McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

Size: px
Start display at page:

Download "McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018"

Transcription

1 Replacement Parts List No Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... 3 Serial Number Nomenclature... 4 Unit Model Nomenclature... 5 Electrical Legend... 6 Compressor and Condenser Section... 7, 8 Tubing Condenser Fan and Exhaust Fan...12, 13 Supply Air Fan Section Evaporator Coil and Filter...17, 18 Economizer Section...19, 20 Heat Section Cabinet... 25, 26 Controls Control Box Diagram Common Components Disconnect Switch and Power Block Transformers and Fuses Compressor Motor Protectors and Contactors Condenser Fan Motor and Exhaust Constant Air Volume (Code 05= C) Variable Air Volume (Code 05= V) Ground Fault Circuit Interrupter (Code 20= F) Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 2

3 Parts List Revision History Revision Date Description 11/09 New A 01/10 Page 8: Added Ckt 1 & 3 description to 5.7 Hp Compressors. Page 11: Corrected Ref #s, descriptions and part #s for Hot Gas Bypass Clamps & Reducers. Page 22: Corrected Gas Heater information. Page 30: Added Compressor chart & changed quantities from per unit to per compressor. Page 31: Changed 460V M51, M52 from to Changed TB51 from to and quantity from 1 to 3. Pages 32-33: Added part numbers for 2 HP Supply Fan Motor Controls. B 02/11 Various: Corrected Misc. spelling and formatting issues. Page 5: Changed Option E for Code 16 from: E=Coated Evap Coil, Cond Coil & HGRH Coil to: E=Coated Evap Coil, Water Coil & HGRH Coil. Page 8: Changed Low Pressure Switch from to Changed Crankcase Heater, 65W, 120V p/n: to Crankcase Heater, 5.7HP & 7HP Compressor p/n: Added Line: Crankcase Heater 10HP Compressor. p/n: qty. 1pc. for Size 025. Changed qty of 5.7 & 10HP Crankcase heaters for size 025 from 3 to 2. Page 13: Changed Ref# C411, C461, H262, H V motor p/n from to Page 15: Changed D005 Fan Bearing description from Fan Bearing, 1 11/16 to Fan Bearing, 1 7/16. Page 30: Changed header for Compressor HP from 5.7, 7.0 & 7.5 to 5.7, 7.0 & Page 31: Re-arranged and updated Power Exhaust table. MMP51 p/n deleted entry for 460V (575V Only). Added qty of 2 to 460V entry for M51, 52 p/n Changed description of M51, M52 p/n from M51, M52 IEC Contactor 4-6.3A, 600V to MMP51 IEC Manual Starter 4-6.3A, 600V, Push Button. Changed qty. of 2 for 460V entry for p/n to 1. Changed Ref# VFD51 3HP VFD p/n to Page 32: For Ref# M10, 575V Contactor p/n deleted qty of 1 for 3-10HP (15HP motors only). C 12/11 Page 27: Changed SPS1 p/n to & SPS2 p/n to D 03/13 Cover, Rev. pg.: Updated to current logo format. Various: Changed McQuay Parts to Daikin McQuay Parts. Page 15: Changed Ref # D V 2HP motor from : to & 3HP motor from to Page 26: Rewrote footnote. Page 34: F6A, B & C p/ns were reversed. Corrected fuse descriptions. Rewrote footnote. E 11/13 Cover, Rev pg.: Changed to Daikin Applied logo format. Various: Changed McQuay and Daikin McQuay Parts to Daikin Applied. Various: Corrected Misc. formatting issues. Page 4: Corrected serial number nomenclature. Page 8: Added footnote #1 & footnote notation. Page 15: Corrected D240- D270 Spring Isolator p/n descriptions. Page 29: Added Code 03 information to Units w/o Gas Heat. F 04/15 Page 22: Moved Electric Heat table to new pg. 23. Updated Gas Heater p/ns & added dwg./bubble #s. Page 23 (NEW): Added new pg. with Electric Heater p/ns from pg. 22. Repaginated form & updated TOC. G 09/15 Cover: Updated to Daikin Legacy format. Page 8: Updated Cmpr. CC Heater p/ns. Rewrote footnote #1. Page 13: Added table headers. Page 18: Added SS sub. for #E130 Molded Polymer Drain Pan. Page 27: Added Control Box Diagram to pg. header. Updated the TOC. H 11/17 Various: Changed Standard Gas Heat to Staged Gas Heat. Page 5: Misc. updates. Page 6: Reformatted table. Page 13: Updated Condenser & Exhaust Fan Mtr. p/n & added footnote # 1. Page 22: Added footnote # 3. Misc. updates/corrections. Page 23: Added L150 High Limit p/n to table. Rewrote footnote. I 12/17 Various: Misc. formatting fixes. Deleted green box note. Page 17: Updated the dwg. Page 18: Updated/corrected Exp. Vlv. p/ns & descriptions. Page 28: Changed General to Common Components & updated the TOC. Added footnotes. J 02/18 Page 4, 5: Misc. updates. Page 7: Updated the dwg. Page 22: Added Flame Sensor Lead p/n Page 23, 31: Corrected misc. formatting issues. Page 24: Rewrote pg. header. Updated dwg. Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 3

4 Serial Number Nomenclature FBO U Plant Identification FBO = Faribault, MN U = Unit Year of Manufacture 09 = = 2010 etc. Month of Manufacture 01= January 02= February 03= March 04= April 05= May 06= June 07= July 08= August 09= September 10= October 11= November 12= December Serial Number (build sequence) Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 4

5 Unit Model Nomenclature MPS 020E G 4D V 1DY RY DY Y D 07P 1630 FS 024G2 YYYY Y Y Y Y Y Y 04 Code MPS= Daikin Applied Packaged System 02 Unit Size 020E= 20 Ton 025E= 25 Ton 03 Heat G= Natural Gas Heat E= Electric Heat W= Hot Water Heat Y= None 04 Voltage/Power Connection Digit 1 2= 208 Volt Power Supply 3= 230 Volt Power Supply 4= 460 Volt Power Supply 5= 575 Volt Power Supply Digit 2 P= Power Block D= Non-Fused Disconnect Switch 05 Application C= Constant Volume V= Variable Volume 06 OA/Economizer Digit 1 1= 0-100% Economizer 3= 0-30% Outside Air 2-Position Y= None Digit 2 D= Dry Bulb Economizer Control C= Comparative Enthalpy Control E= Enthalpy Control Y= None Digit 3 C= CO2 Override M= OA Monitoring B= CO2 Override & OA Monitoring Y= None 07 Exhaust Digit 1 R= Barometric Relief P= Power Exhaust B= Building Pressure Control w/vfd Y= None Digit 2 V= VFD Control Y= None 08 Controls Digit 1 D= DDC Controls Digit 2 I= BACnet/IP card L= LON card M= BACnet/MSTP card Y= None 09 Coil Section Y= Polymer Drain Pan S= Stainless Steel Drain Pan 10 Cabinet D= Double Wall Construction 11 Supply Fan Motor Digit 1 03= 3 HP 07= 7.5 HP 15= 15 HP 05= 5 HP 10= 10 HP Digit 2 P= Premium Efficiency 12 Supply Fan RPM 13 Drive Type/Fan Isolation Digit 1 F= Fixed Drive Digit 2 S= Spring Isolation 14 Heat Digits = 240 MBH Gas Heat 048= 480 MBH Gas Heat 036= 36 kw Electric Heat 054= 54 kw Electric Heat 072= 72 kw Electric Heat YYY= No Heat Digit 4 G= Aluminized Heat Exchanger-Gas Heat S= Stainless Steel Heat Exchanger-Gas Heat Y= Electric Heat or No Heat Digits 1-4 W141= Low Hot Water Heat W092= High Hot Water Heat Digit 5 2= 2- Stage Gas Heat 4= 4- Stage Gas or Electric Heat M= Modulating Gas Heat Y= No Valve Package on Hot Water Heat 15 Hot Gas Bypass & Hot Gas Reheat Digit 1 H= HGBP (1st circuit) Y= No HGBP Digit 2-4 YYY= None 16 Coil Options B= Coated Evaporator and Condenser Coils C= Coated Condenser Coil E= Coated Evap Coil, Water Coil & HGRH Coil Y= None 17 Low Ambient Control 2= Pressure Type Link Fan Cycling Controls Y= Standard Low Ambient Control 18 Compressor Isolation Valves 1= With Valves Y= None 19 Smoke Detectors 1= RA Smoke Detector Y= None 20 Electrical Options F= Factory Wired GFI Receptacle Y= None 21 Miscellaneous X= Special Y= None 22 Cooling Coil Size 04= 4 Row 06= 6 Row Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 5

6 Electrical Legend ACT3 Actuator Motor, Economizer AHL Auxiliary Hi-Limit Switch, Gas Heat, Manual Reset CB10 Circuit Breaker, Supply Fan CB51 Circuit Breaker, Exhaust Fan CCH1-4 Crankcase Heater DAT Temperature Sensor, Discharge Air DHL Duct Hi-Limit Switch DS1 Disconnect Switch F1A, B Fuse, Control Circuit Transformer (T1), Primary F1C Fuse, Control Circuit Transformer (T1), Secondary HL Hi-Limit Switch, Gas Heat HP1, 2 High Pressure Switch, Circuits 1 & 2 LP1, 2 Low Pressure Switch, Circuits 1 & 2 M1-4 Contactor, Compressors M10 Contactor, Supply Fan M11-13 Contactor, Condenser Fans M51, 52 Contactor, Exhaust Fans MCB Microprocessor Circuit Board MJ Mechanical Jumper MMP1-4 Manual Motor Protector, Compressors MMP10 Manual Motor Protector, Supply Fan MMP11-13 Manual Motor Protector, Condenser Fans MMP51 Motor Protector, Exhaust Fans OAE Enthalpy Sensor, Outside Air OAT Temperature Sensor, Outside Air PB1 Power Block, Power Distribution PC5 Pressure Control, Dirty Filter Switch PC7 Pressure Control, Proof Airflow Switch R_HP1, 2 Relay, High Pressure Switch, Circuits 1 & 2 R_HTR1, 2 Relay, Heater Stages 1 & 2 R_FANOP Relay, Fan Operation R_VFD10 Relay, VFD Enable, Supply Fan R_VFD51 Relay, VFD Enable, Exhaust Fans RAE Enthalpy Sensor, Return Air RAT Temperature Sensor, Return Air REC1 Receptacle, GFCI SPS1 Static Pressure Sensors, Duct SPS2 Static Pressure Sensors, Building T1 Transformer, Main Control (line-115vac) T2 Transformer, Control In/Out (115-24VAC) TB1 Terminal Block, Internal Distribution TB2 Terminal Block, Field TB51 Terminal Block, Exhaust Fan Distribution VFD10 Variable Frequency Drive, Supply Fan VFD51 Variable Frequency Drive, Exhaust Fans Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 6

7 Compressor and Condenser Section C400 C370 C450 C370 C305 C295 C270 C285 C280 C372 C260 C155 C374 (FAR SIDE) C220 C200 (THIS SIDE) C190 C180 C235 C020 C104 C090 C010 C103 C305 C290 C101 C102 C305 C300 C085 C100 Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 7

8 Compressor and Condenser Section Ref. # Description Part Number C010 Single Compressor, 5.7 HP, /3/60 (Ckt. 1 & 3) C010 Single Compressor, 5.7 HP, 460/3/60 (Ckt. 1 & 3) C010 Single Compressor, 5.7 HP, 575/3/60 (Ckt. 1 & 3) C020 Single Compressor, 7 HP, 208/230/3/60 (Ckt. 2) C020 Single Compressor, 7 HP, 460/3/60 (Ckt. 2) C020 Single Compressor, 7 HP, 575/3/60 (Ckt. 2) C020 Single Compressor, 10 HP, /3/60 (Ckt. 2) C020 Single Compressor, 10 HP, 460/3/60 (Ckt. 2) C020 Single Compressor, 10 HP, 575/3/60 (Ckt. 2) Low Pressure Switch High Pressure Switch Crankcase Heater, 5.7 HP & 7 HP Compressors Crankcase Heater, 10 HP Compressor Grommet (Quantity = 8 per compressor sled) Spacer (Quantity = 8 per compressor sled) Screw, x Nut, Flat Washer,.312 nom This SINGLE Compressor is factory mounted in a Tandem Compressor Assembly. Contact Daikin Applied for Tandem Compressor Assembly availability. Ref. # Description Part Number C180, C190 Condenser Coil, 42 x 62 (Code 16= E, Y) C180, C190 Condenser Coil, Coated, 42 x 62 (Code 16= B, C) C290, C295 Condenser Section Guard, Sides, x C300 Condenser Section Guard, Front, x Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 8

9 Tubing Liquid Tubing Discharge Tubing Shown with optional ball valves Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 9

10 Tubing Suction Tubing Shown with optional ball valves Optional Hot Gas Bypass Tubing Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 10

11 Tubing Ref. # Description Part Number T120, T220 Liquid Line Sight Glass,.625 x T120, T220 Liquid Line Filter Drier,.625 ODF R970, R975 Shutoff Ball Valve,.875, Discharge Ckt. 1 & U970 Shutoff Ball Valve, 1.375, Suction Ckt U975 Shutoff Ball Valve, 1.125, Suction Ckt U970, U975 Shutoff Ball Valve, 1.375, Suction Ckt. 1 & Optional Hot Gas Bypass (Code 15= H***) S905 Hot Gas Bypass Grommet S907 Hot Gas Bypass Clamp S916 Hot Gas Bypass Reducer S916 Hot Gas Bypass Reducer S970 Hot Gas Bypass Valve Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 11

12 Condenser Fan and Exhaust Fan H265 H275 C414 C464 Circle Bubbles = Condenser Fan components Hexagon Bubbles = Exhaust Fan components Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 12

13 Condenser Fan and Exhaust Fan Condenser Fan Ref. # Description Part Number C411, C461 Condenser Fan Motor, /460V C411, C461 Condenser Fan Motor, 575V C412, C462 Condenser Fan Prop, 26 dia, C413, C463 Condenser Motor Mount (2 per motor) C414, C464 Condenser Grille, Fan Guard C418, C468 Steel Spacer per motor C930 Grommet,.625 ID per motor C952 Screw, 5/16-18 x per motor C960 Nut, 5/ per motor C970 Washer, Plain, narrow 5/ per motor C971 Washer, Plain, wide 5/ per motor - Screw, Tap #10-32 x.38 hex per motor - Washer, Lock, # per motor - Conduit Fitting,.500 STRT per motor 1 The original motor is obsolete and no longer available. This inverter duty motor is a direct replacement. Exhaust Fan Ref. # Description Part Number H262, H272 Exhaust Fan Motor, /460V H262, H272 Exhaust Fan Motor, 575V H263, H273 Exhaust Fan Prop, 26 dia, H264, H274 Exhaust Motor Mount (2 per motor) H265, H275 Exhaust Grille, Fan Guard H269, H279 Steel Spacer per motor H930 Grommet,.625 ID per motor H952 Screw, 5/16-18 x per motor H960 Nut, 5/ per motor H970 Washer, Plain, narrow 5/ per motor H971 Washer, Plain, wide 5/ per motor - Screw, Tap #10-32 x.38 hex per motor - Washer, Lock, # per motor - Conduit Fitting,.500 STRT per motor 2 The original motor is obsolete and no longer available. This inverter duty motor is a direct replacement. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 13

14 Supply Air Fan Section D100 D120 D192 D140 D193 D160 D005 D012 D130 D270 POSITION D D110 D150 D170 D250 POSITION B D912F D260 POSITION C D240 POSITION A D115 D200 D015 D195 D182 D192 Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 14

15 Supply Air Fan Section Ref. # Description Part Number D005 Fan Wheel, D005 Fan Shaft, 19.0 x D005 Fan Bearing, 1-7/ (Qty.= 2) D012 Supply Fan Motor, ODP, 2 HP, 208/230/460V D012 Supply Fan Motor, ODP, 2 HP, 575V D012 Supply Fan Motor, ODP, 3 HP, 208/230/460V D012 Supply Fan Motor, ODP, 3 HP, 575V D012 Supply Fan Motor, ODP, 5 HP, 208V D012 Supply Fan Motor, ODP, 5 HP, 230/460V D012 Supply Fan Motor, ODP, 5 HP, 575V D012 Supply Fan Motor, ODP, 7.5 HP, 208V D012 Supply Fan Motor, ODP, 7.5 HP, 230/460V D012 Supply Fan Motor, ODP, 7.5 HP, 575V D012 Supply Fan Motor, ODP, 10 HP, 230/460V D012 Supply Fan Motor, ODP, 10 HP, 575V D012 Supply Fan Motor, ODP, 15 HP, 230/460V D012 Supply Fan Motor, ODP, 15 HP, 575V D240 D250 D260 D270 Spring Isolator, Blue, 50 lbs Spring Isolator, Tan, 100 lbs Spring Isolator, Red, 150 lbs Spring Isolator, Black, 200 lbs Spring Isolator, Dark Yellow, 300 lbs Spring Isolator, Yellow, 400 lbs D911 Screw, Spring Isolator Mounting, x D912 Screw, Spring Isolator Mounting, x Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 15

16 Supply Air Fan Section 22 Inch Fan Ref. # D005 Motor Code 12 Motor Motor Fan Fan Belt HP Fan RPM Pulley Bushing Pulley Bushing Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 16

17 Evaporator Coil and Filter Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 17

18 Evaporator Coil and Filter Ref. # Description Part Number E001 Evaporator Coil, 4-Row, 44 x 59.5, Std E001 Evaporator Coil, 4-Row, 44 x 59.5, Coated E001 Evaporator Coil, 4-Row, 44 x 59.5, Std E001 Evaporator Coil, 4-Row, 44 x 59.5, Coated E001 Evaporator Coil, 6-Row, 44 x 59.5, Std E001 Evaporator Coil, 6-Row, 44 x 59.5, Coated E001 Evaporator Coil, 6-Row, 44 x 59.5, Std E001 Evaporator Coil, 6-Row, 44 x 59.5, Coated E130 Drain Pan, Stainless Steel (units built 10/21/09 & later) E130 Drain Pan, Molded Polymer (units built before 10/21/09) E130 Drain Pan, Stainless Steel (Polymer replacement) 2 P E145 Bushing for Polymer Drain Pan CIRCA Expansion Valve, 15 Ton (Circuit 1) CIRCA Expansion Valve/Distributor Assy., 15 Ton (Circuit 1) CIRCB Expansion Valve, 12.5 Ton (Circuit 2) CIRCB Expansion Valve/Distributor Assy., 15 Ton (Circuit 2) F100 Air Filter, 30% Pleated, 24 x 24 x F101 Air Filter, 30% Pleated, 24 x 24 x These Evaporator Coils are replacements for coils used on early models. 2 This is a Stainless Steel replacement kit for the Molded Polymer Drain Pan for units built before 10/21/09. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 18

19 Economizer Section View from inside of unit H 243 Optional Smoke Detector RAT Return Air Temperature Sensor H242 Optional RA Enthalpy Sensor Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 19

20 Economizer Section Ref. # Description Part Number H010 Economizer Damper Assy, 0-100% (Code 06= 1**) H010 Economizer Damper Assy, 0-30% Outside Air (Code 06= 3**) Economizer Actuator, 88 lb-in H020 Backdraft Damper, x H045 Mist Eliminator Filter Kit H250 OAE- Outside Air Enthalpy Control H242 RAE- Return Air Enthalpy Control Optional Smoke Detector (Code 19= 1) H243 Smoke Detector (Ionization), Head and Base Smoke Detector Header (Ionization), Head only Kit includes the following filters: (Qty.1) 24x20x1 and (Qty.4) 24x12x1 Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 20

21 Heat Section Diagrams 2 GAS HEATER OPTION 1 GAS HEATER OPTION HIGH LIMIT SWITCH L155 MOUNTING POSITION NO HEAT OPTION ELECTRIC HEAT OPTION Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 21

22 Heat Section Gas Heat (Code 03= G) FRONT VIEW Ref. # Description Part Number Staged Gas Heat L010 Gas Heater, Aluminized Steel, 240 MBH (Code 14= ***G*) L010 Gas Heater, Stainless Steel, 240 MBH (Code 14= ***S*) L011 Gas Heater, Aluminized Steel, 240 MBH (Code 14= 048G4) L011 Gas Heater, Stainless Steel, 240 MBH (Code 14= 048S4) HTR002 Ignition Control, Direct Spark Ignition HTR005 Switch, Air Pressure Control HTR006 Gas Valve, 2 stage Modulating Gas Heat L010 Gas Heater Modulating, St. Stl., 240 MBH (Code 14= ****M) L011 Gas Heater Staged, Stainless Steel, 240 MBH (Code 14= 048*M) HTR002 Circuit Board, Variable Burner Controller (Mod. Board) HTR005 Switch, Air Pressure Control HTR006 Gas Valve, Modulating All Gas Heat HTR001 Motor, Draft Inducer, 115V, 2 Speed HTR003 Spark Ignitor HTR004 Flame Sensor Lead, Flame Sensor, HTR007 Gasket, Inducer Orifice HTR008 Transformer, 40 VA, Multi tap HTR009 Rollout Switch HTR010 Orifice, Burner (6 per Heater Assy) L150 Auxiliary Limit Switch, Gas Heat L155 High Limit Switch, 7, Gas Heat Heat Drain Pan, 25 x LP Conversion Kit, 240 MBH (Code 14= ****2) K 3 - LP Conversion Kit, 480 MBH (Code 14= ****4) K 3 1 L011 is used only with High Gas Heat (Code 14= 048*4). 2 L011 is used only with High Gas Heat (Code 14= 048*M) AND note that is NOT a Modulating Burner. Use p/ns from the STAGED and/or ALL GAS HEAT lists only. 3 LP Conversion kits are ONLY available for Staged Gas Heat Furnaces (Code 14= ****2 OR ****4). If a conversion from natural gas to propane is desired AND the unit has a Modulating Gas Heat Exchanger (L010), a NEW STAGED Heat Exchanger AND the correct LP Conversion Kit is required. Contact Daikin Applied to identify any additional parts required for the conversion. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 22

23 Heat Section Electric Heat (Code 03= E) Ref. # Description 208V 230V 460V 575V L012 Electric Heat Assy, 36 kw L012 Electric Heat Assy, 54 kw L012 Electric Heat Assy, 72 kw L155 High Limit Switch, Electric Heat Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 23

24 Heat Section Hot Water Heat (Code 03= W) L208 L016 L209 L207 L090 L900 L211 L105 L231 L200 L230 L210 L231 L206 4 L105 L106 L100 L205 Ref. # Description Part Number L200 Low Hot Water Heat Coil (Code 14= W141Y) L200 High Hot Water Heat Coil (Code 14= W092Y) Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 24

25 Cabinet Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 25

26 Cabinet Ref. # Description Part Number M930 Panel Latch Assy M935 Latch Handle, Pulltab Gasket, Fixed Panel, Z-Channel,.125 x Gasket, Door,.50 x Hinge, 2 x Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 26

27 Controls Control Box Diagram 1 MMP10 MMP51 M51 M52 M10 1 This diagram is representative of a typical control box layout. Not all possible Control Box configurations are shown above as components and component layout vary depending upon unit options selected. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 27

28 Controls Common Components Ref. # Description Part Number MCB PC Board, Medium , 2 Terminal Kit for Medium Controller MCB PC Board, Large Terminal Kit for Large Controller PCO3 Smart Key, Programmable PC Board, IP/Ethernet Communication Module MS/TP Communication Module LON SCC Communication Module SPS1 Pressure Transducer SPS2 Pressure Transducer RAT Temp sensor, Return Air, 20 ft DAT Temp sensor, Discharge Air, 20 ft OAT Temp sensor, Outside Air, 20 ft PC5 Switch, Dirty Filter PC7 Switch, Proof of Airflow DHL Switch, Duct High Limit R_FANOP Relay, Ice Cube, SPDT, 120VAC, 15A R_HP1 Relay, Ice Cube, SPDT, 120VAC, 15A R_HP2 Relay, Ice Cube, SPDT, 120VAC, 15A R_HTR1 Relay, Ice Cube, SPDT, 120VAC, 15A R_HTR2 Relay, Ice Cube, SPDT, 120VAC, 15A R_VFD10 Relay, Ice Cube, SPDT, 120VAC, 15A R_VFD51 Relay, Ice Cube, SPDT, 120VAC, 15A REC1 Receptacle, Ground Fault, 15A, 120V CO2 Duct Sensor CO2 Space Sensor, Wall Mount Space Sensor w/tenant Override, Wall Mount Space Sensor w/ Tenant Override and Setpoint Adjustment, Wall Mount The Main Control Board must be programmed in order to function correctly. When ordering a replacement MCB, provide the unit model and serial number so the unit specific software code can be loaded before shipment. 2 This controller is obsolete with limited availability. Check for availability BEFORE ordering. Use as a substitute. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 28

29 Controls Disconnect Switch and Power Block Ref. Description Part Number Disconnect Switch 1 (Code 04= *D) DS1 Circuit Breaker Kit, 100A (includes Switch, Mechanism and Handle) Circuit Breaker, 100A, Molded Case Switch Flange Mounted Operating Mechanism and Handle Disconnect Shaft GFI Lug Kit (Code 20= F) Load Lugs, 6-position DS1 Circuit Breaker Kit, 150A (includes Switch, Mechanism and Handle) Circuit Breaker, 150A, Molded Case Switch Flange Mounted Operating Mechanism Flange Mounted Handle Disconnect Shaft GFI Lug Kit (Code 20= F) Load Lugs, 6-position DS1 Circuit Breaker Kit, 250A (includes Switch, Mechanism and Handle) Circuit Breaker, 250A, Molded Case Switch Flange Mounted Operating Mechanism Flange Mounted Handle Disconnect Shaft GFI Lug Kit (Code 20= F) Load Lugs, 6-position DS1 Circuit Breaker Kit, 400A (includes Switch, Mechanism and Handle) Circuit Breaker, 400A, Molded Case Switch Flange Mounted Operating Mechanism and Handle Disconnect Shaft GFI Lug Kit (Code 20= F) GFI Connector (Code 20= F) Load Lugs, 12-position Power Block 2 (Code 04= *P) PB1 Power Terminal Block, 175A, 3P, 2 x 12, 600V (Code 03= G, Y) PB1 Power Terminal Block, 175A, 3P, 2 x 12, 600V (Code 03= E) PB1 Power Terminal Block, 350A, 3P, 2 x 6, 600V PB1 Power Terminal Block, 420A, 3P, 1 x 8, 600V PB1 Power Terminal Block, 510A, 3P, 2 x 12, 600V This list includes the most common Disconnects offered. Due to the various unit options available, before ordering it is necessary to confirm what amperage Circuit Breaker is installed in the unit, or if this is not known, contact Daikin Applied with model and serial number information to ensure that the correct part(s) are ordered. 2 This list includes the most common Power Blocks offered. Due to the various unit options available, before ordering it is necessary to confirm what amperage Power Block is installed in the unit, or if this is not known, contact Daikin Applied with model and serial number information to ensure that the correct part is ordered. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 29

30 Controls Transformers and Fuses Ref. # Description Part Number 208V 230V 460V 575V Unit without Gas Heat (Code 03= Y, W, E) T1 Transformer V, 300VA T1 Transformer, 230/ V, 300VA T1 Transformer, V, 300VA F1A, B Fuse, 7A, Rejection Type, 600V F1A, B Fuse, 6A, Rejection Type, 600V F1A, B Fuse, 3A, Rejection Type, 600V F1A, B Fuse, 2A, Rejection Type, 600V F1C Fuse, 4A, Midget, Non-Rejection Type 120V Units with Low Gas Heat (Code 14= 024**) T1 Transformer, V, 500VA T1 Transformer, 230/ V, 500VA T1 Transformer, V, 500VA F1A, B Fuse, 6A, Rejection Type, 600V F1A, B Fuse, 5A, Rejection Type, 600V F1A, B Fuse, 4A, Rejection Type, 600V F1C Fuse, 6A, Midget, Non-Rejection Type, 120V Units with High Gas Heat (Code 14= 048**) T1 Transformer, V, 750VA T1 Transformer, 230/ V, 750VA T1 Transformer, V, 750VA F1A, B Fuse, 9A, Rejection Type, 600V F1A, B Fuse, 8A, Rejection Type, 600V F1A, B Fuse, 6A, Rejection Type, 600V F1C Fuse, 10A, Midget, Non-Rejection Type, 120V All Units T2 Transformer, V, 75VA Fuse Puller Kit for T Finger-Safe Cover Kit Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 30

31 Controls Compressor Motor Protectors and Contactors Unit size Compressor HP Compressor HP Compressor HP Circuit 1 Circuit 2 Circuit HP 7.0 HP 5.7 HP HP 10.0 HP 5.7 HP Ref. # Description Part Number (Qty. per Compr.) Compressor HP V MMP1-3 IEC Manual Starter 17-23A, 600V, Push Button MMP1-3 IEC Manual Starter 20-25A, 600V, Push Button MMP1-3 IEC Manual Starter 25-40A, 600V, Push Button M1-3 IEC Contactor 25-32A, 600V M1-3 IEC Contactor 40-50A, 600V Link, Contactor to MMP V MMP1-3 IEC Manual Starter 17-23A, 600V, Push Button MMP1-3 IEC Manual Starter 25-40A, 600V, Push Button M1-3 IEC Contactor 25-32A, 600V M1-3 IEC Contactor 40-50A, 600V Link, Contactor to MMP V MMP1-3 IEC Manual Starter 9-14A, 600V, Push Button MMP1-3 IEC Manual Starter 17-23A, 600V, Push Button M1-3 IEC Contactor 12-18A, 600V M1-3 IEC Contactor 18-25A, 600V M1-3 IEC Contactor, 25-32A, 600V Link, Contactor to MMP V MMP1-3 IEC Manual Starter 6-10A, 600V, Push Button MMP1-3 IEC Manual Starter 9-14A, 600V, Push Button MMP1-3 IEC Manual Starter 13-18A, 600V, Push Button M1-3 IEC Contactor 12-18A, 600V M1-3 IEC Contactor 25-32A, 600V Link, Contactor to MMP Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 31

32 Controls Condenser Fan Motor and Exhaust Fan Motor Ref. # Description Part Number 208V 230V 460V 575V Condenser Fan Motor Protector MMP11 IEC Manual Starter 9-14A, 600V, Push Button MMP11 IEC Manual Starter 6-10A, 600V, Push Button MMP11 IEC Manual Starter 4-6.3A, 600V, Push Button MMP11 IEC Manual Starter, 2.5-4A, 600V, Push Button M11, M12 IEC Contactor 0-9A, 600V NS Bus Bar, Fan Contactor as needed Ref. # Description Part Number 208V 230V 460V 575V Power Exhaust (Code 07= P*) MMP51 IEC Manual Starter 6-10A, 600V, Push Button MMP51 IEC Manual Starter 4-6.3A, 600V, Push Button MMP51 IEC Manual Starter 2.5-4A, 600V, Push Button M51, M52 IEC Contactor 0-9A, 600V Building Pressure Control with VFD (Code 07= BV) MMP51 IEC Manual Starter 6-10A, 600V, Rotary CB51 Circuit Breaker, 480V, 15A CB51 Circuit Breaker, 600V, 15A VFD51 VFD, 3 HP, 208/230V VFD51 VFD, 3 HP, 460V VFD51 VFD, 3 HP, 575V LR51 Line Reactor, 5%, 575V, 3 HP TB51 Terminal Block Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 32

33 Controls Constant Air Volume (Code 05= C) Ref. # Description Part Number Supply Fan Motor HP V MMP10 IEC Manual Starter 4-6.3A, 600V Push Button MMP10 IEC Manual Starter 6-10A, 600V Push Button MMP10 IEC Manual Starter 13-18A, 600V Push Button MMP10 IEC Manual Starter 17-23A, 600V Push Button MMP10 IEC Manual Starter 24-32A, 600V Push Button MMP10 IEC Manual Starter 25-40A, 600V Push Button M10 IEC Contactor 0-9A, 600V M10 IEC Contactor 9-12A, 600V M10 IEC Contactor 18-25A, 600V M10 IEC Contactor 25-32A, 600V M10 IEC Contactor 40-50A, 600V V MMP10 IEC Manual Starter 4-6.3A, 600V Push Button MMP10 IEC Manual Starter 6-10A, 600V Push Button MMP10 IEC Manual Starter 9-14A, 600V Push Button MMP10 IEC Manual Starter 17-23A, 600V Push Button MMP10 IEC Manual Starter 20-25A, 600V Push Button MMP10 IEC Manual Starter 25-40A, 600V Push Button M10 IEC Contactor 0-9A, 600V M10 IEC Contactor 9-12A, 600V M10 IEC Contactor 12-18A, 600V M10 IEC Contactor 18-25A, 600V M10 IEC Contactor 25-32A, 600V M10 IEC Contactor 32-40A, 600V V MMP10 IEC Manual Starter 2.5-4A, 600V Push Button MMP10 IEC Manual Starter 6-10A, 600V Push Button MMP10 IEC Manual Starter 9-14A, 600V Push Button MMP10 IEC Manual Starter 13-18A, 600V Push Button M10 IEC Contactor 0-9A, 600V M10 IEC Contactor 9-12A, 600V M10 IEC Contactor 12-18A, 600V M10 IEC Contactor 18-25A, 600V V MMP10 IEC Manual Starter A, 600V Push Button MMP10 IEC Manual Starter 2.5-4A, 600V Push Button MMP10 IEC Manual Starter 4-6.3A, 600V Push Button MMP10 IEC Manaul Starter 6-10A, 600V Push Button MMP10 IEC Manual Starter 13-18A, 600V Push Button M10 IEC Contactor 0-9A, 600V M10 IEC Contactor 9-12A, 600V M10 IEC Contactor 12-18A, 600V M10 IEC Contactor 18-25A, 600V Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 33

34 Controls Variable Air Volume (Code 05= V) Ref. # Description Part Number Supply Fan Motor HP V MMP10 IEC Manual Starter 4-6.3A, 600V Rotary MMP10 IEC Manual Starter 6-10A, 600V Rotary MMP10 IEC Manual Starter 13-18A, 600V Rotary MMP10 IEC Manual Starter 17-23A, 600V Rotary MMP10 IEC Manual Starter 24-32A, 600V Rotary CB10 Circuit Breaker, 480V, 50A VFD10 VFD, 2 HP, 208/230V VFD10 VFD, 3 HP, 208/230V VFD10 VFD, 5 HP, 208/230V VFD10 VFD, 7.5 HP, 280/230V VFD10 VFD,10 HP, 208/230V VFD10 VFD, 15 HP, 208/230V V MMP10 IEC Manual Starter 4-6.3A, 600V Rotary MMP10 IEC Manual Starter 6-10A, 600V Rotary MMP10 IEC Manual Starter 9-14A, 600V Rotary MMP10 IEC Manual Starter 17-23A, 600V Rotary MMP10 IEC Manual Starter 20-25A, 600V Rotary CB10 Circuit Breaker, 480V, 50A VFD10 VFD, 2 HP, 208/230V VFD10 VFD, 3 HP, 208/230V VFD10 VFD, 4 HP, 208/230V VFD10 VFD, 7.5 HP, 280/230V VFD10 VFD,10 HP, 208/230V VFD10 VFD, 15 HP, 208/230V V CB10 Circuit Breaker, 480V, 15A CB10 Circuit Breaker, 480V, 20A CB10 Circuit Breaker, 480V, 30A VFD10 VFD, 3 HP, 460V VFD10 VFD, 4 HP, 460V VFD10 VFD, 7.5 HP, 460V VFD10 VFD,10 HP, 460V VFD10 VFD, 15 HP, 460V V CB10 Circuit Breaker, 600V, 15A CB10 Circuit Breaker, 600V, 20A VFD10 VFD, 2 HP, 575V VFD10 VFD, 3 HP, 575V VFD10 VFD, 5 HP, 575V VFD10 VFD, 7.5 HP, 575V VFD10 VFD,10 HP, 575V VFD10 VFD, 15 HP, 575V LR10 Line Reactor, 5%, 575V, 3 HP LR10 Line Reactor, 5%, 575V, 3 HP LR10 Line Reactor, 5%, 575V, 5 HP LR10 Line Reactor, 5%, 575V, 7.5 HP LR10 Line Reactor, 5%, 575V, 10 HP LR10 Line Reactor, 5%, 575V, 15 HP Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 34

35 Controls Ground Fault Circuit Interrupter (Code 20= F) Description Part Number 208V GFCI Panel Assembly Assy. includes: DS6- Switch, 30A, 600 VAC F6A, B- Fuse, 20A, Rejection T6- Transformer, 2000VA, 208>120V F6C- Fuse, 20A, Non-Rejection Midget V GFCI Panel Assembly Assy. includes: DS6- Switch, 30A, 600 VAC F6A, B- Fuse, 20A, Rejection T6- Transformer, 2000VA, 230/460>120V F6C- Fuse, 20A, Non-Rejection Midget V GFCI Panel Assembly Assy. includes: DS6- Switch, 30A, 600 VAC F6A, B- Fuse, 10A, Rejection T6- Transformer, 2000VA, 230/460> F6C- Fuse, 20A, Non-Rejection Midget V GFCI Panel Assembly Assy. includes: DS6- Switch, 30A, 600 VAC F6A, B- Fuse, 8A, Rejection T6- Transformer, 2000VA, 575>120V F6C- Fuse, 20A, Non-Rejection Midget Components listed are replacements for a factory installed unit powered GFCI. If planning to ADD this option in the field, contact Daikin Applied with the unit GO and Serial Number to identify any additional parts that may be required. Maverick II Rooftop, MPS , Vintage E Rev. J 02/18 RPL / Page 35

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018 Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-(

More information

Air Cooled Scroll Compressor Condensing Unit

Air Cooled Scroll Compressor Condensing Unit Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature

More information

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016 Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000 Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787

More information

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998 Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,

More information

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016 Replacement Parts List No. 7000900 Revision E 04/06 McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage A To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015 Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988 Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017 Replacement Parts List No. 7000800 Revision F /07 Daikin McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage B To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4) Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993 Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call

More information

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier eplacement Parts List No. 000000 evision F 09/06 McQuay oofpak Condensing Unit Medium Cabinet, Standalone CS 050-05 Tons Vintage C Code = A, A Valid f units built 06/00 & Earlier To find your Daikin Applied

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993 Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,

More information

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012 Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018 Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017 Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A Replacement Parts List No. 700014100 Revision P 05/2017 Daikin McQuay Pathfinder Air Cooled Chiller Screw Compressor Two Circuit AWS 150-405 Vintage A For units built after 8/1/11, contact Daikin Applied

More information

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994 Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017 Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018 Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

Daikin Daikin McQuay. Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit. AWS Vintage: C Unit Revision 00 (Code 62)

Daikin Daikin McQuay. Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit. AWS Vintage: C Unit Revision 00 (Code 62) Replacement Parts List No. 700028200 Revision J 10/2018 Daikin Daikin McQuay Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit AWS 170-410 Vintage: C Unit Revision 00 (Code 62) To find your Daikin

More information

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2) Replacement Parts List No. 057117200 Revision G 08/2016 McQuay Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E WCDD, WCDE, WCMG 019-060 Design A (1) WCDD, WCDE 019-060 Design B (2) To find

More information

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62) Replacement Parts List No. 700026200 Revision E 05/2017 Daikin McQuay Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit AWS 400-550 Vintage B Unit Revision 0B (Code 62) To find your Daikin Applied

More information

RP8.1Y (ERRATA 1) (202) 2 of 8

RP8.1Y (ERRATA 1) (202) 2 of 8 530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)

More information

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007 Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied

More information

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017 Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017 Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018 Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET DS-07 COMPRESSORS 1 1 Compressor, H20J403DBLA 015-03652-001 2 - - 1 1 Compressor, H20J403DBEA 015-03682-001-2 - 1 1 Compressor,

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET Note: This is a non-comprehensive parts list intended for stocking purposes for first production (style A) units based on current

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Daikin McQuay. Roofpak Evaporative Condensing Units. RPE, RDE Tons Vintage C. Replacement Parts List No Revision K 07/2016

Daikin McQuay. Roofpak Evaporative Condensing Units. RPE, RDE Tons Vintage C. Replacement Parts List No Revision K 07/2016 Replacement Parts List No. 70009400 Revision K 07/06 Daikin McQuay Roofpak Evaporative Condensing Units RPE, RDE 076-50 Tons Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

48 50 UH UA PACKAGED ROOFTOP

48 50 UH UA PACKAGED ROOFTOP 48 50 UH UA PACKAGED ROOFTOP SPARE PARTS GENERAL VIEW FIGURE.1 50 UH-UA 045 FIGURE.2 48-50 UH 045 1 Suction and discharge line piping 2 Liquid line piping 3 Heaters 4 Outdoor fan assembly 5 Indoor fan

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008 Replacement Parts List No. 055237900 Revision R 12/2017 McQuay Seasonmaker ThinLine Horizontal Fan Coil TSH, TSC 031-121 Vintage F FTSH, FTSC 03-12 Designs A(1), B(2) Last Manufactured: 2008 To find your

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Installation and Maintenance Manual IM 988-1

Installation and Maintenance Manual IM 988-1 Installation and Maintenance Manual IM 988-1 Self-Contained Air Conditioning Systems Model SWT C Vintage Sizes 18 through 40 MicroTech III Unit Controller R-407C Refrigerant Group: Applied Air Systems

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

MEA. Self-contained Air Conditioning System. Installation and Maintenance. Type SWT C Vintage Sizes 18 thru 40. Group: Applied Systems

MEA. Self-contained Air Conditioning System. Installation and Maintenance. Type SWT C Vintage Sizes 18 thru 40. Group: Applied Systems Installation and Maintenance IM-709 Group: Applied Systems Part Number: IM709 Date: January 2002 Self-contained Air Conditioning System Type SWT C Vintage Sizes 18 thru 40 MEA 368-93-E 2002 McQuay International

More information

Roof Top Packaged Unit (RTU-1) Specification

Roof Top Packaged Unit (RTU-1) Specification Roof Top Packaged Unit (RTU-1) Specification Item Tag(s) Qty Description Model Number A2 10 Ton 1 10 Ton R410A PKGD Unitary Gas/Electric TRANE: YHC120F3RLA--07C1 Product Data - 10 Ton R410A PKGD Unitary

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

Effective october 14, 2014

Effective october 14, 2014 COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

Daikin Navigator. Water-Cooled Screw Compressor Chiller. WWV JNNS, MNNS, RNNS Vintage A. Replacement Parts List No Revision A 02/2018

Daikin Navigator. Water-Cooled Screw Compressor Chiller. WWV JNNS, MNNS, RNNS Vintage A. Replacement Parts List No Revision A 02/2018 Replacement Parts List No. 700053400 Revision A 02/2018 Daikin Navigator Water-Cooled Screw Compressor Chiller WWV JNNS, MNNS, RNNS Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions 09AZ091-182 Remote Air-Cooled Condensers 90 to 200 Tons Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS.....................1,2 GENERAL........................................

More information

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982 Replacement s List No. 055202900 Revision A 11/1999 Climate Control Singer Incremental Comfort Systems KS, EKS 07-15 Vintage B Last Manufactured: 1982 To find your Daikin Applied parts distributor, call

More information

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for SUBMITTAL DATA for STOCK ROOFTOP UNIT AS ORDERED - PLEASE CHECK AND SIGN AS APPROVED Prepared for Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV 6301 Customer PO#: 38 Prepared by Mason and

More information

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons Product Data 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial

More information

Drying Tumblers Stacked 30 Pound Capacity

Drying Tumblers Stacked 30 Pound Capacity Drying Tumblers Stacked 30 Pound Capacity Models Through Serial No. DTCK9401011756 Refer to Page 3 for Model Numbers Parts www.alliancelaundry.com Part No. M411988R6 November 2012 Table of Contents Title

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

ML-758 Parts Manual. Phase 7 / Non-Coin / Dual Timer with F.S.S. Options

ML-758 Parts Manual. Phase 7 / Non-Coin / Dual Timer with F.S.S. Options ML-758 Parts Manual Phase 7 / Non-Coin / Dual Timer with F.S.S. Options American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com

More information

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC) Point Map December 1, 2004 Systems Integration McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC) Table 1. Microtech II Self-contained Unit Controller

More information

Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel

Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel Product Data 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information