1 BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP
2 1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling, with advanced DC inverter technology, saving 40% electricity than normal on/off heat pump in practical operation. It offers the users with maximum comfort the whole year through. It can work with solar, boiler or electric heater according to practical condition of the heating system. Features Inverter technology ensures super efficient performance and low energy consumption 5 modes: heating only, heating+hot water, hot water only, cooling only, cooling+hot water. With control output for 3 way valve With Intelligent temperature compensation function, the water setting temperature adjusts automatically as the house s heat loss changes Automatically variable fan speed in 3 grades to optimize heating efficiency Can work with room thermostat Can work with auxiliary heater Low ambient design, the units can work at low ambient conditions up to -20
3 Enjoy comfortable life with 2 SUPER PERFORMANCE THANKS TO THE INVERTER TECHNOLOGY The high COP (coefficient of performance) of the unit is largely attributed to Buleway s inverter technology. An integrated frequency-converter adjusts the rotational speed of the compressor to suit the heating demand. Therefore, the system seldom operates at full capacity and the customer only pays for the energy which they actually need. BLUEWAY INVERTER AIR-to-WATER HEAT PUMPS BENEFITS BOTH NEW CONSTRUCTION AND RETROFIT INSTALLATIONS
4 3 Enjoy comfortable life with DC INVERTER Split type heat pump BLUEWAY Split Type Inverter Air to Water Heat Pump has an outdoor unit and an indoor unit. The compressor is located in the outdoor unit and the hydronic components are located in the indoor unit. The outdoor unit and indoor unit are connected with refrigerant piping. The compact outdoor unit extracts heat from the outside ambient air and transfers it inside through refrigerant piping to supply heating. Free Standing Indoor Unit Wall Mounted Indoor Unit Outdoor Unit FEATURES Split design with water system indoor, preventing water frozen problem Aviation plug for wire connection between indoor unit and outdoor unit, simplifies installation and avoids mistakes Allows absence of buffer tank With water pressure gauge in indoor unit
5 Enjoy comfortable life with 4 APPLICATIONS Heating+ Cooling+ Domestic Hot Water Heating using under floor heating loops, Low temperature radiators and fan coil units. Cooling using only fan coil units. Hot water for domestic use is delivered by the domestic hot water tank connected to the indoor unit. APPLICATION R-410A REFRIGERANT PIPING Between outdoor unit and indoor unit H2O PIPING INSTALLER'S ADVANTAGES Between indoor unit and indoor heating terminals ( under floor heater, radiator, domestic hot water tank, fan coil unit) No extra insulation of H2O piping required to protect from freezing up Refrigerant out Refrigerant in Water in Water out Water in Demestic hot water Water out Radiators Fan Coil Under-floor heating
6 5 Enjoy comfortable life with KEY COMPONENTS INDOOR UNIT STANDARD UNIT COMPOSITION SUS 316 OF BRAZED PLATE HEAT EXCHANGER MOTORIZED 3-WAY VALVE (OPTIONAL) CIRCULATION WATER PUMP EXPANSION VESSEL BUFFER TANK WITH ELECTRIC BACK UP HEATER ELEMENT SAFETY VALVE AIR PURGE VALVE FULL SEALED CONTROL BOX WITH WATER PROOF LEVEL IPX5 INTELLIGENT USER INTERFACE WATER PRESSURE GUAGE RERIGERANT PRESSURE GUAGE FLOW SWITCH FOR WATER FLOW PROTECTION BASE FRAME AND EXTERNAL FRAME MADE OF POWDER COADTED STEEL 1 Refrigerant gas connection(3/4) 2 Refrigerant liquid connection(1/2) 3 Air conditioner water outlet(g1) 4 Air conditioner water return(g1) 5 Sanitary hot water outlet(g1) 6 Sanitary hot water return(g1) 7 Y style water filter 8 Non return valve 9 Control panel 10 Electronic 3 way valve 11 Pressure gauge(refrigerant) 12 Water pump 13 Expansion tank 14 Flow switch 15 Electric compartment 16 Pressure relief valve 17 Air purge valve 18 Buffer Tank with back-up heating elements 19 Plate Heat Exchanger OUTDOOR UNIT STANDARD UNIT COMPOSITION INVERTER ROTARY OR SCROLL COMPRESSOR WITH CRANKCASE HEATER AND THERMAL PROTECTION ECO-FRIENDLY HIGH EFFICIENCY R410A REFRIGERANT AIR HEAT EXCHANGER MADE OF INNER GROOVED COPPER TUBES AND BLUE HYDRAULIC COATED ALLUMINUM FINS, FOR HIGH EFFICENCY AND CORROSION RESISTANCE FACTORY WIRED AMBIENT AIR TEMPERATURE SENSOR HEAVY GUAGE GALVANIZED STEEL CABIENT WITH EPOXY POWDER PAINTING FOR LONG LASTING OUTDOOR LIFE SPAN ELECTRIC EXPANSION VALVE AIR PURGE VALVE AUTOMATIC INTELLIGENT DEFROSTING BOTTOM PLATE HEATER TO KEEP THE BASE FREE OF ICE AND THE DRAIN HOLES OPEN HIGH PRESSURE AND LOW PRESSURE PRETECTION
7 Enjoy comfortable life with 6 SPECIFICATION DATAS Model Split DC Inverter Air To Water Heat Pump DHP-09S DHP-12S DHP-15S DHP-15ST DHP-18ST DHP-24ST DHP-30ST HP Power supply V/Ph/Hz V/1Ph/50Hz V/3Ph/50Hz Heating capacity kw / 35 floor heating Power input kw COP Heating capacity kw / 35 floor heating Power input kw COP Cooling capacity kw / 35 floor heating Power input kw EER Heating capacity kw / 45 radiators Power input kw COP Heating capacity kw / 45 radiators Power input kw COP Cooling capacity kw / 7 fan coil Power input kw EER Noise level DB(A) Rated outlet water temp. Max outlet water temp. Ambient temperature range 7~ ~43 Rated water flow rate L/S Rated pressure drop kpa Refrigerant Bar Max. Working Pressure Water Bar Water connection inch 1" 1" 1" 1" 1" 1-1/4" 1-1/4" Controller - Micro processor based digital wire controller with LCD display External cabinet - Galvanized steel with powder coating Make - Mitsubishi Hitachi Type - Rotary Scroll Compressor Nos Refrigerant Refrigerant amount Kg R410A Water heat exchanger Type - Brazed plate heat exchanger Materials - SUS 316 Copper pipe Diameter Gas/Liquid inch 5/8"/1/4" 5/8"/3/8" 3/4"/3/8" 7/8"/1/2" Built in electric heater KW optional optional optional optional optional optional optional Built in 3-way valve - yes yes yes yes yes yes yes Built in pump - Wilo/Xinhu Indoor Unit mm 660*650* *650* *650* *650* *650* *650* x650x1250 (Free Standing Type) Dimension Indoor Unit (W*D*H) mm 508*406* *406* *406* *406* *406* *406* *406*1000 (Wall Mounted Type) Outdoor Unit mm 880*360* *310* *310* *390* *390* x515x x515x1500 Note: 1.The values of heating(cooling) capacity/power input/cop(eer) are based on measurement of EN14511 standard.usage environment,such as operation of the heating equipment,room temperature,and controller adjustments, may cause disparities between practically determined and these values. 2.Sound pressure level measured at distance of 1m from the device. 3.For Free standing type, the compressor is located in the indoor unit; While for Wall Mounted Type, the compressor is located in the outdoor unit.
8 7 Enjoy comfortable life with DC INVERTER Monobloc type heat pump BLUEWAY Monobloc Type Inverter Air to Water Heat Pump adopts inverter technology, supplying heating, cooling and hot water. FEATURES Compact, weather-resistant and easy to install Built in water pump Bottom heater included Built in electric heating element APPLICATIONS NOTE: 1, Heat Pump 2, Storage Tank 3, Water Collector 4, Water Separator 5, Floor Heating 6, Vertical Fan Coil 7, High Wall Fan Coil 8, Sanitary hot water 8
9 Enjoy comfortable life with 8 SPECIFICATION DATAS Monobloc DC Inverter Air To Water Heat Pump Model DHP-09M DHP-12M DHP-15M DHP-15MT DHP-18MT DHP-24MT DHP-30MT HP Power supply V/Ph/Hz V/1Ph/50Hz V/3Ph/50Hz Heating capacity kw / 35 floor heating Power input kw COP Heating capacity kw / 35 floor heating Power input kw COP Cooling capacity kw / 35 floor heating Power input kw EER Heating capacity kw / 45 radiators Power input kw COP Heating capacity kw / 45 radiators Power input kw COP Cooling capacity kw / 7 fan coil Power input kw EER Noise level DB(A) Rated outlet water temp. Max outlet water temp. Ambient temperature range 7~ ~43 Rated water flow rate L/S Rated pressure drop kpa Max. Working Pressure Refrigerant Bar Water Bar Water connection inch 1" 1" 1" 1" 1" 1-1/4" 1-1/4" Controller - Micro processor based digital wire controller with LCD display External cabinet - Galvanized steel with powder coating Make - Mitsubishi Hitachi Type - Rotary Scroll Compressor Nos Refrigerant R410A Refrigerant amount Kg Water heat exchanger Type - Brazed plate heat exchanger Materials - SUS 316 Built in electric heater KW optional optional optional optional optional optional optional Built in 3-way valve - yes yes yes yes yes yes yes Built in pump - Wilo/Xinhu Outdoor Unit mm 1105*470* *470* *470* *470* *470* x515x x515x The values of heating(cooling) capacity/power input/cop(eer) are based on measurement of EN14511 standard.usage environment,such as operation of the heating equipment,room temperature,and controller adjustments, may cause disparities between practically determined and these values. 2.Sound pressure level measured at distance of 1m from the device.
10 FOSHAN BLUEWAY ELECTRIC APPLIANCES CO.,LTD. ADD: 2-9# Zhanye Rd,Honggang Industrial Area,Shunde District,Foshan Guangdong Tel: / Fax: info@heatpumpworld.com Website:
Integrated Heat Pump Water Heater
Integrated Heat Pump Water Heater Applicable for both Kitchen and Bathroom Application Eco-Friendly Renewable Energy Solution to: Sanitary Hot Water ENERGY FROM THE NATURE Blueway Integrated Heat Pump
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More information2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating
2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial
More informationAdvance Split
Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.
More informationThe Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!
www.withairmall.com The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future! Withair offers a wide range of clean energy products and solutions to meet the needs of
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationAQUAHEAT ADVANCE SPLIT
AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw
PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor
More informationS-Therm Air to Water Heat Pumps
S-Therm Air to Water Heat Pumps AIR TO WATER HEAT PUMP Air to water heat pump Nowadays, people are increasingly focusing on the cost of heating as well as on environmental issues. Traditional heating systems
More informationHERO SERIES-DC INVERTER HEAT PUMPS
HERO SERIES-DC INVERTER HEAT PUMPS PHNIX DC inverter heat pump can work efficiently with floor heating, water fan coils or radiators for heatingcooling. WATER FAN COILS DC INVERTER HEAT PUMP FLOOR HEATING
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationHeat Pumps COMFORT NEED IT. When You
Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationLZA High efficiency air to water heat pumps with HP compressor
High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationPAC BT LOW TEMPERATURE HEAT PUMP
PAC BT LOW TEMPERATURE HEAT PUMP Just feel well COP up to. EER up to. PAC BT -7 kw A ++ + PRODUCTS Cooling and heating mode. Monobloc system. Available in 3PH (sizes 1 to 1). High flexibily due to DC Inverter
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationNeosys Product catalogue
00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationDo you want a versatile solution
Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationDES IGN I T ALI A N O
DES IGN I T ALI A N O 01-04-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.
product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationNATURAL HEATING MACHINE
www.lgeaircon.com LG Electronics Air Conditioning & Energy Solution 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 55 Seoul 150-721, Korea Phone: 82-2-777-761 http://www.lgeaircon.com For continual product
More informationSOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!
SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution! Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More informationProduct Line Introduction. Karl Zhang Technical support engineer
Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationEASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB
R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationAIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round
AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features
Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The
More information30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump
PRODUCT SELECTION DATA Monobloc inverter Compact, reliable and efficient More than a Heat Pump Reversible Air to Water Heat Pump 0AW CARRIER participates in the ECP programme for LCP/HP Check ongoing validity
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationDESIGN ITALIANO
DESIGN ITALIANO 01-06-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative
More informationCatalogue 2015 AMITIME ELECTRIC CO., LTD Add: Yandong 5th Rd, Dayan Industrial Zone, Huangpu Town, Zhongshan City, Guangdong, China Tel: 86-760-23973810 Fax: 86-760-23973813 Email: info@amitime.com Http://www.amitime.com
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationHeating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1
Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EBLQ-BB6W Monobloc with bottom plate heater EBLQ-BB6W TABLE OF CONTENTS EBLQ-BB6W Features.............................................................
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationAir cooled industrial chillers
Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationMiraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.
MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC
More informationAir to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model
Air to Water INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE & MONOBLOCK TYPE Compact model is an Economical and Clean hot water heating system by Heat Pump ROOM HEATING HOT WATER is an efficient hot
More informationMPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS
Air chillers and heat pumps MPI DC Outdoor monobloc unit with BLDC compressor MPI DC - 9 kw Large operating range and energy efficiency under every condition BLDC scroll compressor PLUS BLDC rotary compressor
More informationSubmittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationTHE HEAT PUMP CHOICE OF PROFESSIONALS
THE HEAT PUMP CHOICE OF PROFESSIONALS T H E E N E R G Y E F F I C I E N T H E AT I N G S Y S T E M TIME FOR ENERGY EFFICIENT AND INNOVATIVE SOLUTIONS Expectations of consumers are changing. With the high
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationPAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED
PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised
More informationMulti-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw
Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic
More informationAir Cooled Scroll Chiller
Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water
More information30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw
Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationGeolo THE GROUND SOURCE HEAT PUMP PLUSES
Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar
More informationBlue Box Epsilon Echos +
Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating
More information30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw
AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of
More informationSubmittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationHYDRONIC RESIDENTIAL
HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller
More informationSWIMMING POOL HEAT PUMPS
WHAT IS A POOL HEAT PUMP? Swimming pool heat pumps extract the heat stored in the ambient air and transfer it to water. It increases the water temperature to reach the desired level. Comparatively, it
More information30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation
AIR-TO-WATER HEAT PUMPS 30RQV 017-021 NEW Nominal cooling capacity 15-18 kw Nominal heating capacity 17-21 kw greenspeed Easy and fast installation Hydronic module available Inverter technology compressor
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationSubmittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More informationAir-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186
HEATING The careful process of selecting system requirements and design is expanding in Italy. Thanks to continuous technological research for this purpose, an exclusive hydronic pump range has found its
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationYORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS
YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS Efficiency-optimized Heating and Cooling for Best-in-class Performance EC Fans Brazed Plate Heat Exchanger Condenser Coils Optiview
More informationSubmittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System
Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote
More informationERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)
ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors
More informationProducts catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES
Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 1 2 3 Once again, the Energy Panel team has put all their excitement and enthusiasm to create this new publication. We want to make
More informationWZH Ground source heat pumps
Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed
More informationHeat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications
Heat Pump Technology Air Source, Water Source and Ground Source Optimised heat pumps for residential and commercial applications ICS Cool Energy Limited has nearly 25 years experience in supplying and
More informationSubmittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationHeating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3
Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EDHQ-BB6V3 Monobloc without bottom plate heater EDHQ-BB6V3 TABLE OF CONTENTS EDHQ-BB6V3 Features.............................................................
More informationRefrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as
More informationAir to water Heat Pump System
Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a
More informationAIR SOURCE HEAT PUMPS DUAL CLIMA
AIR SOURCE HEAT PUMPS DUAL CLIMA COMPACT MONOBLOC HEAT PUMP COMPLETE INSTALLATION SOLUTION PACK (HEATING, COOLING AND DHW) FULLY RATED HEATING CAPACITY GUARANTEED TO -20ºC CAN BE COMBINED WITH OTHER ENERGIES
More informationOLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER
SHERP ir-water heat pump COP > 4 DHW 60 C Energy class ErP (1) : RENEWLE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity
More informationSlim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump
0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationKälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10
Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationPower Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.
Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationDESIGN & TECHNICAL MANUAL
DTW_1SP005E_01 DESIGN & TECHNICAL MANUAL Comfort series ( Single phase type ) INNOVATIVE SOLUTION OF DOMESTIC HEATING Air to Water Split type 111OUTDOOR UNIT CONTENTS SINGLE PHASE TYPE : WO A060LFCA, WO
More informationKälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98
Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»
More informationSplit Type System. Air to Water Heat Pump
Split Type System Air to Water Heat Pump EXPERTISE AND INNOVATION Daikin Altherma offers complete flexibility for new construction and deep energy refurbishment projects. Using a low temperature hydronic
More information