Wiring Diagrams Units Produced After April 20, 2009
|
|
- Chloe Fletcher
- 5 years ago
- Views:
Transcription
1 UNIT 38AH Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, , 380/ INDEX Fig. Unit 38AH with Two-Stage Thermostat One 38AH Dual-Circuit Condensing Unit with ModuPanel Control Two 38AH Dual-Circuit Condensing Units with ModuPanel Control AH0-034 Air-Cooled Condensing Units 50/60 Hz DIAGRAM TYPE FIGURE NO. LABEL DIAGRAM NO. Component Arrangement 1 38AH Power Schematic 2 38AH Component Arrangement 3 38AH Power Schematic 4 38AH Component Arrangement 5 38AH Power Schematic 6 38AH Component Arrangement 7 38AH Power Schematic 8 38AH AFR Airflow Relay AFS Airflow Switch ATS Air Temperature Switch C Contactor, Compressor CB Circuit Breaker CH Crankcase Heater CM Control Module COMP Compressor COTP Compressor Overtemperature Protection CR Control Relay DU Dummy EQUIP Equipment FC Fan Contactor FIOP Factory-Installed Option FM Fan Motor FR Fan Relay FU Fuse GND Ground HPS High-Pressure Switch IFC LLSV LPS MMF MMPT MPR NEC OPS PL PRI RLA SEC TB TRAN U VAV LEGEND (For Fig. 1-11) Indoor (Evaporator) Fan Contactor Liquid Line Solenoid Valve Low-Pressure Switch Motormaster Fuse Motormaster Pressure Transducer ModuPanel Relay National Electrical Code (U.S.A. Standard) Oil Pressure Switch Primary Primary Rated Load Amps Secondary Terminal Block Transformer Unloader Variable Air Volume Plug Receptacle Terminal Block Connection Unmarked Terminal Marked Splice Unmarked Splice Factory Wiring Field Control Wiring Field Power Wiring Indicates common potential. (Does not represent wiring.) Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No Printed in U.S.A. Form 38AH-9W Pg Replaces: 38AH-8W
2 1. For TRAN2: for 208/ v connect to H3; for 460 v, connect to H4. 2. TRAN 1: for 208/ v, connect to orange lead; for 460 v, connect to black lead. 3. Compressor and fan motors are thermally protected. Threephase motors are protected against primary single-phasing conditions. 4. Replacement of original wires must be with type 90 C wire or its equivalent. 5. Factory wiring is in accordance with NEC. Field modifications or additions must be in compliance with all applicable codes. 6. Wiring for field power supply must be rated 75 C. Use copper, copper-clad aluminum, or aluminum conductors. 7. FU1 is used on 208/-3-60 units only. 8. Thermostat wire between RC and TB2-1 is not connected when AFS is used. 9. Control circuit power (va) available at TB2 is as follows: VA ITEM 40 Standard unit, no winter start 34 Standard unit with winter start on circuits no. 1 and 2 16 VAV VIOP, no winter start 9 VAV FIOP with winter start on circuits no. 1 and 2 NOTES (For Fig. 1-8) 10. Reset OPS before resetting thermostat. 11. The AFR is used only when 38AH is connected to a single air handler. Use airflow relay Carrier part no. HN61KK040, HN61KK060, or equivalent. 12. The following table lists information for replacement of CB3, CB4, and CB5. CB3 CB4 AND 5 Max Voltage Rating Mfg Part No. Potter & Brumfield Must- Trip Amps Max Voltage Rating Mfg Part No. Potter & Brumfield Must- Trip Amps 250-v W28X v W2BX
3 NOTES (cont) 13. The motor-compressor is a thermally protected system. Circuit breaker must-trip amps are less than or equal to 156% RLA. 60 Hz UNITS The following tables list compressor and fan circuit breaker data. UNIT SIZE 38AH MAIN VOLTAGE / / / UNIT SIZE 38AH MAIN VOLTAGE / / / CONTROL VOLTAGE CONTROL VOLTAGE Heinemann 50 Hz UNITS COMP CB1 AND 2 Airpax MUST-TRIP AMPS CB CB CF3-Z CF3-Z CF3-Z CF3-Z CB1 CF3-Z CB2 CF3-Z CB1 CF3-Z CB2 CF3-Z CB1 CF3-Z CB2 CF3-Z CF3-Z CF3-Z CF3-Z CF3-Z Heinemann COMP CB1 AND 2 Airpax MUST-TRIP AMPS CB CB CF3-Z CF3-Z CB1 CF3-Z CB2 CF3-Z CF3-Z CF3-Z CB1 CF3-Z CB2 CF3-Z
4 OPERATING SEQUENCE Standard Constant Volume Unit with 2-Stage Cooling Thermostat Seven seconds after a thermostat call for the first stage of cooling, compressor no. 1 and the outdoor fans start. The no. 2 fan only starts if the outdoor ambient temperature is above 70 F (21.1 C). The oil-pressure switch and the low-pressure switch are bypassed for 1 and 2 1 / 2 minutes, respectively. If either the low-pressure switch or oil pressure switch remain open after the delay, the unit shuts down and goes into alarm mode. The indoor-fan motor starts immediately whenever there is a call for cooling. If a liquid line solenoid valve has been installed (for refrigerant control during the off cycle), then the solenoid valve for compressor no. 1 opens immediately upon a call for cooling. On standard units, compressor no. 1 operates either fully loaded or at one step of unloading, depending on the suction pressure, which is dependent on the evaporator load conditions. As the cooling demand increases, the thermostat calls for the second stage of cooling. Within 7 seconds from a call for the second stage of cooling, compressor no. 2 starts. The oil switch and low-pressure switch for circuit no. 2 are bypassed during start-up. As the cooling load is satisfied, the thermostat stops the call for the second stage of cooling, which in turn deenergizes compressor no. 2, closes the no. 2 liquid line solenoid (if installed) and energizes the compressor no. 2 crankcase heater. If the space temperature continues to decrease, then the thermostat stops the call for the first stage of cooling, which then deenergizes compressor no. 1 and the outdoor fans, closes the no. 1 liquid line solenoid valve (if installed), and energizes the compressor no. 1 crankcase heater. The unit controls prevent both compressors from reenergizing within 3 minutes from a previous call for operation. If the unit safeties trip during operation, refer to the Installation Instructions shipped with the unit. To reset the lockout mode, cycle the unit power. NOTE: If the thermostat fan switch is in the auto position, the indoor fan cycles on and off as the thermostat calls for cooling (or heating). If the switch is in the continuous position, the fan runs when the outdoor unit is powered. Optional Variable Air Volume Unit with Modu- Panel Control The ModuPanel control regulates up to 10 stages of cooling to maintain a leaving-air temperature for variable air volume (VAV) applications. When connected to one 38AH condensing unit, only 6 stages are used. See Table 1 for unit loading and compressor operating sequence. When the timeclock connected to the panel closes, the indoor-fan contactor is energized through a field-supplied relay. (The relay must be a pilot-duty SPST relay with -v coil and 30 va maximum coil draw.) After the time delays programmed into the ModuPanel control have elapsed, and with the leaving air above the set point, the stages of mechanical cooling are sequenced as follows: 1. Stage 1 starts compressor no. 1 with 2 banks of cylinders unloaded ( 1 / 3 loaded). Both unloader solenoids are energized. 2. Stage 2 loads one bank of compressor no. 1 cylinders ( 2 / 3 loaded) by deenergizing unloader solenoid no Stage 3 loads the second bank of compressor no. 1 by deenergizing unloader solenoid no Stage 4 starts compressor no. 2 and unloads 2 banks of compressor no. 1 cylinders unloaded ( 1 / 3 loaded). Both unloader solenoids are energized. 5. Stage 5 loads one bank of compressor no. 1 cylinders ( 2 / 3 loaded) by deenergizing unloader solenoid no Stage 6 loads one bank of compressor no. 1 cylinders (fully loaded) by deenergizing unloader solenoid no. 2. Two Optional Variable Air Volume Units with a Single ModuPanel Control The ModuPanel control regulates up to 10 stages of cooling to maintain a leavingair temperature for variable air volume (VAV) applications. When connected to two 38AH condensing units, all 10 stages are used. See Table 2 for unit loading and compressor operating sequence. When the timeclock connected to the panel closes, the indoor-fan contactor is energized through a field-supplied relay. (The relay must be a pilot-duty SPST relay with -v coil and 30 va maximum coil draw.) After the time delays programmed into the ModuPanel control have elapsed, and with the leaving air above the set point, the stages of mechanical cooling are sequenced as follows: 1. Stage 1 starts unit no. 1 compressor no. 1 with 2 banks of cylinders unloaded ( 1 / 3 loaded). Both unloader solenoids are energized. 2. Stage 2 loads one bank of unit no. 1 compressor no. 1 cylinders ( 2 / 3 loaded) by deenergizing unloader solenoid no Stage 3 turns off unit no. 1 compressor no. 1 and starts compressor no. 2 fully loaded. 4. Stage 4 starts unit no. 1 compressor no. 1 with 2 banks of cylinders unloaded ( 1 / 3 loaded). Both unloader solenoids are energized. 5. Stage 5 loads one bank of unit no. 1 compressor no. 1 cylinders ( 2 / 3 loaded) by deenergizing unloader solenoid no Stage 6 loads one bank of unit no. 1 compressor no. 1 cylinders (fully loaded) by deenergizing unloader solenoid no Stage 7 starts unit no. 2 compressor no. 1 with 2 banks of cylinders unloaded ( 1 / 3 loaded). Both unloader solenoids are energized. 8. Stage 8 turns off unit no. 2 compressor no. 1 and starts compressor no. 2 fully loaded. 9. Stage 9 starts unit no. 2 compressor no. 1 with 2 banks of cylinders unloaded ( 1 / 3 loaded). Both unloader solenoids are energized. 10. Stage 10 loads 2 banks of unit no. 2 compressor no. 1 cylinders (fully loaded) by deenergizing both unloader solenoids. Restart Manual reset of the -v control circuit is required if unit is shut down by any of the safety devices. Applicable devices include the high-pressure switch (HPS), lowpressure switch (LPS), oil-pressure switch (OPS), and compressor overtemperature protection (COTP) switch. To restart the unit after the unit has been shut down, raise the thermostat set point above the space temperature (thereby removing the call for cooling) and then lower the set point back to the desired setting. If unit circuit breakers trip during unit shutdown, they must be reset manually. Causes of Complete Unit Shutdown: interruption of supplied power open compressor overtemperature protection (COTP) compressor electrical overload protection (CB1 or CB2) open high-pressure or low-pressure safety switches open oil pressure switch 4
5 Table 1 Unit Loading Sequence with ModuPanel Control STAGE NO. CYLINDERS LOADED CYLINDERS Compressor No. 1 Compressor No. 2 CAPACITY STEP (%) Table 2 Loading Sequence, Two Condensing Units with ModuPanel Control UNIT 1 LOADED CYLINDERS UNIT 2 LOADED CYLINDERS STAGE NO. CYLINDERS Compressor No. 1 Compressor No. 2 Compressor No. 1 Compressor No. 2 CAPACITY STEP (%)
6 a eps Fig. 1 Component Arrangement, 38AH0-034, 208/-3-60 and Units 6
7 a Fig. 2 Power Schematic, 38AH0-034, 208/-3-60 and Units 7
8 a Fig. 3 Component Arrangement, 38AH0-034, Units 8
9 a Fig. 4 Power Schematic, 38AH0-034, Units 9
10 Fig. 5 Component Arrangement, 38AH0-034, Units a
11 a Fig. 6 Power Schematic, 38AH0-034, Units 11
12 a Fig. 7 Component Arrangement, 38AH0-034, -3-50, 380/ and Units 12
13 a Fig. 8 Power Schematic, 38AH0-034, -3-50, 380/ and Units 13
14 *Use thermostat wiring shown here for single air-handler applications. CB3 protects control circuit at the following unit voltages: CONTROL CIRCUIT PROTECTED AT: (V-Ph-Hz) UNIT (V-Ph-Hz) 208/ NOTES: 1. CB4 protects TB2 circuit; CB3 protects TB3 circuits. 2. LLSV1 and LLSV2 are field supplied. 3. On 208/, 460, and units, TB2 is -v and TB3 is -v. On and, 346, and units, TB2 is -v and TB3 is -v. **For a single air handler, LLSV valve 1 is to be used on the lower (no. 1) evaporator circuit. The LLSV valve 2 is to be used on the upper (no. 2) evaporator circuit. Only one indoor-fan contactor is required on single air-handler applications. Use Carrier accessory part no. 40RR for indoor-fan contactor. Fig. 9 Unit 38AH with Two-Stage Thermostat a eps 14
15 C SEE MODUPANEL ACCESSORY INSTALLATION FOR SCHEMATIC NOTES: 1. Factory wiring is in accordance with National Electrical Code (NEC). Field modifications or additions must be in compliance with all applicable codes. 2. Wiring for field power supply must be rated 75 C minimum. Use copper, copper-clad aluminum or aluminum conductors. Maximum incoming wire size for main terminal block (TB1) is 350 maximum kcmil ( v). All other voltages 2/0 maximum. 3. Terminal blocks TB2 and TB3 are for external field control connections. Control connections are to be Class 2 wiring. 4. Field supplied components (IFC, LLS-1 and LLS-2) must have a maximum sealed coil rating of 30 va (.25 amps at 120 vac,.13 amps at 120 vac). Thermostats must have a pilot duty rating of 120 va, (1 amp at 120 vac,.52 amp at vac). The fan switch must have a pilot duty rating of 30 va (.25 amp at 120 vac,.13 amp at vac). The AFS must have a pilot duty rating of 30 va (1.25 amps at vac). 5. Replacement of factory wires must be with type 105 C wire or its equivalent. 6. Field-supplied liquid line solenoid valves installed at the evaporator are required on Circuits 1 and 2 on all units. 7. TRAN1 has 75 va available for field-installed accessories. 8. ModuPanel control is wired for one air handler only. Fig. 10 One 38AH Dual-Circuit Condensing Unit with ModuPanel Control a
16 NOTES: 1. Factory wiring is in accordance with National Electrical Code (NEC). Field modifications or additions must be in compliance with all applicable codes. 2. Wiring for field power supply must be rated 75 C minimum. Use copper, copper-clad aluminum or aluminum conductors. Maximum incoming wire size for main terminal block (TB1) is 350 kcmil ( v). All other voltages 2/0 maximum. 3. Terminal blocks TB2 and TB3 are for external field control connections. Control connections are to be Class 2 wiring. 4. Field supplied components connected to TB3 (e.g., LLSV1 and LLSV2) cannot exceed 75 va total inductive load at vac, so that TRAN1 does not become overloaded. The air handler auxiliary motor starter contacts must have a minimum contact rating of 30 va at vac. The airflow switch must have a minimum contact rating of 125 va at vac. 5. Replacement of factory wires must be with type 105 C wire or its equivalent. 6. Field supplied liquid line solenoid valves installed at the evaporator are required on Circuits 1 and 2 on all units. 7. TRAN1 has 75 va available for field-installed accessories. 8. ModuPanel is wired for one air handler only. 9. AFR only used with single air handler. Use HN61KK040,060 or equivalent. 10. For MPR, use HN61KK040,060 or equivalent. MPR MPR SEE MODUPANEL ACCESSORY INSTALLATION FOR SCHEMATIC SEE MODUPANEL ACCESSORY INSTALLATION FOR SCHEMATIC Fig. 11 Two 38AH Dual-Circuit Condensing Units with ModuPanel Control Copyright 2009 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No Printed in U.S.A. Form 38AH-9W Pg Replaces: 38AH-8W
Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz
Wiring Diagrams 38ARZ007-012 38ARS008-012 38ARD012-024 Air-Cooled Condensing Units 50/60 Hz UNIT 38AR DIAGRAM INDEX VOLTAGE-PHASE-HERTZ LABEL DIAGRAM FIGURE NO. 208/230-3-60 38AK540117 1 or 2* 400/460-3-50/60
More informationwiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX
wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT Cancels: New 569C Sizes 072 to 120 576B Sizes 090-120 575A Size 090 WD 569C.72.4 8/15/02 UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM
More informationWiring Diagrams DIAGRAM INDEX
50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component
More informationAIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.
wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC
More informationSINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES
wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component
More informationWiring Diagrams DIAGRAM INDEX 208/230PW,XL;380PW;380/415PW;460PW;575PW XL;380/415XL;460XL;575XL ,070
30GTN,GTR040-420 30GUN,GUR040-420 ComfortLink Reciprocating Liquid Chillers 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GTN,GTR,GUN,GUR Voltage Figure Label Diagram Number No. 30GT-
More informationWiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6
9AB4-12 Air-ooled Remote ondenser Wiring Diagrams INDEX UNIT 9AB DRAWING TYPE DRAWING NUMBER FIG. NO. 4,6 Label Diagram 9AB6-10816 1 8,12 Label Diagram 9AB12-10816 2 AESSORIES OMPONENT PART NO. FIG. NO.
More informationInstallation Instructions
30GTN015-035 Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION.................................1-11
More informationProduct Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons
Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who
More informationDTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5
Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationInstallation, Operation, and Troubleshooting Instructions
Installation, Operation, and Troubleshooting Instructions 48/50HJ004-024 48/50TJ004-028 Apollo Control GENERAL The Apollo control is a relay pack which is factory wired and mounted in the Carrier rooftop
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationWiring Diagrams. NOTE: This literature applies to units produced after 11/3/96 (software version 2.0 or greater) DIAGRAM INDEX
48/50EJ,EK,EW,EY024-068 50EJQ,EWQ024,028 Gas Heating/Electric Cooling Electric Cooling and Heat Pump Units (50/60 Hz) Wiring Diagrams NOTE: This literature applies to units produced after 11/3/96 (software
More informationProduct Data. Features/Benefits. 40QA Cooling Only and Heat Pump Ceiling Suspended Fan Coil. 1 1 / 2 to 5 Nominal Tons
Product Data 40QA Cooling Only and Heat Pump Ceiling Suspended Fan Coil 1 1 / 2 to 5 Nominal Tons The 40QA Energy-Efficient Ceiling Suspended fan coil incorporates innovative technology to provide reliable
More informationProduct Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving
Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet
More informationInstallation, Start-Up and Service Instructions
Installation, Start-Up and Service Instructions GEMINI 38ARZ007-012, 38ARS008-012 38ARD012-024, 38AKS014-024 Air-Cooled Condensing Units 50/60 Hz CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...
More informationInstallation, Start-Up and Service Instructions
Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...1-9 Step 1 Complete Pre-Installation Checks...1 UNPACK UNIT INSPECT SHIPMENT Step 2 Select Location...1
More informationProduct Data. Features/Benefits. 38ARZ ARS012 38ARD AKS with 40RM Commercial Air-Cooled Split Systems 50 Hz
Product Data 38ARZ007-012 38ARS012 38ARD012-024 38AKS014-024 with 007-028 Commercial Air-Cooled Split Systems 50 Hz 19.0 to 64.3 kw (5.3 to 20 Tons) 38AKS014-024 38ARD024 Copyright 2004 Carrier Corporation
More informationInstallation, Start-Up and Service Instructions
Installation, Start-Up and Service Instructions 38HDF018-036 Duct Free Condensing Units 38HDR018-060 Ducted Condensing Units CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION... 1-10 Step 1 Complete
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationE1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams
E1 Electrical Fundamentals # 4 - Symbols and Wiring Diagrams Loads Electrical Loads onsume electricity Do work Examples: Motors Solenoids Heaters Lights 2005 Refrigeration Training Services - E1#4 Symbols
More informationProduct Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )
(N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS
More informationMODEL MW200 MODEL MW600 AIR DRYER
OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0
More informationProduct Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons
Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationAVPTC. Air Handlers 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion
More informationProduct Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.
Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing
More informationInstallation Instructions
CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...
More informationProduct Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving
Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationGENERAL ELECTRIC VERTICAL PACKAGED UNITS
GENERAL ELECTRIC VERTICAL PACKAGED UNITS APF Series APF036 thru APF060 3 TR thru 5 TR 10 kw thru 17.5 kw GE_APF_Series.indd 1 CONTENTS Model decoding 3 Unit features 4-5 General data 6 Cooling capacities
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features
Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...
More informationAVPTC Multi-Position, Internal Txv
Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration
More informationUser s Information and Installation Instructions
Outdoor Air Conditioner User s Information and Installation Instructions 13 SEER R-410A High Efficiency Split System These units have been designed and tested for capacity & efficiency in accordance with
More information1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.
WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationInstallation, Start-Up and Service Instructions
GEMINI 38AQ007 38ARQ008,012 38AQS016 Split System Heat Pumps 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION... 1-17 General...1 Step 1 Complete
More informationAllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax
AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The
More informationInstallation Instructions
50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,
More informationProduct Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving
Product Data ROOMTOP 50AH024-096 Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE 90.1 certification
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationOPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES
OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL 500644 FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES A047-001 FIGURE 1: Demand Defrost Control Module ANTI-SHORT CYCLE DELAY
More informationTECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS
TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM
More informationDANFOSS OPTYMA PLUS INVERTER UNITS
Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a
More informationSAFETY CONSIDERATIONS
Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...1-9 Step 1 Complete Pre-Installation Checks..1 UNCRATE UNIT INSPECT SHIPMENT CONSIDER SYSTEM REQUIREMENTS
More informationThe Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant
The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design
More informationENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL
ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance
More informationMR3CCUHV Temperature/Defrost Control
Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature
More informationWJH4 Product Specifications
UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate
More informationI/O ZONE 560/583 AND OPERATION MANUAL
UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationCommercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section
COMMERCIAL SERIES Commercial Series Commercial Series Power switch & Nameplate location: NAMEPLATE: Single and Dual Section Must reach over behind Front Panel to access: Single and Dual Section Commercial
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationInstallation, Start-Up and Service Instructions
38AKS028-044 Air-Cooled Condensing Units Installation, Start-Up and Service Instructions CONTENTS SAFETY CONSIDERATIONS....1 BEFORE INSTALLATION... 1-6 Placing Unit.. 1 Mounting Unit. 6 Compressor Mounting..
More informationWPH4 Product Specifications
Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationB24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT
SERVICE UNIT INFORMATION Corp. 9311 L2 B24 Litho U.S.A. The B24 blower units are designed for multi-position installation with add-on C22FC/CR22/CH22 or C24FC/ CR24/CH24 series coil sections. The B24 may
More informationAVPTC. Air Handler 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in
More informationInstallation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits Light Commercial Package A/C and Heat Pump Systems Description Installation of 208/240V and 480V H5HK 3 Phase Heater Kits in 6, 7.5 and
More informationCapacity: 1.5 to 6.0 Ton
VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System Hazardous Location N.E.C. and I.E.C. Approved 50 Hertz Models 60 Hertz, High Ambient, & Custom Designs Available
More informationPAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationUnity Board Micro Air Corporation Phone (609) Route Allentown NJ Fax (609)
Unity Board Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 January 11, 2016 1 Revision 1.02 Introduction The Unity board is a next generation
More informationCapacity: 1.5 to 6.0 Ton
VACPB1 Series Wall Mount Explosion Proof Air Conditioner and Room Pressurization System CSA Certified for Use in Division 2 Locations 60 Hertz Models 50 Hertz, High Ambient, & Custom Designs Available
More informationFLAKER/DCM SEQUENCE OF OPERATION
FLAKER/DCM SEQUENCE OF OPERATION H O S H I Z A K I A M E R I C A The Flaker and DCM series of ice machines use a completely different ice making process than the cuber style of icemaker. The Flaker has
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL SINGLE PACKAGED ROOF TOP AIR CONDITIONERS 'PT' SERIES MODELS: PT036 - PT360
INSTALLATION, OPERATION & MAINTENANCE MANUAL SINGLE PACKAGED ROOF TOP AIR CONDITIONERS 'PT' SERIES MODELS: PT036 - PT360 Part Number: 800-213-03 Contents General INDEX Page Model decoding... 2 General
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More information14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase
SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More informationLiebert CSU3000 Chiller
CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationDVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV
DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3
More informationProduct Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons
Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped
More informationINSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121
INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234
More informationUP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationInstallation Instructions
50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More informationDVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons
DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow
More informationASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...
More informationCondensing Units CUS 15-60
Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....
More informationOperator: Save these instructions for future use!
50A65-843 Universal Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
More informationMODELS B1PA024, 030 AND 036
STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat
More informationSECTION ROTARY-SCREW WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.
More informationAIR COOLED CONDENSING UNITS IMPORTANT DESIGN FEATURES
AIR COOLED CONDENSING UNITS The Model RCD air cooled condensing unit is a product of years of experience in the design, manufacture and application of heat transfer equipment. Thoroughly proven by thousands
More informationProduct Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:
AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS (018-060) Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationConstruction Electrical
INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationOPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER
OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This
More informationProduct Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz
Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION
More informationInstallation, Start -Up and Service Instructions
HEAT PUMP CONDENSING UNITS, 60 Hz WITH PURON R (R -410A) REFRIGERANT SIZES 16-25 Installation, Start -Up and Service Instructions CONTENTS SAFETY CONSIDERATIONS... 2 INSTALLATION GUIDELINES... 2 INSTALLATION...
More informationWiring Diagrams From 1296Gxxxxx From 1296Gxxxxx Motormaster I Control Wiring Details
8HJ00-0 Single Package Rooftop Gas Heating/Electric Cooling Units Wiring Diagrams UNIT WIRING DIAGRAMS Unit Volt-Ph-Hz Type From Label Fig. No. 8HJD/E/F00,005 08/0--60 Schematic/Component Arrangement 50HJ5008
More informationPLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual
Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it should
More information