1 Replacement Parts List No Revision F /07 Daikin McQuay Templifier Scroll Compressor Water Heater TGZ Vintage B To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History... Nomenclature Serial Number...4 Unit Model Number...4 Unit Model Number- Complete..., 6 Electrical Legend...7 Typical Unit Layout Diagrams...8 Refrigeration Section Piping Schematics...9 Compressors, Evaporator, & Condenser: TGZ B...0 Compressors, Sound Blankets: TGZ B... Compressors, Evaporator, & Condenser: TGZ080-0B... Compressors, Sound Blankets: TGZ080-0B... Compressors, Evaporator, & Condenser: TGZ0-90B...4 Compressors, Sound Blankets: TGZ0-90B... Compressor Trio Piping: TGZ0-90B...6 Liquid Line TGZ B...7 TGZ080-0B...8 TGZ0-90B...9 Hot Gas Bypass: (Code 4= HG) TGZ040-0B...0 TGZ0-90B... Suction Line TGZ B... TGZ080-0B... TGZ0-90B...4 Discharge Line TGZ B... TGZ080-0B...6 TGZ0-90B...7 Condenser Components...8 Shell and Tube Evaporator Components: TGZ0-90B...9 Water Flow Switch: (Code = AA, BB)...0 Control Box Control Box Layout Diagrams & Data Nameplate... Common Control Box Components... Transformers & Fuses... Components for Units Without Compressor Overloads: (Code = NONE) TGZ B...4 TGZ080-0B..., 6 TGZ0-00B...7, 8 Components for Units With Compressor Overloads: (Code = WTOL) TGZ B...9, 40 TGZ080-0B TGZ0-90B Communication Modules...47 Vibration Isolator Kits...48 Field Installed Accessories...49 Critical Parts List Critical Parts List...CPL, Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

3 Parts List Revision History Revision Date Description NEW 04/ New A 09/ Various: Changed "McQuay Parts" to "Daikin McQuay Parts". CPL, (NEW): Added Critical Parts List (CPL). Repaginated form and updated TOC. B / Pages 0,, 4: Removed Pressure Transducers from this page, duplication of info on page. Page 9: Corrected part # for Ref. 0/0 Valve -EXV, was Page 8: Updated part #s for Ref. 0 Gasket Heads for 4" (was 08760) and 6" (was 08760). Page : Corrected part #s for Schem. S0,0 Low Pr Transducer, was Corrected part #s for Schem. S0,04 High Pr Transducer, was Page 48: Removed Spring Isolator information, added note to contact Daikin Applied. Pages 0, : Updated CPL page format. Corrected part #s for Low Pr Transducer (was 7640); High Pr Transducer (was 76460); and Electronic Exp Valve (was 0860). C 0/ Cover, Rev. Pg.: Updated to Daikin Legacy logo format. Cover, Master: Changed title from"water Source Templifier..." to "Templifier Scroll Cmpr. Water Heater". CPL, : Updated to Daikin Legacy format. D 0/06 Page 9: Corrected Part # for Ref. Suction O-Ring, was E446. E 0/07 Page 6: Code 8- Added F and W. Code 9- Changed "Always Y" to "Brand Name", added codes DM, MC and JD. Code - Added CPE & CBE thru 9. Code 4- Added EPE & EBE thru 9. Code - Added RS6 thru 9, and T. Page : Added part #s for Compressors. Page : Added part #s for Compressors. Page 4: Updated part #s for Ref. 00, Evap Assy, 0B was 9990 & 70B/90B was Page : Added part #s for Compressors. Page : Updated p/n for Ref S0,0 Low Pr Transducer, was 0768; and Ref S0,04, Hi Pr Transducer, was Page CPL: Updated p/n for Low Pr Transducer, was 0768; and Hi Pr Transducer, was F /07 Page : Updated info for Transducers to include part #s for units built before & after Sept. 07. Page CPL: Updated info for Transducers to include part #s for units built before & after Sept. 07. Daikin Applied, 600 Industrial Park Blvd., P.O. Box, Minneapolis, MN 440 (76) -0 Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

4 Nomenclature Serial Number & Unit Model Number Serial Number STN U Plant Identification STN = Staunton, VA U= Unit Serial Number (build sequence) Year of Manufacture = 0 = 0 4= 04 = 0 6= 06 etc. Month of Manufacture 0= January 07= July 0= February 08= August 0= March 09= September 04= April 0= October 0= May = November 06= June = December Unit Model Number TGZ 060 A W Platform W= Standard Packaged Unit Vintage Nominal Tonnage ex. 060= 060 Tons Unit Type: TGZ= Water- Cooled Scroll Compressor Chiller Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

5 Nomenclature Unit Model Number- Complete TGZ 060B W A NN S S NN A R 4 A NN MSE NONE 7 AL MN V F N AA S HG TE Code: NN T N NN DSU DPN NON CPE NNNN NNN D00 NN NN S Size (in nominal tons) 040B= 40 Tons "B" Vintage 00B= 0 Tons "B" Vintage 060B= 60 Tons "B" Vintage 080B= 80 Tons "B" Vintage 00B= 00 Tons "B" Vintage 0B= 0 Tons "B" Vintage 0B= 0 Tons "B" Vintage 0B= 0 Tons "B" Vintage 70B= 70 Tons "B" Vintage 90B= 90 Tons "B" Vintage 0 Platform W= Standard Packaged Unit 04 Refrigerant A= R4a 0 Efficiency / Sound NN= Standard Efficiency & Sound WS= With Compressor Sound Reduction 06 Evaporator Insulation S= Single Layer 07 Unit Operation S= Standard LWT Operation (0 F- 60 F Cond. LWT/ 4 F- 8 F Evap. LWT) B= Lower LWT Operation (0 F- 9 F Evap. LWT) 08 Always NN 09 Condenser Materials A= Copper Tubes 0 Condenser Connection L= Left Hand R= Right Hand Condenser Water Flow = Pass Water Head for 0 F Delta LWT-EWT 4= 4 Pass Water Head for 0 F Delta LWT-EWT Additional Switch A= Heat/Cool Control Selection Switch Communication NN= None LN= LonMark BN= BACnet MS/TP EN= BACnet Ethernet OR IP MN= Modbus 4 Controls MSE= MicroTech II, English MSD= MicroTech II, English w/ Remote Display Overloads NONE= No Compressor Supplementary Overloads WTOL= With Compressor Supplementary Overloads 6 Voltage = 08/60/ 9= 0/60/ 7= 460/60/ 7= 7/60/ = 400/0/ 7 Starting AL= Across the Line 8 Power Connection PC= Single Point Power Block & Compressor Circuit Breakers DC= Single Point Disconnect Switch & Compressor Circuit Breakers MN= Multiple Point Power Block; No Compressor Circuit Breakers WN= Multiple Point Disconnect; No Compressor Circuit Breakers DH= High Short Circuit Current Rating w/ Single Point Disconnect 9 Phase Voltage N= None V= Phase & Under/Over Voltage Protection w/ LED 0 Ground Fault N= No Ground Fault Protection F= Ground Fault Protection Unit Options N= No Unit Options Water Flow Indication NN= None AA= Evaporator Only BB= Evaporator & Condenser Field Options S= Single Evap. & Cond. Pumps, Single Control Output D= Dual Evap. & Cond. Pumps, Dual Control Output 4 Tubing Options NN= Liquid & Discharge Line Shut-Off Valves HG= Hot Gas Bypass w/ HGBP Valves Unit Controls TE= Thermal Expansion Valve (TGZ040-0B) EE= Electronic Expansion Valve (TGZ0-90B) 6 Unit Packaging NN= None SK= Wood Skid PT= Unit Painted SP= Wood Skid & Unit Painted Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

6 Nomenclature Unit Model Number- Complete, Continued 7 Approvals T= ETL/CETL Approval & NO AHRI approval A= No Approval 8 CRN = British Columbia = Alberta = Saskatchewan 4= Manitoba = Ontario 6= Quebec 7= New Brunswick 8= Nova Scotia 9= Prince Edward Island 0= Newfoundland F= Nunavut U = Yukon W= Northwest Territories N= No CRN Required X= Special 9 Brand Name DM= Daikin McQuay MC= McQuay JD= Daikin 0 Unit Start DSU= Domestic Startup CSU= Canadian Startup ISU= International, No Startup provided Standard Warranty DPN= Domestic, yr. std. warranty - parts only CPN= Canadian, yr. std. warranty - parts only TPN= International, yr. std. warranty - parts only First Year Labor Warranty NON= None AC= Compressor only AE=Entire Unit. Extended Compressor Warranty CPE= Compressor only - Ext. year parts only CBE= Compressor only - Ext. year parts & labor CPE= Compressor only - Ext. year parts only CBE= Compressor only - Ext. year parts & labor CPE= Compressor only - Ext. year parts only CBE= Compressor only - Ext. year parts & labor CPE4= Compressor only - Ext. 4 year parts only CBE4= Compressor only - Ext. 4 year parts & labor CPE= Compressor only - Ext. year parts only CBE= Compressor only - Ext. year parts & labor CPE6= Compressor only - Ext. 6 year parts only CBE6= Compressor only - Ext. 6 year parts & labor CPE7= Compressor only - Ext. 7 year parts only CBE7= Compressor only - Ext. 7 year parts & labor CPE8= Compressor only - Ext. 8 year parts only CBE8= Compressor only - Ext. 8 year parts & labor CPE9= Compressor only - Ext. 9 year parts only CBE9= Compressor only - Ext. 9 year parts & labor NNNN= None - no extended compressor warranty 4 Extended Compressor Warranty EPE= Entire Unit - Ext. year parts only EBE= Entire Unit - Ext. year parts & labor EPE= Entire Unit - Ext. year parts only EBE= Entire Unit - Ext. year parts & labor EPE= Entire Unit - Ext. year parts only EBE= Entire Unit - Ext. year parts & labor EPE4= Entire Unit - Ext. 4 year parts only EBE4= Entire Unit - Ext. 4 year parts & labor EPE= Entire Unit - Ext. year parts only EBE= Entire Unit - Ext. year parts & labor EPE6= Entire Unit - Ext. 6 year parts only EBE6= Entire Unit - Ext. 6 year parts & labor EPE7= Entire Unit - Ext. 7 year parts only EBE7= Entire Unit - Ext. 7 year parts & labor EPE8= Entire Unit - Ext. 8 year parts only EBE8= Entire Unit - Ext. 8 year parts & labor EPE9= Entire Unit - Ext. 9 year parts only EBE9= Entire Unit - Ext. 9 year parts & labor NNNN= None - no extended unit warranty Extended Refrigeration Warranty RA= year R-4a refrigerant RA= year R-4a refrigerant RA= year R-4a refrigerant RA4= 4 year R-4a refrigerant RA= year R-4a refrigerant RA6= 6 year R-4a refrigerant RA7= 7 year R-4a refrigerant RA8= 8 year R-4a refrigerant RA9= 9 year R-4a refrigerant RAT= 0 year R-4a refrigerant NNN= None - no extended refrigerant warranty 6 Delay Warranty Start D00= Additional Months: 0 [ - 8] D0= Additional Months: [ - 0] D04= Additional Months: 4 [ - ] D06= Additional Months: 6 [ - 4] D08= Additional Months: 8 [ - 6] D0= Additional Months: 0 [ - 8] D= Additional Months: [ - 0] 7 Always NN 8 Standard / Seismic Construction NN= Standard Construction SM= Seismic Construction 9 Unit- Misc. S= Standard Unit X= Special Unit 40 Revision 00= Latest Revision 4 Condenser Leaving Water Temperature (LWT) 0000= Condenser Leaving Water Temperature (Ex.:. 400= 40 F) 4 Percentage of Glycol, Evaporator 000 = None E00= Ethylene Percentage (Ex.: E0 = 0% Ethylene) P00= Propylene Percentage (Ex.: P0 = 0% Propylene) 4 Percentage of Glycol, Condenser 000 = None E00= Ethylene Percentage (Ex.: E0 = 0% Ethylene) P00= Propylene Percentage (Ex.: P0 = 0% Propylene) Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 6

7 Electrical Legend Schem. Sym. Description Location ABR Alarm Bell Relay Field Mounted CB - 6 Circuit Breaker Control Box CFS Condenser Flow Switch Field Mounted CHWI Chilled Water Flow Indicator Field Mounted CHWR, Chilled Water Relay Field Mounted COMPR- 6 Compressors Below Control Box CP Unit Controller Control Box CT- GFI, Ground Fault Sensor Control Box CWPR, Condenser Water Pump Relay Field Mounted DS Disconnect Switch Control Box EXV, EXV Electronic Expansion Valve Liquid Line EXB Expansion Board Control Box EXVB Electronic Expansion Valve Driver Board Control Box FSW Flow Switch Field Mounted FU4, Control Fuses, Primary Control Box FU6 Control Fuse, Secondary Control Box GF, Ground Fault Protection Control Box GND Ground Control Box HCS Heat/Cool Switch Control Box HP, High Pressure Switch Discharge Line HPR, High Pressure Relay Control Box HTR- 6 Compressor Heaters On Compressor M- 6 Compressor Contactors Control Box MP- 6 Motor Protection On Compressor OL- 6 Overloads Control Box PD, Power Block Control Box PVM, Phase Voltage Monitor Control Box PS, Pumpdown Switch Side of Control Box RSS Remote Stop Switch Field Mounted S System Shut-Off Switch Side of Control Box S00 Leaving Water Temperature Sensor Evaporator S0, Suction Pressure Transducer Suction Line S0, 4 Discharge Pressure Transducer Discharge Line S0 Entering Condenser Temperature Sensor Condenser S08 Entering Water Temperature Sensor Condenser S0 Leaving Condenser Temperature Sensor Condenser S, Suction Temperature Sensor Suction Line S4, Liquid Temperature Sensor Liquid Line SR, Liquid Line Solenoid Relay Control Box SV, Liquid Line Solenoids Liquid Line SV, 6 Hot Gas Bypass Solenoids Hot Gas Bypass Line T Control Transformer Control Box T- T 4V Control Transformers Control Box TIB Terminal Interface Board Control Box TB- Terminal Blocks Control Box Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 7

8 Typical Unit Layout Diagrams Top View 4 4 B Side View A Ref. No. Description Location A Compressors- Circuit # Refrigeration Section B Compressors- Circuit # Refrigeration Section Tubing- Suction, Discharge, Hot Gas, Liquid lines Refrigeration Section Evaporator Refrigeration Section 4 Filter Drier Refrigeration Section Expansion Valve Refrigeration Section 6 Condenser Refrigeration Section 7 Condenser Relief Valves Refrigeration Section 8 Condenser Shut Off Valves (pc. behind Control Box) Refrigeration Section 9 Condenser Outlet Connection Refrigeration Section 0 Condenser Inlet Connection Refrigeration Section Control Box Control Box Section MicroTech II User Interface (CP) Control Box Section Main Disconnect Switch (DS) Control Box Section Four Compressor (080-00B), Right Hand (Code 0= R), 4 Pass (Code = 4), Packaged Unit (Code 0= W) configuration shown. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 8

9 Refrigeration Section Piping Schematics TGZ040-0B TGZ0-90B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 9

10 Refrigeration Section Compressors, Evaporator, & Condenser TGZ B (Control Box removed for clarity.) Circuit # Circuit # 4 A A Unit Size Ref Part Part No. Description Number, Compressor- Circuit # see next page Crankcase Heater 7670 A Switch- High Pressure- Circuit # , 4 Compressor- Circuit # see next page Crankcase Heater 7670 A Switch- High Pressure- Circuit # Evaporator 690 Single Insulation Kit (Code 06= S) Evaporator 690 Single Insulation Kit (Code 06= S) 7760 Evaporator 690 Single Insulation Kit (Code 06= S) Well, Sensor- Evaporator Condenser Assembly 4 Pass 678 Condenser Assembly Pass 6770 Condenser Assembly 4 Pass 678 Condenser Assembly Pass 6770 N/S= Not Shown on Diagram. Condenser components are listed on page following Discharge Line components. Code = 4. Code =. 040B 00B 060B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 0

11 Refrigeration Section Compressors, Sound Blankets TGZ040B, 00B, 060B Unit Size 040B 00B 060B Ref Part Part No. Description Number, Compressors - Circuit # 0890 Compressors - Circuit # 0890 Compressors - Circuit # Compressors - Circuit # 90 Compressors - Circuit # 90 Compressors - Circuit # 904 Compressors - Circuit # 940 Compressors - Circuit # 940 Compressors - Circuit # , 4 Compressors - Circuit # 0890 Compressors - Circuit # 0890 Compressors - Circuit # Compressors - Circuit # 90 Compressors - Circuit # 90 Compressors - Circuit # 904 Compressors - Circuit # 940 Compressors - Circuit # 940 Compressors - Circuit # N/S Sound Blanket Kit (C0= WS) 7766 N/S= Not Shown on Diagram. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

12 Refrigeration Section Compressors, Evaporator, & Condenser TGZ080-0B (Control Box removed for clarity.) Circuit # Circuit # 4 A A Unit Size Ref Part Part No. Description Number, Compressor- Circuit # see next page Crankcase Heater 7670 Crankcase Heater 7670 A Switch- High Pressure- Circuit # , 4 Compressor- Circuit # see next page Crankcase Heater 7670 Crankcase Heater 7670 A Switch- High Pressure, Circuit # Evaporator 6904 Evaporator 690 Evaporator 6907 Evaporator Well- Sensor, Evaporator Condenser Assembly 4 Pass 679 Condenser Assembly Pass 680 Condenser Assembly 4 Pass 679 Condenser Assembly Pass 680 Condenser Assembly 4 Pass 680 Condenser Assembly Pass 6800 N/S= Not Shown on Diagram. Condenser components are listed on page following Discharge Line components. Code = 4. Code =. 080B 00B 0B 0B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

13 Refrigeration Section Compressors, Sound Blankets TGZ080-0B Unit Size 080B 00B 0B 0B Ref Part Part No. Description Number, Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # 0008 Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # 0660 Compressors - Circuit # 0660 Compressors - Circuit # 00090, 4 Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # 0008 Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # 0660 Compressors - Circuit # 0660 Compressors - Circuit # N/S Sound Blanket Kit (C0= WS) 7766 Sound Blanket Kit (C0= WS) 7766 N/S= Not Shown on Diagram. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

14 Refrigeration Section Compressors, Evaporator, & Condenser TGZ0-90B (Control Box removed for clarity.) Circuit # A Circuit # A Unit Size Ref Part Part No. Description Number Compressors- Circuit # see next page Crankcase Heater 7670 A Switch- High Pressure, Circuit # Compressors- Circuit # see next page Crankcase Heater 7670 A Switch- High Pressure, Circuit # Evaporator Assembly 690 Evaporator Assembly Condenser Assembly 4 Pass 68 Condenser Assembly Pass Condenser Assembly 4 Pass 68 Condenser Assembly Pass Condenser Assembly 4 Pass 68 Condenser Assembly Pass N/S= Not Shown on Diagram. Condenser components are listed on page following Discharge Line components. Evaporator components are listed on page following Condenser Components. Code = 4. 4 Code =. 0B 70B 90B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

15 Refrigeration Section Compressors, Sound Blankets TGZ0B, 70B, 90B (Control Box removed for Circuit # clarity.) 6 4 Circuit # Unit Size 0B 70B 90B Ref Part Part No. Description Number,, Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # 0660 Compressors - Circuit # 0660 Compressors - Circuit # 00090, 4, 6 Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # Compressors - Circuit # 0660 Compressors - Circuit # 0660 Compressors - Circuit # Compressors - Circuit # 0660 Compressors - Circuit # 0660 Compressors - Circuit # N/S Sound Blanket Kit (C0= WS) N/S Sound Blanket Kit (C0= WS) N/S Sound Blanket Kit (C0= WS) N/S= Not Shown on Diagram. For Compressors, contact Daikin Applied with model and serial number information so that the correct compressor(s) can be identified. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

16 Refrigeration Section Compressor Trio Piping TGZ0B, 70B, 90B 0 Discharge Line Oil Equalization Suction Line Unit Size Ref. Part Part No. Description Number - Discharge Line Assembly 8860 Nut- Rotolock, Discharge Line 0060 Fitting- Rotolock, Discharge Line.7" 0070 Seal- Teflon, Discharge Line Oil Equalization Line Assembly 8860 Nut- Rotolock, Oil Equalization 0060 Fitting- Rotolock, Oil Equalization.7" 0070 Seal- Teflon, Oil Equalization N/S Sight Glass- Oil Equalization Suction Line Assembly HP Compressor HP Compressor Rotolock, Suction Line Fitting Kit, HP Compressor." Fitting, 0 HP Compressor." Coupling- Rotolock, HP Compressor 0090 Gasket Kit, HP Compressor A-66 Gasket, 0 HP Compressor 000 N/S= Not Shown on Diagram. Quantity is for ONE Trio arrangement. Each unit has two () Trios. Kit contains Flange, Gasket, and 4 Bolts. Contained in Rotolock Fitting Kit D 70D 00D Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 6

17 Refrigeration Section Liquid Line TGZ B Unit Size Ref. Part Part No. Description Number 0, 0 Valve- TXV 6T Valve- TXV T , 0 Sight Glass N/S Indicator only- Sight Glass , 07 Valve- Liquid Line Solenoid (SV, ) 7660 N/S Cable- Liquid Line Solenoid Meters , 09 Valve- Schrader , 0 Valve- Core , Valve- Cap , Shell- Filter Drier , 4 Core- Filter Drier , Gasket Kit- Filter Drier , 7 Valve- Angle.88" 07400, Tube, Sensor N/S= Not shown on diagram. The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 040B 00B 060B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 7

18 Refrigeration Section Liquid Line TGZ080-0B Unit Size Ref. Part Part No. Description Number 0, 0 Valve- TXV Ton Valve- TXV 40 Ton Valve- TXV 46 Ton , 0 Sight Glass , 07 Valve- Liquid Line Solenoid (SV, ) 7660 N/S Cable- Liquid Line Solenoid Meters , 09 Valve- Schrader , 0 Valve- Core , Valve- Cap , Shell- Filter Drier , 4 Core- Filter Drier , Gasket Kit- Filter Drier , 7 Valve- Angle." , Tube, Sensor N/S= Not shown on diagram. The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 080B 00B 0B 0B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 8

19 Refrigeration Section Liquid Line TGZ0-90B Unit Size Ref. Part Part No. Description Number 0, 0 Valve- EXV , 0 Saddle- Sight Glass , 06 Cap- Sight Glass , 07 Valve- Liquid Line Solenoid (SV, ) N/S Cable- Liquid Line Solenoid Meters , 09 Valve- Schrader , 0 Valve- Core , Valve- Cap , Shell- Filter Drier , 4 Core- Filter Drier , Gasket Kit- Filter Drier , 7 Valve- Angle.7" , Tube, Sensor N/S= Not shown on diagram. The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 0D 70D 00D Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 9

20 Refrigeration Section Hot Gas Bypass: (Code 4= HG) TGZ040-0B 0 Unit Size Ref. Part Part No. Description Number 0, Valve- Hot Gas Solenoid (SV, 6).88" 0860 Valve- Hot Gas Solenoid (SV, 6)." 0860 Coil Only- Hot Gas Solenoid 4V N/S Cable- HGBP Solenoid Meters N/S= Not shown on diagram. The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 040B 00B 060B 080B 00B 0B 0B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 0

21 Refrigeration Section Hot Gas Bypass: (Code 4= HG) TGZ0-90B Front View (Circuit #.) 0 Rear View (Circuit #.) Unit Size Ref. Part Part No. Description Number 0, Valve- Hot Gas Solenoid (SV, 6)." 0860 Coil Only- Hot Gas Solenoid 4V N/S Cable- HGBP Solenoid Meters N/S= Not shown on diagram. The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 070D 080D 090D Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

22 Refrigeration Section Suction Line TGZ B Unit Size Ref Part Part No. Description Number Valve- Schrader Valve- Core Valve- Cap Valve- Charge Coupling- Half Valve- Relief Tube- Sensor The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 040B 00B 060B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

23 Refrigeration Section Suction Line TGZ080-0B Unit Size Ref Part Part No. Description Number Valve- Schrader Valve- Core Valve- Cap Valve- Charge Coupling- Half Valve- Relief Tube- Sensor The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 080B 00B 0B 0B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

24 Refrigeration Section Suction Line TGZ0-90B Unit Size Ref Part Part No. Description Number Valve- Schrader Valve- Core Valve- Cap Valve- Charge Coupling- Half Valve- Relief Tube- Sensor The quantity listed is for the UNIT. The components listed in the table apply to either circuit. 0B 70B 90B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

25 Refrigeration Section Discharge Line TGZ B Unit Size Ref. Part Part No. Description Number 0, 0 Valve- Ball.7" , 09 Valve- Check.7" , Valve- Schrader , Valve- Core , Valve- Cap , 0 Flange Kit 70640, Adapter , Screw- Flange The quantity listed is for the UNIT. Equal quantities are used on each circuit. Flange Kit includes four (4) screws which are not used with the unit. Use screws Ref #, (079787) instead. 040B 00B 060B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

26 Refrigeration Section Discharge Line TGZ080-0B TGZ 080-0B shown TGZ0B Circuit # and TGZ0B Circuit #, Detail Unit Size Ref Part Part No. Description Number 0, 0 Valve- Ball.6" Valve- Ball." , 09 Valve- Check.6" Valve- Check." , Valve- Schrader , Valve- Core , Valve- Cap , 4 Coupling , Valve- Relief 40 PSI , 0 Flange Kit 70640, Adapter , Screw- Flange The quantity listed is for the UNIT. Flange Kit includes four (4) screws which are not used with the unit. Use screws Ref #, (079787) instead. Circuit #. 4 Circuit #. 080B 00B 0B 0B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 6

27 Refrigeration Section Discharge Line TGZ0-90B A 0A Discharge Circuit # (TGZ70-90B shown) Unit Size Ref. Part Part No. Description Number 0, 0 Valve- Ball." , 08 Valve- Check." , Valve- Schrader , Valve- Core 06400, Valve- Cap , 4 Coupling 70474, Valve- Relief 40 PSI , 0 Flange 940 0A, 0A Gasket- Flange 07099, Adapter , Screw- Flange The quantity listed is for the UNIT. Circuit # only. 0B 70B 90B Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 7

28 Refrigeration Section Condenser Components Ref. Description Part Qty. No. Number 0 Gasket- Head TGZ B 0" TGZ080-0B 4" 8780 TGZ0-90B 6" Valve- Condenser Shut Off Valve- Condenser Relief Cap- Condenser Shut Off Valve For Condenser components not listed, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 8

29 Refrigeration Section Shell and Tube Evaporator Components TGZ0-90B Side View Head End View 4 Ref. Description Part Qty. No. Number Bolt- Head E Gasket- Head E4440 Gasket- Distributor E4440 Ferrule- Suction E Flange- Suction E O'Ring- Suction E446 Bolt- Suction E40 8 Ferrule- Liquid E Flange- Liquid E O'Ring- Liquid E Bolt- Liquid E Well- Sensor E Plug Valve- Ball Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 9

30 Refrigeration Section Water Flow Switch: (Code = AA or BB) TGZ040-0B A TGZ0-90B A Unit Size Ref. Part Part No. Description Number Pipe Assy- Evaporator (Code = AA or BB) 9800 Clamp- Evaporator (Code = AA or BB) 9790 Flow Switch- Evaporator (Code = AA or BB) 0740 A Flow Switch- Condenser (Code = BB) 0740 N/S Cable- Flow Switch Meters 0740 N/S Cable- Flow Switch 0 Meters 0740 N/S= Not shown on diagram. Quantity of one cable PER switch. Determine length required before ordering. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 0

31 Control Box Control Box Layout Diagrams & Data Nameplate Control Box Layout Diagrams TGZ 040-0B TGZ 0-90B Control Box Data Nameplate Control Box Serial No. "S" + Year + ##### + Detail # Control Box Part Number For Control Box components not listed on the following pages, contact Daikin Applied with the COMPLETE Control Box Serial Number and Control Box Part Number as shown in the above sample label. This label is located inside the Control Box at the top of the panel. The above diagrams show typical Control Box Layouts. Control Box layouts vary depending upon unit options selected. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

32 Control Box Common Control Box Components Schem. Part Part Qty. Sym. Description Number CP Controller 068 TIB Converter Board- Transducer Terminal Block- Converter Board Pole CT-GF, Ground Fault Kit- Single Point (Code 0= F AND Code 8= PC, DC, DH) 00 Ground Fault Kit- Multiple Point (Code 0= F AND Code 8= MN, MH) 00 EXB Expansion Board EXVB Electronic Expansion Valve Board TGZ0-90B only GF, Ground Fault Relay 00 HCS Heat/Cool Switch HP, Switch- High Pressure HPR, Relay- Motor Protection PS, Switch- Pump Down PVM Phase Voltage Monitor /460V 000 Phase Voltage Monitor S00 Sensor- Evaporator Leaving Temperature 0' Lead Length, 0K S0 Sensor- Condenser Entering Temperature 0' Lead Length, 0K S08 Sensor- Evaporator Entering Temperature 0' Lead Length, 0K S0 Sensor- Condenser Leaving Temperature 0' Lead Length, 0K S, Sensor- Suction Temperature 0' Lead Length, 0K S4, Sensor- Liquid Temperature 0' Lead Length, 0K S Switch- Unit Shut Off SR, Relay- Liquid Line Solenoid Base- Relay, Liquid Line Solenoid For Control Box components not listed, contact Daikin Applied with the COMPLETE Control Box Serial Number and Control Box Part Number as shown in the sample label on the previous page. This label is located inside the Control Box at the top of the panel. The Controller (Main Control Board CP) must be programmed in order to function correctly. When ordering a replacement CP, provide the unit model and serial number so the unit specific software code can be loaded before shipment. Not shown on diagram. Schem. Description Part Qty. Sym. Number Transducers for units built through August 07 * S0,0 Transducer- Low Pressure 0768 S0,04 Transducer- High Pressure Circuit # N/S Cable for Transducers, 0 ft. (includes Boot) N/S Cable for Transducers, 6 ft. (includes Boot) N/S Cable for Transducers, 0 ft. (includes Boot) N/S Cable for Transducers, ft. (includes Boot) N/S Boot for Transducer Cable (black) Transducers for units built beginning September 07 * S0,0 Transducer- Low Pressure Circuit # 990 S0,04 Transducer- High Pressure Circuit # 990 N/S Cable for Transducers, 0 ft. (includes Boot) N/S Cable for Transducers, 6 ft. (includes Boot) N/S Cable for Transducers, 0 ft. (includes Boot) N/S Cable for Transducers, ft. (includes Boot) N/S Boot for Transducer Cable (blue) N/S = Not Shown * For units built in August 07, check the color of the Transducer Cable Boot. If Boot is black, use the parts above for through August 07. If Boot is blue, use the parts above for beginning September 07. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

33 Control Box Transformers & Fuses Transformers: T- Schem. Part Part Qty. Sym. Description Number T Transformer, Control 000VA, Transformer, Control 000VA, 80/400V Transformer, Control 000VA, 460V Transformer, Control 000VA, 600V Transformer, Control 00VA, Transformer, Control 00VA, 80/400V Transformer, Control 00VA, 460V Transformer, Control 00VA, 600V T- Transformer, 4V Control 00VA 0V to 4V TGZ040-0B units NORMALLY have 000VA T Transformers and TGZ0-90B units NORMALLY have 00VA T Transformers installed. Confirm VA of Transformer BEFORE ordering. Quantity varies depending upon unit size and options selected. Fuses: FU4-6 Schem. Part Part Qty. Sym. Description Number FU4, Fuse- Control Transformer, Primary 000VA@ 08V Fuse- Control Transformer, Primary 000VA@ 0V Fuse- Control Transformer, Primary 000VA@ Fuse- Control Transformer, Primary 000VA@ 400V Fuse- Control Transformer, Primary 000VA@ 460V Fuse- Control Transformer, Primary 000VA@ Fuse- Control Transformer, Primary 00VA@ 08V Fuse- Control Transformer, Primary 00VA@ 0V Fuse- Control Transformer, Primary 00VA@ Fuse- Control Transformer, Primary 00VA@ 400V Fuse- Control Transformer, Primary 00VA@ 460V Fuse- Control Transformer, Primary 00VA@ FU6 Fuse- Control Transformer, Secondary 00V Fuse- Control Transformer, Secondary 00V Fuse FU4-6 VA is dependent upon T Transformer VA. Confirm VA of Transformer T BEFORE ordering. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

34 Control Box Components for Units Without Compressor Overloads: (Code = NONE) TGZ B Unit Size 040B 00B 060B Schem. Part Part Sym. Description Number Power Block- Single Point PD Power Block 80A Power Block 7A Power Block- Multiple Point PD, Power Block 7A Disconnect Switch- Single Point DS Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Disconnect Switch- HSCCR 4 0A Mechanism- 0A, HSCCR Shaft- 0A, HSCCR 0004 Handle- 0A, HSCCR Disconnect Switch- Multiple Point DS, Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Compressor Contactor M- 4 Contactor 7A Contactor 6A Contactor 0A Contactor 40A Contactor A Contactor A Compressor Motor Protector CB- 4 Circuit Breaker 00A Circuit Breaker 70A Circuit Breaker 0A Circuit Breaker 40A Circuit Breaker A Single Point Connection Code 8= PC, DC, DH. Multiple Point Connection Code 8= MN, WN. Std. Single Connection Point Code 8= PC, DC. 4 HSCCR (High Short Circuit Current Rating) Single Point Connection Code 8= DH. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

35 Control Box Components for Units Without Compressor Overloads: (Code = NONE) TGZ080-0B Unit Size 080B 00B 0B 0B Schem. Part Part Sym. Description Number Power Block- Single Point PD Power Block 760A Power Block 80A Power Block 7A Power Block- Multiple Point PD, Power Block 80A Power Block 7A Disconnect Switch- Single Point DS Disconnect Switch- Std. 600A Mechanism- 600A, Std Shaft- 600A, Std Handle- 600A Std Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Mechanism- A, Std Shaft- A, Std Handle- A, Std Disconnect Switch- HSCCR 4 0A Mechanism- 0A, HSCCR Shaft- 0A, HSCCR 0004 Handle- 0A, HSCCR Disconnect Switch- Multiple Point DS Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Single Point Connection Code 8= PC, DC, DH. Multiple Point Connection Code 8= MN, WN. Std. Single Connection Point Code 8= PC, DC. 4 HSCCR (High Short Circuit Current Rating) Single Point Connection Code 8= DH. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page

36 Control Box Components for Units Without Compressor Overloads: (Code = NONE) TGZ080-0B, Continued Unit Size 080B 00B 0B 0B Schem. Part Part Sym. Description Number Disconnect Switch- Multiple Point, Cont. DS Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Compressor Contactor M, Contactor A Contactor 00A Contactor 7A Contactor 6A Contactor 0A Contactor 40A Contactor A M, 4 Contactor A Contactor 00A Contactor 7A Contactor 6A Contactor 0A Contactor 40A Contactor A Compressor Motor Protector CB, Circuit Breaker 00A Circuit Breaker 0A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A Circuit Breaker 0A CB, 4 Circuit Breaker 00A Circuit Breaker 0A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A Circuit Breaker 0A Multiple Point Connection Code 8= MN, WN. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 6

37 Control Box Components for Units Without Compressor Overloads: (Code = NONE) TGZ0-90B Unit Size 0B 70B 90B Schem. Part Part Sym. Description Number Power Block- Single Point PD Power Block 760A Power Block 80A Power Block- Multiple Point PD Power Block 80A Power Block 7A PD Power Block 80A Power Block 7A Disconnect Switch- Single Point DS Disconnect Switch- Std. 800A Mechanism- 800A, Std Shaft- 800A, Std Handle- 800A Std Disconnect Switch- Std. 600A Mechanism- 600A, Std Shaft- 600A, Std Handle- 600A Std Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Multiple Point DS Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Single Point Connection Code 8= PC, DC. DH. Multiple Point Connection Code 8= MN, WN. Std. Single Connection Point Code 8= PC, DC. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 7

38 Control Box Components for Units Without Compressor Overloads: (Code = NONE) TGZ0-90B, Continued Unit Size 0B 70B 90B Schem. Part Part Sym. Description Number Disconnect Switch- Multiple Point, Cont. DS Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Compressor Contactor M,, Contactor A Contactor 00A Contactor 7A Contactor 6A Contactor 0A Contactor 40A M, 4, 6 Contactor A Contactor 00A Contactor 7A Contactor 6A Contactor 0A Contactor 40A Compressor Motor Protector CB,, Circuit Breaker 00A Circuit Breaker 0A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A CB, 4, 6 Circuit Breaker 00A Circuit Breaker 0A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A Multiple Point Connection Code 8= MN, WN. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 8

39 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ B Unit Size 040B 00B 060B Schem. Part Part Sym. Description Number Power Block- Single Point PD Power Block 80A Power Block 7A Power Block- Multiple Point PD, Power Block 7A NA Disconnect Switch- Single Point DS Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Disconnect Switch- HSCCR 4 0A Mechanism- 0A, HSCCR Shaft- 0A, HSCCR 0004 Handle- 0A, HSCCR Disconnect Switch- Multiple Point DS, Disconnect Switch- Std. A Disconnect Switch- Std. 00A NA Mechanism- 00 & A, Std NA Shaft- 00 & A, Std NA Handle- 00 & A, Std NA Compressor Contactor M- 4 Contactor 7A Contactor 6A Contactor 0A Contactor 40A Contactor A Contactor A NA= Not available. Single Point Connection Code 8= PC, DC, DH. Multiple Point Connection Code 8= MN, WN. Std. Single Connection Point Code 8= PC, DC. 4 HSCCR (High Short Circuit Current Rating) Single Point Connection Code 8= DH. 4pc. for 08V ONLY. 6 4pc. for 0V ONLY. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 9

40 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ B, Continued Unit Size 040B 00B 060B Schem. Part Part Sym. Description Number Compressor Motor Protector CB- 4 Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A Circuit Breaker 0A Circuit Breaker 40A Circuit Breaker 0A Circuit Breaker A Compressor Overloads OL- 4 Overload 90-80A Overload - 66A Overload 0-40A pc. for 08V ONLY. 4pc. for 0V ONLY. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 40

41 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ080-0B Unit Size 080B 00B 0B 0B Schem. Part Part Sym. Description Number Power Block- Single Point PD Power Block 80A Power Block 7A Power Block- Multiple Point PD Power Block 80A Power Block 7A PD Power Block 80A Power Block 7A Disconnect Switch- Single Point DS Disconnect Switch- Std. 600A Mechanism- 600A, Std Shaft- 600A, Std Handle- 600A Std Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 6 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- A, Std Shaft- A, Std Handle- A, Std Disconnect Switch- HSCCR 4 0A Mechanism- 0A, HSCCR Shaft- 0A, HSCCR 0004 Handle- 0A, HSCCR Disconnect Switch- Multiple Point DS Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. 6 A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Single Point Connection Code 8= PC, DC, DH. Multiple Point Connection Code 8= MN, WN. Std. Single Connection Point Code 8= PC, DC. 4 HSCCR (High Short Circuit Current Rating) Single Point Connection Code 8= DH. pc. for 08V ONLY. 6 pc. for 0V ONLY. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

42 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ080-0B, Continued Unit Size 080B 00B 0B 0B Schem. Part Part Sym. Description Number Disconnect Switch- Multiple Point, Cont. DS Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Compressor Contactor M, Contactor A Contactor 00A Contactor 7A Contactor 6A Contactor 0A Contactor 40A Contactor A M, 4 Contactor A Contactor 00A Contactor 7A Contactor 6A Contactor 0A Contactor 40A Contactor A Multiple Point Connection Code 8= MN, WN. pc. for 08V ONLY. pc. for 0V ONLY. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

43 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ080-0B, Continued Unit Size 080B 00B 0B 0B Schem. Part Part Sym. Description Number Compressor Motor Protector CB, Circuit Breaker 7A Circuit Breaker A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A Circuit Breaker 0A Circuit Breaker 40A CB, 4 Circuit Breaker 7A Circuit Breaker A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 70A Circuit Breaker 60A Circuit Breaker 0A Circuit Breaker 40A Compressor Overloads OL, Overload 90-80A Overload - 66A Overload 0-40A OL, 4 Overload 90-80A Overload - 66A Overload 0-40A pc. for 08V ONLY. pc. for 0V ONLY. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

44 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ0-90B Unit Size 0B 70B 90B Schem. Part Part Sym. Description Number Power Block- Single Point PD Power Block 760A Power Block 80A Power Block 7A Power Block- Multiple Point PD, Power Block 80A Power Block 7A Disconnect Switch- Single Point DS Disconnect Switch- Std. 800A Mechanism- 800A, Std Shaft- 800A, Std Handle- 800A Std Disconnect Switch- Std. 600A Mechanism- 600A, Std Shaft- 600A, Std Handle- 600A Std Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Multiple Point DS Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Single Point Connection Code 8= PC, DC. DH. Multiple Point Connection Code 8= MN, WN. Std. Single Connection Point Code 8= PC, DC. 4 pc. for 08V ONLY. pc. for 0V ONLY. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 44

45 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ0-90B, Continued Unit Size 0B 70B 90B Schem. Part Part Sym. Description Number Disconnect Switch- Multiple Point, Cont. DS Disconnect Switch- Std. 400A Mechanism- 400A, Std Shaft- 400A, Std Handle- 400A Std Disconnect Switch- Std. 0A Mechanism- 0A, Std Shaft- 0A, Std Handle- 0A Std Disconnect Switch- Std. A Disconnect Switch- Std. 00A Mechanism- 00 & A, Std Shaft- 00 & A, Std Handle- 00 & A, Std Compressor Contactor M,, Contactor A Contactor 00A Contactor 6A Contactor 0A Contactor 40A M, 4, 6 Contactor A Contactor 00A Contactor 6A Contactor 0A Contactor 40A Multiple Point Connection Code 8= MN, WN. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 4

46 Control Box Components for Units With Compressor Overloads: (Code = WTOL) TGZ0-90B, Continued Unit Size 0B 70B 90B Schem. Part Part Sym. Description Number Compressor Motor Protector CB,, Circuit Breaker 7A Circuit Breaker A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 60A Circuit Breaker 0A CB, 4, 6 Circuit Breaker 7A Circuit Breaker A Circuit Breaker 00A Circuit Breaker 80A 0004 Circuit Breaker 60A Circuit Breaker 0A Compressor Overloads OL,, Overload 90-80A Overload - 66A Overload 0-40A OL, 4, 6 Overload 90-80A Overload - 66A Overload 0-40A Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 46

47 Control Box Communication Modules 60 BACnet with IP/Ethernet Module Ref. Description Part Qty. No. Number 60 BACnet IP/Ethernet Installation Kit BACnet MS/TP Communications Module Ref. Description Part Qty. No. Number 700 BACnet MS/TP Installation Kit MODBUS Communications Module Ref. Description Part Qty. No. Number 87 MODBUS Installation Kit LonMark Communications Module Ref. Description Part Qty. No. Number 90 LonMark Installation Kit Note that these Installation Kits can be used to replace an existing Communication Module, to change communication protocol, or to add communication capability to a unit that does not currently have a Communication Module installed. Each Installation Kit includes the Communication Module and Installation instructions. Templifier Scroll Compressor Water Heater, TGZ Vint. B Rev. F /7 RPL / Page 47

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016 Replacement Parts List No. 7000900 Revision E 04/06 McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage A To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com

More information

Air Cooled Scroll Compressor Condensing Unit

Air Cooled Scroll Compressor Condensing Unit Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature

More information

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62) Replacement Parts List No. 700026200 Revision E 05/2017 Daikin McQuay Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit AWS 400-550 Vintage B Unit Revision 0B (Code 62) To find your Daikin Applied

More information

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012 Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin Navigator. Water-Cooled Screw Compressor Chiller. WWV JNNS, MNNS, RNNS Vintage A. Replacement Parts List No Revision A 02/2018

Daikin Navigator. Water-Cooled Screw Compressor Chiller. WWV JNNS, MNNS, RNNS Vintage A. Replacement Parts List No Revision A 02/2018 Replacement Parts List No. 700053400 Revision A 02/2018 Daikin Navigator Water-Cooled Screw Compressor Chiller WWV JNNS, MNNS, RNNS Vintage A To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ 190, 210, 225, , 211, 226, 241 Vintage E Unit Revision 00

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ 190, 210, 225, , 211, 226, 241 Vintage E Unit Revision 00 Replacement Parts List No. 7000500 Revision K 02/208 Daikin Trailblazer Air-Cooled Scroll Chiller AGZ 90, 20, 225, 240 9, 2, 226, 24 Vintage E Unit Revision 00 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A Replacement Parts List No. 700014100 Revision P 05/2017 Daikin McQuay Pathfinder Air Cooled Chiller Screw Compressor Two Circuit AWS 150-405 Vintage A For units built after 8/1/11, contact Daikin Applied

More information

Daikin Daikin McQuay. Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit. AWS Vintage: C Unit Revision 00 (Code 62)

Daikin Daikin McQuay. Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit. AWS Vintage: C Unit Revision 00 (Code 62) Replacement Parts List No. 700028200 Revision J 10/2018 Daikin Daikin McQuay Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit AWS 170-410 Vintage: C Unit Revision 00 (Code 62) To find your Daikin

More information

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988 Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin

More information

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000 Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787

More information

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018 Replacement Parts List No. 700014900 Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018 Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS Vintage DS, DM, DE, DF. Replacement Parts List No Revision K 04/2016

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS Vintage DS, DM, DE, DF. Replacement Parts List No Revision K 04/2016 Replacement Parts List No. 700006600 Revision K 04/2016 McQuay Global Air-Cooled Screw Compressor Chiller AGS 225-450 Vintage DS, DM, DE, DF To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design

More information

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018 Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-(

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating and Maintenance Manual OMM 1130 Group: Chiller Part Number: OMM 1130 Effective: March 2012 Supercedes: November 2011 Water-Cooled Scroll Compressor Chillers WGZ030DW to WGZ200DW, Packaged Water-Cooled

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017 Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993 Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017 Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating Manual OM WGZC-2 Group: Chiller Part Number: 331975301 Effective: August 2011 Supercedes: November 2010 Water-Cooled Scroll Compressor Chillers WGZ 030CW To WGZ 200CW, Packaged Water-Cooled Chiller

More information

Templifier Heat Recovery Water Heaters

Templifier Heat Recovery Water Heaters Installation Manual IM 1137-3 Group: Chiller Part Number: IM1137-3 Effective: July 2017 Supersedes: August 2015 Templifier Heat Recovery Water Heaters TGZ040B to TGZ190B, Packaged Water Heater 600 to 3100

More information

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016 Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017 Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018 Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2) Replacement Parts List No. 057117200 Revision G 08/2016 McQuay Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E WCDD, WCDE, WCMG 019-060 Design A (1) WCDD, WCDE 019-060 Design B (2) To find

More information

TABLE OF CONTENTS ! DANGER. Dangers indicate a hazardous situation which will result in death or serious injury if not avoided. !

TABLE OF CONTENTS ! DANGER. Dangers indicate a hazardous situation which will result in death or serious injury if not avoided. ! Installation Manual IM 1137 Group: Chiller REV Part Number: IM1137 Effective: October 2011 Supersedes: New Templifier Heat Recovery Water Heaters TGZ040B to TGZ190B, Packaged Water Heater 0 to 3100 MBH

More information

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015 Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4) Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993 Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998 Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,

More information

Daikin McQuay. Centrifugal Chiller Single Compressor WSC, TSC, HSC 079. Replacement Parts List No Revision H 11/2016

Daikin McQuay. Centrifugal Chiller Single Compressor WSC, TSC, HSC 079. Replacement Parts List No Revision H 11/2016 Replacement Parts List No. 700000400 Revision H /206 Daikin McQuay Centrifugal Chiller Single Compressor WSC, TSC, HSC 079 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating Manual OM WGZ-2 Group: Chiller Part Number: 331374501 Effective: March 2005 Supercedes: OM WGZ-1 Water-Cooled Scroll Compressor Chillers WGZ 030AW To WGZ 120AW, Packaged Water-Cooled Chiller

More information

Water-Cooled Scroll Compressor Chillers

Water-Cooled Scroll Compressor Chillers Operating Manual OM WGZC Group: Chiller Part Number: 331374501 Effective: January 2008 Supercedes: New Water-Cooled Scroll Compressor Chillers WGZ 030CW to WGZ 200CW, Packaged Water-Cooled Chiller WGZ

More information

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier eplacement Parts List No. 000000 evision F 09/06 McQuay oofpak Condensing Unit Medium Cabinet, Standalone CS 050-05 Tons Vintage C Code = A, A Valid f units built 06/00 & Earlier To find your Daikin Applied

More information

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017 Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994 Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787

More information

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007 Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied

More information

IM Installation and Maintenance Manual. Templifier Heat Recovery Water Heaters

IM Installation and Maintenance Manual. Templifier Heat Recovery Water Heaters Installation and Maintenance Manual Templifier Heat Recovery Water Heaters IM 1137-4 Group: Chiller Part Number: IM1137-4 Date: June 2018 Supersedes: July 2017 Model TGZ, B Vintage 600 to 3100 MBH HFC-134a

More information

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018 Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or

More information

Water-Cooled Screw Compressor Chillers

Water-Cooled Screw Compressor Chillers Operating Manual OM WGS-5 Water-Cooled Screw Compressor Chillers WGS 130AW to WGS 190AW, Packaged Water-Cooled Chiller WGS 130AA to WGS 190AA, Chiller with Remote Condenser 120 to 200 Tons, 420 to 700

More information

Daikin McQuay. Centrifugal Chiller Dual Compressor WDC, TDC, HDC 048, 050. Last Manufactured: 2007

Daikin McQuay. Centrifugal Chiller Dual Compressor WDC, TDC, HDC 048, 050. Last Manufactured: 2007 Replacement Parts List No. 70000000 Revision L 2/207 Daikin McQuay Centrifugal Chiller Dual Compressor WDC, TDC, HDC 048, 050 Last Manufactured: 2007 To find your Daikin Applied parts distributor, call

More information

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

SUBMITTAL DATA BAYVIEW SENIOR CENTER. City of Pensacola. for. Sold to. Prepared for. Air-Tech / Darren Wood. Job Number: AZIK4A.

SUBMITTAL DATA BAYVIEW SENIOR CENTER. City of Pensacola. for. Sold to. Prepared for. Air-Tech / Darren Wood. Job Number: AZIK4A. SUBMITTAL DATA for BAYVIEW SENIOR CENTER Sold to Prepared for City of Pensacola Job Number: AZIK4A Customer PO#: Prepared by Air-Tech / Darren Wood 6/6/2018 Job Name: BAYVIEW SENIOR CENTER 2 of 25 www.daikinapplied.com

More information

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,

More information

RECORD SUBMITTAL COVER SHEET

RECORD SUBMITTAL COVER SHEET RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AQUASNAP AIR-COOLED CHILLER CH-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

SERVICE PARTS for ECO353N

SERVICE PARTS for ECO353N T-60PL Manual SERVICE PARTS for ECO5N Models Y50-50 & Y50-50 T-60PL REV. 0/0 0 Mobile Climate Control TABLE Of CONTENTS INTRODUCTION... i CONFIGURATION IDENTIFICATION... i OPTION DESCRIPTION... i ORDERING

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Air-Cooled Scroll Compressor Chiller Operation Manual OM AGZC-1 Group: Chiller Part Number: 331376301 Effective: February 2010 Supercedes: April 2009 AGZ 030CH through 190CH, Packaged AGZ 030CB through

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

MDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6

MDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6 This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing parts to be sure that this is the correct parts list. There have been several

More information

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5 This is the list of service parts for the MDT2C12A-1A and MDT2C12A-1B ice maker dispensers. The B series model began in late 2014. It has a number of electrical differences from the prior model. Always

More information

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978 Replacement Parts List No. 055224800 Revision C 10/2017 McQuay Aircon Air Cooled Condenser AMB, APB 020-140 AMD, APD 008-030 Vintage A Last Manufacture: 1978 To find your Daikin Applied parts distributor,

More information

Water-Cooled Screw Compressor Chillers

Water-Cooled Screw Compressor Chillers Water-Cooled Screw Compressor Chillers Catalog 617-4 WGS 130AW To WGS 190AW, Packaged Water-Cooled Chiller WGS 130AA To WGS 190AA, Chiller with Remote Condenser 120 to 200 Tons, 420 to 700 kw R-134A, 60

More information

NEW CHILLER SCHEDULE

NEW CHILLER SCHEDULE TITLE: REPLACE CHILLER MACC MAXIMO # 4542690 PROJECT # 14M108CN MACC # 14-0459 ATTACHMENTS: 1. MAXIMO Equipment update form SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

Water-Cooled Screw Compressor Chillers

Water-Cooled Screw Compressor Chillers Catalog Cat WGS Water-Cooled Screw Compressor Chillers WGS 130AW To WGS 190AW, Packaged Water-Cooled Chiller WGS 130AA To WGS 190AA, Chiller with Remote Condenser 120 to 200 Tons, 420 to 700 kw R-134A,

More information

Installation Manual IM

Installation Manual IM Installation Manual IM 1128-1 Group: Chiller Part Number: 331375601 REV: 01 Effective: April 2012 Supersedes: February 2012 WSC, WME and WMC-B Centrifugal Chillers Reassembly of Knockdown Shipments COMPRESSOR

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Air-Cooled Screw Compressor Chillers

Air-Cooled Screw Compressor Chillers Catalog Cat AGSD-1 Air-Cooled Screw Compressor Chillers Models AGS 225D to AGS 450D 210 to 450 Tons, 740 to 1580 kw Packaged or with Remote Evaporator or Chilled Water Pump Package R-134a, Hz Engineered

More information

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Product Data. Features/Benefits. 19XB Positive Pressure Storage System Product Data 19XB Positive Pressure Storage System 19XB028 Copyright 1992 Carrier Corporation 19XB052 Carrier s Positive Pressure Storage (PPS) System ensures the critical conservation of refrigerants

More information

Installation Instructions

Installation Instructions . AquaSnap 30MPA,MPW015-071 Liquid Chillers with Scroll Compressors and ComfortLink Controls 50/60 Hz Installation Instructions CONTENTS Page GENERAL........................................ 1 SAFETY CONSIDERATIONS.....................1,2

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13 Water cooled water chillers from 200 kw to 1550 kw Screw Compressor Serie: Series: Emissione: Issue: LCWX Catalogo: Leaflet: Sostituisce: Supersedes: DE 56 01/16 12/13 Index Identification code Index...

More information

Wiring Diagrams Units Produced After April 20, 2009

Wiring Diagrams Units Produced After April 20, 2009 UNIT 38AH 0-034 Wiring Diagrams Units Produced After April 20, 2009 (Includes Variable Air Volume ModuPanel Control) ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/-3-60, 460-3-60 575-3-60 380-3-60-3-50, 380/415-3-50

More information

Water-Cooled Scroll Compressor Chiller

Water-Cooled Scroll Compressor Chiller Installation and Maintenance Manual IM 1131-4 Water-Cooled Scroll Compressor Chiller Group: Chillers Part Number: IM1131-4 Date: July 2017 WGZ030DW - WGZ200DW, Packaged Water-Cooled Chillers WGZ030DA -

More information

Liebert Datamate: R-407C Parts Manual

Liebert Datamate: R-407C Parts Manual Liebert Datamate: R-407C Parts Manual While every precaution has been taken to ensure accuracy and completeness in this manual, Vertiv Co. asssumes no responsibility, and disclaims all liability for damages

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Installation, Operation and Maintenance Manual IOMM AGZ-5 Group: Chiller Part Number: 330411801 Effective: October 2004 Supercedes: IOMM AGZ-4 Air-Cooled Scroll Compressor Chiller AGZ 026B through 130B

More information

Illustrated Parts List REFRIGERATED BACK COUNTER. Duke Manufacturing Company. MODEL: RBC 48 RBC 60 (Ending Serial # , Built 3/24/2017)

Illustrated Parts List REFRIGERATED BACK COUNTER. Duke Manufacturing Company. MODEL: RBC 48 RBC 60 (Ending Serial # , Built 3/24/2017) Illustrated Parts List RBC 60 RBC 48 REFRIGERATED BACK COUNTER MODEL: RBC 48 RBC 60 (Ending Serial # 03172774, Built 3/24/2017) This manual is Copyright 2018 Duke Manufacturing Co. All rights reserved.

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

Spare Parts Catalogue MV1006

Spare Parts Catalogue MV1006 Spare Parts Catalogue MV1006 1 - UNIT PANELS - AIR COOLED 2 - UNIT PANELS - WATER COOLED 3 - REFRIGERANT SYSTEM - AIR COOLED - UP TO S.N. 00462 4 - REFRIGERANT SYSTEM - AIR COOLED - FROM S.N. 00463 TO

More information

Air-Cooled Scroll Compressor Chiller

Air-Cooled Scroll Compressor Chiller Installation, Operation, and Maintenance Manual IOM 1206-1 Air-Cooled Scroll Compressor Chiller Group: Chillers Part Number: IOM1206-1 Date: May, 2014. AGZ030EH - AGZ070EH, Packaged Chillers R-410A, 50/60

More information

Installation Instructions

Installation Instructions 30GTN015-035 Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION.................................1-11

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS W-150-H-P-*D-PP Vertical Dual Refrigeration Circuit Scroll Compressors R410a Refrigerant Nominal Size 12 Ton Non-Reversing (Heating OR Cooling) Commercial Hydronic Geothermal

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

Air-Cooled Scroll Compressor Water Chillers

Air-Cooled Scroll Compressor Water Chillers Installation, Operation and Maintenance Manual IOMM AGZ1-2 Group: Chiller Part Number: 331373801 Effective: February 2005 Supersedes: IOMM AGZ1-1 Air-Cooled Scroll Compressor Water Chillers AGZ 010A AGZ

More information

Parts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH hoshizakiamerica.com Number: 71357 Issued: 11-19-2014 Revised: 11-28-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

R- 410A Series Zero Ozone Depletion

R- 410A Series Zero Ozone Depletion Form: WR-GS-0705 GENERAL SPECIFICATION Compact Connectable Reversing 10-30HP Water to Water Geothermal Heat Pump R- 410A Series Zero Ozone Depletion Chiller Solutions LLC, 2008 General Description The

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions Installation, Start-Up and Service Instructions GEMINI 38ARZ007-012, 38ARS008-012 38ARD012-024, 38AKS014-024 Air-Cooled Condensing Units 50/60 Hz CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

GeneSys. Air-Cooled Screw Compressor Chillers. Catalog

GeneSys. Air-Cooled Screw Compressor Chillers. Catalog Catalog Cat AGS-2 GeneSys Air-Cooled Screw Compressor Chillers Models AGS 120C to AGS 210C 110 to 210 Tons, 420 to 740 kw Packaged and with Remote Evaporator R-134a, 60 Hz Engineered for flexibility and

More information

Air-Cooled Global Chiller

Air-Cooled Global Chiller Product Manual PM 970 Group: Chiller Effective: June 1997 Supersedes: None Air-Cooled Global Chiller Type AGR 055AS through 100AS Reciprocating Compressor with R-22 60 hertz 1997 McQuay International Table

More information