General Catalogue 2011

Size: px
Start display at page:

Download "General Catalogue 2011"

Transcription

1 PRELIMINARY 2 All Seasons CLIMATE COMFORT Heating Air Conditioning General Catalogue 2011 Applied Systems Refrigeration

2

3 TABLE OF CONTENTS Table of contents 1 New products Daikin's 4 pillars of growth 6 Heating & Cooling 8 Environmental awareness 10 Ecolabel 11 We Care icons 11 Energy labelling 12 Seasonal Efficiency 13 Daikin solutions to R22 phase out 14 Air purifier 16 Heating Air to water heat pumps 22 Daikin Altherma low temperature 24 Daikin Altherma high temperature 44 Daikin Altherma for apartment buildings and collective housing 50 Daikin heat pump convector 54 Domestic hot water heat pump 55 Air to air heat pumps 56 Residential applications VRV 60 Air conditioning Residential applications 67 Pair applications 72 Multi model applications 85 Light commercial applications 115 Pair applications 118 Commercial multi system 152 Twin, triple, double twin applications 154 Rooftop 164 VRV 167 VRV outdoor units 170 VRV indoor units 192 Hot water 210 Powerful selection programmes 211 Applied systems Chillers Air cooled chiller 230 Water cooled chiller 239 Water cooled condenserless chiller 242 Centrifugal chiller 279 Fan coil units 247 Refrigeration Convenipack 258 ZEAS condensing units 262 Commercial condensing units 264 Large variable capacity condensing unit 265 Control systems, options & accessories Control systems 268 Options & accessories 274 Ventilation & Biddle Air Curtain 213 Marine Types 223

4 NEW PRODUCTS 2011 DAIKIN ALTHERMA LOW TEMPERATURE SPLIT FLOOR STANDING INDOOR UNIT 26 Space saving: indoor unit and domestic hot water tank can be stacked on each other Reduced installation time State of the art design Savings on running cost DAIKIN ALTHERMA LOW TEMPERATURE SPLIT OUTDOOR UNIT FOR COLD CLIMATES ERLQC 32 High capacity at low outdoor temperature Increased operation range down to 25 C High efficient defrost thanks to the hot gass pipe and the redesigned side plate DAIKIN ALTHERMA LOW TEMPERATURE 6 AND 8KW MONOBLOC 35 Extended range: 6 and 8 kw All hydraulic parts included in the outdoor unit Only water connection between outdoor unit and indoor appliances DOMESTIC HOT WATER HEAT PUMP 55 Standalone domestic hot water production Low primary energy use, low CO 2 emissions High efficiency by inverter technology and intelligent control Reliable and maintenance free Superior performance and quality Plug and play system

5 57 NEXURA FLOOR STANDING UNIT WITH RADIANT HEAT PANEL Radiant heat panel for optimal heat distribution in a room Optimal comfort all year round Extremely silent operation: down to 19dBA Low air flow rate Full range A class energy label Stylish design that blends in any interior 118 SKY AIR OUTDOOR UNIT, OPTIMIZED FOR SEASONAL EFFICIENCY RZQGL Seasonal efficiency, optimized for all seasons Improved seasonal efficiency SEER in combination with FCGQE and FHQGC Pair application Costeffective upgrade from R22/R407C to R410A length up to 75m ROUND FLOW CASSETTE, OPTIMIZED FOR SEASONAL EFFICIENCY FCQGE Seasonal efficiency, optimized for all seasons New decoration panel finished in fresh white (6.5Y9.5/0.5) Round flow cassette provides comfortable 360 radial air distribution CEILING SUSPENDED UNIT, OPTIMIZED FOR SEASONAL EFFICIENCY FHQGC Seasonal efficiency, optimized for all seasons Smart design, new casing finished in fresh white (6.5Y9.5/0.5) VRV III HEAT PUMP 'High sensible mode': allows the VRV system to work with increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort All standard VRV III features VRV III HEATING ONLY Cost effective, low energy consumption heating system Lower CO 2 emmisions compared to traditional heating systems All standard VRV III features

6 NEW PRODUCTS 2011 VRV III HEAT PUMP, WITH CONNECTION TO STYLISH INDOOR UNITS Innovative VRV technology combined with stylish and silent indoor units Wide range of indoor units: combine VRV indoor units and stylish indoor units as Daikin Emura and Nexura in one system Up to 29 indoor units can be connected to a 18HP unit VRV IIIS HEAT PUMP Slim design for flexible installation Wide range of indoor units: either connect VRV or stylish indoor units: Daikin Emura, Nexura Up to 9 indoor units connectable All indoor units can be individually controlled 1.5 KW INDOOR UNITS Units especially developed for small or wellinsulated rooms, such as hotel bedrooms, small offices... Available as 4way blow cassette (FXZQ) and concealed ceiling unit (FXDQP7) 210 HEATING ONLY HYDROBOX FOR VRV VRV plug & play, all necessary components integrated Use heat pump technology to produce hot water Free hot water production possible FAN COIL UNIT 3X3 CASSETTE FWC air discharge Low power input thanks to DC fan motor Modern stylish decoration panel in white (RAL9010) Fresh air intake kit available

7

8 DAIKIN S 4 PILLARS

9 OF GROWTH AIR CONDITIONING REFRIGERATION HEATING APPLIED SYSTEMS THE LEADER IN PRODUCT QUALITY Daikin produces a highly energy efficient and comprehensive range of quality indoor climate control products and systems for commercial, residential and industrial applications. Our product portfolio is based on four distinct core pillars illustrating the diversification of Daikin: optimised heating solutions: air to air (residential and commercial application) & air to water (residential application with optional domestic hot water) state of the art direct expansion air conditioning for residential & commercial application applied systems for central cooling and heating for process and comfort application medium to low temperature refrigeration for retail environment Each pillar harnesses advanced technologies to deliver maximum energy efficiency and minimum energy consumption and running costs throughout the equipment life cycle. The width of our product range is also extensive and embracing in its coverage of these key indoor climate control disciplines to a point where we are confident of its ability to meet the requirements of our end user, specifier, contractor and installer customer base at all times. THE LEADER IN MANUFACTURING QUALITY AND CUSTOMER SERVICE Since our establishment in Ostend (Belgium) in 1972, we have updated and expanded our manufacturing facilities, including those opened in Milan (Italy), Plzen and Brno (Czech Republic) and through acquisitions in Cramlington (UK), Güglingen (Germany) and Cecchina (Italy), to a point where they are acknowledged as the most advanced in their field in Europe. Furthermore, all our plants benefit from our Japanese parent s policy of zero defect production, super efficient supply chain management and unrivalled research and development support. These substantial production facilities are underpinned by a network of wholly owned affiliate companies in the UK, France, Germany, Italy, Spain, Portugal, Poland, Greece, Belgium, The Netherlands, Sweden, Central Europe and South Africa, as well as numerous independent distributors throughout Europe, Africa and the Middle East supported by several offices in Ireland, Russia and Turkey. Experienced and professional support of this order enables us to maintain an enviably close relationship with international markets, tailor our product programme to suit precise regional requirements and respond quickly and efficiently to any area of potential market expansion.

10 HEATING & COOLING HEAT PUMP DAIKIN HEAT PUMPS: COMBINING EFFICIENCY AND TOTAL COMFORT At Daikin, we put our more than 50 years of experience in advanced heat pump technology at your service. Our new generation of heat pumps are allinone heating and cooling solutions for residential and commercial applications. They see to it that temperatures are comfortably warm in the winter and cool in summer. Because our systems extract thermal energy from the ambient air (socalled airtoair or airtowater heat pumps), they are far more energy efficient and emit far less CO 2 than comparable fossil fuel based boiler systems. + HOW ENERGY EFFICIENT ARE OUR HEAT PUMPS? A heat pump s efficiency is measured in COP (Coefficient of Performance) for heating and EER (Energy efficiency ratio) for cooling. Daikin s heat pumps achieve COPs and EERs of up to 4, meaning one unit of consumed energy yields 4 units of heated or cooled energy. HEAT RECOVERY HEAT PUMP OR HEAT RECOVERY SYSTEM? If you are looking for comfort solutions to heat and/or cool your shop, office or industrial building, we at Daikin have a lot to offer. Our highly efficient heat pumps can either heat or cool, while our heat recoveryequipped systems provide simultaneous heating and cooling, all from a single system. We offer numerous heat pumps and heat recovery systems to match your needs. They come in configurations from as small as 2kW for single room solutions, up to several MW s for large industrial applications. WHAT IS HEAT RECOVERY? Heat recovery is achieved by diverting exhaust heat from indoor units in cooling mode to areas requiring heating. Heat recovery in other words helps you reuse the energy available in one or more areas, and dispatch it to other areas in the same building. With a COP (Coefficient of Performance) up to 9, heat recovery systems achieve one of the highest energy efficiency s in the industry. 8

11 HEATING ONLY HIGHLY ENERGYEFFICIENT HEATING SOLUTIONS Thanks to its lead in heat pump technology, Daikin has made a remarkable contribution to the residential heating market: heat pump based heating systems that meet the demands of customers for less energygobbling systems and the demands of legislators for greater efficiency. The result: heating systems that are far more energy efficient than conventional fossil fuel solutions. This combination of advanced technology and renewable energy air as a fuel* places Daikin s role as technological leader in the service of preserving our environment. Add to this the famous Daikin reliability, flexibility, safety, low installation cost and the total comfort of its heating systems, and you know why Daikin is fast becoming a hot brand in the heating industry. *Daikin s heating systems also use a small amount of electricity (about 1/4 of the heating energy) COOLING ONLY COOL SOLUTIONS FOR YOUR INDUSTRY You place high demands concerning what s best for your business. We at Daikin have also been delivering stateoftheart cooling appliances for decades. Whether you are looking for optimal energyefficiency or for extreme precision for your industrial or process cooling, Daikin caters to your every cooling need. This unique dedication to technology and reliability makes Daikin your obvious choice. 9

12 ENVIRONMENTAL AWARENESS EU recognises heat pumps The approval of the Renewable Energy Directive by the European Parliament in December 2008 saw Daikin s efforts rewarded for designing energyefficient airtowater and airtoair heat pumps. In its quest for ever more energyefficient heating products, Daikin develops heat pumps that meet all the user s needs and consume considerably less primary energy than its fossilfuel based competitors. For the first time, the Directive recognises also aerothermal and hydrothermal energy as renewable energy sources. With the recognition by the EU of the outside air, ground and (surface, lake or well) water as renewable energy sources, much is expected of the member states promotion of heat pump technologies using these renewable energy sources. Alongside with solar panels and wind turbines, heat pumps may also be considered for subsidies, promotion campaigns and tax benefits. The goal of the EU is to increase the share of renewable energy in Europe to 20% by The urgency of the EU s 20/20/20 objectives reducing carbon emissions and energy consumption by 20% and increasing the share of renewable energy by 20%, all by 2020 and the fact that heat pumps can contribute directly to meeting these ambitious objectives, present a major opportunity for heat pumps. AEROTHERMAL HEAT PUMP HYDROTHERMAL HEAT PUMP GEOTHERMAL HEAT PUMP ENERGY EFFICIENT EQUIPMENT Many product innovations stem from Daikin environmental awareness. Inverter control reduces unit start up time and varies compressor output to match precise system load requirements. Also, when linked with Daikin DC compressor motors, it allows Daikin equipment to achieve the highest COP ratings in the market. Similarly, advanced computerised control packages ensure optimum system efficiency at all times and allow remote monitoring via the internet. REDUCING WASTE Daikin was the first European air conditioning manufacturer to gain ISO14001 environmental certification and all Daikin plants and subsidiaries are now similarly certified. The company s zero waste policy ensures that many of its manufacturing by products can be recycled, reused or recovered. RECYCLING MATERIALS Daikin recycles materials as a matter of course. For instance, the sludge recovered from pre treated waste water is used in cement manufacture. The recycling of other types of waste is also supported by investment in returnable packaging. 10

13 ECOLABEL BE/31/1 Over the past ten years, the "Flower" has become a Europeanwide symbol for products, providing simple and accurate guidance to consumers. All products bearing the "Flower" have been checked by independent bodies for complying with strict ecological and performance criteria. There are currently twentysix different product groups, and already more than 250 licences have been awarded for several hundred products. The EU Ecolabel is administered by the European Ecolabelling Board (EUEB) and receives the support of the European Commission, all Member States of the European Union and the European Economic Area (EEA). The Ecolabelling Board includes representatives such as industry, environment protection groups and consumer organisations. Heat pumps have recently been added as a product group and Daikin is the first company to obtain the Ecolabel for its Daikin Altherma air to water heat pumps. The EU awards a heat pump with an Ecolabel when they evaluate it to be more energy efficient compared to the average of heat pumps without Ecolabel. In being awarded the EU Ecolabel, Daikin Altherma was assessed in a range of categories: heating and cooling efficiency, refrigerant global warming potential (GWP), noise, absence of RoHS substances, training, documentation, availability of spare parts and detailed information at point of sale. Daikin Altherma represents the culmination of Daikin s decadeslong experience with heat pump technology. It efficiently extracts the low heat in the ambient air and raises it to temperatures capable of comfortably heating a house and providing domestic hot water in outdoor temperatures down to 20º C. In doing so, Daikin Altherma makes use of aerothermal energy, a renewable energy source. The heat pump technology employed is highly efficient (3 to 5 kwh of heat for every 1 kwh of electricity consumed). For certified models, please refer to WE CARE ICONS A NUMBER OF ICONS ARE HIGHLIGHTED IN GREEN TO INDICATE PRODUCT FEATURES THAT HAVE AN IMPACT ON REDUCING ENERGY CONSUMPTION. Energy efficiency Energy saving during standby mode Econo mode Two area intelligent eye Movement sensor Night set mode Fan only Autocleaning function Inverter technology

14 ENERGY LABELLING Energy labelling is part of a European Climate Change program, targeting energy efficiency as one method of reducing CO 2 emissions. The European Commission determines that improved awareness will enable users to purchase the most ecologically economic unit for their needs. Energy efficiency class of the unit in cooling mode: Energy efficiency class of the unit in heating mode: WHAT? The label provides information on air conditioning unit energy consumption. Units with cooling capacities up to 12kW are classified by energy consumption in categories from A to G and colour coded accordingly. The most energy efficient A category units are indicated by a dark green arrow and the least efficient G category units, by a red arrow. Thus users can compare the efficiencies of equal types of unit from different brands. WHAT IS LISTED ON THE LABEL Manufacturer s name and logo and type of indoor and outdoor units (*). A EER > 3.20 B 3.20 EER > 3.00 C 3.00 EER > 2.80 D 2.80 EER > 2.60 E 2.60 EER > 2.40 F 2.40 EER > 2.20 G 2.20 EER COP > COP > COP > COP > COP > COP > COP INDICATED ANNUAL ENERGY CONSUMPTION Approximate annual energy consumed is indicated, based on a standard residential model. Annual consumption is calculated by multiplying total power input by an average of 500 hr/year IN COOLING MODE AT FULL LOAD. Annual energy consumption cost is calculated by multiplying this figure by user s electricity tariff. COOLING OUTPUT Is the unit s cooling capacity in kw operating in cooling mode at full load. Users should select a unit with a rated output sufficient for their cooling/ heating requirements. Oversized units can increase on/off cycling, shortening service life and undersized units will not provide adequate cooling or heating. Output figures can be obtained from the manufacturer or local dealer. ENERGY EFFICIENCY RATIO (EER) Is the unit s cooling output divided by the total electrical power input required to deliver it the higher the EER, the greater the energy efficiency. TYPE Indicates whether the unit is a cooling only or cooling/heating model. Cooling mode indicates whether the unit is water or air cooled. HEAT OUTPUT Is the heating capacity of the unit in kw, operating in heating mode at full load. Energy Manufacturer Outside unit Inside unit More efficient Less efficient Annual energy consumption, kwh in cooling mode (Actual consumption will depend on how the apliance is used and climate) A B C D E F G Cooling output Energy efficiency ratio Full load (the higher the better) Type Cooling only Cooling + Heating Air cooled Water cooled Heat output Heating performance A: higher G: lower Noise (db(a) re 1 pw) kw kw * For multi models, Daikin indicates a single outdoor unit with a maximum of 2 wall mounted indoor units. Further information is contained in product brochures Airconditioner Energy Label Directive 2002/31/EC

15 SEASONAL EFFICIENCY With European legislation* pressing energy users to drastically cut energy consumption, improve energy efficiency of buildings and homes, and meet the Commission s 20/20/20 targets, industry is looking at more appropriate ways to evaluate efficiency. Thus, the EcoDesign Directive aims at reducing the environmental impact of products in the EU. To that end an implementing measure for air conditioners is under development and it will introduce a new method for performance specifications seasonal efficiency in replacement of the current method of nominal efficiency, which has its limitations. * EPB (Energy Performance of Buildings) Directive 2002/91/EC, ERP EcoDesign Directive Frequency Temperature distribution curve cooling NOMINAL EFFICIENCY OUTDATED Measuring energy performance is not new to Europe. Such measurements are used to provide consumers with information on air conditioner performance so they can make intelligent choices when purchasing. Present method in place is that of nominal efficiency, a method, however, with limitations that result in a significant gap between rated and actual performance. Current point for EER Outdoor temperature ( CDB) SEASONAL EFFICIENCY IN LINE WITH REALLIFE PERFORMANCE To correct this situation, a more complex calculation method seasonal efficiency is being developed simultaneously in EcoDesign and pren (inquiry version 2010). The major differences between seasonal and nominal calculation are: CAPACITY NOMINAL Temperature SEASONAL NOMINAL Capacity SEASONAL Auxiliary modes NOMINAL SEASONAL 1 Temperature condition: 35 C for cooling 7 C for heating Does not often occur in reality Several rating temperatures for cooling and heating, reflecting actual performance over an entire season Does not reflect partial capacity Benefits of inverter technology not visible Integrates operation at partial instead of full capacity Benefits of inverter technology are shown Does not take auxiliary power modes into account Includes consumption auxiliary modes: Thermostat off Standby mode OFF mode Crankcase heater Nominal efficiency gives an indication on how efficient an air conditioner operates at a nominal condition. Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire cooling or heating season. Defines a better representation of efficiency: seasonal efficiency Earliest implementation in EcoDesign Directive Today Daikin Actively contributes to the development of the EcoDesign methodology for air conditioners by sharing experience and technical knowledge. First to publish seasonal performance for residential and commercial air conditioners. First to integrate EcoDesign principle in the light commercial segment by launching Sky Air ranges optimized for seasonal efficiency.

16 DAIKIN SOLUTIONS TO R22 PHASE OUT Due to significant developments in heat pump technology, older systems of air conditioning run less efficiently than those available today. Furthermore the use of R22 will be soon banned in Europe. To upgrade R22 systems as cost effective as possible: Daikin developed solutions for its commercial range. Thanks to this new technology, it is possible to use existing R22piping. WHAT IS R22 AND WHY IS IT PHASEDOUT IN EUROPE? R22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. When R22 is released into the air, the ultraviolet rays of the sun cause it to decompose and chlorine is released in the stratosphere. Chlorine reacts with ozone, reducing the amount of the ozone. Due to ozone layer depletion, harmful ultraviolet rays reach the surface of the earth giving rise to a number of health and environmental issues. The international community therefore, signed the Montreal Protocol to phase out ozone depletion materials by The European Union however, decided to ban R22 already in WHEN WILL R22 BE BANNED IN EUROPE? Daikin advises to replace your existing R22 installation Ban on the use of R22 in new air conditioning equipment Ban on the use of virgin R22 for service & maintenance Ban on the use of all R22 for service & maintenance 1 Recycled: reuse of R22 following a basic cleaning process by the same undertaking that carried out the recovery (can be done by installer) Reclaimed: reprocessed R22 in order to meet the equivalent performance of virgin R22 (by specialized company) Only reclaimed & recycled 1 R22 allowed WHAT IS THE IMPACT ON AN R22 INSTALLATION? The R22 phaseout regulation will impact on all currently operating R22 systems, although reliable R22 equipment does not need to be replaced immediately because maintenance can be carried out with recycled or reclaimed R22 until January 1st, However, as currently not enough R22 is reclaimed to cover the demand, supply shortages and price increases are expected. If there is no reclaimed R22 available certain repairs (for example: compressor change) are no longer possible and considerable air conditioning system downtime can occur. It is therefore worthwhile to consider a replacement system before 2015, especially for air conditioning systems with a large impact on the daily running of the business. DAIKIN SOLUTIONS TO R22 PHASEOUT For Sky Air, reuse technology is available on Super Inverter, Seasonal Inverter and on the newly developed RZQGseries. Thanks to this technology these units can be installed using existing R22 piping. For VRV installations, VRV IIIQ solution allows retaining existing R22 piping and in some cases even the indoor units and controllers. 14

17

18 MCK75JVMK Ururu air purifier There are many substances in the air you breathe such as allergen, bacteria, virus and tobacco smoke, which causes your health to suffer. Above all things, dryness is especially a big issue during wintertime. Daikin Ururu Air Purifier moisturizes the air inside your home and relieves the effects of dry air. Just fill the 4l tank occasionally and it will humidify your room with a maximum volume of 600ml/h. This useful and innovative function stems from the incorporation of a slim line water tank and combined water wheel and vaporisation filter assembly. Humidification thanks to the slim water tank Air purification Daikin has already received great praise for its air purifiers: the Daikin TüV award confirms the efficiency of this unit. MCK75JVMK Indoor units MCK75JVMK Application Floor standing type Applicable room area m² 46 Casing Colour Black (N1) (Panel colour: silver) Dimensions Weight Fan Unit Unit Type HeightxWidthxDepth mm kg 590x395x Multi Blade Fan (Sirocco fan with shroud assembly) Air flow rate Air purifying operation Turbo/H/M/L/Silent Humidifying operation Turbo/H/M/L/Silent m³/h m³/h 450/330/240/150/60 450/330/240/150/120 Sound pressure Humidifying operation Air purifying operation Humidifying operation Power input Humidification Water tank capacity Turbo/H/M/L/Silent Turbo/H/M/L/Silent Turbo/H/M/L/Silent Turbo/H/M/L/Silent dba dba kw ml/h l 50/43/36/26/17 50/43/36/26/ /0.037/0.020/0.013/ /470/370/290/ Air filter Polypropylene net with catechin Air purifying operation Power input Turbo/H/M/L/Silent kw 0.081/0.035/0.018/0.011/0.008 Deodorizing method Flash streamer Titanium apatite photocatalytic filterdeodorising catalyst Dust collecting method Plasma ionizerelectrostatic dust collection filter Sign Dust: 3 stages, Odour: 3 stages, Air flow rate: auto/ll/l/m/h, Turbo mode HH, antipollen mode Off timer: 1/4/8h Cleaning: ionization/streamer Power supply Name / Phase / Frequency / Voltage Hz / V VM / 1~ / 50/60 / / Type Humidifying air purifier 16

19 humid air air Vaporization filter HOW DOES THE HUMIDIFICATION FUNCTION WORK? Water in the tank flows into the receiver tray housing the water wheel, which lifts the water as it rotates and releases it onto the filter. Air blown onto the filter, absorbs its moisture and discharges it into the room as humidification. MCK75JVMK Flash Streamer Highspeed electrons are generated by the Flash Streamer. These electrons powerfully break down odours and formaldehyde. Electrostatic dust collection filter Positively charged dust and pollen are adsorbed by the negatively charged filter. Titanium Apatite Photocatalytic Filter Odour, bacteria and viruses are adsorbed and decomposed. Deodorising catalyst Odours are adsorbed and broken down before the air is returned into the room. Dirty air Purified Air Prefilter (with catechin) Removes large dust particles and pet hairs. Flash Streamer unit Plasma ionizer Dust and pollen are positively charged and sent to the electrostatic filter. Daikin Ururu Air Purifier also removes efficiently allergens (e.g. pollen, house dust mites, dust, etc.), bacteria and viruses. Additionally, it has a high deodorizing efficiency; it eliminates efficiently tobacco smoke whilst decomposing other smells. It quickly collects particles and breaks them down rapidly. Its quiet operation makes it ideal for quiet nights. The unit includes seven pleated filters (one for immediate use and 6 spares). 17

20 MC707VMW MC707VMS Photocatalytic air purifier PURE AIR FOR FREE AND HEALTHY BREATHING stylish design improved performance unprecedented comfort super quiet operation easy to maintain portable no installation THREE TIMES PURIFICATION, A GOOD DEED FOR YOUR HEALTH Pollen, dust and pet hair are just some of the potential causes of allergies, asthma and respiratory problems. A Daikin air purifier cleans the air and relieves you of these troubles thanks to a threepart operation: allergen removal virus and bacteria removal odour removal Voluntary According TÜV NORD Systems GmbH & Co. KG Indoor to TÜV Air NORD Test Hygiene Standard Suitable for Allergic People House dust and indoor allergen retention Test object: Air purifier and humidifier SEGB2540/08 Daikin has already received great praise for its air purifiers: a UK allergy certificate and the Daikin TüV award confirm the efficiency of our units. MC707VM W/S Indoor units MC707VMS MC707VMW Application Desktop Type Applicable room area Capacity m² m³/min Casing Colour Silver White Dimensions Weight Fan Unit Unit Type HeightxWidthxDepth mm kg 533x425x Multi Blade Fan (Sirocco fan with shroud assembly) Air flow rate Air purifying operation Turbo/H/M/L/Silent m³/h 420/285/180/120/60 Sound pressure Air purifying operation Turbo/H/M/L/Silent dba 47/38/31/24/16 Air filter Polypropylene net with catechin Air purifying operation Power input Deodorizing efficiency (JEM 1467*) Dust collection efficiency Turbo/H/M/L/Silent Turbo Turbo kw % % 0.055/0.023/0.014/0.010/ Deodorizing method Deodorising catalyst Titanium apatite photocatalytic filter Flash streamer Bacteria filtering method Titanium apatite photocatalytic filter Bioantibody filter Flash streamer Dust collecting method Electrostatic dust collection filterplasma ionizer (electrostatic dust collection) Sign Dust: 3 stages, Odour: 3 stages, Air flow rate: auto/ll/l/m/h, Turbo mode HH, antipollen mode Off timer: 1/2/4h Maintenance: Wash/Filter exchange Power supply Name / Phase / Frequency / Voltage Hz / V VM / 1~ / 50/60 / / Type Photocatalytic Air Purifier 18

21 MC707VMW MC707VMS Prefilter (with catechin) Removes large dust particles and pet hairs. Bioantibody filter Airborne viruses are captured and removed. Plasma ionizer Dust and pollen are positively charged and sent to the electrostatic filter. Dirty air Flash Streamer unit Flash Streamer Electrostatic dust collection filter Highspeed electrons are Positively charged dust and generated by the Flash pollen are adsorbed by the Streamer. These electrons negatively charged filter. powerfully break down odours and formaldehyde. Front Deodorising catalyst Odours are adsorbed and broken down before the air is returned into the room. Purified air Back Titanium Apatite Photocatalytic Filter Odour, bacteria and viruses are adsorbed and decomposed. 19

22

23 People are becoming more and more aware of the cost of heating. Traditional heating systems and boilers use fossil fuels, making them an expensive and not sustainable option for the environment. Nobody wants to waste their money. Since approximately two thirds of the heat generated by the Daikin heat pump systems, is free of charge, the perfect solution is just around the corner. Moreover, since heat pumps consume less energy than traditional heating systems, they also generate less CO 2 emissions. Air to water and air to air heat pumps use energy from renewable sources: the ambient air. These energy sources are renewable and inexhaustible. Of course, heat pumps also need energy to function (mostly electricity), but increasingly this electricity can also be generated from renewable energy sources (solar energy, wind energy, hydropower, biomass) It is no surprise that people throughout Europe are becoming aware of new heating technology. In less than a decade practically all properly insulated buildings from Italy to Norway will be heated with heat pumps. Millions of heat pumps have already been installed in residential and commercial applications. So why wait? 95% of our air conditioning equipment can heat and/or cool and thus are heat pumps. The products in this chapter are optimised heating solutions as their primary scope and purpose is heating. HEATING NEW NEW NEW NEW NEW AIR TO WATER HEAT PUMPS 22 Daikin Altherma low temperature 24 EKHBH(X)B / ERHQBV3 26 EKHBH(X)B / ERHQBW1 27 EKHBH(X)B / ERLQBV3/CV3 28 EKHBH(X)B / ERLQCW1 29 EKHVH(X)B / ERHQBV3 30 EKHVH(X)B / ERHQBW1 31 EKHVH(X)B / ERLQBV3/CV3 32 EKHVH(X)B / ERLQCW1 33 EBHQBV3 35 ED(L/H)QB6V3 36 ED(L/H)QB6W1 37 EB(L/H)QB6V3 38 EB(L/H)QB6W1 39 Options 40 Daikin Altherma high temperature 44 EKHBRDAB / ERRQA 46 EKHBRDAB / ERSQA 47 Options 48 NEW NEW NEW Daikin Altherma for apartment buildings and collective housing 50 EKHVMR/YDA 52 EMRQAAY1 52 Options 53 Daikin heat pump convector 54 FWXVA 54 Domestic hot water heat pump 55 EKHVWQAV3 / EKHHSA1V3 55 AIR TO AIR HEAT PUMPS 56 Residential applications 57 FVXGK / RXGK 57 FTXLG / RXLG 59 VRV 60 RXHQP 60 RTSYQP 62 RWEYQPR 63 21

24 Air to water heat pumps DAIKIN ALTHERMA LOW TEMPERATURE SPLIT MONOBLOC HEATING APPLICATION New houses Together with existing boiler (bivalent) INSTALLATION OF HEAT PUMP 1 indoor unit 1 outdoor unit 1 outdoor unit HEATING EMITTERS Under floor heating Low temperature radiators Fan coil units Heat pump convector EXTRA COMFORT (OPTIONAL) Domestic hot water Cooling Solar connection for hot water production ADVANTAGES TOWARDS TRADITIONAL SYSTEMS Cost effective low energy consumption Reduced CO 2 emissions Full comfort 22

25 DAIKIN ALTHERMA HIGH TEMPERATURE DAIKIN ALTHERMA FOR APARTMENT BUILDINGS AND COLLECTIVE HOUSING DOMESTIC HOT WATER HEAT PUMP SPLIT Renovation: replacement of traditional boilers New construction buildings Replacement of domestic hot water tank 1 indoor unit 1 outdoor unit 1 outdoor unit Several indoor units 1 indoor unit High temperature radiators Under floor heating Low temperature radiators High temperature radiators Fan coil units Heat pump convector Not applicable Domestic hot water Solar connection for hot water production Domestic hot water Cooling Heat recovery Domestic hot water Cost effective low energy consumption Reduced CO 2 emissions Full comfort 23

26 Daikin Altherma low temperature split A SPLIT SYSTEM CONSISTS OF AN OUTDOOR UNIT AND AN INDOOR UNIT OUTDOOR UNIT: AN EFFICIENT USE OF ENERGY FROM THE AIR The outdoor unit extracts heat from the outside air and raises its temperature to a high enough to supply heating. This heat is then transferred to the indoor unit through refrigerant pipes (thus, the additional advantage is that the pipes can never freeze). The compact outdoor unit is easily installed and, as no drilling or excavation work is required, it can also be installed in flats and apartments. INDOOR UNIT: THE HEART OF THE DAIKIN ALTHERMA SYSTEM The indoor unit heats the water that circulates through under floor heating, heat pump convectors, low temperature radiators or regular fan coil units and also provides heat for domestic hot water. If you opt for the combination of heating and cooling, then the indoor unit can also decrease the water temperature to distribute a refreshing coolness. The indoor unit is available as floor standing model, but can also be supplied as wall mounted model to meet your client s needs. 1 / Solar collector 1 / Solar pump station Low temperature radiator 2 / Heat pump convector 1 / Solar kit Outdoor unit Under floor heating system Indoor unit 3 / Domestic hot water tank 1/ SOLAR SYSTEM To save even more energy on your domestic hot water production, the Daikin Altherma system can be connected to a solar system. The highefficiency collectors transfer all the shortwave solar radiation into heat as a result of their highly selective coating. The collectors can be mounted on the roof tiles. The solar kit controller and pump station provide the transfer of solar heat to the Daikin domestic hot water tank via an external heat exchanger. In contrast to tanks with two heat exchangers, this system allows the entire content of the tank to be efficiently heated with solar heat and, if necessary, with heat pump energy. When choosing for a split system, the solar kit can be installed in the indoor unit, which is even more space saving. If your customer prefers a monobloc system, a solar kit can be mounted on the domestic hot water tank (EKHWS and EKHWE) 2/ HEAT PUMP CONVECTOR The heat pump convector is much more than a fan coil unit or any other heat emitter. It can provide both heating and cooling if required and obtains optimal energy efficiency when connected to a Daikin Altherma low temperature system by approximately 25% in combination with under floor heating. 24

27 Daikin Altherma low temperature monobloc MONOBLOC: EVERYTHING COMBINED IN ONE OUTDOOR UNIT In addition to Daikin Altherma split systems, Daikin has introduced a monobloc version in which all hydraulic parts are located within the OUTDOOR UNIT. In this system, the water pipes, rather than the refrigerant pipes, run indoors from the outdoor unit, making installation much quicker and easier for the domestic installer. Available capacities for monobloc: 6,8 kw and 11,14,16 kw 1 / Solar collector 1 / Solar pump station Low temperature radiator 2 / Heat pump convector Under floor heating system 3 / Domestic hot water tank 1 / Solar kit Monobloc outdoor unit 3 / DOMESTIC HOT WATER TANK As for your domestic hot water, Daikin Altherma is just as clever. The unique layout and special placement of the components maximise energy efficiency. The water inside the storage tank is primarily warmed up by thermal energy from the outside air, thanks to the connection with the indoor unit. Furthermore, the indoor unit and domestic hot water tank can be stacked to save space or installed next to each other, if only limited height is available for installation. With a stainless steel finishing, the domestic hot water tank is available in 200l and 260l. If your client would require an enamelled domestic hot water tank, Daikin can offer you the EKHWE tank, available in 150, 200 and 300l. This tank also exists in a stainless steel finishing (EKHWS) 4 / ROOM THERMOSTAT With the wired or wireless room thermostat*, the ideal temperature can be easily, quickly and conveniently regulated. An external sensor (EKRTETS) can be placed between the under floor heating and the floor, as an option to the wireless room thermostat. It allows for more precise measurement and can regulate the comfort of your customer even more optimally and energy efficiently. *EKRTW for wired wall mounted and EKRTR for the wireless type. 25

28 EKHBH(X)B / ERHQBV3 Daikin Altherma low temperature split EKHBHXB ERHQ006008BV3 ERHQ011016BV3 Split system: wall mounted indoor unit and single phase outdoor unit Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Heating only Heating & Cooling Indoor units EKHBH008B EKHBX008B EKHBH016B EKHBX016B Casing Colour RAL9010 Material Epoxy polyester painted galvanised steel Dimensions Unit HeightxWidthx mm Depth 922x502x Operation range Cooling Heating Water Water Min.~Max. C Min.~Max. C side side 15~50 (9) 15~50 (9) 5~22 15~55 (9) 15~55 (9) 5~22 Sound power Medium speed 0 ESP dba Sound pressure Medium speed 0 ESP dba 28 Nominal flow dba 30 (3) / 29 (4) / 29 (5) 31 (6) / 29 (7) / 28 (8) High speed Nominal flow dba 32 (3) / 32 (4) / 31 (5) 33 (6) / 33 (7) / 32 (8) Outdoor units ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 Heating capacity Min. kw 4.36(1) 4.36(1) 4.36(1) 3.87(2) 3.87(2) 3.87(2) Nom. kw 5.75(1) 6.84(1) 8.43(1) 11.2 (1) 14.0 (1) 16.0 (1) 5.03(2) 6.10(2) 7.64(2) 10.3 (2) 13.1 (2) 15.2 (2) Max. kw 7.45(1) 8.79(1) 9.58(1) 6.68(2) 7.98(2) 8.76(2) Cooling capacity Min. kw 4.82(1) 4.82(1) 4.82(1) 3.62(2) 3.67(2) 3.67(2) Nom. kw 7.20(1) 8.16(1) 8.37(1) (1) (1) (1) 5.12(2) 5.86(2) 6.08(2) (2) (2) (2) Max. kw 7.20(1) 8.50(1) 8.91(1) 5.12(2) 6.13(2) 7.10(2) Power input Heating Nom. kw 1.26 (1) 1.58 (1) 2.08 (1) 2.46 (1) 3.17 (1) 3.83 (1) 1.58 (2) 1.95 (2) 2.54 (2) 3.06 (2) 3.88 (2) 4.66 (2) Cooling Nom. kw 2.27 (1) 2.78 (1) 2.97 (1) 3.79 (1) 5.78 (1) 6.77 (1) 2.16 (2) 2.59 (2) 2.75 (2) 3.60 (2) 5.29 (2) 5.95 (2) COP 4.56 (1) 3.18 (2) 4.34 (1) 3.13 (2) 4.05 (1) 3.00 (2) 4.55 (1) 3.37 (2) 4.42 (1) 3.38 (2) 4.18 (1) 3.26 (2) EER 3.17 (1) 2.94 (1) 2.82 (1) 3.67 (1) 2.99 (1) 2.63 (1) 2.37 (2) 2.26 (2) 2.21 (2) 2.78 (2) 2.36 (2) 2.20 (2) Dimensions Unit Height/Width/ mm Depth 735x825x300 Operation range Heating Min.~Max. CWB Cooling Min.~Max. CDB Domestic hot Min.~Max. CDB water 20~43 Charge kg Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V V3 / 1~ / 50 / 230 Current Recommended fuses A (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERHQ006BAV3 (4) In combination with ERHQ007BAV3 (5) In combination with ERHQ008BAV3 (6) In combination with ERHQ011BAV3 (7) In combination with ERHQ014BAV3 (8) In combination with ERHQ016BAV3 (9) 15 C 25 C BUH only, no heat pump operation = during commissioning 1,170x900x ~25 20~35 10~43 ~

29 EKHBH(X)B / ERHQBW1 Daikin Altherma low temperature split EKHBHX016B ERHQ011016BW1 Split system: wall mounted indoor unit and three phase outdoor unit Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Indoor units EKHBH016B EKHBX016B Casing Colour RAL9010 Material Epoxy polyester painted galvanised steel Dimensions Unit HeightxWidthx mm Depth 922x502x Operation range Heating Water Min.~Max. C side 15~55 (6) Cooling Water Min.~Max. C side 5~22 Sound power Medium speed 0 ESP dba 46 Sound pressure Medium speed 0 ESP dba 28 Nominal flow dba 31 (3) / 29 (4) / 28 (5) High speed Nominal flow dba 33 (3) / 33 (4) / 32 (5) Outdoor units ERHQ011BW1 ERHQ014BW1 ERHQ016BW1 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Cooling capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Heating Nom. kw 2.54 (1) 3.33 (1) 3.73 (1) 3.15 (2) 4.12 (2) 4.60 (2) Cooling Nom. kw 4.44 (1) 5.33 (1) 6.06 (1) 4.22 (2) 5.00 (2) 5.65 (2) COP 4.46 (1) 3.48 (2) 4.35 (1) 3.29 (2) 4.30 (1) 3.29 (2) EER 3.39 (1) 3.01 (1) 2.76 (1) 2.78 (2) 2.51 (2) 2.32 (2) Dimensions Unit HeightxWidthx mm Depth 1,345x900x Operation range Heating Min.~Max. CWB 20~35 Cooling Min.~Max. CDB 10~46 Domestic hot Min.~Max. CDB water 20~43 Charge kg 2.95 Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V W1 / 3N~ / 50 / 400 Current Recommended fuses A 20 notes: (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERHQ011BAW1 (4) In combination with ERHQ014BAW1 (5) In combination with ERHQ016BAW1 (6) 15 C 25 C BUH only, no heat pump operation = during commissioning 27

30 EKHBH(X)B / ERLQBV3/CV3 Daikin Altherma low temperature split EKHBHXB ERLQ006008BV3 ERLQ011016CV3 Split system: wall mounted indoor unit and single phase outdoor unit with bottom plate heater Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Indoor units Casing Colour Material Dimensions Unit HeightxWidthx mm Depth Operation range Heating Water Min.~Max. C side Cooling Water side Min.~Max. C Sound power Medium speed 0 ESP dba Sound pressure Medium speed 0 ESP dba Nominal flow dba High speed Nominal flow dba Heating only Heating & Cooling Heating only Heating & Cooling EKHBH008B EKHBX008B EKHBH016B EKHBX016B RAL9010 Epoxy polyester painted galvanised steel 922x502x ~50 (9) 15~55 (9) 5~22 5~ (3) / 29 (4) / 29 (5) 31 (6) / 29 (7) / 28 (8) 32 (3) / 32 (4) / 31 (5) 33 (6) / 33 (7) / 32 (8) Outdoor units Heating capacity Min. kw Nom. Max (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERLQ006BAV3 (4) In combination with ERLQ007BAV3 (5) In combination with ERLQ008BAV3 (6) In combination with ERLQ011CAV3 (7) In combination with ERLQ014CAV3 (8) In combination with ERLQ016CAV3 (9) 15 C 25 C BUH only, no heat pump operation = during commissioning kw kw Cooling capacity Min. kw Nom. Max. kw kw Power input Heating Nom. kw COP EER Cooling Nom. kw Dimensions Unit HeightxWidthx mm Depth Operation range Heating Min.~Max. CWB Cooling Min.~Max. CDB Domestic hot Min.~Max. CDB water Refrigerant Type Charge kg Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V Current Recommended fuses A ERLQ006BV3 ERLQ007BV3 ERLQ008BV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3 4.36(1) 3.87(2) 4.36(1) 3.87(2) 4.36(1) 3.87(2) 5.75(1) 5.03(2) 6.84(1) 6.10(2) 8.43(1) 7.64(2) 11.2 (1) 10.98(2) 14.0 (1) 13.1 (2) 16.0 (1) 15.2 (2) 7.45(1) 6.68(2) 8.79(1) 7.98(2) 9.58(1) 8.76(2) 4.82(1) 3.67(2) 4.82(1) 3.67(2) 4.82(1) 3.67(2) 7.20(1) 5.12(2) 8.16(1) 5.86(2) 8.37(1) 6.08(2) (1) (2) (1) ( (1) (2) 7.20(1) 5.12(2) 8.50(1) 6.13(2) 8.91(1) 7.10(2) 1.26 (1) 1.58 (2) 1.58 (1) 1.95 (2) 2.08 (1) 2.54 (2) 2.41 (1) 2.96 (2) 3.14 (1) 3.98 (2) 3.72 (1) 4.62 (2) 2.27 (1) 2.16 (2) 2.78 (1) 2.59 (2) 2.97 (1) 2.75 (2) 4.44 (1) 4.22 (2) 5.33 (1) 5.00 (2) 6.06 (1) 5.65 (2) 4.56 (1) 3.18 (2) 4.34 (1) 3.13 (2) 4.05 (1) 3.00 (2) 4.66 (1) 3.48 (2) 4.46 (1) 3.29 (2) 4.30 (1) 3.29 (2) 3.17 (1) 2.37 (2) 2.94 (1) 2.26 (2) 2.82 (1) 2.21 (2) 3.39 (1) 2.78 (2) 3.01 (1) 2.51 (2) 2.76 (1) 2.32 (2) 735x825x300 1,345x900x ~25 25~35 10~ ~ ~43 20~35 R410A V3 / 1~ / 50 /

31 EKHBH(X)B / ERLQCW1 Daikin Altherma low temperature split EKHBHX016B ERLQ011016CW1 Split system: wall mounted indoor unit and three phase outdoor unit with bottom plate heater Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Indoor units EKHBH016B EKHBX016B Casing Colour RAL9010 Material Epoxy polyester painted galvanised steel Dimensions Unit HeightxWidthx mm Depth 922x502x Operation range Heating Water Min.~Max. C side 15~55 (6) Cooling Water Min.~Max. C side 5~22 Sound power Medium speed 0 ESP dba 46 Sound pressure Medium speed 0 ESP dba 28 Nominal flow dba 31 (3) / 29 (4) / 28 (5) High speed Nominal flow dba 33 (3) / 33 (4) / 32 (5) Outdoor units ERLQ011CW1 ERLQ014CW1 ERLQ016CW1 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Cooling capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Heating Nom. kw 2.41 (1) 3.14 (1) 3.72 (1) 3.15 (2) 4.12 (2) 4.60 (2) Cooling Nom. kw 4.44 (1) 5.33 (1) 6.06 (1) 4.22 (2) 5.00 (2) 5.65 (2) COP 4.66 (1) 3.48 (2) 4.46(1) 3.29 (2) 4.30 (1) 3.29 (2) EER 3.39 (1) 3.01(1) 2.76 (1) 2.78 (2) 2.51 (2) 2.32 (2) Dimensions Unit HeightxWidthx mm Depth 1,345x900x Operation range Heating Min.~Max. CWB 25~35 Cooling Min.~Max. CDB 10~46 Domestic hot Min.~Max. CDB water 20~35 Charge kg 3.4 Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V W1 / 3N~ / 50 / 400 Current Recommended fuses A 20 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERLQ011CAW1 (4) In combination with ERLQ014CAW1 (5) In combination with ERLQ016CAW1 (6) 15 C 25 C BUH only, no heat pump operation = during commissioning 29

32 EKHVH(X)B / ERHQBV3 Daikin Altherma low temperature split EKHVHX016B ERHQ006008BV3 ERHQ011016BV3 Split system: floor standing indoor unit and single phase outdoor unit Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Heating only Heating & Cooling Indoor units EKHVH008B EKHVX008B EKHVH016B EKHVX016B Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Cooling Heating Water Water Min.~Max. C Min.~Max. C side side 15~50 (9) 15~50 (9) 5~22 15~55 (9) 15~55 (9) 5~22 Sound power Medium speed 0 ESP dba Sound pressure Medium speed 0 ESP dba 28 Nominal flow dba 30 (3) / 29 (4) / 29 (5) 31 (6) / 29 (7) / 28 (8) High speed Nominal flow dba 32 (3) / 32 (4) / 31 (5) 33 (6) / 33 (7) / 32 (8) Outdoor units ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERHQ011BAV3 ERHQ014BAV3 ERHQ016BAV3 Heating capacity Min. kw 4.36(1) 4.36(1) 4.36(1) 3.87(2) 3.87(2) 3.87(2) Nom. kw 5.75(1) 6.84(1) 8.43(1) 11.2 (1) 14.0 (1) 16.0 (1) 5.03(2) 6.10(2) 7.64(2) 10.3 (2) 13.1 (2) 15.2 (2) Max. kw 7.45(1) 8.79(1) 9.58(1) 6.68(2) 7.98(2) 8.76(2) Cooling capacity Min. kw 4.82(1) 4.82(1) 4.82(1) 3.62(2) 3.67(2) 3.67(2) Nom. kw 7.20(1) 8.16(1) 8.37(1) (1) (1) (1) 5.12(2) 5.86(2) 6.08(2) (2) (2) (2) Max. kw 7.20(1) 8.50(1) 8.91(1) 5.12(2) 6.13(2) 7.10(2) Power input Heating Nom. kw 1.26 (1) 1.58 (1) 2.08 (1) 2.46 (1) 3.17 (1) 3.83 (1) 1.58 (2) 1.95 (2) 2.54 (2) 3.06 (2) 3.88 (2) 4.66 (2) Cooling Nom. kw 2.27 (1) 2.78 (1) 2.97 (1) 3.79 (1) 5.78 (1) 6.77 (1) 2.16 (2) 2.59 (2) 2.75 (2) 3.60 (2) 5.29 (2) 5.95 (2) COP 4.56 (1) 3.18 (2) 4.34 (1) 3.13 (2) 4.05 (1) 3.00 (2) 4.55 (1) 3.37 (2) 4.42 (1) 3.38 (2) 4.18 (1) 3.26 (2) EER 3.17 (1) 2.94 (1) 2.82 (1) 3.67 (1) 2.99 (1) 2.63 (1) 2.37 (2) 2.26 (2) 2.21 (2) 2.78 (2) 2.36 (2) 2.20 (2) Dimensions Unit HeightxWidthx mm Depth 735x825x300 Operation range Heating Min.~Max. CWB Cooling Min.~Max. CDB Domestic hot Min.~Max. CDB water 20~43 Charge kg Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba 1,170x900x ~25 20~35 10~43 ~ Power supply Name / Phase / Frequency / Voltage Hz / V V3 / 1~ / 50 / 230 Current Recommended fuses A (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERHQ006BAV3 (4) In combination with ERHQ007BAV3 (5) In combination with ERHQ008BAV3 (6) In combination with ERHQ011BAV3 (7) In combination with ERHQ014BAV3 (8) In combination with ERHQ016BAV3 (9) 15 C 25 C BUH only, no heat pump operation = during commissioning 30

33 EKHVH(X)B / ERHQBW1 Daikin Altherma low temperature split EKHVHX016B ERHQ011016BW1 Split system: floor standing indoor unit and three phase outdoor unit Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Indoor units EKHVH016B EKHVX016B Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Heating Water Min.~Max. C side 15~55 (6) Cooling Water Min.~Max. C side 5~22 Sound power Medium speed 0 ESP dba 46 Sound pressure Medium speed 0 ESP dba 28 Nominal flow dba 31 (3) / 29 (4) / 28 (5) High speed Nominal flow dba 33 (3) / 33 (4) / 32 (5) Outdoor units ERHQ011BW1 ERHQ014BW1 ERHQ016BW1 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Cooling capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Heating Nom. kw 2.54 (1) 3.33 (1) 3.73 (1) 3.15 (2) 4.12 (2) 4.60 (2) Cooling Nom. kw 4.44 (1) 5.33 (1) 6.06 (1) 4.22 (2) 5.00 (2) 5.65 (2) COP 4.46 (1) 3.48 (2) 4.35 (1) 3.29 (2) 4.30 (1) 3.29 (2) EER 3.39 (1) 3.01 (1) 2.76 (1) 2.78 (2) 2.51 (2) 2.32 (2) Dimensions Unit HeightxWidthx mm Depth 1,345x900x Operation range Heating Min.~Max. CWB 20~35 Cooling Min.~Max. CDB 10~46 Domestic hot Min.~Max. CDB water 20~43 Charge kg 2.95 Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V W1 / 3N~ / 50 / 400 Current Recommended fuses A 20 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERHQ011BAW1 (4) In combination with ERHQ014BAW1 (5) In combination with ERHQ016BAW1 (6) 15 C 25 C BUH only, no heat pump operation = during commissioning 31

34 EKHVH(X)B / ERLQBV3/CV3 Daikin Altherma low temperature split EKHVHX016B ERLQ006008BV3 ERLQ011016CV3 Split system: floor standing indoor unit and single phase outdoor unit with bottom plate heater Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Heating only Heating & Cooling Indoor units EKHVH008B EKHVX008B EKHVH016B EKHVX016B Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Heating Water Min.~Max. C side 15~50 (9) 15~55 (9) Cooling Water Min.~Max. C side 5~22 5~22 Sound power Medium speed 0 ESP dba Sound pressure Medium speed 0 ESP dba Nominal flow dba High speed Nominal flow dba (3) / 29 (4) / 29 (5) 31 (6) / 29 (7) / 28 (8) 32 (3) / 32 (4) / 31 (5) 33 (6) / 33 (7) / 32 (8) Outdoor units Heating capacity Min. kw Nom. Max kw kw Cooling capacity Min. kw Nom. Max. kw kw Power input Heating Nom. kw COP EER Cooling Nom. kw Dimensions Unit HeightxWidthx mm Depth Operation range Heating Min.~Max. CWB Cooling Min.~Max. CDB Domestic hot Min.~Max. CDB water Refrigerant Type Charge kg Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name/Phase/Frequency/Voltage Hz/V Current Recommended fuses A ERLQ006BV3 ERLQ007BV3 ERLQ008BV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3 4.36(1) 3.87(2) 4.36(1) 3.87(2) 4.36(1) 3.87(2) 5.75(1) 5.03(2) 6.84(1) 6.10(2) 8.43(1) 7.64(2) 11.2 (1) 10.98(2) 14.0 (1) 13.1 (2) 16.0 (1) 15.2 (2) 7.45(1) 6.68(2) 8.79(1) 7.98(2) 9.58(1) 8.76(2) 4.82(1) 3.67(2) 4.82(1) 3.67(2) 4.82(1) 3.67(2) 7.20(1) 5.12(2) 8.16(1) 5.86(2) 8.37(1) 6.08(2) (1) (2) (1) ( (1) (2) 7.20(1) 5.12(2) 8.50(1) 6.13(2) 8.91(1) 7.10(2) 1.26 (1) 1.58 (2) 1.58 (1) 1.95 (2) 2.08 (1) 2.54 (2) 2.41 (1) 2.96 (2) 3.14 (1) 3.98 (2) 3.72 (1) 4.62 (2) 2.27 (1) 2.16 (2) 2.78 (1) 2.59 (2) 2.97 (1) 2.75 (2) 4.44 (1) 4.22 (2) 5.33 (1) 5.00 (2) 6.06 (1) 5.65 (2) 4.56 (1) 3.18 (2) 4.34 (1) 3.13 (2) 4.05 (1) 3.00 (2) 4.66 (1) 3.48 (2) 4.46 (1) 3.29 (2) 4.30 (1) 3.29 (2) 3.17 (1) 2.37 (2) 2.94 (1) 2.26 (2) 2.82 (1) 2.21 (2) 3.39 (1) 2.78 (2) 3.01 (1) 2.51 (2) 2.76 (1) 2.32 (2) 735x825x300 1,345x900x ~25 25~35 10~ ~ ~43 20~35 R410A V3 / 1~ / 50 / (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERLQ006BAV3 (4) In combination with ERLQ007BAV3 (5) In combination with ERLQ008BAV3 (6) In combination with ERLQ011CAV3 (7) In combination with ERLQ014CAV3 (8) In combination with ERLQ016CAV3 (9) 15 C 25 C BUH only, no heat pump operation = during commissioning 32

35 EKHVH(X)B / ERLQCW1 Daikin Altherma low temperature split EKHVHX016B ERLQ011016CW1 Split system: floor standing indoor unit and single phase outdoor unit with bottom plate heater Energy efficient heating and cooling system based on air source heat pump technology Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only Heating & Cooling Indoor units EKHVH016B EKHVX016B Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Heating Water Min.~Max. C side 15~55 (6) Cooling Water Min.~Max. C side 5~22 Sound power Medium speed 0 ESP dba 46 Sound pressure Medium speed 0 ESP dba 28 Nominal flow dba 31 (3) / 29 (4) / 28 (5) High speed Nominal flow dba 33 (3) / 33 (4) / 32 (5) Outdoor units ERLQ011CW1 ERLQ014CW1 ERLQ016CW1 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Cooling capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Heating Nom. kw 2.41 (1) 3.14 (1) 3.72 (1) 3.15 (2) 4.12 (2) 4.60 (2) Cooling Nom. kw 4.44 (1) 5.33 (1) 6.06 (1) 4.22 (2) 5.00 (2) 5.65 (2) COP 4.66 (1) 3.48 (2) 4.46(1) 3.29 (2) 4.30 (1) 3.29 (2) EER 3.39 (1) 3.01(1) 2.76 (1) 2.78 (2) 2.51 (2) 2.32 (2) Dimensions Unit HeightxWidthx mm Depth 1,345x900x Operation range Heating Min.~Max. CWB 25~35 Cooling Min.~Max. CDB 10~46 Domestic hot Min.~Max. CDB water 20~35 Charge kg 3.4 Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V W1 / 3N~ / 50 / 400 Current Recommended fuses A 20 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C (DT = 5 C) (3) In combination with ERLQ011CAW1 (4) In combination with ERLQ014CAW1 (5) In combination with ERLQ016CAW1 (6) 15 C 25 C BUH only, no heat pump operation = during commissioning 33

36

37 EBHQBV3 Daikin Altherma low temperature monobloc EBHQ006008BV3 Reversible monobloc H 2 O piping between outdoor unit and indoor heating appliances Freeze protection of hydraulic parts Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating & Cooling Outdoor units Heating capacity Nom. kw EBHQ006BAV (1) EBHQ008BAV (1) 5.03 (2) 7.64 (2) Cooling capacity Nom. kw 7.20 (1) 8.37 (1) 5.12 (2) 6.08 (2) Power input Cooling Nom. kw 2.27 (1) 2.97 (1) 2.16 (2) 2.75 (2) Heating Nom. kw 1.26 (1) 2.08 (1) 1.58 (2) 2.54 (2) COP 4.56 (1) 3.18 (2) 4.05 (1) 3.00 (2) EER 3.17 (1) 2.82 (1) 2.37 (2) 2.21 (2) Dimensions Unit HeightxWidthx mm Depth 805x1,190x Operation range Heating Ambient Min.~Max. CWB Water Min.~Max. C side 15~25 15~50 Cooling Ambient Min.~Max. CDB Water Min.~Max. C side 10~43 5~22 Domestic hot Ambient Min.~Max. CDB 15~35 water Water Min.~Max. C side 25~80 Charge kg 1.7 Sound power Heating Nom. dba Cooling Nom. dba 63 Sound pressure Heating Nom. dba Cooling Nom. dba Compressor Main power Name V3 component supply Phase 1 Frequency Hz 50 Voltage V 230 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C ( DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C ( DT = 5 C ) 35

38 ED(L/H)QB6V3 Daikin Altherma low temperature monobloc single phase ED(L/H)QB6V3 Heating only monobloc H 2 O piping between outdoor unit and indoor heating appliances Freeze protection of hydraulic parts Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only With bottom plate heater EDLQ011B6V3 EDLQ014B6V3 EDLQ016B6V3 Without bottom plate heater EDHQ011B6V3 EDHQ014B6V3 EDHQ016B6V3 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Heating Nom. kw 2.47 (1) 3.20 (1) 3.79 (1) 3.22 (2) 3.91 (2) 4.62 (2) COP 4.54 (1) 4.37 (1) 4.22 (1) 3.37 (2) 3.35 (2) 3.26 (2) Dimensions Unit HeightxWidthx mm Depth Hydraulic component Backup heater current Hz / V Type Power supply Phase / Frequency / Voltage Operation range Heating Ambient Min.~Max. CWB Water Min.~Max. C side 15~35 (3) 15~55 Domestic hot Ambient Min.~Max. CDB 15~43 (3) water Water Min.~Max. C side 25~80 Charge kg 2.95 Sound power Heating Nom. dba Sound pressure Heating Nom. dba Compressor Main power Name V3 component supply Phase 1~ Frequency Hz 50 Voltage V 230 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C ( DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C ( DT = 5 C ) (3) units with bottom plate heater down to 25 C 36 1,418x1,435x V3 1~ / 50 / 230

39 ED(L/H)QB6W1 Daikin Altherma low temperature monobloc three phase ED(L/H)QB6W1 Heating only monobloc H 2 O piping between outdoor unit and indoor heating appliances Freeze protection of hydraulic parts Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating only With bottom plate heater EDLQ011B6W1 EDLQ014B6W1 EDLQ016B6W1 Without bottom plate heater EDHQ011B6W1 EDHQ014B6W1 EDHQ016B6W1 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Heating Nom. kw 2.51 (1) 3.22 (1) 3.72 (1) 3.12 (2) 3.98 (2) 4.58 (2) COP 4.46 (1) 4.35 (1) 4.30 (1) 3.48 (2) 3.29 (2) 3.29 (2) Dimensions Unit HeightxWidthx mm Depth Hydraulic component Backup heater current Hz / V Type Power supply Phase / Frequency / Voltage Operation range Heating Ambient Min.~Max. CWB Water Min.~Max. C side 15~35 (3) 15~55 Domestic hot Ambient Min.~Max. CDB 15~43 (3) water Water Min.~Max. C side 25~80 Charge kg 2.95 Sound power Heating Nom. dba Sound pressure Heating Nom. dba Compressor Main power Name W1 component supply Phase 3N~ Frequency Hz 50 Voltage V 400 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C ( DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C ( DT = 5 C ) (3) units with bottom plate heater down to 25 C 37 1,418x1,435x W1 3~ / 50 / 400

40 EB(L/H)QB6V3 Daikin Altherma low temperature monobloc single phase EB(L/H)QB6V3 Reversible monobloc H 2 O piping between outdoor unit and indoor heating appliances Freeze protection of hydraulic parts Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating & Cooling With bottom plate heater EBLQ011B6V3 EBLQ014B6V3 EBLQ016B6V3 Without bottom plate heater EBHQ011B6V3 EBHQ014B6V3 EBHQ016B6V3 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Cooling capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Cooling Nom. kw 3.78 (1) 5.65 (1) 6.28 (1) 3.60 (2) 5.30 (2) 5.85 (2) Heating Nom. kw 2.47 (1) 3.20 (1) 3.79 (1) 3.22 (2) 3.91 (2) 4.62 (2) COP 4.54 (1) 3.37 (2) 4.37 (1) 3.35 (2) 4.22 (1) 3.26 (2) EER 3.39 (1) 2.83 (1) 2.66 (1) 2.78 (2) 2.36 (2) 2.24 (2) Dimensions Unit HeightxWidthx mm Depth Hydraulic component Backup heater current Hz / V Type Power supply Phase / Frequency / Voltage Operation range Heating Ambient Min.~Max. CWB Water Min.~Max. C side 15~35 (3) 15~55 Domestic hot Ambient Min.~Max. CDB 15~43 (3) water Water Min.~Max. C side 25~80 Charge kg 2.95 Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Compressor Main power Name V3 component supply Phase Frequency Hz 1~ 50 Voltage V 230 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C ( DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C ( DT = 5 C ) (3) units with bottom plate heater down to 25 C 38 1,418x1,435x V3 1~ / 50 / 230

41 EB(L/H)QB6W1 Daikin Altherma low temperature monobloc three phase EB(L/H)QB6W1 Reversible monobloc H 2 O piping between outdoor unit and indoor heating appliances Freeze protection of hydraulic parts Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Heating & Cooling With bottom plate heater EBLQ011B6W1 EBLQ014B6W1 EBLQ016B6W1 Without bottom plate heater EBHQ011B6W1 EBHQ014B6W1 EBHQ016B6W1 Heating capacity Nom. kw (1) (1) (1) (2) (2) (2) Cooling capacity Nom. kw (1) (1) (1) (2) (2) (2) Power input Cooling Nom. kw 3.78 (1) 5.32 (1) 6.06 (1) 3.60 (2) 4.98 (2) 5.65 (2) Heating Nom. kw 2.51 (1) 3.22 (1) 3.72 (1) 3.12 (2) 3.98 (2) 4.58 (2) COP 4.46 (1) 3.48 (2) 4.35 (1) 3.29 (2) 4.30 (1) 3.29 (2) EER 3.39 (1) 3.01 (1) 2.76 (1) 2.78 (2) 2.51 (2) 2.32 (2) Dimensions Unit HeightxWidthx mm Depth Hydraulic component Backup heater current Hz/V Type Power supply Phase / Frequency / Voltage Operation range Heating Ambient Min.~Max. CWB Water Min.~Max. C side 15~35 (3) 15~55 Domestic hot Ambient Min.~Max. CDB 15~43 (3) water Water Min.~Max. C side 25~80 Charge kg 2.95 Sound power Heating Nom. dba Cooling Nom. dba Sound pressure Heating Nom. dba Cooling Nom. dba Compressor Main power Name W1 component supply Phase Frequency Hz 3N~ 50 Voltage V 400 (1) cooling Ta 35 C LWE 18 C (DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 35 C (DT = 5 C) (2) cooling Ta 35 C LWE 7 C ( DT = 5 C); heating Ta DB/WB 7 C/6 C LWC 45 C ( DT = 5 C ) (3) units with bottom plate heater down to 25 C 39 1,418x1,435x W1 3~ / 50 / 400

42 EKHWSB Domestic hot water tank EKHWS Stainless steel domestic hot water tank Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Domestic hot water tank EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 Casing Colour Neutral white Material Epoxycoated mild steel Weight Unit Empty kg Tank Water volume l Material Stainless steel (DIN ) Maximum water temperature C 85 Heat exchanger Quantity Tube material 1 Duplex steel LDX 2101 Booster heater Capacity kw 3 1~ / 50 / 230 2~ / 50 / 400 EKHWEA Domestic hot water tank EKHWE200A Enameled domestic hot water tank Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Domestic hot water tank EKHWE150A3V3 EKHWE200A3V3 EKHWE300A3V3 EKHWE200A3Z2 EKHWE300A3Z2 Casing Colour RAL9010 Material Epoxy coated steel Weight Unit Empty kg Tank Water volume l Material Enamel coated steel (DIN4753TL2) Maximum water temperature C 75 Booster heater Capacity kw 3.0 1~ / 50 / 230 2~ / 50 /

43 EKRTR/EKRTW Room thermostat EKRTR EKRTW Heating and cooling mode, with possibility to disable cooling mode if not required Comfort function mode activates the programmed temperature s intended for a home occupied during the day; default setpoints are 21 C in heating mode and 24 C in cooling mode and can be changed by the user Reduced function mode activates the programmed temperature s for periods when the house is unoccupied or at night; default setpoints are 17 C in heating, 28 C in cooling mode and can be changed by the user Scheduled function mode: uses a timer to schedule heatin and cooling setpoints throughout the day; up to 12 setpoints can be programmed per day; the selected setpoints will be automatically activated at the scheduled time Holiday function mode: intended for setting reduced and fuelefficient setpoints when the house is unoccupied for long periods. The default setpoints are 14 C for heating and 30 C for cooling. Off function: switches the system off; however, the integrated frost protection remains activated (set by default at 4 C). Setpoint limitation sets the upper and lower setpoint limits within which the user can programme the desired comfort s and can only be modified by the installer Number of setpoint changes: 12/day Key lock function: possible to lock the keys of the room thermostat Wired room thermostat EKRTWA Dimensions Unit HeightxWidthx mm Depth 87x125x34 Weight Unit g 215 Ambient Storage Min./Max. C 20/60 temperature Operation Min./Max. C 0/50 Temperature Heating Min./Max. C 4/37 setting range Cooling Min./Max. C 4/37 Clock Yes Regulation function Proportional band Power supply Voltage V Battery powered 3* AALR6 (alkaline) Connection Type Wired Wireless room thermostat EKRTR1 Dimensions Receiver Thermostat HeightxWidthx HeightxWidthx mm mm Depth Depth 87x125x34 170x50x28 Weight Thermostat g 210 Receiver g 125 Ambient Storage Min./Max. C 20/60 temperature Operation Min./Max. C 0/50 Temperature Heating Min./Max. C 4/37 setting range Cooling Min./Max. C 4/37 Clock Yes Regulation function Proportional band Power supply Thermostat Voltage V Battery powered 3x AALRG (alkaline) Receiver Voltage V 230 Frequency Hz 50 Phase 1~ Connection Thermostat Wireless Receiver Wired Maximum distance Indoor m approx.30m to receiver Outdoor m approx.100m 41

44 EKSOLHW Solar connection EKSOL Connectable to solar collectors Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Solar connection Operation range Ambient Min.~Max. C temperature Sound pressure Nom. dba Thermal Zero loss collector efficiency η0 % performance Power supply intake EKSOLHWAV1 770x305x ~ ~ / 50 / Indoor unit EKSR3P Wired remote control for pump station EKSRDS1A Save energy and reduce CO 2 emissions with a solar system for domestic hot water production Wired remote control for pump station EKSRDS1A, connectable to pressurised solar system Pump station and control provide the transfer of solar heat to the domestic hot water tank Accessory EKSR3PA Mounting On wall 332x230x145 Thermal Zero loss collector efficiency η0 % performance Control Type Digital temperature difference controller with plain text display Power consumption W 2 Sensor Solar panel temperature sensor Pt1000 Storage tank sensor PTC Return flow sensor PTC Feed temperature and flow sensor Voltage signal (3.5V DC) Power supply Frequency / Voltage Hz / V 50 /

45 EKSV/HP Solar collector EKSV26P EKSH26P Vertical or horizontal solar collector for domestic hot water production Save energy and reduce CO 2 emissions with a solar system for domestic hot water production Easy to install Total solution for year round comfort Solar collector EKSV26P EKSH26P 2,000x1,300x85 1,300x2,000x85 43 Volume l Surface Outer m² Aperture m² Absorber m² Coating Microtherm (absorption max.96%, Emission ca. 5% +/2%) Absorber Harpshaped copper pipe register with laserwelded highly selective coated aluminium plate Glazing Single pane safety glass, transmission +/ 92% Allowed roof angle Min.~Max. 15~80 Operating Stand still Max. Max. bar C pressure temperature Thermal Zero loss collector efficiency η0 % 78.7 performance Heat loss coefficient a1 W/m².K 4,270 Temperature dependence of the W/m².K² heat loss coefficient a Thermal capacity kj/k 6.5 Incident angle AM at 50 modifier 0.94 Installed position Vertical Horizontal 43

46 Daikin Altherma high temperature split A SPLIT SYSTEM CONSISTS OF AN OUTDOOR UNIT AND AN INDOOR UNIT A1/ OUTDOOR UNIT: EFFICIENT USE OF ENERGY FROM THE AIR Daikin Altherma uses a natural source of energy. The outdoor unit extracts heat from the outside air and raises its temperature to a high enough to supply heating. This heat is transferred to the indoor unit via refrigerant piping. A2/ INDOOR UNIT: THE HEART OF THE DAIKIN ALTHERMA SYSTEM The indoor unit receives the heat from the outdoor unit and further increases the temperature, allowing water temperatures up to 80 C for heating through radiators and for domestic hot water use. Daikin s unique cascade compressor approach to the heat pumps (one in the outdoor unit/one in the indoor unit) means optimum comfort at even the coldest outdoor temperatures, without the need for an electric back up heater. 2 / User interface A1 / Outdoor unit 1 / Domestic hot water tank A2 / Indoor unit 44

47 EXTRA COMFORT 1/ DOMESTIC HOT WATER TANK: FOR LOW ENERGY CONSUMPTION Daikin Altherma s high water temperature is ideal for heating domestic hot water without the need for an additional electric heater. Rapid heating of domestic hot water also means smaller boilers are needed. For a family of approximately 4 people, the standard tank (EKHTS200A) is the best solution. Should you require more hot water, a larger tank is also available. 2/ USER INTERFACE With Daikin Altherma s user interface, the ideal temperature can be easily, quickly and conveniently regulated. It allows for more precise measurement and can regulate your comfort even more optimally and energy efficiently. HIGH TEMPERATURE ADVANTAGES > Heating up to 80 C without electric heater > Easy replacement of existing boiler, without changing heating pipes > Combinable with high temperature radiators 3/ HEATING AND DOMESTIC HOT WATER WITH SOLAR ENERGY The Daikin Altherma High Temperature heating system can optionally use solar energy for hot water production. If the solar energy is not required immediately, the purposebuilt hot water tank (EKHWP) can store large quantities of heated water for up to a day for later use as domestic hot water or for heating. > Low energy consumption: best COP s in its class (up to 3.08) 3/ Solar collector Indoor unit and Domestic hot water tank 45

48 EKHBRDAB / ERRQA Daikin Altherma high temperature split EKHBRDAB ERRQA High temperature application: up to 80 C without electric heater Single and three phase outdoor units with bottom plate heater Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Cost effective alternative to a fossil fuel boiler Easy to install Unit operation guaranteed down to 20 C Heating only Indoor units EKHBRD011ABV1 EKHBRD014ABV1 EKHBRD016ABV1 EKHBRD011ABY1 EKHBRD014ABY1 EKHBRD016ABY1 Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Heating Ambient Min.~Max. C Water Min.~Max. C side 20~20 25~80 Domestic hot Ambient Min.~Max. CDB 20~35 water Water Min.~Max. C side 25~80 Refrigerant Type R134a Charge kg 3.2 Sound pressure Nom. dba 43 (1) 46 (2) 45 (1) 46 (2) 46 (1) 46 (2) 43 (1) 46 (2) 45 (1) 46 (2) 46 (1) 46 (2) Night quiet Level 1 dba mode 40 (1) 43 (1) 45 (1) 40 (1) 43 (1) 45 (1) Power supply Name V1 Y1 Phase 1~ 3~ Frequency Hz 50 Voltage V Current Recommended fuses A (1) EW 55 C; LW 65 C; Dt 10 C; ambient conditions: 7 CDB/6 CWB (2) EW 70 C; LW 80 C; Dt 10 C; ambient conditions: 7 CDB/6 CWB (3) EW 30 C; LW 35 C; Dt 5 C; ambient conditions: 7 CDB/6 CWB Outdoor units ERRQ011AV1 ERRQ014AV1 ERRQ016AV1 ERRQ011AAY1 ERRQ014AAY1 ERRQ016AAY1 Heating capacity Nom. kw 11 (1) 14 (1) 16 (1) 11 (1) 14 (1) 16 (1) 11 (2) 14 (2) 16 (2) 11 (2) 14 (2) 16 (2) 11 (3) 14 (3) 16 (3) 11 (3) 14 (3) 16 (3) Power input Heating Nom. kw COP 3.57 (1) 4.40 (2) 2.61 (3) 3.08 (1) 2.50 (2) 4.22 (3) 4.66 (1) 5.65 (2) 3.55 (3) 3.00 (1) 2.48 (2) 3.94 (3) 5.57 (1) 6.65 (2) 4.31 (3) 2.88 (1) 2.41 (2) 3.72 (3) 3.57 (1) 4.40 (2) 2.61 (3) 3.08 (1) 2.50 (2) 4.22 (3) 4.66 (1) 5.65 (2) 3.55 (3) 3.00 (1) 2.48 (2) 3.94 (3) Dimensions Unit HeightxWidthx mm Depth 1,345x900x Operation range Heating Min.~Max. CWB 20~20 Domestic hot Min.~Max. CDB water 20~35 Charge kg 4.5 Sound power Heating Nom. dba Sound pressure Heating Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V V1 / 1~ / 50 / Y1 / 3~ / 50 / Current Recommended fuses A (1) 6.65 (2) 4.31 (3) 2.88 (1) 2.41 (2) 3.72 (3) 46

49 EKHBRDAB / ERSQA Daikin Altherma high temperature split EKHBRDAB ERSQA High temperature application: up to 80 C without electric heater Single and three phase outdoor units Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Cost effective alternative to a fossil fuel boiler Easy to install Unit operation guaranteed down to 20 C Heating only Indoor units EKHBRD011ABV1 EKHBRD014ABV1 EKHBRD016ABV1 EKHBRD011ABY1 EKHBRD014ABY1 EKHBRD016ABY1 Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Heating Ambient Min.~Max. C Water Min.~Max. C side 20~20 25~80 Domestic hot Ambient Min.~Max. CDB 20~35 water Water Min.~Max. C side 25~80 Refrigerant Type R134a Charge kg 3.2 Sound pressure Nom. dba 43 (1) 46 (2) 45 (1) 46 (2) 46 (1) 46 (2) 43 (1) 46 (2) 45 (1) 46 (2) 46 (1) 46 (2) Night quiet Level 1 dba mode 40 (1) 43 (1) 45 (1) 40 (1) 43 (1) 45 (1) Power supply Name V1 Y1 Phase 1~ 3~ Frequency Hz 50 Voltage V Current Recommended fuses A (1) EW 55 C; LW 65 C; Dt 10 C; ambient conditions: 7 CDB/6 CWB (2) EW 70 C; LW 80 C; Dt 10 C; ambient conditions: 7 CDB/6 CWB (3) EW 30 C; LW 35 C; Dt 5 C; ambient conditions: 7 CDB/6 CWB Outdoor units ERSQ011AAV1 ERSQ014AAV1 ERSQ016AAV1 ERSQ011AY1 ERSQ014AY1 ERSQ016AY1 Heating capacity Nom. kw 11 (1) 14 (1) 16 (1) 11 (1) 14 (1) 16 (1) 11 (2) 14 (2) 16 (2) 11 (2) 14 (2) 16 (2) 11 (3) 14 (3) 16 (3) 11 (3) 14 (3) 16 (3) Power input Heating Nom. kw COP 3.57 (1) 4.40 (2) 2.61 (3) 3.08 (1) 2.50 (2) 4.22 (3) 4.66 (1) 5.65 (2) 3.55 (3) 3.00 (1) 2.48 (2) 3.94 (3) 5.57 (1) 6.65 (2) 4.31 (3) 2.88 (1) 2.41 (2) 3.72 (3) 3.57 (1) 4.40 (2) 2.61 (3) 3.08 (1) 2.50 (2) 4.22 (3) 4.66 (1) 5.65 (2) 3.55 (3) 3.00 (1) 2.48 (2) 3.94 (3) Dimensions Unit HeightxWidthx mm Depth 1,345x900x Operation range Heating Min.~Max. CWB 20~20 Domestic hot Min.~Max. CDB water 20~35 Charge kg 4.5 Sound power Heating Nom. dba Sound pressure Heating Nom. dba Power supply Name / Phase / Frequency / Voltage Hz / V V1 / 1~ / 50 / Y1 / 3~ / 50 / Current Recommended fuses A (1) 6.65 (2) 4.31 (3) 2.88 (1) 2.41 (2) 3.72 (3) 47

50 EKHTSAC Domestic hot water tank EKHTS200A EKHTS260A High temperature application: up to 80 C without electric heater Stainless steel domestic hot water tank Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort Domestic hot water tank EKHTS200AC EKHTS260AC Casing Colour Metallic grey Material Galvanised steel (precoated sheet metal) Dimensions Unit HeightxIntegrated mm on indoor unitx WidthxDepth 1,335x2,010x600x695 1,335x2,285x600x695 Weight Unit Empty kg Heat exchanger Quantity Tube material 1 Duplex steel (EN ) Face area m² 1.56 Internal coil volume l 7.5 Power supply Phase Tank Water volume l Material Stainless steel (EN ) Maximum water temperature C 75 EKHWPA Domestic hot water tank EKHWPA Domestic hot water tank EKHWP300A EKHWP500A Casing Colour Dust grey (RAL7037) Material Impact resistant polypropylene Weight Unit Empty kg Heat exchanger Domestic hot Tube material Stainless steel (DIN ) water Face area m² Internal coil l volume Operating bar pressure 6 Average specifc W/K thermal output 2,795 2,860 Charging Tube material Stainless steel (DIN ) Face area m² Internal coil l volume Average specifc W/K thermal output , ,809 Auxiliary solar Tube material Stainless steel (DIN ) heating Face area m² 1.0 Internal coil l volume Average specifc W/K thermal output Power supply Phase Tank Water volume l Maximum water temperature C 85 48

51 EKSV/HP Solar collector EKSV26P EKSH26P Vertical or horizontal solar collector for domestic hot water production Save energy and reduce CO 2 emissions with a solar system for domestic hot water production Easy to install Total solution for year round comfort Solar collector EKSV26P EKSH26P 2,000x1,300x85 1,300x2,000x85 43 Volume l Surface Outer m² Aperture m² Absorber m² Coating Microtherm (absorption max.96%, Emission ca. 5% +/2%) Absorber Harpshaped copper pipe register with laserwelded highly selective coated aluminium plate Glazing Single pane safety glass, transmission +/ 92% Allowed roof angle Min.~Max. 15~80 Operating Stand still Max. Max. bar C pressure temperature Thermal Zero loss collector efficiency η0 % 78.7 performance Heat loss coefficient a1 W/m².K Temperature dependence of the W/m².K² heat loss coefficient a Thermal capacity kj/k 6.5 Incident angle AM at 50 modifier 0.94 Installed position Vertical Horizontal EKSRPS Solar connection EKSRPS3 Solar connection EKSRPS3 Control Type Digital temperature difference controller with plain text display Power consumption W Mounting On side of tank Sensor Solar panel temperature sensor Pt1000 Storage tank sensor PTC Return flow sensor PTC Feed temperature and flow sensor Voltage signal (3.5V DC) 49

52 Daikin Altherma for apartment buildings and collective housing EFFICIENT CLIMATE CONTROL FOR APARTMENT BUILDINGS Energy efficient heat pump technolgy The Daikin Altherma for apartment buildings and collective housing is today s answer to current and future issues associated with conventional heating systems such as increasing energy costs and unacceptable high environmental impact. With the Daikin Altherma for apartment buildings and collective housing, 2/3 of the heat generated comes from the air, recognised as renewable energy source, which is free of charge! Daikin Altherma achieves a typical seasonal COP of 3 in the moderate Western and central European climate. Compared to an oil boiler, this results in: Up to 36% less running costs* Up to 71% reduction of CO 2 emissions* Up to 35% reduction in primary energy use* * Data calculated taking in account Belgian conditions: SCOP of 3, average energy prices , CO2 emission factor for electricity production Modular system One or more invertercontrolled outdoor heat pump units can provide heating, cooling and domestic hot water to an apartment building, with 1 outdoor unit combined with up to 10 indoor units. Outdoor units between 23 and 45 kw extract the heat from the outdoor air, raise it to an intermediate temperature and transfer this heat energy to the individual indoor units. A small footprint indoor unit is installed in each individual dwelling. It receives the heat energy from the central outdoor unit, raises the temperature further by means of a second (cascading) heat pump cycle and feeds heated or cooled water to emitters (underfloor elements, heat pump convectors and/or radiators as needed). Two classes of indoor units are available (6 and 9 kw), ensuring optimum efficiency for any size apartment. Multiple outdoor units can be installed for larger applications. 3in1 system Daikin Altherma for apartment buildings and collective housing heats, cools, and produces domestic hot water: Heating: leaving water temperatures up to 80 C Cooling: leaving water temperatures down to 5 C Domestic hot water: tank temperatures up to 75 C Thanks to its heat recovery function, the system can heat up the domestic hot water tank up to 60 C with rejected heat from cooling operation. Fuel Condensing gas Daikin Altherma for apartment buildings and collective housing 120% 140% 120% 100% 120% 100% 80% 60% 40% 100% 100% 120% 100% 80% 82% 80% 92% 89% 60% 68% 60% 40% 40% 73% 20% 20% 20% 29% 0% 0% Running cost Primary energy Efficiency CO 2 emissions 0% 50

53 Daikin Altherma for apartment buildings and collective housing Concept description Outdoor One or more indoor and outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma for apartment buildings and collective housing Outdoor unit Indoor unit Heating/Cooling = + Hydro box Domestic hot water tank 1 or more outdoor units + several indoor units >> a modular system Modular system 1 APARTMENT TOTAL BUILDING 5.6kW 5.0kW 9kW 8kW 22.4kW 20kW 44.8kW 40kW Install separate outdoor units to reach higher capacities (Separate systems: the outdoor units are not connected to each other) 1P, 230V 3P, 400V Note: Heating capacities 7 C ambient temperature, Cooling capacities 35 C ambient temperature 51

54 EKHVMR/YDA Daikin Altherma for apartment buildings and collective housing indoor unit High temperature application: up to 80 C without electric heater Possible to choose between low temperature and high temperature heat emitters Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Heating and cooling in one system Indoor units EKHVMRD50A EKHVMRD80A EKHVMYD50A EKHVMYD80A Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit HeightxWidthx mm Depth 705x600x Operation range Heating Ambient Min.~Max. C Water Min.~Max. C side 15~20 25~80 Cooling Ambient Min.~Max. CDB Water Min.~Max. C side 10~43 5 (3)~20 (3) Domestic hot Ambient Min.~Max. CDB 15~35 water Water Min.~Max. C side 45~75 Refrigerant Type R134a Charge kg 2 Sound pressure Nom. dba 40 (1) 43 (2) 42 (1) 43 (2) 40 (1) 43 (2) 42 (1) 43 (2) Night quiet Level 1 dba mode 38 (1) Power supply Name V1 Phase 1~ Frequency Hz 50 Voltage V Current Recommended fuses A 20 (1) Sound s are measured at: EW55 C; LW65 C (2) Sound s are measured at: EW70 C; LW80 C (2) Cooling leaving water temperature depends on indoor unit operation status and other setpoints Heating only EKHVM(R/Y)DA Heating & Cooling EMRQA Daikin Altherma for apartment buildings and collective housing outdoor unit The ultimate flexible heating solution for apartment buildings and collective housing Customised to meet your building s needs: 10 indoor units to be connected to 1 outdoor unit Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy installation and maintenance Integrated heat recovery system Heating & Cooling EMRQ1416AAY1 Outdoor units EMRQ8AAY1 EMRQ10AAY1 EMRQ12AAY1 EMRQ14AAY1 EMRQ16AAY1 Heating capacity Nom. kw 22.4 (1) 28 (1) 33.6 (1) 39.2 (1) 44.8 (1) Cooling capacity Nom. kw 20 (2) 25 (2) 30 (2) 35 (2) 40 (2) Dimensions Packed unit Unit HeightxWidthx HeightxWidthx mm mm Depth Depth 1,680x1,300x765 1,885x1,425x Liquid Quantity/Type/OD mm 1/Braze connection/9.52 1/Braze connection/12.7 connections Suction Quantity/Type/OD mm 1/Braze connection/19.1 1/Braze connection/22.2 1/Braze connection/28.6 High and low Quantity/Type/OD mm pressure gas 1/Braze connection/15.9 1/Braze connection/19.1 1/Braze connection/22.2 Gas Type Discharge gas Type Drain Quantity (1) Condition: Ta=7 CDB/6 CWB, 100% connection ratio (2) Condition: Ta=35 CDB, 100% connection ratio 52

55 EKHTSAB Domestic hot water tank EKHTS200AB High temperature application: up to 80 C without electric heater Stainless steel domestic hot water tank Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort Domestic hot water tank EKHTS200AB EKHTS260AB Casing Colour Metallic grey Material Galvanised steel (precoated sheet metal) Dimensions Unit HeightxIntegrated mm on indoor unitx WidthxDepth 1,335x2,010x600x695 1,335x2,285x600x695 Weight Unit Empty kg Tank Water volume l Material Stainless steel (DIN ) Maximum water temperature C 75 Heat exchanger Quantity Tube material 1 Duplex steel LDX 2101 Face area m² 1.56 Internal coil volume l

56 FWXVA Heat pump convector FWXVA ARC452A15 Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room Energy efficient heating and cooling system based on air souce heat pump technology Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air Optimum energy efficiency when connected to a Daikin Altherma low temperature system Reduced running costs Extremely quiet in operation: down to 19dBA sound pressure Ideal for installation beneath a window Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Indoor unit silent operation: silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Can be installed against a wall or recessed Powerful mode can be selected for rapid cooling; after the powerful mode is turned off, the unit returns to the preset mode. Heating & Cooling Indoor units FWXV15AVEB FWXV20AVEB Heating capacity Total capacity Nom. kw Cooling capacity Total capacity Nom. kw Sensible Nom. kw capacity Power input Heating Nom. kw Cooling Nom. kw Dimensions Unit HeightxWidthx mm Depth 600x700x Drain/OD/Inlet/Outlet mm/inch connections 18/G 1/2/G 1/2 Sound pressure Heating Nom. dba Cooling Nom. dba ~ / 50/60 / /220 (1) Cooling: indoor temp. 27 CDB, 19 CWB; entering water temp. 7 C, water temperature rise 5K. (2) Heating: room temperature 20 CDB and entering water temperature 45 C, water temperature drop 5K. 54

57 EKHVWQAV3 / EKHHSA1V3 Domestic hot water heat pump Domestic hot water production adapted to your needs Short heatup time thanks to the use of inverter technology Save up to 65% in CO 2 emmissions compared to electrical systems Corrosion protection: low maintenance, highquality stainless steel tank Indoor unit * EKHVWQ002AAV3 Heating capacity Nom. kw 2.5 COP Casing Colour 4.20(1) / 3.50(2) / 2.00(3) / 2.45 (4) Metallic grey Material Galvanised steel (precoated sheetmetal) 730x600x595 Domestic hot Ambient Min.~Max. CDB 2~35 water Water Min.~Max. side C 35~60 (HP only) / 35~75 (HP + BSH) Refrigerant Type R410A Charge kg Sound pressure Nom. dba 47 Night quiet mode Level dba 43 1~ / 50 / 230 (1) heatup COP 15 C~50 C according to EN2553, Tambient = 15 C with Heat pump only (2) heatup COP 15 C~60 C according to EN2553, Tambient = 15 C with Heat pump only (3) tapping COP according to pren2553, Tambient = 15 C in combination with 200l (4) tapping COP according to pren2553, Tambient = 15 C in combination with 260l tank Domestic hot water tank *EKHHS200AA1V3 *EKHHS260AA1V3 Installation place indoor only (1) Casing Colour Metallic grey Material Sheet metal Dimensions Unit HeightxWidthx mm Depth 1,235x585x732 1,510x585x732 Tank Water volume l Equivalent hot water volume Material Maximum water temperature C Power supply Name / Phase / Frequency / Voltage Hz / V (1) set temperature: 40 C (2) set temperature: 50 C (3) set temperature: 60 C (1) / 255 (2) / 320 (3) 250(1) / 330(2) / 415(3) V3 / 1~ / 50 / *Note: grey cells contain preliminary data

58 Air to air heat pumps Pure comfort Daikin introduces Nexura COMFORT IS KEY radiant heat Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling of wellbeing to your living space all year round. Its unobtrusive yet stylish design with a front panel that radiates additional heat, its low noise and reduced air flow turn your room into a haven. 56

59 FVXGK / RXGK Floor standing unit with radiant heat panel FVXG25,35,50K RXG25,35K Energy efficient units: full range A class energy labels The front panel of the indoor unit radiates additional heat to add to your comfort on cold days Whisper quiet operation: down to 19dBA sound pressure Comfortable vertical auto swing ensures draughtfree operation and prevents ceiling soiling Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Ideal for installation beneath a window ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Can be installed against a wall or recessed Heating & Cooling Indoor units Cooling capacity Min./Nom./Max. kw Heating capacity Min./Nom./Max. kw Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour White Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom/Low/Silent dba Heating High/Nom/Low/ dba Silent/Radiant 39/32/26/22/19 40/33/27/23/19 46/40/34/30/26 connections Gas OD mm Drain OD mm Outdoor units Sound power Cooling Nom./High dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~18 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m *pren14825 (inquiry version 2010) *FVXG25K *FVXG35K *FVXG50K 1.3/2.5/ /3.5/ /5.0/ /3.4/ /4.5/ /5.8/ x950x /32/26/23 39/33/27/24 44/40/36/ ~ / 50 / *RXG25K *RXG35K *RXG50K 550x828x x901x /61 /63 /62 46/43 48/44 47/44 48/45 10~ ~ / 50 / *Note: grey cells contain preliminary data

60 Ultra efficient home heating comfort Residents of cold climates are increasingly turning to home heating systems offering high heating capacities while saving on energy consumption. Thanks to the integration of its highend technologies, Daikin s FTXLG offers just that combination and much more: the guarantee of optimal indoor climate comfort even at outdoor temperatures of 20 C. Heating or cooling, the FTXLG heat pump based system does it all, efficiently and intelligently. BUILTIN INTELLIGENCE 2 area intelligent eye With this function, the air flow is sent to a zone other than where the person is located at that moment. If two people are detected in the room, the movement sensor, together with the comfort mode (heating directed at the floor, cooling directed at the ceiling), will see to it that the air flow is projected away from the occupants. If no people are detected, the unit will automatically switch over to the energyefficient setting. Remote control The infrared remote control with weekly timer has a very stylish design, is userfriendly and equipped with a weekly timer. With this timer, you can programme a 7day schedule with 4 different actions per day. Furthermore, the convenient copy function allows you to very quickly copy any day s programme to one or more other days. Should there be a malfunction in the air conditioner, you can read the code on the LCD screen of the remote control and easily find the appropriate solution. ARC452A3 Energy saving during operation standby Once the standby currentsaving function has been activated, the current consumption when operating on standby will be reduced by about 80%. If no people are detected for an extended period of time, i.e. more than 20 minutes, the system will automatically switch to the currentsaving mode. 58

61 FTXLG / RXLG Wall mounted unit FTXL20,25,35G RXL20,25G ARC452A3 Optimised heating solution for your home Energy efficient: full range A class energy labels (COP = 4.58) High heating capacity: up to 6.6 kw Extended operation range for heating down to 20 C Weekly timer: allows to program the unit on a weekly basis 2 area intelligent eye: air flow is sent to the area in a room where no person is detected Energy saving during standby mode: reduction of energy from 10W to 2W ECONO mode decreases power consumption so that other appliances that need large power supply can be used Night set mode saves energy by preventing overcooling or overheating during night time Comfort mode guarantees draught free operation Powerful mode can be selected for rapid cooling or heating Whisper quiet operation: down to 23 dba sound pressure Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dBA Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses 3D air flow combines vertical and horizontal autoswing to circulate a stream of warm/cool air right to the corners of even large spaces Heating & Cooling Indoor units FTXL20G FTXL25G FTXL35G Cooling capacity Min./Nom./Max. kw 1.4/2.0/ /2.5/ /3.5/5.3 Heating capacity Min./Nom./Max. kw 1.4/2.7/ /3.4/ /4.0/6.6 Power input Cooling Min./Nom./Max. kw 0.35/0.45/ /0.55/ /0.87/1.81 Heating Min./Nom./Max. kw 0.34/0.59/ /0.77/ /0.92/2.01 EER COP Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour White Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low/ dba Silent operation Heating High/Nom./Low/ Silent operation dba 42/36/29/26 42/38/33/30 44/39/34/31 connections Gas OD mm Drain OD mm Outdoor units RXL20G RXL25G RXL35G 550x765x x825x300 Fan Air flow rate Cooling High/Low m³/min Heating High/Low m³/min Sound power Cooling Nom. dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20~20 connections length Max. OU IU m Level difference IU OU Max. m Heat insulation Total piping length System Actual m 295x800x /34/26/23 42/38/33/30 43/39/34/ ~ / 50 / / / / / / / /44 48/45 10~ Both liquid and gas pipes 1~ / 50 /

62 RXHQP VRV III Heating only RXHQ444648P Cost effective, low energy consumption heating system Lower CO 2 emmisions compared to traditional heating systems Integrate temperature control, fresh air provision, Biddle air curtains and the production of hot water in one total solution system Easy installation thanks to automatic refrigerant charging and automatic testing Easy compliance with Fgas regulation thanks to automated refrigerant containment check Flexible combination of outdoor units Compact size leaves maximum floorspace High external static pressure (up to 78.4Pa) allows indoor installation Night quiet mode in two steps: step 1: 50 dba, step 2: 45 dba Wide piping flexibility: maximum piping length: 165m, total piping length: 1,000m All indoor units can be individually controlled Phased installation possible Wide outdoor unit range: from 5 to 54HP via 1 single refrigerant circuit Wide range of indoor units: 15 different models in a total of 76 variations 60

63 Heating only Outdoor system *8 *10 *12 *14 *16 *18 Capacity range HP Heating capacity Nom. kw Power input 50Hz Heating Nom. kw COP Maximum number of connectable indoor units ,680x930x765 1,680x1,240x Operation range Heating Min.~Max. CWB 20.0~15.0 connections Gas OD mm Total piping length System Actual m 1,000 Level difference OU IU m 50 (outdoor unit in highest position) (optional: 90) 3N~ / 50 / 400 Outdoor system *20 *22 *24 *26 *28 *30 *32 *34 *36 System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P Outdoor unit module 2 RXHQ12P RXHQ18P Capacity range HP Heating capacity Nom. kw Power input 50Hz Heating Nom. kw COP Maximum number of connectable indoor units Operation range Heating Min.~Max. CWB 20.0~15.0 connections Gas OD mm Total piping length System Actual m Level difference OU IU m 50 (outdoor unit in highest position) (optional: 90) ,000 3N~ / 50 / 400 Outdoor system *38 *40 *42 *44 *46 *48 *50 *52 *54 System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P Outdoor unit module 2 RXHQ12P RXHQ18P Outdoor unit module 3 RXHQ18P Capacity range HP Heating capacity Nom. kw Power input 50Hz Heating Nom. kw COP Maximum number of connectable indoor units 64 Operation range Heating Min.~Max. CWB 20.0~15.0 connections 19.1 Gas OD mm 41.3 Total piping length System Actual m 1,000 Level difference OU IU m 50 (outdoor unit in highest position) (optional: 90) 3N~ / 50 / *Note: grey cells contain preliminary data

64 RTSYQP VRV III heat pump, optimised for heating RTSYQ1416P First system in the industry developed for heating operation in low ambient conditions, making it suitable for single source heating Extended operation range for heating down to 25 CWB 50 HEATING VRV IIIC CWB VRV III CWB CWB 25 High COP values at low ambients due to the use of two stage compression technology (COP values of 3.0 and more at 10 C) Improved comfort s because of shorter defrost time Shorter heat up time compared to standard VRV III heat pump Easy installation thanks to automatic refrigerant charging operation, automatic test operation Connectable to all VRV indoor units, ventilation and Control systems. Heating & Cooling Outdoor system RTSYQ10P RTSYQ14P RTSYQ16P RTSYQ20P System Outdoor unit module 1 RTSQ10P RTSQ14P RTSQ16P RTSQ8P Outdoor unit module 2 RTSQ12P Function unit BTSQ20P Capacity range HP Cooling capacity Nom. kw 28.0 (1) 40.0 (1) 45.0 (1) 56.0 (1) Heating capacity Nom. kw 31.5 (2) 45.0 (2) 50.0 (2) 63.0 (2) 28.0 (3) 40.0 (3) 45.0 (3) 56.0 (3) Power input 50Hz Cooling Nom. kw Heating Nom. kw EER COP 3.54 (1) 4.09 (2) 3.17 (1) 3.98 (2) 3.02 (1) 3.88 (2) 3.64 (1) 4.12 (2) Maximum number of connectable indoor units Sound power Cooling Nom. dba Sound pressure Cooling Max./Nom. dba 62/60 63/61 65/63 Operation range Cooling Min.~Max. CDB 5~46 Heating Min.~Max. CWB 25~15.5 connections 25 CWB Gas OD mm Oil equalizing OD mm 19.1 Total piping length System Actual m 500 Level difference OU IU m 50 (outdoor unit in highest position) 3~ / 50 / (1) Cooling: Indoor temp. 27 CDB, 19 CWB / outdoor temp. 35 CDB / equivalent piping length: 7.5m / difference: 0m / function unit length: 6m / combined indoor unit: FXFQ50P x 5 units (2) Heating: Indoor temp. 20 CDB / outdoor temp. 7 CDB,6 CWB / equivalent piping length: 7.5m / difference: 0m / function unit length: 6m / combined indoor unit: FXFQ50P x 5 units (3) Heating: Indoor temp. 20 CDB / outdoor temp. 10 CWB / equivalent piping length: 7.5m / difference 0m / function unit length: 6m / combined indoor unit: FXFQ50P x 5 units Outdoor unit module RTSQ8P RTSQ10P RTSQ12P RTSQ14P RTSQ16P BTSQ20P 1,680x930x765 1,680x1,240x765 1,570x460x ~ / 50 /

65 RWEYQPR VRV III water cooled geothermal series RWEYQ10PR Reduced CO 2 emmisions thanks to the use of geothermal energy as a renewable energy source No need for an external heating or cooling source Extended operation range (inlet water temperature) down to 10 C in heating mode High heating efficiency at low water entering temperatures (eg COP at 10 C entering water temperature for an 8HP unit) Suitable for multistorey and large buildings because of the hardly unlimited possibilities of water piping Simultaneous cooling and heating operation from one system 1 High sensible mode, allows the VRV system to work with increased sensible capacity in cooling mode resulting in higher efficiency and improved comfort 2stage heat recovery: first stage between indoor units 1, second stage between outdoor units thanks to the storage of energy in the water circuit Heat recovery systems offer the highest comfort, including individual changeover of each BS box without disruption of other BS boxes 1 Wide range of indoor units: 15 different models in a total of 76 variations Compact design (stacked configuration possible) Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager, BACnet Gateway, DMSIF Heat pump operation Heat recovery Heating & Cooling Outdoor units RWEYQ8PR RWEYQ10PR System Outdoor unit module 1 RWEYQ8PR RWEYQ10PR Cooling capacity Nom. kw Heating capacity Nom. kw Power input 50Hz Cooling Nom. kw Heating Nom. kw EER COP Maximum number of connectable indoor units ,000x780x Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Inlet water Cooling Min.~Max. CDB 6~45 temperature Heating Min.~Max. CWB 10~45 connections Gas OD mm Discharge gas OD mm Total piping length System Actual m Level difference OU IU m (1) In case of heat pump system, gas pipe is not used (2) In case of heat recovery system (3) In case of heat pump system * Contact your local dealer for more information (1) 22.2 (1) 15.9 (2) 19.1 (2) 19.1 (3) 22.2 (3) 300 * 3~ / 50 /

66

67 With air conditioning, you treat the air in a room to obtain an ideal temperature, purity, ventilation and humidity. Air conditioning does much more than just cool the space you live and work in. Enjoy perfect Daikin comfort all year round. AIR CONDITIONING Residential applications 67 Light commercial applications 115 VRV 167 Ventilation & Biddle Air Curtains 213 Marine types

68

69 NEW NEW NEW NEW NEW NEW NEW NEW RESIDENTIAL APPLICATIONS Benefits overview 68 PAIR APPLICATIONS Wall mounted units 73 FTXRE / RXRE 73 FTXGJ / RXGK 75 FTXLG / RXLG 76 FTXSJ/G / RXSJ/F 77 FTXJV/GV / RXJV/GV 78 Concealed ceiling units 79 FDXSE/C / RXSJ/G 79 Floor standing units 81 FVXGK / RXGK 81 FVXSF / RXSJ 82 Flexi type unit 83 FLXSB / RXSJ 83 MULTI MODEL APPLICATIONS 85 MXUG 86 MXSE/F/G/H 88 RXYSQP8V1 109 For more information on Options & Control Systems, please refer to page 274 of this catalogue. 67

70 Benefits overview Split We care icons Comfort FTXRE FTXGJ RXGK CTXUG MXUG FTXLG Wall mounted unit FTXSJ RXLG RXSJ FTXSG RXSG FTXJV FTXGV RXGV Preliminary info For explanation on the benefits, see flap in the backcover of this catalogue. 68

71 Air flow Humidity control Air treatment Remote control & timer Other funtions

72 Benefits overview Split We care icons Comfort FVXGK Floor standing unit FVXSF RXGK RXSJ FDXSE RXSJ Concealed ceiling unit FDXSC FDBQB RXSJ/F Flexi type unit FLXSB RXSJ/G Preliminary info For explanation on the benefits, see flap in the backcover of this catalogue. 70

73 Air flow Humidity control Air treatment Remote control & timer Other funtions

74 Ururu Sarara A UNIQUE COMBINATION OF HUMIDIFICATION, DEHUMIDIFICATION, VENTILATION AND AIR PURIFICATION Good temperature control is not all that is needed for a comfortable indoor climate. Precision control of humidity and ventilation of the room is essential. Thanks to the Ururu Sarara, you can humidify, dehumidify, ventilate and purify. The unit is fitted with filters that also filter dust, pollen and smoke. You can also adjust the air purification to meet your specific needs. Thanks to the ventilation system, contaminated indoor air in a space is replaced with fresh outdoor air. Good Design Award VENTILATION & HUMIDITY CONTROL HEATING & COOLING URURU HUMIDIFICATION: PLEASANT, EVEN DURING HEATING The Ururu humidification system absorbs moisture from the outdoor air and transports it to the indoor unit, quickly and efficiently humidifying the room. Thanks to the perfect combination of humidification and air conditioning, your room heats evenly. Temp.: 22 C Temp.: 22 C Humidity: 20% Cold feeling Ururu Humidity: 50% Comfortable feeling SARARA DEHUMIDIFICATION: FEEL THE DIFFERENCE! When humidity is too high, the Sarara dehumidication system ensures that it is lowered without changing the room temperature. That is ideal for you, because lower humidity means you feel more comfortable. Temp.: 25 C Temp.: 25 C Humidity: 80% Hot humid feeling Sarara Humidity: 50% Comfortable feeling The ideal humidity Comfortable air flow Powerful air purification Stylish design (good design award) Energy saving and high efficiency: one unit of energy is converted into more than five units of energy for cooling or heating 72

75 FTXRE / RXRE Wall mounted unit FTXR28,42,50E RXR28,42,50E ARC447A Energy efficient units: full range A class energy labels (5.00 EER; 5.14 COP) URURU humidification: maintains a comfortable humidity without any separate water supply SARARA dehumidification: maintains a comfortable and fresh indoor environment by removing moisture from the air without lowering the temperature Powerful ventilation refreshes the room within 2 hours Powerful air purification increases indoor air quality with Daikin Flash Streamer technology Good design award: unique evaluation criterion for industrial design in Japan Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Whisper quiet operation: down to 23dBA sound pressure Indoor unit silent operation: silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses 3D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces Other features: moisturizing operation mode, breeze cooling air flow, comfort sleep operation, mould shock operation Heating & Cooling Indoor units FTXR28E FTXR42E FTXR50E Cooling capacity Min./Nom./Max. kw 1.55/2.8/ /4.2/ /5.0/5.50 Heating capacity Min./Nom./Max. kw 1.30/3.6/ /5.1/ /6.0/6.20 Power input Cooling Min./Nom./Max. kw 0.250/0.560/ /1.050/ /1.46/1.8 Heating Min./Nom./Max. kw 0.220/0.700/ /1.180/ /1.51/1.77 EER COP SEER* Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour White Sound power Cooling Nom. dba Heating Nom. dba Sound pressure Cooling High/Nom./Low/ dba Silent operation Heating High/Nom./Low/ Silent operation dba 41/35/28/25 42/36/29/26 44/38/31/28 connections Gas OD mm Drain OD mm Outdoor units RXR28E RXR42E RXR50E Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20~18 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m *pren14825 (inquiry version 2010) 305x890x /33/26/23 42/35/27/24 44/37/29/ ~ / 50 / x795x ~ ~ / 50 /

76 FORM. FUNCTION. REDEFINED. TOTAL COMFORT ALL YEAR ROUND The Daikin Emura wall mounted air conditioning unit from Daikin is a remarkable blend of iconic design and engineering excellence. Its ultrathin profile and elegant finish in matt crystal white or brushed aluminium mean it will complement any interior. And those good looks certainly don t compromise its performance. Designed in Europe for European climates, you can rely on the Daikin Emura to deliver pleasant temperatures and consistent humidity s, whatever the season. It is designed to be mounted high on the wall, for optimum air distribution and whisperquiet operation. And it is as easy to operate as it is to install and maintain. Just as importantly, its A rating for energy efficiency will make it as attractive to the costconscious as the styleconscious. The Daikin Emura represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling. 74

77 FTXGJ / RXGK Wall mounted unit emura FTXG25,35,50J RXG25,35K ARC466A1 Energy efficient units: full range A class energy labels Energy saving during standby mode: reduction of energy from 10W to 2W Remarkable blend of iconic design and engineering excellence with an elegant finish in brushed aluminium or matt crystal white Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Indoor unit silent operation: silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Outdoor unit silent operation: silent button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room. Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air Heating & Cooling Indoor units Cooling capacity Min./Nom./Max. kw Heating capacity Min./Nom./Max. kw Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour Brushed aluminium Matt crystal white 295x915x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 45/40/35/32 45/40/35/32 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 45/40/35/32 45/40/35/32 connections Gas OD mm Drain OD mm Outdoor units Sound power Cooling Nom./High dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~18 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m * pren14825 (inquiry version 2010) *FTXG25JS *FTXG35JS *FTXG50JS *FTXG25JW *FTXG35JW *FTXG50JW 1.3/2.5/ /3.5/ /5.0/ /2.5/ /3.5/ /5.0/ /3.4/ /4.0/ /5.8/ /3.4/ /4.0/ /5.8/ ~ / 50 / ~ / 50 / ~ / 50 / ~ / 50 / *RXG25K *RXG35K *RXG50K *RXG25K *RXG35K *RXG50K 550x828x x901x x828x x901x /61 /63 /62 /61 /63 /62 46/43 48/44 46/43 48/44 47/44 48/45 47/44 48/45 10~ ~ / 50 / *Note: grey cells contain preliminary data

78 FTXLG / RXLG Wall Mounted Unit FTXL20,25,35G RXL20,25G ARC452A3 Optimised heating solution for your home Energy efficient: full range A class energy labels (COP = 4.58) High heating capacity: up to 6.6 kw Extended operation range for heating down to 20 C Weekly timer: allows to program the unit on a weekly basis 2 area intelligent eye: air flow is sent to the area in a room where no person is detected Energy saving during standby mode: reduction of energy from 10W to 2W ECONO mode decreases power consumption so that other appliances that need large power supply can be used Night set mode saves energy by preventing overcooling or overheating during night time Comfort mode guarantees draught free operation Powerful mode can be selected for rapid cooling or heating Whisper quiet operation: down to 23 dba sound pressure Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dBA Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses 3D air flow combines vertical and horizontal autoswing to circulate a stream of warm/cool air right to the corners of even large spaces Heating & Cooling Indoor units FTXL20G FTXL25G FTXL35G Cooling capacity Min./Nom./Max. kw 1.4/2.0/ /2.5/ /3.5/5.3 Heating capacity Min./Nom./Max. kw 1.4/2.7/ /3.4/ /4.0/6.6 Power input Cooling Min./Nom./Max. kw 0.35/0.45/ /0.55/ /0.87/1.81 Heating Min./Nom./Max. kw 0.34/0.59/ /0.77/ /0.92/2.01 EER COP Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour White Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low/ dba Silent operation Heating High/Nom./Low/ Silent operation dba 42/36/29/26 42/38/33/30 44/39/34/31 connections Gas OD mm Drain OD mm Outdoor units RXL20G RXL25G RXL35G 550x765x x825x300 Fan Air flow rate Cooling High/Low m³/min Heating High/Low m³/min Sound power Cooling Nom. dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20~20 connections length Max. OU IU m Level difference IU OU Max. m Heat insulation Total piping length System Actual m 295x800x /34/26/23 42/38/33/30 43/39/34/ ~ / 50 / / / / / / / /44 48/45 10~ Both liquid and gas pipes 1~ / 50 /

79 FTXSJ/G / RXSJ/F Wall mounted unit FTXS20,25,35,42,50J RXS20,25,35,42J ARC452A3 2 area intelligent eye: air flow is sent to the area in a room where no person is detected Energy saving during standby mode: reduction of energy from 10W to 2W Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Energy efficient units: up to A class energy labels ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Night set mode saves energy by preventing overcooling or overheating during night time Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Whisper quiet operation: down to 25dBA sound pressure Indoor / outdoor unit silent operation: Silent buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dBA Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses 3D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces Heating & Cooling Indoor units Cooling capacity Min./Nom./Max. kw Heating capacity Min./Nom./Max. kw Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh ,175 Energy label Cooling/Heating A/A B/B B/C Casing Colour White White 295x800x x1,050x250 Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low dba Heating High/Nom./Low dba 38/33/28 42/35/28 45/39/29 45/39/33 47/41/34 44/40/35/32 46/42/37/34 R410A connections Gas OD mm Drain OD mm Outdoor units Sound power Cooling Nom./High dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~20 15~20 R410A length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m *pren14825 (inquiry version 2010) *FTXS20J *FTXS25J *FTXS35J *FTXS42J *FTXS50J FTXS60G FTXS71G 1.3/2.0/ /2.5/ /3.5/ /4.2/ /5.0/ /6.0/ /7.1/ /2.7/ /3.3/ /4.0/ /5.4/ /5.8/ /7.0/ /8.2/ /32/25 41/33/25 45/37/29 45/39/33 46/40/34 45/41/36/33 46/42/37/ ~ / 50 / ~ / 50 / *RXS20J *RXS25J *RXS35J *RXS42J *RXS50J RXS60F RXS71F 550x828x x903x x825x x900x /61 /63 63/ 66/ 46/43 48/44 49/46 52/49 47/44 48/45 49/46 52/49 10~46 10~ ~ / 50 / ~ / 50 / *Note: grey cells contain preliminary data

80 FTXJV/GV / RXJV/GV Wall mounted unit FTX20,25,35JV RX20,25,35JV ARC433A87 Energy saving during standby mode: reduction of energy from 10W to 2W Energy efficient units: up to class A energy labels ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Night set mode saves energy by preventing overcooling or overheating during night time Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Whisper quiet operation: down to 22dBA sound pressure Indoor unit silent operation: silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room Heating & Cooling Indoor units FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GV Cooling capacity Min./Nom./Max. kw 1.3/2.0/ /2.5/ /3.3/ /5.0/ /6.0/ /7.1/8.5 Heating capacity Min./Nom./Max. kw 1.3/2.5/ /2.8/ /3.5/ /5.8/ /7.0/ /8.2/10.2 Power input Cooling Nom. kw /1.55/ /1.99/ /2.35/3.20 Heating Nom. kw /1.60/ /2.04/ /2.55/3.82 EER COP Annual energy consumption kwh ,175 Energy label Cooling/Heating A/A B/B B/C Casing Colour White Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low/ dba Silent operation Heating High/Nom./Low/ Silent operation dba 39/34/28/25 40/34/28/25 41/35/29/26 42/38/33/30 44/40/35/32 46/42/37/34 connections Gas OD mm Drain OD mm Outdoor units RX20JV RX25JV RX35JV RX50GV RX60GV RX71GV Fan Air flow rate Cooling High m³/min Heating High m³/min Sound power Cooling Nom. dba Sound pressure Cooling High dba Heating High dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~20 length Max. OU IU m connections Level difference IU OU Max. m IU IU Max. m Total piping length System Actual m 283x770x x1,050x /33/25/22 40/33/26/22 41/34/27/23 43/39/34/31 45/41/36/33 46/42/37/ ~ / 50 / x658x x825x x900x / / / / / / /44 49/46 52/ /45 49/46 52/49 10~ ~ / 50 /

81 FDXSE/C / RXSJ/G Slim concealed ceiling unit FDXS25,35E RXS25,35J ARC433A8 Energy efficient units: up to class A energy labels Compact dimensions, can easily be mounted in a ceiling void of only 240mm Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Medium external static pressure facilitates unit use with flexible ducts of varying lengths Home leave operation maintains the indoor temperature at your specified comfort during absence, thus saving energy Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Whisper quiet operation: down to 29dBA sound pressure Indoor unit silent operation: silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Outdoor unit silent operation: silent button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Standard air filter removes airborne dust particles to ensure a steady supply of clean air Heating & Cooling Indoor units *FDXS25E *FDXS35E *FDXS50C FDXS60C Cooling capacity Min./Nom./Max. kw 1.3/2.4/ /3.4/ /5.0/ /6.0/6.5 Heating capacity Min./Nom./Max. kw 1.3/3.2/ /4.0/ /5.8/ /7.0/8.0 Power input Cooling Nom. kw Heating Nom. kw EER COP ,030 3, Annual energy consumption kwh ,065 Energy label Cooling/Heating A/B B/C B/D C/D FanExternal static pressure Nom. Pa Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low/ dba Silent operation Heating High/Nom./Low/ Silent operation dba 35.0/33.0/31.0/ /35.0/33.0/ /36.0/34.0/32.0 R410A connections Gas OD mm Drain OD mm Outdoor units *RXS25J *RXS35J *RXS50J RXS60F Sound power Cooling Nom./High dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~20 15~18 R410A length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m 200x700x x900x x1,100x /33.0/31.0/ /35.0/33.0/ /36.0/34.0/ ~ / 50/60 / / ~ / 50/60 / / x828x x903x x825x /61 / /43 48/44 49/46 47/44 48/45 49/46 10~46 10~ ~ / 50 / ~ / 50 / *Note: grey cells contain preliminary data

82 Pure comfort Daikin introduces Nexura COMFORT IS KEY radiant heat Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling of wellbeing to your living space all year round. Its unobtrusive yet stylish design with a front panel that radiates additional heat, its low noise and reduced air flow turn your room into a haven. 80

83 FVXGK / RXGK Floor standing unit with radiant heat panel FVXG25,35,50K RXG25,35K Energy efficient units: full range A class energy labels The front panel of the indoor unit radiates additional heat to add to your comfort on cold days Whisper quiet operation: down to 19dBA sound pressure Comfortable vertical auto swing ensures draughtfree operation and prevents ceiling soiling Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Ideal for installation beneath a window ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Can be installed against a wall or recessed Heating & Cooling Indoor units Cooling capacity Min./Nom./Max. kw Heating capacity Min./Nom./Max. kw Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour White Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom/Low/Silent dba Heating High/Nom/Low/ dba Silent/Radiant 39/32/26/22/19 40/33/27/23/19 46/40/34/30/26 connections Gas OD mm Drain OD mm Outdoor units Sound power Cooling Nom./High dba Sound pressure *pren14825 (inquiry version 2010) Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~18 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m *FVXG25K *FVXG35K *FVXG50K 1.3/2.5/ /3.5/ /5.0/ /3.4/ /4.5/ /5.8/ x950x /32/26/23 39/33/27/24 44/40/36/ ~ / 50 / *RXG25K *RXG35K *RXG50K 550x828x x901x /61 /63 /62 46/43 48/44 47/44 48/45 10~ ~ / 50 / *Note: grey cells contain preliminary data

84 FVXSF / RXSJ Floor standing unit FVXS25,35,50F RXS25,35J ARC452A1 Energy efficient units: full range A class energy labels Outdoor unit silent operation: silent button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Ideal for installation beneath a window ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Whisper quiet operation: down to 23dBA sound pressure Indoor unit silent operation: silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room Can be installed against a wall or recessed Heating & Cooling Indoor units Cooling capacity Min./Nom./Max. kw Heating capacity Min./Nom./Max. kw Power input Cooling Min./Nom./Max. kw Heating Min./Nom./Max. kw EER COP SEER* Annual energy consumption kwh Energy label Cooling/Heating A/A Casing Colour White 600x700x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/26/23 38/32/26/23 39/33/27/24 39/33/27/24 44/40/36/32 45/40/36/32 connections Gas OD mm Drain OD mm Outdoor units Sound power Cooling Nom./High dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~20 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m * pren14825 (inquiry version 2010) *FVXS25F *FVXS35F *FVXS50F 1.3/2.5/ /3.5/ /5.0/ /3.4/ /4.5/ /5.8/ /0.57/ /1.02/ /1.55/ /0.79/ /1.22/ /1.60/ ~ / 50 / *RXS25J *RXS35J *RXS50J 550x828x x903x /61 /63 46/43 48/44 47/44 48/45 10~46 10~ ~ / 50 / *Note: grey cells contain preliminary data

85 FLXSB / RXSJ Flexi type unit FLXS25,35,50B RXS25,35J ARC433A6 Energy efficient units: up to class A energy labels Indoor/outdoor unit silent operation: Silent buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dBA Can fit on either ceiling or lower wall; its low height enables the unit to fit beneath a window Home leave operation maintains the indoor temperature at your specified comfort during absence, thus saving energy Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. Whisper quiet operation: down to 28dBA sound pressure Photocatalytic deodorising air purification filter deodorises the air, powerfully decomposes odours, removes house dust and pollen and helps to prevent bacterial and viral propagation to ensure a steady supply of clean air Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room Heating & Cooling Indoor units Cooling capacity Min./Nom./Max. kw Heating capacity Min./Nom./Max. kw Power input Cooling Min./Nom./Max. kw Heating Min./Nom./Max. kw EER COP Annual energy consumption kwh Energy label Cooling/Heating A/B B/C C/C Casing Colour Almond white 490x1,050x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 37/34/31/28 37/34/31/29 38/35/32/29 39/36/33/30 47/43/39/36 46/41/35/33 connections Gas OD mm Drain OD mm Outdoor units Sound power Cooling Nom./High dba Sound pressure Cooling High/Low dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~20 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m *FLXS25B *FLXS35B *FLXS50B 1.2/2.5/ /3.5/ /4.9/ /3.4/ /4.0/ /6.1/ /0.65/ /1.13/ /1.72/ /0.98/ /1.23/ /1.82/ ~ / 50/60 / / *RXS25J *RXS35J *RXS50J 550x828x x903x /61 /63 /63 46/43 48/44 48/44 47/44 48/45 48/45 10~ ~ / 50 / *Note: grey cells contain preliminary data

86

87 Multi model applications MXU & MXS INSTALLATION FLEXIBILITY A very wide range is available, from 2port to 5port units, making all applications possible. Up to 5 indoor units can be connected to 1 multi outdoor unit. All indoor units can be individually controlled with remote control and do not need to be installed in the same room or even at the same time. The outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall; WIDE CHOICE It is possible to combine different types of indoor units: wall mounted, floor standing, round flow cassette, ceiling suspended, flexi type, concealed ceiling, 4way blow cassette Outdoor multi split units are fitted with the Daikin swing compressor, renowned for its low noise and high energy efficiency. RXYSQ INSTALLATION FLEXIBILITY Up to 9 indoor units can be connected to 1 multi outdoor unit. All indoor units can be individually controlled with remote control and do not need to be installed in the same room or even at the same time. Narrow refrigerant piping makes handling and connecting easier, resulting in significantly reduced installation time. The Branch Provider (BP) unit varies the refrigerant volume to meet the cooling or heating requirements of a room. The BP is easy to disassemble, making repairing and recycling more simple. The REFNET joint reduces the amount of work involved in installation and increases the reliability of the system. A maximum total piping length of 145m offers much more flexibility in the choice of installation position for the indoor units and greatly simplifies system planning. WIDE CHOICE It is possible to combine different types of indoor units: wall mounted, floor standing, round flow cassette, ceiling suspended, flexi type, concealed ceiling. BP BP BP Refnet 5MXS90E RXYSQP8V1 85

88 MXUG Ururu Multi The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort cooling, heating, humidification and fresh air ventilation. Designed primarily for two room residential use, the system comprises a visually attractive wall mounted indoor unit and a robust outdoor unit that can be installed on a balcony or against a wall. For the humidification, called Ururu in Japanese, moisture is absorbed from the outdoor air. Subsequently, this humidified outdoor air streams into the indoor unit and is evenly distributed throughout the indoor areas. The Ururu Multi, therefore, works without a water reservoir and serves to evenly distribute humidified air. Humid heat operation however, is only available during the heat function. Unlike the conventional multi system, the Ururu Multi brings fresh, conditioned air into the room. Furthermore, the temperature of the incoming air is brought to the desired without cold or heat loss. Another benefit is that the air supply fan is accommodated in the outdoor unit, which means that you will never be bothered by any fan noises. Heating & Cooling CONNECTABLE INDOOR UNITS Indoor units CTXU25G CTXU35G CTXU42G CTXU50G Casing Colour White 295x800x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 42/38/33/30 42/38/33/30 43/39/34/31 44/39/34/31 connections Gas OD mm Drain / 50 / CONNECTABLE OUTDOOR UNITS Outdoor units Fan Air flow rate Cooling High/Nom./Low m³/min Heating High/Nom./Low m³/min Sound power Cooling Nom. dba Sound pressure Cooling High dba Heating High dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m 2MXU40G 2MXU50G 675x765x /33/30 37/34/34 32/32/32 34/34/ ~ Both liquid and gas pipes 30 1~ / 50 /

89 MXUG Combination tables Temp.: 22 C Temp.: 22 C Humidity: 20% Cold feeling Ururu Humidity: 50% Comfortable feeling 2MXU40,50G COOLING OUTDOOR UNIT 2MXU40G INDOOR UNIT HEATING OUTDOOR UNIT INDOOR UNIT COOLING OUTDOOR UNIT INDOOR UNIT HEATING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. COOLING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. EER COP EER COP ENERGY LABEL ENERGY LABEL ENERGY LABEL ENERGY LABEL AEC (kwh) AEC (kwh) 87

90 MXSE/F/G/H Multi model application Wide range from 2 to 5 port units Possibility to connect up to 5 indoor units All indoor units can be individually controlled and do not need to be installed in the same room or even at the same time Outdoor units are fitted with a Daikin swing compressor renowned for its low noise and high energy efficiency Possibility to combine different types of indoor units: wall mounted, floor standing, concealed ceiling, ceiling suspended units, round flow or 4way blow cassettes Heating & Cooling CONNECTABLE INDOOR UNITS Wall mounted Slim concealed ceiling Floor standing Flexi type Round flow cassette 4way blow cassette Concealed ceiling Ceiling suspended FTXGJ *FTXJV FTXSJ/G FDXSE/C FVXGK FVXSF FLXSB FCQC8 FFQBV FDBQB/FBQC FHQB *2MXS40H *2MXS50H 3MXS52E 3MXS68G 4MXS68F 1 4MXS80E 5MXS90E 2 1. Following combination is not possible: Following combination is not possible: , , CONNECTABLE INDOOR UNITS Indoor units FTXG25JW FTXG35JW *FTXG50JW Casing Colour White White 295x915x x915x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 45/40/35/32 45/40/35/32 R410A connections Gas OD mm Drain ~ / 50 / ~ / 50 / *Note: grey cells contain preliminary data 88

91 CONNECTABLE INDOOR UNITS Indoor units FTXG25JS FTXG35JS *FTXG50JS Casing Colour Silver Silver 295x915x x915x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 45/40/35/32 45/40/35/32 R410A connections Gas OD mm Drain ~ / 50 / ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units FTXS60G FTXS71G Casing Colour White 290x1,050x Sound power Cooling High/Nom. dba /61 /62 Heating High/Nom. dba /60 /62 Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 45/41/36/33 44/40/35/32 46/42/37/34 46/42/37/34 Refrigerant Type connections Gas OD mm Drain R410A ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units FTX20JV FTX25JV FTX35JV Casing Colour White 283x770x198 7 Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 39/33/25/22 39/34/28/25 40/33/26/22 40/34/28/25 41/34/27/23 41/35/29/26 Refrigerant Type R410A Drain connections 1~ / 50 / CONNECTABLE INDOOR UNITS Indoor units *FTXS20J *FTXS25J *FTXS35J *FTXS42J *FTXS50J Casing Colour White Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low dba Heating High/Nom./Low dba Refrigerant Type connections Gas OD mm Drain 295x800x /32/25 41/33/25 45/37/29 45/39/33 46/40/34 38/33/28 42/35/28 45/39/29 45/39/33 47/41/34 R410A ~ / 50 / *Note: grey cells contain preliminary data

92 CONNECTABLE INDOOR UNITS Indoor units *FVXG25K *FVXG35K *FVXG50K Casing Colour White 600x950x215 Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom/Low/ High/Nom/Low/ dba dba Silent/Radiant Silent 38/32/26/23 39/32/26/22/19 39/33/27/34 40/33/27/23/19 44/40/36/32 46/40/34/30/26 connections Gas OD mm Drain OD mm ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units FVXS25F FVXS35F FVXS50F Casing Colour White 600x700x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/26/23 38/32/26/23 39/33/27/24 39/33/27/24 44/40/36/32 45/40/36/32 connections Gas OD mm Drain ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units FLXS25B FLXS35B FLXS50B FLXS60B Casing Colour Almond white 490x1,050x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 37/34/31/28 37/34/31/29 38/35/32/29 39/36/33/30 47/43/39/36 46/41/35/33 48/45/41/39 47/42/37/34 connections Gas OD mm Drain ~ / 50 / 60 / / CONNECTABLE INDOOR UNITS Indoor units FDXS25E FDXS35E FDXS50C FDXS60C 200x700x x900x x1,100x FanExternal static pressure Nom. Pa Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 35.0/33.0/31.0/ /33.0/31.0/ /35.0/33.0/ /35.0/33.0/ /36.0/34.0/ /36.0/34.0/32.0 connections Gas OD mm Drain ~ / 50 / 60 / / *Note: grey cells contain preliminary data 90

93 CONNECTABLE INDOOR UNITS Indoor units Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 35.0/29.0 connections Gas OD mm Drain FDBQ25B 230x652x / / / ~ / 50 / 230 CONNECTABLE INDOOR UNITS Indoor units FBQ35C FBQ50C FBQ60C 300x700x x700x x1,000x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x800x500 55x1,100x500 Weight kg FanExternal static pressure High/Nom. Pa 100/30 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 37/29 connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /240 CONNECTABLE INDOOR UNITS Indoor units 17.5 Decoration panel Model BYFQ60BAW1 Colour White (RAL9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 29.5/ / / /32.0 connections Gas OD mm Drain FFQ25BV FFQ35BV FFQ50BV FFQ60BV 286x575x575 55x700x / / / / ~ / 50 / 230 CONNECTABLE INDOOR UNITS Indoor units Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm FCQ35C8 FCQ50C8 FCQ60C8 204x840x x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba Sound pressure Cooling High/Low dba 31/27 33/28 31/27 33/ connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50 / 60 / / Pure white standard panel with grey louvers; 2 Pure white standard panel with white louvers; 3 Pure white auto cleaning panel 91

94 CONNECTABLE INDOOR UNITS Indoor units FHQ35B FHQ50B FHQ60B Casing Colour White 195x960x x1,160x680 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 6.35 Gas OD mm Drain VP20 (I.D. 20/O.D. 26) 1~ / 50 / /48 54/49 55/49 53/48 54/49 55/49 37/32 38/33 39/33 37/32 38/33 39/33 CONNECTABLE OUTDOOR UNITS Outdoor units Fan Air flow rate Cooling High/Nom./Low m³/min Heating High/Low m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB Refrigerant Type connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Both liquid and gas pipes Both liquid and gas pipes Total piping length System Actual m *2MXS40H *2MXS50H 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E 550x765x x936x x900x /33/30 37/34/34 45// /49.4/ // /54.5/ /32/32 34/34/34 45/ /44.5/ / / ~46 10~46 15~24 15~15.5 R410A R410A ~ / 50 / ~ / 50 /

95 2MXSH Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max A A A 540 2MXS40H* A A A A A 525 Note: For connection to 2.0,2.5,3.5kW wall mounted D,E,G series HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max B C D A A A A A Note: For connection to 2.0,2.5,3.5kW wall mounted D,E,G series COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max A A A D E 1, A A A A A A A A A A A A A 720 Note: For connection to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max A B C D D A A A A A A A A A A A A A Note: For connection to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series EER COP EER COP ENERGY LABEL ENERGY LABEL ENERGY LABEL ENERGY LABEL AEC (kwh) AEC (kwh) 93 * This page contains preliminary data

96 3MXSE Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITy (kw) POWER INPUT COOLING (kw) A ROOM B ROOM C ROOM Min. Nom. Max. Min. Nom. max A A A A C A A A A A A A A A A A A A A A A A A A A A A A A 610 Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM Min. Nom. Max. Min. Nom. max A B D E E B B B B A B B B A B B A B A A A A A A A A A A A Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series EER ENERGY LABEL COP AEC (kwh) ENERGY LABEL 94 * This page contains preliminary data

97 3MXSG Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM C ROOM Min. Nom. Max. Min. Nom. Max. EER ENERGY LABEL AEC (kwh) A A A A C C 1, A A A C 1, C 1, B 1, A C 1, D 1, C 1, B 1, D 1, D 1, C 1, B 1, D 1, C 1, B 1, C 1, A 1, A A A 1, A 1, A 1, A A 1, A 1, A 1, A 1, A A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A A 1, A 1, A A 1, A 1,035 Note: For connection to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series; 6.0kW wall mounted F series 95 * This page contains preliminary data

98 3MXSE Combination tables HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM Min. Nom. Max. Min. Nom. Max A C D D E D B C D D D B C D D D B D D D B D D B D B A A A A A A A A A A A A A A A A A A A A A A A A A Note: For connection to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series; 6.0kW wall mounted F series COP ENERGY LABEL 96 * This page contains preliminary data

99 4MXSF Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max A A A A C C 1, A A A C 1, C 1, B 1, A C 1, D 1, C 1, B 1, D 1, D 1, C 1, B 1, D 1, C 1, B 1, C 1, A 1, A A A 1, A 1, A 1, A A 1, A 1, A 1, A 1, A A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A A 1, A 1,035 2,5+3,5+5, A 990 2,5+4,2+4, A 1,035 3,5+3,5+3, A 1, A A A A A A A A A A A A A 850 Note: For connection to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series; 6.0kW wall mounted F series EER ENERGY LABEL AEC (kwh) 97 * This page contains preliminary data

100 4MXSF Combination tables HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max A C D D E D B C D D D B C D D D B D D D B D D B D B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: For connection to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series; 6.0kW wall mounted F series COP ENERGY LABEL 98 * This page contains preliminary data

101 4MXSE Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. EER ENERGY LABEL AEC (kwh) A A C D D B D 1, A A B C 1, D 1, C 1, C 1, A B D 1, D 1, C 1, C 1, D 1, E 1, D 1, D 1, D 1, E 1, E 1, D 1, D 1, D 1, D 1, C 1, B 1, B 1, B 1, A A 1, C 1, C 1, C 1, B 1, B 1, B 1, C 1, C 1, C 1, B 1, B 1, C 1, C 1, C 1, B 1, B 1, C 1, C 1, B 1, B 1, C 1, A 1, A 1, A 1, C 1, C 1, C 1, C 1, B 1, B 1, D 1, D 1, C 1, B 1, B 1, D 1,435 Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type / op 6.0 en 7.1 wall mounted F type 99 * This page contains preliminary data

102 4MXSE Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. EER ENERGY LABEL AEC (kwh) C 1, B 1, B 1, C 1, A 1, A 1, D 1, D 1, C 1, B 1, B 1, D 1, C 1, B 1, C 1, A 1, D 1, C 1, B 1, C 1, A 1, A 1, A 1, A 1, B 1, A 1, A 1, A 1, B 1, B 1, B 1, A 1, A 1, B 1, B 1, B 1, A 1, B 1, B 1, A 1, A 1, A 1, B 1, B 1, B 1, A 1, A 1, B 1, B 1, B 1, A 1, B 1, B 1, A 1, B 1, B 1, B 1, B 1, B 1, B 1, B 1, B 1, A 1, B 1, B 1, B 1, A 1, B 1, B 1, B 1, B 1, B 1, B 1, B 1,290 Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type / op 6.0 en 7.1 wall mounted F type 100 * This page contains preliminary data

103 4MXSE Combination tables HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL HEATING CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max A B D D B C D A A A B A A A B B C B A A D D B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series / op 6.0 en 7.1kW wall mounted F series COP ENERGY LABEL 101 * This page contains preliminary data

104 4MXSE Combination tables HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL HEATING CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series / op 6.0 en 7.1kW wall mounted F series COP ENERGY LABEL 102 * This page contains preliminary data

105 5MXSE Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max A A B B B B D 1, A A A B C 1, B 1, C 1, A B C 1, D 1, C 1, C 1, D 1, D 1, D 1, C 1, D 1, D 1, D 1, D 1, D 1, D 1, D 1, D 1, C 1, C 1, C 1, A A B 1, B 1, C 1, B 1, B 1, A 1, B 1, C 1, C 1, B 1, C 1, C 1, C 1, C 1, C 1, C 1, D 1, D 1, C 1, C 1, D 1, B 1, B 1, A 1, A 1, B 1, C 1, C 1, C 1, B 1, C 1, C 1, D 1, C 1, C 1, C 1, D 1, D 1,610 Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series / op 6.0 en 7.1kW wall mounted F series EER ENERGY LABEL AEC (kwh) 103 * This page contains preliminary data

106 5MXSE Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max C 1, C 1, D 1, C 1, B 1, A 1, A 1, D 1, D 1, D 1, C 1, C 1, D 1, D 1, C 1, C 1, D 1, C 1, B 1, A 1, D 1, D 1, C 1, C 1, D 1, C 1, C 1, A 1, A 1, A 1, B 1, B 1, A 1, B 1, A 1, B 1, B 1, B 1, A 1, B 1, B 1, C 1, C 1, A 1, A 1, C 1, C 1, A 1, A 1, B 1, A 1, A 1, B 1, B 1, B 1, A 1, A 1, B 1, C 1, C 1, A 1, A 1, C 1, C 1, A 1, B 1, A 1, C 1, C 1, C 1, A 1, C 1, C 1, B 1, C 1,580 Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series / op 6.0 en 7.1kW wall mounted F series EER ENERGY LABEL AEC (kwh) 104 * This page contains preliminary data

107 5MXSE Combination tables COOLING OUTDOOR UNIT INDOOR UNIT COOLING CAPACITY (kw) TOTAL CAPACITY POWER INPUT (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max C 1, B 1, B 1, C 1, C 1, A 1, A 1, C 1, C 1, C 1, A 1, A 1, C 1, C 1, A 1, B 1, C 1, C 1, C 1, A 1, C 1, C 1, C 1, C 1, C 1, C 1, C 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, B 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, B 1, B 1, A 1, A 1, B 1, A 1, A 1, A 1, B 1, A 1, A 1, B 1, B 1, A 1, A 1, B 1, A 1, A 1, A 1, B 1, A 1, A 1, B 1, A 1, B 1, A 1, A 1,375 Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series / op 6.0 en 7.1kW wall mounted F series EER ENERGY LABEL AEC (kwh) 105 * This page contains preliminary data

108 5MXSE Combination tables HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max B C D D D D D A A C C B B C B D D B C C D D C C C E D C C D C B A A A A A A B B A A A A B B A A B C C A A C C A A B A A A A A B C C A A C C C A A C C Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0kW wall mounted G series / op 6.0 en 7.1kW wall mounted F series COP ENERGY LABEL 106 * This page contains preliminary data

109 5MXSE Combination tables HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max A A B A A A A C C C A A C B A A B A A A C B A A B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to kW COP ENERGY LABEL 107 * This page contains preliminary data

110 5MXSE HEATING OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to kW COP ENERGY LABEL 108 * This page contains preliminary data

111 RXYSQP8V1 VRV IIIS heat pump for residential application Possibility to connect up to 9 indoor units All indoor units can be individually controlled and do not need to be installed in the same room or even at the same time Possibility to combine different types of indoor units: wall mounted, floor standing, concealed ceiling, ceiling suspended units, round flow or 4way blow cassettes Heating & Cooling CONNECTABLE INDOOR UNITS Wall mounted Floor standing Concealed ceiling Flexi type Round flow cassette 4way blow cassette Ceiling suspended FTXGJW/S FTXSJ/G FVXGK FVXSF FDBQB FDXSE FDXSC FBQC FLXSB FCQC8 FFQBV FHQB RXYSQP8V1 CONNECTABLE INDOOR UNITS Indoor units FTXG25JS FTXG35JS *FTXG50JS Casing Colour Silver Silver 295x915x x915x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 45/40/35/32 45/40/35/32 R410A connections Gas OD mm Drain ~ / 50 / / 50 / *Note: grey cells contain preliminary data 109

112 CONNECTABLE INDOOR UNITS Indoor units FTXG25JW FTXG35JW *FTXG50JW Casing Colour White White 295x915x x915x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/25/22 39/34/28/25 42/34/26/23 42/36/29/26 45/40/35/32 45/40/35/32 R410A connections Gas OD mm Drain ~ / 50 / / 50 / CONNECTABLE INDOOR UNITS Indoor units *FTXS20J *FTXS25J *FTXS35J *FTXS42J *FTXS50J Casing Colour White 295x800x Sound power Cooling High dba Heating High dba Sound pressure Cooling High/Nom./Low dba 38/32/25 41/33/25 45/37/29 45/39/33 46/40/34 Heating High/Nom./Low dba 38/33/28 42/35/28 45/39/29 45/39/33 47/41/34 connections Gas OD mm Drain ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units FTXS60G FTXS71G Casing Colour White 290x1,050x Sound power Cooling High/Nom. dba /61 /62 Heating High/Nom. dba /60 /62 Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 45/41/36/33 44/40/35/32 46/42/37/34 46/42/37/34 connections Gas OD mm Drain Power supply Phase / Frequency / Voltage Hz/V ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units Annual energy consumption kwh *FVXG25K 1,250 *FVXG35K 1,750 *FVXG50K 2,500 Energy label Cooling/Heating A/A Casing Colour White 600x950x215 Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom/Low/ High/Nom/Low/ dba dba Silent/Radiant Silent 38/32/26/23 39/32/26/22/19 39/33/27/34 40/33/27/23/19 44/40/36/32 46/40/34/30/26 connections Gas OD mm Drain OD mm ~ / 50 / *Note: grey cells contain preliminary data

113 CONNECTABLE INDOOR UNITS Indoor units FVXS25F FVXS35F FVXS50F Casing Colour White 600x700x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 38/32/26/23 38/32/26/23 39/33/27/24 39/33/27/24 44/40/36/32 45/40/36/32 connections Gas OD mm Drain ~ / 50 / CONNECTABLE INDOOR UNITS Indoor units FLXS25B FLXS35B FLXS50B FLXS60B Casing Colour Almond white 490x1,050x Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 37/34/31/28 37/34/31/29 38/35/32/29 39/36/33/30 47/43/39/36 46/41/35/33 48/45/41/39 47/42/37/34 connections Gas OD mm Drain ~ / 50 / 60 / / CONNECTABLE INDOOR UNITS Indoor units FDXS25E FDXS35E FDXS50C FDXS60C 200x700x x900x x1,100x FanExternal static pressure Nom. Pa Sound power Cooling High dba Heating High dba Sound pressure Heating Cooling High/Nom./Low/ High/Nom./Low/ dba dba Silent operation Silent operation 35.0/33.0/31.0/ /33.0/31.0/ /35.0/33.0/ /35.0/33.0/ /36.0/34.0/ /36.0/34.0/32.0 connections Gas OD mm Drain ~ / 50 / 60 / / CONNECTABLE INDOOR UNITS Indoor units Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 35.0/29.0 connections Gas OD mm Drain FDBQ25B 230x652x / / / ~ / 50 /

114 CONNECTABLE INDOOR UNITS Indoor units FBQ35C FBQ50C FBQ60C 300x700x x1,000x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x800x500 55x1,100x500 Weight kg FanExternal static pressure High/Nom. Pa 100/30 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 37/29 connections 6.35 Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /240 CONNECTABLE INDOOR UNITS Indoor units 17.5 Decoration panel Model BYFQ60BAW1 Colour White (RAL9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 29.5/ / / /32.0 connections Gas OD mm Drain FFQ25BV FFQ35BV FFQ50BV FFQ60BV 286x575x575 55x700x / / / / ~ / 50 / 230 CONNECTABLE INDOOR UNITS Indoor units Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba FCQ35C8 FCQ50C8 FCQ60C8 204x840x x950x950 / 50x950x950 / 130x950x / 5.5 / /27 33/28 31/27 33/ connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50 / 60 / / Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel CONNECTABLE INDOOR UNITS Indoor units FHQ35B FHQ50B FHQ60B Casing Colour White 195x960x x1,160x680 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 6.35 Gas OD mm Drain VP20 (I.D. 20/O.D. 26) 1~ / 50 / /48 54/49 55/49 53/48 54/49 55/49 37/32 38/33 39/33 37/32 38/33 39/33 112

115 Outdoor units *RXYSQ4P8V1 *RXYSQ5P8V1 *RXYSQ6P8V1 Capacity range HP Cooling capacity Nom. kw Heating capacity Nom. kw Power input 50Hz Cooling Nom. kw Heating Nom. kw EER COP Maximum number of connectable indoor units Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Operation range Heating Min.~Max. CWB 20~15.5 Liquid (OD)/Gas/Drain mm 9.52 / 19.1 / 26x3 connections length (max) mm length For 1 room m 15 (BP to IU) (max) Total m 55 (OU to BP) / 60 (BP to IU) 55 (OU to BP) / 80 (BP to IU) 55 (OU to BP) / 90 (BP to IU) Max. internunit difference m 15 Inst. height diff. Maximum 30 1N~ / 50 / Branch provider BPMKS967B2 BPMKS967B3 Connectable indoor units Max. indoor unit connectable capacity Max. connectable combination Dimensions Height x Width x Depth mm Weight kg 1~2 1~ x294x *Note: grey cells contain preliminary data 113

116

117 LIGHT COMMERCIAL APPLICATIONS NEW NEW NEW NEW Benefits overview 116 Outdoor units overview 118 PAIR APPLICATIONS Cassette Units FCQGE / RZQGL 120 Auto cleaning panel 122 FCQHD8 / RZQD3V1/D9V1 123 FCQHD8 / RZQB9W1 124 FCQHD8 / RZQSDV1 125 FCQC8 / RZQD3V1/D9V1 126 FCQC8 / RZQB9W1 127 FCQC8 / RZQSDV1 128 FCQC8 / RXSJ/F 129 FFQBV / RXSJ/F 130 Concealed Ceiling Units 133 FBQC: inverter driven fan 133 FBQC / RZQD3V1/D9V1 131 FBQC / RZQB9W1 132 FBQC / RZQSDV1 133 FBQC / RXSJ/F 134 FDQB / RZQD9V1 135 FDQB / RZQB9W1 136 FDQB / RZQSDV1 137 FDQB / RZQC 138 NEW NEW NEW Wall Mounted Units 139 FAQB / RZQD3V1/D9V1 139 FAQB / RZQB9W1 140 FAQB / RZQSDV1 141 Ceiling Suspended Units 142 FHQGC / RZQGL 142 FHQGC / RZQD3V1/D9V1 143 FHQB / RZQD3V1/D9V1 144 FHQB / RZQB9W1 145 FHQB / RZQSDV1 146 FHQB / RXSJ/F 147 FUQB / RZQD3V1/D9V1 148 FUQB / RZQB9W1 149 Floor Standing Unit 150 FVQB / RZQSDV1 150 COMMERCIAL MULTI SYSTEM 152 CMSQA 152 TWIN, TRIPLE, DOUBLE TWIN APPLICATIONS 154 RZQD3V1/D9V1/B9W1 154 RZQCY1 157 RZQSDV1 160 ROOFTOP 164 UATYQBY1 164 UATYPAY1 165 For more information on Options & Control Systems, please refer to page 276 of this catalogue.

118 Benefits overview We care icons Comfort Air treatment FCQGE FCQHD8 Ceiling mounted cassette FCQC8 FMCQA8 FFQBV FBQC Concealed ceiling unit FMDQB FDQB Ceiling suspended unit FHQGC FHQB 4Way blow ceiling suspended unit FUQB Wall mounted unit FAQB Floor standing unit FVQB For explanation on the benefits, see flap in the backcover of this catalogue. 116

119 Humidity control Air flow Remote control & timer Other funtions (50 class) 8 (60~125 class) 3 (125, 200 class) 2 (250 class)

120 RZQGL/RZQD Seasonal efficiency DAIKIN S SEASONAL EFFICIENCY OUTDOOR UNITS ALREADY INTEGRATES ECODESIGN PRINCIPLE While EcoDesign Directive is scheduled to come into force no earlier than 2013, Daikin is already integrating the EcoDesign principle in its light commercial range, by launching the first Sky Air range in the market optimized for seasonal efficiency: the Seasonal Inverter. Daikin continues to improve and already integrates the 2015 EcoDesign requirements by introducing the new RZQGL series, ensuring an increase in seasonal efficiency even compared to the Seasonal Inverter. Optimized inverter control over the full temperature distribution curve provides optimum partial load performance, giving it high ratings in reallife operation conditions. Auxiliary modes have also been redesigned. Thanks to this new design, the Sky Air Seasonal Inverter boasts up to 20% better seasonal efficiency than the current Sky Air Super Inverter in reallife situations and more than 50% compared to noninverter systems, thus contributing to the EU Commission s targets. Next to its high seasonal performance, the outdoor units optimized for seasonal efficiency offers an important number of features, such as a wide operation range, reuse technology and a night quiet mode function. REUSE TECHNOLOGY Previously, R22 pipe work could only be used by using cleaning filters to remove the residue from the R22 pipe work. However Daikin continues to provide a complete filterless solution for the replacement of R22 systems and reuse existing pipe work. For Sky Air this was already available on the Super Inverter range RZQDV1 & RZQBW1 and Seasonal Inverter RZQD3/D9V1 & RZQB9W1 and is also available on the new RZQGL series. REUSE R22 EXISTING PIPE WORK FOR SKY AIR Filterless technology which is used by Daikin can be used on all R22 systems, which are still running at the time of replacing and have no history of compressor burnout. When the synthetic oil of an R410A system becomes contaminated with the mineral oil of an R22 system (>1%), it will cause some damage on e.g. the expansion valves. With the Daikin Reuse technology, each system will be required to run for 30 minutes in cooling before pump down to make sure the mineral oil is removed as much as possible from the system. For more detailed information, please contact your local dealer. The full range of Sky Air indoor units (like Round flow Cassette, concealed ceiling unit, wall mounted unit ) can be used in combination with the inverter RZQD3V1/D9V1, RZQBW1 models, the capacity range is from 7kW to 14kW. Also the new round flow cassette (FCQG) and ceiling suspended cassette (FHQG) can be used in combination with the new inverter RZQG71,100,125,140L models. SYSTEM LAYOUT Replacement technology is as well possible for twin, triple and double twin, under certain conditions. R22 outdoor unit R22 refrigerant piping R410A RZQ outdoor unit R22 refrigerant piping R22 indoor R410A indoor 118

121 RZQSD Comfort Inverter Sky Air Comfort Inverter units provide inverter solutions for customers requiring the comfort of inverter technology but without the need for the top class performance of the Sky Air Seasonal Inverter and RZQGL series. The integrated inverter technology ensures energy savings and very high comfort s. Capacity classes ranging from 71 up to 140 class Ensures maximum comfort Sound pressure performance down to 47dBA Wide operation range Wide range of possible indoor units: 8 different models in 33 different variants Comparison Seasonal Inverter, RZQGL series and Comfort Inverter OUTDOOR UNITS RZQGL RZQD RZQSDV1 Wide product range 7.1~14kW (single phase) 7.1~14kW (single and three phase) 7.1~14kW (single phase) Wide operation range Up to 20 C in heating mode Up to 20 C in heating mode Up to 15 C in heating mode Night quiet mode Standard feature Standard feature Standard feature Remote control 24 hour and weekly schedule timer 24 hour and weekly schedule timer 24 hour and weekly schedule timer Maximum piping length 75m 75m 50m Minimum piping length No limitation 5m 5m Maximum installation height difference 30m 30m 30m Extra Optimized for seasonal efficiency Optimized for seasonal efficiency Suits computer room applications Suits computer room applications Reuse of existing R22 or R407C piping Reuse of existing R22 or R407C piping *Note: grey cells contain preliminary data CMSQA Commercial Multi System CMSQ is especially developed for light commercial multi applications (highend market) 2025 kw, offering top COP/EER and individual control. Main sales features: Multi applications High efficiency: EER up to 3.71 and COP up to indoor types: unique Round flow cassettes and concealed ceiling units with inverter driven fan Individual control: up to 4 indoors can be individually controlled (on a CMSQ system) Asymmetric combination is allowed Easy and flexible installation Maximum piping length up to 200m and height difference up to 30m (outdoor unit indoor unit) Indoor installation is possible (an ESP of 50 Pa is available on the outdoor unit) Integration to Intelligent Touch Controller and Intelligent Manager Comparison Commercial Multi System and Super Inverter OUTDOOR UNITS RZQC Wide operation range Up to 20 C in heating mode Up to 15 C in heating mode Control indoor Individual control No individual control Indoor connection Asymmetric combination No asymmetric combination Maximum number of indoor units 4 Double twin Maximum piping length Maximum difference Height difference between indoors Height difference between indoor and first bench 15 CMSQA 119

122 FCQGE / RZQGL Round flow cassette OPTIMIZED FOR SEASONAL EFFICIENCY FCQG71,100,125,140E RZQG71L BRC1E51A Improved Seasonal efficiency SEER: up to 4.67! (PrEN14825 inquiry version 2010) Energy efficient units: full range A class energy labels Seasonal efficiency, optimized for all seasons. 360 air discharge ensures uniform air flow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room 23 different air flow patterns possible Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season. The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable environment and offers great savings in energy consumption to shop, restaurant and office owners Heating & Cooling Indoor units * FCQG71E * FCQG100E * FCQG125E * FCQG140E Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.0/ /14.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /16/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh , ,665 2,180 Energy label Cooling/Heating A/A A/ A/A Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba connections Liquid mm 9.52 Gas mm 15.9 Drain mm VP25 (OD 32) 1~ / 50 / Outdoor units * RZQG71L * RZQG100L * RZQG125L * RZQG140L 990x940x320 1,430x940x320 Fan Air flow rate Cooling m³/min Heating Sound power Cooling Heating Sound pressure m³/min dba dba Cooling Nom. dba Heating Nom. dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20~15.5 connections Gas OD mm Drain OD mm length Max. OU IU m Level difference IU OU Max. m Total piping length System Actual m * pren14825 (inquiry version 2010) 288x840x ~ ~ / 50 /

123 FHQGC / RZQGL

124 BYCQ140CG Auto cleaning decoration panel, option for round flow cassette DAIKIN INTRODUCES FIRST AUTO CLEANING CASSETTE TO EUROPEAN MARKET Daikin launches a decoration panel for the round flow cassette, equipped with a special filter, which automatically cleans itself once a day. All dust coming from this filter is stored in the indoor unit and can be removed with a normal vacuum cleaner. With this decoration panel energy and maintenance costs will be lower and comfort will be increased HIGHER EFFICIENCY AND COMFORT FROM DAILY AUTO CLEANING OF THE FILTER Energy savings up to 10% With a standard decoration panel the energy consumption of the unit increases slowly because dust accumulates in the filter. After the filter is cleaned the energy consumption is back at the of installation. With the auto cleaning decoration panel the filter is cleaned everyday and therefore the energy consumption remains constant, resulting in an energy saving up to 10% compared to yearly filter cleaning. Accumulation of dirt in the filter causes energy consumption to increase Electricity consumption ratio (%) EASY REMOVAL OF DUST WITH A VACUUM CLEANER WITHOUT OPENING THE UNIT Dust is stored in dust box Emptying the dust box can be done with a vacuum cleaner No rearrangement of shop interior etc to access the unit Only a vacuum cleaner is required, no ladder or other equipment Qualified personnel is not necessary No manual cleaning not required to touch the dust 100 Day 1: equal energy consumption After 1 year: > 20% increase in energy consumption => An average increase of 10% in energy consumption on a yearly basis Operation years Filter is never cleaned Filter is cleaned once a year Filter is cleaned every day LOWER MAINTENANCE COSTS THANKS TO AUTO CLEANING FUNCTION Less time needed for filter maintenance Less qualified personnel required 122

125 FCQHD8 / RZQD3V1/D9V1 Round flow cassette FCQH100,125,140D8 RZQ100,125,140D9V1 BRC1E51A BRC7F532F High COP round flow cassette: full range A class 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel in white (RAL9010) with grey louvers For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units FCQH71D8 FCQH100D8 FCQH125D8 FCQH140D8 Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ /14.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ /16.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 940 1,250 1,740 2,180 Energy label Cooling/Heating A/A 246x840x x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 36/28 45/32 45/36 45/38 connections Gas OD mm Drain OD mm Outdoor units RZQ71D3V1 RZQ100D9V1 RZQ125D9V1 RZQ140D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Both liquid and gas pipes 1~ / 50 / Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 50x950x950 / 50x950x950 / 130x950x / 5.5 / /28 45/32 45/36 45/ ~ / 50/60 / / ~50.0

126 FCQHD8/ RZQB9W1 Round flow cassette FCQH100,125,140D8 RZQ100,125,140B9W1 BRC1E51A BRC7F532F High COP round flow cassette: up to class A energy labels 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units FCQH100D8 FCQH125D8 FCQH140D8 Cooling capacity Min./Nom./Max. kw /10.00 / /12.50 / /14.00 / Heating capacity Min./Nom./Max. kw /11.20 / /14.00 / /16.00 / Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 1,220 1,770 2,325 Energy label Cooling/Heating A/A B/B 288x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White (RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 45/32 45/36 45/38 connections Gas OD mm Drain OD mm Outdoor units RZQ100B9W1 RZQ125B9W1 RZQ140B9W1 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation 2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 50x950x950 / 50x950x950 / 130x950x / 5.5 / /32 45/36 45/ ~ / 50/60 / /220 1,345x900x ~ Both liquid and gas pipes 3N~ / 50 / 400

127 FCQHD8 / RZQSDV1 Round flow cassette FCQH100,125,140D8 RZQS100,125,140DV1 BRC1E51A BRC7F532F High COP round flow cassette: up to class A energy labels 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units FCQH71D8 FCQH100D8 FCQH125D8 FCQH140D8 Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ /14.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ /16.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP Annual energy consumption kwh 1,076 1,449 1,941 2,326 Energy label Cooling/Heating A/A B/B 246x840x x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White (RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 36/28 45/32 45/36 45/38 connections Gas OD mm Drain OD mm Outdoor units RZQS71DV1 RZQS100DV1 RZQS125DV1 RZQS140DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba 50x950x950 / 50x950x950 / 130x950x / 5.5 / /28 45/32 45/36 45/38 Operation range Cooling Ambient Min.~Max CDB Heating Ambient Min.~Max CWB 15~15.5 length Max. OU IU m connections Level difference IU OU Max. m IU IU Max. m 0.5 Heat insulation Both liquid and gas pipes Total piping length System Actual m 1~ / 50 / Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel ~ / 50/60 / / ~46

128 FCQC8 / RZQD3V1/D9V1 Round flow cassette FCQ100,125,140C8 RZQ100,125,140D9V1 BRC1E51A BRC7F532F 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units FCQ71C8 FCQ100C8 FCQ125C8 FCQ140C8 Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ /14.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ /16.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 1,055 1,319 1,849 2,555 Energy label Cooling/Heating A/A D/C 204x840x x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 34/28 37/32 41/35 42/35 connections Gas OD mm Drain OD mm Outdoor units RZQ71D3V1 RZQ100D9V1 RZQ125D9V1 RZQ140D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Both liquid and gas pipes 1~ / 50 / Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 50x950x950 / 50x950x950 / 130x950x / 5.5 / /28 37/32 41/ ~ / 50/60 / / ~50.0

129 FCQC8 / RZQB9W1 Round flow cassette FCQ100,125,140C8 RZQ100,125,140B9W1 BRC1E51A BRC7F532F 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units FCQ100C8 FCQ125C8 FCQ140C8 Cooling capacity Min./Nom./Max. kw /10.00/ /12.50/ /14.00/ Heating capacity Min./Nom./Max. kw /11.20/ /14.00/ /16.00/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 1,320 1,940 2,680 Energy label Cooling/Heating A/B A/C D/D 246x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/32 41/35 42/35 connections Gas OD mm Drain OD mm Outdoor units RZQ100B9W1 RZQ125B9W1 RZQ140B9W1 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation 2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 50x950x950 / 50x950x950 / 130x950x / 5.5 / /32 41/ ~ / 50/60 / /220 1,345x900x ~ Both liquid and gas pipes 3N~ / 50 / 400

130 FCQC8 / RZQSDV1 Round flow cassette FCQ100,125,140C8 RZQS100,125,140DV1 BRC1E51A BRC7F532F 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units FCQ71C8 FCQ100C8 FCQ125C8 FCQ140C8 Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER / COP Cooling / Heating 3.11 / / / 3.21 Annual energy consumption kwh 1,141 1,608 2,010 2,682 Energy Label Cooling / Heating B / B D / C 204x840x x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba Sound pressure Cooling High/Low dba 33/28 37/32 41/35 34/28 37/32 41/35 42/ connections Gas OD mm 15.9 Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 Outdoor units RZQS71DV1 RZQS100DV1 RZQS125DV1 RZQS140DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet Level 1 dba mode Operation range Cooling Ambient Min.~Max. CDB 5.0~46 Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m 2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel Both liquid and gas pipes 1~ / 50 /

131 FCQC8 / RXSJ/F Round flow cassette FCQ3560C8 RXS60F BRC1E51A BRC7F532F Energy efficient units: up to class A energy labels 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 3 different variations: Standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel For auto cleaning panel:» Daikin introduces first auto cleaning cassette to European market 1» Higher efficiency and comfort from daily auto cleaning of the filter 1» Lower maintenance costs thanks to auto cleaning function 1» Easy removal of dust with a vacuum cleaner without opening the unit 1 Fresh air intake: up to 20 % (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Drainup pump with 850mm lift fitted as standard 1 Only for auto cleaning panel BYCQ140CG Heating & Cooling Indoor units *FCQ35C8 *FCQ50C8 FCQ60C8 Cooling capacity Min./Nom./Max. kw 1.4/3.4/ /5.0/ /5.7/6.0 Heating capacity Min./Nom./Max. kw 1.4/4.2/ /6.0/ /7.0/8.0 Power input Cooling Nom. kw Heating Nom. kw EER COP Annual energy consumption kwh Energy label Cooling/Heating A/B A/A A/B 204x840x x840x Decoration panel Model BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 BYCQ140CW1 2 / BYCQ140CW1W 3 / BYCQ140CGW1 4 Colour Pure White(RAL 9010) Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / / 5.5 / 11.5 Sound power Cooling High dba Sound pressure Cooling High/Low dba 31/27 33/28 31/27 33/28 R410A connections Gas OD mm Drain OD mm Outdoor units *RXS35J *RXS50J RXS60F 550x828x x903x x825x Sound power Cooling Nom./High dba /63 63 Sound pressure Cooling High/Low dba 48/44 49/46 48/45 49/46 Operation range Cooling Ambient Min.~Max CDB 10~46 10~46 Heating Ambient Min.~Max CWB 15~20 15~20 R410A connections length Max. OU IU m Level difference IU OU Max. m Total piping length System Actual m ~ / 50/60 / /220 1~ / 50/60 / / ~ / 50 / ~ / 50 / Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel *Note: grey cells contain preliminary data 129

132 FFQBV / RXSJ/F 4way blow ceiling mounted cassette FFQ60BV RXS60F BRC1E51A BRC7E530W Compact casing (575mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Whisper quiet operation: down to 24.5dBA sound pressure Fresh air intake for healthy living Comfortable horizontal auto swing ensures draughtfree operation and prevents ceiling soiling Since the flaps can move to a 0 degree position, virtually no draught can be experienced Possibility to shut 1 or 2 flaps for easy installation in corners 2way blow 3way blow 4way blow Easy maintenance: switch box can be reached by simply removing the suction grille Standard drain pump with 750mm lift Heating & Cooling Indoor units *FFQ25BV *FFQ35BV *FFQ50BV FFQ60BV Cooling capacity Min./Nom./Max. kw 1.3/2.5/ /3.4/ /4.7/5.6 /5.80/ Heating capacity Min./Nom./Max. kw 1.3/3.2/ /4.5/ /5.5/7.0 /7.00/ Power input Cooling Min./Nom./Max. kw 0.30/0.83/ /1.30/ /1.80/2.26 /2.07/ Heating Min./Nom./Max. kw 0.29/0.935/ /1.60/ /1.96/2.78 /2.49/ EER COP Annual energy consumption kwh ,035 Energy label Cooling/Heating A/B B/C D/D D/D 286x575x x575x Decoration panel Model BYFQ60BAW1 BYFQ60BAW1 Colour White (RAL9010) White (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 55x700x700 Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 29.5/ / / / / / / /32.0 R410A connections Gas OD mm Drain OD mm ~ / 50 / 230 1~ / 50 / 230 Outdoor units *RXS25J *RXS35J *RXS50J RXS60F 550x828x x903x x825x Fan Air flow rate Cooling High/Low m³/min 50.9/45.0 Heating High/Low m³/min 46.3/46.3 Sound power Cooling Nom. dba Sound pressure Cooling High/Low dba 46/43 48/44 49/46 47/44 48/45 49/46 Operation range Cooling Ambient Min.~Max. CDB 10~46 10~46 Heating Ambient Min.~Max. CWB 15~20 15~18 R410A length Max. OU IU m connections Level difference IU OU Max. m Heat insulation Both liquid and gas pipes Total piping length System Actual m 1~ / 50 / ~ / 50 / *Note: grey cells contain preliminary data

133 FBQC / RZQD3V1/D9V1 Concealed ceiling unit with inverter driven fan FBQ71C RZQ71D3V1 BRC1E51A Energy efficient units: up to class A energy labels Reduction in power consumption thanks to DC inverter fans Improved comfort thanks to 3step airflow control Maximum external static pressure (ESP) is 120Pa Possibility to change ESP through wired remote control allows optimisation of the supply air volume Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Home leave operation saves energy during absence Whisper quiet operation: down to 29dBA sound pressure Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Easy installation thanks to automatic air flow adjustment towards nominal air flow rate Builtin drain pump as standard increases reliability of the drain system Heating & Cooling Indoor units FBQ71C FBQ100C FBQ125C FBQ140C Cooling capacity Min./Nom./Max. kw /7.1 / /10.0 / /12.5 / /13.4 / Heating capacity Min./Nom./Max. kw /8.0 / /11.2 / /14.0 / /15.0 / Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 1,047 1,351 1,796 2,226 Energy label Cooling/Heating A/A B/B 300x1,000x x1,400x700 Required ceiling void mm Decoration panel Model BYBS71DJW1 BYBS125DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x1,100x500 55x1,500x500 Weight kg FanExternal static pressure High/Nom. Pa Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 38/32 40/33 41/34 connections Gas OD mm Drain OD mm Outdoor units RZQ71D3V1 RZQ100D9V1 RZQ125D9V1 RZQ140D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010) /30 120/40 120/ /29 38/32 40/ Both liquid and gas pipes 1~ / 50 / ~ / 50/60 / / ~50.0

134 FBQC / RZQB9W1 Concealed ceiling unit with inverter driven fan FBQ100,125,140C RZQ100,125,140B9W1 BRC1E51A Energy efficient units: up to class A energy labels Reduction in power consumption thanks to DC inverter fans Improved comfort thanks to 3step airflow control Maximum external static pressure (ESP) is 120Pa Possibility to change ESP through wired remote control allows optimisation of the supply air volume Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Home leave operation saves energy during absence Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Easy installation thanks to automatic air flow adjustment towards nominal air flow rate Builtin drain pump as standard increases reliability of the drain system Heating & Cooling Indoor units FBQ100C FBQ125C FBQ140C Cooling capacity Min./Nom./Max. kw /10.00/ /12.50/ /14.00/ Heating capacity Min./Nom./Max. kw /11.20/ /14.00/ /16.00/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 1,390 1,955 2,350 Energy label Cooling/Heating A/A B/A C/A 300x1,500x700 Required ceiling void mm Decoration panel Model BYBS125DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm Weight kg FanExternal static pressure High/Nom. Pa Sound power Cooling High dba Sound pressure Cooling High/Low dba 38/32 40/33 41/34 connections Gas OD mm Drain OD mm Power supply Phase;Frequency;Voltage Hz/V Outdoor units RZQ100B9W1 RZQ125B9W1 RZQ140B9W1 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Power supply Phase;Frequency;Voltage Hz;V * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 55x1,500x /40 120/ /32 40/ ~/50/60/ ,345x900x ~ Both liquid and gas pipes 3N~/50/400

135 FBQC / RZQSDV1 Concealed ceiling unit with inverter driven fan FBQ100,125,140C RZQS71DV1 BRC1E51A Reduction in power consumption thanks to DC inverter fans Improved comfort thanks to 3step airflow control Maximum external static pressure (ESP) is 120Pa Possibility to change ESP through wired remote control allows optimisation of the supply air volume Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Home leave operation saves energy during absence Whisper quiet operation: down to 29dBA sound pressure Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Easy installation thanks to automatic air flow adjustment towards nominal air flow rate Builtin drain pump as standard increases reliability of the drain system Heating & Cooling Indoor units FBQ71C FBQ100C FBQ125C FBQ140C Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER COP Annual energy consumption 1,047 1,351 1,796 2,226 Energy label Cooling Heating A A A A A A B B Casing Colour galvanised steel 300x1,000x x1,400x700 Required ceiling void mm Decoration panel Model BYBS71DJW1 BYBS125DJW1 Colour white (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x1,100x500 55x1,500x500 Weight kg FanExternal static High/Nom. Pa pressure 100/30 120/40 120/50 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 38/32 40/33 37/29 38/32 40/33 41/ connections Gas OD mm 15.9 Drain VP25(OD32,ID25) 1~ / 50/60 / /220 Outdoor units RZQS71DV1 RZQS100DV1 RZQS125DV1 RZQS140DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m ~ Both liquid and gas pipes 1~ / 50 /

136 FBQC / RXSJ/F Concealed ceiling unit with inverter driven fan FBQ35,50C RXS35J BRC1E51A Energy efficient units: up to class A energy labels Improved comfort thanks to 3step air flow control Possibility to change ESP via wired remote control allows optimisation of the supply air volume Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Whisper quiet operation: down to 29dBA sound pressure Standard air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation thanks to automatic air flow adjustment towards nominal air flow rate Standard builtin drain pump increases reliability of the drain system Heating & Cooling Indoor units *FBQ35C *FBQ50C FBQ60C Cooling capacity Min./Nom./Max. kw 1.4/3.4/ /5.0/5.6 /5.70/ Heating capacity Min./Nom./Max. kw 1.2/4.0/ /6.0/7.0 /7.00/ Power input Cooling Min./Nom./Max. kw /1.06/ 1.83/2.02/4.50 /1.75/ Heating Min./Nom./Max. kw /1.11/ 0.36/2.05/2.45 /2.05/ EER COP Annual energy consumption kwh Energy label Cooling/Heating A/B B/B A/B 300x700x x1,000x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 Colour White (10Y9/0.5) White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x800x500 55x1,100x500 Weight kg FanExternal static pressure High/Nom. Pa 100/30 100/30 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 37/29 37/29 37/29 R410A connections Gas OD mm Drain OD mm ~ / 50/60 / /220 1~ / 50/60 / /220 Outdoor units *RXS35J *RXS50J RXS60F 550x828x x903x x825x Fan Air flow rate Cooling High/Low m³/min 50.9/45.0 Heating High/Low m³/min 46.3/46.3 Sound power Cooling Nom. dba Sound pressure Cooling High/Low dba 48/44 49/46 48/45 49/46 Operation range Cooling Ambient Min.~Max. CDB 10~46 10~46 Heating Ambient Min.~Max. CWB 15~20 15~18 R410A length Max. OU IU m connections Level difference IU OU Max. m Heat insulation Both liquid and gas pipes Total piping length System Actual m Power supply Phase / Frequency / Voltage Hz/V 1~ / 50 / ~ / 50 / *Note: grey cells contain preliminary data

137 FDQB / RZQD9V1 Concealed ceiling unit FDQ125B RZQ125D9V1 BRC1E51A Up to 150 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Home leave operation saves energy during absence Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Heating & Cooling Indoor units FDQ125B Cooling capacity Min./Nom./Max. kw /12.5/ Heating capacity Min./Nom./Max. kw /14.0/ Power input Cooling Nom. kw 3.96 Heating Nom. kw 3.61 EER COP SEER * Annual energy consumption kwh 1,978 Energy label Cooling/Heating B/A Required ceiling void mm FanExternal static pressure High/Nom./Low Pa Sound power Cooling Nom. dba Sound pressure Cooling High dba Heating Low dba 44.0 connections Gas OD mm Drain OD mm Outdoor units RZQ125D9V1 1,345x900x Fan Air flow rate Cooling Nom. m³/min 100 Heating Nom. m³/min 90 Sound power Cooling Nom. dba 67 Sound pressure Cooling Nom. dba 51 Heating Nom. dba 53 Night quiet mode Level 1 dba 45 Operation range Cooling Ambient Min.~Max. CDB 15.0~50.0 Heating Ambient Min.~Max. CWB 20.0~15.5 length Max. OU IU m 75 connections Level difference IU OU Max. m 30.0 IU IU Max. m 0.5 Heat insulation Both liquid and gas pipes Total piping length System Actual m * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010) x1,400x /150/ ~ / 50 / 230 1~ / 50 /

138 FDQB / RZQB9W1 Concealed ceiling unit FDQ125B RZQ125B9W1 BRC1E51A Up to 150 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Home leave operation saves energy during absence Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Heating & Cooling Indoor units FDQ125B Cooling capacity Min./Nom./Max. kw /12.50/ Heating capacity Min./Nom./Max. kw /14.00/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 2,075 Energy label Cooling/Heating B/A Required ceiling void mm FanExternal static pressure High/Nom./Low Pa Sound power Cooling Nom. dba Sound pressure Cooling High dba Heating Low dba 44.0 connections Gas OD mm Drain OD mm Outdoor units RZQ125B9W1 1,345x900x Fan Air flow rate Cooling Nom. m³/min 99.0 Heating Nom. m³/min Sound power Cooling Nom. dba 66.0 Sound pressure Cooling Nom. dba 50.0 Heating Nom. dba 52.0 Night quiet mode Level 1 dba 45 Operation range Cooling Ambient Min.~Max. CDB 15.0~50.0 Heating Ambient Min.~Max. CWB 20.0~15.5 length Max. OU IU m 75 connections Level difference IU OU Max. m 30.0 IU IU Max. m 0.5 Heat insulation Both liquid and gas pipes Total piping length System Actual m * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010) x1,400x /150/ ~ / 50 / 230 3N~ / 50 / 400

139 FDQB / RZQSDV1 Concealed ceiling unit FDQ125B RZQS125DV1 BRC1E51A Up to 150 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Home leave operation saves energy during absence Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Heating & Cooling Indoor units FDQ125B Cooling capacity Min./Nom./Max. kw /12.5/ Heating capacity Min./Nom./Max. kw /14/ Power input Cooling Nom. kw 4.30 Heating Nom. kw 3.97 EER COP Annual energy consumption kwh Energy label Cooling/Heating C/B Required ceiling void mm FanExternal static pressure High/Nom./Low Pa Sound power Cooling Nom. dba Sound pressure Cooling High dba Heating Low dba 44.0 connections Gas OD mm Drain OD mm Outdoor units RZQS125DV1 1,170x900x Fan Air flow rate Cooling Nom. m³/min 100 Heating Nom. m³/min 90 Sound power Cooling Nom. dba 67 Sound pressure Cooling Nom. dba 51 Heating Nom. dba 53 Night quiet mode Level 1 dba 49 Operation range Cooling Ambient Min.~Max. CDB 5.0~46 Heating Ambient Min.~Max. CWB 15~15.5 length Max. OU IU m 50 connections Level difference IU OU Max. m 30 IU IU Max. m 0.5 Heat insulation Both liquid and gas pipes Total piping length System Actual m 350x1,400x /150/ ~ / 50 / 230 1~ / 50 /

140 FDQB / RZQC Concealed ceiling unit FDQ200,250B RZQ200,250C BRC1E51A Up to 250 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Up to 26.4 kw in heating mode Home leave operation saves energy during absence Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Heating & Cooling Indoor units FDQ200B FDQ250B Cooling capacity Min./Nom./Max. kw /20.0/ /24.1/ Heating capacity Min./Nom./Max. kw /23.0/ /26.4/ Power input Cooling Nom. kw Heating Nom. kw EER COP Annual energy consumption kwh 3,115 4,290 Energy label Cooling/Heating A/B C/C Required ceiling void mm FanExternal static pressure High/Nom./Low Pa Sound power Cooling Nom. dba Sound pressure Cooling High dba Heating Low dba connections Gas OD mm Drain OD mm Outdoor units RZQ200C RZQ250C 1,680x930x Fan Air flow rate Cooling Nom. m³/min 171 Heating Nom. m³/min 171 Fan External Max. Pa static pressure 78 Sound power Cooling Nom. dba Operation range Cooling Ambient Min.~Max. CDB 5.0~46.0 Heating Ambient Min.~Max. CWB 15.0~15.0 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m 450x1,400x /250/ ~ / 50 / N~ / 50 /

141 FAQB / RZQD3V1/D9V1 Wall mounted unit RZQ71D3V1 FAQ71B BRC1E51A BRC7E618 Can be installed in both new and existing buildings Vertical autoswing function moves the discharge flaps up and down for efficient air distribution throughout the room 5 different discharge angles can be programmed via the remote control Home leave operation saves energy during absence Both horizontal flaps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit Heating & Cooling Indoor units FAQ71B FAQ100B Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER Annual energy consumption kwh 1,141 1,645 Energy label Cooling/Heating B/B Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain OD mm 290x1,050x x1,570x / / / / / / / / x26 1~ / 50 / Outdoor units RZQ71D3V1 RZQ100D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet Level 1 dba mode Operation range Cooling Ambient Min.~Max. CDB 15.0~50.0 Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m Both liquid and gas pipes 1~ / 50 /

142 FAQB / RZQB9W1 Wall mounted unit FAQ71B RZQ100B9W1 BRC1E51A BRC7E618 Can be installed in both new and existing buildings Vertical autoswing function moves the discharge flaps up and down for efficient air distribution throughout the room 5 different discharge angles can be programmed via the remote control Energy efficient: up to class A energy labels Home leave operation saves energy during absence Both horizontal flaps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit Heating & Cooling Indoor units FAQ100B Cooling capacity Min./Nom./Max. kw /10.00/ Heating capacity Min./Nom./Max. kw /11.20/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER Annual energy consumption kwh Energy label Cooling/Heating A/C Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 45.0/41.0 connections Gas OD mm Drain OD mm Outdoor units RZQ100B9W1 1,345x900x Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba 65.0 Sound pressure Cooling Nom. dba 49.0 Heating Nom. dba 51.0 Night quiet mode Level 1 dba 45 Operation range Cooling Ambient Min.~Max. CDB 15.0~50.0 Heating Ambient Min.~Max. CWB 20.0~15.5 length Max. OU IU m 75 connections Level difference IU OU Max. m 30.0 IU IU Max. m 0.5 Heat insulation Both liquid and gas pipes Total piping length System Actual m 360x1,570x / / / ~ / 50 / N~ / 50 /

143 FAQB / RZQSDV1 Wall mounted unit RZQS71DV1 FAQ71B BRC1E51A BRC7E618 Can be installed in both new and existing buildings Vertical autoswing function moves the discharge flaps up and down for efficient air distribution throughout the room 5 different discharge angles can be programmed via the remote control Home leave operation saves energy during absence Both horizontal flaps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit Heating & Cooling Indoor units FAQ71B FAQ100B Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ Power input Cooling Nom. kw Heating Nom. kw EER COP 3.21 Annual energy consumption kwh 1,220 1,779 Energy label Cooling/Heating C/C Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain OD mm 290x1,050x x1,570x / / / / / / / / ~ / 50 / Outdoor units RZQS71DV1 RZQS100DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m ~ Both liquid and gas pipes 1~ / 50 /

144 FHQGC / RZQGL Ceiling suspended unit OPTIMIZED FOR SEASONAL EFFICIENCY FHQG71C RZQG71L BRC1E51A Energy efficient units: up to class A energy labels Improved Seasonal efficiency SEER: up to 4.53! (PrEN14825 inquiry version 2010) Seasonal efficiency, optimized for all seasons. Can be installed in both new and existing buildings Ideal solution for shops, restaurants or offices without false ceilings The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season. The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable environment and offers great savings in energy consumption to shop, restaurant and office owners Heating & Cooling Indoor units * FHQG71C * FHQG100C * FHQG125C * FHQG140C Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.0/ /14.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /16.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh 975 1,305 1,785 2,325 Energy label Cooling/Heating A/A A/ B/A Casing Colour Fresh white (6.5Y 9.5/0.5) Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba connections Liquid mm Gas mm Drain mm Outdoor units * RZQG71L * RZQG100L * RZQG125L * RZQG140L 990x940x320 1,430x940x320 Fan Air flow rate Cooling m³/min Heating Sound power Cooling Heating Sound pressure m³/min dba dba Cooling Nom. dba Heating Nom. dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20~15.5 connections Gas OD mm Drain OD mm length Max. OU IU m Level difference IU OU Max. m Total piping length System Actual m * pren14825 (inquiry version 2010) 235x1,270x x1,590x VP20(OD 26) 1~ / 50 / ~ ~ / 50 /

145 FHQGC / RZQD3V1/D9V1 Ceiling suspended unit FHQG71C RZQ100,125,140D9V1 BRC1E51A Energy efficient units: up to class A energy labels Can be installed in both new and existing buildings Ideal solution for shops, restaurants or offices without false ceilings The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space Heating & Cooling Indoor units *FHQG71C *FHQG100C *FHQG125C *FHQG140C Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ /14.0/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ /16.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER* Annual energy consumption kwh 1,020 1,470 2,036 2,490 Energy label Cooling/Heating A/A B/A Casing Colour Fresh white (6.5Y 9.5/0.5) Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Refrigerant Type connections Drain OD mm Outdoor units *RZQ71D3V1 *RZQ100D9V1 *RZQ125D9V1 *RZQ140D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB 15.0~50.0 Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping System Actual m length * pren14825 (inquiry version 2010) 235x1,270x x1,590x R410A 1~ / 50 / Both liquid and gas pipes 143 1~ / 50 / *Note: grey cells contain preliminary data

146 FHQB / RZQD3V1/D9V1 Ceiling suspended unit FHQ125B RZQ100,125D9V1 BRC1E51A BRC7EA63W Can be installed in both new and existing buildings Wider air discharge thanks to Coanda effect: up to 100 degrees 100 Home leave operation saves energy during absence Air flow distribution for ceiling heights up to 3.8m without loss of capacity The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service Heating & Cooling Indoor units FHQ71B FHQ100B FHQ125B Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER Annual energy consumption kwh , , * 2,119 Energy label Cooling/Heating B/D B/C C/C Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 9.52 Gas OD mm 15.9 Drain OD mm VP20(I.D.20/O.D.26) 1~ / 50 / Outdoor units RZQ71D3V1 RZQ100D9V1 RZQ125D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 195x1,160x x1,400x x1,590x /51 58/53 60/55 55/51 58/53 60/55 39/35 42/37 44/39 39/35 42/37 44/ ~ Both liquid and gas pipes 1~ / 50 /

147 FHQB / RZQB9W1 Ceiling suspended unit FHQ125B RZQ100,125B9W1 BRC1E51A BRC7EA63W Can be installed in both new and existing buildings Wider air discharge thanks to Coanda effect: up to 100 degrees 100 Home leave operation saves energy during absence Air flow distribution for ceiling heights up to 3.8m without loss of capacity The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space Heating & Cooling Indoor units FHQ100B FHQ125B Cooling capacity Min./Nom./Max. kw /10.00/ /12.50/ Heating capacity Min./Nom./Max. kw /11.20/ /14.00/ Power input Cooling Nom. kw Heating Nom. kw EER COP 3.11 SEER Annual energy consumption kwh , * 2,225 Energy label Cooling/Heating C/D B/D Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 9.52 Gas OD mm 15.9 Drain OD mm VP20(I.D.20/O.D.26) 1~ / 50 / Outdoor units RZQ100B9W1 RZQ125B9W1 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 195x1,400x Both liquid and gas pipes 3N~ / 50 / x1,590x /53 60/55 58/53 60/55 42/37 44/39 42/37 44/39 1,345x900x ~50.0

148 FHQB / RZQSDV1 Ceiling suspended unit FHQ125B RZQS100,125DV1 BRC1E51A BRC7EA63W Can be installed in both new and existing buildings Wider air discharge thanks to Coanda effect: up to 100 degrees 100 Home leave operation saves energy during absence Air flow distribution for ceiling heights up to 3.8m without loss of capacity The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service Heating & Cooling Indoor units FHQ71B FHQ100B FHQ125B Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP Annual energy consumption kwh 1,254 1,779 2,273 Energy label Cooling/Heating C/D D/D Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 9.52 Gas OD mm 15.9 Drain OD mm VP20(I.D.20/O.D.26) 1~ / 50 / Outdoor units RZQS71DV1 RZQS100DV1 RZQS125DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m 195x1,160x x1,400x x1,590x /51 58/53 60/55 55/51 58/53 60/55 39/35 42/37 44/39 39/35 42/37 44/ ~ Both liquid and gas pipes 1~ / 50 /

149 FHQB / RXSJ/F Ceiling suspended unit FHQ35,50B RXS35J BRC1E51A BRC7EA63W Can be installed in both new and existing buildings Wider air discharge thanks to Coanda effect: up to Air flow distribution for ceiling heights up to 3.8m without capacity loss The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space Heating & Cooling Indoor units *FHQ35B *FHQ50B FHQ60B Cooling capacity Min./Nom./Max. kw 1.4/3.4/ /5.0/ /5.7/6.0 Heating capacity Min./Nom./Max. kw 1.2/4.0/ /6.0/ /7.2/8.0 Power input Cooling Min./Nom./Max. kw /1.05/ 0.44/1.83/ /2.15/2.23 Heating Min./Nom./Max. kw /1.11/ 0.40/2.05/ /2.49/2.75 EER COP Annual energy consumption kwh ,075 Energy label Cooling/Heating A/B D/D D/D Casing Colour White White 195x960x x1,160x680 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 37/32 38/33 39/33 R410A connections Gas OD mm Drain OD mm VP20(ID20/OD26) VP20(ID20/OD26) 1~ / 50 / ~ / 50 / /48 54/49 55/49 53/48 54/49 55/49 37/32 38/33 39/33 Outdoor units *RXS35J *RXS50J RXS60F 550x828x x903x x825x Fan Air flow rate Cooling High/Low m³/min 50.9/45.0 Heating High/Low m³/min 46.3/46.3 Sound power Cooling Nom. dba Sound pressure Cooling High/Low dba 48/44 49/46 48/45 49/46 Operation range Cooling Ambient Min.~Max. CDB 10~46 10~46 Heating Ambient Min.~Max. CWB 15~20 15~18 R410A length Max. OU IU m connections Level difference IU OU Max. m Heat insulation Both liquid and gas pipes Total piping length System Actual m 1~ / 50 / ~ / 50 / *Note: grey cells contain preliminary data

150 FUQB / RZQD3V1/D9V1 4way blow ceiling suspended unit FUQ71B RZQ71D3V1 BRC1E51A BRC7CA528W Can be installed in both new and existing buildings Air can be discharged in any of 4 directions Home leave operation saves energy during absence Autoswing function ensures efficient air and temperature distribution Air can be discharged at 5 different angles between 0 and 60 degrees Possibility to shut 1 or 2 flaps for easy installation in corners Air flow distribution for ceiling heights up to 3.5m without loss of capacity Drainup pump with 500mm lift fitted as standard Heating & Cooling Indoor units FUQ71B FUQ100B FUQ125B Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER * Annual energy consumption kwh 1,105 1,484 1,978 Energy label Cooling/Heating A/B A/C B/C Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain OD mm Outdoor units RZQ71D3V1 RZQ100D9V1 RZQ125D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m * This value is given only as indication as class 125 is not in scope for pren14825 (inquiry version 2010). 165x895x x895x / / /55 56/ / /55 40/ / /39 40/ / / Both liquid and gas pipes 1~ / 50 / x26 1~ / 50 / ~50.0

151 FUQB / RZQB9W1 4way blow ceiling suspended unit RZQ100,125B9W1 FUQ100,125B BRC1E51A BRC7CA528W Can be installed in both new and existing buildings Air can be discharged in any of 4 directions Home leave operation saves energy during absence Autoswing function ensures efficient air and temperature distribution Air can be discharged at 5 different angles between 0 and 60 degrees Possibility to shut 1 or 2 flaps for easy installation in corners Air flow distribution for ceiling heights up to 3.5m without loss of capacity. Drainup pump with 500mm lift fitted as standard Heating & Cooling Indoor units FUQ100B FUQ125B Cooling capacity Min./Nom./Max. kw /10.00/ /12.50/ Heating capacity Min./Nom./Max. kw /11.20/ /14.00/ Power input Cooling Nom. kw Heating Nom. kw EER COP SEER Annual energy consumption kwh 1,560 2,025 Energy label Cooling/Heating A/B B/C Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain OD mm Outdoor units RZQ100B9W1 RZQ125B9W1 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m 230x895x / / / / / / / / x26 1~ / 50 / ,345x900x ~ Both liquid and gas pipes 3N~ / 50 /

152 FVQB / RZQSDV1 Floor standing unit FVQB RZQS100,125DV1 Ideal solution for shops, restaurants or offices without false ceilings Very efficient for use in rooms with high ceilings Can be installed in both new and existing buildings Dual air discharge flow for better air distribution Heating & Cooling Indoor units FVQ71B FVQ100B FVQ125B Cooling capacity Min./Nom./Max. kw /7.1/ /10.0/ /12.5/ Heating capacity Min./Nom./Max. kw /8.0/ /11.2/ /14.0/ Power input Cooling Nom. kw Heating Nom. kw EER COP Annual energy consumption kwh 1,265 1,779 2,225 Energy label Cooling/Heating C/C Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain OD mm Outdoor units RZQS71DV1 RZQS100DV1 RZQS125DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m 1,850x600x270 1,850x600x /48 60/54 62/56 54/48 60/54 62/56 42/36 48/42 50/44 42/36 48/42 50/ ~ / 50 / ~ Both liquid and gas pipes 1~ / 50 /

153

154 CMSQA Commercial multi system Especially developed for light commercial applications (shops, restaurants, bars, hairdressers, small offices or 2storey areas) where multi systems are required High efficiency: COP ranges up to 4.1 Asymmetric combination is allowed: combination of different indoor units with different capacities is possible Individual control: up to 4 indoor units can be controlled individually Maximum piping length up to 200m and difference (outdoor unitindoor unit) up to 30m Possibility to install the unit on the roof, placed against an outside wall or even indoors Heating & Cooling Indoor units FMCQ50A8 FMCQ60A8 FMCQ71A8 FMCQ100A8 FMCQ125A8 Cooling capacity Nom. kw Heating capacity Nom. kw Power input 50Hz Cooling Nom. kw Heating Nom. kw x840x x840x x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High/Nom. dba Sound pressure Cooling High/Low dba 50x950x950 / 50x950x950 / 130x950x / 5.5 / / 52/ 55/ 58/ 61/ 33/28 34/29 38/32 41/33 44/34 33/28 36/30 38/32 42/34 44/34 connections Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (I.D. 25/O.D. 32) 9.52/15.9/VP25 (I.D. 25/O.D. 32) 1~ / 50/60 / /220 1 Pure white standard panel with grey louvers / 2 Pure white standard panel with louvers / 3 Pure white auto cleaning panel Indoor units FMDQ50B FMDQ60B FMDQ71B FMDQ100B FMDQ125B Cooling capacity Nom. kw Heating capacity Nom. kw Power input 50Hz Cooling Nom. kw Heating Nom. kw x700x x1,000x x1,400x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm Weight kg FanExternal static High Pa pressure Nom. Pa Sound power Cooling Nom. dba Sound pressure Cooling High/Low dba 55x800x500 55x1,100x500 55x1,500x /29 37/30 38/32 40/33 37/29 37/30 38/32 40/33 connections Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /

155 CONNECTABLE OUTDOOR UNIT CMSQ200A CMSQ250A Capacity range HP 8 10 Cooling capacity Nom. kw Heating capacity Nom. kw Power input 50Hz Cooling Nom. kw Heating Nom. kw EER COP Maximum number of connectable indoor units 4 1,680x635x765 1,680x930x FanAir flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Operation range Cooling Min.~Max. CDB 5.0~43.0 Heating Min.~Max. CWB 20.0~15.0 connections Gas OD mm Total piping length System Actual m Level difference OU IU m N~ / 50 / 400 Outdoor unit Concealed ceiling unit Individual control Round flow cassette 153

156 RZQD3V1/ D9V1/B9W1 Twin, triple, double twin Optimized for Seasonal efficiency Suits computer room applications Reuse of existing R22 or R407C piping Up to 20 C in heating mode Standard night quiet mode Maximum piping length up to 75m Heating & Cooling CONNECTABLE INDOOR UNITS Indoor units FCQ35C8 FCQ50C8 FCQ60C8 FCQ71C8 204x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm Weight kg Sound power Cooling High dba Sound pressure Cooling High/Low dba 50x950x950 / 50x950x950 / 130x950x / 5.5 / /27 33/28 31/27 33/28 34/ connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel CONNECTABLE INDOOR UNITS Indoor units FCQH71D8 246x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba 54 Sound pressure Cooling High/Low dba 36/28 36/28 connections 9.52 Gas OD mm 15.9 Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel 154

157 CONNECTABLE INDOOR UNITS Indoor units FFQ35BV FFQ50BV FFQ60BV 286x575x Decoration panel Model BYFQ60BAW1 Colour White (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 Weight kg 2.7 Sound power Cooling High dba Sound pressure Cooling High/Low dba 32.0/ / / / / /32.0 connections Gas OD mm Drain ~ / 50 / 230 CONNECTABLE INDOOR UNITS Indoor units FBQ35C FBQ50C FBQ60C FBQ71C 300x700x x1,000x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x800x500 55x1,100x500 Weight kg FanExternal static High/Nom. Pa pressure 100/30 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 37/29 connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 CONNECTABLE INDOOR UNITS Indoor units FHQ35B FHQ50B FHQ60B Casing Colour White 195x960x x1,160x680 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 6.35 Gas OD mm Drain VP20 (I.D. 20/O.D. 26) 1~ / 50 / /48 54/49 55/49 53/48 54/49 55/49 37/32 38/33 39/33 37/32 38/33 39/33 CONNECTABLE INDOOR UNITS Indoor units FUQ71B Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 40/35 connections 9.52 Gas OD mm 15.9 Drain I.D. 20/O.D. 26 1~ / 50 / x895x / /51 40/35 155

158 CONNECTABLE INDOOR UNITS Indoor units FAQ71B Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 43.0/37.0 connections 9.52 Gas OD mm 15.9 Drain VP13 (I.D. 13/O.D. 18) 1~ / 50 / x1,050x / / /37.0 CONNECTABLE OUTDOOR UNITS Outdoor units RZQ71D3V1 RZQ100D9V1 RZQ125D9V1 RZQ140D9V1 770x900x320 1,345x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m ~ Both liquid and gas pipes 1~ / 50 / CONNECTABLE OUTDOOR UNITS Outdoor units RZQ100B9W1 RZQ125B9W1 RZQ140B9W1 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 20.0~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m 1,345x900x ~ Both liquid and gas pipes 3N~ / 50 /

159 RZQC Twin, triple, double twin Three phase Reuse of existing R22 or R407C piping Down to 15 C in heating mode Standard night quiet mode Maximum piping length up to 100m Maximum installation height difference up to 30m Heating & Cooling CONNECTABLE INDOOR UNITS Indoor units FCQ50C8 FCQ60C8 FCQ71C8 FCQ100C8 FCQ125C8 204x840x x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba Sound pressure Cooling High/Low dba 31/27 33/28 37/32 41/35 31/27 33/28 34/28 37/32 41/35 connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / / Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel CONNECTABLE INDOOR UNITS Indoor units FCQH71D8 FCQH100D8 FCQH125D8 246x840x x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba Sound pressure Cooling High/Low dba 36/28 45/32 45/36 36/28 45/32 45/36 connections 9.52 Gas OD mm 15.9 Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / / Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel 157

160 CONNECTABLE INDOOR UNITS Indoor units FFQ50BV FFQ60BV 286x575x Decoration panel Model BYFQ60BAW1 Colour White (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 Weight kg 2.7 Sound power Cooling High dba Sound pressure Cooling High/Low dba 36.0/ / / /32.0 connections Gas OD mm Drain ~ / 50 / 230 CONNECTABLE INDOOR UNITS Indoor units FBQ50C FBQ60C FBQ71C 300x700x x1,000x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x800x500 55x1,100x500 Weight kg FanExternal static pressure High/Nom. Pa 100/30 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 37/29 connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 CONNECTABLE INDOOR UNITS Indoor units FHQ50B FHQ60B FHQ71B FHQ100B FHQ125B Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain VP20 (I.D. 20/O.D. 26) 1~ / 50 / x960x x1,160x x1,400x x1,590x /49 55/49 55/51 58/53 60/55 54/49 55/49 55/51 58/53 60/55 38/33 39/33 39/35 42/37 44/39 38/33 39/33 39/35 42/37 44/39 CONNECTABLE INDOOR UNITS Indoor units FUQ71B FUQ100B FUQ125B Casing Colour White 165x895x x895x895 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 9.52 Gas OD mm Drain I.D. 20/O.D. 26 1~ / 50 / / / /55 56/ / /55 40/ / /39 40/ / /39 158

161 CONNECTABLE INDOOR UNITS Indoor units FAQ71B FAQ100B Casing Colour White 290x1,050x x1,570x200 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections 9.52 Gas OD mm 15.9 Drain VP13 (I.D. 13/O.D. 18) VP20 (I.D. 20/O.D. 26) 1~ / 50 / / / / / / / / /41.0 CONNECTABLE INDOOR UNITS Indoor units FDQ125B 350x1,400x662 Required ceiling void mm FanExternal static pressure High/Nom./Low Pa 150/150/150 Sound power Cooling Nom. dba 75.0 Sound pressure Cooling High dba 44.0 Heating Low dba 44.0 connections Gas OD mm Drain ~ / 50 / 230 CONNECTABLE OUTDOOR UNITS Outdoor units RZQ200C RZQ250C 1,680x930x Fan Air flow rate Cooling Nom. m³/min 171 Heating Nom. m³/min 171 Fan External static pressure Max. Pa 78 Sound power Cooling Nom. dba Operation range Cooling Ambient~Min.~Max. CDB 5.0~46.0 Heating Ambient~Min.~Max. CWB 15.0~15.0 length Max. OU IU m connections Level difference IU OU Max. m Total piping length System Actual m 100 3N~ / 50 /

162 RZQSDV1 Twin, triple, double twin Single phase Down to 15 C in heating mode Standard night quiet mode Maximum piping length up to 50m Maximum installation height difference up to 30m Heating & Cooling CONNECTABLE INDOOR UNITS Indoor units FCQ35C8 FCQ50C8 FCQ60C8 FCQ71C8 204x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba Sound pressure Cooling High/Low dba 31/27 33/28 31/27 33/28 34/ connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel CONNECTABLE INDOOR UNITS Indoor units FCQH71D8 246x840x Decoration panel Model BYCQ140CW1 1 / BYCQ140CW1W 2 / BYCQ140CGW1 3 Colour Pure White(RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 Weight kg 5.5 / 5.5 / 11.5 Sound power Cooling High dba 54 Sound pressure Cooling High/Low dba 36/28 36/28 connections 9.52 Gas OD mm 15.9 Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel 160

163 CONNECTABLE INDOOR UNITS Indoor units FFQ35BV FFQ50BV FFQ60BV 286x575x Decoration panel Model BYFQ60BAW1 Colour White (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 Weight kg 2.7 Sound power Cooling High dba Sound pressure Cooling High/Low dba 32.0/ / / / / /32.0 connections Gas OD mm Drain ~ / 50 / 230 CONNECTABLE INDOOR UNITS Indoor units FAQ71B Casing Colour White Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba 43.0/37.0 connections 9.52 Gas OD mm 15.9 Drain VP13 (I.D. 13/O.D. 18) 1~ / 50 / x1,050x / / /37.0 CONNECTABLE INDOOR UNITS Indoor units FBQ35C FBQ50C FBQ60C FBQ71C 300x700x x1,000x700 Required ceiling void mm Decoration panel Model BYBS45DJW1 BYBS71DJW1 Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x800x500 55x1,100x500 Weight kg FanExternal static pressure High/Nom. Pa 100/30 Sound power Cooling High dba Sound pressure Cooling High/Low dba 37/29 37/29 connections Gas OD mm Drain VP25 (O.D. 32 / I.D. 25) 1~ / 50/60 / /220 CONNECTABLE INDOOR UNITS Indoor units FHQ35B FHQ50B FHQ60B FHQ71B Casing Colour White 195x960x x1,160x680 Sound power Cooling High/Low dba Sound pressure Cooling High/Low dba connections Gas OD mm Drain VP20 (I.D. 20/O.D. 26) 1~ / 50 / /48 54/49 55/49 55/51 53/48 54/49 55/49 55/51 37/32 38/33 39/33 39/35 37/32 38/33 39/33 39/35 161

164 CONNECTABLE OUTDOOR UNITS Outdoor units RZQS71DV1 RZQS100DV1 RZQS125DV1 RZQS140DV1 770x900x320 1,170x900x320 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power Cooling Nom. dba Sound pressure Cooling Nom. dba Heating Nom. dba Night quiet mode Level 1 dba Operation range Cooling Ambient Min.~Max. CDB Heating Ambient Min.~Max. CWB 15~15.5 connections length Max. OU IU m Level difference IU OU Max. m IU IU Max. m Heat insulation Total piping length System Actual m ~ Both liquid and gas pipes 1~ / 50 /

165

166 UATYQBY1 Rooftop heat pump UATYQBY1 High efficiency models thanks to the combination of high efficient and reliable scroll compressors and R410A refrigerant. Refrigerant is factory precharged to ensure clean and efficient operation Plug and Play installation: the single unit configuration requires no additional piping work as both the indoor and outdoor sides are preconnected Extended operating range: Cooling: 0 C to 52 C as standard Heating: 15 C to 20 C as standard Convertible return and supply air: fan can be mounted in two directions Belt driven fan enables air volume and static pressure to be adjusted as required New control panel offered as standard Integration to bigger Daikin control system via option Smoke detector contact Electric heater connection The flat top design of the unit allows for maximum utilization of warehouse and container space Coil with anticorrosion treatment PLUG AND PLAY INSTALLATION Heating & Cooling Indoor units UATYQ250BY1 UATYQ350BY1 UATYQ450BY1 UATYQ550BY1 UATYQ600BY1 UATYQ700BY1 Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER COP Evaporator Air flow rate Cooling l/s , , , , , ,917 External static pressure Pa Evaporator piping Condensation OD mm connections drain size 25.4 Condenser 1,150x1,638x2,063 1,028x2,209x2,113 1,130x2,209x2,113 1,048x2,209x2,670 1,302x2,209x2,670 1,454x2,209x2, Casing Colour Light grey Material Electrogalvanised mild steel Operation range Cooling Min.~Max. CDB 0~52 Heating Min.~Max. CDB 15~20 Sound power Nom. dba ~ / 50 /

167 UATYPAY1 Rooftop heat pump UATYPAY1 Plug and Play installation: the single unit configuration requires no additional piping work as both the indoor and outdoor sides are preconnected Refrigerant is factory precharged to ensure clean and efficient operation The air volume and static pressure required can be adjusted according to the requirement because of the use of a belt driven fan The flat top design of the unit allows for maximum utilization of warehouse and container space. High efficiency and reliable scroll compressor Coil with anticorrosion treatment Heating & Cooling Indoor units UATYP700AY1 UATYP850AY1 UATYPC10AY1 UATYPC12AY1 Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER COP Evaporator Air flow rate Cooling m³/min External static pressure Pa 294 Evaporator piping Condensation OD mm connections drain size 25.4 Condenser Dimensions Unit HxWxD mm 1,735x2,250x2,800 1,974x2,252x3,180 1,200 1,350 1,510 1,600 Casing Colour Light grey Material Electrogalvanised mild steel Air flow rate Cooling m³/min 566 Operation range Cooling Min.~Max. CDB 20~46 Heating Min.~Max. CWB 15~20 Sound power Nom. dba Refrigerant Type R407C 3~ / 50 /

Europe s new energy label: raising the bar on energy efficiency

Europe s new energy label: raising the bar on energy efficiency Product ortfolio 2013 Residential commercial industrial solutions Europe s new energy label: raising the bar on energy efficiency To realise its challenging 20-20-20 environmental goals, Europe is imposing

More information

Pure air. because Daikin cares

Pure air. because Daikin cares Pure air because Daikin cares MCK75J MC70L Why choose a Daikin air purifier? 3 Increased air quality with the Daikin streamer technology 4 Air purification and humidification 8 Additional comfort 10 User-friendly

More information

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER DON'T With the COMPROMISE emerging trend ON HEALTH towards AND double COMFORT. storey homes BREATHE on smaller EASY blocks, WITH DAIKIN S the AIR compact

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling Ceiling suspended unit Energy label:» Up to class A Seasonal efficiency, optimized for all seasons Heat pump system Installation possible in new and existing buildings

More information

Cooling Only & Heat Pump

Cooling Only & Heat Pump Cooling Only & Heat Pump Daikin is renowned for its pioneering approach to product development and the unrivalled quality and versatility of its integrated solutions. From the efficiency of our compressors

More information

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping Heating & Cooling OPTIMIZED FOR SEASONAL EFFICIENCY INDOOR UNIT FCQG71E FCQG100E FCQG125E FCQG140E Cooling capacity Nom. kw 7.1 3 10.0 3 12.0 14.0 3 Heating capacity Nom. kw 8.0 4 11.2 4-16 4 Power input

More information

Pure air. Because Daikin cares

Pure air. Because Daikin cares Pure air Because Daikin cares contents Daikin: a tradition of caring 2 Why buy an air purifier? 4 What is the Daikin streamer technology? 5 Enhanced technology 6 Features 8 Main specifications 11 Daikin:

More information

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT Air Purifiers Cleaner fresher healthier air A Daikin air purifier improves the quality of your air indoors,

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e F U L L R A N G E A C L A S S E N E R G Y L A B E L Seasonal efficiency, optimized for all seasons Heat pump system Round flow principle:

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Wall mounted unit SEER and SCOP up to A ++ Discreet, modern design Whisper quiet in operation The right indoor for the right room www.daikin.eu FTXS20-25K/CTXS15-35K

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling Heating All seasons Climate comfort Catalogue Heating Air conditioning Applied Systems Refrigeration Heating - Domestic hot water - Cooling Durable & efficient energy solutions for residential use Heating

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 systems High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma

More information

Water cooled VRV IV W-series

Water cooled VRV IV W-series Water cooled VRV IV W-series Ideal for high rise buildings, using water as heat source Unified range for heat pump & heat recovery and standard & geothermal series 22 Indoor units VRV type indoor units

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling Ceiling Suspended Cassette»» Energy label:» Up to class A»» Heat pump system»» Seasonal inverter technology»» The ideal solution» for larger rooms»» Can be installed

More information

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS TM WALL-MOUNTED HEAT PUMP Up to 26.1 SEER / 11.0 HSPF / 15.8 EER INVERTER, VARIABLE-SPEED COMPRESSOR QUATERNITY Series TM Discreet wall-mounted unit

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces The best of two worlds united Heating & Cooling > heating & cooling in one Quiet and discrete, Nexura offers you the best in heating and cooling, in

More information

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Information for end users. Floor standing units. 24/7 comfort in a contemporary package Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant

More information

Split Type System. Air to Water Heat Pump

Split Type System. Air to Water Heat Pump Split Type System Air to Water Heat Pump EXPERTISE AND INNOVATION Daikin Altherma offers complete flexibility for new construction and deep energy refurbishment projects. Using a low temperature hydronic

More information

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump The natural hoice installer leaflet DAikin Altherma low temperature heat pump Best seasonal efficiencies, providing the highest savings on running costs excellent COP ratings for incentive and certification

More information

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Cooling only INDOOR UNITS FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Capacity cooling min~nom~max kw 1.3~2.0~2.8 1.3~2.5~3.2 1.4~3.5~4.0 1.7~4.2~5.0 1.7~5.0~5.3 1.7~6.0~6.7 2.3~7.1~8.5 Power

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Wall mounted unit SEER up to A++ Discreet, modern design Whisper quiet in operation The right indoor for the right room Heat pump system www.daikin.eu FTXS-20-25K/CTXS-15-35K

More information

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI PART 2 - URURU MULTI MULTI SYSTEM The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort heating, cooling humidification and fresh air ventilation. Designed primarily for two

More information

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Information for end users. Floor standing units. 24/7 comfort in a contemporary package Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Seasonal efficiency, smart use of energy The EU wants to make people aware of what units

More information

VRV The total solution. Integrated Climate Control

VRV The total solution. Integrated Climate Control VRV The total solution Integrated Climate Control Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated climate control

More information

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K Designed colder climates for AIR TO AIR HEAT PUMPS FTXS-20-25K FTXS35-42-50K Optimised heating solutions down to -25 C outdoor temperatures Prestigious design Prevents winter freezing in summer homes Whisper

More information

PHOTOCATALYTIC AIR CLEANER

PHOTOCATALYTIC AIR CLEANER EPCE03-16 PHOTOCATALYTIC AIR CLEANER MC704VM Clean air is essential for a comfortable environment Table of contents 4 01 Antibacterial 5 02 Photocatalytic deodorising power 6 03 Impressive air flow 3 7

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Multi model application For residential and light commercial applications Energy efficient heating system Connect up to 9 indoor units Low energy bills and low CO 2 emissions

More information

Pure comfort & design

Pure comfort & design Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling

More information

EDAU Air Purifiers. Engineering Data MC70LPVM

EDAU Air Purifiers. Engineering Data MC70LPVM EDAU01-0713 Air Purifiers Engineering Data TABLE OF CONTENTS 1 Features.......................... 2 Key Features....................... 2 Streamer Technology................. 2 Clean Air..........................

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Reduced power consumption thanks to DC inverter fan

More information

office building. Seasonal efficiency is a new energy efficiency measure that will be the standard as of

office building. Seasonal efficiency is a new energy efficiency measure that will be the standard as of Energy efficiency is no longer a blind spot. Find out more on www.daikin.eu Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende ECPEN12-500_P2

More information

Daikin Altherma Low Temperature monobloc heat pump

Daikin Altherma Low Temperature monobloc heat pump Information for installers Daikin Altherma Low Temperature monobloc heat pump The natural choice Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Our broad experience,

More information

THE HEAT PUMP CHOICE OF PROFESSIONALS

THE HEAT PUMP CHOICE OF PROFESSIONALS THE HEAT PUMP CHOICE OF PROFESSIONALS T H E E N E R G Y E F F I C I E N T H E AT I N G S Y S T E M TIME FOR ENERGY EFFICIENT AND INNOVATIVE SOLUTIONS Expectations of consumers are changing. With the high

More information

where innovation meets creativity

where innovation meets creativity where innovation meets creativity Stylish wall mounted unit Designed for comfort With more than 90 years of experience in air conditioning and climate control solutions, Daikin combines the best of design

More information

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates Optimised for heating Designed for living 4 Main features 6 Innovation in action 8 Indoor units 12 Wall mounted units Daikin Emura FTXG-LW/S

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of

More information

Daikin leads the way:

Daikin leads the way: Daikin leads the way: Offering a full range of light commercial products optimised for seasonal efficiency All Seasons Climate comfort Heating Air Conditioning Applied Systems Refrigeration Daikin leads

More information

Air Purifiers. Technical Data MC70L

Air Purifiers. Technical Data MC70L Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Single Unit MC70L TABLE OF CONTENTS MC70L Features.............................................................

More information

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort Daikin Sensira R-32 Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more

More information

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating

RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates. Optimised for heating RESIDENTIAL AIR TO AIR HEAT PUMPS Designed for colder climates Optimised for heating Designed for living 4 Main features 6 Innovation in action 8 Indoor units 12 Wall mounted units Daikin Emura FTXG-LW/S

More information

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal FTXB20-35C Rear side 770 Right side Standard location of holes in the wall 16 770 549 101 172 6 Left side Front panel fixing screws Including mounting plate 216 198 General Rating Nameplate 41.3 54.5 Hole

More information

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Keep looking you ll never find me. VRV IV heat pumps for indoor installation Keep looking you ll never find me i VRV IV heat pumps for indoor installation Invisible Keep looking you ll never find me Daikin VRV IV i-series offers you the most aesthetic and integrated air conditioning

More information

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS FOR MAXIMUM FLEXIBILITY AND CUSTOMISATION THE FREE MULTI HAS THE ANSWER Panasonic Free Multi systems bring

More information

Heating. Catalogue. Climate comfort. All Seasons. For end users. Heating. Air Conditioning. Applied Systems. Refrigeration

Heating. Catalogue. Climate comfort. All Seasons. For end users. Heating. Air Conditioning. Applied Systems. Refrigeration For end users Heating All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration Heating - Domestic hot water - Cooling top energy Daikin Altherma, efficient solutions

More information

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Today, the air is perfect. Perfect temperature. Perfect humidity. Perfectly clean and fresh,

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling»» Up to five indoor units» on one outdoor unit M u l t i m o d e l a p p l i c a t i o n»» Individual control» per room»» Combination» of different indoor models»» Inverter

More information

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps.   FTXS-G Full range A class energy label Air conditioners, heating & cooling for your home WALL MOUNTED UNIT air to air heat pumps www.daikin.eu FTXS-G FOR EVERY HOME, FOR EVERY ROOM unique features Full range

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling High COP, round flow cassette Seasonal efficiency, optimized for all seasons High COP cassette ensures top performance 360 air discharge Auto-cleaning cassette Even more

More information

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Elegant and stylish wall mounted unit providing high efficiency and comfort DSS Series single-zone

More information

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS FREE MULTI SYSTEM Z GAS FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit REFRIGERANT GAS FOR MAXIMUM FLEXIBILITY AND CUSTOMISATION THE FREE MULTI HAS THE ANSWER Panasonic Free Multi

More information

White paper: New Ecodesign rules and energy labelling for space and water heaters

White paper: New Ecodesign rules and energy labelling for space and water heaters White paper: New Ecodesign rules and energy labelling for space and water heaters White paper: New Ecodesign rules and energy labelling for space and water heaters The Ecodesign Regulation is one of the

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners & Cooling High COP, round flow cassette Seasonal efficiency, optimized for all seasons High COP cassette ensures top performance 360 air discharge Auto-cleaning cassette Even more comfort

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners & Cooling Concealed ceiling unit with inverter driven fan Seasonal efficiency, optimized for all seasons Discretely concealed in ceiling Reduced power consumption thanks to DC inverter

More information

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Remote control infrared ARC433B76 ARC433A8 ARC433B69 Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-

More information

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS 1.5-3 TON, 2-4 ZONE SYSTEMS UP TO 18.9 SEER / UP TO 12.5 HSPF / UP TO 12.7 EER VARIABLE-SPEED COMPRESSOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

More information

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer The natural fit, all-in-one Daikin Altherma monobloc heat pump for the installer Air-to-water technology Air-to-water technology Daikin Altherma monobloc Why choose Daikin Altherma monobloc? A monobloc

More information

Split Type Air Conditioners

Split Type Air Conditioners PCRMY1450 Split Type Air Conditioners DC Inverter Control 50 Hz Urusara 7 FTKJ Series FTKV Series FTKC Series Urusara 7 FTKJ Series Lineup of DC Inverter Air Conditio Daikin is the sole manufacturer to

More information

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS WALL-MOUNTED UNITS Up to 19 SEER / Up to 9.0 HSPF / Up to 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR 19 Series Discreet wall-mounted unit providing

More information

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS WALL-MOUNTED UNITS Up to 19 SEER / Up to 9.0 HSPF / Up to 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR 19 Series Discreet wall mounted unit providing

More information

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water High temperature heating system AIR TO WATER HEAT PUMPS Renovation - Heating - Domestic hot water Daikin Altherma Heat pumps The solution with an eye to the future Renovating your heating system and wanting

More information

Natural geothermal energy

Natural geothermal energy Natural geothermal energy ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient. L A ++ A Scale space heating

More information

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air conditioners, heating & cooling. for large spaces. air to air heat pumps.   FDQ-B Air conditioners, heating & cooling for large spaces CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDQ-B THE MOST ADVANCED CLIMATE CONTROL FOR LARGE SPACES The quality air conditoning of Daikin

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Replacement VRV Quick & quality replacement for R-22 and R-407C systems

Replacement VRV Quick & quality replacement for R-22 and R-407C systems Replacement VRV Quick & quality replacement for R-22 and R-407C systems 22 Indoor units VRV type indoor units Air curtain Biddle Air curtain for VRV (CYV) Ventilation Heat Reclaim ventilation (VAM/VKM)

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

Heating - Domestic hot water - Cooling. the intelligent way to comfort

Heating - Domestic hot water - Cooling. the intelligent way to comfort Heating - Domestic hot water - Cooling the intelligent way to comfort Efficiency & profitability WITH ENERGY PRICES SOARING People are becoming more and more aware of the cost of heating. Traditional heating

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling»» Up to five indoor units on one outdoor unit Multi model application»» Individual control per room»» Combination of different indoor models»» Inverter controlled www.daikin.eu

More information

The natural ombination

The natural ombination The natural ombination DAikin Altherma Hybrid heat pump 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e Energy label:» Up to class A Heat pump system Seasonal inverter technology Round flow 360 air discharge Fits flush» into a false ceiling

More information

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for shops,restaurants and offices Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing

More information

Wall mounted units. Total comfort at home

Wall mounted units. Total comfort at home Wall mounted units Total comfort at home Why choose Daikin? Daikin is a world leader in air conditioning and heating. So no matter what your needs, you will find the ideal solution in our wide range of

More information

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of Daikin s Policy and Comprehensive Actions on the Environmental Impact of Refrigerants Daikin provides homes, businesses and industries worldwide with cooling, heating and refrigeration solutions. We also

More information

HI-WALL SPLIT SYSTEMS

HI-WALL SPLIT SYSTEMS HI-WALL SPLIT SYSTEMS What you ll find inside: Technology Digital Inverter range Controllers Product specifications Effective air filtration Energy efficient Heating & cooling 1 Toshiba Air Conditioning.

More information

Up to SEER 26.1 Wall Mount Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump Up to SEER 26.1 Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s Quaternity system incorporates technological innovations that deliver features and benefits superior to traditional mini split systems.

More information

Daikin Altherma Low Temperature monobloc heat pump

Daikin Altherma Low Temperature monobloc heat pump Information for installers Daikin Altherma Low Temperature monobloc heat pump The natural choice Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Our broad experience,

More information

Simply renewable A ++ A +++ ROTEX air-to-water heat pump

Simply renewable A ++ A +++ ROTEX air-to-water heat pump Simply renewable The HPSU monobloc air-to-water heat pump for external installation offers comfortable heat in winter and gentle cooling in summer. System efficiency with Solar*: XL A ++ A +++ * ROTEX

More information

Information for end users. Wall mounted units. Total comfort at home

Information for end users. Wall mounted units. Total comfort at home Information for end users Wall mounted units Total comfort at home Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant innovation in comfort,

More information

for your home FLXS-B Flexi type unit air to air heat pumps

for your home FLXS-B Flexi type unit   air to air heat pumps Air conditioners, HEATING & COOLING for your home Flexi type unit air to air heat pumps www.daikin.eu FLXS-B TOP CLASS, MADE FOR A LONG FUTURE The importance of well-being and pleasure is increasing in

More information

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12. Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.2 EER INVERTER, VARIABLE-SPEED COMPRESSOR 15 Series Discreet wall mounted unit

More information

Elegant on the outside, smart in the inside.

Elegant on the outside, smart in the inside. Elegant on the outside, smart in the inside. You deserve a premium climate. Stylish is a combination of excellent design & intelligent technologies that delivers the ultimate climate solution for any interior.

More information

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact Europe s first light commercial cassette system using R-32 refrigerant Our mission The lowest environmental impact It s here The evolution of pure comfort and efficiency 2 Discover the next generation

More information

All-in-one comfort for residential applications. Product catalogue Heating

All-in-one comfort for residential applications. Product catalogue Heating All-in-one comfort for residential applications Product catalogue 2017 Heating Daikin world Supermarket Restaurant Technical Hotel Store & shop Bank Industry Home Office Sport & Leisure 2 The perfect working

More information

VRV IV S-series heat pump

VRV IV S-series heat pump VRV IV S-series heat pump The most compact VRV Most compact unit on the market 3mm high & kg Control systems Indoor units VRV type indoor units Residential type indoor units (such as Daikin Emura) Air

More information

Heating. Daikin Altherma Flex Type. Catalogue ALL SEASONS PERFECT C MFORT. Centralised 3-in-1 heating solution with the scope for individuality

Heating. Daikin Altherma Flex Type. Catalogue ALL SEASONS PERFECT C MFORT. Centralised 3-in-1 heating solution with the scope for individuality Daikin Altherma Flex Type Heating Centralised 3-in-1 heating solution with the scope for individuality Outdoor unit Indoor units One or more indoor and outdoor units H E AT I N G C ATA LO G U E 2 012 1

More information

The natural. hoice installer leaflet. DAikin Altherma low-temperature heat pump. Preliminary version

The natural. hoice installer leaflet. DAikin Altherma low-temperature heat pump. Preliminary version The natural hoice installer leaflet DAikin Altherma low-temperature heat pump Preliminary version Best seasonal efficiencies, providing the highest savings on running costs excellent COP ratings for incentive

More information

AIR CONDITIONERS, HEATING & COOLING for your home

AIR CONDITIONERS, HEATING & COOLING for your home AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides

More information

BENEFIT FROM LOWER FUEL COSTS.

BENEFIT FROM LOWER FUEL COSTS. TODAY, MORE AND MORE PEOPLE ARE MAKING A VERY CONSCIOUS CHOICE TO ENJOY THE COMFORT OF AIR CONDITIONING IN THEIR HOME. IT IS WIDELY RECOGNISED THAT BALANCED AIR CONDITIONING HAS A TANGIBLE EFFECT ON THE

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling W a l l M o u n t e d U n i t For high ambient temperatures up to 52 C 50 Hz Heat pump system Energy efficient Dehumification without a drop in temperature Same comfort

More information

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY PHOENIX PNX DCI AN AIRWELL GROUP COMPANY OUTDOOR UNIT GC 9-12-18 DCI OUTDOOR UNIT GC 21 DCI OUTDOOR UNIT GC 24 DCI RC4 (Actual consumption will depend on how the appliance is used and climate) Ful load

More information

LV Series. SEER 20+ Wall Mount Heat Pump

LV Series. SEER 20+ Wall Mount Heat Pump LV Series SEER 20+ Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s SEER 20+ single split systems feature wall mounted units with a sophisticated appearance and a flat panel design. Packed with high

More information

PCRAU0510. the. ultimate. heating and cooling guide

PCRAU0510. the. ultimate. heating and cooling guide PCRAU0510 the ultimate heating and cooling guide The ultimate heating and cooling guide Whether you know little or nothing about reverse cycle air conditioning, or you know quite a lot, you ll find this

More information

Hansol Hi Wall Inverter Air Conditioner

Hansol Hi Wall Inverter Air Conditioner Hansol Hi Wall Inverter Air Conditioner Find out more at www.greeonline.com Hansol Hi Wall Inverter Air Conditioner Why Choose a Gree Hansol Hi Wall Air Conditioner? Feature-rich with advanced components,

More information