TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

Size: px
Start display at page:

Download "TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers"

Transcription

1 TECHNICAL MANUAL AL ARPT**4**, ARUF**4**, ASPT**4**, ASUF**4** Air Handlers Refer to Service Manual RS for installation, operation & troubleshooting information. All safety information must be followed as provided in the Service Manual. Refer to the appropriate Parts Catalog for part number information. Models listed on page. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. RT600r6 March 0 Copyright 0-0 Goodman Company, L.P.

2 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. A R U F 8 B 4 A A PRODUCT TYPE: A: Air Handler CABINET FINISH: P: Painted U: Unpainted EXPANSION DEVICE: F: Flowrater T: TXV (Expansion Device) CABINET WIDTH B: 7." C: " D: 4." REFRIGERANT CHARGE: 4: R-40A only MAJOR REVISION* MINOR REVISION* ELECTRICAL: : 08-0V/ph/60Hz APPLICATION: R: Multi-Position PSC Motor S: Energy Efficient Motor NOMINAL CAPACITY RANGE 8: -/ Tons 4: Tons 0: -/ Tons 6: Tons 4: -/ Tons 48: 4 Tons 49: 4 Tons 9: Tons 60: Tons All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 08-0v, 60 hz, phase. WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. WARNING Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WARNING Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death.

3 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. ARPT8B4** ARPT4B4** ARPT0B4** ARPT6C4** ARPT6D4** ARPT4D4** ARPT48D4** ARPT60D4** ASUF9B4** ASUF9C4** ASUF49C4** ASUF9D4** ASPT4B4** ASPT0C4** ASPT6C4** ASPT4D4** ASPT48D4** ASPT60D4** ARUF8B4** ARUF4B4** ARUF0B4** ARUF0C4** ARUF6C4** ARUF4C4** ARUF48D4** ARUF60D4** WARNING The United States Environmental Protection Agency ( EPA ) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING When installing or servicing this equipment, safety clothing, including hand and eye protection, is strongly advised. If installing this equipment in an area that has special safety requirements (hard hats etc.), observe these requirements. To protect the unit when brazing close to the painted surfaces, the use of a quenching cloth is strongly advised to prevent scorching or marring of the equipment finish. WARNING The unit MUST have an uninterrupted, unbroken electrical ground to minimize the possibility of personal injury if an electrical fault should occur. The electrical ground circuit may consist of an appropriately sized electrical wire connecting the ground lug in the unit control box to the building electrical service panel. Other methods of grounding are permitted if performed in accordance with the National Electric Code (NEC)/ American National Standards Institute (ANSI)/ National Fire Protection Association (NFPA) 70 and local/state codes. In Canada, electrical grounding is to be in accordance with the Canadian Electric Code CSA C.. Failure to observe this warning can result in electrical shock that can cause personal injury or death.

4 PRODUCT DESIGN WARNING If this appliance is installed in an enclosed area such as a garage or utility room with any carbon monoxide (CO) producing appliance (i.e. automobile, furnace, water-heaters, etc.), ensure the area is properly ventilated. HIGH VOLTAGE WARNING Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. AIR HANDLERS See Air Handler Specification Sheet for Proper Combinations. ALL AIR HANDLERS USE DIRECT DRIVE MO- TORS. POWER SUPPLY IS 08-0 V, 60 HZ, PHASE. Installation Before installing this appliance insure that it is properly sized and adequate power is available. This appliance can be installed in the vertical or right horizontal position without modification. The horizontal left and downflow positions require product modification. This product is designed for zero inches (0 inches) clearance; however, adequate access for service or replacement must be considered without removing permanent structure. This unit can be installed on a platform when deemed necessary. In an attic installation a secondary drain pan must be provided by the installer and placed under the entire unit with a separate drain line properly sloped and terminated in an area visible to the owner. This secondary drain pan is required in the event that there is a leak or main drain blockage. Closed cell insulation should be applied to the drain lines in unconditioned spaces where sweating may occur. Appliances installed in garages, warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing behind protective barriers, being elevated or located out of the normal path of vehicles. When installed on a base, the base must also be protected by similar means. Heating and cooling equipment located in garages, which may generate a glow, spark or flame capable of igniting flammable vapors, must be installed with the ignition source at least 8"[46cm] above the floor level. When more than one appliance is installed in a building it shall be permanently identified as to the area or space serviced by the equipment. When this product is installed in the downflow installation in an unconditioned space, remove the horizontal drain pan and install the following insulation kit. DFK-B Downflow Kit MODEL LIST FOR DOWNOW KITS DFK-C Downflow Kit DFK-D Downflow Kit ARUF8B4** ARUF0C4** ARUF48D4** ARUF4B4** ARUF6C4** ARUF60D4** ARUF0B4** ARUF4C4** ARPT6D4** ARPT8B4** ARPT6C4** ARPT4D4** ARPT4B4** ASUF9C4** ARPT48D4** ARPT0B4** ASUF49C4** ARPT60D4** ASUF9B4** ASPT0C4** ASUF9D4** ASPT4B4** ASPT6C4** ASPT4D4** ASPT48D4** ASPT60D4** This kit is used to prevent sweating on the vertical drain pan. ARPT, ARUF, ASPT and ASUF air handlers are multi-position, multi-speed with direct drive motors. ARPT and ARUF are available in / to ton sizes with optional kw to kw electric heat kits available for field installation. (See note below.) ASPT air handlers are available in,, 4 and ton sizes with optional kw to kw electric heat kits available for field installation. (See following note.) NOTE: Factory-sealed to achieve a % or less leakage rate at.0" water gauge external duct static pressure. Complies with the Factory-sealed Air Handling Credit as listed in the 00 Florida Building Code, Chapter, Section 60..A... 4

5 HKS HEAT KITS ARPT**4** Heat Kit Applications ARPT Type / model 8B4-A* 4B4-A* 0B4-A* 6C4-A* 6D4-A* 4D4-A* 48D4-A* 60D4-A* HKSX0XC* X X X X X X X X HKSX0XC* X X X X X X X X HKSX06XC* X X X X X X X X HKSX08XC* X X X X X X X X HKSX0XC* X X X X X X X X HKSC0XC* X X X X X X X X HKSC08XC* X X X X X X X X HKSC0XC* X X X X X X X X HKSCXA* X X X X X X HKSCXB* X X X X X X HKSCXF* X X X X X HKSC9CA* X HKSC9CB* X HKSC0DA* X X X X HKSC0DB* X X X X HKSC0XF* X X X X X HKSCDC* X X * Revision level that may or may not be designated Refer to the minimum airflow requirements for each of the heat kits.

6 HKS HEAT KITS ARUF**4** Heat Kit Applications ARUF Type / model 8B4-A* 4B4-B* 0B4-A* 0C4-B* 6C4-B* 4C4-A* 48D4-A* 60D4-A* HKSX0XC* X X X X X X X X HKSX0XC* X X X X X X X X HKSX06XC* X X X X X X X X HKSX08XC* X X X X X X X X HKSX0XC* X X X X X X X X HKSC0XC* X X X X X X X X HKSC08XC* X X X X X X X X HKSC0XC* X X X X X X X X HKSCXA* X X X X X X HKSCXB* X X X X X X HKSCXF* X X X X X HKSC9CA* X X X HKSC9CB* X X X HKSC0DA* X X HKSC0DB* X X HKSC0XF* X X X X X HKSCDC* X X X * Revision level that may or may not be designated Refer to the minimum airflow requirements for each of the heat kits. *ARUF ARPT HEATER (kw) B C Minimum CFM required for Heater Kits 6

7 HKS HEAT KITS ASPT**4** Heat Kit Applications ASPT Type / model 4B4-A* 0C4-A* 6C4-A* 4D4-A* 48D4-A* 60D4-A* HKSX0XC* X X X X X X HKSX0XC* X X X X X X HKSX06XC* X X X X X X HKSX08XC* X X X X X X HKSX0XC* X X X X X X HKSC0XC* X X X X X X HKSC08XC* X X X X X X HKSC0XC* X X X X X X HKSCXA* X X X X HKSCXB* X X X X HKSCXF* X X X X HKSC9CA* X HKSC9CB* X HKSC0DA* X X X HKSC0DB* X X X HKSC0XF* X X X X HKSCDC* X X X * Revision level that may or may not be designated. Refer to the minimum airflow requirements for each of the heat kits. HEATER (kw) ASPT Minimum CFM required for Heater Kits 7

8 HKS HEAT KITS ASUF**4** Heat Kit Applications ASUF Type / model 9B4-A* 9C4-A* 49C4-A* 9D4-A* HKSX0XC* X X X X HKSX0XC* X X X X HKSX06XC* X X X X HKSX08XC* X X X X HKSX0XC* X X X X HKSC0XC* X X X X HKSC08XC* X X X X HKSC0XC* X X X X HKSCXA* X X X HKSCXB* X X X HKSCXF* X X X HKSC9CA* X X HKSC9CB* X X HKSC0DA* X HKSC0DB* X HKSC0XF* X X X HKSCDC* X * Revision level that may or may not be designated. Refer to the minimum airflow requirements for each of the heat kits. HEATER (kw) ASUF Minimum CFM required for Heater Kits 8

9 PRODUCT DIMENSIONS ARPT**4**/ARUF**4**/ASPT**4**/ASUF**4** 9

10 PRODUCT DIMENSIONS ARPT**4**/ARUF**4** Model A B C D E F G H ARPT8B4* 4 6 /8 7 / 8 4 /6 8 /6 /6 ARPT4B4* 4 6 /8 7 / 8 4 /6 8 /6 /6 ARPT0B4* 4 6 /8 7 / 8 4 /6 8 /6 /6 ARPT6C4* 49 9 / /6 0 / /8 ARPT6D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 ARPT4D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 ARPT48D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 ARPT60D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 Dimensions are in inches. Model A B C D E F G H ARUF8B4* 4 6 / 8 7 / 8 4 / 6 8 / 6 / 6 ARUF4B4* 4 6 / 8 7 / 8 4 / 6 8 / 6 / 6 ARUF0B4* 4 6 / 8 7 / 8 4 / 6 8 / 6 / 6 ARUF0C4* 49 9 / / 6 0 / / 8 ARUF6C4* 49 9 / / 6 0 / / 8 ARUF4C4* 49 9 / / 6 0 / / 8 ARUF48D4* 8 / 6 4 / 8 / 6 / 6 / 6 / 6 / 8 ARUF60D4* 8 / 6 4 / 8 / 6 / 6 / 6 / 6 / 8 Dimensions are in inches. 0

11 PRODUCT DIMENSIONS ASPT**4**/ASUF**4** Model A B C D E F G H ASPT4B4* 4 6 /8 7 / 8 4 /6 8 /6 /6 ASPT0C4* 49 9 / /6 0 / /8 ASPT6C4* 49 9 / /6 0 / /8 ASPT4D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 ASPT48D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 ASPT60D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 Dimensions are in inches. Model A B C D E F G H ASUF9B4* 4 6 /8 7 / 8 4 /6 8 /6 /6 ASUF9C4* 49 9 / /6 0 / /8 ASUF49C4* 49 9 / /6 0 / /8 ASUF9D4* 8 /6 4 / 8 /6 /6 /6 /6 /8 Dimensions are in inches.

12 PRODUCT SPECIFICATIONS ARPT**4** ARPT 8B4* ARPT 4B4* ARPT 0B4* ARPT 6C4* ARPT 6D4* ARPT 4D4* ARPT 48D4* ARPT 60D4* Nominal Ratings Cooling (Btu/h) 8,000 4,000 0,000 6,000 6,000 4,000 48,000 60,000 Airflow Rate CFM * High Med Low Blower Diameter 9½" 9½" 9½" 0⅝" 0⅝" 0⅝" / 6 " / 6 " Width 6" 6" 6" 8" 0⅝" 0⅝" 0⅝" 0⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" Electrical Data Voltage 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 Min Circuit Ampacity / / / 4 / 4 4 / 4 / / 6 / 6 Max. Overcurrent Device (amps) / / / / / / / / Min. / Max VAC 97 / 97 / 97 / 97 / 97 / 97 / 97 / 97 / Blower Motor A/ HP.9 / ⅓.9 / ⅓.9 / ⅓. / ⅓.0 / ½. / ½./ ½ 4.6 / ¾ Ship Weight (lbs) *Airflow static

13 PRODUCT SPECIFICATIONS ARUF**4** ARUF 8B4* ARUF 4B4* ARUF 0B4* ARUF 0C4* ARUF 6C4* ARUF 4C4* ARUF 48D4* ARUF 60D4* Nominal Ratings Cooling (Btu/h) 8,000 4,000 0,000 6,000 6,000 4,000 48,000 60,000 Airflow rate CFM* High Med Low Blower Diameter 9½" 9½" 9½" 0⅝" 0⅝" 0⅝" 0⅝" / 6 " Width 6" 6" 6" 8" 8" 8" 0⅝" 0⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ⅞" ⅞" ⅞" Electrical Data Voltage 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 Min Circuit Ampacity / / / 4 / 4 4 / 4 4 / 4 / 6 / 6 Max. Overcurrent Device (amps) / / / / / / / / Min. / Max VAC 97 / 97 / 97 / 97 / 97 / 97 / 97 / 97 / Blower Motor A/ HP.9 / ⅓.9 / ⅓.9 / ⅓.0 / ⅓.0 / ⅓. / ⅓. / ½ 4.6 / ¾ Ship Weight (lbs) *Airflow static

14 PRODUCT SPECIFICATIONS ASPT**4** ASPT 4B4* ASPT 0C4* ASPT 6C4* ASPT 4D4* ASPT 48D4* ASPT 60D4* Nominal Ratings Cooling (Btu/h) 4,000 0,000 6,000 4,000 48,000 60,000 Airflow Rate CFM * T T T T4 T Blower Diameter 9½" 0⅝" 0⅝" / 6 " / 6 " / 6 " Width 6" 8" 8" 0⅝" 0⅝" 0⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" ¾" ¾" Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ⅞" ⅞" ⅞" ⅞" ⅞" Electrical Data Voltage 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 08 / 0 Min Circuit Ampacity / 4 / 4 4 / 4 / 6 / 6 6 / 6 Max. Overcurrent Device (amps) / / / / / / Min. / Max VAC 97 / 97 / 97 / 97 / 97 / 97 / Blower Motor A/ HP.7 / ¾. / ¾. / ¾ 4.8 / ¾ 6.7/ 6.7/ Ship Weight (lbs) *Airflow static

15 PRODUCT SPECIFICATIONS ASUF**4** ASUF 9B4* ASUF 9C4* ASUF 49C4* ASUF 9D4* Nominal Ratings Cooling (Btu/h) 4,000 6,000 49,000 60,000 Airflow Rate CFM * T T T T4 T Blower Diameter 9½" 0⅝" 0⅝" / 6 " Width 6" 8" 0⅝" 0⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" Suction ¾" ⅞" ⅞" ⅞" Electrical Data Voltage 08 / 0 08 / 0 08 / 0 08 / 0 Min Circuit Ampacity / 4 / 4 4 / 4 6 / 6 Max. Overcurrent Device (amps) / / / / Min. / Max VAC 97 / 97 / 97 / 97 / Blower Motor A/ HP.7 / ¾. / ¾.4 / ¾ 6.7 / Ship Weight (lbs) *Airflow static

16 OWER PERFORMANCE DATA ARPT**4** Model Number ARPT8B4 ARPT4B4 ARPT0B4 ARPT6C4 ARPT6D4 ARPT4D4 ARPT48D4 ARPT60D4 Blower Static Pressure (in w.c) Speed High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low AIROW DATA (CFM) ARPT**4** Notes: Airflow data indicated is at 0V without air filter in place. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. 6 Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations.

17 OWER PERFORMANCE DATA Model Number ARUF8B4* ARUF4B4* ARUF0B4* ARUF0C4* ARUF6C4* ARUF4C4AA ARUF4C4AB ARUF48D4* ARUF60D4* ARUF**4** Blower Static Pressure (in w.c) Speed High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low AIROW DATA (CFM) ARUF**4** Notes: Airflow data indicated is at 0V without air filter in place. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 7

18 OWER PERFORMANCE DATA Model Number ASPT4B4 ASPT0C4 ASPT6C4 ASPT4D4 ASPT48D4 ASPT60D4 Blower Speed Tap ASPT**4** Static Pressure (in w.c) AIROW DATA (CFM) ASPT**4** Notes: Airflow data indicated is at 0V without air filter in place. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 8

19 OWER PERFORMANCE DATA ASUF**4** Model Number Blower Speed Tap Static Pressure (in w.c) ASUF9B4 ASUF9C4 ASUF49C4 ASUF9D AIROW DATA (CFM) ASUF**4** Notes: Airflow data indicated is at 0V without air filter in place. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 9

20 WIRING DIAGRAMS ARPT**4**/ARUF**4** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR M R M HTR HTR M M R M M HTR HTR HTR M M M M M4 M R R HTR HTR HTR HTR4 M M M M7 4 M M4 M6 M8 R R L L L L L L L L ONE () ELEMENT ROWS TWO () ELEMENT ROWS THREE () ELEMENT ROWS FOUR (4) ELEMENT ROWS L L L L NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP IS NOT BELOW MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIR HANDLER/HEATER KIT COMBINATION ON THIS UNITS SERIAL PLATE. AFTER INST ALLING OPTIONAL HEAT KIT, MARK A "X" IN THE PROVIDED ABOVE. MARK ACCOING TO THE NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. ELEMENT ROWS DATA SUPPLIED WITH HEATER KIT. SEE NOTE TERMINAL OCK SHOWN FOR 0HZ MODELS ONLY L L EQUIPMENT GROUND USE COPPER WIRE 08/40 VOLTS GR SR PLF G L PLF L PLF PLM PLM PLM SEE NOTE 4 RC EM HI LO M M NC NO EBTDR COM SEE NOTE TR GR SPEEDUP COPPER POWER SUPPLY (SEE RATING PLATE) USE MIN. 7 C FIELD WIRE G EBTDR R K XFMR-R XFMR-C K C M IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. SEE NOTE NO COM NC M SEE NOTE THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE (TR ) (COM) (M) (M) RC LOW MEDIUM HIGH C EM SPEED 4V 4 SEE NOTE 40 TR RC EM EBTDR R 4 4V 6 4 PLF COLOR CODE ACK RED YELLOW GR GREEN RPLE OWN UE ITE COMPONENT CODE EM EVAPORATOR MOTOR RC RUN CAPACITOR SR STRAIN RELIEF R RELAY EBTDR ELECTRONIC OWER TIME DELAY RELAY NOTES: FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE TR PLF PLM HTR C EBTDR WIRING CODE ) RED WIRES TO BE ON TRANSFORMER TERMINAL "" FOR 40 VOLTS AND ON TERMINAL "" FOR 08 VOLTS. ) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. ) CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, UE FOR MEDIUM,AND ACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR. INACTIVE MOTOR WIRES SHOULD BE CONNECTED TO "M OR M" ON EBTDR. 4) OWN AND ITE WIRES ARE USED WITH HEAT KITS ONLY. ) EBTDR HAS A 7 SECOND ON DELAY EN "G" IS ENERGIZED AND A 6 SECOND OFF DELAY EN "G" IS DE-ENERGIZED. GR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS G 040A0008-B 0 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

21 WIRING DIAGRAMS ASPT**4**/ASUF**4** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR M R M HTR HTR M R M M M HTR HTR HTR M M M M M4 M R R HTR HTR HTR HTR4 M M M M7 4 M M4 M6 M8 R R L L L L L L L L ONE () ELEMENT ROWS TWO () ELEMENT ROWS THREE () ELEMENT ROWS FOUR (4) ELEMENT ROWS NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE. MARK ACCOING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. L L L L SEE NOTE R C G W W Y Y O DH 4 PLF PLM L G L EQUIPMENT GROUND USE COPPER WIRE L PLF PLM 08/40 VOLTS EM LGN L PLF PLM 4 CR WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE GR GR CR 4 A B COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 7 C FIELD WIRE IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. ALTERNATE HEAT RELAY 7 GR C 4 4V 4 40 TR SEE NOTE FUSE HOLDER OR SEE NOTE 4 EM 4 C L G N FUSE HOLDER NOTES: TR 4 4V 6 4 PLM SEE NOTE R C G W W Y Y O DH 4 B ) RED WIRES TO BE ON TRANSFORMER TERMINAL "" FOR 40 VOLTS AND ON TERMINAL "" FOR 80 VOLTS. ) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. ) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT RPLE WIRE FROM TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB. 4) OWN AND ITE WIRES ARE USED FOR HEAT KITS ONLY. A 4 7 CR ALTERNATE HEAT RELAY 4 EM C TR PLF PLM HTR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS COLOR CODE ACK RED YELLOW UE GR GREEN RPLE OWN ITE COMPONENT CODE EM EVAPORATOR MOTOR TB TERMINAL BOA R RELAY CR CONTROL RELAY EBTDR ELECTRONIC OWER TIME DELAY RELAY 040A0006-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

22 WIRING DIAGRAMS -Phase Heat Kit HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. kw Heat Kit HTR COMPONENT CODE COLOR CODE HTR HTR HTR4 HTR M M4 M6 M7 M M M M8 M0 M9 PC 4 R PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL OCK CB = CIRCUIT EAKER CC = CONTACTOR = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. OWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE = ACK = UE = OWN GR = GREEN OR = ORANGE PK = PINK = RPLE = RED = ITE = YELLOW R R NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE () ELEMENT ROWS CB CB CB NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION L L L L L L CB4 L L 040M0074-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting

More information

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat

More information

MBR. Multi-Position. Modular Blower

MBR. Multi-Position. Modular Blower M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic

More information

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features M Multi-Position, Multi-Speed Modular Blower With PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat Kit Data...

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features MBVC Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data...

More information

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in

More information

AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS NOTE: AR models are suitable for Upflow and Horizontal Installations only. Do not use for Downflow Installations RECOGNIZE THIS SYMBOL

More information

VERTICAL MOUNT AIR HANDLERS

VERTICAL MOUNT AIR HANDLERS VERTICAL MOUNT AIR HANDLERS INSTALLATION INSTRUCTIONS 2005-2009 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com P/N: IO-281J

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

INSTALLATION GUIDE. AAN & AEN Series - Manufactured Housing Electric Furnace. 1. Safety Instruction. 2. Inspection ! CAUTION CAUTION `!

INSTALLATION GUIDE. AAN & AEN Series - Manufactured Housing Electric Furnace. 1. Safety Instruction. 2. Inspection ! CAUTION CAUTION `! INSTALLATION GUIDE AAN & AEN Series - Manufactured Housing Electric Furnace. Safety Instruction Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction with

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

AE/AH R410A Window Air Conditioners & Heat Pumps

AE/AH R410A Window Air Conditioners & Heat Pumps TECHNICAL MANUAL AL AE/AH R410A Window Air Conditioners & Heat Pumps All safety information must be followed. See Installation instructions for more safety precautions. Refer to the appropriate Parts Catalog

More information

Installation Instructions

Installation Instructions Installation Instructions B5BV Series Electric Furnaces For HUD approved installations in manufactured homes and modular homes These instructions are intended to assist qualified individuals experienced

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES C US INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES Made in the USA by: Goodman Manufacturing Company, L.P. I0-240B 2550 North Loop West, Suite 400, Houston, TX 77092 www.goodmanmfg.com

More information

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006for troubleshooting information. All safety information must

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models MB08B1500A2 MB12F1900A2 MB16J2200A2 MB20N2600A2 Contents 115 Volt General Information / Installation... 2 Installations... 3 Horizontal Installations... 3 Ductwork Connections...

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access

More information

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. AMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

Installation Instructions

Installation Instructions H6HK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers IMPORTANT: The instructions included with this heater kit are for installations

More information

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton AEPT SERIES Multi-Position, Variable-Speed High-Efficiency Air Handler 2 and 5 Ton The AEPT air handler is compact for versatile upflow/downflow or horizontal multi-position installations and may be located

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

FEM4X. Product Specifications FAN COILS /14/15

FEM4X. Product Specifications FAN COILS /14/15 ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator

More information

TECHNICAL MANUAL. PBC/PBE/PBH Through-The-Wall R-410A Air Conditioners & Heat Pumps

TECHNICAL MANUAL. PBC/PBE/PBH Through-The-Wall R-410A Air Conditioners & Heat Pumps TECHNICAL MANUAL AL PBC/PBE/PBH Through-The-Wall R-410A Air Conditioners & Heat Pumps All safety information must be followed See Installation instructions for more safety precautions. Refer to the appropriate

More information

Bosch BVA Series Air Handler

Bosch BVA Series Air Handler Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications

More information

GKS9 40" 90% Gas Furnaces

GKS9 40 90% Gas Furnaces TECHNICAL MANUAL AL 40" 90% Gas Furnaces Refer to Service Manual RS6610004* for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device

More information

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton AEPT SERIES Multi-Position Air Handler 2 to 5 Ton The AEPT multi-position air handler is approved for modular homes and may be installed in a utility room, closet, aclove, basement or attic. Standard Features

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

Bosch BVA Series Air Handler

Bosch BVA Series Air Handler Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed

More information

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the

More information

WAHL A Product Specifications

WAHL A Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat

More information

REM4P, REM4X. Product Specifications

REM4P, REM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with

More information

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG: Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG: Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL MANUAL. GMH8 39 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal TECHNICAL MANUAL AL GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal Refer to Service Manual RS660004 for installation, operation, and troubleshooting information.

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The

More information

Models: Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20. Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20

Models: Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20. Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20 Models: COMFORT & ADVANTAGE (PSC MOTOR) Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20 Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20 INSTALLER / SERVICE TECHNICIAN:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG: Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Dimensions H x W x D in. (mm)

Dimensions H x W x D in. (mm) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

FXM4X. Product Specifications FAN COILS FXM4X

FXM4X. Product Specifications FAN COILS FXM4X ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 5 Ton Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

CBX32MV (HFC-410A) SERIES UNITS

CBX32MV (HFC-410A) SERIES UNITS Service Literature Corp. 005-L2 Revised November 5, 202 (HFC-40A) SERIES UNITS (icomfort-enabled) NOTICE A thermostat is not included and must be ordered separately. The Lennox icomfort thermostat must

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...

More information

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES ISO 9001 Certified Quality Management System GENERAL.............................................. 1 SAFETY................................................

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1000T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed

More information