Heating and Air-Conditioning Testing II. Climatic Test Bench

Size: px
Start display at page:

Download "Heating and Air-Conditioning Testing II. Climatic Test Bench"

Transcription

1 Heating and Air-Conditioning Testing II Climatic Test Bench

2

3 Heating and Air-Conditioning Testing II Climatic Test Bench Content IAV's Climatic Test Benches 4 Mobile Coolant Circuit 6 Evaporator Air Treatment System 8 Condenser Chamber 10 Contact Tanja Vogel

4

5 IAV's Climatic Test Benches The percentage of new vehicles equipped with an air-conditioning system has risen dramatically in recent years. Additional demands, e.g. for fuel-efficient engines and weightoptimized components with unchanged cooling performance, have given rise to a constant growth in development input for air-conditioning systems. In response to this situation, IAV has installed a climatic test bench for developing and designing air-conditioning systems. In addition to designing and determining the performance of individual air-conditioning components, the test bench in particular provides the means for conducting measurements on the: u overall system with OEM lines and components u front-end section with radiator/fan package u heating/air-conditioner u overall vehicle at idle. 4 5

6 Condenser chamber Collector I Collector II Evaporator air treatment system Expansion valve External vehicle condenser (test component) Internal condenser Internal evaporator External vehicle evaporator (test component) Oil separator Vehicle air-conditioner compressor

7 Mobile Coolant Circuit Technical Specifications u Features 1 Internal evaporator 12 kw max. 1 Internal condenser 20 kw max. 1 Electrical compressor drive u Control Variables 1 Compressor speed 500 to 9000 rpm 1 Evaporation pressure 2.5 to 5 bar 1 Overheating 0 to 20 K 1 Undercooling 0 to 20 K 1 Hot gas temperature control 60 to 150 C Configuration Capabilities u Connection of vehicle evaporators and/or vehicle condensers u Integration of different air-conditioner compressors Scope of Testing u Performance measurement on vehicle air-conditioner compressors u Torque measurement u Determination of performance characteristic of vehicle air-conditioner compressors u Measurement Variables 1 Torque 1 Coolant mass flow 1 Temperature and pressure recording 1 Throughout the mobile coolant circuit u Power Output for Compressor 1 0 to 30 V; 0 to 10 A Cooling capacity Ps1 Ps2 u Safety Features 1 Low-pressure shut-off < 2 bar 1 High-pressure shut-off > 35 bar 1 Hot gas temperature shut-off > 150 C Speed [rpm] Mobile Coolant Circuit Compressor speed Condensation pressure control Evaporation pressure control Overheating, controllable between Undercooling, controllable between 500 to 9000 rpm 5 to 30 bar 2.5 to 5 bar 0 and 20 K 0 and 20 K Hot gas temperature control 60 to 150 C Capacity of internal evaporator Capacity of internal condenser Torque measurement Mass flow measurement Pressure and temperature measurement 12 kw 20 kw at the drive motor on Coriolis measurement system upstream and down stream of each component in the cooling circuit 6 7

8 Dehumidifying Cooling Heating Lateral air discharge into shop Steam humidifier Orifice plate flowmeters Air discharge at front; Connection for air conditioner or frame Shop air intake Lateral air discharge into condenser chamber

9 Evaporator Air Treatment Systems Technical Specifications u Temperature and Humidity 1 Temperature range: -20 to 60 C 1 Rate of change: 1 K/min 1 Relative humidity: 10 to 95 % u Air Flow 1 Air volume flow: 80 to 800 m 3 /h 1 Small-diameter orifice plate flowmeter: 80 to 200 m 3 /h 1 Large-diameter orifice plate flowmeter: 100 to 800 m 3 /h 1 Air discharge cross section 600 x 400 mm 1 Air discharge cross section 150 mm Ø 1 Air volume flow is adjustable by regulating volume flow or differential pressure u Sensors 1 45 thermocouples 1 1 humidity sensor 1 1 differential pressure sensor 1 1 pressure capsule for ambient pressure u Power Supply Unit Output (e.g. for air-conditioning system) 1 0 to 35 V; 0 to 40 A u Other Features 1 Discharge flange into condenser chamber and at side into shop, with connection for insulated hose Configuration Capabilities u Heating/air-conditioning system on a test rack u Evaporator in a test frame u Vehicle or empty body in the condenser chamber or next to evaporator air treatment system u Measurement of two evaporator systems Scope of Testing u Performance measurements at the evaporator coolant and air side u Air-side pressure loss measurements at the evaporator u Absence-of-water measurements at the air-conditioner u Measurements at the expansion valve u Blower characteristic u Control curve u Heating performance Evaporator Air Treatment System Temperature range -20 to +60 C Rate of temperature change 1 K/min Relative air humidity 10 to 95% Air volume flow 80 to 800 m 3 /h Outlet size at front approx. 300 x 400 mm Lateral air outlet 2 x 150 mm Ø 8 9

10 Volume flow measurement Air recirculation system for chamber temperature control Condenser air outlet

11 Condenser Chamber Technical Specifications u Air Recirculation System 1 Temperature range: C 1 Rate of change: 1 K/min u Condenser Air Duct 1 Air volume flow: 200 to 8000 m 3 /h 1 Discharge outlet size approx. 700 x 900 mm u Compressor Drive 1 Speed: 500 to 9000 rpm u Sensors 1 52 thermocouples 1 5 pressure sensors 1 2 humidity sensors 1 1 pressure pick-up (air side) 1 1 differential-pressure capsule u Power Supply Unit Output (e.g. for Radiator Fan) V; A u Other Features 1 Exhaust gas extraction/fresh-air intake 1 Discharge flange for evaporator air treatment system Configuration Capabilities u Vehicle, front vehicle or front end with air flowing through condenser air duct u Complete vehicle coolant circuit in test rack u Radiator/fan package u Condenser in test frame in the condenser air duct Scope of Testing u Performance measurements on condensers, coolant and air side u Pressure loss measurements on condensers, coolant and air side u Tests on the entire coolant circuit or entire vehicle u Filling quantity optimization u Cooling behavior in passenger compartment Condenser Chamber Temperature range -20 to +60 C Rate of temperature change 1 K/min Air volume flow 200 to 8000 m 3 /h Size of air-circulation duct outlet approx. 700 x 900 mm Speed range of compressor drive motor 500 to 9000 rpm Connection to evaporator air treatment system 150 mm Ø 10 11

12 IAV GmbH Carnotstrasse BERLIN GERMANY Tel Fax Excellence in Automotive Research & Development

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 SAE Alternate Refrigerant Cooperative Research Program Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 To: Alternate Refrigerant Task Force Members From: Ward Atkinson

More information

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel. DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the

More information

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay Effect of Refrigerant Charge, Compressor Speed and Air Flow through the Evaporator on the Performance of an Automotive Air Conditioning System 15 th International Refrigeration and Air July 14-17, 2014

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-10 DUCT

More information

Climate Control System

Climate Control System Page 1 of 13 SECTION 412-00: Climate Control System General Information DESCRIPTION AND OPERATION 1998 Mark VIII Workshop Manual Climate Control System Cautions and Warnings WARNING: To avoid accidental

More information

Refrigerant Mass and Oil Migration During Start-up Transient

Refrigerant Mass and Oil Migration During Start-up Transient Refrigerant Mass and Oil Migration During Start-up Transient Steffen Peuker, Predrag Hrnjak* Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign 1206 West Green

More information

Heat pump supplemental heating system for motor vehicles

Heat pump supplemental heating system for motor vehicles 1 Heat pump supplemental heating system for motor vehicles D Antonijevic and R Heckt Visteon Automotive Systems, Visteon Deutschland GmbH, Kerpen, Germany Abstract: The paper deals with the importance

More information

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION REFRIGERATION AND AIR CONDITIONING CUSSONS LABORATORY RECOMMENDATION Cussons Refrigeration laboratories are offered to provide teaching to a range of different skill levels. In all the laboratories teaching

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT

More information

HEATER, AIR CONDITIONER AND VENTILATION

HEATER, AIR CONDITIONER AND VENTILATION GROUP 55 HEATER, AIR CONDITIONER AND VENTILATION CONTENTS GENERAL INFORMATION........ 55-2 HEATER UNIT.................. 55-5 HEATER CONTROL............. 55-7 A/C-ECU....................... 55-8 DUCTS........................

More information

1 - High-velocity gas burners

1 - High-velocity gas burners 1 - High-velocity gas burners General information: Rev.: 28.08.2016 High-velocity gas burners of the B202 H1-H5 series are available with various design options. The standard or basic type comes with ceramic

More information

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER PRE-HEATERS YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER Have to stay in the iced-up car to start and idle the engine to warm up the engine block and cab inside for over 15 minutes everyday in the cold winter?

More information

Homework Chapter2. Homework Chapter3

Homework Chapter2. Homework Chapter3 Homework Chapter2 2/1 A storage tank holds methane at 120 K, with a quality of 25 %, and it warms up by 5 C per hour due to a failure in the refrigeration system. How long time will it take before the

More information

STR-600 Impact Dryer

STR-600 Impact Dryer STR-600 Impact Dryer 1. STR-600 Main Features The STR-600 is designed for moisture damage drying of targeted areas. The device can be used for drying various stone-based materials, such as concrete, brick

More information

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel

More information

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer Technical Report Improved energy efficiency in refrigeration plants According to the European EDL directive (final energy efficiency and energy services), 9 % energy savings over a nine-year-period in

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

R07. Answer any FIVE Questions All Questions carry equal marks *****

R07. Answer any FIVE Questions All Questions carry equal marks ***** Set No: 1 III B.Tech. II Semester Supplementary Examinations, April/May 2013 REFRIGERATION AND AIR CONDITIONING (Mechanical Engineering) Time: 3 Hours Max Marks: 80 Answer any FIVE Questions All Questions

More information

Mobile climate solutions

Mobile climate solutions Mobile climate solutions Roof air conditioners 102 111 Under-bench air conditioner 112 11 www.dometic-waeco.com 9 95 9 Mobile climate solutions Climate as desired Take your pick: the Dometic range offers

More information

container glass table ware glass decoration speciality glass float glass pattern glass Float- and Display Glass Annealing Lehr

container glass table ware glass decoration speciality glass float glass pattern glass Float- and Display Glass Annealing Lehr container glass table ware glass decoration speciality glass float glass pattern glass Float- and Display Glass Annealing Lehr www.pennekamp.de Tradition, Innovation, Future. Discover our strength. History

More information

HEATING AND VENTILATION

HEATING AND VENTILATION SECTION 14-102.04 14-102.04/ 1 2007OC19 DESCRIPTION The heating, ventilation and air conditioning (HVAC) system is designed to optimize passenger comfort. The system regulates interior vehicle atmosphere,

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7 CONTENTS Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7 6. CONSTRUCTION / MATERIALS 8 7. DIMENSIONS 8 8. LAYOUT 12 9. PRINCIPLE

More information

EVANS TEMPCON DASH HEATER A/C All Electric Control Systems

EVANS TEMPCON DASH HEATER A/C All Electric Control Systems EVANS TEMPCON DASH HEATER A/C All Electric Control Systems Owner s Manual Operating Instructions For additional owner and operator information visit us on the web at www.evanstempcon.com WARNING This heater

More information

May 26, 2006, /2, Supersedes Technical Bulletin Group 87 number 03-01, dated May 13, 2003 due to updated treatment procedures.

May 26, 2006, /2, Supersedes Technical Bulletin Group 87 number 03-01, dated May 13, 2003 due to updated treatment procedures. Condition Musty Odor from Heating and Ventilation System Unpleasant, musty odor from Heating and Ventilation system. 87 06 01 May 26, 2006, 2005566/2, Supersedes Group 87 number 03-01, dated May 13, 2003

More information

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating The High Efficiency AYF60-119 units are 2 module appliances; each AYF is

More information

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb) CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used

More information

TEMPERATURE SHOCK TEST CHAMBERS

TEMPERATURE SHOCK TEST CHAMBERS E SHOCK TEST CHAMBERS TEST STANDARDS VARIOUS TEST POSSIBILITIES Thanks to rapid and high-speed temperature change tests, failures on products which will undergo such extreme impacts can be detected in

More information

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Technical Report An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Hironobu Kurara, Custom Equipment Engineering Department 2, Custom Equipment

More information

Liquid Ring Vacuum Pumps, Compressors and Systems

Liquid Ring Vacuum Pumps, Compressors and Systems Helmut Bannwarth Liquid Ring Vacuum Pumps, Compressors and Systems Conventional and Hermetic Design Translated by Christine Ahner WILEY- VCH WILEY-VCH Verlag GmbH & Co. KGaA XIII Foreword VII Preface IX

More information

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10 Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in

More information

SONAPHONE. Performance test of steam traps Supplement to the operating manual

SONAPHONE. Performance test of steam traps Supplement to the operating manual SONAPHONE Performance test of steam traps Supplement to the operating manual SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Str. 2 06112 Halle (Saale), Germany Phone: +49 (0)345 133 17-0 Fax: +49 (0)345

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

BC BRONCOS AIR CONDITIONING UNIT

BC BRONCOS AIR CONDITIONING UNIT BC BRONCOS AIR CONDITIONING UNIT CAUTION If you are not familiar with the principals of air conditioning, have an authorized air conditioning technician evacuate and charge the system. Serious damage to

More information

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m. heater product range commercial 11 HYDRONIC EBERSPÄCHER WATER HEATERS THE RIGHT HEAT WHERE YOU WANT IT The advantage of Eberspächer water heaters is that they pre-heat both the vehicle interior and the

More information

Boreas DV DV AB / WB

Boreas DV DV AB / WB Boreas DV 1260 - DV 2 AB / WB Air cooled / water cooled Refrigeration Dryers PRODUCT DESCRIPTION MA FEATURES & BENEFITS Refrigeration compressed air dryer for safe and economical compressed air drying

More information

Mobile climate solutions

Mobile climate solutions Mobile climate solutions 108 121 Under-bench air conditioners 122 12 102 10 102 Air conditioners Climate as desired Take your pick: the Dometic range offers air conditioners in all performance categories

More information

COOPERATIVE PATENT CLASSIFICATION

COOPERATIVE PATENT CLASSIFICATION CPC B COOPERATIVE PATENT CLASSIFICATION PERFORMING OPERATIONS; TRANSPORTING (NOTES omitted) TRANSPORTING B60 VEHICLES IN GENERAL (NOTE omitted) B60H ARRANGEMENTS OR ADAPTATIONS OF HEATING, COOLING, VENTILATING,

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

CLIMATE EBERSPÄCHER DIESEL HEATERS MOBILE LIVING MADE EASY.

CLIMATE EBERSPÄCHER DIESEL HEATERS MOBILE LIVING MADE EASY. CLIMATE EBERSPÄCHER DIESEL HEATERS MOBILE LIVING MADE EASY. EBERSPÄCHER AIRTRONIC AIR HEATER Cosy warmth during the day and night The Eberspächer AIRTRONIC provides a level of performance and comfort that

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING PL HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page REMOVAL AND INSTALLATION EVAPORATOR CORE R. H. D....1 HEATERCORE R.H.D...3 page SPECIFICATIONS TORQUE SPECIFICATIONS...6

More information

HEATING. Additional heating

HEATING. Additional heating 161 61 Additional heating OPERATING PRINCIPLE The vehicle with a G9T engine is fitted with an additional heating system as an option in some countries (Germany, Nordic countries...). This comprises an

More information

HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS. Reduce costs for compressed air generation

HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS. Reduce costs for compressed air generation HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS Reduce costs for compressed air generation REDUCE COSTS FOR COMPRESSED AIR GENERATION BENEFIT FROM SAVINGS POTENTIALS. Dwindling resources, stringent

More information

1998 Expedition/Navigator Workshop Manual

1998 Expedition/Navigator Workshop Manual Page 1 of 8 SECTION 412-00: Climate Control System - General Information 1998 Expedition/Navigator Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 02/11/2000 Climate Control System WARNING:

More information

NTC Thermistor Temperature Sensors. Product Information and Application Notes

NTC Thermistor Temperature Sensors. Product Information and Application Notes NTC Thermistor Temperature Sensors Product Information and Application Notes Contents 10J Series... 3 11J Series... 4 12J Series... 5 13J Series... 6 15J and 16J Series... 7 36J Series... 8 74J and 75J

More information

SCHNEIDER-KESSEL BERLIN

SCHNEIDER-KESSEL BERLIN SCHNEIDER-KESSEL BERLIN STEAM BOILER and HOT WATER BOILER HIGH PRESSURE STEAM GENERATOR - Series inook GENERAL The inook is a high pressure steam generator especially designed for closed steam-condensate

More information

Air Conditioning Systems

Air Conditioning Systems Air Conditioning Systems Application Examples Telecommunications and static locations Scaleable cooling systems Container based cooling and heating applications Range of control options Contents RTU-1

More information

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA L14 ENVIRONMENTAL CONTROL Ever since components have been made to control electrotechnical tasks, heat loss has been a subject to take into consideration. Sometimes more sometimes less. Major problems

More information

Cooling water/oil heat exchanger with water thermostatic mixer

Cooling water/oil heat exchanger with water thermostatic mixer Cooling water/oil heat exchanger with water thermostatic mixer Four-way water thermostat to control the coolant temperature with built-in heat exchanger. Significantly shortens the warm-up phase of the

More information

Heating and Cooling Systems

Heating and Cooling Systems Heating and Cooling Systems Figure 1. Typical Engine Cooling System Introduction Engines generate a great amount of heat. This heat is created when the fuel and air mixture is ignited and expands inside

More information

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Type Test chamber capacity SC 2000 MHG approx. 3400 l Radiation area approx. 1.36 m 2 TECHNICAL DATA Characteristic values for

More information

Since 1983 Nuova COTERM has developed a wide range of water heaters.

Since 1983 Nuova COTERM has developed a wide range of water heaters. Since 1983 Nuova COTERM has developed a wide range of water heaters. Thank to careful attention to market demands and continuous research towards new solutions, Nuova COTERM is able to offer clients the

More information

A660 Air Conditioning Laboratory Unit

A660 Air Conditioning Laboratory Unit A660 Air Conditioning Laboratory Unit Figure 1: A660 Base Unit shown with all options fitted High accuracy wet and dry bulb sensors before and after each process to determine air condition. All processes

More information

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL Dehumidification systems for private indoor swimming pools, Dehumidification for swimming pools, hotels, spas or therapeutic clinics spas and therapeutic clinics

More information

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install

More information

Innovative Air Conditioning for Hybrid and Electric Vehicles

Innovative Air Conditioning for Hybrid and Electric Vehicles 1 Innovative Air Conditioning for Hybrid and Electric Vehicles Walter FERRARIS (CRF) 2013-05-22 Summary 2 Scenario Air Conditioning and Thermal Comfort New automotive air conditioning concepts Inversion

More information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c

More information

4-2. Ventilator control. & Rear ventilators (if equipped) & Side ventilators. & Center ventilators

4-2. Ventilator control. & Rear ventilators (if equipped) & Side ventilators. & Center ventilators Climate control Ventilator control... 4-2 Center ventilators... 4-2 Side ventilators... 4-2 Rear ventilators (if equipped)... 4-2 Climate control panel... 4-3 Type A... 4-3 Type B... 4-4 Automatic climate

More information

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers Boreas DV 1260 - DV 2 AVS / WVS Air cooled / water cooled Refrigeration Dryers PRODUCT DESCRIPTION Boreas DV 1260 - DV 2 For the energy-conscious user, the new Boreas DV refrigeration compressed air dryers

More information

Industrial cooling systems LT

Industrial cooling systems LT Industrial cooling systems LT 01 Industrial cooling and heating. Partner of the industry for over 40 years. Since 1971 DELTATHERM has belonged to Hirmer GmbH, a family business with its headquarters in

More information

WHITE PAPER: Thermal Management Solutions

WHITE PAPER: Thermal Management Solutions WHITE PAPER: Air Conditioners What is Air Conditioning? Air conditioning by definition is a means to cool and remove humidity from an environment, such as an enclosure, through use of a refrigerant cooling

More information

AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC

AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC AquaMobil Mobile shower, decontamination and heating systems SWINGTEC Our first mobile water flow heater, type DH1, was developed and built as early as 1962. Approximately 4,000 devices of this type were

More information

Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger

Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger Experimental Performance Analysis of an Automotive Air Conditioning and Heat Pump System using R134a with and without Internal Heat Exchanger Erkutay ASDEMIRCI, Ertan ALPEKIN, Murat HOSOZ Abstract In this

More information

Section 12-00: Climate Control System Service 1997 Town Car Workshop Manual DIAGNOSIS AND TESTING Procedure revision date: 06/29/2000 Climate Control System Inspection and Verification 1. Verify the customer's

More information

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators PN: 89-3048 Evaporator EM-1 Our EM-1 ceiling mount air conditioning evaporator has been engineered for maximum serviceability and ease of installation in commercial and school buses. Because the drain

More information

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m) The SKH pumps water at high pressure through a series of nozzles to produce a fine mist. By way of the adiabatic process, the SKH uses energy (heat) from the surrounding air to evaporate the fine mist

More information

PROCESS AND CLIMATE COOLING

PROCESS AND CLIMATE COOLING PROCESS AND CLIMATE COOLING air cooling Creating a good indoor climate. Tailor-made climate control for technical rooms Cooling at high thermal loads Air conditioning is not just an issue in summer. There

More information

Innovative Components for Additional Heating Systems

Innovative Components for Additional Heating Systems Innovative Components for Additional Heating Systems Dipl. Ing. Frank Wolf Dipl. Ing. (FH) Norbert Tessendorf Phone: 0043 - (0) 5577-62370 Fax: 0043 - (0) 5577-623709 Mobile: 0043 - (0) 664-1019620 Em@il:

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION PERFORMANCE EVALUAION OF CO 2 HEA PUMP HEAING SYSEM O. KUWABARA (a), M. KOBAYASHI (a), H. MUKAIYAMA (a) M. ISHIKAWA (b), K. MUKUNOKI (b), N. HONMA (b) (a) R&D Headquarters, Sanyo Electric Co., Ltd. 1-1-1,

More information

Environmental Systems

Environmental Systems Environmental Systems 21-00: ENVIRONMENTAL SYSTEMS 1. General This section covers those systems and components used to furnish a means of heating, cooling, and treating the air used to ventilate the areas

More information

2013 ASHRAE. Standards & Guidelines CD. Contents

2013 ASHRAE. Standards & Guidelines CD. Contents 2013 ASHRAE Standards & Guidelines CD Contents ANSI/ARI/ASHRAE ISO Standard 13256-1:1998 (RA 2012) Water-source heat pumps testing and rating for performance Part 1: Water-to-air and brine-to-air heat

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Troubleshooting the Indoor AHU as a Standard Product

Troubleshooting the Indoor AHU as a Standard Product Troubleshooting the Indoor AHU as a Standard Product Indoor Unit Circuit Board Indoor Unit Circuit Board Schematic The TECHs Need to Understand the Status and Fault Codes by LED Lights The control board

More information

Munters DesiCool removes excess heat in server room

Munters DesiCool removes excess heat in server room Munters DesiCool removes excess heat in server room DesiCool Corporate IT in Copenhagen University is bringing all their servers into two large server rooms located respectively in Copenhagen University

More information

State of the Art. Exceptional Reliability

State of the Art. Exceptional Reliability State of the Art The SKG 3000 uses the most advanced, commercially available gas technology ensuring consistent and efficient combustion. The same technology self-adjusts for altitude compensation and

More information

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells STAR Global Conference Sebastian Bilz, Vladimir Buday, Carolus Gruenig, Thomas von Unwerth Vienna, March 17-19, 2014 1 CFD Simulation of

More information

Plant growth chambers

Plant growth chambers Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect

More information

V-Line. Nozzle-mix line burner

V-Line. Nozzle-mix line burner V-Line Nozzle-mix line burner Duct Burners - V-Line 4-22.5-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane. Suitable for operation in variable process air-flows. Stainless

More information

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems OBJECTIVES Warning: though the experiment has educational objectives (to learn about boiling heat transfer, etc.), these should not

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660 Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated

More information

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Heat Pumps SA SERIES Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum and reduced maintenance Double wall rigid polyurethane foam injected panel

More information

Heated tools. Semiconductor equipment

Heated tools. Semiconductor equipment Heated tools Semiconductor equipment Ceramic heating elements made of silicon nitride and aluminum nitride can be manufactured as tools in various shapes. The heating function can be integrated in complex

More information

IAV Primero. Fault Simulation for Lambda Probes

IAV Primero. Fault Simulation for Lambda Probes IAV Primero Fault Simulation for Lambda Probes What we develop moves you IAV Your Partner for Automotive Engineering Our engineering is at the heart of vehicles across the globe. As one of the leading

More information

Heat recovery systems. For hot air and hot water applications.

Heat recovery systems. For hot air and hot water applications. Heat recovery systems For hot air and hot water applications www.kaeser.com Heat recovery systems Why recover heat? The question should in fact be: Why not? Amazingly, practically 100 percent of the electrical

More information

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger , July 6-8, 2011, London, U.K. Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger Avinash. D. Desai, S. N. Sapali, Parthasarathi. V. Garikipati Abstract:

More information

Heat-Engineering Trainer. (Refrigeration, Air Conditioning, Boiler, Geothermal)

Heat-Engineering Trainer. (Refrigeration, Air Conditioning, Boiler, Geothermal) Heat-Engineering Trainer (Refrigeration, Air Conditioning, Boiler, Geothermal) Standard Refrigeration trainer (AV-RH-R-1000) 1. The possibility of the experiment on temperature, pressure, automatic control

More information

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE. DFE T ECHNOLOGY As components become smaller, component mixes become more diverse, and board densities continue to increase, the processes of packaging, interconnection, and assembly are challenging the

More information

DIGI-VAV APPLICATIONS

DIGI-VAV APPLICATIONS DIGI-VAV DIGI-VAV APPLICATIONS Digi-VAV: An optimization kit for Variable Air Volume Air Handling Units (VAV AHU) that ensures individual zone indoor air quality (IAQ), and minimizes system energy consumption.

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

1. General Description

1. General Description 1. General Description A: SPECIFICATIONS 1. HEATER SYSTEM Heating capacity 2. A/C SYSTEM AUTO A/C MODEL Item Specifications Condition 5.0 kw (4,300 kcal/h, 17,062 BTU/h) or more AC-2 Mode selector switch:

More information

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings Revamping Kits and Digital Solutions for quality improvement and energy savings Burners Sacmi for energy savings Complete range of burners for all fuel types. Heads specially designed for different capacities

More information

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems Variable Speed Drives: Reducing the energy costs of commercial HVAC systems Factsheet Using Variable Speed Drives (VSDs) to reduce the cost of heating, ventilation and air conditioning (HVAC) systems in

More information

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006 Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #4 System Drop-in Test of Refrigerant R-32 in Split System Heat

More information

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS A. Hafner SINTEF Energy Research Refrigeration and Air Conditioning Trondheim (Norway) ABSTRACT The natural refrigerant carbon dioxide (CO 2 ) with all its

More information