plumbing PINPOINTING PRESSURE PROBLEMS
|
|
- Matthew Harmon
- 5 years ago
- Views:
Transcription
1 plumbing BY STEVE GOLDIE PINPOINTING PRESSURE PROBLEMS Some of the most frequent complaints heard by plumbing contractors involve water pressure issues. It is a familiar scenario: you are all lathered up enjoying that nice hot shower when someone decides it is time to turn on the dishwasher, or maybe the washing machine. Suddenly that nice steady soothing stream of water becomes an irritating trickle, turning a relaxing shower into a potentially ugly domestic incident. Is this just one of those universal irritants that our customers need to learn to live with, or can something be done? The answer depends on what the source of the problem really is: poor pressure or insufficient flow. A typical residential plumbing system is designed to operate at between 40 and 70 pounds per square inch (psi) of pressure. In a municipally delivered system, water pressure is maintained through a series of pumping stations, elevated water reservoirs and water towers. Gravity provides the necessary pressure at a rate of one psi for every 28 inches of elevation (water column), resulting in just over 64 psi at the bottom of a 150-foot water tower. Water pressure at any individual home or business is determined by its elevation relative to the elevation of the water tower or reservoir serving it. For residences on private wells, water pressure is maintained via the well pump, usually in conjunction with a pre-charged pressure tank. IDENTIFYING THE REAL CULPRIT Verifying the static pressure (pressure when all taps are turned off) is as simple as attaching a pressure gauge at any The answer depends on what the source of the problem really is: poor pressure or insufficient flow point in the system. Gauges that attach to a hose connection are perfectly suited to this application. Most well systems should have gauges already installed making verifying the pressure even simpler. If the static pressure is lower than 40 psi then the problem is indeed a lowpressure problem. This would normally occur in higher areas, perhaps a house built up on a ridge, makes for nice views, but sometimes at the cost of adequate water pressure. If moving is not an acceptable option, then the remedy is to install a booster pump package. Booster pumps are available from many manufacturers in various sizes, and if a simple boost in pressure is all that is needed, your local wholesaler should be able to help find one that is right for your application. If a simple boost in pressure was CONTINUED ON PAGE 28 Photo Moen 26 HPAC 80 years MAY/JUNE 2006
2 Handle it right, right out of the gate. The buzzer sounds, the gates open and your project is off. You need a clean break at the start and a good grip on those powerful fast-track schedules before they run out of control. Victaulic powers any compressed schedule with our complete mechanical pipe joining systems that install up to three times faster than alternative methods. Value-added services like project preplanning and job-site product management increase efficiency on the job to make sure you ride out the race in record time. From day one, Victaulic people, products and technology surround your project and provide a much-needed release valve. Labour costs shrink. Hot work and fire watch delays disappear, as do the odds of liquidated damages. For over 80 years, only one company has been riding the reins of reduced schedules across the globe. Victaulic. COMPLETE PIPE JOINING SOLUTIONS WHEN SCHEDULE MATTERS Circle #16
3 plumbing CONTINUED FROM PAGE 26 always the remedy, restoring domestic bliss in the home would be a simple matter: install a properly sized pump, adjust the pressure switch and everyone is singing in the shower. Unfortunately, more often than not pressure problems are actually a result of inadequate distribution piping. Let s go back to our pressure gauge, when we check the pressure with all the If the incoming water service is the culprit, the most obvious solution is to upgrade to a newer, larger line. This requires trenching or torpedoing a new line in from the municipal service. If this option is not possible or desired, a pressure pump system can be installed, very similar to those installed on private well systems with a reservoir tank taking the place of the well or lake. pull any more water than the service can already provide. The reservoir tank provides a ready supply of water for the pump to pull from, enabling the requisite boost in pressure and flow. Without the reservoir tank the homeowner is paying good money for a pressure pump system only to have the same problem that existed before the system was installed. Without the reservoir tank the homeowner is paying good money for a pressure pump system only to have the same problem that existed before the system was installed. taps turned off everything looks good. Now have a look when one or two taps or fixtures are turned on. If the pressure drops dramatically, then the system piping is not able to allow sufficient flow to maintain adequate pressure. The water service coming into the building may be undersized, or in an older building scale or corrosion may have built up, choking off the flow. The distribution piping within the building may also be undersized or obstructed. Providing the correct solution requires identifying where the deficiencies are located. CONSIDER THE FIXTURES The final part of the distribution system also has to be sized and piped sufficiently to allow enough flow throughout the house when more than one fixture is turned on. I recently looked at a nearly finished 3,500 sq. ft. custom home with five bathrooms that a friend had purchased. The master bath has a Private well and pump systems include shower fixture with multiple heads and a well (the water source), piping from a large volume rainfall head. These the well to the building, a water pump, multi-head shower systems are very and a water pressure tank to which popular these days, but in order to building water supply plumbing is connected. When water is turned on at a 1/2 pipe just won t cut it. work properly they need lots of flow, fixture in the building, compressed air Closer scrutiny revealed that not in the water pressure tank pushes water only was the master shower fixture out into the building water supply piping and thus to its plumbing fixtures. had also been piped in 1/2 copper. piped in 1/2 copper, the entire house The reservoir tank is not the same The nice new one-inch service had thing as the pressure tank. Water is been reduced immediately to 1/2 copper to serve the entire house. To make pumped into the pressure tank, from the reservoir tank. Simply adding a pump to an inadequate service will not CONTINUED ON PAGE 30 The new face of... New bold look! Available on all Cable Drive configurations Ergonomically friendly All special finishes TM OAKVILLE STAMPING & BENDING LTD HPAC 80 years MAY/JUNE 2006 Circle #17
4 Focus on Performance 5 criteria for specifying the right water tempering and recirculation system Live and learn - your system is only as reliable as the sum of its parts. At the heart of every system is the tempering valve, so make sure you don t take shortcuts here. Preassembled and factory tested, PowerStation insures your facility's tempering and recirculation is installed exactly as specified. No headaches, no complaints, no worries. Here's what to look for... S i n g l e - Valve Tempering The heart of your system ASSE 1017 Listed, single-valve, p a r a f fin-based tempering valves regulate water temperature e f fic i e n t l y, while reducing system size, components and cost. Efficient Pump and Return Exceptional low flow valve performance enables smaller and more efficient pump selection and return line size, thus lowering operational and maintenance costs. Automatic Balancing The alternative to manual ball valve circuit setting, the thermostatic balancing valve maintains system balance by accurately, automatically and proportionally sending water to the boiler as needed. B y p a s s/ Test Loop The test loop makes simple work of system setup, and maintenance testing thereafter is quick and easy. No need to send unregulated hot water to the building during set-up. Pressure Temperature Gauges Large, easy-to-read gauge shows both pressure and temperature, making it easy to diagnose your system. Inside Sales: Circle #64
5 plumbing CONTINUED FROM PAGE 28 Large volume shower systems need a lot of flow. matters worse, the house was 95 per cent dry walled and a few days away from getting painted. The builder refused to address the issue but in the end my friend was able to negotiate sending an independent plumbing contractor in to fix the problem. Many contractors do great work and properly size systems, but the situation described above is an all too common example of the kind of thing that goes on. Dealing with pressure and flow problems in an older house is understandable, but having to live with it in a brand new home is never acceptable. Main supply lines and risers, both hot and cold should be 3/4 minimum, with 1/2 lines only used as feeders to individual fixtures. A 3/4 pipe has almost 50 per cent more circumference and nearly 132 per cent greater cross-sectional area than a 1/2 pipe. This means much more water, less resistance and therefore much more pressure and flow at the fixtures. The difference in cost between doing it right or not is but a proverbial drop in a bucket and homeowners will not hesitate to pay if they understand the benefits. It is a small price to pay for the ability to shower without worrying about who is flushing what. Steve Goldie worked as a plumbing and heating contractor for almost 20 years before joining Noble Trade as manager of the heating department. In his current position Goldie focuses on product specification and system design solutions. He can be reached at stevegoldie@nobletrade.ca. RATE THE ARTICLE! Will this information be useful? Please circle the appropriate number on the Reader Postcard. Thank you. VERY USEFUL USEFUL NOT USEFUL Photo Kohler Co. Kindred Commercial Manufacturer of Stainless Steel sinks for Institutional, Commercial and Industrial building applications. Franke Kindred Canada Limited Tel Fax Circle #55 30 HPAC 80 years MAY/JUNE 2006
6 APOLLO 77C The solid value of Apollo for today s value-conscious contractor Here s something today s contractors have been asking for: an economical full-port version of the classic American-made Apollo ball valve. Made in the Carolinas, our new 77C Series is priced competitively with the imports, but offers so much more quality and value. Solid Ball, Solid Performance Some valve manufacturers use hollow balls in their full port valves. Hollow balls create turbulence that restricts flow and causes unwanted pressure drops. Apollo s solid machined ball gives you straight-through flow and real full-port performance. Get solid full-port performance at an affordable price with the American-made Apollo 77C. See your Apollo distributor or contact Conbraco Industries, Canada today. COAP Phone: (905) Fax: (905) Circle #6
GORD COOKE. issues associated with humidification and dehumidification systems. In this article, humidification
humidification BY GORD COOKE OPTIONS IN STEAM Since the thermal comfort of occupants in buildings is dependent on the amount of moisture in the air, HVAC contractors need to understand proper sizing, installation
More informationA: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance.
A: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance. Q: How likely am I to run into this imbalance problem? A: It all
More informationSo visit (Dealer Name), and see the difference a Massey Ferguson lawn care specialist makes.
TITLE: 2500 Series ANNCR: You ve heard of sports enthusiasts and fishing enthusiasts, but how about lawn enthusiasts? Well, there are lots of you out there who just love having a beautiful lawn. And lawn
More informationWater Heater. Promising endless. Installing an On-Demand
Installing an On-Demand Water Heater Pluses include endless hot water and a compact design, but the installation means a lot of pipes in a small space by Tom Cardillo Promising endless hot water and taking
More informationINSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always
More informationhydronics WHAT S WRONG WITH THIS SCHEMATIC?
BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way
More informationLet s Go Back to the Future!
Let s Go Back to the Future! Welcome to the 2 nd Hot Water Forum Larry Weingarten and Gary Klein The Water-Energy-Greenhouse Gas Connection A Birdseye View Near Raleigh and Durham, North Carolina December
More informationHow Much Does a Bathroom Remodel Cost?
How Much Does a Bathroom Remodel Cost? We get asked this question quite often. It's a good question because bathroom remodeling is something most people don t do very often so they don t know what the
More informationRoseheart Water Pressure As Of: June 28, 2017
Roseheart Water Pressure As Of: June 28, 2017 Potential Problems Within Roseheart Recently, there have been a couple of homes in Roseheart that have experienced damage due to spikes in water pressure.
More information12 kw Electric Tankless Water Heater Troubleshooting Guide
Technical Service Bulletin 12 kw Electric Tankless Water Heater Troubleshooting Guide Models: AE12, RP12T, US12 DANGER: ELECTRIC SHOCK ELECTRICITY IS EXTREMELY DANGEROUS. TAKE EXTRA PRECAUTIONS AND DISCONNECT
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationDESIGN GUIDELINES AND TECHNICAL STANDARDS
DESIGN GUIDELINES AND TECHNICAL STANDARDS Date of Issuance: January 1, 2014 DIVISION 22 PLUMBING SECTION 22 1118 DOMESTIC WATER DISTRIBUTION SYSTEM 1. General: This section outlines general requirements
More information...WHY WAIT? IT S TIME TO SWITCH TO A NORITZ TANKLESS
...WHY WAIT? IT S TIME TO SWITCH TO A NORITZ TANKLESS If you answered YES to one or more of these questions, maybe it s time to replace your old tank-type water heater with a new, high-efficiency, tankless
More informationShay Plumbing IX - Feed Water Pipes
Shay Plumbing IX - Feed Water Pipes Nelson Riedel Nelson@NelsonsLocomotive.com Initial: 11/28/03 Last Revised: 06/06/2004 Feed Water Pipe Orientation: Photos of a couple of the Cass shays were reviewed
More informationLow kw Electric Tankless Water Heater Troubleshooting Guide
Technical Service Bulletin Low kw Electric Tankless Water Heater Troubleshooting Guide Models: AE3.4, AE7.2, AE9.5, RP1P, RP2P, RP3P, RP7P, RP9P, US3, US6, US7, US9 DANGER: ELECTRIC SHOCK ELECTRICITY IS
More informationCEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.
CEHA Fall Chloride Workshop Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc. Being Aware of a Problem The sodium and chloride problem is nothing new. What is new is
More informationKITCHEN PLANNING GUIDE
KITCHEN PLANNING GUIDE STEP-BY-STEP PLANNING GUIDE FOR A CAPTIVATING KITCHEN DESIGN LINE KITCHENS SHOWROOM & FACTORY started GETTING Maybe you are in a new home but the kitchen is not right for you. Or
More informationDistrict heating at home. It s simple.
District heating at home. It s simple. Trouble with Nuon district heating? Call 0800 0513 (free). Available 24/7. Contents District heating: simple, safe and environmentally friendly 3 Our delivery set
More informationREGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 05 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed
More informationHow much do you know about conserving H2O? Read interesting facts about water conservation focused on the toilet from Fluidmaster
H2O Facts How much do you know about conserving H2O? Read interesting facts about water conservation focused on the toilet from Fluidmaster Is my toilet leaking? What causes it to leak? How do I fix it?
More information8KITCHEN OUTDOOR PLANNING GUIDE OUTDOOR KITCHEN THINGS TO KNOW BEFORE INSTALLING AN
OUTDOOR KITCHEN PLANNING GUIDE THINGS TO KNOW BEFORE INSTALLING AN OUTDOOR 8KITCHEN 1 TABLE OF CONTENTS 03 INTRODUCTION 04 05 06 07 08 09 10 10 11 YOU LL REGRET NOT GETTING A PROFESSIONAL DESIGN YOUR KITCHEN
More informationMONTECITO FIRE PROTECTION DISTRICT
Section 5a MONTECITO FIRE PROTECTION DISTRICT FIRE PROTECTION PLAN Residential Automatic Fire Sprinkler System Installations I Automatic Fire Sprinkler System Standards 1. Definition and Standard: An automatic
More informationComplete Shower Room Installation Guide and Operation Manual. Model 855
Complete Shower Room Installation Guide and Operation Manual Model 855 IMPORTANT PLEASE READ BEFORE STARTING ASSEMBLY ALL STEAM SHOWERS REQUIRE TWO PEOPLE TO ASSEMBLE THEM IF YOU ARE NOT AT ALL THE DIY
More informationINFORMATION FOR THE PROSPECTIVE GEOTHERMAL HOME BUYER
INFORMATION FOR THE PROSPECTIVE GEOTHERMAL HOME BUYER Kevin Rafferty PE Geo-Heat Center Introduction Welcome to Klamath Falls! If you are not from the area a geothermally heated home may be something unfamiliar
More informationMODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS
MODEL EH ELECTRIC BOILER EH-08-135S through EH-40-135S 3 wire 120/208V, 120/240V single phase EH-12-345S through EH-40-345S 4 wire 120/208V three phase WYE OPERATION AND INSTALLATION INSTRUCTIONS CONTENTS....................................PAGE
More informationMarch
March 2006 FiveTime Winner 5 2005 APEX Awards www.pmengineer.com Scalding is a traumatic event that always happens to someone else, on someone else s project, or in someone else s facility. This is much
More informationACT D MAND KONTROLS System FACTS AND QUESTIONS (FAQ)
ACT D MAND KONTROLS System FACTS AND QUESTIONS (FAQ) General Questions Page 2 How It Works Page 3-6 Mechanical Questions Page 7-9 1 GENERAL QUESTIONS: 1) How long can I expect the system to last? Life
More informationWHERE THE WATER IS FLOWING
WHERE THE WATER IS FLOWING New Trends in Plumbing Technology By Renee Changnon, rchangnon@nrha.org When you think about all of the categories within a home improvement store where technology has had an
More informationAPPENDIX A. A 3.2 Determine the elevation of the highest. A 3.3 Subtract the sum of loss in static pressure
APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes
More informationAutomatic Temperature Controller (ATC)
NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet
More informationScalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update
Special Report_0408.qxd 2/24/04 11:30 AM Page 2 SCALDING RISK LEGIONELLA AGING POPULATION HIDDEN COSTS CODES & STANDARDS The Rising Need for Advanced Shower Valve Technology Scalding Now a Healthcare Worry
More informationOUR GOAL IS TO SERVICE your product needs knowledgeably, accurately and on time DISTRIBUTION NETWORK
At Wolseley, our success lies in the trusting relationships that our people have developed with customers throughout Canada. We ve made it a priority to recruit the best people, and we invest in ongoing
More informationHome. One Source For All Your Potable Water Needs
Home One Source For All Your Potable Water Needs AMX300 Thermostatic Mixing Valve Kit Installation that s literally almost no sweat. Kit includes mixing valve, cold water tee, flexible 8" or 11" metal
More informationSaving water in Scotland? Really? Free water saving gadgets to help you use water wisely and save energy and money
water in Scotland? Really? Free water saving gadgets to help you use water wisely and save energy and money At Scottish Water we are always working so the water cycle never stops. And because water is
More informationWhat Size Electric Tankless Water Heater Do I
What Size Electric Tankless Water Heater Do I Need For My House According to the EPA, residential electric water heaters are the second highest energy users in American What size tankless water heater
More informationCONTENTS TABLE OF PREFACE- A QUICK GLANCE AT THE GEOTHERMAL INDUSTRY INTRODUCTION- NEARLY HALF OF ALL HVAC SYSTEMS ARE INCORRECTLY INSTALLED
TABLE OF CONTENTS PREFACE- A QUICK GLANCE AT THE GEOTHERMAL INDUSTRY INTRODUCTION- NEARLY HALF OF ALL HVAC SYSTEMS ARE INCORRECTLY INSTALLED COMPLAINT 1: HIGH OPERATING COSTS COMPLAINT 2: EXCESSIVE REPAIRS
More informationSTRESS-FREE RENOVATIONS By Nick Brownlee, Managing Director Procuro Building and Renovation
STRESS-FREE RENOVATIONS By Nick Brownlee, Managing Director Procuro Building and Renovation BUILDING & RENOVATION RENOVATING YOUR HOUSE INTO YOUR DREAM HOME IS A PRIVILEGE WE ENJOY EVERY DAY. Procuro Building
More informationAquamixa. Thermo. Thermostatic shower valve with manual bath fill
Aquamixa Thermo Thermostatic shower valve with manual bath fill Aquamixa Thermo thermostatic shower valve with manual bath fill installation instuctions page 1 Shower systems Aquamixa Thermo (300.01) with
More informationShowering solutions. Stylish mixer showers new from Aqualisa Dream Aspire. featuring Harmony shower heads. SL Colt. DL Siren
Showering solutions Stylish mixer showers new from Aqualisa Dream Aspire DL Siren SL Colt featuring Harmony shower heads Innovative ideas... Smart solutions Whether you install our showers or use our showers,
More informationCrawl Space 101. Any mold or mildew that may be living in your crawl space is being circulated through your entire home.
Crawl Space 101 Your crawl space was designed to promote air circulation through your home and allow easy access to plumbing, wiring and other systems in your home. The air in your crawl space doesn t
More informationWALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationSAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION
Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING
More informationBar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1
Midas Plus Bar valve with fixed and adjustable shower heads Installation guide Midas Plus installation instructions Page 1 Midas Plus Midas Plus installation instructions Page 2 Components Literature not
More informationSubmittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION
! APPROXIMATE DIMENSIONS A = 3-3 B = 3-10-1/2 C = 4 D = 9-1/2 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
More informationSeven Things You Must Know Before Hiring a Lawn Sprinkler Service
Seven Things You Must Know Before Hiring a Lawn Sprinkler Service Seven Things You Must Know Lawn Sprinkler Service Copyright All Rights Reserved 1 Introduction There is a reason why owning your own home
More informationNeed a Storm Damage Expert
? Need a Storm Damage Expert LIKE MOST PEOPLE, YOU PROBABLY ANSWERED I DON T KNOW. THAT S WHY OUR GUIDANCE IS INVALUABLE! WELCOME TO ROOFING 2.0 OR VISIT US AT ROOFINGANNEX.COM PROPERTY DIAGNOSTICS RESTORATION
More informationADVANCE ECB ELECTRIC COMBINATION BOILER
ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC
More informationSAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
224500 SAFETY SHOWERS AND EYEWASHES Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These
More informationMeeting the One-Cup Challenge
42 TECHNICAL SERIES HIGH PERFORMANCE HOT WATER SYSTEMS JANUARY/FEBRUARY 2010 OFFICIAL Meeting the One-Cup Challenge A SERIES ON HIGH PERFORMANCE HOT WATER SYSTEMS PART THREE: CENTRAL CORE PLUMBING About
More informationAQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide
AQ150:Midas 10/9/15 14:50 Page 1 AQ150 Thermostatic bar mixer valve with adjustable head Installation guide AQ150:Midas 10/9/15 14:50 Page 2 Important information Introduction The product is an exposed
More informationHow to install Solar Water Heater Systems?
PIK-ASS International Ltd., Part., 42/2 Moo 2 (Kor Klang Road), T. Nonghoi, A. Muang, Chiang Mai 50000 How to install Solar Water Heater Systems? There are several system configurations possible. The following
More informationWhy do I need a water softener?
Why do I need a water softener? Is something wrong with my water? Dust, particles, smog Air pollution Rain Evaporation Rain Evaporation Most water contains more than water. Almost all of the water found
More informationMODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS
MODEL EH ELECTRIC BOILER EH-08-135-S2 through EH-40-135-S2, single phase, 3 wire, 120/208V, 120/240V EH-12-345-S2 through EH-40-345-S2, three phase, WYE, 4 wire, 120/208V For three phase, 120/240V consult
More informationDualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System
DualPak Series 6900 FILE NO: 62.11 DATE: Feb. 15, 1999 SUPERSEDES: 62.11 DATE: Sept. 28, 1995 DualPak 6900 Series Booster System D U A L P A K 6 9 0 0 Armstrong proudly presents the Series 6900 DualPak
More informationELECTRIC WATER HEATERS
ELECTRIC WATER HEATERS SAVE MONEY AND ENERGY WITH AN ELECTRIC WATER HEATER Whether you re replacing a furnace or water heater, choosing new appliances, or building a new home, how well you use energy has
More informationSubmittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified
! APPROXIMATE DIMENSIONS A = 3-11 B = 3-9 C = 4-1/2 D = 1-1 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
More informationSETS Systems * HOMEOWNER MANUAL *
SETS Systems * HOMEOWNER MANUAL * S.E.T.S. Systems Tankless Water Heater System SETS SYSTEMS, INC. 6900 N.W. 72 AVENUE - MIAMI - FLORIDA, 33166 Toll Free: 877-649-8589 Tel: 305-863-9420 Fax: 305-863-9418
More informationhome Warm Up with a New Water Heater #HomeCOMFORT Winter 2019
Winter 2019 home Warm Up with a New Water Heater The #HomeCOMFORT Edition NJR Family of Companies: New Jersey Resources NJR Home Services NJR Energy Services NJR Clean Energy Ventures Winter 2019 The Wait
More information2725 SW 91st Street Gainesville, FL Lic (352)
Paula C. We don't feel that there were any areas that HKB fell short of our expectations. Honestly, it's hard to narrow down the areas that we were most satisfied with. We were especially happy (and grateful)
More informationSEISCO APPLICATIONS & DIAGRAMS
ALICATIONS & DIAGRS A. Seisco Selection Criteria B. Residential Floor lan Diagrams 1. Standard One Story Home Options 2. Standard Two Story Home Options 3. One Story Booster for Quicker Response C. Application
More informationREGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE
No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced by
More informationDene Bath Shower Mixer
Dene Bath Shower Mixer Installation and operating instructions The showerhead and hose supplied with this product are an integral part of the safety of your shower. Failure to use genuine Triton parts
More informationIrrigation for Lawns and Gardens
Irrigation for Lawns and Gardens Contents Planning the Irrigation System... 3 Sprinkler Irrigation... 3 Drip Irrigation... 6 The Distribution System... 8 The Water Source... 10 Backflow Prevention... 11
More informationECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION
- 3 5 kg/cm C AS SE 7-3 5 THEMOSTATIC H - 3 5 3 5 - COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Submittal Data Sheet S-5Z-LF August, MEGATON LEAD FEE MODEL NB-LF HOT & COLD INLETS MIXED OUTLET ¼ ETUN
More informationCoastal Community Convinced about Vacuum Sewers
Coastal Community Convinced about Vacuum Sewers By Steve Gibbs The relationship between cost and value is usually very predictable. The quality of a product or service typically increases with the price.
More informationHoneywell Water Solutions. Thermostatic Mixing Valves
Honeywell Water Solutions Thermostatic Mixing Valves AMX300 Thermostatic Mixing Valve Kit Key Features and Benefits Kit includes mixing valve, cold water tee, flexible 8" or 11" metal connectors, and thermostrip
More information4 STEPS TO YOUR NEW KITCHEN Planning guide 2015
4 STEPS TO YOUR NEW KITCHEN Planning guide 2015 INSTALLATION GUIDE 4 steps to your new kitchen This brochure is your guide to measuring, planning, ordering and installing your IKEA kitchen. Inside you
More informationDOMESTIC WATER PACKAGED BOOSTER PUMPS
DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot
More informationAmerican Dish Service
1 American Dish Service INSTALLATION INSTRUCTIONS Model 5 CD (LF or RF) Available with Left Front or Right Front door Available in 90, 120, 150 second Time Cycles Door type, Double Rack, Chemical Sanitizer,
More informationBUYING GUIDE Bathroom showers
BUYING GUIDE Bathroom showers DESIGN H Preutz/N Karlsson CARE INSTRUCTIONS Clean with a soft cloth dampened with water and a mild washing-up detergent or soap. Never use scouring powder, steel wool or
More informationHome Improvement Ebooks Gratuit
Home Improvement 1-2-3 Ebooks Gratuit Home Improvement 1-2-3 is a workbench classic. The new editionâ more than 600 projects, thousands of color photos, detailedâ illustrations, charts, and graphs, and
More informationabout your house Before You Start an Energy-Efficient Retrofit Mechanical Systems
about your house CE 28i Before You Start an Energy-Efficient Retrofit Mechanical Systems One of the best ways to make your home more comfortable, healthier and less expensive to operate is to upgrade the
More informationNatural Concept Landscape Co., Inc C SR9 SE Snohomish, WA Office-(360)
Natural Concept Landscape Co., Inc. 20318-C SR9 SE Snohomish, WA 98296 Office-(360)668-8530 E-mail-cory@nclandscape.com Below we have explained in a step by step manner how to properly winterize irrigation
More informationSERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job
SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,
More informationSEALED THERMAL STORE
ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL
More informationLEAK DETECTION GUIDE
LEAK DETECTION GUIDE Your Guide to Home Water Conservation CITY OF BELLEVUE UTILITIES WATER & SEWER DEPARTMENTS LEAK DETECTION GUIDE PAGE: 1 WHERE TO START If you receive a high water bill, or think there
More informationSHOWHOUSE BY MOEN VERTICAL SPA. Design Guide
SHOWHOUSE BY MOEN VERTICAL SPA Design Guide Design A PREMIUM CUSTOM SHOWER STARTS WITH EXCEPTIONAL DESIGN. DESIGN How does one elevate an ordinary shower into something extraordinary? With a ShowHouse
More informationBefore using your machine, you must familiarize yourself with all of its components.
USE AND MAINTENANCE MANUAL FOR THE FOAMTEC 1800 NOTE: As with all electrical equipment, care and attention must be exercised at all times during its use, in addition to ensure that routine and preventative
More information1year. The natural connection between energy savings and a balanced two-pipe system.
The natural connection between energy savings and a balanced two-pipe system Our Renovation + Solution is your automatic technology for perfect Hydronic Balancing of communal installations. 1year payback
More informationBath Shower Mixer
86004490 Bath Shower Mixer Installation and operating instructions The showerhead and hose supplied with this product are a safety critical part of your shower. Failure to use genuine Triton parts may
More informationRAINWATER HARVESTING. An Overview of Rainharvesting Systems
RAINWATER HARVESTING An Overview of Rainharvesting Systems Validation number: CPDSAIA 14-05 Prepared by: Patrick Rosslee Content Rainwater as a resource Rainwater use around Domestic and Commercial Buildings
More informationLABOUR RATES FOR PLUMBING CONTRACTORS. A guide to the labour costs of plumbing works LABOUR RATES FOR PLUMBING CONTRACTORS
LABOUR RATES FOR PLUMBING CONTRACTORS A guide to the labour costs of plumbing works MORE MONEY IN YOUR POCKET September 06-1 - Increasers Labour Time Required In Hours DURAVENT STYLE INCREASER 75-100MM
More informationCHAPTER VI BUILDING PLUMBING
CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems
More informationFT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER
701 S Ridge Avenue, Troy, OH 45374 Item # Quantity WITH BLOWER DRYER FLIGHT-TYPE DISHER C.S.I. Section 11400 STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital
More informationDesign your Ideal City. Adrian A.-A.
Design your Ideal City Adrian A.-A. My Vision I would love to create a city with a futuristic downtown with high rises and skyscrapers while staying environmentally friendly. As a coastal city on a large
More informationGuidelines for Specifying Structured Plumbing Systems January, 2007
Guidelines for Specifying Structured Plumbing Systems January, 2007 PART I - GENERAL A. Description This section includes requirements for materials for the installation Structured Plumbing systems for
More informationHelping you to understand your water use
022BWN0144 Helping you to understand your water use wessewater.co.uk Your water use Step 1 work out how much water you use If you live in a metered property, your water bill is based on the amount of water
More informationMains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.
DPS Hi-Flow Mains Pressure Hot Water from an existing vented copper cylinder... Converts an existing hot water cylinder to provide potable mains pressure hot water at high flow rates to all existing outlets.
More informationCER-1 & CER-2 Installation & Testing Instructions
CER-1 & CER-2 Installation & Testing Instructions i Read all installation instructions completely before installing this device. 1 2 3 INTRODUCTION This document details the installation procedure for
More informationMONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.
MONITRON II MODEL EH-M2 ELECTRIC BOILER Four stage electronic control with energy saving and other features. EH-08-135-M2 through EH-40-135-M2 3 wire 120/208V, 120/240V single phase EH-12-345-M2 through
More informationGETTING THE BEST DEAL ON YOUR NEW BOILER
GETTING THE BEST DEAL ON YOUR NEW BOILER Most blogs and articles about boilers will try to excuse themselves for existing; it s almost like apologising for bringing up the subject. Boilers aren t exciting
More informationThe Brand Built For Professionals
The Brand Built For Professionals Bradford White The Brand Built For Professionals AMERICAN MADE AMERICAN OWNED WHOLESALE ONLY Committed to American Manufacturing, Wholesale Distribution, and Professional
More information1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)
1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors) 1. What is the minimum diameter for a non-hydraulically calculated Class III fire standpipe that is part of a combined
More informationOperation / Installation Manual
Operation / Installation Manual RINNAI PRESTIGE and RINNAI SUNMASTER Solar Split Systems Electric and Gas Boosted NOT E The appliance must be installed, commissioned and serviced by an authorised person
More informationDAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL
BY DAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL In the September/October 2005 issue of HPAC Magazine, the case was made for reducing head pressure to increase compressor efficiency, thereby lowering its
More informationMorco House Riverview Road Beverley HU17 0LD
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi
More informationAmerican Dish Service
1 American Dish Service INSTALLATION INSTRUCTIONS Model AF 3D S, AFC 3D S, AFB Available in 90, 120, 150 second Time Cycles Door type, Single Rack, Chemical Sanitizer, Dump & Fill Dishmachine Listed by
More informationHigh Efficiency Commercial Gas Water Heaters
High Efficiency Commercial Gas Water Heaters 500,000 to 1, 300,000 Btu/hr Less Than 30 ppm NOx Up to 87% Thermal Efficiency The High-Efficiency, High-Output Compact Water Heater First Power-Fin production
More informationIt won t just meet your hot water needs. It will exceed them. RH180 Hybrid Tank-Tankless Water Heater
It won t just meet your hot water needs. It will exceed them. RH180 Hybrid Tank-Tankless Water Heater More of what you want. When you want it. The Rinnai RH180 Hybrid Tank-Tankless Water Heater delivers.
More information