NEMA Manual. Starters. NEMA Manual Starters Contents

Size: px
Start display at page:

Download "NEMA Manual. Starters. NEMA Manual Starters Contents"

Transcription

1 - February 007 NEMA Manual Starters Contents Page Types B0, B0, Switches MS Series, Single-Phase Starters Type B00, Single- and Three-Phase Starters Type 944, Reversing Drum Switches CA08000E

2 - Types B0, B0, Switches February 007 Contents Product Features Manual Switches Page Product Application Features Instructional Leaflet Standards and Certifications Wiring Diagrams Dimensions Product Selection Manual Switches are available in two- or three-pole configurations rated at 0A. Optional NEMA aluminum enclosure is supplied with a padlock guard for locking in the OFF or STOP position. Application Manual Switches provide manual control of single- and three-phase motors where overload protection is not required or provided separately. Applications include: Fans Blowers Pumps Wood Working Equipment Machine Tools Compact size Easy installation Simple operation Padlockable NEMA enclosure available Instructional Leaflet Pub7 Standards and Certifications UL File No. E4664, Category NLRV CSA File No. LR7088, Class -0 Wiring Diagrams -Pole B0BN -Pole B0AN B0AN L L T T -Ph. B0BN L L T T T T -Ph. B0AN L L L T T T T T T -Ph. Dimensions Figure -. Wiring Diagrams.0 (.0). (8.). (8.4). (7.).06 (.).44 (6.6) (0.) (8.). (60.).7 (7.7) (96.0) (60.) 4 #6- Tap.7 (69.9) #6- Tapped Holes for Wall Plate B0AN Ship. Wt. 4 oz. (. kg).0 (.) Dia. Mtg. Holes s B0BN and B0AN Ship. Wt. 6 oz. (.7 kg).0 (8.).0 (.) Holes. (.) Dia (7.) 4.7 (9.9).7.44 (69.9) (6.0).9 (.).4 (6.) Front View. (.7) Knockouts Holes.7 (6.9) Dia. Back View s B0AG, B0BG, B0AG Ship. Wt. 4 oz. (.40 kg) Figure -. Approximate Dimensions in Inches (mm) and Shipping Weights. (.7) x.7 (9.) Knockout Each End End View CA08000E

3 February 007 Types B0, B0, Switches - Product Selection When Ordering Specify of Manual Switch -Pole B0AN -Pole B0AN -Pole NEMA Enclosure B0BG Table -. Manual Switches without Overload Maximum Horsepower Ratings Open 0V 40V 480V 600V -Pole Manual Switches 0 -Pole Manual Switches B0AN B0BND NEMA Enclosed B0AG B0BGD 7-/ 0 B0AND B0AGD Discount Symbol CD-C CA08000E

4 -4 MS Series, Single-Phase Starters February 007 Contents Manual Starters Page Product Application Features Instructional Leaflet Standards and Certifications Accessories Dimensions Product Selection Modular Toggle Operated Starter Product The MS Starter is a compact, versatile unit featuring heavy sliding contacts as well as quick-make and quick-break mechanism Dimensions Standard with large pressure type terminals, straight-through wiring and a trip-free handle mechanism The plug-in heater element is keyed to ensure proper positioning and an adjustable knob allows a setting of plus or minus ten percent of the nominal heater rating Application The MS Manual Starter provides manual control and overload protection to single-phase motors. By utilizing the interchangeable heater elements, the starter can protect motors ranging from.40 amps up to 6.0 amps. Ideal for HVAC applications. Features Compact size Trip-free handle mechanism Keyed heater elements to ensure proper installation Starters available with red pilot light The operating handle of the enclosed units can be locked in the OFF position Enclosures are offered in NEMA,, 4 and Hazardous locations cast aluminum enclosures are available rated for Type 7, Class I, Group D (vapors) and Type 9, Class II, Groups E, F an G (dust). Instructional Leaflet IL987G Standards and Certifications UL File No. E9, Category NLRV CSA File No. LR940-6, Class -0 Accessories Table -. MS Accessories Pilot Light Kit (NEMA Enclosure and Flush Plates) Box, Unit (NEMA Enclosure) Cover, Unit (NEMA Enclosure) Flush Plate, Unit (Steel) Flush Plate, Unit (Stainless Steel) Handle Guard (Padlockable for NEMA Enclosure and Flush Plates) MSPT MSBN MSCN MSFN MSDN MSLG.6 (9.) Dia..6 (4.).7 (69.).06 (.). (.8) Height of Handle.9 (4.8)..8 (7.9) (8.) 0 Typ..7 (9.).8 (96.8).8 (40.).9 (48.).7 (8.).70 (4.). (.8). (7.9). (.6).9 (0.).64 (4.7). (60.).4- Tap MS Starter Toggle Operated Open Units Figure -. Approximate Dimensions in Inches (mm). (.) 4. (4.).7 (69.9) Mounting Purposes () Holes.06 (6.9).8.66 (8.) (6.8).64 (4.7) Handle Guard. (.6). (7.). Indicating Light (7.9) Unit Flush Plates Unit. (60.).4.6 (0.4) (9.6) 4.6 (0.7). (4.0) Indicating Light Handle.06 Guard (77.7).0 (.) Diameter () Mounting Hole Type Enclosures (Boxes and Covers). (.6).64 (4.7).78 (9.8).4 (8.6). (.9).8 (8.).8 (7.9). (64.8).47 (6.7). (.6).97 (0).7 (9.) Pipe Tap.6 (9.).7 (9.).9 (7.9).7 (9.) Pipe Tap Watertight (Cast Aluminum).94 (00.).8 (0.6).0 (7.6) Dia. Lockout Hole. (88.9).6 (66.8).4 (8.6) Dia. () Mounting Holes Hazardous Location (Cast Aluminum).8 (47.6). (0.) 6.7 (70.7).88 (49.4).44 (.) Discount Symbol CD-C CA08000E

5 February 007 MS Series, Single-Phase Starters - Product Selection When Ordering Specify of Manual Starter Heater Pack selection Any required Accessories Heater Coil selection according to the motor full load current requirements Table -. Product Selection MS Series Starters of Poles Open Type /4 /4 /4 Flush Plate (No Enclosure Included) Horsepower Voltage 0/40V, 77V AC 0/40V DC V DC 0/40V, 77V AC 0/40V DC V DC Flush Plate Type General Switch Only Switch with Pilot Light Purpose Switch Only Switch with Pilot Light Stainless Steel Switch Only Switch with Pilot Light Switch Only Switch with Pilot Light Enclosed Types Enclosure Type General Switch Only Switch with Pilot Light Purpose Switch Only Type Switch with Pilot Light MST0 MST0 MST0FN MST0FNP MST0FN MST0FNP MST0DN MST0DNP MST0DN MST0DNP MST0SN MST0SNP MST0SN MST0SNP Waterproof Through Hub MST0AH Type, 4 & Through Hub MST0AH Hazardous Location Through Hub MST0EH Types 7D, 9E, 9F & 9G Through Hub MST0EH Does not include heater. Select heater from Table -4. Type 7D = Type 7, Class I, Group D; Type 9E, 9F and 9G = Type 9, Class II, Groups E, F and G. Switch and Pilot Light Mounted on Flush Plate Switch and Pilot Light Mounted in Type Enclosure Waterproof Type, 4 & Typical Heater Table -4. Heater Selection for MS Starters Full Load Current Full Load Current Heater Element Installation Full Load Current Hazardous Location Type 7D, 9E, 9F & 9G Full Load Current MSH-A MSH-A MSH-6A MSH-67A MSH-74A MSH-8A MSH-89A MSH-98A MSH-A MSH-A MSH-A MSH-4A MSH-6A MSH-7A MSH-9A MSH-A MSH-A MSH-A MSH-8A MSH-A MSH-4A MSH-7A MSH4-A MSH4-A MSH-0A MSH-A MSH6-0A MSH6-6A MSH7-A MSH8-0A MSH8-8A MSH9-7A MSH0-6A MSH-7A MSH-9A MSH4-A MSH-6A MSH7-A MSH8-6A Discount Symbol CD-C CA08000E

6 -6 Type B00, Single- and Three-Phase Starters February 007 Contents Manual Starters Page Product Application Features Instructional Leaflet Standards and Certifications Technical Data Options Accessories Dimensions Product Selection Features Includes three-pole bimetallic overload relay Straight-through wiring Field mounted auxiliary contacts Available in NEMA, 4, 7, 9 and enclosures with toggle operation (NEMA enclosure for pushbutton operator) Standard with a lockout device to lock motor in the OFF position Technical Data Instructional Leaflet IL4890 Standards and Certifications UL File No. E9, Category NLRV CSA File No. LR940-6, Class -0 (Open Starters) CSA File No. LR47-, Class -0 (Closed Starters) Table -. Specifications NEMA Maximum hp for AC Ratings Maximum hp for DC Ratings Size 0V AC 08 40V AC V AC V DC 0V DC -Pole, Single-Phase M-0 M- -Pole, Three-Phase M-0 M- 7-/ 0 Ratings up to hp, -phase are suitable for group fusing. -/ -/ Options Accessories Pushbutton Operated Product The B00 Manual Starters can be used in single-phase applications rated hp at 40V AC or hp at 0V DC. The starter can also be rated for three-phase applications up to 0 hp at 600V AC. There are two methods of operation for the B00 Manual Starter. It can be ordered with a toggle switch operator or a START/STOP pushbutton operator. Table -6. Factory Modifications Suffix Adder Pushbutton operator A (open and NEMA only) Without lockoff X (open only) Add Suffix letter to starter Ex: B00MOCA. Table -7. Accessories Field Mounting Kits NO elect. auxiliary BA NC elect. auxiliary BB Red pilot light 0/60 LK- (NEMA Enc. Only) Red pilot light 08-40/6 LK- (NEMA Enc. Only) Red pilot light /60 LK-6 (NEMA Enc. Only) For Type 4 and Enclosures Only Red pilot light 0V Red pilot light 40V LK-4 LK-4 Application The B00 family of Manual Starters provides manual control, as well as overload protection, to both single-phase and three-phase motors. The starter protects motors up to.9 amp single-phase and 6.8 amp three-phase with the appropriate heater selection. Discount Symbol CD-C CA08000E

7 February 007 Type B00, Single- and Three-Phase Starters -7 Dimensions 4.7 (9.9).6 (9.9).0 (6.7) 4.98 (6.).98 (0.).0 (.9).6 (6.0). (0.) (7) 7.9 (9.8) OFF.9 (.4) 9.9 (.4). (.6) Dia. 4 Mtg. Holes 6.0 (.4).6 (6.0). (8.6).9.6. (.4) (4.4) (.).0 / x /4 Conduit K.O. (76.) in Each Side.09 (.) 0.6 (8.) 8.8 (0.). (.8).0. (.9) (6.) Type Enclosed / x /4 Conduit K.O. in Bottom and in Top End /6- Mounting Screw.8 (4.).84 (48.).7 (4.) 6.0 (.4).0 (.).6 (6.0) Type 4 Enclosed 6.0 (.). (0.) 7. (8.).6 (90.4).9 (8.0) 4.9 (6.6) Open, Non-reversing Starter.6 (6.0). (0.) (7).7 (6.9).06 (06.) 0. (60.4) OFF ON 8. (.9) 4.9 (06.4) 9.9 (.4) 8.8 (0.) 9.4 (9.0) 4.06 (0.).4 (0.4) Slot Req'd. 8. (09.6). (.).0 (.4)-.0 NPSK Holes. (.) 6. (60.) 7.77 (97.4).97 (.6). (.7).88 (.4) 6.0 (.4) Type 7 & 9 Enclosed. (9.) 4.78 (.4) Type Enclosed Figure -4. Approximate Dimensions in Inches (mm) CA08000E

8 -8 Type B00, Single- and Three-Phase Starters February 007 Product Selection When Ordering Specify of Starter with application modifications Heater Pack selection A threephase starter requires three heaters, and a single-phase starter requires two heaters Any required Accessories Toggle Operated Type Enclosure Table -8. Product Selection Toggle and Pushbutton Operated Starters NEMA Size Open Type Toggle Handle Enclosed NEMA General Purpose Type B00 Non-reversing -Pole (For Single-Phase s and DC) M-0 M- B00M0B B00MB B00S0B B00SB Type B00 Non-reversing -Pole (For Polyphase s) M-0 M- B00M0C B00MC B00S0C B00SC NEMA 4 Watertight, Stainless Steel B00W0B B00WB B00W0C B00WC One -inch chrome hub supplied on each end. NEMA 7D = NEMA 7, Class I, Group D. NEMA 9E, 9F and 9G = NEMA 9, Class II, Groups E, F and G. Starter does not include heaters. Select s of heaters from Table -9. Tapped for -inch conduit on each end. NEMA 7D, 9E, 9F & 9G for Hazardous Locations B00U0B B00UB B00U0C B00UC NEMA Dust-Tight B00J0B B00JB B00J0C B00JC Discount Symbol CD-C CA08000E

9 February 007 Type B00, Single- and Three-Phase Starters -9 Table -9. Heater Selection Full Load Current Max. Fuse Amps Single-Phase Enclosed Starters FH0 FH04 FH0 FH06 FH07 FH08 FH09 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH FH9 FH40 FH4 FH4 FH4 FH44 FH4 FH46 FH47 FH48 FH49 FH0 FH FH FH FH4 FH FH6 FH7 Full Load Current Single-Phase Starters require two overload heaters. Three-Phase Starters require three overload heaters. Max. Fuse Amps Three-Phase Enclosed Starters FH0 FH04 FH0 FH06 FH07 FH08 FH09 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH8 FH9 FH0 FH FH FH FH4 FH FH6 FH7 FH FH9 FH40 FH4 FH4 FH4 FH44 FH4 FH46 FH47 FH48 FH49 FH0 FH FH FH FH4 Note: FH Series heaters are for Type B00 manual motor starters. Heater element selection is based on motor nameplate s listed full load amperes. Trip rating of this series of elements is % of minimum motor full load amperes listed for the element. When motor and overload relay are in the same ambient and the service factor of the motor is. to., select heaters from the heater selection table. If the service factor is.0 or less (including zero), or a maximum of % protection is desired, select a heater one size smaller than indicated for the amperage range required. Discount Symbol CD-C CA08000E

10 -0 Type 944, Reversing Drum Switches February 007 Contents Application Operation Reversing Drum Switches Page Application Features Operation Standards and Certifications Wiring Diagrams Dimensions Product Selection Type DB and DD These drum switches are designed primarily for use with single-phase and squirrel cage, single-speed reversible motors which may be connected directly across-the-line. Typical applications would be hoists and machine tools. Features Compact size Front mounting easily installed Terminals front accessible slanted 4 for extra convenience Captive pressure clamps on terminal screws back off with screw no prying with screwdriver necessary Choice of operators Large Knob Orientation of operator independent of legend 60 positioning in -/ increments pointer remains oriented to legend Field convertible from maintained to momentary operation Replaceable, large volume, silver plated contacts Oiltight machine cavity or surface mounting types Modern attractive appearance All of the operators may be rotated 60 in -/ increments without losing the indication of the drum position. A red-lined pointer is permanently orientated to the legend markings and clearly indicates the selected drum function regardless of the selected setting for the operator. This enables the user to offset the operator to afford the most comfortable operating position. This is accomplished simply by loosening and retightening one screw. Standards and Certifications UL File No. E76, Category NLRV CSA Guide No. 84-N-.A, Class Wiring Diagrams L S L A S Single-Phase s Single-Phase s Polyphase s F DC s L F F S T T4 L T L T L T L A Shunt Field 4 A 4 T8 T8 4 T8 4 T4 T 4 L A 4 S S S 6 A L 6 T L 6 T L 6 T L 6 T L 6 S Series Field A A A T T4 T T T4 TTT Arm Arm T T8 T T8 T8 T F S For Shunt Split- Split- M Add Jumper Universal Phase Capacitor -Wire 4-Wire Capacitor-Start -Phase -Wire Series, Compound, Shunt Repulsion-Start Induction, Repulsion, Repulsion-Induction Figure -. Wiring Diagrams CA08000E

11 February 007 Type 944, Reversing Drum Switches - Dimensions Table -0. Approximate Dimensions and Shipping Weights Size Surface Mounting DB & DB DD & DD Cavity Mounting DB & DB DD & DD Type of Operator Knob Knob Knob Knob Dimensions in Inches (mm) Wide A.0 (6.).0 (6.). (8.9). (8.9) 4.00 (0.6) 4.00 (0.6) 4.0 (4.) 4.0 (4.) High B.88 (49.4). (6.7) 6.88 (74.8) 6. (8.8) 4.7 (0.7) 4.0 (4.).7 (46.). (0.) Deep C 4. (.).00 (76.) 4.7 (0.7).6 (9.).00 (7.0) 4.0 (4.). (.4) 4.6 (7.6) Mounting D.00 (0.8).00 (0.8).6 (66.8).6 (66.8).0 (88.9).0 (88.9) 4.00 (0.6) 4.00 (0.6) E. (7.). (7.).7 (69.9).7 (69.9) 4.00 (0.6) 4.00 (0.6) 4.0 (4.) 4.0 (4.) F.88 (47.8). (.).00 (0.8). (.).88 (47.8). (.).00 (0.8). (.) Shipping Weights Lbs. (kg).0 (.4).0 (.4) 4.0 (.8) 4.0 (.8).0 (.4).0 (.4) 4.0 (.8) 4.0 (.8) E F B E B.0 (88.9) Size DB and DB.88 (98.6) Size DD and DD D A C D A F C.00 (76.) Size DB and DB. (8.6) Size DD and DD Figure -6. Approximate Dimensions Surface Mounting Product Selection When Ordering Supply Figure -7. Approximate Dimensions Cavity Mounting Figure -8. Approximate Dimensions Panel Cutout Cavity Mount Type DB Flush Mount Standard Type DB and DD Surface Mounting Standard Type DB Flush Mount Knob Operator Type DB and DD Surface Mounting Knob Operator Table -. Reversing Drum Type without Overload Relay Maximum Horsepower Size Type of Operation -Phase Single- Phase DC Surface Mounting General Purpose NEMA Operator Flush or Cavity Mounting (Oiltight Mounting on Sizes DB and DD) These devices are field convertible from maintained both positions to momentary both positions. These devices are field convertible from maintained FORWARD and momentary REVERSE to momentary FORWARD and maintained REVERSE. Knob Operator 00 0V 0 7V V 0V V 0V -Pole -/ DB Maintained 944H68 944H69 944H74 944H7 Maintained and 944H7 944H7 944H76 944H77 Momentary -/ DB Maintained 944H 944H4 944H47 944H48 Maintained and 944H6 944H7 944H49 944H0 Momentary 7-/ -/ DD Maintained 944H84 944H8 944H8 944H87 7-/ 0 DD Maintained 944H6 944H6 944H6 944H64 Knob Discount Symbol CD-C CA08000E

12 - February 007 CA08000E

BULLETIN 600 SINGLE PHASE

BULLETIN 600 SINGLE PHASE BULLETIN 600 SINGLE PHASE Bulletin 600 Starting and overload protection of small 1-phase AC/DC motors used on the following: Unit heaters Fans Stokers Pumps Refrigeration compressors Bulletin 600 manual

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018 SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase

Features: No reversing, Non-combination, Open, NEMA Type 1 NEMA Sizes 00-9 with Thermal Overload Relay 600 Volts Maximum 50/60 Hertz Three Phase Starters and Contactors Definite Purpose Contactors Standard, Open Type Ampere Rating Coil Voltage No of Pole Voltage CR353AB2AA1GE 25 110-120 @ 50/60 Hz 2 600 CR353AC3AH1GE 30 24 VAC @ 50/60 Hz 3 600

More information

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled I P Explosion Proof Starter 1Ø & 3Ø, 115~600VAC, 1 75HP START/STOP AND RESET PUSHBUTTONS ELECTRONIC MOTOR PROTECTION Tough Starters for Tough Environments Ready to Install, Completely Wired and Assembled

More information

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof Contender Series Factory Sealed Manual Motor Starters and Contactors Applications Manual motor starters are available to meet any plant installation requirement. They may be used to install a variety of

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes ac,

More information

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof Contender Series Factory Sealed Manual Motor Starters and Contactors Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Applications Manual motor starters are available to meet any plant

More information

Bulletin 609 Single And Three Phase

Bulletin 609 Single And Three Phase Bulletin 609 Single And Three Phase Bulletin 609 Single or three phase motor starting with overload protection up to 600V AC Contact position indicator Locking features Available in open style or as an

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM. CUSTOM CONFIGURED PRODUCTS READY FOR SHIPMENT IN ONE TO TEN BUSINESS DAYS. Appleton s Quick Response Program places select power and control products

More information

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s FANs 930, 125 Product/Technical Bulletin S350 Issue Date 0300 The S350A, S351A, and S352A Stage s are intended to be used with System

More information

Powers TM Controls ET 134 Line Voltage Room Thermostats

Powers TM Controls ET 134 Line Voltage Room Thermostats Powers TM Controls ET 134 Line Voltage Room Thermostats Technical Instructions Document No. 155-017P25 ET 134-55 134-1083 134-1084 &134-1085 Exposed Knobs 134-1084 & 134-1085 Concealed Adjustment 134-1086

More information

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931) DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee 37091 Phone (931) 359-6211 1-800-251-8990 www.doleref.com ECONO-MAN 1 ECONO-CEL OPERATION & MAINTENANCE MANUAL June 2002 Econo-Cel Table

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Powers Controls Low Temperature Detection Thermostat

Powers Controls Low Temperature Detection Thermostat Document No. 155-016P25 ET 134-22 Rev. 1, February, 2000 Powers Controls Low Temperature Detection Thermostat Description The electric Low Temperature Detection Cut-out and Alarm Thermostat is a remote

More information

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

ELECTRONIC FLAME SUPERVISION MULTI-BURNER MULTI-BURNER MODEL: SENS-A-FLAME II Revision: 0 7112 DESCRIPTION Model 7112 Sens-A-Flame II is a second generation solid-state programmable combustion safeguard for supervising multiple burner ovens, furnaces,

More information

MICRO SWITCH BAF/DTF Series

MICRO SWITCH BAF/DTF Series MICRO SWITCH BAF/DTF Series High Capacity Enclosed Switches DESCRIPTION MICRO SWITCH BAF1 high capacity enclosed switches offer elastomer boot on sealed actuator verions that protects the actuating mechanism

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Powers Controls ET 134 Low Temperature Detection Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...

More information

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof EDS Series Factory Sealed Manual Motor Starters and Contactors Class I, Division 1 and 2, Groups C, D Applications Manual motor starters are available to meet any plant installation requirement. They may

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Table of Contents. Protective Relays

Table of Contents. Protective Relays Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3

More information

Thermostat KPU. Data sheet

Thermostat KPU. Data sheet Data sheet Thermostat KPU The KPU Thermostats are temperature controlled electrical switches, which are applied for regulation and safety monitoring of refrigeration and air conditioning systems. KPU sensors

More information

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information: RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation

More information

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat. Document No. 155-018P25 ET 141-1 ET 141 Electric Surface Mounted Thermostat Description This electric surface mounted thermostat has a Single-Pole, Double-Throw (SPDT) contact mechanism and is designed

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS SECTION 26 09 23 LIGHTING CONTROL DEVICES AND CONTROL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Remote control lighting relays. 2. Lighting contactors. 3. Switches. 4. Switch plates.

More information

Vibratone Horns. Models 350 and 450

Vibratone Horns. Models 350 and 450 FEDERAL SIGNAL CORPORATION Vibratone Horns Models 350 and 450 DESIGNED FOR ROUTINE SIGNALING Range of up to 200 feet Coded or sustained tones Model 350 12, 24, 120 and 240VAC; Model 450 12, 24, 125 and

More information

Engineered Solutions SYSTEMS CUSTOM ENGINEERED TO YOUR SPECIFICATIONS. Fused Coordination Panelboards...ES 2. Fusible Shunt Trip Switch..

Engineered Solutions SYSTEMS CUSTOM ENGINEERED TO YOUR SPECIFICATIONS. Fused Coordination Panelboards...ES 2. Fusible Shunt Trip Switch.. ngineered olutions YTM CUTOM NGINRD TO YOUR PCIFICATION Your problem: You need to achieve code compliance and protect critical power operations with selective coordination. You need a UL Listed industrial

More information

PART GENERAL 1.01 SECTION INCLUDES

PART GENERAL 1.01 SECTION INCLUDES Specification Number: 26 24 16.06 Product Name: Emergency Lighting Control NQ Circuit Panelboards: 240 Vac, 48 Vdc Maximum SECTION 26 24 16.06 Emergency Lighting Control NQ Circuit Panelboards: 240 Vac,

More information

Electronic Control Pushbutton

Electronic Control Pushbutton Electronic Control Pushbutton INCANDESCENT OR NON-LIGHTED DISPLAY Buttons ordered separately. AML21 Series Electrical Data page 19 Buttons page 43 Lamps and LEDs page 58 Accessories pages 56, 57 Mounting

More information

EJB Custom-Built Control Panels

EJB Custom-Built Control Panels EJB Custom-Built Control Panels Cl. I, Div. 1 & 2, Groups B*, C, D Cl. I, Zones 1 & 2 Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III UL and cul approved Ex d IIB + H2 T6 Certified to

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00 I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

MaxGard. Interconnection Systems. Durability. Performance. Safety

MaxGard. Interconnection Systems. Durability. Performance. Safety 8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections:

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

Instruction Manual Model A

Instruction Manual Model A 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED

More information

FTA200-A REMOTE ALARM PANEL

FTA200-A REMOTE ALARM PANEL FTA200-A REMOTE ALARM PANEL (FOR USE WITH ELECTRIC FIRE PUMP CONTROLLERS) STANDARD SUBMITTAL PACKAGE SBP200A FTA200-A Remote Alarm Panels for Electric Fire Pump Controllers Product Description Type A -

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

a thriving company in a dynamic industry

a thriving company in a dynamic industry a thriving company in a dynamic industry At Sprecher + Schuh, helping our customers succeed is what we do best with industrial control and informative solutions designed to give our customers a competitive

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

Two-Position Electric Duplex Room Thermostats

Two-Position Electric Duplex Room Thermostats TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features:

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE Because of changes in installation codes, the increasing complexity of the equipment involved, and other factors, more and more markings are being used on electrical heating and cooling equipment.

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large

More information

Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications 480 VAC, 70A Main Power Distribution Panel NOVA Energy & Automation Product Specifications 480 VAC, 70A Main Power Distribution Panel Model NEAS-43070-ST 29 July 2012 Product Description 1. Standard Applications The Nova NEAS-43070-ST system Main

More information

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000 Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act

More information

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats. Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code

More information

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2. Shown with optional

More information

Copy Right By: Thomas T.S. Wan

Copy Right By: Thomas T.S. Wan Chapter 23 Motor and Starter Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Electric Motors All the motors are to be designed and constructed in accordance with NEMA code. Electric

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance 5 List of

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION SALES REFERENCE DATE (Supersedes PF99-1) AUGUST, 2010 Portable Industrial Unit Blower Air Types SDRA and SDRA-RG SECTION SDRA

More information

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes Part #: EPS-PB10-MS-AT-V3 Made in the USA The Larson Electronics EPS-PB10-MS-AT-V2 Explosion Proof Push

More information

Thermostats and Accessories

Thermostats and Accessories Thermostats and Accessories SERIES EHG...641 SERIES EHG SL10...643 ST10 and ST207...647 Bulb and Capillary...649 Low Liquid Level Sensors...653 Protective Wells...654 639 640 WATLOW SERIES EHG Many applications

More information

ENERVEX RSV CHIMNEY FAN

ENERVEX RSV CHIMNEY FAN ENERVEX RSV 200-450 CHIMNEY FAN 3000775 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:

More information

EATON DFDAP-M / FDAP-M Remote Alarm Panels

EATON DFDAP-M / FDAP-M Remote Alarm Panels O & M Manual IM05805008K O & M Manual IM05805008K TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER 1 2. ELECTRICAL CONNECTIONS 1 2.1 ELECTRICAL CHECKOUT INSTRUCTIONS 2 2.2 ELECTRIC ALARM

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations

More information

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System DualPak Series 6900 FILE NO: 62.11 DATE: Feb. 15, 1999 SUPERSEDES: 62.11 DATE: Sept. 28, 1995 DualPak 6900 Series Booster System D U A L P A K 6 9 0 0 Armstrong proudly presents the Series 6900 DualPak

More information

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

A11 Series Low Temperature Cutout Controls

A11 Series Low Temperature Cutout Controls Code No. LIT-1927005 A11 Series Low Temperature Cutout Controls A11 Series Low Temperature Cutout Controls are available with single-pole, single-throw SPST or single-pole, double-throw SPDT contact action.

More information

FDJ SERIES Jockey Pump Controllers Features

FDJ SERIES Jockey Pump Controllers Features 1-1 NEMA 2 Enclosures Enclosures have an oven baked powder paint finish and are supplied with NEMA 2 rating, unless otherwise ordered. Available options include: NEMA 1, 3R,, X, 12. Note: NEMA, X enclosures

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

Temperature, Mechanical

Temperature, Mechanical Temperature, Mechanical Catalog Number Explanation Note:Catalog numbers must not include blank spaces. 837 A 4 A X 5 08 X171 C a b c d e f g a Style of Device A H V Remote bulb and capillary Direct horizontal

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

BEHIND THE PANEL AML s simple, cost effective design provides many behind-panel benefits for the designer and installer/user.

BEHIND THE PANEL AML s simple, cost effective design provides many behind-panel benefits for the designer and installer/user. Advanced Manual Line IN FRONT OF THE PANEL Coordinated, attractive appearance. AML features innovations designed by industrial designers to achieve the best balance of human factors and aesthetic appearance.

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

CP CP

CP CP CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling

More information

Tubular Industrial Process

Tubular Industrial Process consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater Products Company Markel Products Company Markel Products Company Markel Products Co HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C &

More information

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete

More information

Product Specifications 480 VAC, 175A Main Power Distribution Panel

Product Specifications 480 VAC, 175A Main Power Distribution Panel NOVA Energy & Automation Product Specifications 480 VAC, 175A Main Power Distribution Panel Model NEAS-43175-ST 29 July 2012 Product Description 1. Standard Applications The Nova NEAS-43175-ST system Main

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series HEAT PUMPS 7.5 TO 10 TONS 506148 01 12/08 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act of 1990 bans the intentional

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

Sprecher + Schuh Motor Control and Protection Products

Sprecher + Schuh Motor Control and Protection Products Sprecher + Schuh Motor Control and Protection Products oil and gas pumping, irrigation and piping elevator and hydraulic lifts food processing We consistently work on improving our products and processes

More information

AIR TO AIR HEAT EXCHANGERS

AIR TO AIR HEAT EXCHANGERS AIR TO AIR HEAT EXCHANGERS HEAT PIPE TECHNOLOGY CLOSED LOOP DESIGN AVAILABLE IN 120, 230, 24VDC & 48VDC NEMA TYPE 12, 4 AND 4X UL LISTED FOR STANDARD AND HAZARDOUS LOCATIONS A2A SERIES AIR TO AIR HEAT

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

T P A 120 S 4 S N 1 Y

T P A 120 S 4 S N 1 Y PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating

More information

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257 email: seekirk@seekirk.com

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ Cooling/Heat Pump Convertible Air Handlers 2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ 5 Ton Preliminary PUB. NO. 22-1777-04 Features and

More information

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 INSTALLATION-OPERATION-MAINTENANCE CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 TEFC 3 phase motor Outlet duct Fan wheel housing Inlet duct connection After filter transition Optional after filter unit

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and

More information

FT60 Reduced Voltage - Autotransformer

FT60 Reduced Voltage - Autotransformer 1-1 Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer

More information

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information