1 EEDE06-9 technical data Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW50-300

2 Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. ISO400 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin units comply with the European regulations that guarantee the safety of the product. Zandvoordestraat 300 B Ostend Belgium EEDE06-9 EEDE /2006 Printed in Belgium by Goekint Graphics

3 EEDE06-9 technical data Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW50-300

4 l l t i l Chillers R-40A ALTHERMA er A e 0 h 4 -h R AC Cooling only Heating only Heat pump 4 Altherma Chillers

5 Outdoor units R-40A ERYQ TABLE OF CONTENTS ERYQ Features Specifications Nominal Capacity and Nominal Input Technical Specifications Electrical Specifications Capacity tables Cooling/Heating capacity tables Dimensional drawing & centre of gravity Dimensional drawing Centre of gravity Piping diagram Wiring diagram Wiring diagram External connection diagram Sound data Sound pressure spectrum Operation range Altherma Outdoor units 5

6 Outdoor units R-40A ERYQ Altherma Outdoor units 6 Features O u t d o o r u n i A l t h e r m a E R Y Q R A Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort

7 2 Specifications Outdoor units R-40A ERYQ 2- NOMINAL CAPACITY AND EKHBH* EKHBX* NOMINAL INPUT ERYQ005A ERYQ006A ERYQ007A ERYQ005A ERYQ006A ERYQ007A Indoor Units EKHBH007A* EKHBH007A* EKHBH007A* EKHBX007A* EKHBX007A* EKHBX007A* Condition Heating Minimum kw capacity Nominal kw Maximum kw Cooling Minimum kw capacity Nominal kw Maximum kw Heating PI Nominal kw Cooling PI Nominal kw COP Nominal EER Nominal Condition 2 Heating Minimum kw Nominal kw Maximum kw Cooling Minimum kw Nominal kw Maximum kw Heating PI Nominal kw Cooling PI Nominal kw COP Nominal EER Nominal Notes *Condition - cooling Ta 35 C - LWE 7 C - heating Ta DB/WB 7 C/6 C - LWC 35 C (DT = 5 C) * Condition 2 - cooling Ta 35 C - LWE 8 C (DT = 5 C) - heating Ta DB/WB 7 C/6 C - LWC 45 C (DT = 5 C) 2 ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) 2-2 TECHNICAL SPECIFICATIONS Casing Colour Ivory white Material Polyester painted galvanised steel Dimensions Unit Height mm 797 Width mm 960 Depth mm 390 Packing Height mm 735 Width mm 825 Depth mm 300 Weight Unit kg 56 Packed Unit kg 6 Packing Material EPS Carton Weight kg 5 Heat Dimensions Length mm 845 Exchanger Nr of Rows 2 Fin Pitch mm.8 Nr of Stages 32 Tube type Hi-Xa(8) Fin Type WF fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Quantity Motor Quantity Output W 53 Compressor Quantity Motor Model 2YC63BXD#C Type Hermetically sealed swing compressor Motor Output W 920 ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) Altherma Outdoor units 7

8 2 Specifications Outdoor units R-40A ERYQ TECHNICAL SPECIFICATIONS Operation Range Sound Level (nominal) Heating Min CWB -20 Max CWB 25 Cooling Min CDB 7 Max CDB 20 Sanitary water Min CDB -20 Max CDB 43 Heating Cooling Sound Power Sound Pressure Sound Power Sound Pressure dba dba dba dba Refrigerant Type R-40A Charge kg.7 Control Expansion valve(electronic type) Nr of Circuits Refrigerant Oil Type FVC50K Charged Volume l 0.75 Piping connections ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) Liquid (OD) Type Flare connection Diameter (OD) mm 6,35 Gas Type Flare connection Diameter (OD) mm 5,9 Drain Quantity Type Socket Diameter mm 8 (OD) Piping Length Minimum m 3 Maximum m 30 Additional Refrigerant Charge kg/m 0.02 IF > 0m Installation height difference Maximum m 5 ERYQ005A (+ EKHBX) Max. internunit level difference m 20 Defrost Method Reverse cycle Defrost Control Sensor for outdoor heat exchanger temperature Capacity Control Method Inverter controlled Standard Item Installation manual Accessories Quantity Item Drain plug Quantity ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX) 8 Altherma Outdoor units

9 Outdoor units R-40A ERYQ 2 Specifications ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) 2-3 ELECTRICAL SPECIFICATIONS Power Supply Name V Phase Frequency Hz 50 Voltage V Voltage range Maximum V +0% Current Starting Cooling A Current Heating A Wiring connections Maximum Cooling A 6.25 running Current Heating A 8 Recomended fuses A 20 For Power Supply For connection with indoor Quantity 3 Quantity 4 Remark Included earth wiring ERYQ007A (+ EKHBX) 2 Altherma Outdoor units 9

10 3 Capacity tables Outdoor units R-40A ERYQ 3 - Cooling/Heating capacity tables 3 COOLING Model Tamb ( C) LWE ( C) CC PI CC PI CC PI CC PI CC PI CC PI HEATING (Peak values) Model LWC Tamb HC PI HC PI HC PI HC PI HC PI HEATING (integrated values*) * The integrated heating capacity and power input, is the average heating capacity and power input during cycle. (from end of defrost till end of the next defrost). Model LWC Tamb HC PI HC PI HC PI HC PI HC PI TW5672-A CC HC PI LWE LWC Tamb SYMBOLS : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/ (kw) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/ (kw) : Power input (kw) : Leaving Water Evaporator temperature ( C) : Leaving Water Condensor temperature ( C) : Ambient temperature ( C) RH=85% NOTES Cooling capacity Capacity is according to Eurovent rating standard 6/C/ and valid for chilled water range Dt = 3 8 C 2 Heating capacity Capacity is according to Eurovent rating standard 6/C/ and valid for chilled water range Dt = 3 8 C 3 Power input Power input is total input according to Eurovent rating standard 6/C/ Altherma Outdoor units

11 Outdoor units R-40A ERYQ 4 Dimensional drawing & centre of gravity 4 - Dimensional drawing ERYQ Drain outlet (I.D. J 5.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than 200 unit (mm) 4 In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M0) Brand name label Name plate Wiring inlet Terminal strip with earth terminal Outdoor air thermistor Liquid stop valve (J6.4 CuT) Service port Gas stop valve (J5.9 CuT) 3D05658B Altherma Outdoor units

12 Outdoor units R-40A ERYQ 4 Dimensional drawing & centre of gravity 4-2 Centre of gravity 4 ERYQ The position of foundation bolt 4D042258G 2 Altherma Outdoor units

13 5 Piping diagram Outdoor units R-40A ERYQ ERYQ Outdoor unit Heat exchanger Outdoor temperature thermistor 5 Capillary tube Heat exchanger thermistor Capillary tube 2 Capillary tube 3 Muffler with filter Refrigerant flow Cooling Heating Capillary tube 4 Filter Propeller fan Motor operated valve Filter Four way valve on : heating Muffler with filter Muffler Muffler Liquid stop valve Field piping Field piping Discharge pipe thermistor Compressor Accumulator Gas stop valve with service port 3D052750A Altherma Outdoor units 3

14 6 Wiring diagram 6 - Wiring diagram Outdoor units R-40A ERYQ 6 ERYQ Power supply To indoor unit Sheet metal Indoor g Field wiring Outdoor (outdoor) (discharge) (Condenser) ZC Z7C : Ferrite core XM, X2M : Terminal strip YE : Electronic expansion valve coil V2, V3, V5, V9, V00 : Varistor SA2 : Surge arrester FU, FU2, FU3: : Fuse AC, AC2 U, V, W, XA, X2A E, E2 HR, HR2 : Connector MRM0, MRM20 MRC/W : Magnetic relay RT R3T : Thermistor S2 S02 : Connector LEDA : Pilot lamp L : Live N : Neutral SW : Forced operation on/off switch SW (SW) SW4 : Local setting SW (SW4) MC : Compressor motor MF : Fan motor LR : Reactor QL PM PCB,2 YR Sheet metal : Overload protector : Power module : Printed circuit board : Reversing solenoide valve coil : Terminal strip fixed plate 3D052296B 4 Altherma Outdoor units

15 Outdoor units R-40A ERYQ 6 Wiring diagram 6-2 External connection diagram EKHB-A Power supply Unit power supply: 230V + earth Backup heater power supply (3/6/9kW): 400V or 230V + earth 3 core XM:L-N-Earth Standard parts Outdoor unit For more details please check unit wiring diagram 6 Optional power supply X2M:-2-3-Earth Booster heater power supply (3kW): 400V or 230V + earth 4 core Optional parts 3 core 3 or 4 core Field supply XM:9-0--Earth Sanitary tank Power supply booster heater 5 core XM:7-8-Earth 4 core Room thermostat A3P (optional) Q2L - Clixon booster heater 230V or 400V NO valve: NC valve: 2 core 2 way valve M2S (EKHBX Units) for cooling mode R5T - Thermistor water temperature 2 core Signal Indoor unit 2 core 3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating Thermistor cable Note: min. distance to power cable = 3cm User interface 3TW Altherma Outdoor units 5

16 7 Sound data Outdoor units R-40A ERYQ 7 - Sound pressure spectrum 7 Sound pressure level (db) ERYQ005ABV3 Cooling Sound pressure level (db) ERYQ006ABV3 Cooling 3TW5677- Octave band center frequency (Hz) 3TW5677- Octave band center frequency (Hz) NOTES NOTES Data is valid at free field condition (measured in a semi-anachoic room) 2 db(a) = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone Data is valid at free field condition (measured in a semi-anachoic room) 2 db(a) = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone ERYQ007ABV3 Cooling ERYQ005ABV3 Heating Sound pressure level (db) Sound pressure level (db) 3TW5677- NOTES Octave band center frequency (Hz) 3TW NOTES Octave band center frequency (Hz) Data is valid at free field condition (measured in a semi-anachoic room) 2 db(a) = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone Data is valid at free field condition (measured in a semi-anachoic room) 2 db(a) = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone 6 Altherma Outdoor units

17 7 Sound data Outdoor units R-40A ERYQ 7 - Sound pressure spectrum Sound pressure level (db) ERYQ006ABV3 Heating Sound pressure level (db) ERYQ007ABV3 Heating 7 3TW NOTES Octave band center frequency (Hz) 3TW NOTES Octave band center frequency (Hz) Data is valid at free field condition (measured in a semi-anachoic room) 2 db(a) = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone Data is valid at free field condition (measured in a semi-anachoic room) 2 db(a) = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Coil Microphone Location of microphone Altherma Outdoor units 7

18 8 Operation range Outdoor units R-40A ERYQ 8 Outdoor temp. ( CDB) Cooling mode Leaving evaporator water temperature ( C) Outdoor temp. ( CDB) Heating mode Leaving condenser water temperature ( C) Outdoor temp. ( CDB) Sanitary mode : Booster heater operation only Leaving condenser water temperature ( C) 4TW5673-A 8 Altherma Outdoor units

19 Indoor units R-40A EKHBH / EKHBX TABLE OF CONTENTS EKHBH / EKHBX Features Specifications Technical Specifications Electrical Specifications Options Dimensional drawing & centre of gravity Dimensional drawing Piping diagram Wiring diagram Wiring diagram External connection diagram Hydraulic performance Static pressure drop unit Altherma Indoor units 9

20 Indoor units R-40A EKHBH / EKHBX Altherma Indoor units 20 Features 2 I n d o o r u n i t A l t h e r m a E K H B H / E K H R A Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort

21 2 Specifications Indoor units R-40A EKHBH / EKHBX EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) 2- TECHNICAL SPECIFICATIONS Outdoor units ERYQ005A ERYQ006A ERYQ007A ERYQ005A ERYQ006A ERYQ007A Nominal input (Indoor only) W 230 Casing Colour RAL900 Material Polyester painted galvanised steel Dimensions Packing Height mm 225 Width mm 660 Depth mm 595 Unit Height mm Width mm Depth mm Weight Unit kg Packed Unit kg Packing Material EPS Wood Carton PS(straps) Weight kg 0 Main components Pump Main components Water side Heat exchanger Main components Water circuit Pump Type Water cooled Nr. of speed 3 Nominal ESP Cooling kpa unit Heating kpa Pump Water side Heat exchanger Water flow rate Nom. Water side Heat exchanger Expansion vessel Water filter Power input W 30 Type Brazed plate Qty Water l 0.67 volume Water flow rate Min. l/min 2 Cooling l/min Heating l/min Insulation material Polyurethane foam Volume l 0 Max. water pressure bar 3 Pre pressure Diameter perforations bar mm Material Brass Piping connections inch "MBSP diameter Piping inch "MBSP Safety valve bar 3 Manometer Yes Drain valve / Fill valve Yes Shut off valve Yes Air purge valve Yes 2 2 Altherma Indoor units 2

22 2 Specifications Indoor units R-40A EKHBH / EKHBX TECHNICAL SPECIFICATIONS EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) Refrigerant Gas side diameter mm 5,9 Circuit Liquid side diameter mm (2) Sound Level Sound Pressure dba 27 Operation Waterside Cooling C 7 20 range Heating C Notes The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. ERYQ = 6.35 mm EKHB = 9.52 mm (flare connection) 22 Altherma Indoor units

23 Indoor units R-40A EKHBH / EKHBX 2 Specifications 2-2 ELECTRICAL SPECIFICATIONS EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A) Electric heater Type 3V3 Power Supply Phase Frequency Hz 50 Voltage V 230 Current Running Current A Electric heater Type 6V3 Power Supply Phase Frequency Hz 50 Voltage V 230 Current Running Current A 26 Electric heater Type 6W Power Supply Phase 3N Frequency Hz 50 Voltage V 400 Current Running Current A 8.6 Electric heater Type 6T Power Supply Phase 3 Frequency Hz 50 Voltage V 230 Current Running Current A 5 Electric heater Type 9W Power Supply Phase 3N Frequency Hz 50 Voltage V 400 Current Running Current A 3 Electric heater Type 9T Power Supply Phase 3 Frequency Hz 50 Voltage V 230 Current Running Current A 23 Altherma Indoor units 23

24 Indoor units R-40A EKHBH / EKHBX 3 Options 2 3 Optional equipment for EKHB(H/X)007* Reference Description Number Availability EKHBH007A9T EKHBX007A9T EKHBH007A9W EKHBX007A9W EKHBH007A6T EKHBX007A6T EKHBH007A6W EKHBX007A6W EKHBH007A6V3 EKHBX007A6V3 EKHBH007A3V3 EKHBX007A3V3 Heating only model Reversible model Available options 3V3 Back up heater 3kW 230 V V Factory mounted 6V3 Back up heater 6kW 230 V V Factory mounted 6W Back up heater 6kW V + N V Factory mounted 6T Back up heater 6kW V V Factory mounted 9W Back up heater 9kW V + N V Factory mounted 9T Back up heater 9kW V V Factory mounted Available kits EKSWW50V3 Sanitary warm water tank 50 l 230 V V V V V V V Kit EKSWW200V3 Sanitary warm water tank 200 l 230 V V V V V V V Kit EKSWW300V3 Sanitary warm water tank 300 l 230 V V V V V V V Kit EKSWW200Z2 Sanitary warm water tank 200 l 400 V V V Kit EKSWW300Z2 Sanitary warm water tank 300 l 400 V V V Kit EKWBSWW50 Wall bracket for EKSWW50V3 Kit 3TW Altherma Indoor units

25 Indoor units R-40A EKHBH / EKHBX 4 Dimensional drawing & centre of gravity 4 - Dimensional drawing EKHBH-A 2 4 Service door Minimum space for service & ventilation Min. 200 Center of gravity j Pump + switch for speed setting j2 Remocon j3 Water IN conection M BSP j4 Water OUT connection M BSP j5 Power supply intake (+ sanitary warm water tank) j6 Drain / fill valve j7 Air purge j8 Expansion vessel + nipple j9 Blow off valve j0 Pressure gauge j Water filter j2 Suction pipe connection J5.9 flare connection j3 Liquid pipe connection J9.52 flare connection j4 Shut off valves (delivered with unit) j5 Thermistor connection (+ sanitary warm water tank) j6 Holes for fixation j7 Blow off drain j8 Switchbox connection terminals j9 Wallbracket female BSP male BSP Min. 00 (Open) 553 (Closed) 36 A B Setup Setup Min TW5674-A EKHBX-A Service door Minimum space for service & ventilation Min. 200 Center of gravity j Pump + switch for speed setting j2 Remocon j3 Water IN conection M BSP j4 Water OUT connection M BSP j5 Power supply intake (+ sanitary warm water tank) j6 Drain / fill valve j7 Air purge j8 Expansion vessel + nipple j9 Blow off valve j0 Pressure gauge j Water filter j2 Suction pipe connection J5.9 flare connection j3 Liquid pipe connection J9.52 flare connection j4 Shut off valves (delivered with unit) j5 Thermistor connection (+ sanitary warm water tank) j6 Holes for fixation j7 Blow off drain / drain of drainpan j8 Switchbox connection terminals j9 Wallbracket female BSP male BSP Min. 25 (Closed) 46 (Open) 653 Dimensions wallbracket Min. 400 A B Setup Setup TW56724-A Altherma Indoor units 25

26 5 Piping diagram Indoor units R-40A EKHBH / EKHBX EKHB-A Water side 2 5 R4T R3T R2T RT Inlet water thermistor Refrigerant liquid side thermistor Outlet water backup heater thermistor Outlet water heat-exchanger thermistor Filter Field installation Shut off valve Inlet Refrigerant side Pressure gauge Drain valve Safety valve Drain Expansion vessel Cooling (EKHBX) Heating (EKHBX + EKHBH) Drain valve Option backup heater Pump Air purge Flowswitch Field installation Overview Electric heater body Shut off valve Outlet Outdoor unit Refr. out Refr. in Refr. in Refrigerant side Evaporator Condensor Water side Water inlet Water outlet Refr. out O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe PSpinned pipe 3TW Altherma Indoor units

27 6 Wiring diagram 6 - Wiring diagram EKHBH/X-A3V3 Indoor units R-40A EKHBH / EKHBX Power supply Outdoor unit Sanitary tank >> See note 2 << Only for EKSWW option 2 6 Only for EKHB*00*A3V3 or6v3 Only for EKSWW option Sanitary tank Only for EKSWW option Only for EKHB*00*A3V3 User interface Field wiring Thermostat On/Off Wiring dependent on model heating cooling supply from PCB Option Wire colour NO valve NC valve Only for EKHB*00*A6V3 Only for EKHB*00*A3V3 Only for EKSWW option Electric heater option fuse model 3V3 FB 20A EKSWW kit fuse model F2B 20A Notes: This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 not operate the unit short-circuiting protection devices Q2L, SL. Do by QL, 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet V2S : Spark suppression 2 VS : Spark suppression FU : Fuse 3.5A T 250V RT (A2P) : Thermistor (air) QDI : Earth leakage protector Q2L : Thermal protector booster heater QL : Thermal protector backup heater TR : Transformer 24V for PCB R5T : SWW Thermistor R4T : Inlet water thermistor R3T : Refrigerant liquid side thermistor R2T : Outlet water backup heater thermistor RT (AP) : Outlet water heat-exchanger thermistor SL : Flowswitch E4H : Booster heater E3H : Backup heater element 3 E2H : Backup heater element 2 EH : Backup heater element M3S : 3 way valve floorheating / sanitary warm water M2S : 2 way valve for cooling mode MP : Pump K3M : Contactor booster heater K2M : Contactor backup heater Step 2 KM : Contactor backup heater Step F2B : Fuse booster heater FB : Fuse backup heater A3P : Thermostat (field supply, PC = interval power circuit) A2P : Remocon PCB AP : Main PCB 3TW5676-4A EKHBH/X-A6V3 Power supply Outdoor unit Sanitary tank >>Seenote2<< Only for EKSWW option Only for EKSWW option Sanitary tank Only for EKSWW option User interface Field wiring Thermostat On/Off Wiring dependent on model heating cooling 230V AC supply from PCB Option Wire colour NO valve NC valve model FB model F2B Electric heater option fuse 6V3 32A EKSWW kit fuse 20A Only for EKSWW option Notes: This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 not operate the unit short-circuiting protection devices Q2L, SL. Do by QL, 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet XM : Terminal block V2S : Spark suppression 2 VS : Spark suppression FU : Fuse 3.5A T 250V RT (A2P) : Thermistor (air) QDI : Earth leakage protector Q2L : Thermal protector booster heater QL : Thermal protector backup heater TR : Transformer 24V for PCB R5T : SWW Thermistor R4T : Inlet water thermistor R3T : Refrigerant liquid side thermistor R2T : Outlet water backup heater thermistor RT (AP) : Outlet water heat-exchanger thermistor SL : Flowswitch E4H : Booster heater E3H : Backup heater element 3 E2H : Backup heater element 2 EH : Backup heater element M3S : 3 way valve floorheating / sanitary warm water M2S : 2 way valve for cooling mode MP : Pump K4M : Contactor backup heater K3M : Contactor booster heater K2M : Contactor backup heater Step 2 KM : Contactor backup heater Step F2B : Fuse booster heater FB : Fuse backup heater A3P : Thermostat (field supply, PC = interval power circuit) A2P : Remocon PCB AP : Main PCB 3TW Altherma Indoor units 27

28 6 Wiring diagram 6 - Wiring diagram EKHBH/X-A6W/9W Indoor units R-40A EKHBH / EKHBX Power supply Outdoor unit 2 6 >> See note 2 << Sanitary tank Only for EKSWW option Only for EKSWW option Sanitary tank Only for EKSWW*V3 Option Sanitary tank Only for EKSWW*Z2 Option Field wiring User interface Wiring dependent on model heating cooling Thermostat On/Off Option 230V AC supply from PCB Wire colour NO valve NC valve Electric heater option fuse model 6W 9W FB 3A 6A model F2B EKSWW kit fuse 20A Only for EKSWW option Notes: This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 not operate the unit short-circuiting protection devices Q2L, SL. Do by QL, 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet XM : Terminal block V2S : Spark suppression 2 VS : Spark suppression FU : Fuse 3.5A T 250V RT (A2P) : Thermistor (air) QDI : Earth leakage protector Q2L : Thermal protector booster heater QL : Thermal protector backup heater TR : Transformer 24V for PCB R5T : SWW Thermistor R4T : Inlet water thermistor R3T : Refrigerant liquid side thermistor R2T : Outlet water backup heater thermistor RT (AP) : Outlet water heat-exchanger thermistor SL : Flowswitch E4H : Booster heater E3H : Backup heater element 3 E2H : Backup heater element 2 EH : Backup heater element M3S : 3 way valve floorheating / sanitary warm water M2S : 2 way valve for cooling mode MP : Pump K4M : Contactor backup heater K3M : Contactor booster heater K3M : Contactor booster heater K2M : Contactor backup heater Step 2 KM : Contactor backup heater Step F2B : Fuse booster heater FB : Fuse backup heater A3P : Thermostat(Field supply) A2P : Remocon PCB AP : Main PCB 3TW5676-2B EKHBH/X-A6T/9T Power supply Outdoor unit >> See note 2 << Sanitary tank Only for EKSWW option Only for EKSWW option Sanitary tank Only for EKSWW option User interface Wiring dependent on model Field wiring Thermostat On/Off heating cooling Option Wire colour 230V AC supply from PCB NO valve NC valve Electric heater option fuse model 6T 9T FB 20A 32A model F2B EKSWW kit fuse 20A Only for EKSWW option Notes: This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 not operate the unit short-circuiting protection devices Q2L, SL. Do by QL, 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet XM : Terminal block V2S : Spark suppression 2 VS : Spark suppression FU : Fuse 3.5A T 250V RT (A2P) : Thermistor (air) QDI : Earth leakage protector Q2L : Thermal protector booster heater QL : Thermal protector backup heater TR : Transformer 24V for PCB R5T : SWW Thermistor R4T : Inlet water thermistor R3T : Refrigerant liquid side thermistor R2T : Outlet water backup heater thermistor RT (AP) : Outlet water heat-exchanger thermistor SL : Flowswitch E4H : Booster heater E3H : Backup heater element 3 E2H : Backup heater element 2 EH : Backup heater element M3S : 3 way valve floorheating / sanitary warm water M2S : 2 way valve for cooling mode MP : Pump K4M : Contactor backup heater K3M : Contactor booster heater K2M : Contactor backup heater Step 2 KM : Contactor backup heater Step F2B : Fuse booster heater FB : Fuse backup heater A3P : Thermostat(Field supply) A2P : Remocon PCB AP : Main PCB 3TW5676-3B 28 Altherma Indoor units

29 Indoor units R-40A EKHBH / EKHBX 6 Wiring diagram 6-2 External connection diagram EKHB-A Power supply Unit power supply: 230V + earth Backup heater power supply (3/6/9kW): 400V or 230V + earth 3 core Standard parts Outdoor unit XM:L-N-Earth For more details please check unit wiring diagram 2 6 Optional power supply X2M:-2-3-Earth Booster heater power supply (3kW): 400V or 230V + earth 4 core Optional parts 3 core 3 or 4 core Field supply XM:9-0--Earth Sanitary tank Power supply booster heater 5 core XM:7-8-Earth 4 core Room thermostat A3P (optional) Q2L - Clixon booster heater 230V or 400V NO valve: NC valve: 2 core 2 way valve M2S (EKHBX Units) for cooling mode R5T - Thermistor water temperature 2 core Signal Indoor unit 2 core 3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating Thermistor cable Note: min. distance to power cable = 3cm User interface 3TW Altherma Indoor units 29

30 Indoor units R-40A EKHBH / EKHBX 7 Hydraulic performance 7 - Static pressure drop unit 2 7 ESP = f (Flow) ESP [mh2o] Flow (l/min) I: low speed setting pump II: medium speed setting pump III: high speed setting pump ESP: External static pressure Flow: waterflow trough the unit Warning: Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrate in the technical specifications. 4TW Altherma Indoor units

31 Sanitary Hot Water R-40A EKSWW TABLE OF CONTENTS EKSWW Features Specifications Technical Specifications Electrical Specifications Selection data Dimensional drawing & centre of gravity Dimensional drawing Wiring diagram External connection diagram Altherma Sanitary Hot Water 3

32 o y a r a r t e0 i h n t4 al- Sanitary Hot Water R-40A EKSWW Features H m A W W S K ES A R Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort 3 32 Altherma Sanitary Hot Water

33 2 Specifications Sanitary Hot Water R-40A EKSWW 2- TECHNICAL SPECIFICATIONS EKSWW50V3 EKSWW200V3 EKSWW300V3 EKSWW200Z2 EKSWW300Z2 Casing Colour Neutral white Material Epoxy-coated mild steel Dimensions Packing Height mm Width mm Depth mm Unit Height mm Width mm Depth mm Weight Unit kg Packed Unit kg Packing Material EPS Carton Weight kg Main components Tank Water l volume Material Stainless steel (DIN.452) Max. temperat ure C 85 Max. water pressure bar 0 Tank Insulation Material Polyurethane foam Min. thickness mm 40 Main components Temperature sensor Piping connections Heat Quantity exchanger Material Stainless steel (DIN.440) Booster heater Quantity Capacity kw 3 Cable length m 2 Water inlet H/E Diameter inch 3/4" FBSP Water outlet H/E Diameter inch 3/4" FBSP Cold water in Diameter inch 3/4" FBSP Hot water out Diameter inch 3/4" FBSP ELECTRICAL SPECIFICATIONS EKSWW50V3 EKSWW200V3 EKSWW300V3 EKSWW200Z2 EKSWW300Z2 Unit Power Supply Phase 2 Frequency Hz Voltage V Nominal running current A Fuse Size A Phase 2 Altherma Sanitary Hot Water 33

34 3 Selection data Sanitary Hot Water R-40A EKSWW The ALTHERMA by Daikin heat-pump in combination with the optional sanitary tank provide hot water for household usage. The below mentioned data allow a proper selection of the sanitary tank size for maximum comfort and efficiency. 3 3 () Sanitary hot water volume: The volume of hot water available for domestic sanitary usage depends on the physical volume of the sanitary tank, on the sanitary water setpoint temperature and on the temperature spreading in the tank. Therefor we define the equivalent hot water volume (EHWV). Definition: EHWV = The volume of hot water available for domestic sanitary usage at a temperature of 40 C. 40 C is considered a comfortable sanitary hot water temperature. Tank Setpoint temp. Usage pattern EHWV (l) ( C) Modest Medium High L L L Grade ++ Excessive availability of sanitary hot water. + Sufficient availability of sanitary hot water. - Temporary shortage of sanitary hot water can occur. Usage pattern Modest Daily demand up tp 220 l -> typcial 2-persons usage pattern. Medium Daily demand up to 325 l -> typical 3 to 4 persons usage pattern. High Daily demand up to 550 l -> 4 to 6 persons usage pattern. (2) Heat-up time: Definition: Heat-up time The time required to reheat the sanitary tank to 55 C after tapping a certain volume of hot water at 40 C. note: changing the field settings (see installation manual) can influence the heat-up time. Tank Setpoint temp. Heat-up time for Heat-up time for 50 ( C) 50 L (bath) <min> L (shower) <min> 50L L L Conditions for testing: Ta = 7 CDB / 6 CWB, Troom = 20 C, Tstart = 0 C, outdoor unit type: ERYQ007 (3) Efficiency of sanitary hot water production: In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water. The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is. Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system. Definition: Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water. Heat-pump portion Setpoint temp. ( C) Conditions: Real life condition Simulation of a daily usage based upon medium usage pattern. Outdoor temperature 7 CDB / 6 CWB Room temperature 20 CDB Outdoor unit type ERYQ007 Tank type 200l Field settings Default field settings (see installation manual). 4TW Altherma Sanitary Hot Water

35 Sanitary Hot Water R-40A EKSWW 4 Dimensional drawing & centre of gravity 4 - Dimensional drawing EKSWW j Water mains in female 3/4 BSP j2 Water mains out female 3/4 BSP j3 Thermistor connection female /2 BSP j4 Flow (from hydrobox) female 3/4 BSP j5 Return (to hydrobox) female 3/4 BSP j6 Switchbox j7 Clixon j8 Connection female 3/4 BSP 3 4 3TW Altherma Sanitary Hot Water 35

36 Sanitary Hot Water R-40A EKSWW 5 Wiring diagram 5 - External connection diagram EKHB-A 3 5 Power supply Unit power supply: 230V + earth Backup heater power supply (3/6/9kW): 400V or 230V + earth Optional power supply Booster heater power supply (3kW): 400V or 230V + earth 3 core Standard parts Outdoor unit XM:L-N-Earth X2M:-2-3-Earth For more details please check unit wiring diagram 4 core Optional parts 3 core 3 or 4 core Field supply XM:9-0--Earth Sanitary tank Power supply booster heater 5 core XM:7-8-Earth 4 core Room thermostat A3P (optional) Q2L - Clixon booster heater 230V or 400V NO valve: NC valve: 2 core 2 way valve M2S (EKHBX Units) for cooling mode R5T - Thermistor water temperature 2 core Signal Indoor unit 2 core 3 way valve M3S (when EKSWW is installed) selection sanitary-floorheating Thermistor cable Note: min. distance to power cable = 3cm User interface 3TW Altherma Sanitary Hot Water

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW EEDEN07-721 technical data Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Altherma ERHQ011-016AA EKHBH007AC / EKHBX007AC EKSWW150-300 Daikin s unique position as a manufacturer of air conditioning

More information

EEDEN technical data ERHQ AA. Altherma. Altherma

EEDEN technical data ERHQ AA. Altherma. Altherma EEDEN08-720 technical data ERHQ0-06AA Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement

More information

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL EEDEN08-70 technical data Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Daikin s unique position as

More information

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL EEDEN08-70 technical data Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Altherma ERHQ006-008AD EKHBH/X008AA ERHQ0-06AA EKHBH/X06AB EKHWS(U) EKSOL Daikin s unique position as

More information

TABLE OF CONTENTS ERSQ-AAY1

TABLE OF CONTENTS ERSQ-AAY1 Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................

More information

EEDEN technical data ERHQ AA

EEDEN technical data ERHQ AA EEDEN08-70 technical data Altherma Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil

More information

TABLE OF CONTENTS ERHQ BAV3

TABLE OF CONTENTS ERHQ BAV3 TABLE OF CONTENTS ERHQ006-016BAV3 1 Features........................................................... 134 2 Specifications..................................................... 135 Nominal Capacity and

More information

TABLE OF CONTENTS EKHWS

TABLE OF CONTENTS EKHWS Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS TABLE OF CONTENTS EKHWS 1 Features............................................................ 68 2 Specifications......................................................

More information

EEDEN technical data. Altherma TM

EEDEN technical data. Altherma TM EEDEN09-720 technical data Altherma TM Altherma TM Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrige-rants has led to its close involvement in environmental

More information

EEDEN technical data EKRTR. Altherma. Altherma

EEDEN technical data EKRTR. Altherma. Altherma EEDEN08-720 technical data EKRTR Altherma Altherma Altherma Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental

More information

General Outline: Altherma

General Outline: Altherma ESIE08-0 General Outline: Altherma Stacked The illustration below shows the required installation and service space (mm). Do not stack more than one unit. +/- 00 mm is required as the dimension for laying

More information

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1 Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EBLQ-BB6W Monobloc with bottom plate heater EBLQ-BB6W TABLE OF CONTENTS EBLQ-BB6W Features.............................................................

More information

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3 Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EDHQ-BB6V3 Monobloc without bottom plate heater EDHQ-BB6V3 TABLE OF CONTENTS EDHQ-BB6V3 Features.............................................................

More information

technical data air conditioning systems Indoor Units FBQ-C7VEB

technical data air conditioning systems Indoor Units FBQ-C7VEB technical data Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features.............................................................

More information

Air Conditioners. Technical Data FBQ-C

Air Conditioners. Technical Data FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information

DESIGN MANUAL Version 1.0

DESIGN MANUAL Version 1.0 DESIGN MANUAL 2009 Version 1.0 TABLE OF CONTENTS Topic Type Page 1. Introduction 5 2. System Design 6 2.1 Components 6 2.2 Design Guidelines 7 2.2.1 Total Heat Demand 7 2.2.2 Inclusion of power supply

More information

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8 Air Conditioning Technical Data High temperature hydrobox for VRV EEDEN15-204 Indoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A Air Conditioners Technical Data Heating only hydrobox for VR V E E D E N 1 1-2 0 4 HXHD-A Air Conditioners Technical Data Heating only hydrobox for VR V E E D E N 1 1-2 0 4 HXHD-A TABLE OF CONTENTS HXHD-A

More information

EEDEN technical data EKSOLHWAV1

EEDEN technical data EKSOLHWAV1 EEDEN08-720 technical data Altherma EKSOLHWAV Altherma Solar Kit Features S o l a r K i t A l t h e r m a E K S O L H W A V S o l a r K i t 2 Specifications 2- TECHNICAL SPECIFICATIONS EKSOLHWAV Dimensions

More information

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air technical data RMXS-E7V3B1 Super multi plus air conditioning systems Split Sky Air Outdoor Units R-410A RMXS-E7V3B1 TABLE OF CONTENTS RMXS-E7V3B1 1 Features.............................................................

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

Heating. Technical Data EEDEN ERRQ-AY1

Heating. Technical Data EEDEN ERRQ-AY1 Heating Technical Data EEDEN3-726 ERRQ-AY Daikin Altherma high temperature split ERRQ-AY TABLE OF CONTENTS ERRQ-AY Features............................................................. 2 2 Specifications.......................................................

More information

TABLE OF CONTENTS RMXS-E8V1B

TABLE OF CONTENTS RMXS-E8V1B Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications.....................................................

More information

TABLE OF CONTENTS EBLQ01-016AA6V3

TABLE OF CONTENTS EBLQ01-016AA6V3 Monobloc EBLQ0-06AA6V TABLE OF CONTENTS EBLQ0-06AA6V Features............................................................. 2 2 Specifications....................................................... Nominal

More information

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1 Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CW Daikin Altherma low temperature split ERLQ-CW TABLE OF CONTENTS ERLQ-CW Features.............................................................

More information

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6 EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Sound pressure level Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Hydraulic components Anti freeze heater (optional) W 75 75 75 Expansion

More information

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air technical data FVXS-FV1B R-410A air conditioning systems Split Sky Air Indoor Units R-410A FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features.............................................................

More information

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A Air Conditioning Technical Data Low temperature hydrobox for VRV EEDEN3-204 HXY-A Indoor Unit Low temperature hydrobox for VRV HXY-A TABLE OF CONTENTS HXY-A Features.............................................................

More information

TABLE OF CONTENTS EDLQ AA6V3

TABLE OF CONTENTS EDLQ AA6V3 Monobloc EDLQ0-06AA6V3 TABLE OF CONTENTS EDLQ0-06AA6V3 Features............................................................. 2 2 Specifications....................................................... 3

More information

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E Air Conditioning Technical Data Multi model application EEDEN1-100 MXS-E TABLE OF CONTENTS MXS-E 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................

More information

TABLE OF CONTENTS EKHTS-A

TABLE OF CONTENTS EKHTS-A TABLE OF CONTENTS EKHTS-A 1 Features........................................................... 408 2 Specifications..................................................... 409 Technical Specifications...........................................

More information

Air Conditioning Technical Data RZAG-MV1

Air Conditioning Technical Data RZAG-MV1 Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN AZQS-BV1 Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data RZASG-MV1

Air Conditioning Technical Data RZASG-MV1 Air Conditioning Technical Data RZASG-MV1 Outdoor Unit RZASG-MV1 TABLE OF CONTENTS RZASG-MV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data FTXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................

More information

technical data air conditioning systems RZQ B8W1B Split Sky Air

technical data air conditioning systems RZQ B8W1B Split Sky Air technical data RZQ00-25-40B8WB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its

More information

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems Indoor Units FCQ-C8VEB technical data Indoor Units FCQ-C8VEB air conditioning systems technical data Indoor Units FCQ-C8VEB air conditioning systems TABLE OF CONTENTS FCQ-C8VEB! 1 Features.............................................................

More information

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data EEDEN RXS-F8 Air Conditioning Technical Data EEDEN15-100 RXS-F8 Outdoor Unit RXS-F8 TABLE OF CONTENTS RXS-F8 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1 Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1 Air Conditioning Technical Data EEDEN3-00 RZQSG-L(8)Y Outdoor Unit RZQSG-L(8)Y TABLE OF CONTENTS RZQSG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air technical data FHYP-B Ceiling Suspended Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and

More information

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

DACA-EEDEN technical data. Engineering Data. DaikinAltherma technical data Engineering Data DaikinAltherma Daikin Altherma Engineering Data Part 1: Overview 1. Daikin Altherma Overview... 1 1.1 Daikin Altherma Split System...1 1.2 Daikin Altherma Monobloc System...2

More information

Air Conditioners. Technical Data RZQG-L

Air Conditioners. Technical Data RZQG-L Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t

More information

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1 Air Conditioning Technical Data EEDEN-00 RZQSG-L(/8)V Outdoor Unit RZQSG-L(/8)V TABLE OF CONTENTS RZQSG-L(/8)V Features............................................................. 2 2 Specifications.......................................................

More information

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air EEDEN08-00 technical data RZQS7-40C7VB air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has

More information

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

Air Conditioners. Technical Data FTXS-G

Air Conditioners. Technical Data FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE

More information

EDUS Heat Pump - D-Series

EDUS Heat Pump - D-Series EDUS 04-740 - Heat Pump - D-Series Split-System Room Air Conditioners D-Series The Single Split Duct-Free System Heat Pump FTXS09DVJU FTXS12DVJU FTXS15DVJU FTXS18DVJU FTXS24DVJU RX09FVJU RX12FVJU RX15FVJU

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................

More information

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air Indoor Units R-40A FTXS-G2VB

More information

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air EEDEN09-00 technical data RZQ-DV air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to

More information

technical data air conditioning systems RZQ C7Y1B Split Sky Air

technical data air conditioning systems RZQ C7Y1B Split Sky Air technical data RZQ200-250C7YB air conditioning systems Split Sky Air Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin

More information

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air EEDEN09-00 technical data RZQS-DV air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to

More information

Daikin air conditioners for your home, shops, restaurants and offices

Daikin air conditioners for your home, shops, restaurants and offices Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction

More information

Air Conditioning Technical Data AZAS-MY1

Air Conditioning Technical Data AZAS-MY1 Air Conditioning Technical Data AZAS-MY1 Outdoor Unit AZAS-MY1 TABLE OF CONTENTS AZAS-MY1 1 Features............................................................. 2 2 Specifications.......................................................

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700

More information

Chillers. Technical Data. EWYD-BZ 250~580 kw

Chillers. Technical Data. EWYD-BZ 250~580 kw Chillers Technical Data A i r C o o l e d C h i l l e r w w w. d a i k i n. e u EWYD-BZ 250~580 kw Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on over 80 years experience in

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r u n i t - m u l t i m o d e l E E D E N 2-0 0 MXS-K TABLE OF CONTENTS MXS-K Features............................................................. 2 2 Specifications.......................................................

More information

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Seasonal efficiency, smart use of energy The EU wants to make people aware of what units

More information

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air technical data FT(Y)S-B Wall Mounted Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C Air Conditioning Technical Data Ceiling suspended unit EEDEN13-131 AHQ-C Indoor Unit AHQ-C TABLE OF CONTENTS AHQ-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

Water-cooled chillers Remote condenser chillers NEW

Water-cooled chillers Remote condenser chillers NEW Water-cooled chillers Remote condenser chillers NEW EWWD120-540MBYN EWLD120-540MBYN Applied systems Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data F l o o r s t a n d i n g u n i t E E D E N 2-0 0 FVQ-C Indoor Unit Floor standing unit FVQ-C TABLE OF CONTENTS FVQ-C Features.............................................................

More information

EWWD MBYN EWLD MBYN Applied systems

EWWD MBYN EWLD MBYN Applied systems Water-cooled chillers Remote condenser chillers EWWD120-540MBYN EWLD120-540MBYN Applied systems Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has

More information

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air technical data RR-B8V3B_RR-B8WB Pair, Twin, Triple Application air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors

More information

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant

More information

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1 Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Single Unit Air cooled chiller EUWA-KBZW TABLE

More information

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air conditioners, heating & cooling. for large spaces. air to air heat pumps.   FDQ-B Air conditioners, heating & cooling for large spaces CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDQ-B THE MOST ADVANCED CLIMATE CONTROL FOR LARGE SPACES The quality air conditoning of Daikin

More information

Fan Coil Units. Technical Data FWC-BT/BF

Fan Coil Units. Technical Data FWC-BT/BF Fan Coil Units Technical Data R o u n d f l o w c a s s e t t e E C D E N 1 2-4 0 0 FWC-BT/BF Fan Coil Units Technical Data R o u n d f l o w c a s s e t t e E C D E N 1 2-4 0 0 FWC-BT/BF Table of Contents

More information

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air technical data FH(Y)B-FK7 Concealed Ceiling Unit air conditioning systems Split Sky ir Split - Sky ir ISO14001 assures an effective environmental management system in order to help protect human health

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water High temperature heating system AIR TO WATER HEAT PUMPS Renovation - Heating - Domestic hot water Daikin Altherma Heat pumps The solution with an eye to the future Renovating your heating system and wanting

More information

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018 New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

Air conditioners, heating & cooling for the retailmarket and offices

Air conditioners, heating & cooling for the retailmarket and offices Air conditioners, heating & cooling for the retailmarket and offices floor standing unit air to air heat pumps www.daikin.eu FVQ-B MAXIMUM RELIABILITY, MINIMUM ENERGY USE Advanced climate systems in modern

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2 INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWS50BV EKHWS00BV EKHWS00BV EKHWS00BZ EKHWS00BZ 4 5 6 x x x 4x x + x 00 7 05 0 45 5 400 5 6 00 /4" FBSP 6 H 0 H4 H 0 H 0

More information

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump The natural hoice installer leaflet DAikin Altherma low temperature heat pump Best seasonal efficiencies, providing the highest savings on running costs excellent COP ratings for incentive and certification

More information

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-B Indoor Unit FDQ-B TABLE OF CONTENTS FDQ-B 1 Features.............................................................

More information

Air conditioners Cooling only

Air conditioners Cooling only Air conditioners Rooftop, an economical solution for medium to large spaces Plug and play for easy installation High efficiency Quick cooling Wide operation range Compact unit www.daikinme.com UAT-CGXY

More information

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Remote control infrared ARC433B76 ARC433A8 ARC433B69 Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air technical data FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data I n d o o r u n i t E E D E N - 3 ABQ-A Indoor Unit Concealed ceiling unit ABQ-A TABLE OF CONTENTS ABQ-A Features.............................................................

More information

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9) Air Conditioning Technical Data Flexi type unit EEDEN14-100 FLXS-B(9) Indoor Unit FLXS-B(9) TABLE OF CONTENTS FLXS-B(9) 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 4 FTXN-L Indoor Unit Wall mounted unit FTXN-L TABLE OF CONTENTS FTXN-L Features.............................................................

More information

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for shops,restaurants and offices Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing

More information

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V. Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin Europe

More information

w w w. d a i k i n. e u ATXS-E

w w w. d a i k i n. e u ATXS-E Daikin air conditioners for your home WALL MOUNTED UNIT ATXS-E w w w. d a i k i n. e u Daikin s stylishly elegant wall mounted Siesta unit will grace the dining, living or bedroom of any home. Siesta will

More information

Daikin Altherma Low Temperature monobloc heat pump

Daikin Altherma Low Temperature monobloc heat pump Information for installers Daikin Altherma Low Temperature monobloc heat pump The natural choice Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Our broad experience,

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3 Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-J3 TALE OF CONTENTS FTX-J3 1 Features............................................................. 2 2 Specifications.......................................................

More information

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant EWAT-B Multi scroll chiller with R-32 refrigerant First air cooled chiller with environmental friendly R-32 refrigerant Daikin, world s first company introducing a new generation of air cooled scroll chiller

More information