1 Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate with the EcoNet Smart Home System. The RHT*E features an Electronic Expansion Valve (EEV) The RHT features a Constant Torque Two-stage motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing. Versatile -way convertible design for upflow, downflow, horizontal left and horizontal right applications. Factory-installed indoor coil. Sturdy cabinet construction with 1.0 inch [. mm] of foil faced insulation for excellent sound and insulating characteristics. Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cul requirements for service disconnect. 1 1 / ton [. kw] through ton [17.6 kw] models are between 1 / to 7 inches [1080 to 18 mm] tall and inches [9 mm] deep. All models meet or exceed 0 to 00 CFM [16 to 189 L/s] per ton at. inches [.7 kpa] of external static pressure. Enhanced airflow up to.7" external static pressure. Suitable for application in mobile homes. FORM NO. H11-6 REV.
2 Table of Contents TABLE OF CONTENTS Engineering Features... Model Number Identification... Dimensional Data...-6 Airflow Directional Data...7 Airflow Performance Data Electrical Data Electrical Wiring...19 Accessories...19 Limited Warranty...0
3 Engineering Features Engineering Features RHT- Series Equipped standard with an EcoNet Air Handler control board that allows it to directly communicate with the EcoNet Control Center. The EcoNet Control Center serves as the hub of communication for a home s Heating, Cooling, and Water Heating systems, and is required to operate an EcoNet Enabled Heating and Cooling system in fully communicating mode. An EcoNet WiFi kit can be added to the EcoNet network and will use the homeowner s wireless network and broadband Internet connection to enable remote operation of EcoNet Enabled equipment from the mobile-friendly web portal or mobile apps. Selected models equipped with an electronic expansion valve (EEV), which can intelligently change the EEV position based on system demands. By the measurement of the suction pressure via the vapor line pressure transducer (factory installed) and the vapor line thermistor (field connected to the vapor line, but factory provided within the air handler) the EcoNet enabled air handler control calculates the suction superheat at the indoor coil. This calculation permits the air handler control to make decisions for when to open and close the EEV for the purpose of maintaining a predetermined suction superheat. The EEV is equipped with a -pole removable external stator, and inlet and outlet chatleff fittings for optimal serviceability. These valves also have an internal check valve to provide heat pump compatibility. When operating in heating mode, the air handler control will open the EEV completely to permit the check valve to operate and maximize reverse refrigerant flow. The most compact unit design available, all standard heat air handler models only 1 / to 7 inches [1079 to 18 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to inches [1 mm] for 1 1 / inch [8 mm] conduit. Front refrigerant and drain connections.
4 Model Number Identification R H T 17 S E A C J A *** Option Code (see ADS-80) Blank = None Minor Series A = First Voltage A = 11/1/60 D = 80V//60 J = 08/0/1/60 Controls C = Communicating N = Non-Communicating Major Series A = First Metering Device T = TEV E = EEV P = Piston Coil Efficiency S = Standard M= Medium H = High Width 17 = 17." [1.8 mm] ( CFM) 1 = 1" [. mm] ( CFM) =." [609.6 mm] ( CFM) Nominal Capacity = 18,000 [.7 kw]-,000 [7.0 kw] BTU/H 6 = 0,000 [8.79 kw]-6,000 [10. kw] BTU/H 8 =,000 [1.1 kw]-8,000 [1.06 kw] BTU/H 60 = 60,000 [17.8 kw] BTU/H Type T = Constant Torque (ECM) Stages of Air Flow 1 = Single = Two Stage V = Variable Speed Product Category H = Air Handler Rheem Available EEV Models at J Voltage RHT17SEACJA RHT1MEACJA RHT617SEACJA RHT61MEACJA RHT81MEACJA RHT601SEACJA RHT60MEACJA Available TEV Models at J Voltage RHT1MTACJA RHT61MTACJA RHT81MTACJA RHT60MTACJA
5 Unit Dimensions Return Air Opening Dimensions Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches) /8 19 / 1 19 /8 19 / 7 /8 19 / Air Dimensional Data ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7 /8 [. mm], 1 / [7.8 mm], 1 1 / [0 mm] DIA. KNOCKOUTS. SUPPLY AIR 10 /16 [6 mm] NOTE: CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. W LOW VOLTAGE CONNECTION /8 [1.9 mm] AND 7 /8 [. mm] KNOCKOUT A H AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) UPFLOW/DOWNFLOW APPLICATION ONLY LIQUID LINE CONNECTION COPPER (SWEAT) 19 1 / [9 mm] RETURN AIR OPENING 1 11 /16 [1 mm] VAPOR LINE CONNECTION COPPER (SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. Unit Dimensions & Weights Model Size RHT Refrigerant Connections Sweat (In.) [mm] ID Liquid Vapor Unit Height H In. [mm] Unit Width W In. [mm] Supply Duct A In. [mm] Unit Weight/Shipping Weight (Lbs.) [kg] Unit With Coil (Max. KW) 17S /8 [9.] / [19.0] 1 / [1080] 17 1 / [.] 16 1 / [06.] 9/106 [/8] 1M /8 [9.] / [19.0] 1 / [1080] 1 1 / [.] 19 1 / [9.] 111/16 [0/7] 617S /8 [9.] / [19.0] 1 / [1080] 17 1 / [.] 16 1 / [06.] 96/110 [/0] 61M /8 [9.] / [19.0] 0 1 / [18] 1 1 / [.] 19 1 / [9.] 19/1 [9/66] 81M /8 [9.] 7/8 [.] 7 1 / [18] 1 1 / [.] 19 1 / [9.] 11/1 [6/69] 601S /8 [9.] 7/8 [.] 7 1 / [18] 1 1 / [.] 19 1 / [9.] 11/1 [6/69] 60M /8 [9.] 7/8 [.] 1 / [110] 1 / [6.] 1 / [8.0] 161/178 [7/81] *Maximum dehumidification airflow.
6 Dimensional Data Unit Dimensions FIGURE 6 VERTICAL DOWNFLOW & HORIZONTAL RIGHT APPLICATION RAILS DETAIL A ENSURE THE RETAINING CHANNEL IS FULLY ENGAGED WITH THE COIL RAIL FIGURE 7 INDOOR COIL AND DRAIN PAN SET-UP STRAPS TOP AIR STOP HORIZONTAL ADAPTER KIT PRESSURE TRANSDUCER VAPOR LINE CONNECTION AUXILIARY HORIZONTAL DRAIN CONNECTION PRIMARY DRAIN CONNECTION AUXILIARY UPFLOW/DOWNFLOW DRAIN CONNECTION LIQUID LINE CONNECTION ELECTRONIC EXPANSION VALVE (EEV) VERTICAL DRAIN PAN ELECTRONIC EXPANSION VALVE CONTROL 1 /16 [11 mm] 1 /8 [10 mm] 1 /16 [76 mm] 1 /16 [8 mm] 11 /8 [9 mm] 1 1 /16 [7 mm] 1 /8 [ mm] 1 /16 [71 mm] 1 / [1 mm] /8 [16 mm] 6
7 Airflow Directional Data Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW 7
8 Airflow Performance Data Airflow Performance Airflow performance data is based on cooling performance with a coil and no filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the. [8 mm] to.7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of.1 inch [ mm] W.C. external static range. Airflow Operating Limits Model Cabinet Width 17/1 17/1 Cooling BTUH x 1,000 Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (7. CFM [18 L/s]/1,000 BTUH) (0 CFM [1 L/s]/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (. CFM [16 L/s]/1,000 BTUH) (00 CFM [189 L/s]/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (0.0 CFM [1 L/s]/1,00 BTUH) (60 CFM [170 L/s]/Ton Nominal) Maximum kw Electric Heating & Minimum Electric Heat CFM [L/s] [] 800 [78] 70 [0] [91] [67] 100 [66] 1080 [10] [97] Maximum Electric Heat Rise F [ C] 6 [17.] 1 [10.6] 1-8/ [80] 1600 [7] 10 [680] 10 [709] 0 [10] [911] 1800 [80] 160 [76] [786] [1.] 8
9 Airflow Performance Data 08V/0V Airflow Performance Data RHT (Constant Torque (ECM) ) Air Handler (-)HT 17SE 17SE with 1kW Heater 17SE 17SE with 1kW Heater 1ME 1ME with 1kW 1ME Outdoor Unit (-)P17 (-)P17 (-)P17 (-)P17 (-)A17 Speed From Factory (-)A17 (-)A17 Blower Size HP Size # Speeds 1/ 10x8 1/ 10x8 1/ 10x8 1/ 10x8 1/ 10x8 1/ 10x8 1/ 10x8 Speed CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 87 [9] 71 [6] 608 [87] [61] 8 [9] [] 61 [90] 7 [70] [8] 69 [7] 89 [78] [] 67 [0] [81] 69 [97] 8 [76] [6] 86 [99] 788 [7] 7 [0] 679 [0] [0] 816 [8] 770 [6] [16] 87 [90] 769 [6] 7 [1] 661 [1] [17] 791 [7] 76 [] [76] 6 [99] 7 [168] [10] 91 [79] [6] 7 [] 9 [0] [] 09 [0] 177 [8] [9] 6 [67] 6 [8] 0 [8] 0 [7] [9] 67 [18] [00] [71] 79 [] 699 [0] 67 [0] 607 [86]
10 Airflow Performance Data 08V/0V Airflow Performance Data RHT (Constant Torque (ECM) ) Air Handler (-)HT 1ME with 1kW 617SE 617SE with 1kW Heater 617SE 617SE with 1kW Heater 61ME 61ME with 1kW Heater Outdoor Unit Speed From Factory (-)A17 (-)P176 (-)P176 (-)P176 (-)P176 (-)A176 (-)A176 Blower Size HP Size # Speeds 1/ 10x8 1/ 10x8 1/ 10x8 1/ 10x8 1/ 10x8 / 10x10 / 10x10 Speed CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 767 [6] 9 [6] 6 [1] [6] 76 [] 670 [16] 60 [8] [6] [16] 100 [96] 1017 [80] 997 [71] 9 [1] [1] 100 [91] 1001 [7] [0] 10 [8] 99 [68] 9 [9] 910 [9] [00] 101 [79] 976 [61] [99] 17 [8] 1199 [66] 116 [0] 110 [] [60] 1 [87] 111 [7] [88] 11 [7] 117 [] 110 [8] 110 [] [90] 119 [7] 1186 [60] [8] 8 [0] 776 [66] 69 [11] 99 [8] [17] 10 [9] 96 [] 909 [9] 80 [87] [91] 801 [78] 78 [9] 6 [0] 1 [] [06] 1007 [7] 91 [] 797 [76] 6 [08]
11 Airflow Performance Data 08V/0V Airflow Performance Data RHT (Constant Torque (ECM) ) Air Handler (-)HT 61ME 61ME with 1kW Heater 81ME 81ME with 1kW Heater 81ME 81ME with 1kW Heater Outdoor Unit (-)A176 (-)A176 (-)P1760 (-)A178 (-)P1760 (-)A178 (-)P1760 (-)A178 (-)P1760 (-)A178 Speed From Factory Blower Size HP Size # Speeds / 10x10 / 10x10 1/ 10x10 1/ 10x10 1/ 10x10 1/ 10x10 Speed 1 1 CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 10 [97] 1001 [7] 99 [] 87 [1] [616] 160 [9] 11 [7] 117 [1] 1107 [] [8] 971 [8] 907 [8] 8 [9] [606] 17 [8] 1189 [61] 119 [7] 1087 [1] [08] 7 [7] 68 [06] 97 [8] 8 [] 97 [] [0] [1] 10 [9] 99 [70] 99 [8] [660] 161 [6] 11 [6] 186 [607] 1 [86] [77] 69 [8] 61 [90] 61 [6] [] 0 [0] [61] [07] 1019 [81] 971 [8] 90 [9] [61] 11 [6] 100 [61] 17 [9] 11 [7] [69] 1160 [7] 111 [9] 1080 [10] [78] 166 [767] 180 [76] 19 [706] 1 [6] [8] 110 [8] 1100 [19] 106 [01] [777] 160 [77] 1 [7] 19 [70] 16 [67]
12 Airflow Performance Data 08V/0V Airflow Performance Data RHT (Constant Torque (ECM) ) Air Handler (-)HT 60ME 60ME with 1kW Heater 60ME 60ME with 1kW Heater Outdoor Unit (-)A17 (-)A17 (-)A17 (-)A17 Speed From Factory Blower Size HP Size # Speeds 1/ 11x11 1/ 11x11 1/ 11x11 1/ 11x11 Speed CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] 171 [67] 10 [61] 18 [89] 118 [8] [77] 11 [71] 160 [689] 106 [66] 1 [6] [6] 176 [60] 11 [7] 11 [] [68] 11 [60] 1 [8] 11 [] 1071 [06] [69] 116 [61] 17 [9] 1190 [6] [8] 1709 [807] 169 [778] 161 [761] 160 [76] [6] 187 [607] 1 [78] 116 [6] [816] 168 [79] 1610 [760] 11 [71] 19 [68]
13 Airflow Performance Data 08V/0V Airflow Performance Data RHT (Constant Torque (ECM) ) Air Handler (-)HT 1MT 61MT Outdoor Unit (-)A17 (-)A176 Speed From Factory Size HP Blower Size / 10 x 10 / 10 x 10 # Speed Speeds 1 1 CFM [L/s] Air Delivery/RPM/Watts (Dry Coil No Filter) 08-0 VAC 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM [L/s] 899 [] 6 [99] 6 [1] 197 [9] 18 [6] RPM Watts CFM [L/s] 88 [17] 69 [97] 70 [69] 99 [] 7 [06] 69 [17] 07 [1] RPM Watts CFM [L/s] 897 [] 88 [91] 781 [69] 70 [9] 67 [18] 61 [9] 6 [66] RPM Watts CFM [L/s] TBD TBD TBD TBD TBD TBD TBD RPM TBD TBD TBD TBD TBD TBD TBD Watts TBD TBD TBD TBD TBD TBD TBD CFM [L/s] 99 [69] 9 [0] 899 [] 8 [0] 807 [81] 7 [6] 70 [] RPM Watts CFM [L/s] 1000 [7] 96 [7] 87 [99] 77 [66] 719 [9] 66 [0] 7 [70] RPM Watts CFM [L/s] 906 [8] 66 [09] 99 [8] 17 [] 7 [06] 6 [171] 08 [1] RPM Watts CFM [L/s] 1178 [6] 1100 [] 107 [99] 999 [71] 911 [0] 86 [07] 816 [8] RPM Watts CFM [L/s] 100 [96] 991 [68] 9 [7] 87 [90] 779 [68] 71 [7] 60 [0] RPM Watts CFM [L/s] 178 [60] 16 [66] 170 [99] 11 [7] 1160 [7] 108 [99] 106 [89] RPM Watts
14 Airflow Performance Data 08V/0V Airflow Performance Data RHT (Constant Torque (ECM) ) Air Handler (-)HT 81MT 60MT Outdoor Unit (-)A178 (-)A1760 Speed From Factory Size HP Blower Size / 10 x 10 / 10 x 10 # Speed Speeds 1 1 CFM [L/s] Air Delivery/RPM/Watts (Dry Coil No Filter) 08-0 VAC 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM [L/s] 91 [1] 8 [97] 7 [] 666 [1] 601 [8] [6] 6 [1] RPM Watts CFM [L/s] 1180 [7] 116 [1] 1067 [0] 9 [1] 909 [9] 86 [0] 796 [76] RPM Watts CFM [L/s] 189 [70] 18 [70] 106 [711] 167 [69] 106 [66] 18 [61] 1 [8] RPM Watts CFM [L/s] 18 [60] 1 [8] 118 [8] 110 [] 99 [69] 976 [60] 9 [] RPM Watts CFM [L/s] 169 [78] 16 [767] 18 [78] 1 [79] 101 [708] 10 [688] 1 [67] RPM Watts CFM [L/s] 17 [68] 108 [617] 16 [88] 118 [8] 11 [0] 10 [97] 99 [69] RPM Watts CFM [L/s] 19 [66] 188 [608] 10 [76] 1161 [8] 1089 [1] 109 [86] 96 [] RPM Watts CFM [L/s] 179 [8] 1699 [80] 167 [777] 160 [76] 11 [7] 106 [711] 1 [68] RPM Watts CFM [L/s] 19 [68] 188 [6] 19 [67] 166 [97] 10 [67] 11 [] 1078 [09] RPM Watts CFM [L/s] 1888 [891] 180 [87] 180 [8] 171 [86] 1711 [807] 1666 [786] 16 [766] RPM Watts Notes: Constant Torque motor speed changes. All Constant Torque motors have speed tabs. Speed tab 1 is for continuous fan. Speed tab (low static) and Speed tab (high static) are for lower tonnage. Speed tab (low static) and Speed tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at Speed tab, except for -8, which is set at Speed tab. For instance, (-)H1T-HM17JA is always shipped at high static -ton airflow (Speed tab ). To change to 1.-ton airflow, move the blue wire to Speed tab or on the Constant Torque motor. The low static Speed tab (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static Speed tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate Speed tab as required by the application needs. The airflow for continuous fan (Speed tab 1) is always set at 0% of the Speed tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 1
15 Electrical Data Electrical Data Blower Only No Electric Heat RHT Model RHT Voltage Phase* Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Overcurrent Protector 17S 1 1/ M 1 1/ S 1 1/ M 08/ / M 1 / S 1 / M 1 / * Blower motors are all single phase motors. 1
16 Electrical Data Electrical Data With Electric Heat RHT Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RHT 17S 1M 617S Heater Model No. Heater kw (08/0V) (80V) PH/HZ No. Elements kw Per Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection RXBH-17?0J./.0 1/ SINGLE 10.8/ /18 0/0 RXBH-17?0./.0 1/ SINGLE 10.8/ /18 0/0 RXBH-17?0J.6/.8 1/ SINGLE 17./ /7 /0 RXBH-17?07J./7. 1/ SINGLE 6.0/ /0 /0 RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 9./1. 1/ SINGLE.1/ /68 60/70 RXBH-17A1J.1/. 1/ MULTIPLE CKT 1 1.0/ / / 6./8. 1/ MULTIPLE CKT 0.1/.7 0 8/ 0/ RXBH-17A07C./7. /60 -. SINGLE 1.0/ / / RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/ /1 0/ RXBH-17A1C 9./1. / SINGLE 6.1/ /0 /0 RXBH-17?0J./.0 1/ SINGLE 10.8/ /0 0/0 RXBH-17?0./.0 1/ SINGLE 10.8/ /0 0/0 RXBH-17?0J.6/.8 1/ SINGLE 17./ /9 0/0 RXBH-17?07J./7. 1/ SINGLE 6.0/ /1 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17A1J RXBH-17A1J 9./1. 1/ SINGLE.1/ /69 60/70.1/. 1/ MULTIPLE CKT 1 1.0/17..8 /6 /0 6./8. 1/ MULTIPLE CKT 0.1/.7 0 8/ 0/ 10.8/1. 1/ SINGLE 1.9/ /79 70/80.6/.8 1/ MULTIPLE CKT 1 17./ /9 0/0 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 1.8/17.0 1/ SINGLE 61.6/ /9 90/100 RXBH-17A18J./.7 1/ MULTIPLE CKT 1 0./.6.8 0/ 0/ 8./11. 1/ MULTIPLE CKT 1.1/7. 0 /9 60/60 RXBH-17A07C./7. /60 -. SINGLE 1.0/17..8 /6 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.8 9/ 0/ RXBH-17A1C 9./1. / SINGLE 6.1/ / 0/ RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.8 1/7 /0 RXBH-17A18C 1.8/17.0 / SINGLE./ / 0/60 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. Heater loads are balanced on phase heater kits with or 6 heating elements only. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (0V) single phase air handler is designed to be used with single or three phase 0 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A1 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 0% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out 16
17 Electrical Data Electrical Data With Electric Heat RHT (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RHT 61M 81M Heater Model No. Heater kw (08/0V) (80V) PH/HZ No. Elements kw Per Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection RXBH-17?0J./.0 1/ SINGLE 10.8/ /1 0/ RXBH-17?0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-17?07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17A1J 10.8/1. 1/ SINGLE 1.9/ /80 70/80.6/.8 1/ MULTIPLE CKT 1 17./ /0 0/0 7./9.6 1/ MULTIPLE CKT.6/ /0 /0 1.8/17.0 1/ SINGLE 61.6/ /9 90/100 RXBH-17A18J./.7 1/ MULTIPLE CKT 1.0 1/ / 8./11. 1/ MULTIPLE CKT 0.0 /9 60/60 RXBH-17A07C./7. /60 -. SINGLE 1.0/17..0 /7 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.0 0/ 0/ RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.0 /9 /0 RXBH-17A18C 1.8/17.0 / SINGLE.6/ /7 0/60 RXBH-17B0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-17B07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17B10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17?0J.6/.8 1/ SINGLE 17./ /0 0/0 RXBH-17?07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ / 0/60 RXBH-17A1J RXBH-17A18J RXBH-A0J 10.8/1. 1/ SINGLE 1.9/ /80 70/80.6/.8 1/ MULTIPLE CKT 1 17./ /0 0/0 7./9.6 1/ MULTIPLE CKT.6/ /0 /0 1.8/17.0 1/ SINGLE 61.6/ /9 90/100./.7 1/ MULTIPLE CKT 1 0./.6.0 1/ 0/ 8./11. 1/ MULTIPLE CKT 1.1/ /9 60/60 1./19. 1/60-8 SINGLE 69./80.0 9/10 100/110 7./9.6 1/ MULTIPLE CKT 1.6/ / 0/60 7./9.6 1/ MULTIPLE CKT.6/ /0 /0 18.0/.0 1/ SINGLE 86./ /10 1/10 RXBH-AJ 6.0/8.0 1/ MULTIPLE CKT 1 8.8/..0 1/7 /0 6.0/8.0 1/ MULTIPLE CKT 8.8/ / 0/ 6.0/8.0 1/ MULTIPLE CKT 8.8/ / 0/ RXBH-17A07C./7. /60 -. SINGLE 1.0/17..0 /7 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.0 0/ 0/ RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.0 /9 /0 RXBH-17A18C 1.8/17.0 / SINGLE.6/ /7 0/60 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. Heater loads are balanced on phase heater kits with or 6 heating elements only. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (0V) single phase air handler is designed to be used with single or three phase 0 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A1 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 0% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out 17
18 Electrical Data Electrical Data With Electric Heat RHT (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RHT 81M 601S 60M Heater Model No. RXBH-A0C* RXBH-AC* Heater kw (08/0V) (80V) PH/HZ No. Elements kw Per Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Ampacity Minimum Circuit Ampacity Maximum Overcurrent Protection 1./19. /60 -. SINGLE 0.0/6..0 /6 60/70 7./9.6 /60 -. MULTIPLE CKT 1 0.0/.1.0 0/ 0/ 7./9.6 /60 -. MULTIPLE CKT 0.0/ /9 /0 18.0/.0 / SINGLE 0.0/ /77 70/80 9.0/1.0 / MULTIPLE CKT 1.0/ / 0/ 9.0/1.0 / MULTIPLE CKT.0/ /7 /0 RXBH-17?0J.6/.8 1/ SINGLE 17./ /1 0/ RXBH-17?07J./7. 1/ SINGLE 6.0/ / 0/ RXBH-17?10J 7./9.6 1/ SINGLE.6/ /6 0/60 RXBH-17A1J RXBH-17A18J RXBH-A0J RXBH-AJ 10.8/1. 1/ SINGLE 1.9/ /81 80/90.6/.8 1/ MULTIPLE CKT 1 17./ /1 0/ 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 1.8/17 1/ SINGLE 61.6/ /9 90/100./.7 1/ MULTIPLE CKT 1 0./.6.6 1/ 1/./.7 1/ MULTIPLE CKT 1.1/7. 0 /9 60/60 1./19. 1/ SINGLE 69./80.6 9/ /110 7./9.6 1/ MULTIPLE CKT 1.6/ /6 0/60 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 18.0/.0 1/ SINGLE 86./ /11 1/10 6.0/8.0 1/ MULTIPLE CKT 1 8.8/..6 /8 /0 6.0/8.0 1/ MULTIPLE CKT 8.8/. 0 6/ 0/ 6.0/8.0 1/ MULTIPLE CKT 8.8/. 0 6/ 0/ 1.6/8.8 1/ SINGLE 10.8/ /16 10/17 RXBH-A0J 7./9.6 1/ MULTIPLE CKT 1.6/ /6 0/60 (60S only) (1800 CFM only) 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 7./9.6 1/ MULTIPLE CKT.6/0.0 0 /0 /0 RXBH-17A07C./7. /60 -. SINGLE 1.0/17..6 /8 /0 RXBH-17A10C 7./9.6 /60 -. SINGLE 0.0/.1.6 1/ / RXBH-17A1C 10.8/1. / SINGLE 0.0/.6.6 /9 /0 RXBH-17A18C 1.8/17.0 / SINGLE.6/ /7 0/60 RXBH-A0C* RXBH-AC* RXBH-A0C* (1800 CFM only) RXBH-A0C (60S only) (1800 CFM only) 1./19. /60 -. SINGLE 0.0/6..6 6/6 60/70 7./9.6 /60 -. MULTIPLE CKT 1 0.0/.1.6 1/ / 7./9.6 /60 -. MULTIPLE CKT 0.0/.1 0 /9 /0 18.0/.0 / SINGLE 0.0/ /78 70/80 9.0/1.0 / MULTIPLE CKT 1.0/ / 0/ 9.0/1.0 / MULTIPLE CKT.0/8.9 0 /7 /0 1.6/8.8 / SINGLE 60.0/ /9 90/ /1. / MULTIPLE CKT 1 0.0/.7.6 /0 /0 10.8/1. / MULTIPLE CKT 0.0/.7 0 8/ 0/ NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x.1 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (0V) single phase air handler is designed to be used with single or three phase 0 volt electric heaters. In the case of connecting -phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A1 and RXBJ-A1 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 0% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out 18
19 Electrical Wiring Electrical Wiring Power Wiring Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. Supply wiring must be 7 C minimum copper conductors only. See electrical data for product Ampacity rating and Circuit Protector requirement. Accessories Combustible Floor Base RXHB- Model Cabinet Size 17 1 Nominal Cooling Capacity-Tons Combustible Floor Base Model Number RXHB-17 RXHB-1 RXHB- Jumper Bar Kit Ckt. to 1 Ckt. RXBJ-A1 is used to convert single phase multiple three circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Jumper Bar Kit Ckt. to 1 Ckt. RXBJ-A1 is used to convert single phase multiple two circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Note: No jumper bar kit is available to convert three phase multiple two circuit units to a single supply circuit. Auxiliary Horizontal Overflow Pan Accessory RXBM- Auxiliary Horizontal Overflow Pan Accessory Model Number - RXBM-AC8 - RXBM-AC61 Supply and Return Air Sensor Kit RXHT-A0 The RXHT-A0 Thermistor Kit is to be used with the air handler control to monitor the system return and leaving air temperatures. These temperatures can be monitored with the EccoNet communicating thermostat. Grounding This product must be sufficiently grounded in accordance with National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. A grounding lug is provided. Auxiliary Electric Heater Kits RXBH- Heater Kits include circuit breakers which meet UL and cul requirements for service disconnect. See the Electric Heat Electrical Data in this specification sheet for specific Heater Kit Model numbers. External Filter Base RXHF- Model Cabinet Size Coil Model Model Cabinet Size Filter Size In. [mm] 1 0 x 0 [08 x 08] Horizontal Adapter Kit Model Number (Single Qty.) Filter Size In. [mm] x 0 [06 x 08] 1 0 x 0 [08 x 08] Part Number* RXHF-1 x 0 [6 x 08] RXHF-.70 *Accommodates 1" or " filter Horizontal Adapter Kit Model Number (10-Pack Qty.) 1 17 RXHH-A01 RXHH-A0 RXHH-A01 x 10 RXHH-A0 x 10 1/617/61 RXHH-A0 RXHH-A0 x 10 81/8/601 RXHH-A06 RXHH-A06 x RXHH-A0 RXHH-A0 x 10 Part Number* RXHF-17 RXHF x 0 [6 x 08] RXHF-.70 *Accommodates 1" or " filter A A B 1.0. Horizontal Adapter Kit RXHH- This horizontal adapter kit is used to convert Upflow/Downflow only models to horizontal flow. See the following table to order proper horizontal adapter kit. External Filter Base RXHF- B RXHF- 19
20 Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required)...Ten (10) Years *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 0
21 Notes 1
22 Notes
23 Notes
24 The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box Fort Smith, Arkansas Rheem Canada Ltd./Ltée 1 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P PRINTED IN U.S.A /18 QG FORM NO. H11-6 REV.
Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler
Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows
More informationHIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER
FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart
More informationRheem High Efficiency Modulating EcoNet Enabled Air Handler
Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows
More informationRuud Standard Efficiency Air Handler
Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationRheem Air Handlers. RHML- Series X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the
More informationRuud Standard Efficiency Air Handler
Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationRheem Standard Efficiency Air Handler
Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the
More informationWH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3
FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides
More informationRheem High Efficiency Modulating EcoNet Enabled Air Handler
Air Handlers Rheem High Efficiency Modulating EcoNet Enabled Air Handler RHMV- Series Constant CFM Motor (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The RHMV Air Handler is part
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22
More informationRheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationRuud High Efficiency Air Handler
Air Handlers Ruud High Efficiency Air Handler RBHP- Series X-13 (ECM) Motor Efficiencies up to 16 SEER Industry Standard R-410A Refrigerant also Suitable for R-22 Applications Models featuring Electric
More informationAIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant
FORM NO. H11-527 REV. 5 Supersedes Form No. H11-527 Rev. 4 AIR HANDLERS (Model with Coil) AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant earth friendly
More informationRuud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationRheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump
More informationAIR HANDLERS AIR HANDLERS
FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard
More informationAIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-509 REV. 8 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING R-22 REFRIGERANT: (-)HLA Efficiency (-)HSA Standard Efficiency FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HLL Efficiency (-)HSL Standard Efficiency
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HKL Premium Efficiency efrigerant WARNING! These instructions are intended as an aid to qualified licensed service
More informationAmeristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:
Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR
More informationRheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RW1P/RW1T- Series Nominal Heating Capacities: 40-100 kbtu [11.7-29.3 kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent
More informationRheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace
Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace R802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: efrigerant (-)HPL Premium 16 SEER Efficiency! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HPL Premium 16 SEER Efficiency efrigerant! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!!
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationRheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces
Gas Furnaces Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces R98V- Series 98% A.F.U.E. Input Rates from 60 to 115 kbtu [11.57 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)
More informationRHEEM Split Systems Condensers All submitted condensers meet the 15 SEER minimum All submitted condensers meet the 208/230V specification All submitted condensers contain enhanced mufflers to help dissipate
More informationRheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] All Models except R96VA085
More informationTECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES
TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified
More informationRheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel
More informationRheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] All Models except R96VA085
More informationRheem Classic Series Downflow/ Horizontal Gas Furnaces
Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationRheem Classic Series Multi-position Gas Furnaces
Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationRheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] All Models except R96VA085
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationRheem Classic Plus Series Two Stage Multi position Gas Furnaces
Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed
More informationRheem Classic Plus Series Multi position Gas Furnaces
Gas Furnaces Rheem Classic Plus Series Multi position Gas Furnaces R95T- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationRuud Achiever Plus Series Multi-position Gas Furnaces
Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationWAHL A Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,
More informationFEM4X. Product Specifications FAN COILS /14/15
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator
More informationSeries Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.
Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationMERIT SERIES Up Flow / Horizontal
A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional
More informationREM4P, REM4X. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with
More informationTECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)
TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology ECM Motor Nominal Heating Capacities: 40-100 kbtu [11.7-29. kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent and RTG-64XL
More informationRheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu
THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationTECHNICAL SPECIFICATIONS B6VMMX
TECHNICAL SPECIFICATIONS BVMM Series Air Handler with TV, -, Btuh (Heat Pump & Air Conditioner) R-4A Refrigerant The BVMM Series of air handlers, when combined with our heat pump or air conditioner, offers
More information157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device
More information49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3
More informationFAN UNIT FH4A Sizes 001 thru 004
FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging
More informationRheem Prestige Series Variable Speed Heat Pumps
Seasonal Energy Efficiency Ratio - SEER THIS MODEL 10.0 USES LESS ENERGY 17.00 17.0 Air Heat Pumps Rheem Prestige Series Variable Speed Heat Pumps Efficiencies up to 20 SEER/14 EER/11.5 HSPF Nominal Sizes
More informationRooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type
More informationCWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH
CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal
More informationIMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2
Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationRheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System
Gas Furnaces Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2 System RGJF- Series Up to 94.8% A.F.U.E. Input Rates from 60 to 120 kbtu [17.58 to 35.16 kw] With
More informationRuud Acheiver Series Upflow Gas Furnaces
Gas Furnaces Ruud Acheiver Series Upflow Gas Furnaces RGRC- Series 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationTECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product
More informationFF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D
FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationRheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor
THIS MODEL 78% 82% 88% 92.0% 97% Air Oil Furnaces Rheem Classic Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor ROCA-***P: Highboy Series ROLA-***P: Lowboy Series Input Ratio from 84,000
More informationProduct Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More information49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)
ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat
More informationDimensions H x W x D in. (mm)
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,
More informationINSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES
INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................
More informationFXM4X. Product Specifications FAN COILS FXM4X
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More informationRheem Prestige Series Variable Speed Air Conditioners
Seasonal Energy Efficiency Ratio - SEER THIS MODEL 10.0 USES LESS ENERGY 17.00 17.0 Air Air Conditioners Rheem Prestige Series Variable Speed Air Conditioners Efficiencies up to 20 SEER/13 EER Nominal
More informationTECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationHydronic Air Handler Powered by Tankless Technology
Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RHWB- Series Nominal Heating Capacities: 32-90 kbtu [9.38-26.39 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in
More informationRheem Prestige Series Variable Speed Heat Pumps
Seasonal Energy Efficiency Ratio - SEER THIS MODEL 10.0 USES LESS ENERGY 17.00 17.0 Air Heat Pumps Rheem Prestige Series Variable Speed Heat Pumps Efficiencies up to 20 SEER/14.5 EER/13 HSPF Nominal Sizes
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationDAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed
PRODUCT SPECIFICATIONS AIR HANDLERS CBA8MV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 080 August 08 Supersedes March 08 Nominal Capacity -. to Tons Optional
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More informationCBX32MV (HFC-410A) SERIES UNITS
Service Literature Corp. 005-L2 Revised November 5, 202 (HFC-40A) SERIES UNITS (icomfort-enabled) NOTICE A thermostat is not included and must be ordered separately. The Lennox icomfort thermostat must
More informationModular Multi-position Air Handlers
Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationModel Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)
FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS (-)BHK ELECTRIC FURNACE ELECTRIC HEAT WITH OR WITHOUT INDOOR COOLING COIL (-)BHK FAN COIL UNIT WITH OR WITHOUT ELECTRIC HEAT WITH OR WITH OR WITHOUT INDOOR COOLING COIL (-)BHK
More informationACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons
ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum
More informationProduct Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006
Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air
More informationTECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are
More informationCFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH
CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationCFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH
CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More information