IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

Size: px
Start display at page:

Download "IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1"

Transcription

1 Instruction Manual IA Inlet Actuator IA Inlet Actuator Models: IA0090 IA0090P Munters Corporation, March 2017 QM1235r1 1

2 IA Inlet Actuator Manual for use and Maintenance Thank You: Thank you for purchasing a Munters IA Inlet Actuator. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Description: The IA0090 motor gearbox is a maintenance-free, compact drive unit for accurately opening and closing air inlet flaps, air valves and ventilation curtains in livestock houses and crop storage buildings. The IA0090 motor gearbox features a self-braking worm gear transmission. This transmission ensures that the drive shaft is not rotatable when the drive unit is stopped. The combination of carefully matched pinion and worm reductions results in a quiet mechanical transmission. The IA0090 motor gearboxes feature a power switching integrated linear limit switch system with duty and safety switches with an excellent switching precision of the end positions. The maximum switching range of the limit switch system equates to 55 revolutions of the drive shaft. With use of an optional potentiometer built-in set, it is possible to precisely feedback intermediate and end positions to a (climate) computer. The IA0090 motor gearboxes are finished with a blue powder coating and are supplied including mounting bolts and spring washers. IA0090 motor gearboxes: Drive torques of 1000 lb. in.j 1.2 at 60 Hz mains frequency; Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes; Provided with a two-sided output drive shaft for mounting one winch or belt drum or two16-tooth 1/2 x5/16 zinc-plated sprockets for chain couplings; Manual drive enabled by means of a hexagon socket in electric motor shaft; Electric motors are standard tropic-proof and conform to protection class IP55; Available as 1-phase 115 V (60 Hz) electric motor with UL and CSA approval. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at or by at aghort.info@munters.com. Conditions and Limitations: Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 2 QM1235r1 Munters Corporation, March 2017

3 Index Chapters Page 1. Unpacking the Equipment 1.1 Technical specifications IA0090 motor gearbox Configurations IA0090 motor gearbox Options for IA0090 motor gearbox Dimensions IA0090 motor gearbox 5 2. Installation Instructions 2.1 Mounting the IA0090 motor gearbox Mounting the drum, winch belt and couplings (configuration 1) Pre-winding the winch belt onto the belt drum (configuration 1) 8 3. Connection and Operations 3.1 Connection and operation - abbreviations Connecting the control components: switch materials and cable lenghts Overview: connections and elements for Operating & Setting Rotational directions and end positions IA0090 motor gearbox Wiring diagrams IA0090 motor gearbox Setting the limit switch system Potentiometer installation set: installation Potentiometer table IA0090 motor gearbox (i=1,0) Maintenance 4.1 Maintenance IA0090 motor gearbox 19 Munters Corporation, March 2017 QM1235r1 3

4 About the Equipment Technical Specifications IA0090 Motor Gearbox Mechanical Torque Speed Winch belt speed Winch belt length Drive unit Weight 1000 lb. in. 1.2 rpm inch/min 39.4 inch Self-locking 34.2 lb Electrical Supply voltage (A ) Maximum current (A ) Power 115 V 2.5 A 90 W Environment Protection class Operating temperature IP55 0 tot 40 C (32 tot 104 F) 1.2 Configurations IA0090 Motor Gearbox The IA0090 ships in 2 boxes, Box 1 of 2 is the Gear Motor and Box 2 of 2 is the installation kit. The IA0090 is standard delivered with a 1-phase motor: A - 115V The IA0090 is standard delivered with limit switch system and mounting kit. Configurations include double belt drum, Belt Drum w/option to use cables. Options: Potentiometer Options and accessories are ordered separately. CONFIGURATIONS : Belt drum Ceiling Mount Wall Mounts 4 QM1235r1 Munters Corporation, March 2017

5 Chapter 1 About the Equipment Items to Order Seperately: IA0090, IA0090P Drum Kit with Mounting Bracket AC Options for IA0090 Motor Gearbox Potentiometer: Position feedback IA0090P An optional potentiometer built-in set (AC1429) for the IA0090 motor gearbox. Position feedback which works in combination with the limit switch system. The built-in set with potentiometer makes it possible to signal with precision to a (climate) computer, not just the start and end positions of the limit switch system, but also all the intermediate positions of the driven system. AC1429 Specifications Resistance: 5kΩ (R5K) Revolutions: 10 (S10) AC Dimentions IA0090 Motor Gearbox 3.1" 6.2" 6.9" 7.87" 5.79" 5.05" 4.88" 7.55" 6.61" 6.55" 4.72" 5.94" 12.64" Munters Corporation, March 2017 QM1235r1 5

6 Installation Instructions Mounting the IA0090 Motor Gearbox. Mount the IA0090 motor gearbox according to the following instructions: Always use an allowed mounting position as shown in image 3.1.! CAUTION Please ensure that the IA0090 is mounted securely, so that the building structure can sufficiently absorb the forces applied.! Attention: When mounting the IA0090, ensure that the motor cover remains accessible so you will have no problems connecting, setting and operating the IA0090 *Please observe the following allowed mounting positions when installing the IA0090 Motor Gearbox Image 2.1 Use the M10 bolt and washer from the mounting kit to mount the plates to the gearbox. Mounting IA0090: Belt Drum - Wall Mount Mount the mounting plate for wall assembly to the IA0090 as follows: IA0090, ACTUATOR MOUNTING BRACKET M10 bolt M10 SPLITLOCK WASHER M10x20 BOLT 6 QM1235r1 Munters Corporation, March 2017

7 Chapter 2 Installation Instructions Mounting IA0090: Belt Drum - Ceiling Mount (Configuration 1) Mount the square mounting plate to the IA0090 by choosing option 1 (side) or 2 (foot). IA0090, ACTUATOR MOUNTING BRACKET M10 SPLITLOCK WASHER M10x20 BOLT Configuration Mounting the Drum, Winch Belt and Couplings Mount the drum, winch belt (single or double) and couplings for the IA0090 as follows: KEY NUT DOUBLE DRUM DISC BELT (2) DRUM SPACERS M6x80 BOLT SINGLE DRUM DISC Munters Corporation, March 2017 QM1235r1 7

8 Chapter 2 Installation Instructions 2.3 Pre-winding the Winch Belt onto the Belt Drum To safely use the belt drum and winch belt of the IA0090 it is necessary to pre-wind the belt at least ½ a revolution onto the drum. Belt drum with single or double belt: At least ½ revolution! CAUTION Not pre-winding the winch belt may result in injury at high belt or drum loads. 8 QM1235r1 Munters Corporation, March 2017

9 Connection and Operations Connection and Operation: Abbreviations Symbol A B CW (A) CCW (B) ESU K1 K2 Description Endposition A Endposition B Clockwise rotational direction (A) Counterclockwise rotational direction (B) Limit switch system Connection block Connection block Potentiometer L1, L2 Power source M N P PS Electric motor Neutral conductor Potentiometer Potentiometer installation set P71, P72* Contacts for automatic control (open or closed). PE Q41 S1 S11 S12 S21 S22 S111 U1 V1 W1 Z1 Z2 PTO R * Suitable for inductive load of 115/220 V - 2,5 A Ground (Earth Contact) Motor Safety Switch Toggle switch (3 positions) Duty switch limit switch system A Duty switch limit switch system B Safety switch limit switch system A Safety switch limit switch system B Manual switch Stop - Open - Close - Automatic Motor connection (U1) Motor connection (V1) Motor connection (W1) Gear Wheel Threaded Shaft (Potentiometer Set) Gear Wheel Potentiometer Shaft (Potentiometer Set) Protection Thermal Overload (Switch) Relay 3.2 Connecting the control componets: Switch Materials and cable lengths ATTENTION: Please use only suitable control components and switch materials. Make sure you are using the correct equipment by consulting the information on the control componets and switch materials. 3.3 OVERVIEW: Connections and Elements for Operating & Setting The overview in image shows the most important connections, parts and elements for operating and setting a IA0090 motor gearbox. As shown in image 3.3.1, remove the limit switch cover of the gearbox. TIP: Cover in image is also removed for a complete overview. However it is not nessesary to remove cover in this manual. Munters Corporation, March 2017 QM1235r1 9

10 Chapter 3 Connection and Operations Unscrew the four bolts and remove the limit switch cover while the gasket stays in place. 1. Limit switch cover 2. Gasket 3. Bolts 4. Cover electric motor Image The overview of a IA0090 motor gearbox. The detailed diagrams for connecting are shown in Step 3.5 Image QM1235r1 Munters Corporation, March 2017

11 Chapter 3 Connection and Operations 3.4 Rotational Directions and End Positions IA0090 Motor Gearbox The rotational direction for the IA0090 is Clockwise [CW] (A) which is twords the motor and Counter Clockwise [CCW] (B) which is away from the motor. Also visable are the corresponding limit switches for setting the end positions A and B. See figure below. Based on where the IA0090 and inlets are mounted and the direction the belt is wrapped on the drum, determine which direction will be open and which will be close. 3.5 Wiring Diagrams IA0090 Motor Gearbox Two wiring diagrams are applicable during installing and setting of the IA0090 gearbox. A temporary and a permanent diagram are used in a number of steps according to Step 3.5. Temporary connections (diagram 3.5.2): This is only used for setting switch, according to Step 3.6, prior to making the permanent connections of the IA0090 gearbox. Therefor a Temporary Power Cable is connected to the switch. Permanent connections (diagram 3.5.4): Make the permanent connections of the IA0090 gearbox after setting of the switch. TIP: If the operation of position feedback is applicable, installation and setting of a potentiometer (P) is done separately in Step 3.7 and Step 3.8.! CAUTION The IA0090 motor gearbox is standard delivered with switch S1 in stop position. Switch S1 is still in STOP position when starting temporary or permanent connections! S1 Stop! Munters Corporation, March 2017 QM1235r1 11

12 Chapter 3 Connection and Operations Connect the Temporary Power Cable. The image and the diagram below show the connections of a Temporary Power Cable. Image IA0090 Image Go to Step 3.6 and set the Limit Switch System prior to the permanent connections. Remove the Temporary Power Cable. 12 QM1235r1 Munters Corporation, March 2017

13 Chapter 3 Connection and Operations Make the permanent connections. The image and the diagram below show the permanent connections of the IA0090 gearbox. CCW (Counter Clockwise) CW (Clockwise) GROUND NEUTRAL Image Diagram * Suitable for inductive load of 115V - 2,5 A IA0090 ATTENTION: When setting the Limit Switch after the permanent connections, make sure that S111 and P71 (or equivalent parts) are configured toprovide power to L1 (13) of connection block K1! TIP: Reverse the direction of rotation of the IA0090 if desired. The direction of rotation can be turned by changing connections 12 and 13 (L2 and L1) in the connection block K1. Munters Corporation, March 2017 QM1235r1 13

14 Chapter 3 Connection and Operations 3.6 Setting the Limit switch system Delivery: Make the connections from the controller to the actuator terminal block (K1) depending on which direction is Open and which is Close. See Image Terminal Block (K1) Threaded Shaft End Position (B) End Position (A) Toggle Switch (S1) Image Textured Brass Nut Set Screws in Adjusting Ring Setting the Limits: See Image Put switch (S1) into Stop position. 2. Apply power to the Clockwise [CW] (A) terminal Find the Allen Wrench that ships with the actuator. 4. Loosen the (2) Set Screws on each Adjusting Ring, at each end of the threaded shaft. Setting the Clockwise [CW] (A) limit: 1. Put switch (S1) into CW (auto) position. Image When end position [CW] (A) is reached put switch (S1) back to Stop. 3. On the [CW] (A) end, turn the Textured Brass Nut hand tight against the stop. 4. Now turn the Adjusting Ring over the Textured Brass Nut so far, that the working switch is just connected by the long Adjusting Screw. 5. Now tighten the Set Screws firmly on the Textured Brass Nut. The Adjusting Ring cannot turn on the Brass Nut anymore. Setting the Counter Clockwise [CCW] (B) limit: 1. Put switch (S1) into CCW position. 2. When end position [CCW] (B) is reached put switch (S1) back to Stop. 3. On the [CCW] (B) end, turn the Textured Brass Nut hand tight against the stop. 4. Now turn the Adjusting Ring over the Textured Brass Nut so far, that the working switch is just contacted by the long Adjusting Screw. 5. Now tighten the Set Screws firmly on the Textured Brass Nut. The Adjusting Ring cannot turn on the Brass Nut anymore. The Limits are now set. 14 QM1235r1 Munters Corporation, March 2017

15 Chapter 3 Connection and Operations ATTENTION: If the motor gearbox is manual operated by means of the hexagon socket in the electric motor shaft, with an limit switch system which is set, it has to be checked that the end positions of the system will not be exceeded. This can cause damage to the limit switch system, as a result of which the limit switch system will not function well anymore. Operating mode Make sure the switch S1 is put in CW (A)/Auto position when permanent connections are done and setting of the Switch is finished. Place the limit switch cover1, with the gasket 2 still in place, and mount it with the four bolts. See image Image TIP: If the feedback option is applicable, then first install and set the potentiometer (P) according to Step 3.4 and Step 3.5. Munters Corporation, March 2017 QM1235r1 15

16 Chapter 3 Connection and Operations 3.7 Potentiometer Installation Set: Installation For an IA0090P, the Potentiometer set comes pre-installed in the unit for a typical installation with a 1m belt we recommend using the gears Z1 25 and Z Slide Potentiometer with gear towards the other gear without turning the shaft of the pot, so that the teeth on each gear nest together and tighten the pot nut with the hex key wrench. See Figure A. 2. The Potentiometer is pre-wired to the terminal bock K2. Make the connections between the controller and terminal block K2. See Figure B. If the Pot is changing voltage from low in the open position to high in the closed position then reverse the red and black wire on the controller side of terminal block K2. The Potentiometer installation is now complete. For a 2m belt use gear?? on the??? shaft. For a 3m belt use gear?? on the??? shaft. Potentiometer with Gear Gear on IA Shaft Figure A Terminal Block K2 RED WHITE BLACK Figure B 16 QM1235r1 Munters Corporation, March 2017

17 Chapter 3 Connection and Operations 3.8 Potentiometer table IA0090 motor gearbox (i=1,0) The table below can be used to select the necessary gearwheels when fitting a potentiometer and installation set in an IA0090 motor gearbox. The table shows the maximum number of revolutions of the drive shaft of the IA0090 motor gearbox. A range of 9 revolutions of the potentiometer has been chosen for maximum precision and sufficient reserve rotations when using a potentiometer. If the desired number of revolutions falls below the minimum value given, a 5-turn potentiometer may be used. In that case, the values in the table that give the maximum number of revolutions of the drive, should be divided by 2. IA0090 Munters Corporation, March 2017 QM1235r1 17

18 Maintenance Maintenance IA0090 Motor Gearbox Regularly check your IA0090 motor gearbox for operation performance and possible grease leakage. Inform your installer in case of grease leakage. Lubricant IA0090 SPH grease 1,9 lb IA Actuator by Munters Corporation, Lansing, Michigan U.S.A Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE Kista, Sweden. Phone , Fax Munters Corporation 2691 Ena Drive Lansing, MI U.S.A. Phone , Fax Australia Munters Pty Limited, Phone , Brazil Munters Brasil Industria e Comercio Ltda, Phone , Canada/US Munters Corporation Lansing, MI Phone , China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone , Denmark Munters A/S, Phone , India Munters India, Phone , Indonesia Munters, Phone , Italy Munters Italy S.p.A., Chiusavecchia, Phone , Japan Munters K.K., Phone , Korea Munters Korea Co. Ltd., Phone , Mexico Munters Mexico, Phone , Russia Munters AB, Phone , Singapore Munters Pte Ltd., Phone , South Africa and Sub-Sahara Countries Munters (Pty) Ltd., Phone , Spain Munters Spain S.A., Phone , Sweden Munters AB, Phone , Thailand Munters Co. Ltd., Phone , Turkey Munters Form Endüstri Sistemleri A.Ş, Phone , USA Munters Corporation, Lansing MI Phone , Vietnam Munters Vietnam, Phone , Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone QM1235r1 Munters Corporation, March 2017

BA2702-P Linear Actuator

BA2702-P Linear Actuator Instruction Manual Linear Actuator with Potentiometer BA2702-P Linear Actuator Model: BA2702-P QM1246r0 1 BA2702-P Linear Actuator Instructions for Use and Maintenance Thank You: Thank you for purchasing

More information

BA4000 Series Curtain Machine

BA4000 Series Curtain Machine Instruction Manual Aerotech Curtain Machine Motor Replacement BA4000 Series Curtain Machine Motor Replacement Kit Models: AC1436 AC1437 Munters Corporation, November 2017 QM1157r0 1 BA4000 Series Curtain

More information

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6 Instruction Manual Motor Kit for SW Shutter Motor Kit for SW Shutter Models: FA2685 Munters Corporation, November 201 QM1017r6 1 Munters Drive Motor Kit for SW Shutters Manual for use and Maintenance Thank

More information

AX51 with Munters Drive

AX51 with Munters Drive Instruction Manual AX51 with Munters Drive Fan Hanger Kit AX Hanger Kit and I Beam hardware AX51 with Munters Drive Fan Hanger Kit Models: FH1712 AX Hanger Kit AX51with Munters Drive Fan Munters Corporation,

More information

RC Series Discharge Cones

RC Series Discharge Cones Instruction Manual Discharge Cone RC Series for 14-26 Fans 26RC RC Series Discharge Cones Models: 14RC 16RC 18RC 24RC 26RC 24RC Munters Corporation, December 2017 QM1103r2 1 RC Series Discharge Cones 14,

More information

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01 Instruction Manual BI28SP Ceiling Inlet BI28SP Ceiling Inlet Bi-Flow, Spring Actuated Models: BI28SP BI28SP-01 Munters Corporation, May 2017 QM1111r1 1 BI28SP Inlet Instructions for Use and Maintenance

More information

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans Instruction Manual FM Munters Drive * Motor Replacement Kit for AX and VX Fans *Patents Pending FM Munters Drive Motor Replacement Kit Models: FM1136H FM1136L FM1236H FM1236L Munters Corporation, August

More information

Flatsided Discharge Cone Models: 54GC & 54GCX

Flatsided Discharge Cone Models: 54GC & 54GCX Instruction Manual FLATSIDED DISCHARGE CONE 54GC 54GCX Flatsided Discharge Cone Models: 54GC & 54GCX Munters Corporation, February 2014 QM1049r3 Flatsided Discharge Cone Manual for use and Maintenance

More information

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans Instruction Manual MD Munters Drive * Motor & Controller Replacement kit for AX and VX Fans *Patents Pending MD Munters Drive Motor and Controller Replacement Kit Models: MD-AX51xx-Hx MD-VX36xx-Hx MD-VX48xx-Hx

More information

VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan

VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan Instruction Manual Aerotech VX51 & VX55 with RC Cone and Munters Drive* *Protected by U.S. Patent No. 6,386,828, 6616404; 6953320 and other Patents Pending VX51 and VX55 with Munters Drive 51 and 55 Exhaust

More information

MFS. Manual for use and maintenance. + CE Declaration of conformity MFS. Air circulation fan. Models: MFS36 - MFS52. Ag/MIT/UmGB /13 rev1.

MFS. Manual for use and maintenance. + CE Declaration of conformity MFS. Air circulation fan. Models: MFS36 - MFS52. Ag/MIT/UmGB /13 rev1. MFS Manual for use and maintenance + CE Declaration of conformity MFS Air circulation fan Models: MFS36 - MFS52 Ag/MIT/UmGB-2085-04/13 rev1.1 MFS Manual for use and maintenance Revision: No. 1 of 15.04.2013

More information

AIR HEATING PRODUCTS

AIR HEATING PRODUCTS AIR HEATING PRODUCTS Air Heater GP EQUIPMENT GP High efficiency Protected against corrosion (housing is made from pre-coated galvanized steel, combustion chamber and heat exchanger are made from stainless

More information

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0 TU Manual for use and maintenance + CE Declaration of conformity TU600 - TU800 Chimney fan Ag/MIT/UmGB-2181-04/14 rev 1.0 TU600 - TU800 Manual for use and maintenance Original instructions This manual

More information

Positive Pressure Filtered Swine Facilities

Positive Pressure Filtered Swine Facilities OVER 350,000 SOWS PROTECTED BY MUNTERS Positive Pressure Filtered Swine Facilities Trust Experience 95% of all positive pressure filtered buildings in the US are designed and equipped with Munters Ventilation

More information

WDP. Installation manual WDP. Gutter system. Ag/MIT/UmEN /14 rev 1.0

WDP. Installation manual WDP. Gutter system. Ag/MIT/UmEN /14 rev 1.0 WDP Installation manual WDP Gutter system Ag/MIT/UmEN-2171-03/14 rev 1.0 Munters reserves the right to make alterations to specifications, quantities, dimensions etc. for production or other reasons subsequent

More information

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size AUTOMAT MANUAL 1 Technical Data Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size Type Divisions Dough Portions (in ounces) Plate Nos. 3 30 1.0 3.5 #35 4/40A

More information

Vacuum filters. Established for industrial dewatering

Vacuum filters. Established for industrial dewatering Vacuum filters Established for industrial dewatering Vacuum filters Vacuum filters Vacuum filtration is a well established technique used in industrial dewatering. Metso has successfully delivered and

More information

Drain Cleaning Machine K-39

Drain Cleaning Machine K-39 Drain Cleaning Machine K- 0 A- AUTOFEED Cable Chuck Pan Head Screw #0 - () Chuck Adapter Nose Piece Spiral Ring () Hand Grip Sleeve Clamp Springs () See Service Notes 0 Spacer Clips () Gasket Drum Front

More information

STT 3000 Series STT250 /150 Surge Protection Device Specifications

STT 3000 Series STT250 /150 Surge Protection Device Specifications STT 3000 Series STT250 /150 Surge Protection Device Specifications Part Number: 46188660-501 EN2I-6061 June 2011 Introduction This device is designed to give the Smart Temperature Transmitter maximum protection

More information

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company

More information

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS ASTRO ENVELOPE FEEDER AMC-2000-17 FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Thank you for purchasing the Astro Envelope Feeder. It is fast, efficient, reliable, and

More information

JAZ. Operator s Manual. Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160

JAZ. Operator s Manual. Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160 Operator s Manual JAZ GB Direct-fired Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160 IMPORTANT: Read and understand this manual before assembling, starting or servicing the heater.

More information

STYLE 3678 Conquest and 3878 Vanquish SST Monitor MOTOR DRIVE COUPLING REPLACEMENT INSTRUCTIONS

STYLE 3678 Conquest and 3878 Vanquish SST Monitor MOTOR DRIVE COUPLING REPLACEMENT INSTRUCTIONS STYLE 3678 Conquest and 3878 Vanquish SST Monitor DRIVE COUPLING REPLACEMENT INSTRUCTIONS Applies To: Zone &, Zone with Handwheel, Zone &, and Vanquish SST Monitors The following is intended to provide

More information

WAILEA OWNER S MANUAL

WAILEA OWNER S MANUAL WAILEA OWNER S MANUAL The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.

More information

M I S T E L I M I N AT I O N. Mist elimination in Flue Gas Desulphurization. The buck stops here.

M I S T E L I M I N AT I O N. Mist elimination in Flue Gas Desulphurization. The buck stops here. M I S T E L I M I N AT I O N Mist elimination in Flue Gas Desulphurization. The buck stops here. Are you seeing potential profits go up in smoke? In removing SO 2 from exhaust flue gases through flue gas

More information

Los Angeles Abrasion Machine HM-70A & HM-70AF

Los Angeles Abrasion Machine HM-70A & HM-70AF Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/24/2018 PHONE: 800-444-1508 740-548-7298 P.O. Box 200, Lewis Center, Ohio 43035-0200 E-mail: customerservice@gilsonco.com Website:

More information

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL 92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: 519-527- 2198 ABSOLUTE AIR INSTALLATION MANUAL 2014-04-10 PAGE 1 OF 18 REV 3 TABLE OF CONTENTS 1 INSTALLATION GUIDELINES FOR ABSOLUTE AIR FAN... 3

More information

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933 Two-hand Safety Control Module FF-SR Series FEATURES Complies with the Machinery Directive 98/37/EC and UL 508 Type III C per EN 574, Category 4 per EN 954-1 Inputs for two dual-contact pushbuttons 0,5

More information

User Guide Ted's Tumbler Model 2

User Guide Ted's Tumbler Model 2 User Guide Ted's Tumbler Model 2 CAUTION: READ ALL INSTRUCTIONS BEFORE USING TUMBLER. Changes from Version 1: Version 2 is essentially identical to version 1 except for the addition of belt guards and

More information

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail Drain Cleaning Machine K-0 Motor/Frame Assembly 0 0. Position Fan as Shown. Fan Mounting Detail Frame Assembly 0 Screw #0 - () Rubber Foot () 0 Carriage Bolt /" - x /" Flange Bearing () 0 Bracket 0 /"

More information

CL & CLG Clamp Mount Mixers

CL & CLG Clamp Mount Mixers CL & CLG Clamp Mount Mixers CL / CLG Series OWNERS MANUAL Warranty Our products are guaranteed against defective materials and workmanship, we will repair or replace such items as may prove defective at

More information

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Orrin A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010

More information

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz DAGNY LK Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 110V~60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A, PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F, PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF READ AND SAVE THESE INSTRUCTIONS

More information

THE HYTORC WASHER SYSTEM

THE HYTORC WASHER SYSTEM THE WORLD S MOST TRUSTED INDUSTRIAL BOLTING SYSTEMS For improved Safety, Speed, and Accuracy on every industrial bolting job, the HYTORC Washer is the most convenient and economical solution available

More information

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r Type 2 safety light curtain FF-SLD Series FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496-parts 1 and 2 European Norms 30 mm resolution for hand detection

More information

IMAGE V. Parts and Service Manual

IMAGE V. Parts and Service Manual IMAGE 0V Section II Parts and Service Manual (88B) CLARKE TECHNOLOGY Image Operator's Manual Page AUTHORIZED PERSONNEL MAINTENANCE To Access Pump Motor. Remove brush housing from machine. See "Brush Motor

More information

product manual H-1336D, H-1346D & H-1356D H-1336_46_56D_man_0609 Marshall Mechanical Compactors

product manual H-1336D, H-1346D & H-1356D H-1336_46_56D_man_0609 Marshall Mechanical Compactors H-1336_46_56D_man_0609 product manual H-1336D, H-1346D & H-1356D Marshall Mechanical Compactors Introduction Humbolt's Standard-Duty, 4-inch automatic compactors ease sample preparation through automatic,

More information

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE USER MANUAL ultra quiet fan INSTALLATION OPERATION MAINTENANCE Z0414808 rev A ISSUED 02/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and handling Safety Warning

More information

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate Instructions Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate 332517B EN For adapting a 60# Dyna-Star Pump for use with a 35# bucket. For professional use only. Part No.: Important Safety Instructions

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before

More information

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER ELECTRIC RADIANT OUTDOOR / INDOOR HEATER INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS Prior to installing and operating the heater, read these instructions

More information

SuperKlean Washdown Products

SuperKlean Washdown Products DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot

More information

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. Irene 52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz TABLE OF CONTENTS Tools and Materials Required... 1 Package Contents... 1 Safety Rules... 2 Mounting Options... 3 Hanging

More information

Essex 42 Ceiling Fan TOOLS AND MATERIALS REQUIRED Mounting options : Hugger & Drop mount

Essex 42 Ceiling Fan TOOLS AND MATERIALS REQUIRED Mounting options : Hugger & Drop mount 052-6961-2 10/14 This Noma product carries a limited ten (10) year warranty against defects in the motor, and a one (1) year warranty against defects in workmanship and materials. Trileaf Distribution

More information

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1 OPERATING MANUAL BAK Thermoplastic Welding Technology AG 1 SAFETY Danger to life Unplug the tool before opening it as live components and connections are exposed. Danger of fire and explosion in case of

More information

TOOLS AND MATERIALS REQUIRED

TOOLS AND MATERIALS REQUIRED 5 YEAR LIMITED WARRANTY Thank you for purchasing our product. It is our policy to furnish you with high quality products at a fair price. With proper installation your fan should provide you with years

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company

More information

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades. 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National

More information

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! FitchTM A Kichler Décor ceiling fan U.S. Patent Pending Kichler Lighting 7711 East Pleasant Valley Road

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions FJ-216 Installation, Operation and Maintenance Instructions OTC-2 / OTC-3 CENTRIFUGE BOWL ASSEMBLY & DISASSEMBLY ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506 1402 U.S.A. WORLD AUTHORITY

More information

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE Contents 1 Machine Safety Information 3 1.5 Safety Precautions Prior to Operating Machine 6 2 Machine Installation 7

More information

DESCRIPTION FEATURES WARNINGS APPLICATIONS

DESCRIPTION FEATURES WARNINGS APPLICATIONS FEATURES Long mechanical life Single Pole Double Throw Power switching loads to Amp. Wide range of actuators and terminal design High precision with good repeatability High vibration and shock resistance

More information

Operation, Maintenance and Installation Manual

Operation, Maintenance and Installation Manual Manual No. FS-OM1-5 1-16 in. FloodSafe Inflow Preventer Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 CONSTRUCTION...

More information

CEMENT MIXER MODEL NO: CCM134L OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC0514

CEMENT MIXER MODEL NO: CCM134L OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC0514 CEMENT MIXER MODEL NO: CCM134L PART NO: 3400862 OPERATION & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE Cement Mixer. Before attempting to use this product, please

More information

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio 42 Kevlar Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction Manual 1 1. SAFETY

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

60 Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan 60" Tulle PatioTM A Kichler Select ceiling fan cul Certified for Wet Location Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30

More information

LIGHTING CAUTION NEW LISMORE 9 ARM CHANDELIER W 110V

LIGHTING CAUTION NEW LISMORE 9 ARM CHANDELIER W 110V NEW LISMORE 9 ARM CHANDELIER 950 000 3611 W 110V LIGHTING CAUTION Before any work is started,ensure that the electricity supply has been switched off at the main fuse box. Read the instructions carefully

More information

DAGNY. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

DAGNY. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz DAGNY Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 110V~60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews

More information

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION

More information

Installation & Operating Instructions

Installation & Operating Instructions 3WAY TAP Installation & Operating Instructions AQP-TAP-3S Three Way Tap AQP-TAP-3G Three Way Tap SYSTEM Congratulations on your purchase of the Filtered Water Sink Mixer 3 Way Tap AQUAPORT SELECT 3 STEP

More information

CAUTION EXPOSED SHARP OBJECTS INSIDE. HAZARDOUS MOVING PARTS DO NOT OPERATE WITH COVER OPEN. for Block Ice

CAUTION EXPOSED SHARP OBJECTS INSIDE. HAZARDOUS MOVING PARTS DO NOT OPERATE WITH COVER OPEN. for Block Ice for Block Ice Thank you for purchasing our Swan Ice Shaver. Please read the instruction manual before using the machine. WARNING POTENTIAL RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY EXISTS. CHECK

More information

TOOLS AND MATERIALS REQUIRED

TOOLS AND MATERIALS REQUIRED CANARM 5 YEAR LIMITED WARRANTY THANK YOU for purchasing a Canarm product. It is our policy to furnish you with high quality products at a fair price. With proper installation your fan should provide you

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Distinctive Lighting and Ceiling Fans CEILING FAN OWNER'S MANUAL MODEL: 52CW2L5-GM 52CW2L5-OBB READ AND SAVE THESE INSTRUCTIONS FOR CEILING FAN PARTS AND SERVICE, CALL 1-877-902-5588 FAN RATING AC 120V.

More information

Acqua. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS

Acqua. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS Acqua Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz For Damp Location QUICK ASSEMBLY NOTES: * Do not wire in fan while house wires are Live. Turn power off at

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-607(B) Series FS7-4 Industrial Liquid Flow Switch (specified models only) Series FS7-4 OPERATION This control is an independently mounted water

More information

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive) 36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free

More information

INLET DAMPER WALL FAN UNIT

INLET DAMPER WALL FAN UNIT FARM PRODUCTS DIVISION MEMBER OF AMCA AMERICAN COOLAIR CORPORATION P.O. BOX 2300 JACKSONVILLE, FLORIDA 32203 PHONE (904) 389-3646 FAX (904) 387-3449 E-MAIL - agfans@coolair.com INLET DAMPER WALL FAN UNIT

More information

nordica 36 ceiling fan

nordica 36 ceiling fan 09/15 nordica 36 ceiling fan model no. 052-1191-4! INSTRUTIONS PERTAINING TO RISK OF FIRE OR INJURY TO PERSONS. READ ALL INSTRUTIONS IMPORTANT SAFETY INSTRUTIONS SAVE THESE INSTRUTIONS INSTALLATION AND

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL MODEL: Pelham HVFC# 2299 Old Bronze Satin Nickel Polished Nickel READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz. CUL LISTED MODEL: AC-554SY05-7S WEIGHT OF THE FAN:

More information

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent

More information

Drum Carrier. Operating Instructions and Parts Manual 21VG4 8 DESCRIPTION 21VG48. Allows 1 person to lift, transport, tilt, rotate, and drain

Drum Carrier. Operating Instructions and Parts Manual 21VG4 8 DESCRIPTION 21VG48. Allows 1 person to lift, transport, tilt, rotate, and drain Operating Instructions and Parts Manual 2VG4 8 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself

More information

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions FARM PRODUCTS DIVISION MEMBER OF AMCA AMERICAN COOLAIR CORPORATION P.O. BOX 2300 JACKSONVILLE, FLORIDA 32203 PHONE (904) 389-3646 FAX (904) 387-3449 E-MAIL - fans@coolair.com MNEFDD54 & MNBCDD54 GALVANIZED

More information

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan 52 StarkkTM A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday

More information

FieldLink Cable solutions for Automation & Drives

FieldLink Cable solutions for Automation & Drives FieldLink Cable solutions for Automation & Drives The LEONI Group Cable competence for different industrial markets Our group of companies employs more than 64,000 people in 33 countries. Corporate vision,

More information

Wheelbarrow Mixer Operations Manual

Wheelbarrow Mixer Operations Manual Wheelbarrow Mixer Operations Manual Part# MIX3, MIX3-UK EDI# 27275, 27276 104 S. 8th Ave. Marshalltown, IA Phone 800-888-0127 / 641-753-0127 Fax 800-477-6341 / 641-753-6341 www.marshalltown.com 1 of 20

More information

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) Galvanized Panel Fan IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble, install, operate

More information

Tool Chests and Cabinets

Tool Chests and Cabinets Operating Instructions Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings,

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION OPERATION INSTALLATION PARTS MANUAL www.fostoriaindustries.com Made in U.S.A. ELECTRIC PORTABLE HEATER FES-1024-1CA 08860010 YES-1024-1CA 08861510 FES-1520-3A 08860110 YES-1520-3A 08860810 FES-1524-1A

More information

Shredder FD 8906CC Cross-Cut

Shredder FD 8906CC Cross-Cut Shredder FD 8906CC Cross-Cut 1/2017 OPERATOR MANUAL Machine Specs Model: FD 8906CC Motor Power Sheet Capacity Serial #: 7.5KW (10HP) Three-phase, 220V, 50/60 Hz, 50 Amp dedicated line required, CS8365

More information

GL190-A / GL191-A / GJ461-A

GL190-A / GL191-A / GJ461-A Planetary Mixer Instruction manual Model: GL190-A / GL191-A / GJ461-A GL190-A_GL191_A_GJ461-A_A5_v3_170809.indb 1 2017/8/9 17:39 Exploded diagram and spare parts list GL190-A GL190-A_GL191_A_GJ461-A_A5_v3_170809.indb

More information

innovation > technology > future

innovation > technology > future Laundry systems Transaxle Technology provides added support and stability to the gear shaft. This equalizes roller pressure, extending the life of the motor gearbox and squeeze tube. innovation > technology

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL READ AND SAVE THESE INSTRUCTIONS MODEL: 52-135-5WA-13 FAN RATING AC 120V. 60Hz CUL LISTED MODEL : AC-552OD 1. TOOLS AND MATERIALS REQUIRED Philips screw driver Blade screw driver

More information

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 160 854 Roanoke 48 in Ceiling Fan Owner s Manual Roanoke Ventilador de Techo de 1,22 m Manual del Propietario 48 Roanoke Ceiling Fan by Hampton Bay Thank you for purchasing our ceiling fan. This product

More information

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan 60 StarkkTM LED A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday

More information

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

60 Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan Includes our new Wall Control System 60" Hatteras BayTM Patio A Kichler Décor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706

More information

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL Indoor Convective Panel Heater CONTENTS Rev A NOV14 1. Product Overview 2. Specification Data 3. Operations 4. Installation 5. Safety 6. Maintenance

More information

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard.

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard. XC-18 NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard. EXTREMA MACHINERY COMPANY, INC. PO BOX 1450, ALBANY, LOUISIANA

More information

Installation Manual. Models 99168, 99169, 99170

Installation Manual. Models 99168, 99169, 99170 Wet-Rated Globe Fitter Installation Manual Compatible with: 2xxxx Types A - Z 51000-58999 fan series 59500-59999 fan series Select Casablanca Fans Models 99168, 99169, 99170 BEFORE YOU BEGIN Read entire

More information

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250) Worldwide Contacts www.tyco-fire.com Model BFV-/BFV-C Butterfly Grooved End General Description The TYCO Models BFV- (Normally Open) and BFV-C (Normally Closed) Grooved End Butterfly s are indicating type

More information

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310 Condair Esco Steam humidification system L INSTALLATION INSTRUCTIONS 1117775 EN 1310 3 Contents 1 Introduction 4 1.1 General 4 1.2 Safety 4 2 Esco DL40 5 2.1 Overview Esco DL40 5 2.2 Mounting the Esco

More information

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P. 541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner.

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner. Removal 3.7L/4.7L ENGINE CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner. 1. Disconnect negative battery cable from battery. 2. Rotate belt

More information

Austin 42 Ceiling Fan

Austin 42 Ceiling Fan 052-4743-4 10/14 This Noma product carries a limited ten (10) year warranty against defects in the motor, and a one (1) year warranty against defects in workmanship and materials. Trileaf Distribution

More information

Marley Ultra Quiet Fan

Marley Ultra Quiet Fan USER MANUAL Marley Ultra Quiet Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2012-1165 ISSUED 8/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and

More information

Bubble 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS

Bubble 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS Bubble 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz For Damp Location QUICK ASSEMBLY NOTES: * Do not wire in fan while house wires are Live. Turn power off at breaker before

More information