G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

Size: px
Start display at page:

Download "G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2."

Transcription

1 P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL NUMBER IDENTIFICATION G 6 MP - 36 B Unit Type G = Gas Furnace Series 6 = 90% Minimum AFUE Configuration MP = Multi-Position Nominal Add-On Cooling Capacity 36 = 3 tons 48 = 4 tons 60 = 5 tons Cabinet Width B = 7-/ in. C = in. D = 4-/ in. Nominal Gas Heat Input 045 = 44,000 Btuh 070 = 66,000 Btuh 07 = 66,000 Btuh 090 = 88,000 Btuh 09 = 88,000 Btuh 0 = 0,000 Btuh = 0,000 Btuh 35 = 3,000 Btuh Indoor coils with the same letter designation will physically match the furnace.

2 FEATURES Contents Blower/Watts Data...6 Furnace/Coil Combined Dimensions... Dimensions...0 Exhaust Pipe Venting Table...8 Features... Filter Air Resistance...9 Gas Heat Accessories...7 Installation Clearances...9 Installation Configurations...9 Model Number Identification... Optional Accessories...7 Optional Accessory Dimensions... Specifications...6 Termination Kits - Equivalent Vent Lengths...8 WARRANTY Duralok Plus Aluminized Steel Heat Exchanger - Limited lifetime warranty in residential applications (twenty year transferrable), ten years in non-residential applications. All other covered components - Limited five year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units certified by CSA International and ratings are certified by GAMA. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Blower data from unit tests conducted in Lennox Laboratory air test chamber. Approved by the California Energy Commission and meet California Seasonal Efficiency requirements and California Nitrogen Oxides (NOx) Standards. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 900 Registered Manufacturing Quality System. APPLICATIONS Input capacities of 44,000, 66,000, 88,000, 0,000, and 3,000 Btuh. Energy efficiency (AFUE) of up to 95% in all four installation configurations. Compact cabinet for upflow, downflow, horizontal-left or horizontal-right applications without any internal modifications to the unit. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. G6MP / Page DIRECT VENT / NON-DIRECT VENT Furnace can be installed in either Direct Vent or Non-Direct applications. In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors. In Non-Direct Vent applications, combustion air is supplied from indoors and flue gases are discharged outdoors. OPTIONS Termination Kits Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. See Specifications table and dimension drawings. Termination Kit - Concentric - Direct Vent Applications Only or 3 inch kit contains concentric termination assembly, reducer bushing and 45 degree elbow. inch kit for models contains an outdoor exhaust accelerator. Kit requires single hole penetration of roof or wall for installation. Roof Termination Flashing Kit is available for use with inch Kits. CSA certified. M G K E F J Termination Kits - Wall Assembly A Close Couple (US Only) - Direct Vent Applications Only or 3 inch kit consists of close-couple, side-by-side PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. B D L H I C Piping spacing and length is sized for proper wall installations. CSA certified.

3 FEATURES B C Close Couple WTK (Canada Only) - Direct Vent Applications Only or 3 inch kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. Wall Ring - Direct or Non-Direct Vent inch kit contains stainless steel outside seal caps, galvanized steel inside seal caps, 4 seal rings for the caps and 8 inch insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches between the inlet and outlet openings in the installation of the pipes. Roof Termination Flashing Kit - Direct or Non-Direct Vent or 3 inch kit contains two neoprene rubber roof flashings for vertical venting through a roof. Vent pipe and insulation not furnished. Each kit contains enough parts for two non-direct vent installations. Also available for use with inch (use 3 inch flashing) Concentric Vent Termination Kits used in vertical venting rooftop applications. HEATING SYSTEM Lennox Duralok Plus Heat Exchanger Assembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main 3-pass clamshell type heat exchanger constructed of heavy-gauge, aluminized steel. Designed for normal expansion and contraction. Crimped seam design and construction provides maximum efficiency and minimum resistance to airflow. Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil. Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. All components mounted in a heavy-gauge steel frame. Heat exchanger assembly has been laboratory life cycle tested. Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate collars. Hose connects the header box drains to the condensate collars. The condensate collars are located on each side of the cabinet for easy field installation of condensate drain trap. Only one collar is used, the remainder stay plugged. Condensate drain trap is included with the unit for field installation. D E F G Lennox Designed Flue Condensate Trap Assembly Condensate trap assembly is mounted outside the conditioned air stream. Assembly can be mounted on either side of cabinet in upflow and downflow applications. Assembly is mounted on the bottom of the cabinet in horizontal applications. See Installation Instructions. Connection can be made with field provided / in. PVC pipe, 3/4 in. PVC coupling, or -/4 in. OD x in. ID tubing with hose clamp. Easy to clean and winterize. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. Two-Stage Gas Control Valve 4 volt redundant combination two stage gas control valve combines manual shut off valve (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Flame Rollout Switch Manual reset switches are factory installed on burner box. Switch provides protection from abnormal operating conditions. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Tungsten heater element sandwiched between two plates of silicon nitride. Cemented to steatite block for protection against current leakage. Ignition leads constructed of nickel plated copper enclosed in high temperature Teflon insulation for dependable operation. No electrical noise. Combustion Air Inducer PSC, heavy-duty blower prepurges heat exchanger and safely vents flue products. Pressure switches prove blower operation before allowing gas valve to open. Operates only during heating cycle. Limit Control Automatic reset, primary and secondary limits are accurately located. Primary limit factory installed on vestibule panel on all units, secondary limit factory installed on blower housing. G6MP / Page 3

4 FEATURES H I OPTIONS High Altitude Orifice Kit - Natural Gas Only Required for all natural gas models for proper unit operation at altitudes of 750 to 0,000 feet. Proper orifice for LPG/Propane models is included with LPG/Propane Conversion Kit. High Altitude Pressure Switch Kit Required on certain units for proper unit operation on installations above 4,500 ft. Order two per unit. LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. BLOWER Multi-speed, direct drive blower. Statically and dynamically balanced. Resiliently mounted. Blower assembly slides out of unit for servicing FILTER (NOT FURNISHED) Filter and provisions for external mounting must be field provided. OPTIONS Air Filter and Rack Kit for Horizontal Return Air (End) Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. Air Filter and Rack Kit for Side Return Air Applications (Not for use with RAB Return Air Base) Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. Available in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. EZ Filter Base for Bottom Return Air Applications Hinged door with thumbscrew for easy filter access. Uses standard size filters (field provided). J K L M CONTROLS SureLight Integrated Two-Stage Furnace Control Board Solid-state board contains all necessary controls and relays to operate furnace. Combustion air inducer is controlled by board. Prior to ignition, a pre-purge cycle for 5 seconds is initiated. After the main burners are turned off, a post-purge cycle for 5 seconds is run. Adaptive technology of ignition control board continuously monitors and adjusts the ignitor power to operate at minimum ignitor temperature required for ignition, prolonging ignitor life. Electronic flame sensor control assures safe, reliable operation. Should loss of flame occur, flame sensor controls will initiate 5 attempts at re-ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Jumper settings for single or two stage thermostat operation. Two selectable second stage recognition times (0 and 5 minutes) are available on the board when the furnace is used with a single-stage thermostat. When used with a two-stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Fan control consists of adjustable blower timed-off delay (60, 90, 0, 80 seconds - factory setting 90 seconds) and fixed blower timed-on delay (45 seconds). For air-conditioning applications, blower is automatically energized on thermostat demand for cooling. Adjustable blower timed-off delay in cooling mode ( or 45 seconds - factory setting 45 seconds). Terminal for continuous low speed blower operation. Two accessory terminals furnished for additional power supply requirements for 0 volt (less than amp) power humidifiers and powered air cleaners. 4 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. G6MP / Page 4

5 FEATURES N O P OPTIONS Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. CABINET -profile, narrow width cabinet allows easy installation in upflow, downflow or horizontal applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Tool-less latches on blower and burner doors assure positive lock. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Return Air Entry: For bottom/end return-air entry for upflow/horizontal applications, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or RAB is required when using an IAQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IAQ products higher than 0 in. require a field fabricated transition. See dimension drawings. NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air with transition, to accommodate 0 x 5 x in. cleanable air filter, required to maintain proper air velocity.. Single side return air with optional RAB Return Air Base. 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. Coil Match-up All furnaces exactly match C33 and CX34 cased upflow indoor coils and CH33 horizontal indoor coils with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. C33 uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See C33 coil bulletin for additional information. All furnaces exactly match CR33 cased, downflow indoor coils with adaptor rails, furnished with coil. OPTIONS Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6, 4 or 50 ft. lengths. Heat Cable Tape: 66 ft. length, / in. wide fiberglass. 60 ft. length, in. wide aluminum foil. Condensate Trap Alternate Location Kit Allows condensate drain to be installed on the opposite side of the furnace from the exhaust venting (upflow applications only). Downflow Additive Base Required for heating only units installed on combustible floors. Not required in add-on cooling applications. See Dimension Drawing. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of () x -/ x 3-5/8 in. and () x 3 x 53-7/8 in. painted, heavy-gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. RAB Return Air Base On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or RAB is required when using an IAQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IAQ products higher than 0 in. require a field fabricated transition. Must be used for 60C and 60D models with air volumes over 800 cfm in upflow applications when only one side return is required. Cabinet is pre-painted steel to match the furnace. See Dimension Drawing. G6MP / Page 5

6 SPECIFICATIONS Gas Model No. G6MP-36B-045 G6MP-36B-070 G6MP-36B-07 G6MP-48C-090 G6MP-60C-090 Heating High Input - Btuh 44,000 66,000 66,000 88,000 88,000 Performance Fire Output - Btuh 4,000 6,000 6,000 8,000 8,000 Temperature rise range - F Gas Manifold Pressure (in. w.g.) - Nat. Gas / LPG/Propane 3.5 / / / / / 0.0 Input - Btuh 30,000 45,000 45,000 60,000 60,000 Fire Output - Btuh 8,000 43,000 43,000 56,000 57,000 Temperature rise range - F Gas Manifold Pressure (in..7 / / / / / 4.9 w.g.) - Nat. Gas / LPG/Propane AFUE 94.% 94.% 95.0% 94.% 94.% High static Connections Intake / Exhaust Pipe (PVC) / / / / / in. Condensate Drain Trap / / / / / (PVC pipe) - i.d. with field supplied (PVC cplg.) 3/4 3/4 3/4 3/4 3/4 - o.d. hose with hose clamp - i.d. x o.d. x -/4 x -/4 x -/4 x -/4 x -/4 Gas pipe size IPS / / / / / Indoor Blower G6MP / Page 6 Wheel nom. dia. x width - in. 0 x 8 0 x 8 0 x 8 0 x 0 -/ x 0 Motor output - hp /3 /3 /3 / Tons of add-on cooling Air Volume Range - cfm Shipping Data lbs. - package Electrical characteristics 0 volts - 60 hertz - phase (less than amps) NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. SPECIFICATIONS Gas Model No. G6MP-60C-09 G6MP-48C-0 G6MP-60C-0 G6MP-60C- G6MP-60D-35 Heating High Input - Btuh 88,000 0,000 0,000 0,000 3,000 Performance Fire Output - Btuh 83,000 04,000 04,000 04,000 4,000 Temperature rise range - F Gas Manifold Pressure (in. w.g.) - Nat. Gas / LPG/Propane 3.5 / / / / / 0.0 Input - Btuh 60,000 75,000 75,000 75,000 90,000 Fire Output - Btuh 58,000 7,000 7,000 7,000 86,000 Temperature rise range - F Gas Manifold Pressure (in..7 / / / / / 4.9 w.g.) - Nat. Gas / LPG/Propane AFUE 95.0% 94.% 94.% 95.0% 94.% High static Connections Intake / Exhaust Pipe (PVC) / / / / 3 / 3 in. Condensate Drain Trap / / / / / (PVC pipe) - i.d. with field supplied (PVC cplg.) 3/4 3/4 3/4 3/4 3/4 - o.d. hose with hose clamp - i.d. x o.d. x -/4 x -/4 x -/4 x -/4 x -/4 Gas pipe size IPS / / / / / Indoor Blower Wheel nom. dia. x width - in. -/ x 0 0 x 0 -/ x 0 -/ x 0 -/ x 0 Motor output - hp / Tons of add-on cooling Air Volume Range - cfm Shipping Data lbs. - package Electrical characteristics 0 volts - 60 hertz - phase (less than amps) NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.

7 OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA FILTER KITS Air Filter and Rack Kit B Width Models C Width Models D Width Models Horizontal (end) Size of filter - in. 87L96-8 x 5 x 87L97-0 x 5 x 87L98-5 x 5 x Side Return Single 44J 44J 44J Ten Pack 66K63 66K63 66K63 Size of filter - in. 6 x 5 x 6 x 5 x 6 x 5 x EZ Filter Base Catalog No. - Ship. Wt. - lbs. 73P56-7 (3) 73P57-8 (4) 73P58-0 (5) CABINET ACCESSORIES Size of field provided filter - in. 6 x 5 x 0 x 5 x 4 x 4 x Downflow Additive Base M60 M6 M6 Horizontal Support Frame Kit 56J8 56J8 56J8 Return Air Base 98M60 98M58 98M59 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 6K68 6K68 6K68 4 ft. 6K69 6K69 6K69 50 ft. 6K70 6K70 6K70 Heat Cable Tape Fiberglass - / in. x 66 ft. 39G04 39G04 39G04 Aluminum foil - in. x 60 ft. 39G03 39G03 39G03 Condensate Trap Alternate Location Kit - Upflow Only 76M0 76M0 76M0 TERMINATION KITS - See Installation Instructions for specific venting information. Termination Kits Direct Vent Applications Only Termination Kits - Direct or Non-Direct Vent Concentric US - in. 7M80 69M in L46 60L46 Canada - in. 44W9 44W in W93 44W93 Wall - Close Couple US - in. G Wall - Close Couple WTK 3 in. 44J40 44J40 44J40 Canada - in. 30G in. 8J0 8J0 8J0 Roof in. 5F75 5F Wall Ring Kit in. 5F74 5F74 3 5F74 Roof Termination Flashing Kit - Direct or Non-Direct Vent - Contains two flashings Cleanable polyurethane frame type filter. Kit contains enough parts for two, non-direct vent installations. 3 Non-direct vent only. 44J4 44J4 44J4 GAS HEAT ACCESSORIES Input High Altitude Orifice Kit Natural Gas Only High Altitude Pressure Switch Kit ORDER TWO EACH LPG/Propane Kit LPG/Propane to Natural Gas Kit 750-0,000 ft ft ft ,000 ft ft ,000 ft ft ,000 ft W W48 44W50 44W49 44W W W M06 44W48 44W50 44W49 44W W M8 4W49 4W49 6W83 44W48 44W50 44W49 44W M W M 56M 44W48 44W50 44W49 44W W M8 6W85 6W85 6W86 44W48 44W50 44W49 44W M8-0 44W M 44W48 44W50 44W49 44W W5-47M8 56M 56M 56M3 44W48 44W50 44W49 44W M W M93 56M93 44W48 44W50 44W49 44W W5 High Altitude Orifice Kit is required and must be ordered separately for applications from 750 to 0,000 ft. G6MP / Page 7

8 EXHAUST PIPE VENTING TABLE (For altitudes of 0-0,000 ft) Vent Pipe Diameter G6MP-36B-045 G6MP-36B-070 G6MP-36B-07 Maximum Equivalent Vent Length - ft. G6MP-36C-090 G6MP48C-090 G6MP-60C-090 G6MP-60C-09 G6MP-60C-0 G6MP-60C- 3 G6MP-60D-35 in not not -/ in not 3 in ( ft.) 4 46 (450-0,000 ft.) 4 in NOTE - Minimum Equivalent Vent Pipe length is 5 feet (4.6 m). Maximum Equivalent Vent Length permitted is defined as Total Length (linear feet) of vent pipe, plus equivalent length (ft.) of fittings, plus equivalent length (ft.) of termination. 0 models installed in upflow or downflow applications must have the supplied 90 street ell installed directly into the unit flue collar. The street ell must be included in the elbow count models installed in upflow or downflow applications must have 3 in. to in. reducing elbow (supplied) installed directly into the flue collar. Reducing ell must be included in elbow count elbows must be limited to sweep type elbows. VENTING NOTES - One 90 elbow is equivalent to 5 feet of straight vent pipe. Two 45 elbows are equal to one 90 elbow. One 45 elbow is equivalent to.5 feet of straight vent pipe. Wall and roof termination (non-concentric) exhaust pipe must terminate with reducer to improve exhaust velocity away from intake piping. 045 and 070 -, -/, 3 or 4 in. - terminate with -/ in. pipe 090 -, -/, 3 or 4 in. - terminate with in. pipe 0 - -/, 3 or 4 in. - terminate with in. pipe 35-3 or 4 in. - terminate with in. pipe TERMINATION KITS - EQUIVALENT VENT LENGTHS Input Size Vent Pipe Diameter in. G6MP / Page 8 Concentric Kits Vent Pipe Equivalent Length - ft. Close Couple Kits Wall Ring Kit Outdoor Exhaust Accelerator (Diameter X Length) For use with Close Couple and Wall Ring Kits in. 3 in. in. 3 in. in. -/ x in. x in. 4 7M W9 69M9 60L46 44W93 G44 44J40 30G8 (WTK) 8J0 (WTK) 5F74 Field Provided -045 not not not -/ not not not -/ not not not -/ not not not -/ not 5 not not Requires field provided -/ in. outdoor exhaust accelerator. Requires field provided in. outdoor exhaust accelerator. 3 For use only in non-direct vent applications, when snow riser is not required. Requires field provided in. outdoor exhaust accelerator. 4 Outdoor exhaust accelerator is furnished in 7M80 and 44W9 kits and is required when used with models. The accelerator is not used with models.

9 INSTALLATION CONFIGURATIONS VENT PIPING UPFLOW FLOW DOWNFLOW HORIZONTAL RIGHT VENT PIPING HEAT EXCHANGER BLOWER BLOWER HEAT EXCHANGER FLOW VENT PIPING CONDENSATE DRAIN HORIZONTAL LEFT CONDENSATE DRAIN BLOWER HEAT EXCHANGER VENT PIPING FLOW CONDENSATE DRAIN NOTE On upflow and downflow configurations, the vent piping and condensate drain can be moved to the other side of the unit. Vent piping and drain must be installed on the same side of the unit with each other unless optional Condensate Trap Alternate Location Kit (upflow only) is used. On horizontal installations the drain must be located at the bottom and the vent piping at the top. FLOW HEAT EXCHANGER CONDENSATE DRAIN BLOWER FILTER RESISTANCE For Inch Cleanable Filter (Field Provided) cfm INSTALLATION CLEARANCES Sides Rear Top/Plenum Front Front (service/alcove) Floor 0 inches (0 mm) 0 inches (0 mm) inch (5 mm) 0 inches (0 mm) 4 inches (60 mm) Combustible NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z3.) or the National Standard of Canada CAN/CSA-B49. Natural Gas and Propane Installation Code. NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z3.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/ CSA-B49.. Allow proper clearances to accommodate condensate trap and vent pipe installation. Clearance for installation on combustible floor if optional additive base is installed between furnace and combustible floor. Not required in add-on cool ing applications if installed in accordance with local codes or National Fuel Gas Code ANSI-Z3. or CAN/CGA-49.,.. Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. G6MP / Page 9

10 DIMENSIONS - INCHES (MM) - UPFLOW POSITION SHOWN NOTE - 60C and 60D size units that require air volumes over 800 cfm (850 L/s) must have one of the following: a. Single side return air with transition, to accommodate 0 x 5 x in. (508 x 635 x 5 mm) air filter. Required to maintain proper air velocity. b. Single side return air with optional RAB Return Air Base c. Bottom return air. d. Return air from both sides. e. Bottom and one side return air. SUPPLY OPENING See Blower Performance Tables for additional information. Optional External Side Return Air Filter Kit (Upflow Only) is not for use with the optional RAB Return Air Base. A B 9/6 (4) OPTIONAL EXTERNAL SIDE RETURN FILTER KIT (Either Side) 5-/ (40) 6-/ (65) 3-3/4 (603) 5 (635) TOP VIEW 8-/ (74) 9-7/6 (494) 9/6 (4) OPTIONAL EXTERNAL SIDE RETURN FILTER KIT (Either Side) 40 (06) -5/8 (95) Right 9-3/4 (48) Left 6-/ (65) 4-/8 (03) 4-7/8 (4) Right -/4 (57) Left 6-3/4 (7) -/ (64) 3-/8 (79) COMBUSTION INTAKE (Either Side) EXHAUST OUTLET (Either Side) GAS PIPING INLET (Either Side) CONDENSATE TRAP CONNECTION (Either Side) ELECTRICAL INLET (Either Side) FLOW 4-3/4 (375) 6 (406) 8-3/4 (476) 4 (0) 3 (584) OPTIONAL RETURN CUTOUT (Either Side) Upflow Only 4 (356) -5/6 (49) 3/4 (9) C 3/4 (9) Bottom Return Air Opening FRONT VIEW 5/8 (6) 4-/4 (08) 3-/ (597) Bottom Return Air Opening SIDE VIEW Model No. A B C in. mm in. mm in. mm G6MP-36B-045 G6MP-36B / / G6MP-36B-07 G6MP-48C-090 G6MP-60C-090 G6MP-60C-09 G6MP-48C / / 495 G6MP-60C-0 G6MP-60C- G6MP-60D-35 4-/ 6 3-3/ G6MP / Page 0

11 DIMENSIONS INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION A 40 (06) Furnace Width B DOWNFLOW POSITION 40 (06) UPFLOW POSITION Uncased Cased (CX34 - cased only) Model No A B A B in. mm in. mm in. mm in. mm C33-8A -/ 38 5-/ / /4 64 CX34-9A-6F C33-9A 6-/ / / /4 64 C33-4A 6-/ / CX34-8/4A-6F CX34-8/4B-6F C33-4B CX34-8/4C-6F C33-4C 6-/ / / /8 368 CX34-5A-6F C33-5A 8-/ / / /4 49 CX34-5B-6F C33-5B 8-/ / / /8 49 CX34-30B-6F C33-30B CX34-30C-6F C33-30C 0-/ 5 60-/ / /4 467 CX34-30A-6F C33-30A 0-/ 5 60-/ CX34-3A-6F C33-3A -/ 57 6-/ 588 -/ /4 556 CX34-3B-6F C33-3B -/ 57 6-/ / /4 530 CX34-36A-6F C33-36A 4-/ 6 64-/ 638 -/ /8 578 CX34-36B-6F C33-36B 4-/ 6 64-/ 638-7/ /8 57 CX34-36C-6F C33-36C 4-/ 6 64-/ 638 -/ /4 556 CX34-38A-6F C33-38A 4-/ 6 64-/ 638 -/ /4 58 CX34-38B-6F C33-38B 4-/ 6 64-/ CX34-4B-6F C33-4B 4-/ 6 64-/ 638-7/ /8 57 CX34-43B-6F C33-43B 7-/ / 75 6-/ /4 683 CX34-43C-6F C33-43C 7-/ / / /4 670 C33-44C 4-/ 6 64-/ 638 -/ / 56 CX34-44/48B-6F C33-48B 4-/ 6 64-/ 638 -/ /8 578 CX34-44/48C-6F C33-48C 4-/ 6 64-/ 638 -/ / 56 CX34-49C-6F C33-49C 9-/ / / / 740 CX34-50/60C-6F C33-50/60C7-/ / / /4 645 Overall CX34-60D-6F C33-60D 5-/ / / /4 645 Height CX34-6C-6F C33-6C 3-/ / / /8 793 CX34-6D-6F C33-6D 9-/ / / /4 746 Coil Width HORIZONTAL B 40 (06) Coil Height DOWNFLOW POSITION Furnace Overall Model Coil Width Coil Height Width Height Number in. mm in. mm in. mm in. mm CR33-8A-F 7-/ / / /8 375 CR33-4A-F 7-/ / / /4 353 CR33-4B-F 7-/ / / /4 353 CR33-30/36A-F 7-/ / / /8 46 CR33-30/36B-F 7-/ / / /8 46 CR33-30/36C-F / /8 46 CR33-48B-F / CR33-48C-F CR33-50/60C-F 4-/ / /8 36 CR33-60D-F 4-/ 6 4-/ 6 3-5/ /8 36 A HORIZONTAL POSITION Model Number A B in. mm in. mm CH33-8A-F -/ / 56 CH33-4/30A-F CH33-36A-F CH33-36B-F CH33-36C-F CH33-44/48B-F CH33-50/60C-F CH33-4B-F CH33-48C-F CH33-60D-F 6-/ / 689 CH33-6D-F 3-/ / 86 G6MP / Page

12 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) RAB RETURN BASE (Upflow Applications Only) For use with B, C, and D size furnaces only 4 (0) FLOW 4 (356) 7 /4 (84) CONDENSATE TRAP FURNACE FRONT 4 (356) 4 (0) 3 (584) Overall (Maximum) Unit side return air Opening 5 5/8 (43) SIDE RETURN OPENINGS (Either Side) Minimum (79) Maximum 4 (356) 0 / (5) Overall (Maximum) 7 / (446) RAB B (98M60) (533) RAB C (98M58) 4 / (6) RAB D (98M59) OPTIONAL RAB RETURN BASE 7/8 () 3 (584) 7 5/8 (70) SIDE VIEW FRONT VIEW Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): 3 x in. (584 x 79 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. 4 inches (356 mm) is the maximum size the height of the unit opening can be cut. This may interfere with the condensate drain (if located on the same side of the unit as the opening). To minimize pressure drop, the largest opening height possible (up to 4 inches) is preferred. NOTE Optional Side Return Air Filter Kits are not for use with RAB Return Air Base. DOWNFLOW COMBUSTIBLE FLOORING BASE -/ (38) 3/4 (9) SUPPLY OPENING DOWN FLOW FURNACE -/ (38) B 9-3/6 (503) -/ (38) 7-/4 (69) -3/6 (554) Front Of Furnace A -/ (38) TOP VIEW SIDE VIEW G6MP / Page (559) C DOWNFLOW COMBUSTIBLE FLOORING BASE FLOOR OPENING Model No. G6MP-36B-045 G6MP-36B-070 G6MP-36B-07 G6MP-48C-090 G6MP-60C-090 G6MP-60C-09 G6MP-48C-0 G6MP-60C-0 G6MP-60C- A B C in. mm in. mm in. mm 9-9/ / / / /6 50 -/4 565 G6MP-60D / / /4 654

13 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL FILTER KIT 4 3/4 (69) 5/8 (6) -/4 (3) A 5/8 (6) 5/8 (6) B RETURN OPENING 3 / (597) SIDE VIEW 5/8 (6) FLOW FILTER (Furnished) FRONT VIEW Catalog A B Number inch mm inch mm 87L / L / L /4 603 CONCENTRIC WALL TERMINATION APPLICATIONS CONCENTRIC ROOF TERMINATION APPLICATIONS EXHAUST OUTSIDE WALL INTAKE EXHAUST (305) Minimum Above Average Snow Accumulation FLASHING (Not Furnished) INTAKE CLAMP (Not Furnished) INTAKE (305) Minimum Above Grade or Average Snow Accumulation CLAMP SHEET METAL STRAP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) GRADE ELBOW (Field Supplied) A 3 / (89) in. kits 4 / (4) 3 in. kits 7M80 / 69M9 / 44W9 inch kits 60L46 / 44W93 3 inch kits See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. TERMINATION ASSEMBLY (Furnished) 6 / (65) INTAKE 6 (5) EXHAUST Outdoor Exhaust Accelerator included with 7M80/44W9 Cat. No. 7M80 69M9 44W9 (Canada) A B in. mm in. mm 33 3/ / / L / / W93 (Canada) 36 / / 495 NOTE Typical illustration for dimensions only. Design may vary depending on kit ordered. G6MP / Page 3

14 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) WALL ASSEMBLY TERMINATION KIT RING KIT 5F74 inch (5 mm) See Installation Instructions for specific usage. DIRECT VENT APPLICATION NOTE in. (305 mm) minimum height above average snow accumulation. NON DIRECT VENT APPLICATION Kit Contains Enough Parts For Two Installations average snow accumulation. in. (305 mm) maximum without support in. (305 mm) maximum without support 8 in. (03 mm) minimum 6 in. (5 mm) maximum If Intake and Exhaust Pipe is less than in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) G44 (US), 30G8 (WTK Canada) 3 inch (76 mm) 44J40 (US), 8J0 (WTK Canada) See Installation Instructions for additional information. *WALL SUPPORT INTAKE 6 (5) Maximum (305) MAX. for (5) Dia. Exhaust 0 (508) MAX. for 3 (76) Dia. Exhaust 6 (5) Minimum EXHAUST INTAKE 5 (7) (305) / (3) FOAM INSULATION (Field Furnished) EXHAUST (305) MAX. for (5) Dia. Exhaust 0 (508) MAX. for 3 (76) Dia. Exhaust (305) Minimum Above Grade or Average Snow Accumulation GRADE 5-/ (40) (305) Minimum Above Grade or Average Snow Accumulation GRADE G6MP / Page 4

15 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) (305) DIRECT VENT APPLICATIONS WTK WALL ASSEMBLY TERMINATION KIT (CANADA ONLY) WITH FIELD FABRICATION ABOVE GRADE EXTENDED CLEARANCE 30G8 inch (5 mm) 8J0 3 inch (76 mm) See Installation Instructions for additional information. If Intake and Exhaust Pipe is less than in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. EXHAUST INTAKE EXHAUST INSULATION (Not Furnished) INTAKE 5 (7) 5-/ (40) GRADE 8 (03) Minimum (305) Minimum Above Grade or Average Snow Accumulation GRADE in. (305 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - 3 in. (76 mm) dia. exhaust pipe maximum length without support G6MP / Page 5

16 BLOWER/WATTS DATA G6MP-36B-045 PERFORMANCE (Less Filter) External Static Pressure Air Volume / Watts at Different Blower Speeds High Medium- High Medium- cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). Air volume based on bottom air return air. Actual air volume may vary on side return air applications G6MP-36B-07 PERFORMANCE (Less Filter) External Static Pressure Air Volume / Watts at Different Blower Speeds High Medium- High Medium- cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). Air volume based on bottom air return air. Actual air volume may vary on side return air applications G6MP-36B-070 PERFORMANCE (Less Filter) External Static Pressure Air Volume / Watts at Different Blower Speeds High Medium- High Medium- cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). Air volume based on bottom air return air. Actual air volume may vary on side return air applications G6MP-48C-090 PERFORMANCE (Less Filter) External Static Pressure Air Volume / Watts at Different Blower Speeds High Medium- High Medium- cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). Air volume based on bottom air return air. Actual air volume may vary on side return air applications G6MP-48C-0 PERFORMANCE (Less Filter) External Static Pressure G6MP / Page 6 Air Volume / Watts at Different Blower Speeds High Medium- High Medium- cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). Air volume based on bottom air return air. Actual air volume may vary on side return air applications

17 BLOWER/WATTS DATA G6MP-60C-090 PERFORMANCE (Less Filter) External Static Pressure Bottom Return Air, Side Return Air with Optional RAB Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. Air Volume / Watts at Different Blower Speeds Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 0 x 5 x in. air filter in order to maintain proper air velocity. High Medium-High Medium- High Medium-High Medium- cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). G6MP-60C-09 PERFORMANCE (Less Filter) External Static Pressure Bottom Return Air, Side Return Air with Optional RAB Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. Air Volume / Watts at Different Blower Speeds Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 0 x 5 x in. air filter in order to maintain proper air velocity. High Medium-High Medium- High Medium-High Medium- cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). G6MP-60C-0 PERFORMANCE (Less Filter) External Static Pressure Bottom Return Air, Side Return Air with Optional RAB Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. Air Volume / Watts at Different Blower Speeds Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 0 x 5 x in. air filter in order to maintain proper air velocity. High Medium-High Medium- High Medium-High Medium- cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). G6MP / Page 7

18 BLOWER/WATTS DATA G6MP-60C- PERFORMANCE (Less Filter) External Static Pressure Bottom Return Air, Side Return Air with Optional RAB Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. Air Volume / Watts at Different Blower Speeds Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 0 x 5 x in. air filter in order to maintain proper air velocity. High Medium-High Medium- High Medium-High Medium- cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). G6MP-60D-35 PERFORMANCE (Less Filter) External Static Pressure Bottom Return Air, Side Return Air with Optional RAB Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. Air Volume / Watts at Different Blower Speeds Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 0 x 5 x in. air filter in order to maintain proper air velocity. High Medium-High Medium- High Medium-High Medium- cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts NOTES - All air data is measured external to unit without filter (not furnished - field provided). G6MP / Page 8

19

20 REVISIONS Document Added specifications, ratings and dimensions for 95% AFUE models (G6MP-36B-07, G6MP-60C-09, G6MP-60C-) Visit us at For the latest technical information, Contact us at LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 009 Lennox Industries, Inc.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2. G A S F U R N A C E S G61MP ELITE SERIES Multi Position Two Stage Heat E N G I N E E R I N G D A T A Bulletin No. 210382 September 2006 Supersedes August 2006 AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML95DF MERIT SERIES Downflow Bulletin No. 06 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION AFUE - 95% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICATIONS GAS FURNACES ML95UH MERIT SERIES Upflow / Horizontal Bulletin No. 059 March 08 Supersedes February 08 AFUE - 95% Input - 44,000 to,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL95UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 065 March 08 Supersedes February 08 AFUE - 95% Input - 0,000 to,000 Btuh Nominal

More information

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

DuralokPlus Aluminized Steel Heat Exchanger G 32 V ENGINEERING DATA GAS FURNACES G32V DAVE LENNOX SIGNATURE COLLECTION Up Flow Two Stage Heat Variable Speed Blower AFUE up to 94.2% Input 75,000 to 125,000 Btuh (22.0 to 36.6 kw) Add on Cooling 2 to 5 Tons

More information

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S SL280DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 20576 December 200 Supersedes July 200

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML9DF MERIT SERIES Downflow Bulletin No. 0589 March 09 Supersedes September 08 AFUE - 9% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL NUMBER

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal G S F U R N C E S G40UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D T Bulletin No. 210278 December 2008 Supersedes May 2007 FUE 80% Input 44,000 to 154,000 Btuh Nominal dd on Cooling 1.5

More information

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B E N G I N E E R I N G D T G S F U R N C E S ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 June 20 Supersedes May 20 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

ML 1 80 UH 070 X E 36 B

ML 1 80 UH 070 X E 36 B PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 2063 ugust 202 Supersedes January 202 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 February 208 Supersedes November 207 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

ML 1 93 UH 070 x P 36 B

ML 1 93 UH 070 x P 36 B PRODUCT SPECIFICTIONS GS FURNCES ML93UH MERIT SERIES Upflow / Horizontal Bulletin No. 20588 October 202 Supersedes ugust 202 FUE - 93% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

GSR21Q PULSE21 SERIES

GSR21Q PULSE21 SERIES GSR21Q PULSE21 SERIES ENGINEERING DATA HORIZONTAL/DOWN-FLOW GAS FURNACES HORIZONTAL UNIT HEATERS AND DOWN-FLOW MOBILE HOME UNITS *91.7% to 95.3% A.F.U.E. 50,000 to 100,000 Btuh (14.7 to 29.3 kw) Input

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SLP98UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower Bulletin No. 20577 March 208 Supersedes February 208 MODEL

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICTIONS GS FURNCES EL80UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 20660 February 208 Supersedes January 208 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SL80DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 060 November 07 Supersedes August 05 MODEL NUMBER IDENTIFICATION SL

More information

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

ELITE SERIES Upflow / Horizontal - Two-Stage Heat PRODUCT SPECIFICTIONS GS FURNCES EL280UH ELITE SERIES Upflow / Horizontal - Two-Stage Heat ulletin No. 2063 June 205 Supersedes January 205 FUE - 80% Input - 66,000 to 32,000 tuh Nominal dd-on Cooling

More information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17. PRODUCT SPECIFICTIONS GS FURNCES ML80UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ ulletin Number 49060 June 205 Supersedes June 203 Net Input - 7.4 to 34.8 kw Nominal dd-on Cooling - 0.6 to 7.6 kw MODEL

More information

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0307 L5 Revised 11 2006 G51MP SERIES UNITS G51MP G51MP series units are high efficiency multiple position (upflow, downflow, horizontal left and horizontal right) gas furnaces

More information

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SL80UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Blower Bulletin No. 0600 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION ENGINEERING DATA GSR21Q PULSE21 SERIES HORIZONTAL/DOWN-FLO GAS FURNACES HORIZONTAL UNIT HEATERS AND DOWN-FLO MOBILE HOME UNITS *91.7% to 95.3% A.F.U.E. 50,000 to 100,000 Btuh Input Add-On Cooling 1-1/2

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120 P R O D U C T S P E C I F I C AT I O N S O I L F U R N A C E S OHR23 ELITE SERIES Horizontal/Downflow ulletin No. 20097 February 20 Supersedes October 200 AFUE - Up to 83.5% Input - 05,000 to 54,000 tuh

More information

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower PRODUCT SPECIFICATIONS OIL FURNACES sl085bv DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower Bulletin No. 0677 August 05 Supersedes September 04 AFUE - Up to 87% Heating Input - 79,000 to

More information

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency lower Motor ulletin No. 20825 July 208 Supersedes February 208 FUE - 80% Input - 44,000 to 32,000 tuh Nominal

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML9UH MERIT SERIES Upflow / Horizontal Bulletin No. 0588 May 05 Supersedes January 05 FUE - 9% Input - 44,000 to,000 Btuh Nominal dd-on Cooling - to 5 Tons MODEL NUMBER

More information

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at   For the latest technical information, ENGINEERING DT Duralok Plus luminized Steel Heat Exchanger Pressure es Factory installed Field Wiring Make Up Box can be installed on either side Tool Less Entry Sight Glass Terminals for ccessory Connections

More information

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications ENGINEERING DATA Hot Copper Tube Coil WATER HEATING SPACE HEATING/WATER HEATING SYSTEM CAE 90.0% Space Heating Input 40,000 to 120,000 Btuh (11.7 to 35.2 kw) Heating Input 85,000 to 150, 000 Btuh (24.9

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML9UH MERIT SERIES Upflow / Horizontal Bulletin No. 0588 March 08 Supersedes February 08 FUE - 9% Input - 44,000 to,000 Btuh Nominal dd-on Cooling - to 5 Tons MODEL NUMBER

More information

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES EL96DFV ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower Bulletin No. 060 March 09 Supersedes September 08 MODEL NUMBER IDENTIFICATION EL 96 DF 070

More information

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents Service Literature Corp. 0303 L2 Revised 10 2004 G41UF SERIES UNITS G41UF G41UF series units are high efficiency upflow gas furnaces manufactured with Lennox DuralokPlus aluminized primary and stainless

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS Corp. 1101 L1 Service Literature Revised 03/2011 EL195UH EL195UH series units are high efficiency gas furnaces manufactured with Lennox DuralokPlus aluminized steel clamshell type heat exchangers, with

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0211 L3 Revised 09 2006 G60DFV(X) G60DFV(X) SERIES UNITS G60DFV series units are mid efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

Cooling Capacity CFM range

Cooling Capacity CFM range R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

GHR32Q/V SERIES UNITS

GHR32Q/V SERIES UNITS Service Literature GHR32Q/V Corp. 0001 L2 Revised 08 2004 This manual contains information pertaining to GHR32 1 through 6 model units. GHR32 series units are high efficiency horizontal or down flow gas

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler WTER HETING / OILERS CWMV PRODUCT SPECIFICTIONS Residential Hot Water Heat ir Handler ulletin No. 0434 ugust 05 Supersedes June 04 Heating Capacity - 3,700 to 0,000 tuh Nominal dd-on Cooling - to 5 Tons

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA G A S U N I T H E A T E R S / D U C T F U R N A C E S LF4 UNIT HEATERS Horizontal - 60 HZ Bulletin. 0000 June 0 Supersedes February 0 Front View Tubular Heat Exchanger Thermal

More information

G32V. Service Literature G32V SERIES UNITS

G32V. Service Literature G32V SERIES UNITS Service Literature G32V SERIES UNITS G32V series units are high efficiency upflow gas furnaces manufactured with DuralokPlus aluminized steel clamshell-type heat exchangers. G32V units are available in

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

TSTAT0201CW Recommended (sold separately)

TSTAT0201CW Recommended (sold separately) G9MVE QuietComfort ET 96 Product Specifications Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved Series A2 (or greater)

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

TSTAT0101SC Recommended (order separately)

TSTAT0101SC Recommended (order separately) Up to 98% AFUE Communicating, Modulating Gas Furnace EASIER TO SELL 98% AFUE on G9MAC0602120, all positions 97% AFUE, all other models, all positions All Models have earned the ENERGY STAR Modulating heating

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage, Variable Speed Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER variable speed ECM blower motor Supports two stage cooling units

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006) T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

Corp L12 Revised G24M SERIES UNITS

Corp L12 Revised G24M SERIES UNITS Service Literature G24M series units are mid efficiency gas furnaces manufactured with tubular steel heat exchangers formed of aluminized steel. G24M units are available in heating capacities of 45,000

More information

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE MULTIPOISE CONDENSING GAS Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed

More information

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh PA C KA G E D G A S / E L E C T R I C LRP14GE Residential - R-410A Bulletin No. 210720 November 2016 P R O D U C T S P E C I F I C AT I O N S Supersedes June 2016 SEER - 14.00 AFUE - 81% 2 to 5 Tons Cooling

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information