FAST-STAT. Wiring Extenders

Size: px
Start display at page:

Download "FAST-STAT. Wiring Extenders"

Transcription

1 FAST-STAT Wiring Extenders

2 Contents General Information... 2 Basics 3 Model Wiring Diagrams... 6 How to Test.. 12 Model Wiring Diagrams How to Test.. 20 Model Wiring Diagrams.. 23 How to Test. 25 Model Wiring Diagrams How to Test.. 31 Model Wiring Diagrams 34 How to Test.. 37 Common Maker. 38 General Wiring Diagrams 40 Taco Zone Valve & Controller Diagrams.. 43 Fenwal, Weil-Mclain, Energy Kinetics Diagrams. 49 How to Test.. 52 Jan 2017 Edition Note: We reserve the right to make changes & corrections without notice. Every effort has been made to provide accurate technical & product information. The company disclaims responsibility for any error or omission regarding technical & product information published. Nordic Technology Ltd Tel: Fax: Website: info@fast-stat.com 1

3 General Information FAST-STAT wiring extenders electronically add more wires to a control cable. Saves significant time and expense as compared to repulling of new cables. Causes no damage to walls or ceilings as compared to access holes that are often needed when re-pulling cables. The Sender and Receiver communicate over the existing thermostat cable and/or outdoor unit cable. Not a wireless system and therefore avoids all the problems that wireless systems may have. No batteries required. All FAST-STAT models are powered by the existing 24 volt transformer. Compatible with all conventional wiring systems using R, C, W, W2, Y, Y2, G, O/B and other terminals. Works with old and new systems. Can be connected to older systems such as thermopile millivolt, standing pilot systems, intermittent pilot controllers, fan centers etc. Can be used with oil burners, zone controllers and other systems that require dry contact switching. Works over long cable lengths up to 500 ft and more. FAST-STAT Wiring Extenders do not produce interference with other electronic devices nor are they affected electronic devices that produce large amounts of interference. Many FAST-STAT Wiring Extenders can be used in the same building or complex without interference between units. Low power use. Most FAST-STAT models use less than 3 watts of power. 2

4 Basics Models 1000, 3000 & 5000 These are general purpose wiring extender kits that can be used for a wide range of applications. The FAST-STAT Models 1000, 3000 & 5000 come with a Sender and a Receiver. When adding wires from the thermostat to the indoor unit, the Sender is installed into the wall cavity behind the thermostat. This is achieved by increasing the size of the opening around the thermostat cable so that the Sender can be inserted into the wall cavity after the connections to the cable and thermostat are made. The Receiver is installed at the indoor unit near the other controls. If there is no room to mount the receiver inside the cabinet, it can be mounted in any suitable location on or near the indoor unit. When using the Models 1000, 3000 & 5000 to add wires from the indoor unit to the outdoor unit, the Receiver is installed inside the cabinet of the outdoor unit. The Sender is installed at the indoor unit. Models 7000 & 9000 The Model 7000 & 9000 are for air conditioner to heat pump conversions. The Model 7000 is a 3-part kit with a Sender, Indoor Unit Module and an Outdoor Unit Module. This kit requires a minimum of existing 4-wire thermostat cable and a 2-wire outdoor unit cable. The Model 9000 extends the wiring only from the indoor unit to the outdoor unit. It is a 2-part kit with an Indoor Unit Module and an Outdoor Unit Module. The Model 9000 requires a minimum of a 2-wire cable. Common Maker The Common Maker provides a C or common connection for Wi-Fi and other types of powered thermostats. It requires a minimum of a 2-wire thermostat cable. The Common Maker can be used with all types of heating and cooling systems including some types of oil burners and zone controllers that require dry contact switching. Some types of Wi-Fi thermostats require a common connection C in order to function at all while the performance of some types of power stealing battery equipped Wi-Fi thermostats can be greatly improved if they have a common connection. 3

5 Model 1000 Model 1000 It adds one wire to any system The Sender has three wires; Input A, Input B and a communication wire The Receiver has five wires; Output A, Output B, a Communication wire, Power R and a Common C Any combination of two functions such as W1, W2, Y1, Y2, G, O/B and others can be connected. Only transformer R and C cannot be connected to the Sender. 4

6 Model 1000 How It Works Input A and Input B are independent of each other in that either one can be on by itself or they can both be on at the same time. Any two functions such as W, Y, G, or O/B can share one wire between the thermostat and indoor unit or between the indoor and outdoor units. Application Examples 2-stage Air Conditioners A 2-wire air conditioner cable can be converted to provide R, C, Y1 & Y2 using the Model There are two wiring methods that can be used. Wi-Fi Thermostats If the thermostat cable has three or more wires, the Model 1000 can be used to add a common or C connection at the thermostat. This is achieved by having two existing functions share one wire which then frees up a wire that can then become a common wire. Many Wi-Fi thermostats have a self-configure option in which the thermostat automatically detects the wires connected to it in order to make easier for homeowners to install the thermostat. When using the Model 1000, do a Reset then select Pro Setup to manually configure the thermostat. There are diodes in the Model 1000 sender that often prevents the thermostat from properly autoconfiguring itself. Adding an Extra Function The Model 1000 can be used to add W2, Y2, G, etc to a thermostat cable. For example the existing W wire can become W1 & W2. Cable Repairs If a wire in a cable is broken (open circuit) or shorted to another wire or to ground, the Model 1000 can often be used to replace the damaged wire. 5

7 6

8 7

9 8

10 9

11 10

12 11

13 Model 1000 Testing Method 1. Measure the transformer voltage (often marked as R and C). The meter should read from 24 to 28 volts AC. For furnaces, make sure the door switch is in the on position. 2. Connect the Sender directly to the Receiver: PURPLE to PURPLE, and then connect the Receiver BLACK to transformer C, RED to transformer R. 3. Connect the Sender GREEN to the transformer R. The relay in the Receiver should switch on. With Sender GREEN still connected to the transformer R, measure the voltage between the Receiver GREEN wire and the transformer C. The meter should read 24 to 28 volts. 4. Connect the Sender YELLOW to the transformer R. The relay in the Receiver should switch on. With Sender YELLOW still connected to the transformer R, measure the voltage between the Receiver YELLOW wire and the transformer C. The meter should read 24 to 28 volts. 12

14 Model 3000 Model 3000 It adds two wires to a cable. For example, with a 2-wire cable, it can provide R, G, Y, W connections at a thermostat and indoor unit. With cables having more than two wires, the additional wires can be directly connected to the thermostat and indoor unit and used for any purpose. The Sender has six wires; Power In R, Power Out R, a Communication wire, Input A, Input B and Input C. The Receiver has seven wires; Power In R, Power Out R, a Communication wire, Output A, Output B, Output C and a Common C wire. 13

15 Model 3000 How It Works Output A (GREEN wire) and output B (YELLOW wire) are linked so that when output B is on it will also switch on output A. For typical installations output A (GREEN wire) is used for G and output B (YELLOW wire) is used for Y so does not create any problems as the fan will be on with the when the air conditioner is running. Output C (WHITE wire) is independent of outputs A & B. It can be on by itself or at the same time as either or both outputs A or B. It is often used for the W function but can be used for other functions as well. Application Examples Adding Air Conditioning A 2-wire thermostat cable can be converted to provide R, G, Y & W using the Model Wi-Fi Thermostats If the thermostat cable has three or more wires, the Model 3000 can be used to add a common or C connection at the thermostat. This is achieved by having two or three existing functions share one wire which then frees up a wire that can then become a common wire. Many Wi-Fi thermostats have a self-configure option in which the thermostat automatically detects the wires connected to it in order to make easier for homeowners to install the thermostat. When using the Model 3000, do a Reset then select Pro Setup to manually configure the thermostat. There are diodes in the Model 3000 sender that often prevents the thermostat from properly autoconfiguring itself. Adding an Extra Functions The Model 3000 can be used to add W2, Y2, G, etc to a thermostat cable. For example the existing W wire can become W1, W2 & Y2. Cable Repairs If a wire in a cable is broken (open circuit) or shorted to another wire or to ground, the Model 3000 can often be used to replace up to two damaged wires. 14

16 15

17 16

18 17

19 18

20 19

21 Model 3000 Testing Method 1. Measure the transformer voltage (often marked as R and C). The meter should read from 24 to 28 volts AC. For furnaces, make sure the door switch is in the on position. 2. Connect the Sender directly to the Receiver: PURPLE to PURPLE & RED to RED and then connect the Receiver BLACK to transformer C, RED to transformer R. 3. Connect the Sender GREEN to the RED. The relay in the Receiver should switch on. With Sender GREEN still connected to the RED, measure the voltage between the Receiver GREEN wire and the transformer C. The meter should read 24 to 28 volts. 4. Connect the Sender YELLOW to the RED. The relays in the Receiver should switch on. With Sender YELLOW still connected to the transformer R, measure the voltage between the Receiver YELLOW wire and the transformer C. The meter should read 24 to 28 volts. 5. Connect the Sender WHITE to the RED. The relay in the Receiver should switch on. With Sender WHITE still connected to the RED, measure the voltage between the Receiver WHITE wire and the transformer C. The meter should read 24 to 28 volts. 20

22 Model 5000 Model 5000 It adds four wires to a cable. For example, with a 2-wire cable, it can provide R, C, G, Y, W1 & W2 connections at a thermostat and indoor unit. With cables having more than two wires, the additional wires can be directly connected to the thermostat and indoor unit and used for any purpose. The Sender has eight wires; Power In R, Power Out R, a Communication wire, a Common wire, Input A, Input B, Input C & Input D. The Receiver has eight wires; Power In R, Power Out R, a Communication wire, Output A, Output B, Output C, Output D and a Common C wire. 21

23 Model 5000 How It Works Output A (GREEN wire) and output B (YELLOW wire) are linked so that when output B is on it will also switch on output A. For typical installations output A (GREEN wire) is used for G and output B (YELLOW wire) is used for Y so does not create any problems as the fan will be on with the when the air conditioner is running. Output C (WHITE wire) and output D (BLUE wire) are linked so that when output D is on it will also switch on output C. For typical installations output C (WHITE wire) is used for W1 and output D (BLUE wire) is used for W2 so does not create any problems as heat stage-1 will be on when heat stage-2 is on. When output C or output D is on, outputs A and B will shut off. If the fan is in manual on mode it will shut off the fan while the heat exchanger warms up and the furnace fan control/limit then switches on the fan. When the thermostat is in fan manual on mode, at the end of a heating cycle, the fan will continue to operate. Application Examples Adding Air Conditioning A 2-wire thermostat cable can be converted to provide R, C, G, Y, W1 & W2 using the Model Wi-Fi Thermostats The Model 5000 can be used to add a common or C connection at the thermostat. Many Wi-Fi thermostats have a self-configure option in which the thermostat automatically detects the wires connected to it in order to make easier for homeowners to install the thermostat. When using the Model 5000, do a Reset then select Pro Setup to manually configure the thermostat. There are diodes in the Model 5000 sender that often prevents the thermostat from properly autoconfiguring itself. Adding an Extra Functions The Model 5000 can be used to add W2, Y2, G, etc to a thermostat cable. For example the existing W wire can become W1, W2, G & Y. Cable Repairs If a wire in a cable is broken (open circuit) or shorted to another wire or to ground, the Model 5000 can often be used to replace up to five damaged wires. 22

24 23

25 24

26 Model 5000 Testing Method 6. Measure the transformer voltage (often marked as R and C). The meter should read from 24 to 28 volts AC. For furnaces, make sure the door switch is in the on position. 7. Connect the Sender directly to the Receiver: PURPLE to PURPLE & RED to RED and then connect the Receiver BLACK to transformer C, RED to transformer R. 8. Connect the Sender GREEN to the RED. The relay in the Receiver should switch on. With Sender GREEN still connected to the RED, measure the voltage between the Receiver GREEN wire and the transformer C. The meter should read 24 to 28 volts. 9. Connect the Sender GREEN & YELLOW to the RED. The relays in the Receiver should switch on. With Sender GREEN & YELLOW still connected to the transformer R, measure the voltage between the Receiver YELLOW wire and the transformer C. The meter should read 24 to 28 volts. 10. Connect the Sender WHITE to the RED. The relay in the Receiver should switch on. With Sender WHITE still connected to the RED, measure the voltage between the Receiver WHITE wire and the transformer C. The meter should read 24 to 28 volts. 11. Connect the Sender WHITE & BLUE to the RED. The relay in the Receiver should switch on. With Sender WHITE & BLYE still connected to the RED, measure the voltage between the Receiver BLUE wire and the transformer C. The meter should read 24 to 28 volts. 25

27 Model 7000 Model 7000 The Model 7000 is used for air conditioner to heat pump conversions. It requires a minimum of a 4-thermostat cable and a 2-wire heat pump cable. It can operate single or 2-stage heat pumps. The Sender is installed into the wall cavity behind the thermostat. The Indoor Unit Module is installed at the furnace or air handler. The Heat Pump Module is installed at the heat pump. The Model 7000 also has an optional use built-in fossil fuel kit. 26

28 Model 7000 How It Works 1. When the thermostat calls for the heat pump compressor to run, it will apply power to the Sender Y1 wire which will energize the Y1 relay in the Outdoor Unit Module. This completes the circuit between R and Y1, which will start the compressor. 2. If the heat pump is a 2-stage unit, when power is applied to the Sender Y2 wire, the Y2 relay in the Outdoor Unit Module will energize and cause the compressor to run in high speed. The Y2 relay in Indoor Unit Module will also energize and its Y2 wire is used to switch the fan into high speed. 3. The Sender G wire operates the Indoor Unit fan. 4. The Sender W wire can be connected to thermostat as Aux Heat, Emergency Heat, W or W2 as may be required. It will start the Indoor Unit heating system when power is applied the Sender W wire. 5. The Sender OB wire is used to operate the reversing valve. 6. The Sender R and C wires supply 24 volt power to the thermostat. 7. The Heat Pump Module W wire is connected to the defrost control. When the heat pump is in defrost mode, the indoor unit heating system will start. 8. The Heat Pump Module has an optional use fossil fuel kit. When a thermostat (not included) is mounted at the heat pump, it can be set to a temperature that will shut off the compressor and start the Indoor Unit heating system when the temperature falls to the thermostat set point. On a call for heat, the outdoor thermostat will either run the compressor or start the Indoor Unit heating system based on the outdoor air temperature and the temperature setting of the heat pump located thermostat. 9. There are two wiring methods. One method is referred to as the two transformer method. For this method a transformer is installed at the heat pump. This transformer only provides power the heat pump. The other method is referred to as grounded commons. This method requires that the common wires on the Heat Pump Module are connected to chassis ground. A transformer is not required at the heat pump when using the grounded commons method. 27

29 28

30 29

31 30

32 Model How to Test 1. Test for 24 volt power at the RED and BLACK wires at the Sender, Indoor Unit Module and the Heat Pump Module. If there is no power at any one or more locations check wiring and the control board fuse. If using the grounded commons wiring method, a BLACK wire at the Heat Pump Module must be connected to chassis ground. 2. At the indoor unit, disconnect the wire connected to Heat Pump Module ORANGE and connect this wire to indoor unit R terminal. When 24 volt power is applied to the ORANGE wire, Y1, Y2 & OB should switch on at the Heat Pump Module. Reconnect wiring after testing. 3. At the indoor unit, disconnect the thermostat cable wire connected to Indoor Unit Module PURPLE and connect the PURPLE wire to indoor unit R terminal. When 24 volt power is applied to the PURPLE wire, G & W should switch on at the Indoor Unit. Reconnect wiring after testing. 4. At the indoor unit, disconnect the thermostat cable wire connected to Indoor Unit Module GREY and connect the GREY wire to indoor unit R terminal. When 24 volt power is applied to the GREY wire, W should switch on at the Indoor Unit and Y1, Y2 & OB at the Heat Pump Module should also switch on. Reconnect wiring after testing. 5. At the thermostat, connect the RED to the GREEN then YELLOW, then BROWN, then WHITE, then BLUE. Each function should start when tested. 31

33 Model 9000 Model 9000 The Model 9000 is used for air conditioner to heat pump conversions. It requires a minimum of a 2-wire heat pump cable. It can operate single or 2-stage heat pumps. The Indoor Unit Module is installed at the furnace or air handler. The Heat Pump Module is installed at the heat pump. The Model 9000 also has an optional use built-in fossil fuel kit. 32

34 Model 9000 How It Works 1. When 24 volt power is applied to the Y1, Y2 or OB wires of the Indoor Unit Module, the same wires will be energized at the Heat Pump Module. 2. The Heat Pump Module W wire is connected to the defrost control. When the heat pump is in defrost mode, the indoor unit heating system will start. 3. The Heat Pump Module has an optional use fossil fuel kit. When a thermostat (not included) is mounted at the heat pump, it can be set to a temperature that will shut off the compressor and start the Indoor Unit heating system when the temperature falls to the thermostat set point. On a call for heat, the outdoor thermostat will either run the compressor or start the Indoor Unit heating system based on the outdoor air temperature and the temperature setting of the heat pump located thermostat. 4. There are two wiring methods. One method is referred to as the two transformer method. For this method a transformer is installed at the heat pump. This transformer only provides power the heat pump. The other method is referred to as grounded commons. This method requires that the common wires on the Heat Pump Module are connected to chassis ground. A transformer is not required at the heat pump when using the grounded commons method. 33

35 Model 9000 Grounded Commons Wiring Method DWG 9K-A 34

36 Model 9000 Two Transformers Wiring Method DWG 9K-B 35

37 Model 9000 Zone Panel Wiring Method DWG 9K-C 36

38 Model How to Test 1. Test for 24 volt power at the RED and BLACK wires at the Indoor Unit Module and the Heat Pump Module. If there is no power at any one or more locations check wiring and the control board fuse. If using the grounded commons wiring method, a BLACK wire at the Heat Pump Module must be connected to chassis ground. 2. At the Indoor Unit or Zone Panel, disconnect the wire connected to Heat Pump Module ORANGE and connect this wire to indoor unit R terminal. When 24 volt power is applied to the ORANGE wire, Y1, Y2 & OB should switch on at the Heat Pump Module. Reconnect wiring after testing. 3. At the Zone Panel or Indoor Unit, connect the RED to the YELLOW (Y1), then BROWN (Y2), then BLUE (OB). Each function should start when tested. 37

39 Common Maker Common Maker It is used to add a common connection C at a thermostat. Having a C connection allows for a 24 volt power source which is required by some Wi-Fi thermostats and greatly improves the performance of other Wi-Fi thermostats. It works with all systems including those requiring dry contact switching such some oil burners and zone controllers. 38

40 Common Maker How It Works 1. The BLACK and WHITE Sender wires are connected to the C and W terminals of the thermostat. 2. The Sender PURPLE wire is connected to the thermostat cable and this same wire is connected to the Receiver PURPLE wire. Power then flows from the thermostat R terminal through to C terminal and back through the Sender and Receiver to the transformer. When the thermostat calls for heat, the relay in the Receiver is energized. 3. When the relay is energized, it takes power from the Indoor Unit R terminal and applies it to the W terminal (conventional wiring). Alternatively the Receiver RED and WHITE wires can be connected to an Indoor Unit that requires dry contact switching by connecting these wires to the T or T1/T2 terminals of the Indoor Unit or zone controller. 39

41 40

42 41

43 42

44 43

45 44

46 45

47 46

48 47

49 48

50 49

51 50

52 51

53 Common Maker Testing Method 1. Measure the transformer voltage (often marked as R and C). The meter should read from 24 to 28 volts AC. For furnaces, make sure the door switch is in the on position. 2. Connect the Sender directly to the Receiver: PURPLE to PURPLE, and then connect the Receiver BLACK to transformer C, RED to transformer R. 3. Measure the voltage between the Sender BLACK and the transformer R. The meter should read 21 to 28 volts. 4. Connect the Sender WHITE to the transformer R. The relay in the Receiver should switch on. 5. With Sender WHITE still connected to the transformer R, measure the voltage between the Receiver WHITE wire and the transformer C. The meter should read 24 to 28 volts. Notes If the wires between the Sender and Receiver are crossed during installation, the thermostat will power up but will not switch on the heating system. When in heating mode, the Sender produces about one watt of heat. 52

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable. General Information FAST-STAT wiring extenders electronically add more wires to a control cable. Saves significant time and expense as compared to repulling of new cables. Causes no damage to walls or

More information

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables. Nordic Technology Ltd 1-800-775-4750 www.fast-stat.com This is the printer-friendly edition. o to www.fast-stat.com to download and print additional copies HVA iring Solutions How to add or upgrade residential

More information

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2 FAST-STAT 7000 Nordic Electronics Ltd. 1-800-775-4750 Product Description The FAST-STAT Model 7000 provides 7-wire control from the thermostat to the furnace or fan-coil over a 4-wire cable. This includes,,,,,

More information

FAST-STAT Nordic Electronics Ltd

FAST-STAT Nordic Electronics Ltd FAST-STAT 3000 Nordic Electronics Ltd. 1-800-775-4750 atings Power Input: 20 30 volts AC. Contacts: 3 Normally Open Contact ating: 2 Amps, 24 volt AC Product Description The FAST-STAT Model 3000 provides

More information

PRO Installation. Thermostat Wi-Fi

PRO Installation. Thermostat Wi-Fi PRO Installation Thermostat Wi-Fi 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest connected

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information

PRO Installation. Touch Wi-Fi Thermostat

PRO Installation. Touch Wi-Fi Thermostat PRO Installation Touch Wi-Fi Thermostat 1 Designed by the pros for the pros There are a lot of choices when it comes to buying a thermostat, but only one combines 125 years of experience and the latest

More information

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT THERMOSTATS THERMIDISTAT TM CONTROL MODEL TSTAT ELECTRO-MECHANICAL THERMOSTATS HEAT OFF COOL 90 AUTO FAN ON EM. HEAT 50 * Air Conditioner Model * Heat Pump Model (HH07AT212) (HH07AT214) NON-PROGRAMMABLE

More information

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING Emerson Inspire 1HDEZ-1521 Installation Instructions Thermostat/Interface Equipment Control TROUBLESHOOTING FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL

More information

Nest Thermostat E Pro Installation & Configuration Guide

Nest Thermostat E Pro Installation & Configuration Guide Nest Thermostat E Pro Installation & Configuration Guide Last updated: December 2017 Version: 1.0 Table of Contents General Information 2 Nest Thermostat Installation Features 2 HVAC System Compatibility

More information

Models: 1F95U-42WF, ST75 Version: October Sensi TM. Touch Wi-Fi Thermostat MANUAL OPERATION GUIDE

Models: 1F95U-42WF, ST75 Version: October Sensi TM. Touch Wi-Fi Thermostat MANUAL OPERATION GUIDE Models: 1F95U-42WF, ST75 Version: October 2017 Sensi TM Touch Wi-Fi Thermostat MANUAL OPERATION GUIDE CONTENTS Manual operation guide Buttons and Icons 3 Basic Functionality 4 Menu Settings 5 Installation

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

1F98EZ-1421, Easy Install

1F98EZ-1421, Easy Install 1F98EZ-1421, -1441 Easy Install For up to 4 Stages and 2 Stages Cool INSTALLATION INSTRUCTIONS APPLICATIONS Configuration Options Single Stage Multi Stage Pump Pump with Dual Fuel FAILURE TO READ AND FOLLOW

More information

EL-TSTAT-8820 Safety & Installation Instructions

EL-TSTAT-8820 Safety & Installation Instructions EL-TSTAT-8820 Safety & Installation Instructions TABLE OF CONTENTS WI-FI SETUP Wi-Fi Setup 2 INSTALLATION Installation location recommendations 3 Outdoor temperature sensor (included) 3 Remote temperature

More information

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2 Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS

More information

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat Lyric T6 Pro Wi-Fi Programmable Thermostat Professional Install Guide Package Includes: Lyric T6 PRO Wi-Fi Thermostat UWP Mounting System Honeywell Standard Installation Adapter (J-box adapter) Honeywell

More information

Troubleshooting the Indoor AHU as a Standard Product

Troubleshooting the Indoor AHU as a Standard Product Troubleshooting the Indoor AHU as a Standard Product Indoor Unit Circuit Board Indoor Unit Circuit Board Schematic The TECHs Need to Understand the Status and Fault Codes by LED Lights The control board

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652A 8400 Tstat Install.indd 1 7/23/09 2:20:45 PM Table of contents Installation Installation location recommendations...

More information

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat: SM CAUTION Follow the Installation Instructions before proceeding. Set the thermostat mode to OFF prior to changing settings in setup or restoring Factory Defaults. This Explorer thermostat has the ability

More information

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training Sensi Wi-Fi Thermostat 1F87U-42WF Installation Training Sensi Wi-Fi Thermostat Key Features Universal application (singlestage, multi-stage and heat pump) Compatible with popular smart home platforms Contractor-On-Call

More information

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Smart Temp. ApolloP/n Installation Manual. Version 1.0 Smart Temp ApolloP/n 44-800 Installation Manual Version 1.0 TABLE OF CONTENTS Introduction...6 Getting started...7 Installing the thermostat...8 Disassembly...8 Thermostat location...8 Mounting the subbase...8,

More information

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

Small Digital Thermostat Controller Temperature Control

Small Digital Thermostat Controller Temperature Control www.klimaireintl.com Small Digital Thermostat Controller Temperature Control Small-Fiac IOM Manual KLIMAIRE International +1.647. 477. 3333 +1.646. 808. 0240 klimaireintl@klimaireintl.com Digital Thermostat

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 13 SEER R-410A High Efficiency Split System These units have been designed and tested for capacity & efficiency in accordance with

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 1F82-51 Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems PRODUCT SPECIFICATIONS ZONING IHARMONY Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems Bulletin No. 20663 November 207 Supersedes August 205 COMPONENTS AND EQUIPMENT

More information

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL 500644 FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES A047-001 FIGURE 1: Demand Defrost Control Module ANTI-SHORT CYCLE DELAY

More information

Advanced Installation and Configuration Instructions

Advanced Installation and Configuration Instructions TP-WEM01-A Performance Series AC/HP Wi- Fi Thermostat Carrier Côr Thermostat Advanced Installation and Configuration Instructions Table of contents How to Use This Document... 3 Wiring Diagrams... 4 Installations

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 2-Stage R-410A Split System These units have been designed and tested for capacity & efficiency in accordance with A.H.R.I. Standards.

More information

peaksaver PLUS Program

peaksaver PLUS Program THERMOSTAT TROUBLESHOOTING Blank Screen 1. Make sure that the furnace power is turned on at the breaker panel and ensure fuses are not blown. (Having extra proper-size fuses on hand is a good idea.) 2.

More information

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps Secure Internet Connection Computer Update ColorTouch to firmware version 2.0 or higher* Install the Wi-Fi Key and connect to a local router

More information

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to

More information

Installation Guide for. Energate Thermostats. Pioneer release 2.3 and HōlHōm/Foundation release 3.5

Installation Guide for. Energate Thermostats. Pioneer release 2.3 and HōlHōm/Foundation release 3.5 Installation Guide for Energate Thermostats Pioneer release 2.3 and HōlHōm/Foundation release 3.5 Table of Contents 1 Introduction... 4 1.1 Operating the HōlHōm/Foundation Thermostat... 5 1.2 Operating

More information

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/

More information

ACCESSORY ITEMS FOSSIL FUEL KITS RXPF- SERIES. Model RXPF-F01 Model RXPF-F02

ACCESSORY ITEMS FOSSIL FUEL KITS RXPF- SERIES. Model RXPF-F01 Model RXPF-F02 FORM NO. X11-1117 REV. 7 Supersedes Form No. X11-1117 Rev. 6 ACCESSORY ITEMS FOSSIL FUEL KITS RXPF- SERIES Model RXPF-F01 Model RXPF-F02 IMPORTANT: The RXPF-F01 & RXPF-F02 are designed for use with Rheem

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Installation Manual for Hot Yoga Studio Electric Radiant Heating 105 Comfort System HG-122 Universal Thermostat Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0 More Ah ha! Less Uhhh? For easy to follow programming instructions visit: www.heatinggreen.com/thermostatinstructions-wiring-diagrams/

More information

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the operation of reverse-cycle refrigeration (heat pumps) Explain

More information

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump

Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump Exploratory Lab Testing of a Residential-Scale Combined Space and Water Heating CO 2 Heat Pump ACEEE Hot Water Forum 2017 Session 1B February 27 Ben Larson ben@ecotope.com Problem Statement(s) HFC refrigerants

More information

Installation Instructions

Installation Instructions OWNER'S MANUAL P/N P374-2200 Installation Instructions 70 AUTO TOTALINE 72 COOL o HEAT o 69 Meets California Title 24 Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage * Electric

More information

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS Product Data TSTAT Thermostats Thermidistat TM Control BUILDER S THERMOSTAT * Standard Model (AC, HP) NON-PROGRAMMABLE THERMOSTAT * Standard Model (AC, HP, 2S) PROGRAMMABLE THERMOSTAT AND THERMIDISTAT

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8476 Thermostat with Event-Based Air Cleaning Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 3 Outdoor

More information

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017 Models: 1F95U-42WF, ST75 Version: October 2017 Sensi TM Touch Wi-Fi Thermostat INSTALLATION GUIDE CONTENTS Installation guide Downloading the Sensi app 3 Creating a Sensi account 3 Installing the Sensi

More information

Thermostats. Thermostats

Thermostats. Thermostats Builder Series 500 / 505 Mechanical... 3 1000NC / 1200NC Non-Programmable... 3 2000NC / 2200NC Programmable... 3 1020NC / 1025NC / 1220NC Non-Programmable... 4 2020NC / 2220NC Programmable... 4 Economy

More information

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H Instruction Manual US PAT: 6,824,069 6,786,421 Models: CT03TS21 CTO3TS32 CTO3TS32H www.climatouch.com AED Electronics Inc. 5758 Royalmount Avenue Montreal, Quebec,Canada H4P 1K5 Technical Support: 1-866-90TOUCH

More information

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT THERMOSTATS THERMIDISTAT TM CONTROL MODEL TSTAT BUILDER S MODEL THERMOSTAT * Standard Model (AC, HP) NON-PROGRAMMABLE THERMOSTAT * Standard Model (AC, HP, 2S) PROGRAMMABLE THERMOSTAT, DUAL FUEL, AND THERMIDISTAT

More information

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION Your new White-Rodgers Digital Thermostat

More information

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00 Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P474-1035 Digital Thermostat NOTE: Read the entire instruciton manual before starting the installation. Tu AM SET I2:00 HEAT & COOL 5+2 DAY PROGRAMMABLE

More information

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide. INSTALLATION MANUAL This manual covers TopTech models: TT-N-721 and T721 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux.

More information

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications Installation Guide DIGIU Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications -Zone Controller for the RNC Market Part #DMAN October 004 Zoning Systems That s all we do. INTRODUCTION

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location

More information

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

User & Installer Manual SMT-400 Enterprise Wi-Fi Thermostat User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat Ver 1.01 May 2018 Great care has been taken in the preparation of this manual. Smart Temp Australia P/L takes no responsibility for errors

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide

More information

Omnistat3 Hospitality Energy Management Thermostat

Omnistat3 Hospitality Energy Management Thermostat Omnistat3 Hospitality Energy Management Thermostat and the temperature is set back within 1 minutes (adjustable). When the room becomes occupied, key loads are turned on and the temperature returns to

More information

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA ENGINEERING DATA CONTROLS THERMOSTATS Bulletin No. 210125 November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS L21 SERIES THERMOSTATS HEAT/COOL SYSTEMS Features (All Models): Extra

More information

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Thermostat INSTALLATION GUIDE Models: 1F86U-42WF, UP500W Version: October 2017 2017 Emerson Electric Co. All rights reserved. CONTENTS Installation guide Downloading the Sensi app 3 Creating

More information

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL 5CIM2-0413 W30-AC0056 MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL Multi-zone Hydronic Chiller Interface Module SECTION 1: INTRODUCTION Unit description... 5 Location... 5 Handling... 5

More information

Common Maker Troubleshooting

Common Maker Troubleshooting ommon Overview This document contains testing procedures for the ommon to determine installation errors and equipment faults. ommon Terms Equipment: ny furnace, boiler, zone controller, zone valves, etc,

More information

Daikin ENVi Thermostat installation overview

Daikin ENVi Thermostat installation overview Daikin ENVi Thermostat installation overview RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL Presenter s Name Presenter s Title Daikin ENVi system overview (web based thermostat) Slide 2 Daikin ENVi System Overview

More information

1F80ST /2 Day 5/1/1 Day Non-Programmable 1F86ST-0471

1F80ST /2 Day 5/1/1 Day Non-Programmable 1F86ST-0471 Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. 80 Series Thermostat

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

EnviroZone-4 & EnviroZone-2 Quick-Start Guide EnviroZone-4 & EnviroZone-2 Quick-Start Guide This guide is intended to give the installer a brief set of instructions about how to set up the FHP EnviroZone System. For more detailed information about

More information

Installation Instructions

Installation Instructions P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat

More information

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS 1F83-261 Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS STANDARD PROGRAMMABLE THERMOSTAT

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS STANDARD PROGRAMMABLE THERMOSTAT THERMOSTATS THERMIDISTAT TM CONTROL MODEL TSTAT BUILDER S MODEL THERMOSTAT * Models (AC, HP) STANDARD PROGRAMMABLE THERMOSTAT * Models (AC, HP) NON-PROGRAMMABLE THERMOSTAT * Models (AC, HP, 2S) PROGRAMMABLE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS LOW VOLTAGE CONTROL CIRCUIT WIRING Models: W**A2 W**A2D W**L2 NOTE: For 10 EER models W**AA and W**LA, see low voltage control wiring schematics in unit installation instructions.

More information

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

ONX908MTW-0/24V MULTI STAGE THERMOSTAT ONX908MTW-0/24V MULTI STAGE THERMOSTAT Application: 24VAC,2Heat/2cool Installation and operation instructions SPECIFICATION: Electrical Rating 24VAC Terminal Load 3.0 A per terminal (terminal Y1, W1, G:

More information

Universal Programmable Smart Wi-Fi Thermostat Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool Conventional with wireless Humidity Control*

Universal Programmable Smart Wi-Fi Thermostat Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool Conventional with wireless Humidity Control* Installer Guide TM Universal Programmable Smart Wi-Fi Thermostat 7320 Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool Conventional with wireless Humidity Control* Model number is located on back

More information

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat Fully configurable 1-4 stages heat/ cool Can be configured for heatpumps, air handlers, oil, gas electric furnaces in any combination

More information

5+2 Day. up to HEAT COOL

5+2 Day. up to HEAT COOL Digital Thermostat residential THEMOSTAT T1050 5+2 Day POGAMMABLE up to 2-heat & 2-cool HEAT COOL HEAT PUMP Control up to 2 heat & 2 Cool Stages 4 Settings Per Day Self-prompting programming Auto changeover

More information

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

icomfort Residential Communicating Control System Equipment Interface Module (EIM) PRODUCT SPECIFICATIONS CONTROLS EIM icomfort Residential Communicating Control System Equipment Interface Module (EIM) Bulletin No. 20662 November 207 Supersedes August 205 The Equipment Interface Module

More information

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16) CONTROLS KITS AND ACCESSORIES 2016 Lennox Industries Inc. Dallas, Texas, USA 9/2016 Supersedes11/2015 iharmony Zoning System Installation Instructions for the iharmony Zoning System (10C16) WARNING Improper

More information

INSTRUCTION MANUAL. PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch 3-YEAR WARRANTY

INSTRUCTION MANUAL. PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch 3-YEAR WARRANTY 3-YEAR WARRANTY INSTRUCTION MANUAL PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch LUX Products Corporation 6000 Commerce Parkway, Suite-I Mt. Laurel, NJ 08054

More information

Product Specifications: Application

Product Specifications: Application TH8732WF5018 Lyric Wi-Fi Thermostat Up to 3H/2C Heat Pumps and 2H/2C Conventional Systems Overview: Honeywell s Lyric Thermostat provides comfort when the home is occupied and savings when the homeowner

More information

Smart ways to save energy IntelliCon INSTALLATION MANUAL

Smart ways to save energy IntelliCon INSTALLATION MANUAL Smart ways to save energy IntelliCon INSTALLATION MANUAL, LLC 516-676-0777 www.llc.com 3/6/2006 Air Conditioning General Instructions: General Wiring Instructions 2-1 2 Stage Air Cooled Air Conditioners

More information

IntelliSync Thermostat / Mobile App Frequently Asked Questions

IntelliSync Thermostat / Mobile App Frequently Asked Questions IntelliSync Thermostat / Mobile App Frequently Asked Questions This FAQ page addresses the most common questions on Deriva IntelliSync. Why bother setting a heating and cooling schedule? What is ENERGY

More information

asy Single Day up to 2-heat & 2-cool Stat

asy Single Day up to 2-heat & 2-cool Stat asy Stat Single Day PAMMAB residential THMSTAT TSTATZ world s easiest PAMMAB THMSTAT up to 2-heat & 2-cool utdoor Sensor eady - ompatible with the optional wired, or wireless utdoor Sensor ne for All -

More information

Non-Programmable Digital Thermostat

Non-Programmable Digital Thermostat OWNER'S MANUAL MODEL P474-0140 Non-Programmable Digital Thermostat HEAT PUMP THERMOSTAT 2 HEAT, 1 COOL emergency aux. heat normal energy save Fan On Fan Auto Millivolt Compatible Battery or System Powered

More information

INSTRUCTION MANUAL P Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:

More information

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT APPLICATION These thermostats are designed to operate all R.V. Products ceiling assemblies, which control the air conditioner 115

More information

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7 Installation instructions for Plenum-mounted add-on electric heaters MODEL TU MARCH 2011 version 7 THERMOLEC PLENUM HEATER MODEL TU BEFORE YOU START -GENERAL SAFETY AND INSTALLATION PRECAUTIONS Please

More information

LOW VOLTAGE CONTROL CIRCUIT WIRING

LOW VOLTAGE CONTROL CIRCUIT WIRING INSTALLATION INSTRUCTIONS LOW VOLTAGE CONTROL CIRCUIT WIRING MODELS W**A W**L W**A*D W**L*D Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-507A

More information

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins P-6 Installation and Operation Instructions 3 Heat / 2 ool Heat Pump with Fossil Fuel option Auto hangeover - ooling Priority or Majority Wins Sequence of Operation: Each zone damper is controlled by its

More information

INSTRUCTION MANUAL. LUXPRO PSPU721T 2 Heating and 1 Cooling with Dual Fuel Switch 3-YEAR WARRANTY

INSTRUCTION MANUAL. LUXPRO PSPU721T 2 Heating and 1 Cooling with Dual Fuel Switch 3-YEAR WARRANTY 3-YEAR WARRANTY INSTRUCTION MANUAL LUXPRO PSPU721T 2 Heating and 1 Cooling with Dual Fuel Switch LUX Products Corporation 6000 Commerce Parkway, Suite-I Mt. Laurel, NJ 08054 (856) 234-7905 FAX (856) 234-7825

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Quick Start Guide. Wi-Fi Touchscreen Programmable Thermostat. RET97B5D Wi-Fi Series

Quick Start Guide. Wi-Fi Touchscreen Programmable Thermostat. RET97B5D Wi-Fi Series Quick Start Guide Wi-Fi Touchscreen Programmable Thermostat RET97B5D Wi-Fi Series Welcome Getting set up and ready is simple. 1 2 3 Install your thermostat. Connect your home Wi-Fi network. Register online

More information

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN HOSHIZAKI AMERICA, INC. SERVICE BULLETIN Subject: E SERIES CONTROL BOARD Page 1 of 4 Beginning in February, the KM Universal Alpine replacement control board part number 2U0139-01, will sub to a new Control

More information

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand. CAUTION Follow the Installation Instructions before proceeding. Set the thermostat mode to OFF prior to changing settings in setup or restoring Factory Defaults. This device complies with Part 15 of the

More information

Model number is located on back of thermostat.

Model number is located on back of thermostat. Installer Manual Programmable Thermostats PREMIER SERIES 5020 Single Stage Conventional Systems or Single Stage Heat Pumps with Auxiliary Heat 5220 Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool

More information

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT CONTENTS Installation Instructions for Heating & Air Conditioning 1F79 n-programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. September 2016 Version 7

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. September 2016 Version 7 Installation instructions for Plenum-mounted add-on electric heaters MODEL TU September 2016 Version 7 THERMOLEC PLENUM HEATER MODEL TU BEFORE YOU START -GENERAL SAFETY AND INSTALLATION PRECAUTIONS Please

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

WARNING Important Safety Information

WARNING Important Safety Information 1 Specifications Premier Series Non-Programmable Thermostats MODEL 3000 MODEL 3200 1 2 3 4 5 Specifications Installation Testing Your New Thermostat Programming User Settings Temperature Adjustment WARNING

More information

VisionPRO 8000 with Wi-Fi

VisionPRO 8000 with Wi-Fi VisionPRO 8000 with Wi-Fi FEATURES PRODUCT DATA Thermostat acquires weather data through either a wired sensor or an Internet connection, making for a truly universal installation. U1 Terminals One set

More information

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents. INSTALLATION MANUAL This manual covers TopTech models: TT-S-755H Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers TopTech models: TT-N-851 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information