Manual de Instrucciones Rooftop Serie CLIMA CREATOR 50Hz
|
|
- Lindsay Ford
- 5 years ago
- Views:
Transcription
1 Manual de Instrucciones Rooftop Serie CLIMA CREATOR Hz Lea atentamente todo este manual antes de utilizar su nuevo equipo de aire acondicionado. Modelos: BSRC _ HWN-R IMPRESO EN PAPEL ECOLÓGICO
2 Contents. Product Lineup.... External Appearance.... Nomenclature.... Features.... Specifications Dimensional Drawings Wiring Diagrams Performance Data.... Electrical Data.... Fan performance data.... Refrigerant Cycle Diagram.... Operation Limit Installation Wired Controller.... Error Code Accessories Maintenance and Upkeep... 7 Appendix :... 8 Manufacture reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
3 ClimaCreator Series RA Rooftop Package Unit Hz. Product Lineup T application Nominal ton Model Function Air Outlet Power Supply. BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz 7. BSRC-7HWN-R Heat pump Side air supply 8~V-N-Hz BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz. BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz BSRC-HWN-R Heat pump Side air supply 8~V-N-Hz Note:Please refer to specification tables for accurate cooling or heating capacity with Kw or Btu/h unit.
4 ClimaCreator Series RA Rooftop Package Unit Hz. External Appearance.&7.Ton 8.&Ton.&Ton 7.&Ton &Ton
5 ClimaCreator Series RA Rooftop Package Unit Hz. Nomenclature B S R C- C W N- R C Product design sequence C: The third design A: The second design Omit: The first design Power supply R: 8~V,Ph,Hz Refrigerate type N:RA Omit for R Wired controller Function mode C:Cooling only E:Electric heater and cooling H:Heat pump Cooling capacity XXX: ton (.ton) XX:Btu/h Air outlet way C:Side air supply Rooftop package Silent Air BGH
6 ClimaCreator Series RA Rooftop Package Unit Hz. Features. High reliability and high efficiency Outstanding reliability BGH rooftop package units shall be factory assembled, internally wired, fully charged refrigerant and % run tested to check cooling and heating operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. The unit is provided with an integral weather resistant control panel. Multiple self-protecting functions guarantee the safety of unit and running perfectly: high-pressure protection, low-pressure protection, over-heat protection, over-current protection and so on. Reliable components Famous brand compressor, high IP class motor, reliable pressure switch. Excellent efficiency High efficiency scroll compressor; Enlarge the air inlet area space contribute a high efficiency. Durable construction Pre-painted exterior cabinet panels pass -hour Salt Spray Test for durability. Weather-resistant construction with capped seams and sloped top panels. G galvanized heavy gauge plate conforming to ASTM-A-, Zinc content of galvanized plate is 7 g/m. New fan duct design Optimized fan vane shape reduces pressure loss and im proves heat exchange efficiency.
7 Adjustable Pulley Through changing the working pitch diameter of the pulley mounted on driver shaft, in turn the revolutions per minute of the driven shaft will increase or decrease to change air volume. ClimaCreator Series RA Rooftop Package Unit Hz Well compressor control Compressor start-stop is controlled directly by the main control board. To prevent compressor start and stop frequently, when the unit first / re-power, the compressor will delay three minutes to start, when the indoor temperature is below the set temperature or mode conversion or system protection, the compressor will start after seven minutes delay. It has two-stage control for the system which has two compressors. The system will shut off one compressor in condition of part load. Compressor cycle duty operation When the set temperature and ambient temperature meet one compressor to start, for the first time to open compressor A, compressor B start next time, this extends the compressor's life span effectively.. Easy installation and service Design flexibility, easy to install New structure design, compact design, smaller body size, reduce transfer cost.; Rooftop or ground is selectable to install. Anywhere removable as requirement without fixed. Easy drainage External drainage port reserved, quickly and accurately connect the rubber drainage pipe. External pressure gauge ports The unit provide external pressure gauge ports, for convenient and fast checking without remove the panel.
8 ClimaCreator Series RA Rooftop Package Unit Hz Easy access doors Installer no need to enter inside of the door, only out-of-doors. Provide easy access to system components for maintenance and service. Removable access doors on the filter, fan motor, and control box sections. Control box Control box access panel Inner moter Low voltage connections All ports of low voltage wires are integrated in the PCB board,so it is easy and safe for the installer to wire. System self-diagnostic The system self-diagnostic function, press the check button, the LED displays the normal checking code. When the unit is in running with abnormal operation, the LED will display the error code.. Standard features/options/accessories Description Standard features Horizontal discharge Compressor crankcase heaters Evaporator fan-belt driven Evaporator fan motor-odp type(tefc type optional) Condenser fan-direct drive, propeller type(except ton) Condenser fan-direct drive, axial type(only ton) Condenser fan motor-totally enclosed air-over type Filter, Nylon Filter, aluminum(thickness mm) Compressor overload protection Low &high pressure switch Cooling & heating thermostat Condenser fan guard Condenser coil guard Wired controller KJR-B Wired controller KJR-B Wired controller KJR-B Drainage pipe Drainage outlet Snap ring Options (factory installed) Accessories (field installed)
9 . Specifications T application Nominal ton (Ton). 7. Model BSRC-HWN-R BSRC-7HWN-R BSRC-HWN-R Power Supply V,Ph,Hz 8~V,Ph,Hz 8~V,Ph,Hz 8~V,Ph,Hz Cooling Heating Cooling Capacity Btu/h 7 8 kw... Power Input kw Heating Capacity Btu/h 8 7 kw Power Input kw Max. input consumption kw 8... Max. current A Performance Indoor Coil Indoor fan Compressor Outdoor Coil Outdoor Fan Refrigerant Indoor fan air flow CFM 8 8 ESP Pa 8 8 EER Btu/h/W... COP Btu/h/W.8.. Number of rows Fin spacing Tube diameter mm... FPI 7 mm inch / / / Type FC Centrifugal FC Centrifugal FC Centrifugal Quantity Drive type Direct Direct Belt Motors quantity Motor model YDK7-E YDK7-E YE-L--.KW Type Scroll Scroll Scroll Quantity Model ZP7KCE-TFD- HCJTLC EDH-DG Brand Copeland Danfoss Hitachi Capacity Btu/h Refrigerant oil charge ml x Number of rows.. Fin spacing Tube diameter mm... FPI mm inch / / / Type Propeller Propeller Propeller Quantity Drive type Direct Direct Direct Motors quantity Motor model YDK-C YDK8-C YS-P Type RA RA RA Refrigerant volume kg.8.+. Refrigerant Control Piston Piston Piston Net Weight kg Gross Weight kg Net Dimension WxHxD mm 7x8x 7x8x 8x8x Packing WxHxD mm 7x87x 7x87x x8x Shipping Qty'Per '/'/'HQ //8 //8 8// Note: The data are based on the following conditions: Cooling: : Indoor Temperature.7 C(8 F) DB /. C(7 F) WB; - Outdoor Temperature C( F) DB. Heating and Power input: Indoor Temperature C(8 F) DB/ C( F) WB; - Outdoor Temperature 7 C(. F) DB/ C(.8 F) DB 7
10 ClimaCreator Series RA Rooftop Package Unit Hz Nominal ton (Ton). Model BSRC-HWN-R BSRC-HWN-R Power Supply V,Ph,Hz 8~V,Ph,Hz 8~V,Ph,Hz Cooling Heating Cooling Capacity Btu/h 8 kw.. Power Input kw..7 Heating Capacity Btu/h kw Power Input kw. 7. Max. input consumption kw.7. Max. current A 8.. Performance Indoor Coil Indoor fan Compressor Outdoor Coil Outdoor Fan Refrigerant Indoor fan air flow CFM 7 ESP Pa EER Btu/h/W..8 COP Btu/h/W.7. Number of rows Fin spacing Tube diameter mm.. FPI mm 7 7 inch / / Type FC Centrifugal FC Centrifugal Quantity Drive type Belt Belt Motors quantity Motor model YE-L--KW YE-M--KW Type Scroll Scroll Quantity Model ZPKCE-TFD-+ ZPKCE-TFD- ZPKCE-TFD-+ ZPKCE-TFD- Brand Copeland Copeland Capacity Btu/h Refrigerant oil charge ml + + Number of rows. Fin spacing Tube diameter mm.. FPI 7 mm 7 8 inch / / Type Propeller Propeller Quantity Drive type Direct Direct Motors quantity Motor model YDK-E YS- Type RA RA Refrigerant volume Kg Refrigerant Control Piston Piston Net Weight kg Gross Weight kg 7 Net Dimension WxHxD mm xx xx Packing WxHxD mm xx xx Shipping Qty'Per '/'/'HQ // // Note: The data are based on the following conditions: Cooling: : Indoor Temperature.7 C(8 F) DB /. C(7 F) WB; - Outdoor Temperature C( F) DB. Heating and Power input: Indoor Temperature C(8 F) DB/ C( F) WB; - Outdoor Temperature 7 C(. F) DB/ C(.8 F) DB. 8
11 ClimaCreator Series RA Rooftop Package Unit Hz Nominal ton (Ton) Model BSRC-HWN-R BSRC-HWN-R BSRC-HWN-R Power Supply V,Ph,Hz 8~V,Ph,Hz 8~V,Ph,Hz 8~V,Ph,Hz Cooling Heating Cooling Capacity Btu/h kw Power Input kw Heating Capacity Btu/h 8 kw Power Input kw..8. Max. input consumption kw. 8. Max. current A. 7. Performance Indoor Coil Indoor fan Compressor Outdoor Coil Outdoor Fan Refrigerant Indoor fan air flow CFM 88 ESP Pa 7 EER Btu/h/W... COP Btu/h/W..8 Number of rows Fin spacing Tube diameter mm... FPI mm inch / / / Type FC Centrifugal FC Centrifugal FC Centrifugal Quantity Drive type Belt Belt Belt Motors quantity Motor model YE-S--.KW YE-M--7.KW YE-M--7.KW Type Scroll Scroll Scroll Quantity Model ZPKCE-TFD- SHAALC* SH8AALC* Brand Copeland Danfoss Danfoss Capacity Btu/h 8 8 Refrigerant oil charge ml x x x Number of rows + + Fin spacing Tube diameter mm... FPI 7 mm inch / / / Type Propeller Propeller Propeller Quantity Drive type Direct Direct Direct Motors quantity Motor model YS-- YS-- YS-- Type RA RA RA Refrigerant volume kg Refrigerant Control Piston Capillary Capillary Net Weight kg Gross Weight kg Net Dimension WxHxD mm x7x7 xx xx Packing WxHxD mm x8x x7x x7x Shipping Qty'Per '/'/'HQ /7/ // // Note: The data are based on the following conditions: Cooling: : Indoor Temperature.7 C(8 F) DB /. C(7 F) WB; - Outdoor Temperature C( F) DB. Heating and Power input: Indoor Temperature C(8 F) DB/ C( F) WB; - Outdoor Temperature 7 C(. F) DB/ C(.8 F) DB.
12 ClimaCreator Series RA Rooftop Package Unit Hz. Dimensional Drawings..&7.ton Condenser fan 8 Maintain orifice for air supply motor Hole for bottom installation 8-x 7 8
13 ClimaCreator Series RA Rooftop Package Unit Hz. 8.&ton Condenser fan 7 Maintain orifice for air supply motor Hole for bottom installation -x
14 ..&ton ClimaCreator Series RA Rooftop Package Unit Hz Condenser fan 7 Maintain orifice for air supply motor Hole for bottom installation, -x
15 ClimaCreator Series RA Rooftop Package Unit Hz. 7.&on Condenser fan 7 Maintain orifice for air supply motor 7 Compressor panel Horizontal supply open Horizontal return open Control panel
16 ClimaCreator Series RA Rooftop Package Unit Hz. &ton Condenser fan Maintain orifice for air supply motor Drain connection hole Hole for wires Horizontal supply opening Horizontal return opening Hole for bottom installation - 8
17 ClimaCreator Series RA Rooftop Package Unit Hz 7. Wiring Diagrams T application 7. BSRC-HWN-R TO THE WIRE CONTROLLER XT HEAT PUMP ONLY -WAY VALVE CODE COMP FAN FAN CAP CAP XP- XS- RT- KM T T K K L-PRO XT XT XT WIRING DIAGRAM PART NAME COMPRESSOR INDOOR FAN OUTDOOR FAN INDOOR FAN CAP OUTDOOR FAN CAP CONNECTORS CONNECTORS TEMP.SENSOR AC CONTACTOR TRANSFORMER(V~) TRANSFORMER HIGH PRESS SWITCH COMP.TEMP. SWITH LOW PRESS SWITCH -WAY TERMINAL MIDDLE TERMINAL -WAY TERMINAL T XT CN CN CN WHITE L L T V CN L N POWER CN XT CT PURPLE MAIN CONTROL BOARD BLU E B Y G C R CN CN RL CN CN7 CN CN CN YELLOW FAN WHITE GREEN RY COM A CAP WHITE BRO WN NO FAN KM CAP A CN XP XS L-PRO HEAT CN7 CN8 XSXP W U COMP V WHITE CN8 CN XSXP K RT RT RT XP XS K RT HEAT PUMP ONLY
18 ClimaCreator Series RA Rooftop Package Unit Hz 7. BSRC-7HWN-R TO THE WIRE CONTROLLER XT HEAT PUMP ONLY -WAY VALVE CODE COMP FAN FAN CAP CAP XP- XS- RT- KM T T K K L-PRO XT XT XT WIRING DIAGRAM PART NAME COMPRESSOR INDOOR FAN OUTDOOR FAN INDOOR FAN CAP OUTDOOR FAN CAP CONNECTORS CONNECTORS TEMP.SENSOR AC CONTACTOR TRANSFORMER(V~) TRANSFORMER HIGH PRESS SWITCH COMP.TEMP. SWITH LOW PRESS SWITCH -WAY TERMINAL MIDDLE TERMINAL -WAY TERMINAL T XT CN CN CN WHITE L L T V CN L N POWER CN XT CT PURPLE MAIN CONTROL BOARD BLU E B Y G C R CN CN RL CN CN7 CN CN CN YELLOW FAN WHITE GREEN RY COM A CAP WHITE BRO WN NO FAN KM CAP A CN XP XS L-PRO HEAT CN7 CN8 XSXP W U COMP V WHITE CN8 CN XSXP K RT RT RT XP XS K RT HEAT PUMP ONLY
19 CN ClimaCreator Series RA Rooftop Package Unit Hz 7. BSRC-HWN-R TO BE CONNECTED KJR-B CN CN XS XP- XS- RT (WHITE) RT_ CN () RT_ CN RT CN RT_ CN RT_ CN S H-PRO L-PRO K CN S H-PRO L-PRO K NOTE:IF ELECTRICAL SOURCE PROTECTION RELAY IS NOT PRESENT, WIRE A IS CONNECTED TO WIRE B. CN -WAY(B) YE LL OW WHITE GREEN CN7 CN SW MAIN BOARD CN8 A B NOTE -WAY(A) FAN_O-PRO R G Y B ( C) XT CN CN CN CN CN CN TO THE WIRE CONTROLLER T T YELLOW GREEN BRO WN SW MODE KJR-B KJR-B A A BL UE CT GR EY BL ACK T(U) KM T(V) COMP_A A A BLU E T(W) CT KM T(V) T(U) COMP_B T(W) A A B LUE GRE Y BL ACK U V FAN_OUT W KM A A BL UE CT CT V U FAN_IN KM W XT L L L N POWER ELECTRICAL SOURCE PROTECTION REALY WHITE R S T COM NC NO BLU E CODE TITLE COMP_A,COMP_B COMPRESSOR FAN _OU T OUTDOOR FAN FAN_IN I N D O O R F A N KM-KM CONTACTOR T,T CT-CT XT XT RT_,RT_ RT H-PRO L-PRO XS- XP- K,K RT TRANSFORMER C U R R E N T I N D U C T O R -WAY TERMINAL SMALL -WAY TERMINAL PIPE TEMP.SENSOR OF UNIT AB OUTDOOR TEMP.SENSOR HIGH PRESSURE SWITCH LOW PRESSURE SWITCH CONNECTORS CONNECTORS TEMP PROTECTION SWITCH INDOOR ROOM TEMP.SENSOR RTR T_ R T_ INDOOR PIPE TEMP.SENSOR FAN_O-PRO OUTDOOR FAN PROTECTION SWITCH 7
20 CN ClimaCreator Series RA Rooftop Package Unit Hz 7. BSRC-HWN-R TO BE CONNECTED KJR-B CN CN XS XP- XS- RT (WHITE) RT_ CN () RT_ CN RT CN RT_ CN RT_ CN S H-PRO L-PRO K CN S H-PRO L-PRO K NOTE:IF ELECTRICAL SOURCE PROTECTION RELAY IS NOT PRESENT, WIRE A IS CONNECTED TO WIRE B. CN -WAY(B) YEL LOW WHITE GREEN CN7 CN MAIN BOARD CN8 A B NOTE -WAY(A) FAN_O-PRO R G Y B ( C) XT CN CN CN CN CN CN TO THE WIRE CONTROLLER T T YELLOW GREEN SW MODE KJR-B KJR-B A A CT T(V) T(U) KM COMP_A A A T(W) CT KM T(V) T(U) COMP_B T(W) A A U V FAN_OUT W KM A A CT CT V U FAN_IN KM W XT L L L N POWER WHITE R S T COM NC NO CODE TITLE COMP_A,COMP_B COMPRESSOR FAN _OU T OUTDOOR FAN FAN_IN I N D O O R F A N KM-KM T,T CT-CT CONTACTOR TRANSFORMER C U R R E N T I N D U C T O R XT -WAY TERMINAL XT RT_,RT_ SMALL -WAY TERMINAL PIPE TEMP.SENSOR OF UNIT AB RT OUTDOOR TEMP.SENSOR H-PRO HIGH PRESSURE SWITCH L-PRO LOW PRESSURE SWITCH XS- CONNECTORS XP- CONNECTORS K,K TEMP PROTECTION SWITCH RT INDOOR ROOM TEMP.SENSOR RTR T_ R T_ INDOOR PIPE TEMP.SENSOR FAN_O-PRO OUTDOOR FAN PROTECTION SWITCH 8
21 CN ClimaCreator Series RA Rooftop Package Unit Hz 7. BSRC-HWN-R TO BE CONNECTED KJR-B CN CN XS XP- XS- RT (WHITE) RT_ CN () RT_ CN RT CN RT_ CN RT_ CN S H-PRO L-PRO K CN S H-PRO L-PRO K NOTE:IF ELECTRICAL SOURCE PROTECTION RELAY IS NOT PRESENT, WIRE A IS CONNECTED TO WIRE B. CN -WAY(B) YEL LOW WHITE GREEN CN7 CN MAIN BOARD CN8 A B NOTE -WAY(A) FAN_O-PRO R G Y B ( C) XT CN CN CN CN CN CN TO THE WIRE CONTROLLER T T YELLOW GREEN SW MODE KJR-B KJR-B A A CT T(V) T(U) KM COMP_A A A T(W) CT KM T(V) T(U) COMP_B T(W) A A U V FAN_OUT W KM A A CT CT V U FAN_IN KM W XT L L L N POWER WHITE R S T COM NC NO CODE TITLE COMP_A,COMP_B COMPRESSOR FAN _OU T OUTDOOR FAN FAN_IN I N D O O R F A N KM-KM T,T CT-CT CONTACTOR TRANSFORMER C U R R E N T I N D U C T O R XT -WAY TERMINAL XT RT_,RT_ SMALL -WAY TERMINAL PIPE TEMP.SENSOR OF UNIT AB RT OUTDOOR TEMP.SENSOR H-PRO HIGH PRESSURE SWITCH L-PRO LOW PRESSURE SWITCH XS- CONNECTORS XP- CONNECTORS K,K TEMP PROTECTION SWITCH RT INDOOR ROOM TEMP.SENSOR RTR T_ R T_ INDOOR PIPE TEMP.SENSOR FAN_O-PRO OUTDOOR FAN PROTECTION SWITCH
22 CN ClimaCreator Series RA Rooftop Package Unit Hz 7. BSRC-HWN-R TO BE CONNECTED KJR-B XS JP CN CN XP- XS- RT_ RT (W HITE) CN () RT_ CN RT CN RT_ CN RT_ CN BL UE S H-PR O L-PRO K CN S H-PR O L-PRO K CN NOTE:IF ELECTRICAL SOURCE PROTECTION RELAY IS NOT PRESENT, WIRE A IS CONNECTED TO WIRE B. B LUE -WAY(B) Y EL LO W WHITE GREEN CN7 CN SW MAIN BOARD CN8 A B LUE B NOTE FAN_O-PRO -WAY(A) FAN_O-PRO R G Y B ( C) XT CN CN CN CN CN CN TO THE WIRE CONTROLLER T T B ROWN YELLOW GREEN WHITE SW MODE KJR-B KJR-B A A B LU E CT WHITE T(U) T(V) KM COMP_A A A BL UE T(W) CT B LUE WHI TE KM T(V) T(U) COMP_B T(W) A A BLU E G REY BR OWN U V W FAN_OUT KM A A BL UE B LACK B ROWN U V W FAN_OUT KM A A BLU E CT CT B ROWN V U FAN_IN KM W XT BROW N LLL N POWER WHITE R S T COM NC NO BL UE CODE TITLE COMP_A,COMP_B COMPRESSOR FAN _OU T OUTDOOR FAN FAN_IN KM-KM T,T CT-CT XT XT RT_,RT_ RT H-PRO L-PRO XS- XP- K,K RT I N D O O R F A N CONTACTOR TRANSFORMER C U R R E N T I N D U C T O R -WAY TERMINAL SMALL -WAY TERMINAL PIPE TEMP.SENSOR OF UNIT AB OUTDOOR TEMP.SENSOR HIGH PRESSURE SWITCH LOW PRESSURE SWITCH CONNECTORS CONNECTORS TEMP PROTECTION SWITCH INDOOR ROOM TEMP.SENSOR RTR T_ R T_ INDOOR PIPE TEMP.SENSOR FAN_O-PRO OUTDOOR FAN PROTECTION SWITCH Jp NET JUMPER
23 CN ClimaCreator Series RA Rooftop Package Unit Hz 7.7 BSRC-HWN-R X Y E TO BE CONNECTED KJR-B/KJR-B NIM CN NET CONTROL MODULE CN CN XS XP- XS- RT_ RT (W HITE) CN () RT_ CN RT CN RT_ CN RT_ CN BL UE S H-PR O L-PRO K CN S H-PR O L-PRO K NOTE:IF ELECTRICAL SOURCE PROTECTION RELAY IS NOT PRESENT, WIRE A IS CONNECTED TO WIRE B. CN -W AY(B) Y EL LO W WHITE GREEN CN7 CN SW MAIN BOARD CN8 A B NOTE FAN_O-PRO -WAY( A) FAN_O-PRO R G Y B ( C) XT CN CN CN CN CN CN TO THE WIRE CONTROLLER T T B ROWN YELLOW WHITE GREEN SW MODE KJR-B/KJR-B KJR-B A A B LU E CT WHITE T(U) KM T(V) COMP_A A A BL UE T(W) CT B LUE WHI TE T(V) T(U) KM COMP_B T(W) A A BLU E BR OWN U V W FAN_OUT KM A A BL UE B ROWN B LACK U V W FAN_OUT KM A A BLU E CT CT GR EY B LACK B ROWN U V FAN_IN KM W XT BROW N L L L N POWER WHITE R S T COM NC NO B LU E CODE TITLE COMP_A,COMP_B COMPRESSOR FAN _OU T OUTDOOR FAN FAN_IN KM-KM T,T CT-CT XT XT RT_,RT_ RT H-PRO L-PRO XS- XP- K,K RT I N D O O R F A N CONTACTOR TRANSFORMER C U R R E N T I N D U C T O R -WAY TERMINAL SMALL -WAY TERMINAL PIPE TEMP.SENSOR OF UNIT AB OUTDOOR TEMP.SENSOR HIGH PRESSURE SWITCH LOW PRESSURE SWITCH CONNECTORS CONNECTORS TEMP PROTECTION SWITCH INDOOR ROOM TEMP.SENSOR RTR T_ R T_ INDOOR PIPE TEMP.SENSOR FAN_O-PRO OUTDOOR FAN PROTECTION SWITCH
24 CN ClimaCreator Series RA Rooftop Package Unit Hz 7.8 BSRC-HWN-R X Y E TO BE CONNECTED KJR-B/KJR-B NIM CN NET CONTROL MODULE CN CN XS XP- XS- RT_ RT (W HITE) CN () RT_ CN RT CN RT_ CN RT_ CN BL UE S H-PR O L-PRO K CN S H-PR O L-PRO K NOTE:IF ELECTRICAL SOURCE PROTECTION RELAY IS NOT PRESENT, WIRE A IS CONNECTED TO WIRE B. CN -W AY(B) Y EL LO W WHITE GREEN CN7 CN SW MAIN BOARD CN8 A B NOTE FAN_O-PRO -WAY( A) FAN_O-PRO R G Y B ( C) XT CN CN CN CN CN CN TO THE WIRE CONTROLLER T T B ROWN YELLOW WHITE GREEN SW MODE KJR-B/KJR-B KJR-B A A B LU E CT WHITE T(U) KM T(V) COMP_A A A BL UE T(W) CT B LUE WHI TE T(V) T(U) KM COMP_B T(W) A A BLU E BR OWN U V W FAN_OUT KM A A BL UE B ROWN B LACK U V W FAN_OUT KM A A BLU E CT CT GR EY B LACK B ROWN U V FAN_IN KM W XT BROW N L L L N POWER WHITE R S T COM NC NO B LU E CODE TITLE COMP_A,COMP_B COMPRESSOR FAN _OU T OUTDOOR FAN FAN_IN KM-KM T,T CT-CT XT XT RT_,RT_ RT H-PRO L-PRO XS- XP- K,K RT I N D O O R F A N CONTACTOR TRANSFORMER C U R R E N T I N D U C T O R -WAY TERMINAL SMALL -WAY TERMINAL PIPE TEMP.SENSOR OF UNIT AB OUTDOOR TEMP.SENSOR HIGH PRESSURE SWITCH LOW PRESSURE SWITCH CONNECTORS CONNECTORS TEMP PROTECTION SWITCH INDOOR ROOM TEMP.SENSOR RTR T_ R T_ INDOOR PIPE TEMP.SENSOR FAN_O-PRO OUTDOOR FAN PROTECTION SWITCH
25 8. Performance Data T application 8. Cooling capacity for.ton: Ambient Temperature Notes: Air Flow(CFM) 8 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for.ton: Outdoor Temp( F) 7% RH Net Capacities(kW)-8 CFM Peak Net Heating(kW) at Indicated Dry Bulb( F) Peak Total Power (kw) at Indicated Dry Bulb( F) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
26 ClimaCreator Series RA Rooftop Package Unit Hz 8. Cooling capacity for 7.Ton: Ambient Temperature Notes: Air Flow(CFM) 8 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for 7.Ton: Outdoor Temp( ) 7% RH Net Capacities(kW)-8 CFM Peak Net Heating(kW) at Indicated Dry Bulb( ) Peak Total Power(kW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
27 8. Cooling capacity for 8.Ton: Ambient Temperature Notes: ClimaCreator Series RA Rooftop Package Unit Hz Air Flow(CFM) 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for 8.Ton: Outdoor Temp( ) 7% RH Net Capacities(kW)- CFM Peak Net Heating(kW) at Indicated Dry Bulb( ). 8 Peak Total Power(kW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
28 ClimaCreator Series RA Rooftop Package Unit Hz 8. Cooling capacity for Ton: Ambient Temperature Notes: Air Flow(CFM) 8 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: 8Btu/h) SC=Sensible Capacity. (Unit: Btu/h) Heating capacity for Ton: Outdoor Temp( ) 7% RH Net Capacities(kW)- CFM Peak Net Heating(kW) at Indicated Dry Bulb( ) Peak Total Power(KW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region
29 8. Cooling capacity for.ton: Ambient Temperature Notes: ClimaCreator Series RA Rooftop Package Unit Hz Air Flow(CFM) 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h) SC=Sensible Capacity. (Unit: Btu/h) Heating capacity for.ton: Outdoor Temp( ) 7% RH Net Capacities(kW)- CFM Peak Net Heating(kW) at Indicated Dry Bulb( ) Peak Total Power(KW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region. 7
30 ClimaCreator Series RA Rooftop Package Unit Hz 8. Cooling capacity for Ton: Ambient Temperature Notes: Air Flow(CFM) 7 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for Ton: Outdoor Temp( ) 7% RH Net Capacities(kW)-7 CFM Peak Net Heating(kW) at Indicated Dry Bulb( ) 87. Peak Total Power(KW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region. 8
31 8.7 Cooling capacity for 7.Ton: Ambient Temperature Notes: ClimaCreator Series RA Rooftop Package Unit Hz Air Flow(CFM) Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for 7.Ton: Outdoor Temp( ) 7% RH Net Capacities(kW)-7 CFM Peak Net Heating(kW) at Indicated Dry Bulb( ) 7. Peak Total Power(KW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
32 ClimaCreator Series RA Rooftop Package Unit Hz 8.8 Cooling capacity for Ton: Air Flow(CFM) Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI Ambient Temperature 7 TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC Notes: PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for Ton: Net Capacities(kW)-88 CFM Outdoor Temp( ) 7% RH Peak Net Heating(kW) at Indicated Dry Bulb( ) Peak Total Power(KW) at Indicated Dry Bulb( ) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
33 ClimaCreator Series RA Rooftop Package Unit Hz 8. Cooling capacity for Ton: Air Flow(CFM) 8 Ent(DB) ( ) TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC Ambient Temperature 7 SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC Notes: PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for Ton: Outdoor Temp( F) 7% RH Peak Net Heating(kW) at Indicated Dry Bulb( F) Net Capacities(kW)- CFM Peak Total Power (kw) at Indicated Dry Bulb( F) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
34 ClimaCreator Series RA Rooftop Package Unit Hz 8. Cooling capacity for Ton: Air Flow(CFM) Ent(DB) ( ) Ambient Temperature Notes: TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI All capacities are gross and have not considered indoor fan heat. To obtain NET cooling capacity subtract indoor fan heat.. TC=Total Capacity. (Unit: Btu/h).. SC=Sensible Capacity. (Unit: Btu/h). Heating capacity for Ton: Outdoor Temp( F) 7% RH Peak Net Heating(kW) at Indicated Dry Bulb( F) Net Capacities(kW)- CFM Peak Total Power (kw) at Indicated Dry Bulb( F) Notes:. For other airflows, see heating capacity correction factor tables.. Heating capacities and power are integrated to include the effects of defrost in the frost region.
35 ClimaCreator Series RA Rooftop Package Unit Hz. Electrical Data T Application Model Power Supply Compressor Evaporator fan motor Condenser fan motor MCA TOCA MFA STC RNC IPT Qty RNC IPT Qty RNC (each) IPT (each) Qty BSRC-HWN-R BSRC-7HWN-R BSRC-HWN-R BSRC-HWN-R BSRC-HWN-R BSRC-HWN-R BSRC-HWN-R BSRC-HWN-R Voltage imbalance between phases to be <% MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) RNC: Running Current (A) TOCA: Total Over-current Amps. (A) STC: Starting Current (A) IPT: Input (kw)
36 ClimaCreator Series RA Rooftop Package Unit Hz. Fan performance data. Blower drive options Power supply Nominal capacity(ton) HP MOTOR PULLEY PITCH RPM DIA. (INCH) BLOWER SPEED RANGE (RPM) PULLEY PITCH MINIMUM MAXIMUM DIA. (INCH) 8..~ ~ ~ V N~ Hz..~ ~ ~ ~ ~.. Example for selection process: The following data are the rated design points for model 8. ton: Air flow(cfm)=cfm, Extermal static pressure(esp)=7pa Fan speed(rpm)=8, Power input(w)=, The no. of turns (N) = To increase the ESP to Pa, but maintain the airflow rate at CFM, Please follow the steps below: Step : Selection of new desired point. From the table data, select the point that can meet both of the requirements (ESP = Pa and airflow rate(near or equal to) = CFM). Step : Read Fan speed(rpm), Power input(w): Air flow(cfm)=8cfm, Fan speed(rpm)=8, Power input(w)= Step : Read number of turns for variable pitch pulley. Similarly, use this RPM valve to read the no. of turns (N) by referring to the table of Motor Variable Pitch Pulley Data. The variable pitch pulley for motor shall be adjusted to this N in order to achieve the desired point (ESP = Pa and airflow rate =8cfm). For instance, from the table, no. of turns (N) =. in order to get 8CFM. First, adjust the motor pulley to turns. Then, makes. turns on the pulley. Cross check the dimension X, which stands for regulation space of motor pulley. In this case, X =mm.
37 ClimaCreator Series RA Rooftop Package Unit Hz. Model:.Ton Static pressure(pa) High speed Middle speed Low speed 8 Fan speed(rpm) 8 Power input(w) 8 Air flow(cfm) 7 Fan speed(rpm) 7 8 Power input(w) 7 Air flow(cfm) 7 Fan speed(rpm) 8 Power input(w) 8 7 Air flow(cfm) 8 Fan speed(rpm) 7 77 Power input(w) 8 7 Air flow(cfm) 7 Fan speed(rpm) 7 / Power input(w) / Air flow(cfm) / Fan speed(rpm) / Power input(w) 7 8 / Air flow(cfm) 7 / Fan speed(rpm) / / Power input(w) / / Air flow(cfm) 8 / /
38 ClimaCreator Series RA Rooftop Package Unit Hz. Model: 7.Ton Static pressure(pa) High speed Middle speed Low speed 8 Fan speed(rpm) 8 Power input(w) 7 7 Air flow(cfm) 7 7 Fan speed(rpm) 8 Power input(w) Air flow(cfm) 8 8 Fan speed(rpm) Power input(w) 7 Air flow(cfm) 7 Fan speed(rpm) 7 8 Power input(w) 77 Air flow(cfm) 8 8 Fan speed(rpm) 7 / Power input(w) 8 / Air flow(cfm) 7 / Fan speed(rpm) 7 / Power input(w) 8 / Air flow(cfm) 8 87 / Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / /
39 ClimaCreator Series RA Rooftop Package Unit Hz. Model: 8.Ton ESP(Pa) N X..... Fan speed(rpm) Power input(w) Air flow(cfm) 88 Fan speed(rpm) Power input(w) 7 78 Air flow(cfm) Fan speed(rpm) Power input(w) 8 Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) 7 Air flow(cfm) Fan speed(rpm) Power input(w) 7 7 Air flow(cfm) 7 8 Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / 7 Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / / Power input(w) 8 7 / / Air flow(cfm) / / Notes:. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow. 7
40 ClimaCreator Series RA Rooftop Package Unit Hz. Model: Ton ESP(Pa) N X..... Fan speed(rpm) / / / / / / Power input(w) / / / / / / 87 Air flow(cfm) / / / / / / 7 8 Fan speed(rpm) / / / / / Power input(w) / / / / / 8 78 Air flow(cfm) / / / / / 8 8 Fan speed(rpm) / / / / Power input(w) / / / / 8 7 Air flow(cfm) / / / / 7 7 Fan speed(rpm) / / / Power input(w) / / / Air flow(cfm) / / / Fan speed(rpm) / / Power input(w) / / 8 7 Air flow(cfm) / / Fan speed(rpm) / Power input(w) / Air flow(cfm) / Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / / / 7 Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) 7 / / / / Power input(w) 8 7 / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / / / / Power input(w) 7 / / / / / / Air flow(cfm) 8 / / / / / / Fan speed(rpm) 8 / / / / / / Power input(w) / / / / / / Air flow(cfm) 8 / / / / / / Notes:. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow. 8
41 ClimaCreator Series RA Rooftop Package Unit Hz. Model:.Ton ESP(Pa) N X Fan speed(rpm) Power input(w) 8 7 Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / / Power input(w) 8 7 / / Air flow(cfm) / / Fan speed(rpm) / / / / / / 7 Power input(w) / / / / / / Air flow(cfm) 8 7 / / / / / / Notes:. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow.
42 ClimaCreator Series RA Rooftop Package Unit Hz.7 Model: Ton ESP(Pa) N X..... Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / / 8 7 Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / Power input(w) / 8 8 Air flow(cfm) / Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) 8 8 Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) 78 Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) 7 77 Air flow(cfm) Fan speed(rpm) 8 7 / / / / Power input(w) 8 8 / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / / / / / / Power input(w) 7 / / / / / / / / Air flow(cfm) / / / / / / / / Fan speed(rpm) / / / / / / / / Power input(w) 7 / / / / / / / / Air flow(cfm) / / / / / / / / Notes:. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow.
43 ClimaCreator Series RA Rooftop Package Unit Hz.8Model: 7.Ton ESP(Pa) N X Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) 7 7 Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / / / / / Power input(w) 8 / / / / / / Air flow(cfm) 87 7 / / / / / / Fan speed(rpm) / / / / / / / / / / Power input(w) 7 / / / / / / / / / / Air flow(cfm) 8 / / / / / / / / / / Notes:. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow.
44 ClimaCreator Series RA Rooftop Package Unit Hz. Model: Ton ESP (Pa) Notes: N X Fan speed(rpm) / / / / Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / / Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / Power input(w) / / / Air flow(cfm) / / / Fan speed(rpm) / / / Power input(w) / / / Air flow(cfm) / / / Fan speed(rpm) / Power input(w) / Air flow(cfm) / Fan speed(rpm) / Power input(w) / Air flow(cfm) / Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) 8 77 Power input(w) Air flow(cfm) Fan speed(rpm) 7 Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) 7 8 Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / / / / / Power input(w) / / / / / / Air flow(cfm) / / / / / / Fan speed(rpm) 7 8 / / / / / / / / Power input(w) 8 7 / / / / / / / / Air flow(cfm) / / / / / / / / Fan speed(rpm) 8 7 / / / / / / / / / / Power input(w) / / / / / / / / / / Air flow(cfm) 87 / / / / / / / / / / Fan speed(rpm) 8 / / / / / / / / / / / / Power input(w) 7 / / / / / / / / / / / / Air flow(cfm) 7 / / / / / / / / / / / /. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow.
45 . Model: Ton ESP (Pa) Notes: ClimaCreator Series RA Rooftop Package Unit Hz N X Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / / / Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / / / / Power input(w) / / / / / / Air flow(cfm) / / / / / / Fan speed(rpm) 87 7 / / / / / / / / / / Power input(w) 78 7 / / / / / / / / / / Air flow(cfm) 8 / / / / / / / / / / Fan speed(rpm) 88 / / / / / / / / / / / / Power input(w) / / / / / / / / / / / / Air flow(cfm) 7 / / / / / / / / / / / /. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow.
46 ClimaCreator Series RA Rooftop Package Unit Hz. Model: Ton ESP (Pa) Notes: N X Fan speed(rpm) / / / / / / 7 7 Power input(w) / / / / / / Air flow(cfm) / / / / / / 7 Fan speed(rpm) / / / / 7 7 Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / / 8 7 Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) / / / / Power input(w) / / / / Air flow(cfm) / / / / Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) / / Power input(w) / / Air flow(cfm) / / Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) Power input(w) Air flow(cfm) Fan speed(rpm) / / / / / / Power input(w) / / / / / / Air flow(cfm) / / / / / / Fan speed(rpm) / / / / / / Power input(w) / / / / / / Air flow(cfm) / / / / / / Fan speed(rpm) 8 7 / / / / / / Power input(w) 7 7 / / / / / / Air flow(cfm) / / / / / / Fan speed(rpm) / / / / / / Power input(w) / / / / / / Air flow(cfm) / / / / / /. Legend: X: Regulation Space of Motor Pulley (mm);n: Number of Turns; ESP: External Static Pressure (Pa);. PULLEY PITCH Factory set point: The table, no. of turns (N) =.;. Bold data is the performance testing set point;. Shading data are rated airflow.
47 ClimaCreator Series RA Rooftop Package Unit Hz. Refrigerant Cycle Diagram..&7. ton: Cooling only type T Condensor High pressure switch Piston TP Evaporator Comp Low pressure switch T Heat pump type: T High pressure switch Four way valve Condensor Piston TP Evaporator Comp Low pressure switch T TP: Compressor discharge temperature sensor in system T: Indoor coil temperature sensor in system T: Outdoor coil temperature sensor in system
48 ClimaCreator Series RA Rooftop Package Unit Hz. 8.,,.,,7.& ton: Cooling only type: T TP High pressure switch TP High pressure switch Comp Condensor Low pressure switch T T Piston Piston Comp Low pressure switch T Evaporator Heat pump type T High-pressure switch TP Comp A Four-way valve Four-way valve Condersor High-pressure switch TP Low-pressure switch Low-pressure switch Comp B Evaporator T T Piston Piston T. & ton: Cooling only type T TP Comp High pressure switch TP High pressure switch Comp Low pressure switch Condensor Low pressure switch T Capillary T T Capillary Evaporator TP: Compressor discharge temperature sensor in system A and B T: Indoor coil temperature sensor in system A and B T: Outdoor coil temperature sensor in system A and B
49 . Operation Limit. T application ClimaCreator Series RA Rooftop Package Unit Hz Outdoor temperature ( DB) Cooling operating condition Indoor temperature ( WB) Mode Temperature Outdoor temperature Indoor temperature Cooling mode ~ 7 ~ Outdoor temperature ( WB) Heating operating condiction Indoor temperature ( DB) Mode Temperature Outdoor temperature Indoor temperature Heating mode -. ~ ~ Note: Room relative humidity less than 8%. If the unit operates in excess of this figure, the surface of the unit may attract condensation. 7 7
50 ClimaCreator Series RA Rooftop Package Unit Hz. Installation. Lifting Rigging cables should have adequate capability to resist times weight of unit. Before lift, please check and ensure that hooks are holding tightly to unit and lifting angles are no less than. Cloth material or hard-paper should be padded in the contact place between unit and rigging cable. Rigging cable should be entwined a round at the hook for prevent danger by cable slip because of weight unbalance. During lifting, anyone forbidden lingering under the lifting unit. Spreader bars. Service Space. The recommended clearances for single-unit installations are illustrated in following Fig. These minimum requirements are not only an important consideration when determining unit placement, but they are also essential to ensure adequate serviceability, maximum capacity, and peak operating efficiency.. Any reduction of the unit clearances indicated in these illustrations may result in condenser coil starvation or the recirculation of warm condenser air. Actual clearances which appear to be inadequate should be reviewed with a local engineer. Units: mm Overhead air Clearance. Rooftop -- units For roof top applications using a field fabricated frame and ducts, according to the following procedure: ) The frame must be located and secured by bolting or welding to the roof. Flashing is required. ) The hole in the roof must be prepared in advance of installing the unit. ) Secure the ducts to the roof. 8
51 ClimaCreator Series RA Rooftop Package Unit Hz ) Place the unit on the frame or roof curb. ) Secure the unit to the frame or roof curb. ) Insulate any ductwork outside of the structure with at least two () inches of insulation and then weatherproof. There must be a weatherproof seal where the duct enters the structure. 7) Complete the installation according to the instructions. Typical rooftop application with frame:. Ground Level -- Horizontal Units For ground level installations, the unit should be positioned on a pad the size of the unit or larger. The unit must be level on the pad. The pad must not come in contact with the structure. Be sure the outdoor portion of the supply and return air ducts are as short as possible. Installation according to the following procedure: ) Place the unit on the pad. ) Attach the supply and return air ducts to the unit. ) Insulate any ductwork outside of the structure with at least inches of insulation and weatherproof. There must be a weatherproof seal where the duct enters the structure. ) Complete the installation according to the instructions. Typical ground level application:. Installation of condensate drain piping Drain connection hole Drain outlet Snap ring Drain pipe X mm tons Others <X X
52 ClimaCreator Series RA Rooftop Package Unit Hz. Ductwork. Attaching horizontal ductwork to unit ) All conditioned air ductwork should be insulated to minimize heating and cooling duct losses. Use a minimum of two inches of insulation with a vapor barrier. The outside ductwork must be weatherproofed between the unit and the building. ) When attaching ductwork to a horizontal unit, provide a flexible watertight connection to prevent noise transmission from the unit to the ducts. The flexible connection must be indoors and made out of heavy canvas. Note: Do not draw the canvas taut between the solid ducts. Unit Weather proof this seam Field duct.7 Wiring provision Field wiring The units are internally wired at the factory according to generally accepted electrical technology. Required field wiring Main power wiring to the unit control wiring between the control center and the unit, and earth wiring are required in the field. Required components The following components are required: main power fuse, conduit coupling, and field supplied room thermostat. Wire and fuse size selection for main power source. Wire and fuse size should be selected in accordance with national standard, taking the designed maximum current shall be the total of the compressor maximum current, condenser fan motor current and evaporator fan motor current (refer to electrical data ). Wire size between room thermostat and unit. The wire size between the room thermostat and the unit should be determined according to the following table, because the V power source is applied to the control circuit.
53 ClimaCreator Series RA Rooftop Package Unit Hz. Wired Controller. Standard wired controller: KJR-B/DP (T)-E KJR-B/DP (T)-E. SAFETY PRECAUTIONS The following contents are stated on the product and the operation manual, including usage, precautions against personal harm and property loss, and the methods of using the product correctly and safely. After fully understanding the following contents (identifiers and icons), read the text body and observe the following rules. Identifier description
54 . SUMMARIZE Usage condition:. Power supply: V DC.. Operation temperature: Operation humidity: %-%, RH.. FUNCTION SUMMARY Main function:. Connecting to indoor unit by A, B, C, D, E terminal;. Button setting action mode.. LCD display.. Timer for rest time.. NAME AND FUCTION OF INDICATORS ON THE CONTROLLER ClimaCreator Series RA Rooftop Package Unit Hz Operation mode indication: When press " MODE " button, the following mode can be selected in circle. Auto Cool Dry Heat Fan only Auto. For cooling only model,heat mode is skipped. Timer : When adjust setting on time or only on time is set, the "ON" is lighted. When adjust setting off time or only off time is set, the "OFF" is lighted. If both on and off timer are set, both the "ON" and "OFF" are lighted. Follow me function: There is a temperature sensor inside the wire controller, after setting temperature, it will compare the two temperatures, and the space of wire controller will be the same as setting temperature. It is available under cooling, heating, auto mode. ON/OFF indication : When it is on, the icon display, otherwise it is extinguished. Fan speed indication : There are four fan modes : low, middle, high, auto. For some models, no middle fan then the middle fan is seen as high speed. The function is not suitable for the rooftop package units. Lock: When the " LOCK " button is pressed, the icon appear and other buttons is unable, press again, the icon disappear. 7 Temperature display zone: Generally it displays setting temperature, it can be adjusted by press temperature button and. But in fan mode, no display here.
55 ClimaCreator Series RA Rooftop Package Unit Hz. INSTALLATION METHOD When a wired controller is needed, a small -way terminal should be added, fix an infrared emitter with gumwater near the receiver on the switch board. Connect its anode and cathode to A and B, and +V, GND, RUN to C, D, E on the switch board.. NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER Mode button: When press this button, the operation mode change as the following sequence: Remark: For the cooling only model, the heating mode is skipped. Timer on button : Press this button, timer on function is active. Then every press, the time increase.h, after h, h increase after each press. If cancel this Function, just set it to ".". Timer off button: Press this button, timer off function is active. Then every press, the time increase.h, after h, per h increase after each press. If cancel this function, just set it to ".". Follow me button: When under cool, heat and auto mode, press this button, follow me function is active. Press again, this function is ineffective. Electrical heater button : If press this button in heat mode, electrical heater function become ineffective.
56 ClimaCreator Series RA Rooftop Package Unit Hz Reset button(hidden): Use a mm stick to press in the little hole, then the current setting is canceled. The wired controller will enter into original state. 7ON/OFF button: When in off state, press this button, the indicator is on, the wire controller enter into on state, and send setting information to in door PCB. When in on state, press this button, the indicator is off, and send instruction. If timer on or timer off has been set, it cancel this setting then send instruction to stop the machine. 8 Adjust button : Set indoor temperature up. If press and hold on, it will increase at degree per. second. Adjust button : Set indoor temperature down. If press and hold on, it will decrease at degree per. second. Swing button: First pressing: start swing function; second pressing: stop swing. (Match to some model with swing function). Economy operation button: Press this button, the indoor unit operates in economy mode, press it again, exit this mode (it may be ineffective for some models) Fan speed button: Press this button consecutively, the fan speed will circle as follow: Lock button (hidden): When you push the LOCK button, all current settings are locked in and the wire controller does not accept any operation except that of the LOCK button. Use the lock mode when you want to prevent setting from being changed accidentally or play fully. Push the LOCK button again when you want to cancel the LOCK mode. 7. USING METHOD AUTOMATIC OPERATION Connect to power, indoor operation lamp flash.. Press "MODE" button, select " AUTO " ;. Press the button " " and " ", set temperature you want, generally it is among 7 ~ ;. Press " ON/OFF" button, operation lamp is on, the air-conditioner work in auto mode, indoor fan is auto, and can not be changed. Auto is displayed on LCD. Press " ON/OFF" button again to stop.. Economy operation is valid in auto mode. COOL/HEAT/FAN MODE OPERATION. Press "MODE" button, select "COOL", "HEAT" or "FAN ONLY" mode.. Press temperature adjust button to select setting temp... Press "FAN SPEED" button to select high/mid/low/auto.. Press "ON/OFF" button, indoor unit operation lamp on, it works in selected mode. Press "ON/OFF" button again, it stops to work. Remark: When in fan mode, no temperature can be set. DRY OPERATION
57 ClimaCreator Series RA Rooftop Package Unit Hz. Press " MODE " button, select " DRY " mode.. Press temperature adjust button to select setting temp.. Press " ON/OFF " button, indoor unit operation lamp on, it works in dry mode. Press ON/OFF button again, it stops to work.. In dry mode, economy operation and fan speed are ineffective. TIMER SETTING Timer on only:. Press " TIME ON " button, it display "SET" on LCD, and display " H " and "ON", it is waiting for timer on setting.. Press " timer " on button repeatedly to adjust time setting.. If press this button and hold on, the time will increase at.h, after h, it increases at h.. After setting. second, the wire controller send timer on information, it is finished. Timer off only:. Press "TIME OFF " button, it display "SET" on LCD, and display " H " and ON, it is waiting for timer on setting.. Press "TIME OFF" button repeatedly to adjust time setting.. If press this button and hold on, the time will increase at.h, after h, it increases at h.. After setting. second, the wire controller send timer off information, it is finished. TIMER ON AND TIMER OFF BOTH. Set timer on time as the corresponding step and.. Set timer off time as the corresponding step and.. Timer off time must be longer than timer on time... second after setting, the wire controller send information, the setting is finished. CHANGE TIMER If there is a timer of changing time to be need, press corresponding button to revise it. If cancel timer, change time to.. NOTE: The timer time is relative time, that is delay after setting time ( i, e: setting time is 8: A,M). So when timer is set, the standard time can not be adjusted. 8. TECHNICAL INDICATION AND REQUIREMENT EMC and EMI comply with the CE certification requirements.
58 . Optional wired controller: ClimaCreator Series RA Rooftop Package Unit Hz KJR-B: For cooling only and cooling with auxiliary heater KJR-B: For Cooling and heating KJR-B KJR-B. Control wiring To connect wired controller For C/O Units For E/Heater+C Units R G Y (C) R G Y W (C) Power supply L L L N Next wire joint also available L L L N For C/O Units.-7. TONS MAIN CONTROL BOARD B Y G R C GREEN YELLOW C R G Y B XT TOTHE WIRE CONTROLLER
59 ClimaCreator Series RA Rooftop Package Unit Hz Suggestion: Thermostat choose KJR-B or Non-programmed electrical thermostat series of Honeywell, such as THD. Wiring please refer to the Owner s Manual of the thermostat. Dial code setting Set the dial code SW of PCB in unit s wire control box, after settings, please shut off the power supply and then repower, otherwise, the new settings function couldn t work. When select the KJR-B wired controller, please set the SW in ON. When select the wired controller be recommended, please set the SW in. For C/O Units 8.- TONS KJR- B A B C D E -terminal Group BROW N YELLOW BL ACK WH ITE ON SW CN7 MAIN CONTROL BOARD CN CN WHITE YELLOW GREEN R G Y (C) XT TOTHE WIRE CONTROLLER For E/Heater+C Units KJR- B A B C D E -terminal Group BROW N YELLOW BL ACK WH ITE CN ON SW CN7 MAIN CONTROL BOARD CN WHITE YELLOW R G Y W(C) GREEN XT TOTHE WIRE CONTROLLER 7
60 ClimaCreator Series RA Rooftop Package Unit Hz. Error Code. Error Code for.&7.ton NUM 7 CODE LED() LED(YELLOW) LED(GREEN) STANDBY OFF OFF ON FUNCTION ON ON ON PHASE-MISSING PHASE-ERROR FLASH FLASH FLASH T SENSOR FAILURE HIGH PRESSURE PROTECTION VENT PROTECTION T SENSOR FAILURE FLASH FLASH FLASH OFF FLASH FLASH T SENSOR FAILURE T SENSOR FAILURE OFF FLASH FLASH ON FLASH FLASH 8 T EVAPORATOR LOW TEMP. PROTECTION T EVAPORATOR HIGH TEMP. PROTECTION T CONDENSOR HIGH TEMP. PROTECTION LINE CONTROLLER INPUT FAILURE OFF FLASH FLASH FLASH FLASH ON OFF FLASH OFF ON OFF ON COMPRESSOR OVERCURRENT PROTECTION OFF OFF FLASH COMPRESSOR-INHALING LOW PRESSURE PROTECTION FLASH ON FLASH DEFROST ON FLASH FLASH 8
61 ClimaCreator Series RA Rooftop Package Unit Hz Error code for8.ton and above
tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application
6.2-30 tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application High-performance, energy-saving, cost-effective rooftop air conditioning solutions for your business
More information60Hz R410A ClimaMaster Tropical Rooftop Package Unit. Content. 1. Models List External Appearance Nomenclature...
0Hz R40A ClimaMaster Tropical Rooftop Package Unit MCAC-RTSM-20-0 Content. Models List... 2. External Appearance.... Nomenclature... 2 4. Feature & Benefit.... List of Function.... Specification... 8 7.
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More information1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A
Contents 1. Product Lineup... 1 2. External Appearance... 1 3. Nomenclature... 1 4. Features... 2 5. List of Functions... 3 6. Specifications... 6 7. Dimensional Drawings... 8 8. Wiring Diagrams... 9 9.
More informationClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n
1311-R1211 GD Midea Refrigeration Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 D e a l e r i n f o r m a t i o n GD Midea Refrigeration
More informationINSTALLATION & OWNER S MANUAL
ROOFTOP PACKAGE COOLING ONLY 7.5, 0, 5, 20 y 25 Tons. IPCH090KF-5, IPCH20KF-5, IPCH80KF-5, IPCH240KF-5, IPCH300KF-5. INSTALLATION & OWNER S MANUAL intensity.mx MAN-I-IPCH/5-098 CONTENTS Thank you very
More informationINSTALLATION & OWNER S MANUAL
INSTALLATION & OWNER S MANUAL Rooftop Package Type R410A PEK SERIES Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep
More informationCommercial Air Conditioners Rooftop Package. R410A 50Hz
Commercial Air Conditioners 2016 Rooftop Package R410A 50Hz Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and
More informationCOMMERCIAL AIR CONDITIONERS
MCAC09 COMMERCIAL AIR CDITIERS R Tropical Rooftop Package Unit 0Hz ton 0 Coercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea coercial air conditioner
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationROOFTOP PACKAGE (GC201105) TECHNICAL SALES GUIDE-50&60Hz CAPACITY RANGE:3~30TON SUPER HIGH AMBIENT OPERATION TO 55
ROOFTOP PACKAGE (GC201105) ER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDIT TECHNICAL SALES GUIDE-50&60Hz CAPACITY RANGE:3~30TON SUPER HIGH AMBIENT
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More information50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant
Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationSplit System Heat Pumps
Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationProduct Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons
Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units
More informationR22 air-cooled modular chiller 50Hz unit. Content
Content 1.Nomenclature... 2 2.Product Schedule... 2. External Appearance... 4.Features... 4 5.Specification... 6 6.Dimension... 10 7.Refrigeration System Sketch Drawing... 14 8.Wiring Diagrams... 16 9.Electric
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationSELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS
SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationUnit Features & Benefits RQPM/RQRM Series
2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable
More information50TJM 60Hz Nominal Cooling Capacity Tons HFC R - 410A Refrigerant
Package Rooftop Units 60Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation:
More informationDC Inverter Multi-split System Technical Manual - 50Hz/R410a
DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/1.0/201111 Content Contents Part 1. General Information... 1 1. Features... 1 2. Nomenclature... 3 3. Products Line-up... 5 4.
More informationEngineering Data Book
40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationUP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationRuud Commercial Achiever Series Package Gas Electric Unit
Package Gas Electric Ruud Commercial Achiever Series Package Gas Electric Unit RKPN- 14 SEER Series RKQN- 15 SEER Series Nominal Sizes 3-5 Tons [10.6-17.6 kw] (15 SEER/12.0 EER AND ABOVE ONLY) Proper sizing
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More informationSplit System Cooling Units
Split System Cooling Units Split System Cooling Units 7.5 to 20 Tons Air Handlers 7.5 to 20 Tons 50 Hz June 2006 Introduction Split System Cooling Units... Designed With Your Needs In Mind. The Trane reputation
More informationProduct Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C
Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and
More informationtechnical guide Water-Cooled Self-Contained Units
technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................
More informationEngineering Data Book
40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationCeiling & Floor type Unit
Ceiling & Floor type Unit Part 1. Product Features Quietest operation, low noise. Thin design, space-saving. Easy to operate, remote control. 16 Part 2. Specification Model MUA-18HRN2 MUA-24HRN2 MUA-24HRN2
More informationProduct Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56
38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationProduct Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons
(60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result
More informationEngineering Data Book
40VMU Under Ceiling/Floor Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationVERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons
491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationCoolSpot Engineering Guide
Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product
More informationCATALOG. SKYPAK Self-Contained Heating/Cooling Units
CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK
More informationHighly Efficient,Powerful Heating and Cooling.
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2
More informationEngineering Data Book
40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationUCV CONDENSING UNITS SPECIFICATIONS 1. Specifications
UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated
More informationRooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More information[U] Serie MOV. Manual de Ingeniería
[U] Serie MOV Uniidades Condensadoras (Fllujjo Verttiicall) 6..3,, 8 y 12..5 Ton Manual de Ingeniería - 112- Outdoor Units_MOV 1. Specifications.... 2. Dimension... 3. Service Space. 4. Piping Diagrams
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationEngineering Data Book
40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationWater-Cooled Self-Contained Units
CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationProduct Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons
Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece
More informationHigh static Pressure Duct Type Air-conditioner
High static Pressure Duct Type Air-conditioner Part 1. Product Features In case the ceiling is super-high. Blowing pressure of Indoor Unit can reach 196Pa. The air conditioner delivers cold wind to every
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationDC Inverter Multi-split System Technical Manual - 50Hz/R410a
DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/2.0 General Information Contents Part 1. General Information... 4 1. Features... 4 2. Nomenclature... 6 3. Products Line-up...
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationDUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C
DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationEER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER
ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationEngineering Data Manual
Engineering Data Manual Residential Split Low Silhuoette LSN DCI Inverter Series Indoor Units LSN 25 DCI LSN 35 DCI LSN 50 DCI LSN 60 DCI LSN 72 DCI Outdoor Units ONG 25 DCI ONG 35 DCI ONG 50 DCI GC 60
More informationProduct Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons
Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits
More informationAIR-CONDITIONER SERVICE MANUAL
FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED
More informationContents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79
MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary
More informationDSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data
DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal
More informationProduct Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017
Product Catalog Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz June 2017 RT-PRC079B-EN Introduction Packaged Rooftop Air Conditioners Copyright Through the years, Trane
More informationPAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationNominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)
ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999
More informationASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh
PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically
More information