"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8
|
|
- Delilah Darleen Chapman
- 5 years ago
- Views:
Transcription
1 Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD VALVES, STRAINERS, FILTERS, AND OTHER ASSOCIATED PRODUCTS. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS INJURY. 1. Webster and Hayward guarantees their products against defective material and workmanship only. Webster and Hayward assume no responsibility for damage or injuries resulting from improper installation, misapplication, or abuse of any product. 2. Webster and Hayward assume no responsibility for damage or injury resulting from chemical incompatibility between their products and the process fluids to which they are subjected. Compatibility charts provided in Webster and Hayward literature are based on ambient temperatures of 70 ºF and are for reference only. Customer should always test to determine application suitability. 3. Consult Webster and Hayward literature to determine operating pressure and temperature limitations before installing any Webster and/or Hayward product. Note that the maximum recommended fluid velocity through any Webster and Hayward product is eight feet per second. Higher flow rates can result in possible damage due to the water hammer effect. Also note that maximum operating pressure is dependent upon material selection as well as operating temperature. 4. Webster and Hayward products are designed primarily for use with non-compressible liquids. They should NEVER be used or tested with compressible fluids such as compressed air or nitrogen. 5. Systems should always be depressurized and drained prior to installing or maintaining Webster and Hayward products. 6. Temperature effect on piping systems should always be considered when the systems are initially designed. Piping systems must be designed and supported to prevent excess mechanical loading on Webster and Hayward equipment due to system misalignment, weight, shock, vibration, and the effects of thermal expansion and contraction. 7. Because PPL, PVC and CPVC plastic products become brittle below 40 ºF, Webster and Hayward recommends caution in their installation and use below this temperature. 8. Published operating torque requirements are based upon testing of new valves using clean water at 70 ºF. Valve torque is affected by many factors including fluid chemistry, viscosity, flow rate, and temperature. These should be considered when sizing electric or pneumatic actuators. Due to differential thermal expansion rates between metal and plastic, transmittal of pipe vibration, and pipe loading forces DIRECT INSTALLATION OF METAL PIPE INTO PLASTIC CONNECTIONS IS NOT RECOMMENDED. Wherever installation of plastic valves into metal piping systems is necessary, it is recommended that at least 10 pipe diameter in length of plastic pipe be installed upstream and downstream of the plastic valve to compensate for the factors mentioned above This manual should be furnished to the end user of this pump; its use will reduce service calls and chance of injury and will lengthen pump life. Page 1 of 10
2 S2 S4 S5 SS6 SS7 S8 SERIES CHEMICAL PUMPS To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! Webster Specialty Pumps: Are easy to install and operate. Have no bearings or shaft seals in the fluid being pumped. Can handle moderately abrasive liquids. Are designed to run dry without damage. Are virtually maintenance free. TABLE OF CONTENTS SAFETY INSTRUCTIONS...2 INSTALLATION OPERATION...5 MAINTENANCE Disassembly...6 Spacing... 7 Reassembly... 8 REPAIR PARTS LIST READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: DANGER warns about hazards that will cause serious personal injury, death or major property damage if ignored. WARNING warns about hazards that can cause serious personal injury, death or major property damage if ignored. CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which are important but not related to hazards. Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. Page 2 of 10
3 INSTALLATION Install pump inside tank (see Figure 1). Mount pump vertically with motor above highest liquid level in the tank. Be sure that highest liquid level in tank is below `Maximum Immersion' line located below bossed weep hole on pump column (Figure 1). Pump inlet opening must always be at least one foot above tank bottom. Inlet pipe (if used) must be at least as large as the pump inlet port. PLUMBING Fig 1 NOTICE: Thermoplastic pumps will not tolerate plumbing stress. To prevent distortion (cold flow) of pump body and possible damage to pump, be sure your plumbing is properly aligned and supported. Mount pump in tank so that pump inlet opening is at least one foot above tank bottom. Be sure that any foot valve or other hardware on inlet pipe will not stick closed or partially closed. Restricting flow can starve inlet, causing cavitation (which can damage pump). To be sure of priming on restart, install an inlet foot valve and discharge check valve or Be sure that fluid level covers discharge port after shutoff (see Fig. 1). When a foot valve is installed, manually prime pump for initial start-up. With both foot valve and discharge check installed, pump should not need priming for restart even if liquid level in tank falls below discharge port. NOTICE: To prevent liquid rising up the pump's vertical flange on shutoff, discharge check valve must be installed between one to three feet of the pump discharge port. Page 3 of 10
4 Hazardous voltage. Can shock, burn, or cause death. Ground pump before connecting to power supply. ELECTRICAL Ground motor before connecting to electrical power supply! Failure to ground motor can cause severe or fatal electrical shock hazard! Do not ground to a gas supply line! To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Motor wiring and supply voltage must match exactly to prevent poor performance and motor damage. Running the motor at the wrong voltage will void the warranty. ROTATION Motor shaft rotation is counterclockwise (CCW) viewed from suction end of pump. Running pump backwards may loosen impeller and will reduce performance. Single Phase Motors: Pre-wired for correct rotation and highest nameplate voltage. For lower voltage operation follow motor manufacturer's instructions inside wiring access cover or on motor. Three Phase Motors: Follow directions on motor nameplate to connect for desired voltage and rotation. See Table I for fusing and wiring data. TABLE 1 - MOTOR FUSING AND WIRING DATA PUMP MOTOR BRANCH FUSE MAX LOAD VOLTAGE/ WIRE SIZE (AWG) DIST. IN FEET (SERVICE TO MOTOR) MODEL NO. H.P. RATING (Amps) (Amps) HZ/PHASE 0-100' ' ' S / / /230/60/50/ / / /460/60/50/ S / / /230/60/50/ / / /460/60/50/ S / / /230/60/50/ / /460/60/50/ SS / / /230/60/50/ / / /460/60/50/ SS / /230/60/50/ / / /460/60/50/ S / / /230/60/50/ / / /460/60/50/ Page 4 of 10
5 OPERATION Webster pumps will handle temperatures from 20º F. to +260 ºF. and a wide range of chemicals (depending on pump materials; see catalog data). NOTICE: Liquid within impeller will cause heavy side loading and may cause motor bearing failure and pump damage. To prevent liquid from rising high enough to fill impeller: 1. Use a liquid level control on sump installations. 2. Set liquid level control to start pump when sump liquid level is between discharge port centerline and `Maximum Immersion' line on pump flange. 3. Pump should shut off before liquid level has reached bottom of pump inlet. NOTICE: Webster pumps are designed to allow dry running. However, do not run pump partially dry; that is, 1. Do not operate pump with impeller only partially submerged and 2. Do not operate pump with impeller alternately submerged and dry. Operating under these conditions will put shock loads on the pump which can cause early motor bearing or pump failure. Fig 2 CAUTION: If pump runs dry, NEVER allow pumping chamber to refill while pump is running! To avoid shock load, stop pump while liquid level rises into pumping chamber. START-UP 1. Manually prime pump before starting for the first time. 2. Close pump discharge. 3. Start pump. 4. Open discharge to desired flow rate. 5. With both foot valve and discharge check installed and operating correctly, pump will not need priming for restart even if liquid level in tank drops below discharge port. (Figure 2) Page 5 of 10
6 MAINTENANCE To avoid danger of injury from electrical shock or from motor unexpectedly starting, disconnect power to motor before working on pump. Disassembly: 1. Use a screwdriver to pry retaining ring (Key No. 9, Figure 3) toward suction port and out of its groove. 2. Pull end cover (Key No. 7) out of pump body (Key No. 5). Move end cover from side to side while pulling to loosen it. Do not remove end cover " 0 " Ring (Key No.8) unless you are replacing it. 3. Remove nosepiece (Key No. 6D) by holding motor shaft with a 1/8" Allen wrench inserted into shaft set screw (Key No. 3) through access hole closest to the motor and unscrewing nosepiece counterclockwise. 4. Unscrew impeller (Key No. 6 - counterclockwise) by again holding motor shaft with a 1/8" Allen wrench inserted into shaft set screw (Key No. 3) through access hole from shaft and lift out of pump body. 5. Remove four pump bolts and washers (KEY Nos. 10 and 11). Lift body (Key 5) off motor. 6. Loosen two shaft set screws (Key No. 3). Pry pump shaft off of motor with two screwdrivers. 7. Do not remove fume seal (Key No. 4) unless it needs replacement. 8. For pump motor maintenance, consult factory. NOTICE: Disassembly of motor will void motor manufacturer's warranty. NOTICE: To prevent impeller / pump body interference and damage to pump, pump shaft must be spaced. Fig 3 Page 6 of 10
7 Spacing: 1. Start shaft set screws (Key No. 1, Figure 4) in screw holes on pump shaft. Slide pump shaft onto motor shaft with screws aligned with flat or keyway. 2. Place spacing washers on motor face. (Key No. 2, Figure 4) Shim CPVC and polypropylene models to.060 ; shim PVDF models to.100 clearance. 3. Place pump body (Key No. 4, Figure 5) on motor face and install two body bolts on opposite sides of flange (180º apart). Hand tighten only. (Key No. 3, Figure 5) 4. Make sure that the pump body is mounted squarely on motor. 5. Hold motor shaft with 1/8" Allen wrench inserted through access hole into shaft set screw. NOTICE: Do not tighten set screw at this time. Screw impeller onto shaft (turn clockwise) until it bottoms out on shaft shoulder (not on pump body flange plate. (Key No. 6, Figure 6) 6. After impeller stops, press down on it until it hits baffle in pump body (Key No. 7, Figure 7). Tighten one set screw (Key No. 8, Figure 7) 7. Continuing to hold shaft, unscrew impeller (counterclockwise) and remove. 8. Remove pump body, bolts and spacing washers or shims. 9. Tighten remaining set screw. Torque both the set screws to 70 inch-lbs torque. Page 7 of 10
8 Spacing and Reassembly: Key 6A Key 2 Key 5 FIGURE 8 1. Slide " 0 " Ring (Key No. 6A, Figure 8) onto shaft (Key No. 2, Figure 8) to within 1/2" of coupling. Leave it far enough away from coupling so that impeller sleeve will push it into final position on shaft. (During operation, " 0 " Ring provides a back-up to liquid level control to help keep liquid out of the impeller.) 2. Place pump body (Key No. 5) on motor without shims or spacers. Bolt to motor. 3. Hold pump shaft (Key No. 2) with Allen wrench inserted into shaft set screw (Key No. 3) through access hole. Screw impeller (Key No. 6B) onto shaft (turn clockwise). 4. To lubricate nosepiece " 0 " Ring (Key No. 6C) and hold it in place in nosepiece groove, apply a small amount of compatible lubricant to " 0 " Ring; mount " 0 " Ring into nosepiece groove (Key No. 6D). 5. Hold impeller stationary. Using largest screwdriver that will fit nosepiece drive slot, install nosepiece and " 0 " Ring (Key Nos. 6C and 6D) Torque lock screw to 40 inch-lbs. Impeller should turn freely by hand. NOTICE: A small screwdriver may split nose piece. FIGURE 9 NOTICE: To properly seal impeller body and maintain locking tension, nose piece should seat against impeller at 40 inch-lbs torque. If not, remove nose piece and find cause. Do not operate pump until problem has been found and corrected; to do so could allow liquid into impeller body, throwing impeller out of balance and possibly damaging pump. 6. Inspect pump body " 0 " Ring (Key No. 8) for cuts, nicks, and abrasion. If worn or damaged, replace it. Stretch " 0 " Ring into groove in pump body without rolling or twisting it. Lubricant on " 0 " Ring will make installation easier. 7. Replace end cover (Key No. 7) in pump body, making sure that it is inserted past retaining ring groove. Seat end cover with a rubber mallet. 8. Replace retaining ring (Key No. 9) in groove in pump body. Make sure it is completely seated. 9. Check clearance A with bent wire feeler gauge (see Figure 9 Table III) Page 8 of 10
9 WEBSTER Seal-less Immersible Pump S2, S4, S5 SERIES MODEL NUMBER (CPVC) S2 S4 S5 1S2GX0009 1S2GX0003 1S2GX0008 1/3 Hp 1ph 1S4GX0009 1S4GX0003 1S4GX0008 3/4 HP 1ph 1S5GX0009 1S5GX0003 1S5GX HP 1ph Key No. Part Description 1S2HX0009 1S2HX0003 1S2HX0008 1/3 HP 3ph 1S2HX0009 1S2HX0003 1S2HX0008 3/4 HP 3ph 1S2HX0009 1S2HX0003 1S2HX HP 3ph 1 Motor 115/230V/60/50Hz/1 Ph Motor /460V/60/50Hz/3Ph Shaft (Incl. 2 No. 3) Set Screw, Allen Hd.(2 Req.) U30-893SS U30-893SS U30-893SS 4 Lip Seal (Fume Barrier) U U U Body Assembly Impeller Kit (Incl. Key #6A, 6B, 6C, 6D) N/A PK912 PK1089 6A Impeller *** B Nosepiece *** V C Shaft "0" Ring ** V6-314 V D Impeller "0" Ring ** V6-113 V End Cover " 0 " Ring (End Cover) V6-330 V6-335 V Retainer Screw, Hex Hd. (4 Req.) U30-74SS U30-74SS U30-74SS 11 Washer (4 Req.) U43-62SS U43-62SS U43-62SS Pump Hd. Ass'y*** 4660V 5920V 5080V Not illustrated. ** Not available separately. Order Impeller Kit. *** Includes all parts except motor. NOTE ON PART NUMBERS: For CPVC parts: use listed part number, no suffix added. For PVDF parts: use listed part number plus -2 suffix; for example For Polypropylene parts: use listed part number plus - 3 suffix: for example Page 9 of 10
10 WEBSTER Seal-less Immersible Pump SS6, SS7, S8 SERIES SS6 SS7 S8 1SS6GX009 1SS7GX009 1S8GX0009 1SS6GX003 1SS7GX003 1S8GX0003 1SS6GX008 1SS7GX008 1S8GX0008 3/4 HP 1 PH 1 HP 1PH 1 1/2 1PH 1SS6HX009 1SS7HX009 1S8HX0009 1SS6HX003 1SS7HX003 1S8HX0003 1SS6HX008 1SS7HX008 1S8HX0008 Key Part 3/4 HP 3 PH 1 HP 3 PH 1 1/2 3 PH No. Description 1 Motor 115/230V/60/50Hz/1 Ph Motor 208/230/460V/60/50Hz/3Ph Shaft (Incl. 2 No. 3) Set Screw, Allen Hd.(2 Req.) U30-893/SS U30-893/SS U30-893/SS 4 Lip Seal (Fume Barrier) U U U Body Assembly Impeller Kit (Incl. Key #6A, 6B, 6C, 6D) PK1078F PK1078G PK1078 6A Shaft "0" Ring*** V6-314 V6-314 V B Impeller *** 1078F 1078G C Impeller "0" Ring*** V6-113 V6-113 V D Nosepeice*** End Cover***t " 0 " Ring (End Cover) V6-341 V6-341 V Retainer Screw, Hex Hd. (4 Req.) U30-74SS U30-74SS U30-74SS 11 Spacer Washer (4 Req.) U43-62SS U43-62SS U43-62SS Pump Hd. Ass'y*** 6080V 6090V 4650V Not illustrated. ** Entire liquid end; includes all parts except Key No. 1, Motor. *** Not available separately. Order Impeller Kit. NOTE ON PART NUMBERS: For CPVC parts: use listed part number, no suffix added. For PVDF parts: use listed part number plus -2 suffix; for example For Polypropylene parts: use listed part number plus -3 suffix: for example Page 10 of 10
"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16
Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD VALVES,
More informationMECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationLC Series - Light Commercial Pump Station Installation and Operation Manual
LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump
More informationMECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSpecifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95
Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B-95 394A-95 thru 394D-95, 399A-95 Please read and save this Repair Parts Manual. Read this manual and the General Operating
More information568X, 587X, 588X Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationAC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationSeries PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC
Series PX Installation & Maintenance Models: PX-3 PX-5 PX-7 /2-HF PX-0-HF PX-5-HF Materials: A - CPVC Introduction Penguin Pumps are designed to handle a large range of chemicals without difficulty. Completely
More information489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSeries P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF
Series P Installation & Maintenance Models: P-/5 P-/6 P-/4 P-/ P-/-HP P-3/4 P-3/4HP P- P- / P- P-3 P-5 P-7 / Materials: A - CPVC B - Polypropylene C - PVDF Introduction Penguin Pumps are designed to handle
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationKC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions
KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More informationKC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions
KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump
More informationVertical Inline Models
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationWarranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5
5 . Manual Contents Warranty Details page 2 Pump Description & Technical page 3 Specifications Transportation, Storage & Installation page 4 Pump Maintenance page 5 Wet end Dismantling page 6 Wet end Assembly
More informationsta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:
OWNER S MANUAL Centrifugal Pumps sta-rite C and CC Series 2791 0397 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-888-782-7483 293 WRIGHT STREET, DELAVAN,
More informationREF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.
4.4 SUPPLY PUMPAK ASSEMBLY NOTE: This section applies only to systems, which include a supply pumpak. Only the H6, XA, and XC series systems contain a supply pumpak. If your system is a single zone, H6
More informationCONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS
CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-71 SinkSpa JETTED SINK Model LJD1306L JOB AID Part No. 8178201 FORWARD This Whirlpool Job Aid, SinkSpa Jetted Sink, (Part No. 8178201), provides the
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model
Section: MOYNO 500 PUMPS Page: 1 of 4 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and 36752 Model DESIGN FEATURES Housing: Cast iron/316 SS
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationThis label warns for risk of electrical shock when failing to observe.
MANUAL horizontal centrifugal pumps MB series ic drive SB series mechanical seal 1. Introduction 2. Safety precautions 3. Receipt 4. Installation / Operation and Maintenance 4.1 Installation 4.2 Operation
More informationIPT Series 2P5X, 2S5X, 2S5XC & 3S5X Pumps Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSeries P. Installation & Maintenance. Introduction. Models: P-1/15 P-1/6 P-1/4 P-1/2 P-1/2-HP P-3/4 P-3/4HP P-1 P-1 1/2 P-2 P-3 P-5 P-7 1/2
Series P Installation & Maintenance Models: P-1/15 P-1/6 P-1/4 P-1/2 P-1/2-HP P-3/4 P-3/4HP P-1 P-1 1/2 P-2 P-3 P-5 P-7 1/2 Materials: A - CPVC B - Polypropylene C - PVDF Introduction Penguin Pumps are
More information316 Stainless Steel Close- Coupled Self-Priming Flexible Impeller Pumps
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½
SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½ OPERATION AND SERVICE GUIDE O-820_R FEBRUARY 2013 Refer to Bulletin P-201 and Parts Lists: P-7200, P-7250. SAFETY PRECAUTIONS BEFORE STARTING PUMP 1. Read
More informationD1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications
2HP Centrifugal Grinder Pump Installation & Service Manual with Parts List D1C20-21 Grinder Pump for Residential and Pressure Sewer Applications NOTE! To the installer: Please make sure you provide this
More informationTURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual
TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO
More information1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide
1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct
More informationPenguin. Series P. Vertical Pump
Series P Flows from 9 to 7 Pressure to 66 Ft. Penguin Vertical Pump Features: Choice of CPVC, PVDF, or Polypropylene Runs Dry Without Damage Self-Priming When Immersed No Metal Contact Chemical Resistant
More information50 HZ. MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP
50 HZ. MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R S M A N U A L INSTALLATION, OPERATION & PARTS 5P6R Series MODELS HP 1 Phase 3 Phase 3/4 5P6R6D-209 5P6R6D3-209 1 5P6R6E-210 5P6R6E3-210 1-1/2
More informationGP22/32 SERIES Sealed Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions
GP22/32 SERIES Sealed Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. PUMPS WITH MOTOR No assembly required. Simply
More informationSSHM-2. Call Self-Priming Horizontal Multistage Pump. For further operating, installation, or maintenance assistance:
293 Wright St., Delavan WI 53115 OWNER S MANUAL Self-Priming Horizontal Multistage Pump SSHM-2 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-888-237-5353
More informationINSTRUCTION AND REPAIR MANUAL
SECTION 6 ITEM 390 DATED JANUARY 2003 SUPERSEDES SECTION 6 ITEM 390 DATED OCTOBER 2000 INSTRUCTION AND REPAIR MANUAL SERIES 390 6 The 390 Series is a superior commercial Multi-Stage Vertical In-Line Centrifugal
More informationOWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST
OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST SCX1740 SERIES CENTRIFUGAL PUMP High Head - Noryl Impellers MODELS Model ODP MOTORS TEFC MOTORS HP Number 115/230/60/1 20-230/460/60/3
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationSHURFLO 316 STAINLESS STEEL CLOSE-COUPLED SELF-PRIMING FLEXIBLE IMPELLER PUMPS OPERATION INSTRUCTIONS, PERFORMANCE, SPECIFICATIONS & PARTS MANUAL
SHURFLO 316 STAINLESS STEEL CLOSE-COUPLED SELF-PRIMING FLEXIBLE IMPELLER PUMPS OPERATION INSTRUCTIONS, PERFORMANCE, SPECIFICATIONS & PARTS MANUAL MODELS MRS9000, MRS9001, MRS9900, MRS9901, MRS15000, MRS15001
More informationOWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS
OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS IL00 Figure - CJ0, EL0 Series IL0 Figure - CJ0, EL0 Series Drain Plug READ THESE INSTRUCTIONS CAREFULLY Read these installation
More informationHORIZONTAL MULTISTAGE CENTRIFUGAL PUMP
HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug
More informationMG200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential and Pressure Sewer Applications.
MG200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL 2 HP Grinder Pump for Residential and Pressure Sewer Applications. NOTE! To the installer: Please make sure you provide this manual to the owner
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01900 Revision 2 Printed in Canada 1.1 INTRODUCTION Thank you
More informationSMF PUMP OWNER S MANUAL
SMF PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning
More informationDESCRIPTION IMPELLER INSPECTION MAINTENANCE POWER CORD REPLACEMENT IMPELLER REPLACEMENT MECHANICAL SEAL REPLACEMENT IMPELLER INSPECTION /REPLACEMENT
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationImpeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5
GRUNDFOS CR Series Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 5 Grundfos Pumps Corporation 17100 W. 118th Terrace Olathe, Kansas 66062 Telephone: 91.227.00 Fax: 91.227.500 www.grundfos.com
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01524 Revision 15 Printed in Canada 1.1 INTRODUCTION Thank
More informationMODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors
MODEL SK2750 COMPRESSOR SERVICE KIT For use on 2750 Series Compressors WARNING: Unplug the compressor before beginning disassembly. CAUTION: Improper assembly or use of damaged parts may lead to premature
More informationCHAMPION PUMP OWNER S MANUAL
CHAMPION PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all warning notices and instructions
More informationDAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz
DAGNY LK Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 110V~60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any
More informationAC6/6H & AC8/8H Horizontal Metric Models
AC6/6H & AC8/8H Horizontal Metric Models ASSEMBLY, INSTALLATION AND OPERATION MANUAL Part No. 108203 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully
More information489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationMODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32
MODEL 77001616 COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32 WARNING: Unplug the compressor before beginning disassembly. CAUTION: Improper assembly or use
More informationDESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationThe Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.
The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts you to potential hazards or unsafe practices which,
More informationSHURflo Bronze Pedestal Self-Priming Flexible Impeller Pumps
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H
SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HP Phase Medium Head High Head 3 1 BMLS 300 M BMLS 300 H 3 3 BMLS 300 M3 BMLS 300 H3 5 1 BMLS 500 M BMLS
More informationAudi-Larm Audible Alarm
Audi-Larm Audible Alarm MAINTENANCE AND REPAIR TAL 1706 (L) Rev. 7 MSA 2017 Prnt. Spec. 10000005389(I) Mat. 10093084 Doc. 10093084 REPLACEMENT KITS AND PARTS LIST TAL 1706 (L) Rev. 7-10093084 2 Exploded
More informationSPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP
AQUATIC ECO-SYSTEMS SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE
More informationMODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors
MODEL SK2660 COMPRESSOR SERVICE KIT For use on 2660 and 2680 Model Compressors WARNING: Unplug the compressor before beginning disassembly. CAUTION: Improper assembly or use of damaged parts may lead to
More informationBSP4/BSPD4, BSP6/BSPD6 & BSPD8 Self-Priming Sewage and Trash Pumps. Installation and Service Manual
BSP4/BSPD4, BSP6/BSPD6 & BSPD8 Self-Priming Sewage and Trash Pumps Installation and Service Manual 056255121 GENERAL INFORMATION The Berkeley self-priming centrifugal pump has a semiopen impeller and suction
More informationOWNERS GUIDE TO INSTALLATION AND OPERATION
OWNERS GUIDE TO INSTALLATION AND OPERATION SPM SERIES HIGH POWER CENTRIFUGALS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump. Be sure to check
More informationMODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors
MODEL SK2660 COMPRESSOR SERVICE KIT For use on 2660 and 2680 Model Compressors WARNING: Unplug the compressor before beginning disassembly. CAUTION: Improper assembly or use of damaged parts may lead to
More informationCPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV
Series HV Flows to 132 GPM Pressure to 81 Ft. TDH Model HV-1 1/2DV CPVC Horizontal Centrifugal Pump Features: True Volute Design High Efficiency Energy Saving Higher Flow vs. Pressure No Metal Contact
More informationQUICK PRIME INSTALLATION AND SERVICE MANUAL
QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #
More informationInstallation Instructions Part No , Part No Part No
Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11
More information36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)
36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-607(B) Series FS7-4 Industrial Liquid Flow Switch (specified models only) Series FS7-4 OPERATION This control is an independently mounted water
More informationSERIES ABG SWIMMING POOL PUMP
SERIES ABG SWIMMING POOL PUMP O W N E R S M A N U A L DO NOT OVER TIGHTEN INSTALLATION, OPERATION & PARTS This manual should be furnished to the end user of this pump; its use will reduce service calls
More informationModels Series Series
Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload
More information! WARNING. Before using product, read and understand instructions.
Installation & Maintenance Instructions MM-60C) Series FS4-3 General Purpose Liquid Flow Switch specified models only) Now with Stainless Steel Paddles OPERATION This control is an independently mounted
More informationFOOD WASTE DISPOSER INSTALLATION AND USE MANUAL
FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL English only (Australia and New Zealand) 1a 1 1b 1 1c 11 3 1 17 3 13 4 1 7 14 1 0 1 7174 Rev C www.insinkerator.com 01 InSinkErator, a business unit of Emerson
More informationElite Primer Baldor Series External Pond Pump
Elite Primer Baldor Series External Pond Pump ( 5250PPB21, 6440PPB23, 7550PPB26, 9600PPB28) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS
More informationSTAINLESS STEEL UNITS
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationHEATING AND AIR CONDITIONING
WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT
More information! WARNING. Before using product, read and understand instructions.
Installation & Maintenance Instructions MM-616 Series FS-5 General Purpose Liquid Flow Switch specified models only) Series FS-5 OPERATION This control is an independently mounted water flow sensing device
More informationQUICK PRIME INSTALLATION AND SERVICE MANUAL
QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #
More informationModels Series Series
Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload
More informationSuperKlean Washdown Products
DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot
More informationSuperFlo High Performance Pump
SuperFlo High Performance Pump Installation and User's Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Customer Service If you have questions about ordering
More informationQUIETFLO OWNER S MANUAL
QUIETFLO OWNER S MANUAL INSTALLATION, OPERATION & PARTS To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completley. CAUTION - We highly recommend a qualified
More informationPanel Fan Series Operators Manual (Galvanized and Polymer)
Panel Fan Series Operators Manual (Galvanized and Polymer) Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble,
More informationECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL
ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING: Before installing this product, read and follow all
More informationInstallation Instructions
Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 1540/1541 7084 433-00 Important Please read and follow these instructions These instructions contain Danger, Warning and Caution
More informationPUMP OWNERS MANUAL. ProVac 3 PUMP
Performance by Design PUMP OWNERS MANUAL ProVac 3 PUMP Westmoor, Ltd. P.O. Box 99, 906 West Hamilton Avenue Sherrill, New York 346 Phone: 800-367-0972 Fax: 35-363-093 E-mail pumps@westmoorltd.com INITIAL
More informationOPERATION & MAINTENANCE MANUAL FOR VIL VERTICAL INLINE PUMPS TYPES CS, CC, RC, AND DS
OPERATION & MAINTENANCE MANUAL FOR VIL VERTICAL INLINE PUMPS TYPES CS, CC, RC, AND DS PATTERSON PUMP COMPANY A GORMAN-RUPP COMPANY PO Box 790 2129 Ayersville Road Toccoa, Georgia 30577 Telephone: 706-886-2101
More informationBELT DRIVEN STATIONARY AGITATOR
BELT DRIVEN STATIONARY AGITATOR INSTRUCTION MANUAL www.usfarmsystems.com 2955 S. K Street Tulare, CA. 93274 (559)685-0340 (800)811-9462 Fax (559)685-9160 Revision Date 9/7/2017 TABLE OF CONTENTS How to
More informationIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.
Eagle Pump Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. INSTALLATION... 2 SECTION II. OPERATION & MAINTENANCE... 2 SECTION
More informationPanel Fan Series Operators Manual (Galvanized and Polymer)
Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before
More informationC-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz
C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company
More informationHT650 TM FAN DRIVE SERVICE INSTRUCTIONS
HT650 TM FAN DRIVE SERVICE INSTRUCTIONS When unpacking your product, remove all components and inspect them to ensure that no damage occurred during shipping. If any components are missing or damaged,
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationBliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES
6.0 Bliss Box Former 1.0 INTRODUCTION Table 6-1 provides a logical sequence of tests that are designed to isolate problems with the Bliss Box Former machines. This table includes a list of probable causes
More informationSWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL
SWP (Models SWP08 through SWP20) OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationHALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps
Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this
More informationFES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS
FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.
More informationClean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
Clean & Clear Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS SECTION I. SECTION II. SECTION III. SECTION IV. SECTION V. SECTION
More informationInstallation, Operation, and Maintenance Manual
READ AND SAVE THESE INSTRUCTIONS PART # 538 Model BCF Belt Drive Centrifugal Cabinet Fans Installation, Operation, and Maintenance Manual Please read and save these instructions for future reference. Read
More information