOCK

More information

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener Installation, Operation, and Maintenance Manual Waterlogix Metered Residential Water Softener Waterlogix WLS-075 Waterlogix WLS-075C Waterlogix WLS-100 Waterlogix WLS-100C Waterlogix WLS-150 Waterlogix

More information

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions? Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Tannin Filter Installation & Startup Guide For Tannin Filters with Vortech Distributor Screen Thank you for purchasing a Clean Water System! With

More information

ENCLOSED UNIT TECHNICAL MANUAL Items # &

ENCLOSED UNIT TECHNICAL MANUAL Items # & R ENCLOSED UNIT TECHNICAL MANUAL Items #91163-00 & 91164-00 The Green Earth II Enclosed Unit is a modular, locking dispensing system that allows the user to dispense chemicals safely. It also has the flexibility

More information

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all

More information

Installation and Operation Manual

Installation and Operation Manual How To Install, Operate and Maintain Your Reverse Osmosis System INSTALLERS: PLEASE READ ALL INSTRUCTIONS BEFORE IN- STALLING AND USING THIS SYSTEM. IT IS RECOMMENDED TO WAIT UNTIL THE ENTIRE SYSTEM IS

More information

WATER PURIFYING SYSTEM

WATER PURIFYING SYSTEM ECO FRIENDLY PARAMOUNT CERTIFIED WATER PURIFYING SYSTEM INSTALLATION MANUAL 004-027-8818-00 REV 060116 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate

More information

TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL

TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL Water Systems, LLC www.123filter.com Email: sales@123filter.com TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL Model #RCB4T ABOUT THE SYSTEM Reverse Osmosis process is a separation process. Tap water enters

More information

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this: Installation Guide Before you assemble your new system, be sure that the following conditions have been met for placement of your softener: Getting Started Level, firm surface, such as concrete, on which

More information

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop APEX Water Filters pure water in every drop MODEL RO 5 INSTRUCTION MANUAL Treat your body to pure goodness with Apex filtered water A Water supply adapter valve B Cold water shut-off valve C Hot water

More information

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

Installation Guide. Inline Chlorinator TM. Vitasalus, Inc Rankin Drive Troy, Michigan USA

Installation Guide. Inline Chlorinator TM. Vitasalus, Inc Rankin Drive Troy, Michigan USA Vitasalus, Inc. 248-585-8815 1301 Rankin Drive Troy, Michigan 48083 USA www.vitasalus.com Congratulations on your purchase of the Water Treatment and Disinfection System, an effective easy to use chorine

More information

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS IMPORTANT! Read all of these instructions before installing the dishwasher. AUTOMATIC HIGH LOOP The drain hose is fastened to the back of the machine at the

More information

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating

More information

OWNERS GUIDE TO INSTALLATION AND OPERATION

OWNERS GUIDE TO INSTALLATION AND OPERATION OWNERS GUIDE TO INSTALLATION AND OPERATION SPM SERIES HIGH POWER CENTRIFUGALS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump. Be sure to check

More information

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS CATALOG NO.: 6100.53O Effective: 03-15-05 Replaces: 02-01-05 INTRODUCTION The SPA-PAK Spa Heaters have been designed to provide efficient,

More information

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing INSTALLATION & OPERATIONS MANUAL FOR Z0-910/912 OZONE SYSTEM FOR IN-GROUND POOLS New and Existing MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0454-041900/03 IMPORTANT SAFETY

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series PumpAgents.com - Click here for Pricing/Ordering Model 6050-Series SELF-PRIMING PUMPS FEATURES Body: Impeller: Shaft: Wearplate: Shaft Seal: Ports: Motor: Weight: Bronze Construction JABSCO Nitrile 316

More information

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual TITAN VI High Efficiency Water Conditioner Installation and Operation Manual Manufacturer s Warranty Holts Water Conditioning 369 South Mountainway Drive Orem, UT 84058 801-426-9243 To the original purchaser,

More information

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and

More information

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3. 4.4 SUPPLY PUMPAK ASSEMBLY NOTE: This section applies only to systems, which include a supply pumpak. Only the H6, XA, and XC series systems contain a supply pumpak. If your system is a single zone, H6

More information

Clean Water Made Easy

Clean Water Made Easy Clean Water Made Easy www.cleanwaterstore.com CWS Plus Neutralizer/Birm Blend Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine

More information

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate Instructions Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate 332517B EN For adapting a 60# Dyna-Star Pump for use with a 35# bucket. For professional use only. Part No.: Important Safety Instructions

More information

SYSTEMS for CATALYTIC FILTERS

SYSTEMS for CATALYTIC FILTERS OP40U5F, OP40B5F, OP80U10F, OP80B10F, OP120U15F & OP120B15F INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Hydrogen Sulfide Removal SYSTEMS for CATALYTIC FILTERS NO DIAPHRAGMS OR AIR CELLS COMPLETELY CORROSION

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

Acrylic Claw Foot Tub

Acrylic Claw Foot Tub Acrylic Claw Foot Tub Wrench or socket Drill & Bits Parts Recommended 2-2 x12 boards 4 Lag Bolts 4 Flat Washers Be sure to re-inforce the floor before securing tub. We recommend 2-2 x12 s securely fastened

More information

One Less Thing to Forget...

One Less Thing to Forget... Installation Guide One Less Thing to Forget... Sign up now for cartridge auto-renew and save 10%! Stop stressing about when to purchase your next nuvoh2o replacement cartridge. Sign up for our auto-renew

More information

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS Models: DM-813-PLLL-1T DM-813-PDLL-1T DM-813-PLLL-2T DM-813-PDLL-2T I-729 Pg 1 of 15 System Overview The DEMA DEMAMaster probeless series is designed

More information

COBRA -300H EXTRACTOR

COBRA -300H EXTRACTOR COBRA -300H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always

More information

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com

More information

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here: DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com

More information

INSTRUCTION MANUAL with Replacement Parts

INSTRUCTION MANUAL with Replacement Parts INSTRUCTION MANUAL with Replacement Parts MODEL FD500 FOOD WASTE DISPOSERS (INCLUDES MOTOR PARTS) ML-18978 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 11394 Rev. G (10-98)

More information

SAN JUAN FRESH WATER COOLING SYSTEMS

SAN JUAN FRESH WATER COOLING SYSTEMS SAN JUAN FRESH WATER COOLING SYSTEMS 4.3-5.7 GI VOLVO Block Only Cooling, Mounted Off Engine Kit #V-111 Installation Instructions San Juan Engineering Heat Exchangers provide thermostatically controlled

More information

QUIETFLO OWNER S MANUAL

QUIETFLO OWNER S MANUAL QUIETFLO OWNER S MANUAL INSTALLATION, OPERATION & PARTS To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completley. CAUTION - We highly recommend a qualified

More information

HE120, HE160 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and

More information

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual TITAN VI Pro-Max Manufacturer s Warranty Holts Water Conditioning 369 South Mountainway Drive Orem, UT 84058 801-426-9243

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TECHNICAL INSTRUCTIONS 24-Month Maintenance Kit P/N 58015-02 For BMK2.0 (Nozzle Mix) Description of Document: This TID provides the procedures to perform recommended 24-Month maintenance on the following

More information

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU BURGER KING BKSDU Burger King Shortening Disposal Unit (BKSDU) Operation, Service & Parts Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified

More information

Alkaline RO System INSTALLATION MANUAL

Alkaline RO System INSTALLATION MANUAL Alkaline RO System INSTALLATION MANUAL 1-800-992-8876 Customer Support Disclaimer All rights reserved. All material published on this site by Express Water Inc., including all portions of the website,

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Built-In Dishwasher Dishwashers Write the model and serial numbers here: Model # Serial # You can find them on the tub wall just inside the door or. the lower part of back. Installation Instructions DDW1802W

More information

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~ WATERSHIELIJrM REVERSE OSMOSIS SYSTEM INSTALLA TION MANUAL p 1 ~ -~ I IMPORTANT I ITHIS REVERSE OSMOSIS SYSTEM WAS SOLD IN KIT FORM. IT HAS ~ INOT BEEN PRESSURE TESTED IN ANY WAY. UPON INSTALLATION IT

More information

Arch Feeder: Installation Manual

Arch Feeder: Installation Manual Arch Feeder: Installation Manual Model #A300N Arch Chemicals, Inc. 1200 Lower River Road, P.O. Box 800 Charleston, TN 37310-0800 Product Stewardship MAKING THE WORLD A BETTER PLACE Arch is committed to

More information

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Date 10/08 Introduction IOD150,IOD200,IOD250

More information

Model LF-310 Air Operated

Model LF-310 Air Operated Microflush Half Gallon Toilets Model LF-310 Air Operated Installation/Service Manual P/N 24156 452 East Hill Road Fax: 707.459.6617 Willits, CA 95490 USA E-mail: info@microphor.com Phone: 707.459.5563

More information

Teflon Rotary Drum Pump

Teflon Rotary Drum Pump Operating Instructions & Parts Manual 6005 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key ASSEMBLY and INSTALLATION INSTRUCTIONS Gas Conversion Kit Tube Heaters View these instructions online at www.lbwhite.com Kit Contents: DESCRIPTION QTY. Instructions 1 Burner orifi ce 1 Manifold pipe 1

More information

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt, Aqua-Pure is a market leader in water filtration. In addition to our comprehensive range of Domestic Water Purifiers, we design and manufacture an extensive commercial and industrial range of purification

More information

Installation Guide Europa

Installation Guide Europa Installation Guide Europa One Less Thing to Forget... Sign up now for cartridge auto-renew and save 10%! Stop stressing about when to purchase your next nuvoh2o replacement cartridge. Sign up for our auto-renew

More information

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

NOTE: Parts are no longer available for this tool. The manual will continue on the next page. NOTE: Parts are no longer available for this tool. The manual will continue on the next page. ------------------------------------------------- CATALOG NO. 7628 Form No. Z21 0 Date 1-93 High Pressure Power

More information