700A11. Geothermal Heat Pump 3-5 ton (variable speed) Submittal Data English Language/IP Units SD2700AN 12/17
|
|
- Sandra Reed
- 5 years ago
- Views:
Transcription
1 700A eothermal Heat Pump -5 ton (variable speed) Submittal Data English Language/IP Units SD700AN /7
2 ontractor: 7 Series 700A Model Nomenclature N V V 06 * 0 L 0 J 6 N Model N 7 series Water-to-Air to-a ompressor sor ype V Variable able Speed abinet onfiguration V Vertical H Horizontal Unit apacityacity MBU s 06,08,060,060 Vintage * Factory Use Only Voltage 08-0/60/ Hot Water Options 0 No Hot Water Hot Water eneration with Factory Installed Pump Blower Motor Options Variable Speed EM Blower High Static Variable Speed EM (06 Only) Future Option N - None ontrols Option J Aurora Variable Speed ontrol K Aurora VS ontrol w/ Performance Monitoring L Aurora Variable Speed ontrol with UP M Aurora VS ontrol w/ Performance Monitoring and UP Filter Options 0 inch MEV Filter AlpinePure (Vertical Only) eturn Air onfiguration L Left ight Discharge onfiguration op (Vertical) B Bottom (Vertical) ear (Vertical) S Side (Horizontal) E End (Horizontal) Water oax opper N upronickel Notes: UP is not compatible with Symphony or IntelliZone ev.: 0//07 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
3 ontractor: 7 Series 700A AHI/ISO 56- Performance atings Variable Speed EM Motor AHI/ASHAE/ISO 56- English (IP) Units Model apacity Modulation Airflow lg/htg cfm Water Loop Heat Pump round Water Heat Pump round Loop Heat Pump ooling EW 86 F apacity Btu/h EE Btu/h per W Heating EW 68 F apacity Btu/h OP ooling EW 59 F apacity Btu/h EE Btu/h per W Heating EW 50 F apacity Btu/h OP ooling Full Load 77 F Part Load 68 F apacity Btu/h EE Btu/h per W Heating Full Load F Part Load F apacity Btu/h Full, , ,000.5, ,000.0, /500 Part, , ,000 7., , , Full, , , ,000. 6,000.7, /800 Part 6,000.5, , , , , Full 50, , , , , , /00 Part 0, , ,00 5.8, , , ooling capacities based upon 80.6 F DB, 66. F WB entering air temperature 6/5/ Heating capacities based upon 68 F DB, 59 F WB entering air temperature All ratings based upon 08V operation OP Energy Star ompliance able ier Model round Water round Loop 06 Yes Yes 08 Yes Yes 060 Yes Yes 6// Energy Star ating riteria In order for water-source heat pumps to be Energy Star rated they must meet or exceed the minimum efficiency requirements listed below. ier represents the current minimum efficiency water source heat pumps must have in order to be Energy Start rated. ier : //0 No Effective End Date Published Water-to-Air EE OP round Loop 7..6 round Water.. Water-to-Water round Loop 6.. round Water 0..5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
4 ontractor: 7 Series 700A Vertical Dimensional Data op Air Discharge Q LEF EUN P IH EUN O Q L O M L N N OP OP.9in [.8cm].9in [.8cm] S S I K J A FON DEHF ft [6 cm] Primary Service Access B LEF SIDE B IH SIDE Vertical op Flow Model Overall abinet A Width B Depth Height D Loop In E Loop Out Water onnections F HW In HW Out H ondensate Loop Water FP HW Sweat (I.D.) I / in. cond Low Voltage Electrical onnections J / in. cond K / in. cond L M Ext Power Pump Supply Discharge onnection duct flange installed (±0.0 in) N O Supply Supply Width Depth P eturn onnection using std deluxe filter rack (±0.0 in) Q S eturn eturn Depth Height in in. / in cm Swivel Female in in. / in cm Swivel Female in in. / in cm Swivel Female ondensate is / in. PV female glue socket and is switchable from side to front 6/9/ Unit shipped with deluxe in. (field adjustable to in.) duct collar/filter rack extending from unit.5 in. and is suitable for duct connection. Discharge flange is field installed and extends in. [5.mm] from cabinet Decorative molding and/or water connections extend. in. [0.5mm] beyond front of cabinet. Louvered vents in the compressor section right side access panel extend / in. [.7 mm] from side of cabinet. Allow clearance for venting. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
5 ontractor: 7 Series 700A Vertical Dimensional Data cont. Bottom Air Discharge LEF EUN IH EUN.70 (. cm) S S I K J D E F B LEF SIDE Q B IH SIDE Q.90 (.7 cm) A 5 H L FON ft [6 cm] Primary Service Access O N L O M N P LEF BOOM DISHAE FLOO FOO PIN IH BOOM DISHAE FLOO FOO PIN Bottomflow Models Overall abinet A Width B Depth Height Water onnections 5 D In E Out F HW In HW Out Loop Water FP HW Sweat (I.D.) Electrical Knockouts I / in. cond Low Voltage J / in. cond Ext Pump K / in. cond Power Supply Discharge onnection duct flange installed (±0.0 in) L M N O Supply Supply Width Depth P eturn onnection using std deluxe filter rack (±0.0 in) Q S eturn eturn Depth Height H ondensate 06- in in. / in cm Swivel Female ondensate is / in. PV female glue socket and is switchable from side to front /0/ Unit shipped with deluxe in. (field adjustable to in.) duct collar/filter rack extending from unit.5 in. and is suitable for duct connection. Water connections extend. in. [0.5mm] beyond front of cabinet. Louvered vents in the compressor section right side access panel extend / in. [.7 mm] from side of cabinet. Allow clearance for venting. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 5 Page of
6 ontractor: 7 Series 700A Vertical Dimensional Data cont. ear Air Discharge.90 in. [.8 cm].90 in. [.8 cm] I K J E H F ft [6 cm] Primary Service Access A FON D O Q Q P M M L S S N N A B B A EA VIEW LEF EUN SIDE VIEW LEF EUN SIDE VIEW IH EUN EA VIEW IH EUN Vertical ear Discharge Model Overall abinet A Width B Depth Height D Loop In E Loop Out Water onnections F HW In HW Out H ondensate Loop Water FP HW Sweat (I.D.) I / in. cond Low Voltage Electrical onnections J / in. cond Ext Pump K / in. cond Power Supply Discharge onnection duct flange installed (±0.0 in) L Supply Width M Supply Depth N O P Q eturn onnection using std deluxe filter rack (±0.0 in) S eturn eturn Depth Height 06 in in. / in cm Swivel Female in in. / in cm Swivel Female in in. / in cm Swivel Female ondensate is / in. PV female glue socket and is switchable from side to front 6/9/ Unit shipped with deluxe in. (field adjustable to in.) duct collar/filter rack extending from unit.5 in. and is suitable for duct connection. Discharge flange is field installed and extends in. [5.mm] from cabinet Decorative molding and/or water connections extend. in. [0.5mm] beyond front of cabinet. Louvered vents in the compressor section right side access panel extend / in. [.7 mm] from side of cabinet. Allow clearance for venting. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 6 Page of
7 ontractor: 7 Series 700A Horizontal Dimensional Data OP VIEW Q P.in [5.cm] MOUN () HANE BAKES AS SHOWN O ALLOW AESS O FILE ft [6 cm] Primary Service Access.9in [.8cm] FON VIEW A S SIDE DISHAE VIEW B N O L L END VIEW O S M I K J D E F H AS SHOWN L UNI ( UNI ON OPPOSIE SIDE SAME DIMENSIONS) Horizontal Models Overall abinet Water onnections Electrical onnections I / in. cond J / in. cond K / in. cond Discharge onnection duct flange installed (±0.0 in) eturn onnection using std deluxe filter rack (±0.0 in) F H Loop HW M N Q A B D E Low Ext Power HW HW ond- Water Sweat L Supply Supply O P eturn eturn S Width Depth Height In Out Voltage Pump Supply In Out ensate FP (I.D.) Height Depth Depth Height 06 in in. / in SEE.6. SEE cm Swivel Female HA.5.5 HA in in. / in SEE.6. SEE cm Swivel Female HA.5.5 HA in in. / in SEE.6. SEE cm Swivel Female HA.5.5 HA ondensate is / in. PV female glue socket and is switchable from side to front Unit shipped with deluxe in. (field adjustable to in.) duct collar/filter rack extending from unit.5 in. and is suitable for duct connection. Discharge flange is field installed and extends in. [5.mm] from cabinet Decorative molding and/or water connections extend. in. [0.5mm] beyond front of cabinet. Louvered vents in the compressor section right side access panel extend / in. [.7 mm] from side of cabinet. Allow clearance for venting. 6/9/ Units Not Shown Above L O ight eturn End Discharge in.8.6 cm 7..8 ight eturn Side Discharge in cm. 7.5 Left eturn End Discharge in cm. 9. Left eturn Side Discharge in cm WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 7 Page of
8 ontractor: 7 Series 700A Physical Data Variable Speed Model ompressor ( each) Variable Speed Scroll Factory harge -0A, oz [kg] Vertical 95 [.69] 0 [.0] 0 [.96] Factory harge -0A, oz [kg] Horizontal 95 [.69] 6 [.85] 8 [.9] EM Blower Motor & Blower Blower Motor ype/speeds EM Variable Speed Blower Motor- hp [W] EM / [7] [76] [76] High Static Blower Motor - hp [W] EM [76] n/a n/a Blower Wheel Size (Dia x W), in. [mm] EM x 0 [79 x 5] x 0 [79 x 5] x 0 [79 x 5] High Static Blower Wheel Size - [Dia. x W], in. [mm] EM x 0 [79 x 5] n/a n/a oax and Water Piping Water onnections Size - Swivel - in [mm] [5.] [5.] [5.] HW onnection Size - Female Sweat I.D. - in [mm] / [.7] / [.7] / [.7] oax & Piping Water Volume - gal [l].6 [6.].6 [6.]. [8.7] Vertical Air oil Dimensions (H x W), in. [mm] x 5 [8 x 65] x 5 [8 x 65] 6 x 5 [9 x 65] Air oil otal Face Area, ft [m ] 5.6 [0.570] 5.6 [0.570] 6. [0.6] Air oil ube Size, in [mm] /8 [9.5] /8 [9.5] /8 [9.5] Air oil Number of rows Filter Standard - in. [5 mm] Pleated MEV hrowaway, in [mm] x 0 [8 x 76] x 0 [8 x 76] 6 x 0 [9 x 76] Weight - Operating, lb [kg] 5 [60] 6 [6] 85 [75] Weight - Packaged, lb [kg] 7 [69] 8 [7] 05 [8] Horizontal Air oil Dimensions (H x W), in. [mm] 0 x 0 [508 x 06] 0 x 0 [508 x 06] 0 x 5 [508 x ] Air oil otal Face Area, ft [m ] 5.6 [0.570] 5.6 [0.570] 6. [0.6] Air oil ube Size, in [mm] /8 [9.5] /8 [9.5] /8 [9.5] Air oil Number of rows Filter Standard - in. [5 mm] Pleated MEV hrowaway, in [mm] - 0 x 0 [508 x 508] - 0 x [508 x 559] - 0 x 0 [508 x 508] - 0 x [508 x 559] - 0 x 5 [508 x 65] - 0 x [508 x 559] Weight - Operating, lb [kg] 87 [76] 96 [80] 5 [88] Weight - Packaged, lb [kg] 7 [89] 6 [9] 5 [0] 6// WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 8 Page of
9 ontractor: 7 Series 700A Auxiliary Heat atings kw Btu/h Model ompatibility Model Stages Min FM 08V 0V 08V 0V EAL(H)0* ,600, EAL(H)5* ,900 9,00 50 EAL(H)0*. 9. 9,00 65, Air flow level for auxiliary heat (Aux) must be above the minimum cfm in this table /0/7 Order the H part number when installed on horizontal and vertical rear discharge units Auxiliary Heat Electrical Data Supply Heater Amps Min ircuit Amp Max Fuse (USA) Max Fuse (AN) Max K BK Model ircuit 08 V 0 V 08 V 0 V 08 V 0 V 08 V 0 V 08 V 0 V EAL(H)0* Single EAL(H)5* Single L/L L/L Single EAL(H)0* L/L L/L All heaters rated single phase 60 cycle and include unit fan load /0/7 All fuses type D time delay (or HA circuit breaker in USA) Electrical Data Model ated Voltage Voltage Min/Max ompressor Drive HW Internal Pump LA M LA Breaker FLA Ext Loop FLA Blower Motor FLA otal Unit FLA Minimum ircuit Amp Max Fuse HA Breaker /60/ 87/ * /60/ 87/ /60/ 87/ /60/ 87/ *With optional hp Variable Speed EM Motor /6/ ated Voltage of 08/0/60/ HA circuit breaker in USA only All fuses lass K-5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 9 Page of
10 ontractor: 7 Series 700A Blower Performance Data Variable Speed EM Blower Motor Model Max ESP w/hp* Speed Speed Speed 55 L 665 L 70 L 80 L Speed Speed 5 Air Flow Speed 6 Speed 7 Speed 8 Speed 9 Speed H H H H **VS ompressor Speed ** VS ompressor speed is given for the factory default cfm settings. When the cfm default settings are changed it will change the relationship to the compressor speed that is shown in the table. In cooling mode compressor speeds 0- are only available when SuperBoost mode is selected at the thermostat. * Optional hp Variable Speed EM Factory settings are at recommended L, H and Aux positions may be located anywhere within the airflow table L setting should be located within the boldface cfm range H setting MUS be located within the shaded cfm range Aux setting MUS be equal to or greater than H setting Aux setting MUS be equal to or greater than the minimum allowable cfm for the auxiliary heater kit (see auxiliary heat ratings table) fm is controlled within 5% up to the maximum ESP Max ESP includes allowance for wet coil and standard filter Speed 50 Aux 50 Aux 790 Aux 0 Aux Speed /7/ Setting Blower Speed - Variable Speed EM he AB board s Yellow onfig LED will flash the current EM blower speed selections for, low, and high continuously with a short pause in between. he speeds can also be confirmed with the AID ool under the Setup/ EM Setup screen. he Aux will not be flashed but can be viewed in the AID ool. he EM blower motor speeds can be field adjusted with or without using an AID ool. Variable speed EM Setup without an AID ool he blower speeds for only, Low (Y), and High (Y/ Aux) can be adjusted directly at the Aurora AB board which utilizes the push button (SW) on the AB board. his procedure is outlined in the EM onfiguration Mode portion of the Aurora Base ontrol System section. he Aux cannot be set manually without an AID ool. Variable speed EM Setup with an AID ool A much easier method utilizes the AID ool to change the airflow using the procedure below. First navigate to the Setup screen and then select EM Setup. his screen displays the current EM settings. It allows the technician to enter the setup screens to change the EM settings. hange EM Speed Info Blower Only Speed Lo ompressor 6 Hi ompressor 9 Aux Heat 0 Want o hange? Yes Option No Enter the highlighted item using the and buttons and then press the button to select the item. Selecting YES will enter EM speed setup, while selecting will return to the previous screen. EM Speed Setup - hese screens allow the technician to select the, low, high, and auxiliary heat blower speed for the EM blower motor. hange the highlighted item using the and buttons. Press the button to select the speed. EM Speed Info Option Enter EM Speed Info Lo Option ooling Airflow Setup Enter --- EM Only --- he airflow will be adjusted by the chosen amount in cooling mode. Adjustment: -5% Want o hange? Yes Option No Enter EM Speed Info Lo 5 6 Hi Option Enter EM Speed Info Lo 5 6 Hi Option ooling Airflow Setup --- EM Only --- he airflow will be adjusted by the chosen amount in cooling mode. hange Adjustment: -5% Enter Aux Enter After the auxiliary heat speed setting is selected the AID ool will automatically transfer back to the EM Setup screen. ooling Airflow Setup - hese screens allow the technician to select -5%, -0%, -5%, None or +5% change from the heating airflow. hange the adjustment percentage using the and buttons. Press the button to save the change. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 0 Page of
11 ontractor: 7 Series 700A Operating Limits Operating Limits ooling Heating ( F) ( ) ( F) ( ) Air Limits Min. Ambient Air ated Ambient Air Max. Ambient Air Min. Entering Air ated Entering Air db/wb 80.6/66. 7/ Max. Entering Air db/wb 0/8 / Water Limits Min. Entering Water Normal Entering Water Max. Entering Water E: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. he operating limits are dependent upon three primary factors: ) water temperature, ) return air temperature, and ) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation. Definitions Abbreviations and Definitions cfm = airflow, cubic feet/minute EW = entering water temperature, Fahrenheit gpm = water flow in gallons/minute WPD = water pressure drop, psi and feet of water EA = entering air temperature, Fahrenheit (dry bulb/wet bulb) H = air heating capacity, MBtu/h = total cooling capacity, MBtu/h S = sensible cooling capacity, MBtu/h kw = total power unit input, kilowatts H = total heat of rejection, MBtu/h HE = total heat of extraction, MBtu/h HW = hot water generator capacity, MBtu/h EE = Energy Efficient atio = Btu output/watt input OP = oefficient of Performance = Btu output/btu input LW = leaving water temperature, F LA = leaving air temperature, F H = total heating capacity, MBtu/h L = latent cooling capacity, MBtu/h S/ = sensible to total cooling ratio Pressure Drop Model gpm Pressure Drop (psi) 0 F 50 F F 0 F /9/ Notes to Performance Data ables he following notes apply to all performance data tables: Performance ratings are based on 80 F DB/67 F WB EA for cooling and 70 F DB EA for heating. hree flow rates are shown for each unit. he lowest flow rate shown is used for geothermal open loop/well water systems with a minimum of 50 F EW. he middle flow rate shown is the minimum geothermal closed loop flow rate. he highest flow rate shown is optimum for geothermal closed loop systems and the suggested flow rate for boiler/tower applications. he hot water generator numbers are based on a flow rate of 0. gpm/ton of rated capacity with an EW of 90 F. Entering water temperatures below 0 F assumes 5% antifreeze solution. For non-standard EA conditions, apply the appropriate orrection Factor tables. Interpolation between EW, gpm, and cfm data is permissible, extrapolation is not. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
12 ontractor: 7 Series 700A orrection Factor ables Air Flow orrections (ompressor Speeds -) Airflow ooling Heating FM Per on of lg % of Nominal otal ap Sens ap Power Heat of ej Htg ap Power Heat of Ext /9/ Air Flow orrections (ompressor Speeds -) Airflow ooling Heating FM Per on of lg % of Nominal otal ap Sens ap Power Heat of ej Htg ap Power Heat of Ext // ooling apacity orrections Entering Air WB F otal lg ap Sensible ooling apacity Multipliers - Entering DB F Power Input Heat of ejection * * * * * * * * * * * * * * * * * * * * * * E: *Sensible capacity equals total capacity at conditions shown. // Heating apacity orrections Ent Air DB F Heating orrections Htg ap Power Heat of Ext /0/09 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
13 ontractor: 7 Series 700A Antifreeze orrections atalog performance can be corrected for antifreeze use. Please use the following table and note the example given. Antifreeze ype Antifreeze % by wt Heating ooling Pressure Drop EW - F [ ] 0 [-.] 90 [.] 0 [-.] Water Ethylene lycol Propylene lycol Ethanol Methanol WANIN: ray area represents antifreeze concentrations greater than 5% by weight and should be avoided due to the extreme performance penalty they represent. Antifreeze orrection Example Antifreeze solution is Propylene lycol 0% by weight. Determine the corrected heating and cooling performance at 0 F and 90 F respectively as well as pressure drop at 0 F for a 06 operating at 00% capacity. he corrected cooling capacity at 90 F would be: 5,00 MBtu/h x =,09 MBtu/h he corrected heating capacity at 0 F would be: 7,00 MBtu/h x 0.9 =,6 MBtu/h he corrected pressure drop at 0 F and.5 gpm would be: 7.9 feet of head x.70 = 0.0 feet of head WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
14 ontractor: 7 Series 700A Performance Data 06-50% Part Load WPD HEAIN - EA 70 F EW Flow F gpm PSI F Airflow H Power HE LA cfm MBtuh kw MBtuh F WPD OOLIN - EA 80/67 F EW Flow HW OP F gpm PSI F Airflow S S/ Power H M MBtuh cfm MBtuh MBtuh atio kw Btuh EE HW MBtuh Operation not recommended Operation not recommended Operation not recommended Performance capacities shown in thousands of Btuh. 7/0/5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
15 ontractor: 7 Series 700A Performance Data cont % Full Load EW F Flow gpm WPD HEAIN - EA 70 F PSI F Airflow cfm H MBtuh Power kw HE MBtuh LA F OP HW MBtuh EW F Flow gpm WPD OOLIN - EA 80/67 F PSI F Airflow cfm WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 5 Page of MBtuh S MBtuh S/ Power atio kw H MBtuh EE HW MBtuh Operation not recommended Operation not recommended Operation not recommended Performance capacities shown in thousands of Btuh. 7/0/5
16 ontractor: 7 Series 700A Performance Data cont % Part Load EW F Flow gpm WPD HEAIN - EA 70 F PSI F Airflow cfm H Power mbtuh kw HE MBtuh LA F OP HW MBtuh EW F Flow gpm WPD OOLIN - EA 80/67 F PSI F Airflow cfm S MBtuh MBtuh S/ Power atio kw H HW EE MBtuh MBtuh Operation not recommended Operation not recommended Operation not recommended Performance capacities shown in thousands of Btuh. 7/0/5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 6 Page of
17 ontractor: 7 Series 700A Performance Data cont % Full Load EW Flow F gpm WPD HEAIN - EA 70 F EW F Flow gpm WPD OOLIN - EA 80/67 F PSI F Airflow H Power HE LA HW OP PSI F Airflow S S/ Power H cfm mbtuh kw MBtuh F MBtuh cfm MBtuh MBtuh atio kw MBtuh EE HW MBtuh Operation not recommended Operation not recommended Operation not recommended Performance capacities shown in thousands of Btuh. 7/0/5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 7 Page of
18 ontractor: 7 Series 700A Performance Data cont % Part Load EW F Flow gpm WPD HEAIN - EA 70 F EW F Flow gpm WPD OOLIN - EA 80/67 F PSI F Airflow H Power HE LA HW OP PSI F Airflow S S/ Power H cfm mbtuh kw MBtuh F MBtuh cfm MBtuh MBtuh atio kw MBtuh EE HW MBtuh Operation not recommended Operation not recommended Operation not recommended Performance capacities shown in thousands of Btuh. 7/0/5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 8 Page of
19 ontractor: 7 Series 700A Performance Data cont % Full Load WPD HEAIN - EA 70 F WPD OOLIN - EA 80/67 F EW Flow EW Flow F gpm PSI F Airflow H Power HE LA HW OP F gpm PSI F Airflow S S/ Power H HW EE cfm mbtuh kw MBtuh F MBtuh cfm MBtuh MBtuh atio kw MBtuh MBtuh Operation not recommended Operation not recommended Operation not recommended Performance capacities shown in thousands of Btuh. 7/0/5 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 9 Page of
20 ontractor: 7 Series 700A Wiring Schematics Aurora Variable Speed Ext Pump / hp otal 08-0/60/ Variable Speed VS Pump Pump 08-0/60/ Pump Pump P PB E L Orange(9) Brown(0) See Figure for DHW wiring. L K6 K5 L L Violet(8) Violet(7) 5A ircuit Breaker 5A ircuit Breaker L ed L ircuit Breaker ircuit Breaker E ed L L L and L on VS Drive BLOWE UEN ANSDUE () E 7 DISH OM OM () /White(5) ray/white() Brown(06) Orange(05) Brown(7) Brown(6) ray(6) ray(5) FLOW MEE ND reen() OU White() 5D Brown() Purple() Purple(0) White(9) White(8) PEFOMANE OPION 0D ND PWM NA Pump Slave Input/Output VAIABLE SPEED PUMP LOW VOLAE Future Use Smart rid Home Automation P6 LL LA FLOW LW EW P P P HA HA SI P S +5 S +5 OU IN LOOP VS DAA VS PUMP PUMP SLAVE VAIABLE SPEED PUMP LOW VOLAE AXB BOAD ND VA 0-0D SEE DEAIL Brown E: VS PUMP S +5 VS DAA MODULAIN VALVE White E: reen ed MOO X AXB BOAD VS AB BOAD X V+ P8 S85 (+) o Master on VS Drive (-) AID ool ommunicating hermostat A- B+ Status AXB (Aurora Expansion Board) P6 ZONE (+) Modbus Add. ID Future Use (-) Future Use Acc Dip Acc Dip 5 OFF P7 AB (+) SW (-) K K K ON 5 P7 P8 P5 P P0 P5 P HW S SU P SEPPE ANA A DH DIV +5 P9 () White Dehumidification Output White Accessory Output Orange Analog Output 0-0VD Orange E: 9 (0) AUXILIAY (0) HEA Brown(0) BLOWE Brown(0) E: 8 Pink(0) P9 Pink(9) EH F P HO WAE OPION ES LS ALM K5-Alarm AL elay A OM A K6-Acc A N elay LO O/B Y Y W DH P om LED5 S85 NE P8 reen() Unit Power 08-0/60/ JW om LED5 S85 NE - + P7 Violet() (5) F F HI K-Fan elay K- elay LO K- elay S85 EXP P5 Aurora Base ontrol (AB) - + P6 O Brown(5) E ondensate EH PS Orange(0) V SW V Orange() est Mode EH P ed 08V Yellow(6) FP Yellow(7) 0V (8) FP Status LED (9) () () ransformer LP () () () () V HP (5) EVEV FP FP FP FP LPS LPS HPS HPS K-V elay Y Fault LED Yellow /White P FP 5 F/0 F FP 5 F/0 F V B/O Acc Dip Acc Dip 5 Dual/Single L Output ype Future Use onfig LED Y F-A Off PWM FM F P SW On E 6 reen(07) Violet() 5 (0) Yellow(09) EM Blower Motor P PWM FM reen/yellow(08) o P on Electric Heat Board 97P8-0A WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 0 Page of
21 ontractor: 7 Series 700A Wiring Schematics cont. Aurora Variable Speed cont. P9 5 Violet Brown Orange With optional EA Series 0kW Auxiliary Electric Heat Shown 60 AMP BK 60 AMP BK L L L L Pink ray Yellow S L Legend Factory Low voltage wiring Factory Line voltage wiring Light emitting diode - reen Fi eld l ow voltage wiring Field line voltage wiring Optional block D Voltage PB traces Internal junction FB K* Fused Backup Electric Heat elay Qui ck connect terminal hermal Limit Switch P Polarized connector PB - Power block Field wire lug HE - Heater element round Breaker N.O., N.. K K5 ray reen 5 P ray OM K OM K6 ray FB HE S onnects to vari able speed EM motor only OM K OM K7 FB Yellow HE S Yellow OM OM FB HE S K K8 Yellow Pink Pink OM EA Series PB OM Pink FB HE S P P Aux heat stagi ng O EH EH P P on Aurora AB Board E - Use copper o r aluminum conductors. - Use manufacturer s part numb er 9P59-0 (jumper bar assembly) when si ngle source power is required. Jumpers wires are Factory Installed, and are required for auxiliary heat operation. Low voltage wiring LASS. Figure : Optional Internal Hot Water eneration Pump Wiring Schematic DHW Pump (8) OM K6 elay (7) abinet HW Switch ommunicating hermostat o Fossil Fuel Dual Fuel Wiring Diagram Furnace W input Using Field Installed elay Note : Fiel d i nstalled SPS dual fuel rel ay (equired for dual fuel installation) L onnects to L and on AXB Board f rom Foss il Fuel Furnace Purple Notes - Switch blue and red wires for 08V operation. - he blk/wh and gray/wh wires are removed when Aux Heat is installed - Use manufacturer s part number 9P59-0 (jumper bar assembly) when single source power is required. Variable speed pump low voltage harness provided with Variable Speed Flow enter. 5 Low voltage wiring LASS. 6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower. 7 When Auxiliary Heat is field installed the harness will then be connected to the auxiliary heat unit. he auxiliary heat unit will then power the blower. efer to EAS/EAM/EAL Auxiliary Heat kit installation instructions. 8 Brown blower power wire routed through urrent ransducer two times. 9 Field onnected: efer to Installation Manual and Auxiliary Heat Instructions for urrent ransducer installation. 0 ommunication cable routed through Ferrite oroid four times. ompressor power cable routed through Ferrite oroid three times. Variable speed pump power wires to connect the pump to L and L on the AXB board are provided with Variable Speed Flow enter. - Field installed SPS relay required for dual fuel installation. - Wiring harness supplied with valve. EH AB Board VD Page 97P8-0A WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
22 - - - ontractor: 7 Series 700A Wiring Schematics cont. Aurora Variable Speed Drive/EEV Wiring Unit Power 08-0/60/ ompressor Ambient Discharge Line emp Suction Pressure (ed Plug) Discharge Pressure (reen Plug) L L + S-Ambient + ed ed + S-D Brown OM OU 5 VD N/A P-O Brown OM OU 5 VD N/A P- B OM LY- O A- B+ EEV L L Entering Water emp EW OM OU 5 VD N/A Danfoss Variable Speed Drive OM OU 5 VD N/A ed ircuit Breaker ircuit Breaker White White S-AUX ed ed reen E Ferrite oroid Metal Flexible onduit ed (+) Master (-) B+ (+) (-) reen White ed S85 EXP (+) (-) AB P6 o Aurora Board E 0 Ferrite oroid AB 5VA (-) (+) AXB P9 o AXB Board EEV MASE EEV EX. FAN SW S_AMBIEN S_AUX S_D P_O P_ AXB LY L L POWE O VS DIVE VAIABLE SPEED DIVE END VIEWS LA EEV OMM USED USED SUION EMP EEV OIL POWE O OMPESSO EEV OL BOAD 97P8-0B WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
23 ontractor: 7 Series 700A Wiring Schematics cont. Aurora Variable Speed Drive/EEV Wiring cont. k reen ed VS ompressor B+ A- Power KM ed onnector ( Pin) Suction Discharge Line emp Air emp Yellow Yellow ND S Suction emp KM Orange Orange ND S Leaving Air emp (LA) KM Bipolar Stepper Motor + X X Y 5 Y Orange ed Yellow ray VD X X Y Y EEV Output KM9 Danfoss EEV ontrol 5 L - O - K5 - K S - F and F - HE - HP - E to E - LP - Factory Low voltage wiring Factory Line voltage wiring Field low voltage wiring Field line voltage wiring Optional block D Voltage PB traces Junction Quick connect terminal Wire nut Field wire lug round elay ontacts- N.O., N.. Fuse olor identification tape on wire. ompressor ontactor ondensate overflow sensor DHW pump relay Loop pump relay PS Fan Speed elay PS Fan Power elay ompressor Solenoid Fuses Heater element High pressure switch Aux heat stage relays Low pressure switch Legend P PB, PB - PS - V - SW - SW - SW - S - HWL - S - S - WL - hermistor Light emitting diode - reen elay coil apacitor w/ bleed resistor Switch - ondensate overflow Switch - High pressure Switch - Low pressure Polarized connector urrent ransducer () Power blocks Power strip eversing Valve coil DIP package 5 position AXB ES MODE AB Board DIP package 8 position AB Board hermal limit switch Hot water limit sensor Start ontactor Start elay Water oil Limit Sensor Aurora LED Flash odes F Y HP HP LP LP FP FP FP FP EV EV LO HI F F Factory P5 Factory JW - Alarm P P PWM FM EM PWM P SW est V K K Hi K Fan K Alarm K5 Acc K6 Field onnections Off LED FP 5 o F/0 o F FP 5 o F/0 o F Fault V B/O A Dip LED A Dip 5 Dual/Single L Pulse/ontinuous Status eheat/normal P9 LO P Factory Use P AUOA BASE OL Factory Fan onnection O/B Field onnections SW On LED Y onfig Y Y W DH om om A-Fuse P Factory P6 P7 S 85 P8 EH S85 Exp S85 NE EH EH O N/A (+) (-) (+) (-) Slow Flash Fast Flash Flash ode second on and second off 00 milliseconds on and 00 milliseconds off 00 milliseconds on and 00 milliseconds off with a second pause before repeating Fault LED (LED, ed) andom Start Delay (Alternating olors) Normal Mode OFF Status LED (LED, reen) Fast Flash Input Fault Lockout Flash ode onfiguration LED (LED, Yellow) Fast Flash High Pressure Lockout Flash ode Fault LED (LED, ed) Fast Flash Low Pressure Lockout Flash ode onfiguration LED (LED, Yellow) Freeze Detection- FP Flash ode No Software Overide OFF Freeze Detection - FP Flash ode 5 DIP Switch Overide Slow Flash eserved Flash ode 6 Status LED (LED, reen) ondensate Overflow Lockout Flash ode 7 Normal Mode ON Over/Under Voltage Shutdown Flash ode 8 ontrol is Non - Functional OFF Future Use Flash ode 9 est Mode Slow Flash ompressor Monitoring Flash ode 0 Lockout Active Fast Flash Fault- FP and FP Sensor Error Flash ode Dehumidification Mode Flash ode Future Use Flash ode Future Use Flash ode Non-ritical AXB Sensor Error Flash ode Future Use Flash ode ritical AXB Sensor Error Flash ode Load Shed Flash ode 5 Alarm - Hot Water Flash ode 5 ESD Flash ode 6 Fault Variable Speed Pump Flash ode 6 Future Use Flash ode 7 Future Use Flash ode 7 Fault LED (LED, ed) ont. Non-ritical ommunication Error Flash ode 8 Safe Mode - Ambient emperature Sensor Flash ode 9 Fault - ritical ommunication Error Flash ode 9 Fault - Discharge emperature Sensor Flash ode 5 Alarm - Low Loop Pressure Flash ode Fault - Suction Pressure Sensor Flash ode 5 Fault - ommunication EM Fan Motor Error Flash ode Fault - ondensing Pressure Sensor Flash ode 5 Alarm - Home Automation Flash ode Fault - Low Supply Voltage Flash ode 5 Alarm - Home Automation Flash ode Fault - ompressor Out of Envelope Flash ode 55 Fault - EEV Error Flash ode 5 Fault - Over urrent Flash ode 56 Derate - Drive emperature Flash ode Fault - Over/Under Voltage Flash ode 57 Derate - High Discharge emperature Flash ode Fault - High Drive emperature Flash ode 58 Derate - Low Suction emperature Flash ode Fault - Drive Internal Error MO/AO Flash ode 59 Derate - Low ondensing Pressure Flash ode Fault - Multiple Safe Modes Flash ode 6 Derate - High ondensing Pressure Flash ode 5 Fault - Loss of harge Flash ode 7 Derate - Outer Power Limit Flash ode 6 Safe Mode - Suction emperature Sensor Flash ode 7 Safe Mode - EEV (Indoor) ommunication Flash ode 7 Safe Mode - LA emperature Sensor Flash ode 7 Safe Mode - EEV (Outdoor) ommunication Flash ode 8 Safe Mode - Max Operating Pressure Flash ode 7 AXB Accessory DIP Se ngs SW- SW-5 DESIPION ON ON ycles with Blower OFF ON ycles with rst stage compressor or compressor spd - ON OFF ycles with second stage of compressor or comp spd 7- OFF OFF ycles with DH from AB board ES LS ALM AL A c A no A nc LO O/B Y Y W DH AB SW Accessory elay DESIPION SW- SW-5 ycle with Blower ON ON ycle with ompressor OFF OFF Water Valve Slow Opening ON OFF ycle with omm. -stat Hum md OFF ON 97P8-0B WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
24 ontractor: 7 Series 700A Wiring Schematics cont. Aurora Variable Speed with UP Ext Pump Pump Pump / hp otal 08-0/60/ Variable Speed VS Pump Pump 08-0/60/ P PB E L Or ang e(9) Brown(0) L See Figure for DHW wiring. K6 K5 L L Violet(8) Violet(7) 5A ircuit Breaker 5A ircuit Breaker L ed L ircuit Breaker ircuit Breaker E ed L L L and L on VS Drive BLOWE UEN ANSDUE () E 7 DISH OM OM () /White(5) ray/white() Brown(06) Or ang e(05) Brown(7) Brown(6) ray(6) ray(5) FLOW MEE ND r een() OU White() 5D Brown() Purple() Purple(0) White(9) White(8) PEFOMANE OPION 0D ND PWM NA Pump Sl ave Input/Output VAIABLE SPEED PUMP LOW VOLAE Future Use Smart rid Home Automati on P6 LL LA FLOW LW EW P P P HA HA SI S +5 S +5 OU IN P LOOP VS DAA VS PUMP PUMP SLAVE VAIABLE SPEED PUMP LOW VOLAE AXB BOAD ND VA 0-0D SEE DEAIL Brown E: VS PUMP S +5 VS DAA MODULAIN VALVE White E: reen ed MOO X AXB BOAD VS AB BOAD X V+ P8 S85 (+) UP ontroller o Master on VS Drive (-) A- B+ P6 ZONE (+) Status AXB (Aurora Expansion Board) ZS Sensor Modbus Add. ID Future Use (-) Future Use Acc Dip Acc Dip 5 P7 AB (+) SW (-) K K K OFF ON 5 P7 P8 P5 P P0 P5 P HW S SU P SEPPE ANA A DH DIV +5 P9 () White Dehumidification Output White Accessory Output Or ang e Analog Output 0-0VD Or ang e E: 9 (0) AUXILIAY (0) HEA Brown(0) BLOWE Brown(0) E: 8 Pink(0) P9 Pink(9) EH F P HO WAE OPION ES LS ALM K5-Alarm AL elay A OM A K6-Acc A N elay LO O/B Y Y W DH P om LED5 S85 NE P8 r een() Unit Power 08-0/60/ JW Violet() (5) F F P5 HI LO K-Fan elay om LED5 S85 NE - + P7 K- elay K- elay Aurora Base ontrol (AB) S85 EXP - + P6 O Brown(5) E ondensate PS Or ang e(0) V V Or ang e() ed 08V Yellow(6) FP Yellow(7) 0V (8) FP (9) () ransformer LP () () () () () V HP (5) EVEVFP FP FP FP LPS LPSHPSHPSP K-V elay SW est Mode EH EH P Y Status LED Faul t LED Yellow /White F-A PWM FM P Off On FP 5 F/0 F FP 5 F/0 F V B/O Acc Dip Acc Dip 5 5 Dual/Single 6 L Output ype 7 Future Use 8 SW onfig LED Y F E 6 r een(07) Violet() 5 (0) Yellow(09) EM Blower Motor P PWM FM r een/yellow(08) P o P on Elec tric Heat Board WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 Page of
25 ontractor: 7 Series 700A Wiring Schematics cont. Aurora Variable Speed with UP cont. P9 5 Violet Brown Orange With optional EA Series 0kW Auxiliary Electric Heat Shown 60 AMP BK 60 AMP BK L L L L Pink ray Yellow S L Legend Factory Low voltage wiring Factory Line voltage wiring Light emitting diode - reen Fi eld l ow voltage wiring Field line voltage wiring Optional block D Voltage PB traces Internal juncti on FB K* Fused Backup Electric Heat elay Qui ck connect terminal hermal Limi t Switch P Polarized connector PB - Power block Field wire lug HE - Heater element round Breaker N.O., N.. K K5 ray reen 5 P ray OM K OM K6 ray FB HE S onnects to vari able speed EM motor only OM K OM K7 FB Yellow HE S Yellow OM OM FB HE S K K8 Yellow Pink Pink OM EA Series PB OM Pink FB HE S P P Aux heat stagi ng O EH EH P P on Aurora AB Board E - Use copper o r aluminum conductors. - Use manufacturer s part numb er 9P59-0 (jumper bar assembly) when si ngle source power is required. Jumpers wires are Factory Installed, and are required for auxiliary heat operation. Low voltage wiring LASS. Figure : Optional Internal Hot Water eneration Pump Wiring Schematic DHW Pump (8) OM K6 elay (7) abinet HW Switch ommunicating hermostat o Fossil Fuel Dual Fuel Wiring Diagr am Furnace W input Using Field Installed elay Note : Fiel d i nstalled SPS dual fuel rel ay (equired for dual fuel installation) L onnects to L and on AXB Board f rom Foss il Fuel Furnace Purple Notes - Switch blue and red wires for 08V operation. - he blk/wh and gray/wh wires are removed when Aux Heat is installed - Use manufacturer s part number 9P59-0 (jumper bar assembly) when single source power is required. Variable speed pump low v oltage harnes s provided with Variable Speed Flow enter. 5 Low voltage wiring LASS. 6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower. 7 When Auxiliary Heat is field installed the harness will then be connected to the auxiliary heat unit. he auxiliary heat unit will then power the blower. efer to EAS/EAM/EAL Aux iliary Heat kit installation instructions. 8 Brown blower power wire routed through urrent ransducer two times. 9 Field onnected: efer to Installation Manual and Auxiliary Heat Instructions for urrent ransducer installation. 0 ommunication cable routed through Ferrite oroid four times. ompressor power cable routed through Ferrite oroid three times. Variable speed pump power wires to connect the pump to L and L on the AXB board are provided with Variable Speed Flow enter. - Field installed SPS relay required for dual fuel installation. - Wiring harness supplied with valve. EH AB Board VD Page WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 5 Page of
26 ontractor: 7 Series 700A Wiring Schematics cont. Aurora UP o AB - P Or ang e ed White r een Brown Yellow BAnet or N Network on nections Devices Must Be Wired in Daisy hain onfiguration NE+ NE- NE- OM NE+ OM POWE NE+ NE- OM LE D X LE D POWE ND VA NE+ LE D X FO MA BA NE- N/ N/ Signal ND N E+ N E- +V N E LE D7 W X W LO N ADAPE PO LE D6 X ND LN+ LN- + /S LOA L A ESS LE D UN LE D5 E ON EN S ONE S ommunication Options E MA Address Setting ZS Sensor Addr: 0 ND N E+ N E- +V ZS Sensor Addr: ND N E+ N E- +V ZS Sensor Addr: ND N E+ N E- +V ZS Sensor Information Zone Sensors can be wired in daisy chain as shown or in a star or hybrid configuration. Maximum of 5 sensors per UP. Maximum allowable load 0mA. See the UP install manual for possible sensor combinations. Notes. Use DIP Switches 5 8 to change communication protocol and DIP switches to change BAnet baud rate. DIP switches factory set for BAnet MSP (s) DIP Switch Value 8 ON Each ZS sensor must have a unique address, but the addresses do not need to be sequential. Use the DIP switches on the back of the ZS sensor to set an address from 0 to. (0 is the factory default.) Each DIP switch has the value shown in the figure to the left. urn on as many DIP switches as you need so that their total value equals the address. Legend Factory Low Voltage Wiring Field Low Voltage Wiring J5 onnector 5678 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at for latest design and SD700AN /7 6 Page of
7 Series 700A11 Installation Manual
700A eothermal Heat Pump -40A efrigerant, 4, 5 Ton Variable Speed Installation Information Water Piping onnections Hot Water enerator onnections 7 Series 700A Installation Manual Electrical Startup Procedures
More informationAIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15
AI HANDLE -0A efrigerant - Tons Submittal Data English Language/IP Units SD00HN 0/ ontractor: ENVISIN AI HANDLE - Tons Model Nomenclature - - - 0 NAH 0 * 00 0 Model NAH Envision Series Air Handler Unit
More informationGEOTHERMAL/WATER SOURCE OUTDOOR SPLIT HEAT PUMP 2 TO 6 TONS DUAL CAPACITY SPECIFICATION CATALOG
GEOTHEMAL/WATE SOUE OUTDOO SPLIT HEAT PUMP TO 6 TONS DUAL APAITY SPEIFIATION ATALOG Table of ontents Model Nomenclature.... AHI Data... 6- Design Features... 8 NDS Split Features... 9 Physical Data...
More information7 Series 700A11 Installation Manual
700A eothermal Heat Pump -0A efrigerant,, 5 Ton Variable Speed Installation Information Water Piping onnections Hot Water enerator onnections 7 Series 700A Installation Manual Electrical Startup Procedures
More informationEnvision Air Handler Specification Catalog
Air Handler Design Features Factory ptions Accessories Dimensional Data Physical Data Performance Data Engineering uide Specifications Envision Air Handler Specification atalog S00HN 0/ ENVISIN AI HANDLE
More informationSPECIFICATION CATALOG
SPEIFIATIN ATAL ETHEMAL HEAT PUMPS AFFDABLE ENEWABLE LEAN ASTN SEIES AI HANDLE ASTN SEIES AI HANDLE SPEIFIATIN ATAL Table of ontents Air Handler Nomenclature...........................................................
More information7 Series 50Hz 700A11 Installation Manual
700A eothermal Heat Pump - 50Hz -40A efrigerant 009, 0, 05 kw Variable Speed Installation Information Water Piping onnections Hot Water enerator onnections Electrical Startup Procedures 7 Series 50Hz 700A
More informationNAH Series HYDRONIC AIR HANDLER 2 TO 5 TONS. Submittal Data English Language IP/Metric Units SD1028HG1 05/17
HYDNI AI HANDLE T TNS Submittal Data English Language IP/Metric Units SD0H 0/ ontractor: Model Nomenclature - Tons 0Hz - - - 0 NAH 0 * 00 0 H Model NAH Unit apacityacity 0 MBTUH 0 MBTUH 0 MBTUH 00 MBTUH
More informationHeating and Air Conditioning
Heating and Air onditioning INSTALLATION MANUAL AFFINITY EOTHEMAL HEAT PUMPS VAIABLE SPEED MODELS: YAFV06-060 ( THU 5 NOMINAL TONS) Due to continuous product improvement, specifications are subject to
More information5 Series 500A11 Installation Manual
500A eothermal Heat Pump -40A efrigerant,.5,,.5,,.5, 4, 5, 6 Ton Single Speed,, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Hot Water enerator erator onnections 5 Series 500A
More informationSpecification Catalog. 7 Series 700A11. Geothermal heat pump 3-5 ton (variable speed)
Specification atalog 7 Series 700A eothermal heat pump 3-5 ton (variable speed) 7 SEIES 700A SPEIFIATION ATALO Table of ontents Model Nomenclature... 5 AHI/ISO 356- Performance atings.... 6 7 Series Design
More informationEnvision Series 30 Ton Installation Manual
OMMEIAL 30 TON Water Source/eothermal Heat Pump -410A efrigerant ommercial 30 TON Installation Information Water Piping onnections Hot Water onnections Electrical Startup Procedures Troubleshooting Envision
More informationNAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections
NAH Series Air Handler Installation Information Water Piping onnections Electrical onnections Startup Procedures Preventive Maintenance NAH Series Hydronic Air Handler Installation Manual IM0H 0/ NAH
More informationRCL Series. RCL Series Low Sill Console Engineering i Guide
L Series LOW SILL ONSOLE eothermal/water Source Heat Pump -410A efrigerant 0.75-1.5 Ton Single Speed Design Features Factory Options Accessories Dimensional Data Physical Data Performance Data Engineering
More informationRC Series. RC Series Engineering Guide. CONSOLE Geothermal/Water Source Heat Pump R-410A Refrigerant Ton Single Speed.
Series ONSOLE eothermal/water Source Heat Pump -410A efrigerant 0.75-1.5 Ton Single Speed Design Features Series Engineering uide Factory Options Accessories Dimensional Data Physical Data Performance
More informationSynergy3D Installation Manual
Geothermal Heat Pump with Water Heating for adiant Floor Applications -40A efrigerant 3, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Synergy3D Installation Manual Hot Water
More informationEnvision Low Sill Console Installation Manual
LOW SILL ONSOLE eothermal/water Source Heat Pump -410A efrigerant 0.75-1.5 Ton Single Speed Installation Information Water Piping onnections Electrical Startup Procedures Troubleshooting Preventive Maintenance
More informationARBOR BASE SERIES COMMERCIAL. Arbor Base Series Installation ti Manual. Water Source/Geothermal Heat Pump R-410A Refrigerant Commercial 0.
ABO BASE SEIES OMMEIAL Water Source/eothermal Heat Pump -410A efrigerant ommercial 0.75-6 Ton Installation Information Water Piping onnections Hot Water onnections Arbor Base Series Installation ti Manual
More informationVersatec Compact 50 Hz Series Installation Manual
ommercial 002-017kW eothermal/water Source Heat Pump 50Hz Installation Information Water Piping onnections Electrical Startup Procedures Troubleshooting Preventive Maintenance Versatec ompact 50 Hz Series
More informationINSTALLATION MANUAL AFFORDABLE RENEWABLE CLEAN ASTON SERIES AIR HANDLER GEOTHERMAL HEAT PUMPS
INSTALLATION MANUAL EOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN ASTON SEIES AI HANDLE Table of ontents Model Nomenclature.............................................................. Initial Inspection..................................................................
More informationSpecification Catalog. 5 Series 500RO11. Outdoor Split Geothermal Heat Pump 2-6 ton (dual capacity)
Specification atalog 5 Series 500O11 Outdoor Split eothermal Heat Pump 2-6 ton (dual capacity) 5 SEIES 500O11 SPEIFIATION ATALO Table of ontents The 5 Series Outdoor Split.........................................................
More informationSPECIFICATION CATALOG
SPEIFIATION ATALO HEATIN OOLIN HOT WATE www.geostar-geo.com AFFODABLE ENEWABLE LEAN ASTON SEIES OUTDOO PAKAED UNIT ASTON SEIES PAKAED OUTDOO HEAT PUMP SPEIFIATION ATALO Table of ontents Model Nomenclature............................................................
More informationLegend Series Installation Manual
ESIDENTIAL Geothermal/Water Source Heat Pump -410A efrigerant 2-6 Tons Installation Information Water Piping onnections Hot Water Generator onnections Legend Series Installation Manual Electrical Startup
More informationSPECIFICATION CATALOGUE. Premium Variable Speed Forced Air Geothermal Comfort System. TEC-SPC-V-0213v1
Premium Variable Speed Forced Air eothermal omfort System eothermal Heat Pumps -40A efrigerant 3-5 35 Ton Variable Speed Design Features Unit omponents Performance Dimensional Data Physical Data Electrical
More informationARBOR COMPACT SERIES COMMERCIAL. Arbor Compact Series Installation ti Manual
ABO OMPAT SEIES OMMEIAL Water Source/eothermal Heat Pump -410A efrigerant ommercial 0.75-6 Ton Installation Information Water Piping onnections Hot Water onnections Electrical Arbor ompact Series Installation
More information*20D082-05NN* 20D082-05NN
2506 South Elm Street Greenville, IL 62246 www.enertechgeo.com info@enertechmfg.com HT Models Packaged Water-to-Air Horizontal Heat Pumps Engineering Data and Installation Manual Rev.: 25 May 2012D P/N:
More informationINSTALLATION MANUAL AFFORDABLE RENEWABLE CLEAN ASTON SERIES OUTDOOR SPLIT HEATING COOLING HOT WATER.
INSTALLATION MANUAL HEATIN OOLIN HOT WATE www.geostar-geo.com AFFODABLE ENEWABLE LEAN ASTON SEIES OUTDOO SPLIT ASTON DUAL-APAITY OUTDOO SPLIT SEIES INSTALLATION MANUAL Table of ontents Model Nomenclature..............................................................
More informationPremier Installation Manual
eothermal/ater Source Heat s / thru on Installation Information Premier Installation Manual ater Piping onnections Desuperheater onnections Electrical Startup Procedures roubleshooting Preventive Maintenance
More informationINDOOR PACKAGED EQUIPMENT COMMERCIAL WATER SOURCE / GEOTHERMAL HEAT PUMP SERIES RB R-410A TON
INDOO PAKAED EQUIPMENT INSTALLATION, OPEATION, MAINTENANE Supersedes: 46.00-NOM7 (0) Form 46.00-NOM7 (54) OMMEIAL WATE SOUE / EOTHEMAL HEAT PUMP SEIES B -40A 0.5-6 TON Issue Date: May 0, 04 Table of ontents
More informationSPECIFICATION CATALOG. Console - 50Hz Commercial 2 to 5 kw. Geothermal/Water Source Heat Pump
SPEIFIATION ATALO onsole - 50Hz ommercial 2 to 5 kw eothermal/water Source Heat Pump Table of ontents Model Nomenclature.............................................................. 4 AHI Data......................................................................
More informationVersatec Base Series Installation Manual
ommercial 0.5 to 6 Ton eothermal/water Source Heat Pump Installation Information Water Piping onnections Electrical Startup Procedures Troubleshooting Versatec Base Series Installation Manual Preventive
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationINSTALLATION, OPERATION, MAINTENANCE Supersedes: NOM9 (314) Form NOM1 (317) RCL SERIES LOW SILL CONSOLE SINGLE SPEED 0.75 TON - 1.
WATE SOUE HEAT PUMP INSTALLATION, OPEATION, MAINTENANE Supersedes: 146.00-NOM9 (314) Form 146.09-NOM1 (317) L SEIES LOW SILL ONSOLE SINLE SPEED 0.75 TON - 1.5 TON -410A Issue Date: March 29, 2017 IMPOTANT!
More informationSynergy3D Installation Manual
Geothermal Heat Pump with Water Heating for adiant Floor Applications -0A efrigerant 3-6 Ton Installation Information Water Piping onnections Synergy3D Installation Manual Hot Water Generator onnections
More informationSPECIFICATION CATALOG. Low Sill Console 0.75 to 1.5 Ton. Geothermal/Water Source Heat Pump
SPEIFIATION ATALO Low Sill onsole 0.75 to 1.5 Ton eothermal/water Source Heat Pump ENVISION LOW SILL ONSOLE SPEIFIATION ATALO Table of ontents Model Nomenclature..............................................................
More informationVersatec Ultra NSW Installation Manual
NSW eothermal Hydronic Heat Pump Installation Information Water Piping onnections Electrical Data Startup Procedures Preventive Maintenance Versatec Ultra NSW Installation Manual IM2556WN 06/16 VESATE
More informationEnvision Commercial Tons Installation Manual
OMMEIAL Geothermal/Water Source Heat Pump -0A efrigerant 0.- Tons Single Speed - Tons Dual apacity Installation Informationon Water Piping onnections Hot Water onnectionsons Electrical Startup Procedures
More information3 Series 300A11 Installation Manual
300A11 eothermal Heat Pump R-410A Refrigerant 2, 3, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Hot Water enerator erator onnections 3 Series 300A11 Installation Manual Electrical
More informationVersatec Base Series Installation Manual
ommercial 0.5 to 6 Ton eothermal/water Source Heat Pump Installation Information Water Piping onnections Electrical Startup Procedures Troubleshooting Versatec Base Series Installation Manual Preventive
More informationASTON LOW SILL SERIES
ASTON LOW SILL SEIES OMMEIAL Water Source/eothermal Heat Pump -410A efrigerant ommercial 0.75-6 Ton Installation Information Water Piping onnections Hot Water onnections Electrical Aston Low Sill Series
More informationVersatec Variable Speed Installation Manual
ommercial Water Source/eothermal Heat Pump -410A efrigerant 3-6 Tons Installation Information Water Piping onnectionsns Hot Water onnections Electrical Startup Procedures Troubleshooting Preventive Maintenance
More informationHeating and Air Conditioning
Heating and Air onditioning INSTALLATION MANUAL LX BASE OMMEIAL EOTHEMAL/ WATE SOUE HEAT PUMPS SINLE APAITY MODELS: YBS006-070 (.50 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications
More informationSPECIFICATION CATALOG. Low Sill Console 0.75 to 1.5 Ton. Geothermal/Water Source Heat Pump
SPEIFIATION ATALO Low Sill onsole 0.75 to 1.5 Ton eothermal/water Source Heat Pump ENVISION LOW SILL ONSOLE SPEIFIATION ATALO Table of ontents Model Nomenclature..............................................................
More informationSPECIFICATION CATALOG. Commercial 10 to 15 Ton. Water Source/Geothermal Heat Pump
SPEIFIATION ATALOG ommercial 10 to 15 Ton Water Source/Geothermal Heat Pump Table of ontents Model Nomenclature.............................................................. 4 Electrical Availability..............................................................
More information5 Series 500R11 Installation Manual
50011 Indoor Split eothermal Heat Pump -410A efrigerant 2, 2.5, 3, 3.5, 4, 5, 6 Ton Single Speed 2, 3, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Hot Water eneration onnections
More informationHeating and Air Conditioning
Heating and Air onditioning INSTALLATION MANUAL AFFINITY INDOO SPLIT EOTHEMAL HEAT PUMPS SINLE AND DUAL APAITY MODELS: YAZS022-070 (2 THU 6 NOMINAL TONS) YAZT026-072 (2 THU 6 NOMINAL TONS) Due to continuous
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationG Series Geothermal Indoor Split Heat Pump R-410A Refrigerant 2-6 Tons Single Speed 2-6 Tons Dual Capacity
Series eothermal Indoor Split Heat Pump -40A efrigerant - 6 Tons Single Speed - 6 Tons Dual apacity Installation Information Water Piping onnections Hot Water enerator onnections Electrical Startup Procedures
More informationSPECIFICATION I ICAT. Commercial 30 Ton. Water Source/Geothermal Heat Pump
SPEIFIATION I IAT ION ATA O ommercial 30 Ton Water Source/eothermal Heat Pump ENVISION SEIES 30 TON SPEIFIATION ATA Table of ontents Model Nomenclature.............................................................
More informationDUAL CAPACITY HEATING COOLING HOT WATER
I N S T A L L A T I O N M A N U A L DUAL APAITY HEATIN OOLIN HOT WATER www.geostar-geo.com geo. AFFORDABLE RENEWABLE LEAN MANOLIA PLUS SERIES Table of ontents Model Nomenclature...............................................................
More informationEnvision Console Installation Manual
ONSOLE eothermal/water Source Heat Pumps -410A efrigerant 0.75-1.5 Ton Single Speed Installation Information Water Piping onnections Electrical Startup Procedures Envision onsole Installation Manual Troubleshooting
More informationSPECIFICATION CATALOG. Commercial 3 to 6 Ton. Water Source/Geothermal Heat Pump
SPEIFIATION ATALOG ommercial 3 to 6 Ton Water Source/Geothermal Heat Pump Table of ontents Model Nomenclature.............................................................. 4 Electrical Availability..............................................................
More informationNEW Series 504W11 Installation Manual
504W11 eothermal Hydronic Heat Pump 3 to 6 Tons NEW Series Installation Information Water Piping onnections Electrical Data Startup Procedures Preventive Maintenance NEW Series 504W11 Installation Manual
More informationLRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS
Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged
More informationASTON SERIES SINGLE HYDRONIC
ASTON SEIES SINLE HYDONI O M M E I A L U N I T S Proof# Distributed eturn by Approved to Publish As Is Project Manager VP of Engineering Approved to Publish With Marked orrections Project Manager VP of
More informationRK SERIES WATER SOURCE HEAT PUMP 0.75 TON - 6 TON
INDOO PAKAED EQUIPMENT INSTALLATION, OPEATION & MAINTENANE Supersedes: 146.08-NOM1 (317) Form 146.08-NOM1 (318) K SEIES WATE SOUE HEAT PUMP 0.75 TON - 6 TON -410A Issue Date: March 29, 2018 Table of ontents
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationINSTALLATION, OPERATION, MAINTENANCE Supersedes: NOM5 (1112) Form NOM5 (616) GEOTHERMAL HYDRONIC HEAT PUMP MODEL RH 1.
INDOO PAKAED EQUIPMENT INSTALLATION, OPEATION, MAINTENANE Supersedes: 146.00-NOM5 (1112) Form 146.00-NOM5 (616) EOTHEMAL HYDONI HEAT PUMP MODEL H 1.5 TON - 6 TON -410A Issue Date: June 8, 2016 IMPOTANT!
More informationHEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps
HEAT CONTROLLER, INC. ENGINEERING DESIGN GUIDE HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax
More informationTranquility Console (TRC) Series Submittal Data
Tranquility Console (TRC) Series Submittal Data Models TRC09-18 60Hz - HFC-410A *LC386* LC386 Rev.: June 19, 2017 Table of Contents TRC Console Series Unit Features 3 Selection Procedure 4 TRC Series Nomenclature
More informationSPECIFICATION CATALOG. Commercial kW. Geothermal/Water Source Heat Pump 50Hz
SPEIFIATION ATALO ommercial 005-017 eothermal/water Source Heat Pump 50Hz VESATE BASE SEIES SPEIFIATION ATALO Table of ontents Model Nomenclature..............................................................
More informationTECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)
TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409
TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal
More informationINSTALLATION, OPERATION, & MAINTENANCE MANUAL
Premium Forced Air eothermal omfort System eothermal Heat Pumps -0A efrigerant -6 Ton Dual apacity Installation n Information Water Piping onnections Hot Water enerator onnections Electrical Startup Procedures
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS
DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationInstallation Instructions WARNING WARNING. Variable Speed High Efficiency Blower Kit for Gas Furnace Applications 3. INSTALLATION
Installation Instructions Variable Speed High Efficiency Blower Kit for Gas Furnace Applications ANING To avoid the risk of electrical shock, personal injury, or death, disconnect electrical power before
More informationProduct Data. Features/Benefits. 50KQA, KQD Standard and Low Temperature Console Water Source Heat Pumps. 1/2 to 1 1/2 Nominal Tons
Product Data 0KQA, KQD Standard and Low Temperature onsole Water Source Heat Pumps / to / Nominal Tons TM Single-Package onsole Water Source Heat Pump with self-contained line voltage thermostats. System
More informationSPECIFICATION CATALOG
SPEIFIATION ATALO EOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN ASTON SINLE HYDONI UNIT WITH ASTON SINLE HYDONI WITH OPTIHEAT SPEIFIATION ATALO Table of ontents Model Nomenclature..............................................................
More informationINSTALLATION MANUAL MODELS: E30 SERIES SAVE THIS MANUAL FOR FUTURE REFERENCE
INSALLAION MANUAL DOWNFLOW SINLE AND WO SAE ELEI FUNAE WIH: FAO INSALLED ELEI HEA, O NO HEA MODELS WIH FIELD INSALLED ELEI HEA KIS MODELS: E0 SEIES LIS OF SEIONS eneral 7 Line Voltage and ontrol Box Wiring
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationVersatec Installation Manual
Water-to-Water Heat Pumps 3, 5, 7, 10 Ton apacity Installation Information Versatec Installation Manual Water Piping onnections Electrical onnections Startup Procedures Preventive Maintenance IM1355 11/06
More informationSPECIFICATION CATALOG. NSKW Commercial 1.5 to 6 Tons. Water Source/Geothermal Heat Pump
SPEIFIATION ATALO NSKW ommercial 1.5 to 6 Tons Water Source/eothermal Heat Pump Table of ontents Model Nomenclature.............................................................. 4 The Versatec Ultra NSKW........................................................
More informationNDS Installation Manual
Geothermal/Water Source Outdoor Split Heat Pump to Tons Dual apacity NDS Installation Manual Installation Information Water Piping onnections Electrical Data Startup Procedures Troubleshooting Preventive
More informationHeating and Air Conditioning
Heating and Air onditioning INSTALLATION MANUAL AFFINITY EOTHEMAL HEAT PUMPS DUAL APAITY MODELS: YAP026-072 (2 THU 6 NOMINAL TONS) Due to continuous product improvement, specifications are subject to change
More informationHeating and Air Conditioning
Heating and Air onditioning INSTALLATION MANUAL LX ULTRA OMMERIAL EOTHERMAL/ WATER SOURE HEAT PUMPS SINLE APAITY MODELS: YS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationARBOR SERIES COMMERCIAL. Arbor Series Installation ti Manual. Water Source/Geothermal Heat Pump R-410A Refrigerant Commercial 0.
ARBOR SERIES OMMERIAL Water Source/eothermal Heat Pump R-40A Refrigerant ommercial 0.75-6 Ton Installation Information Arbor Series Installation ti Manual Water Piping onnections Hot Water onnections Electrical
More informationTranquility 30 Two-Stage (TT) Series
Tranquility 30 Two-Stage (TT) Series Submittal Data Models TT/H/V 026-072 60Hz - HFC-410A *LC1020* LC1020 Rev.: November 18, 2016 Table of Contents Two- Stage TT Series Unit Features 3 Selection Procedure
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL
Premium Hydronic System H Series HS -410A efrigerant Single Stage 1.5-6 Ton Installation Information on Water Piping onnections nect n Electrical Startup Procedures es Troubleshooting oting Preventative
More informationInstallation Guide ProR221J, ProR212J, ProR321J and ProR312J
ProZone I n t e l l i g e n t Z o n i n g Zones See table below. ompatible Equipment All panels operate with gas/electric systems, conventional heat pumps and dual fuel heat pumps. Equipment Selection
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60
Heating, ooling and Indoor Air Quality Systems ESP Variable Speed Heat Pump 3 Ton ESP-36 5 Ton ESP-60 Installation and Operation www.hi-velocity.com Module-VAR-Variable-Speed-Heat-Pump-060118 Installation
More informationCFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH
CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationDH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil
DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED
More information5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD
5.0 AI HANDLE EQUIPPED WITH THE OMFOT ONTOL 2 SYSTEM INTEFAE BOAD FIGUE 8 THE AI HANDLE OMFOT ONTOL 2 SYSTEM ONTOL BOAD The HPN-series of air handlers are designed to operate with conventional 24VA controls
More informationVersatec Variable Speed Ton Installation Manual
ommercial Water Source/Geothermal Heat Pump -410A efrigerant 10-15 Tons Installation Information Water Piping onnections Electricall Startup Procedures Troubleshooting Preventive Maintenance Versatec Variable
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationHydroZone Installation Manual
Hydronic omfort Zoning System 4, 8, and 12 Zone apacity Installation Information HydroZone Installation Manual Thermostat Installation Electrical Startup rocedures Wiring Schematics IM1550EW 11/10 HDZNE
More informationProduct Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationVersatec Ultra Series Installation Manual
ommercial eothermal/water Source Heat Pump R-40A Refrigerant 0.75-6 Tons Installation Information Water Piping onnections Hot Water onnections Electrical Startup Procedures Versatec Ultra Series Installation
More informationWall Mounted Air Conditioners with Gas Heat Models AVGA
PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationCWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH
CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal
More informationSPECIFICATION CATALOG
SPEIFIATION ATALO EOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN ASTON SINLE HYDONI UNIT Table of ontents Model Nomenclature.............................................................. The Single Speed
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationGENERAL ELECTRIC VERTICAL PACKAGED UNITS
GENERAL ELECTRIC VERTICAL PACKAGED UNITS APF Series APF036 thru APF060 3 TR thru 5 TR 10 kw thru 17.5 kw GE_APF_Series.indd 1 CONTENTS Model decoding 3 Unit features 4-5 General data 6 Cooling capacities
More informationDM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h
Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationGeneral Description. Operation
ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication
More information