1 TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245SCH2O( I ) Cooling only model ARGO 235HPH2O( I ) Heat pump model / 2007

2 Table of contents Page A SPECIFICATIONS 1) Unit specifications 1 3 2) Unit specifications 2 4 3) Major Component specifications 5 / 6 B OPERATING RANGE 6 C DIMENSIONAL DATA 7 D PERFORMANCE CHARTS SC and HP1 8 E PERFORMANCE CHARTS SC and HP2 9 F PERFORMANCE CHARTS heat pump1 10 G PERFORMANCE CHARTS heat pump2 11 H WATER SIDE PRESSURE DROP 12 I REFRIGERANT FLOW DIAGRAMS 13 L FUNCTIONS 1) Cool Mode Operation 14 2) Heat Mode Operation 15 3) Auto (Cool/Heat) Mode Operation 16 4) Dry Mode Operation 17 5) Fan Mode Operation 17 6) Auto Fan Speed 17 7) Forcede mode 18 8) Protection Operations in Cool and Dry Modes 18 9) Protection Operations in Operation Heat Mode 19 10) I Feel Function 21 11) Night Function 21 12) Diagnostic 22 13) Jumpers 23 14) Contacts for building automation 27 15) Maintenance 24 16) Manual Unit control and Led indicators 25 17) Ws Imput Switch 26 M ELECTRIC WIRING DIAGRAMS 27/28 N TROUBLESHOOTING 29 O REFRIGERANT CHARGE 36 P CHECKING ELECTRICAL COMPONENTS 37 1) Measurement of Insulation Resistance 37 2) Checking Continuity of Fuse on PCS Ass'y 38 3) Checking Motor Capacitor 38 Q BOILER CONNECTION KIT 39 1) Specifications and operating limits 39 2) Performance charts 40 3) Component specifications 41 4) Hydraulic connections and valves 2 42

3 A SPECIFICATIONS 1) UNIT SPECIFICATIONS 1 UNIT MODEL NOTE Rating conditions cooling : City water : ambient temp. 27 C d.b. / 19 C w.b.- inlet water temp.18 C - outlet 36 C. Water loop : ambient temp. 27 C d.b. / 19 C w.b. - inlet water temp. 30 C - outlet 35 C Hot-water system : ambient temp. 20 C - inlet water temp. 70 C - outlet 60 C. ARGO 245SCH2O Power source V 50 Hz PERFORMANCES IN CITY WATER IN WATER LOOP COOLING COOLING Capacity (air BTU / h conditioner) kw 2,83 2,7 Capacity (hot-water system) BTU / h kw ,1 Air circulation (high/med/low) m 3 / h Water flow m 3 / h 0,165 0,575 Pressure drop kpa 2,0 32,0 Moisture removal (high speed) Cooling l / h 1,2 Dry 27 C ( 60% R.U.) liters / 24h 30 Dry 30 C (80% R.U.) liters / 24h 59 ELECTRICAL RATINGS Voltage rating V Available voltage range V Running Ampere (air conditioner) A 2,9 3,0 Running Ampere (hot-water system) A 0,10 Power input (air conditioner) W Power input (hot-water system) W 27 Power factor 0,96 0,94 E.E.R. / C.O.P 4,42 4,15 Compressor locked rotor amperes A 17 FEATURES Controls / temperature control Microprocessor / I.C. Thermostat Control unit Wireless remote control unit Timer ON / OFF 24 hours and program Fan speed (air conditioner) 3 + Auto Fan speed (hot-water system) 3 Airflow direction Horizontal Auto (manual for hot water system) (Indoor) Vertical Manual Air filter Washable, easy access Compressor Rotary (hermetic) Refrig./Stand. Charge at shipment R410A 360g Refrigerant control Capillary tube Sound pressure Air conditioner Hi/Me/Lo db-a level Hot-water system Hi/Me/Lo db-a Water connections diameter 1/2 " Gas DIMENSIONS AND WEIGHT Height Widht Depht Net weight mm mm mm kg Data can be changed without notice 3

4 2) UNIT SPECIFICATIONS UNIT MODEL Power source PERFORMANCES Capacity (air conditioner) Capacity (hotwater system) V 50 Hz IN CITY WATER IN WATER LOOP COOLING HEATING COOLING HEATING BTU / h kw 2,95 3,15 3,00 3,56 BTU / h kw ,1 m 3 / h m 3 / h 0,165 0,575 Air circulation (high/med/low) Water flow Pressure drop kpa 2,0 40,0 Moisture removal (high speed Cooling l / h 1, , Dry 27 C ( 60% R.U.) liters / 24h Dry 30 C (80% R.U.) liters / 24h ELECTRICAL RATINGS Voltage rating V Available voltage range V Running Ampere (air conditioner) A 2,9 3,8 3,11 3,9 Running Ampere (hot-water system) A 0,10 Power input (air conditioner) W Power input (hot-water system) W 27 Power factor 0,94 0,95 0,95 0,96 E.E.R. / C.O.P 4,68 3,8 4,41 4,14 Compressor locked rotor amperes A 17 FEATURES Controls / temperature control Microprocessor / I.C. Thermostat Control unit Wireless remote control unit Timer ON / OFF 24 hours and program Fan speed (air conditioner) Fan speed (hot-water system) Airflow Horizontal direction Vertical Air filter Compressor Refrig./Stand. Charge at shipment R410A Refrigerant control Sound Air conditioner Hi/Me/Lo db-a pressure level Hot-water system Hi/Me/Lo db-a Water connections diameter DIMENSIONS AND WEIGHT Height Widht Depht Net weight mm mm mm kg NOTE Rating conditions cooling / heating : City water cooling : ambient temp. 27 C d.b. / 19 C w.b.- inlet water temp.18 C - outlet 36 C. City water heating : ambient temp. 20 C d.b. - inlet water temp.18 C - outlet 6 C. Water loop cooling : ambient temp. 27 C d.b. / 19 C w.b. - inlet water temp. 30 C - outlet 35 C Water loop heating : ambient temp. 20 C d.b. - water temp. 15 C Hot-water system : ambient temp. 20 C - inlet water temp. 70 C - outlet 60 C. ARGO 235HPH2O 3 + Auto 3 Auto (manual for hot water system) Manual Washable, easy access Rotary (hermetic) 470g Capillary tube /2 " Gas Data can be changed without notice 3

5 3) MAJOR COMPONENT SPECIFICATIONS UNIT MODEL ARGO 245SCH2O ARGO 235HPH2O CONTROLLER (PCB) Part No. Controls Control circuit fuse (F1) Jumper Setting J1.J5 (see Electric waring diagram) SWITCH INDICATOR ASSY Model Led color REMOTE CONTROL UNIT THERMISTOR (COIL SENSOR) TH1 Resistance (at 25 C) kω THERMISTOR (ROOM SENSOR) TH2 Resistance (at 25 C) kω FAN & FAN MOTOR (FMI) Model Number / Diameter / Lenght mm No. of pole / rpm (230 V, high) Nominal input W Coil resistance (at 25 C) Ω Safety device Open Setting Close Run capacitor (C2) COMPRESSOR (CM) Model Nominal cooling capacity Compressor oil RB68A or Freol Alpha68M Coil resistance (at 20 C) Run capacitor (C1) Overload relay (OLR) Operating Open temperature Close Operating amp. (Ambient temp. 25 C) C µf VAC W cc Ω Ω µf VAC C C SAC ON-OFF IDU Microprocessor 250VAC - 5A -T 2,54mm - 3 pcs 2,54mm - 2 pcs PCB TMR : blu - STB : yellow - OPR : green RC-7 (ST) RC-7 (RC) NTC (with brass pipe) 10 ± 3% 10 ± 5% K35406-MO2024 Cross-flow 1 / Ø100 / / GRY-WHT: WHT-VLT: VLT-ORG: GRY-BRN: (Internal bimetallic type) 150 ± 10K Autoreset 1,5 440 Rotary ( Hermetic) 5PS102EAA C-R : C-S : External 148 ± 5 C 69 ± 9 C Trip in 6 to 16 sec. at 16A 4

6 UNIT MODEL ARGO 245SCH2O ARGO 235HPH2O FLAP MOTOR (FLP) Model Rating Coil resistence (Ambient temp. 25 C) Ω 4 WAYS VALVE (20S) Model Coil rating Coil resistence (Ambient temp. 20 C) Ω HEAT EXCHANGER COIL Coil Rows Fin pitch mm Face area m 2 PLATE EXCHANGER Model Plate N Gas connections Øi mm Water connections Øi mm SOLENOID VALVE Model Coil resistance (at 20 C) Ω Rating C Nominal input FLOW SWITCH Model Water flow rate( ON ) l / min Water flow rate( OFF ) Reed switch features : HIGH PRESSURE SWITCH OPERATING PRESSURE SETTING Contact rating l / min V W bar MP24GA1 DC 12V WHT-BLU (respectively 4 wires) : 380 ± 7% Aluminium plate fin / copper tube 3 1,6 0,107 S ,6 14,3 1132/04A VAC~50Hz 68mA CH23 IT 2 1,2 250 VAC-200 VDC 30 SQ-136 AC 220V, 50 Hz, 6W 1440 ± 5% OFF ON 42 ± 1 33 ± 1,5 250 V - 6A B OPERATING RANGE Cooling only model Cooling Dry Heat pump model Cooling Heating Dry Temperature Maximum Minimum Maximum Minimum Temperature Maximum Minimum Maximum Minimum Maximum Minimum Indoor air intake temp. 32 C DB/ 23 C WB 19 C DB/ 14 C WB 32 C BS/ 80% R.U. 16 C BS/ 80% R.U. Indoor air intake temp. 32 C DB/ 23 C WB 19 C DB/ 14 C WB 27 C DB // 32 C BS/ 80% R.U. 16 C BS/ 80% R.U. 5

7 C DIMENSIONAL DATA 6

8 D ARGO 245SCH2O Cooling model ARGO 235HPH2O Heat pump model Conditions: Power source 230 V Hz - Single phase Indoor air velocity High speed Cooling characteristics Indoor relative humidity 48% Capacity (%) COOLING CAPACITY Tamb 19 C 80 Tamb 27 C 75 Tamb 32 C INLET WATER TEMP - C Power input (%) CAPACITY - %W POWER INPUT - %W POWER INPUT INLET WATER TEMP - C Tamb 19 C Tamb 27 C Tamb 32 C E.E.R. (%) 130 EER EER - %W/W INLET WATER TEMP - C 7 Tamb 19 C Tamb 27 C Tamb 32 C

9 E PERFORMANCE CHARTS SC and HP2 ARGO 245SCH2O Cooling model ARGO 235HPH2O Heat pump model 140 MOISTURE REMOVAL MOISTURE REMOVAL - %l/h INLET WATER TEMP - C Tamb 19 C Tamb 27 C Tamb 32 C 130 CORRECTION FACTOR % WATER FLOW RATE - l/h CAPACITY EER INPUT MOISTURE 8

10 F PERFORMANCE CHARTS heat pump1 ARGO 235HPH2O Heat pump model Conditions: Power source 230 V Hz - Single phase Indoor air velocity High speed Heating characteristics Indoor relative humidity 48% capacity capacity - %W Tamb 15 C Tamb 20 C Tamb 25 C inlet water temp - C power input power input - %W Tamb 15 C Tamb 20 C Tamb 25 C inlet water temp - C 9

11 G PERFORMANCE CHARTS heat pump2 ARGO 235HPH2O Heat pump model Heating characteristics Indoor relative humidity 48% cop / COP - %W/W Tamb 15 C Tamb 20 C Tamb 25 C inlet water temp - C correction factor % capacity power input cop water flow rate -l/h 10

12 H WATER SIDE PRESSURE DROP ARGO 245SCH2O Cooling model ARGO 235HPH2O Heat pump model WATER SIDE PRESSURE DROP PRESSURE DROP (kpa) WATER PRESSURE DROP(mm c.a.) WATER FLOW RATE(l/h) 11

13 I REFRIGERANT FLOW DIAGRAMS REFRIGERANT FLOW DIAGRAM AND WATER CONNECTION FOR COOLING MODEL ARGO 245SCH2O REFRIGERANT FLOW DIAGRAM AND WATER CONNECTION FOR HEAT PUMP MODEL ARGO 235HPH2O 12

14 GL FUNCTIONS 1 Cool Mode Operation In Cool mode, the operation of Compressor ( CM ), Solenoid Valve ( SV ) and Indoor Fan ( FMI ) are determined by the difference between the Room Temperature (RAT) and the Set Point Temperature (SPT) as in the graph above. Notes: a. In this graph, the FMI is operating in the"auto Fan Speed" setting. If the user has selcted the low, medium or high fan speed, the FMI will run constantly at that speed only. b. In addition to the value of ( RAT-SPT ), the operations of the relays are also controlled by protection delays.for example,(a) the minimum On/Off time of the ( CM ) is 3min respectively, and (b) the FMI can change speed only after it has operated at de same speed for 30sec.wen in autofan setting and 1sec. for H/M/L setting. 13

15 2 Heat Mode Operation The Heating mode operation is similar to the Cooling mode operation.the compressor CM,solenoid valve SV and fan motor indoor FMI are mainly controlled by the value of ( RAT SPT ).In the graph above, the FMI is operating in AUTO speed mode. Therefore, the FMI speed changes automatically according to the ( RAT - SPT ). NOTES 1. After the CM has stopped, the FMI runs for 30s in order to purge heat from the indoor coil. 2. The FMI will not be turned on until the indoor coil temperature is warm enough to prevent the supply of cool air (see COLD DRAFT PREVENTION feature for details). The indoor fan can change speed only after it has operated at the same speed for 30 sec if in AUTO and 1 sec for the other settings (High, Med, Low). 14

16 3 Auto (Cool/Heat) Mode Operation In Auto Mode, the unit switches automatically between the Auto Cooling and Auto Heating in order to maintain the room temperature (RAT) at the prescribed set point (SPT). The switching between the two modes is according to the above graph. Refer to the sections 1.COOLING MODE and 2.HEATING MODE for system operation details. 15

17 4 Dry Mode Operation Reducing the ambient temperature. This is done cycling ON and OFF indoor and outdoor units according to below. ROOM TEMP DRY LEVEL SPT+2 C LEVEL 0 Operation according to COOLING mode CM on < SPT+2 C LEVEL 1 FMO on SPT-1 C FMI switches between L and off (30 seconds) RV off CM switches 9 minutes off and 3 minutes on < SPT-1 C LEVEL 2 FMO switches 9 minutes off and 3 minutes ON 15 C FMI switches off and L during CM operation RV off CM off < 15 C DRY OFF ZONE FMO off FMI off RV off SPT = Set Point Temperature 5) Fan Mode Operation With this mode, the indoor fan is turned on while CM, FMO and RV stay off all the time. The user can select between 3 speeds: HIGH, MEDIUM and LOW. 6) Auto Fan speed With this option selected, the indoor fan speed changes automatically according to the difference between the detected air temperature (RAT sensor) and the set point (SPT): COOLING MODE 2 (RAT SPT): HIGH speed 1 (RAT SPT) < 2: MEDIUM speed (RAT SPT) < 1: LOW speed HEATING MODE 2 (SPT - RAT): HIGH speed (SPT - RAT) < 2: MEDIUM speed NOTE SPT = Set Point Temperature 16

18 7) Forcede mode means of the OPERATION button on the front panel. The operation modes can be selected pressing the button in a cyclic way (OFF COOL HEAT OFF ). The settings are: COOLING mode SET POINT temperature = 25 C FAN SPEED = HIGH HEATING mode SET POINT temperature = 21 C FAN SPEED = HIGH See also paragraph 15 for additional details. 8) Protection operations in Cool and Dry Mode 8.1 Freeze-up This protection prevents ice formation on the indoor coil heat exchanger. The protection is activated by the indoor coil temperature (ICT sensor) and only after 6 minutes of compressor operation. This protection acts in 2 levels: LEVEL 1 INDOOR FAN SPEED: ANY (as selected from remote controller) COMPRESSOR: ON OUTDOOR FAN: cycling (30 seconds ON 30 seconds OFF). DRAIN PUMP: operates according to paragraph 17 LEVEL 2 INDOOR FAN SPEED: ANY (as selected from remote controller) COMPRESSOR: OFF for at least 6 minutes and until ICT 8 C OUTDOOR FAN: OFF for at least 6 minutes and until ICT 8 C DRAIN PUMP: always ON ( stops when exiting the protection) The system exit this protection routine when ICT temperature rises above 8 C. 17

19 9) Protection operations in Heat Mode 9.1 Cold draft This feature prevents the supply of cold air forcing the indoor fan to a speed which cannot be changed by the user. As soon as the protection mode is exited speed can be changed manually through the remote controller. The protection acts in the following 18

20 9.2 Overheat This feature prevents the build up of high pressure in the indoor heat exchanger during heating 19

21 10) I Feel Function sensor equipped in the wireless remote controller (icon I FEEL shown on the display). This feature provides a personalised environment since the temperature can be detected where the remote controller is located. It is possible to de-activate this option pressing the I FEEL button on the remote controller. In this case the I FEEL icon is no longer displayed and room temperature is detected trough the sensor included in the indoor unit. 11) Night Function When this function is active, room temperature changes automatically to compensate for body temperature variations while sleeping. After 10 hours of operation system switches automatically to OFF state. This mode of operation is available both in COOLING and HEATING mode. 20

22 10) 12) Diagnostic With this feature is possible to have a visual signal that a trouble is occurring. In case of no troubles the LEDS status follows its normal function. NOTES The troubles are showed according a priority list that is in case of more than one trouble present, is always showed, at first, the one with the highest priority (1 2 3 etc). Sensor damaged means a situation where sensor is short-circuited or opened. In case of damaged sensors, the system (CM, FMO, FMI etc), if in OFF state, does not start. WRONG MODE SELECTED means a situation where the operating mode chosen with remote controller does not comply with the one allowed by jumpers settings. Priority TROUBLE LEDS status LD1(stby) LD2(opr) LD3(timer) 1 RAT damaged F O O 2 ICT damaged F F O 3 WRONG MODE F F F SELECTED Effects System does not operate O = LED off F = LED blinking 21

23 13) Jumpers configuration Unit is shipped with jumpers set according to the following table: JUMPER STATUS JP1 open JP2 open for H/P models - closed for other versions JP3 open JP4 closed JP5 closed 22

24 14) CONTACTS FOR BUILDING AUTOMATION INPUT CONTACT (J4 - green) - AVAILABLE ONLY IF "BOILER CONNECTION KIT" IS NOT INSTALLED The status of this input affects system operation according to the following: Contact OPEN : system does not operate (always OFF) inputs from wireless remote controller are not processed Contact CLOSED: system operates in the normal way according to the inputs coming from wireless remote controller OUTPUT CONTACT (J12) This connector is directly tied to the contact (normally open) of a power relay which activates every time the following alarm condition occur: RAT damaged ICT damaged In this case when alarm happens, on poles 1 and 3 of J12 connector, 220 VAC-50Hz are available. Max electrical load: 1A- 240VAC 23

25 15) Maintenance address to each unit in order to avoid operation conflicts. Address is set acting on the dip-switches located on the indoor PCB and on the remote controller. The PCB settings must match the corresponding ones on the wireless remote controller How to change address of the air conditioner Dip switch is located on the indoor PCB near the buzzer. Set the PCB to the address desidered UNIT SETTINGS ADDRESS SW1 SW2 1 off off 2 off on 3 on off 4 on on As default switches SW1 and SW2 are in off status (PCB factory state). How to change address on Remote Control Unit Dip switch is located on the battery compartment. 1) Pull out the door and remove the batteries. 2) Set the switch SW1 and SW2 according to the indoor PCB settings (do not act on SW3 and SW4) 3) Insert the batteries and pull on the door As default switches SW1 and SW2 are in off status (remote controller factory state). 24

26 16) Manual Unit Control and Led indicators The push button switch and the LED indicators on display panel let the user to control the unit operation without a R/C (Remote Controller). Their operations are provided below. Push Button Switch : Use to cycle the operation mode of the A/C unit among COOL, HEAT and OFF modes, without using the R/C. OPERATION BUTTON Every time this switch is pressed, the next operation mode is selected, in order: - Off => Cool mode => Heat mode => Off => (for heat pump model) - Off => Cool mode => Off => (for cooling only model) - The A/C will start in High fan speed. The temperature setting is 25 C for cooling and 21 C for heating mode. WARNING: the OFF position does not disconnect the power. Use the main power switch to turn off power completely. Led indicators : TIMER LAMP STANDBY LAMP OPERATION LAMP 1. Lights up during Timer operation. 1. Lights up when the Air conditioner is connected to power and ready to receive the Remote Control command. 2. Blinks continuously in case of any thermistor failure. 1. Lights up in Operation mode ( Note: OFF in standby mode). 2. Blinks for 0,5 sec., to announce that a R/C infrared signal has been received and stored. 3. Blinks continuously in case of any thermistor failure. 4. Blinks continuously in case of FS (Float Switch) trips for high water level. TIMER+STBY+OPR LAMP 1. Blinks continuously in case of wrong mode selected. Recovery from Power Failure 25

27 17 Ws Imput Switch The WS switch status (open/closed) rules system operation in two different way WATER FLOW-RATE MODE This mode is available when the WS_FLG parameter is set to 2 (water flow rate type). Drain pump is not present. WS status affects system operation only when unit is ON and according to the following chart: 26

28 M ELECTRIC WIRING DIAGRAMS 1- Cooling only model ARGO 245SCH2O LEGENDA PCB Controller board SW-IND-ASSY Indicator assy FMI Indoor fan motor TH1-2-4 Thermistor RL1 Power relay TP Terminal plate CM Compressor motor HWC Hot water control OLR Overload relay TM Water min temperature thermostat SV Solenoid valve EWV Electrically operated water valve C1-2 Capacitor FLP Flap motor HT High pressure switch F1 Fuse F Flow switch 27

29 2- Heat pump model ARGO 235HPH2O LEGENDA PCB Controller SW-IND-ASSY Indicator assy FMI Indoor fan motor TH1-2-4 Thermistor RL1 Power relay TP Terminal plate CM Compressor motor HWC Hot water control OLR Overload relay TM Water min temperature thermostat SV Solenoid valve EWV Electrically operated water valve C1-2 Capacitor FLP Flap motor HT High pressure switch F1 Fuse F Flow switch 20S 4-way valve 28

30 N 29

31 C 30

32 D 2) 31

33 E 32

34 Unit still does not run Unit still does not run 33

35 F Only if IFEEL is selected Temperature difference between suction and discharge air is large enough (approx. 15 C or more) install an additional unit G Only if IFEEL is selected 34

36 H RT RT 35

37 O REFRIGERANT CHARGE REFRIGERANT CHARGE R410A ARGO 245SCH2O 360 g ARGO 235HPH2O 470 g IMPORTANT When recharging the unit please use the high-pressure service pipe. Preliminary operation after refrigerant charge To distribute the oil to all the moving/sliding portions, run the compressor for at least 3 seconds within 15 minutes after refrigerant charge 36

38 P 37

39 38

40 Q BOILER CONNECTION KIT Hot water coil Typical installation Existing water connections By installer 1/2" Gas Female diameter Electric water valve Controller By installer Boiler connection Kit Air conditioner unit 1) SPECIFICATIONS Power source 230 V ~ 50 Hz Capacity at standard conditions Power input W W Fan speed Standard conditions: Ambient temp. C 3 ( Hi - Me - Lo ) 20 Fan speed High Inlet water temp. C 70 T water K 10 Water coil only P water kpa 0,7 ( 70 mmh2o) water flow l/h 155 ( 2,6 l/min.) Valve and tubes P water kpa 2,9 ( 290 mmh2o) including water flow l/h 190 ( 3,1 l/min.) OPERATING LIMITS Max temperature inlet hot water C Max pressure bar C 10

41 2) PERFORMANCE CHARTS Performance on different conditions Capacity ruduction factor : High speed = 1 ; Med. speed = 0,96 ; Low speed = 0,93 Capacity 140% 120% 70 C inlet water temp Pressure drop kpa 100% 7 60 C 6 80% 5 60% 50 C 4 40% 20% % t = (inlet water temp.) - (outlet water temp.) 0 Pressure drop kpa WATER FLOW AND PRESSURE DROP ( 3 WAY VALVE AND PIPE INCLUDING ) / Water flow 350 l/h

42 3) COMPONENT SPECIFICATIONS ( Boiler connection kit ) CONTROLLER ( HWC ) Type Controls Thermostat THERMISTOR ( ROOM SENSOR ) TH4 Type Resistance (at 25 C) as alternative CONTROLLER ( HWC ) Type Controls Thermostat THERMISTOR ( ROOM SENSOR ) TH4 Type Resistance (at 25 C) LIMIT WATER THERMOSTAT ( TM ) Electrical rating Control setting Differential WATER ELECTRIC VALVE ( EWV ) Electric Thermal Actuator Supply voltage Power consumpion: Nominal force Nominal stroke Full stroke time at 50 C 3-way Forged brass valve Body Type Threaded Male Connection Close-Off Pressure Water HEAT EXCHANGER COIL Coil Rows Fin pitch Setting Differential kω Setting Differential Type kω Continous Start-up Actuator stem Actuator stem Type Type kpa mm Face area m 2 Threaded Male Connection 000TSA Manual 6 C ±1 C 30 C ±1 C 1K STLNGY050 4,7 ±2% Manual 6 C ±1 C 30 C ±1 C 1K ,8 ±2% 10(1,6) A - 250Vac Autoreset Open : 31 C ±3 C - Close: 42 C±4 C 11K VA VAC ± 15% 2,5 W 36 W (150 ma) max 125 N 4,5 mm extends : 60 sec retract : 10 min VG-5510EC 3-way NO bypass 1/2" Gas 100 Aluminium plate fin / Copper tube 1 2,0 0,102 1/2" Gas 41

43 4) HYDRAULIC CONNECTIONS AND VALVE 43

44 Via Varese, Gallarate - Va - Italy Tel Fax

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL REVE DCI HPL/SCL 0.8180.615.01 06/2012 Pagina 1 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3 2) Major Component specifications 4 B OPERATING RANGE 6

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL HEAT PUMP MODELS INDOOR UNIT: MPAF188R5TAA MPAF228R5TAA COOLING MODELS MPAF188C5TAA MPAF228C5TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MPAF188R5TAA 38.7104.033

More information

SPLIT SYSTEM AIR CONDITIONER

SPLIT SYSTEM AIR CONDITIONER TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: MRAF99R5IAA MRAF129R5IAA MPAF99R5IAA MPAF129R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MRAF99R5IAA 38.7104.065 MRAF129R5IAA 38.7104.062 MPAF99R5IAA

More information

SPLIT SYSTEM AIR CONDITIONER

SPLIT SYSTEM AIR CONDITIONER TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: MPAFIA0R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MPAFIA0R5IAA 38.7104.074 0.8180.590.01 10/2012 IMPORTANT! Please read before installation

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: ASR609CL ASR612CL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. ASR609CL 387006970 ASR612CL 387006971 0.8180.250.0 05/2002 IMPORTANT! Please read

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA- TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA- SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MCAF72R5TA- 387104015 MCAF92R5TA- 387104016 MCAF122R5TA- 387104017

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW22AL 387030005 AW28AL 387030006 AW38AL 387030007 AW42AL 387030094 0.8180.467.0

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE726SCL AE752SCL AE71SCL3 AE735SCL AE752SCL3 AE100SCL3 AE764SCL3 AE125SCL3 SPLIT SYSTEM AIR CONDITIONER Model No. AE726SCL AE735SCL AE752SCL AE752SCL3 AE764SCL3

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT:. TRIAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.102. 0.8180.611.02 09/2012 IMPORTANT! Please read before installation This air conditioning

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF94R5 CAF124R5 SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. CAF94R5 387106979 CAF124R5 387106980 0.8180.361.0 07/2005 IMPORTANT! Please read before

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KS30NKU CS-KS36NKU Product Code No. 852 360 86

More information

SPLIT SYSTEM AIR CONDITIONER

SPLIT SYSTEM AIR CONDITIONER TECHNICAL DATA & SERVICE MANUAL Indoor Unit MCA201R MCA271R MCA351R Outdoor Unit GR201R GR271R GR351R SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT 0.8180.263.1 06/2002 Important! Please Read Before

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AE22AH 387031006 AE28AH 387031007 AE38AH 387031008

More information

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A TECHNICAL & SERVICE MANUAL SAP K181A SAP K241A + SAP C181A + SAP C241A FILE NO. Destination: Australia SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. SAP K181A S 1 852 068 06 SAP K241A

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS7 & PNRXS87 + CH7 XHS87 & PNRXS87 + CH87 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS7 (PNRXS87) XHS87 (PNRXS87)

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: DUAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.098 38.7107.103 38.7107.106 0.8180.597.03 09/2012 IMPORTANT! Please read before installation

More information

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER TECHNICAL DATA & SERVICE MANUAL Outdoor Unit GR54M2C Indoor Unit MCA27MC (X2) MULTI-SPLIT SYSTEM AIR CONDITIONER Indoor Unit Outdoor Unit MCA27MC GR54M2C 0.8180.195.0 04/2001 IMPORTANT! Please Read Before

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 9,000BTU / h 11,900BTU / h 17,500BTU

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K303A + SAP C303A FILE NO. Destination: Australia SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. SAP K303A A 1 852 098 83 Outdoor Model No.

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL TECHNICAL & SERVICE MANUAL INDOOR UNIT: MCAF94MR5IAA MCAF124MR5IAA MCAF184MR5IAA MCAF244MR5IAA NOV.2003 Destination: General area (50Hz) Europe (50Hz) Australia (50Hz) General area (60Hz) DC INVERTER MULTI-SYSTEM

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL AWR222CLE - AER222SC AWR222CLE - AER222SC3 SPLIT SYSTEM AIR CONDITIONER 0.8180.076.0 03/00 Important! Please Read Before Starting This air conditioning system meets strict safety

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO. TECHNICAL & SERVICE MANUAL SAP K301AH + SAP C301AH FILE NO. Destination: Australia SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. SAP K301AH S 1 852 071 34 Outdoor Model No. Product Code

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL MCAF88R5I + GRF86R5I MCAF48R5I + GRF46R5I FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. MCAF88R5I MCAF88R5IAA

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS0971 + C0971 + CL0971 KS1271 + C1271 + CL1271 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS0971 KS1271 Product

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL MCAF94R5IAA + GRF97R5I MCAF124R5IAA + GRF127R5I FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. MCAF94R5IAA

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510 TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU

More information

MULTI-SPLIT SYSTEM AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP KM97AHA ( 2) + SAP CM1827AHA FILE NO. Destination: Australia MULTI-SPLIT SYSTEM AIR CDITIER Indoor Model No Product Code No. Outdoor Model No. Product Code No. SAP KM97AHA

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : KMS0772 FILE NO. KMS0972 KMS1272 KMS1872 KMS2472 Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

Service Manual. Compact Series REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12

Service Manual. Compact Series REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12 Service Manual Compact Series Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12 REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP SEPTEMBER - 2005 LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

Item No. (Standard/Opposite Hand) /

Item No. (Standard/Opposite Hand) / SPECIFICATIONS Model HWP 59RKS Item No. (Standard/Opposite Hand) 509-059-001 / 509-059-011 Cooling capacity (net) to AS/NZS 3823 T1 5.7 kw Heating capacity H1 5.4 kw Electrical input - cooling 1.6 kw Electrical

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax: Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE

More information

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : MCAF78MR5I MCAF98MR5I MCAF128MR5I MCAF188R5I MCAF248R5I FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : MPAF90MRI MPAF0MRI MPAF80RI MPAF0RI DC INVERTER MULTISYSTEM AIR CONDITIONER Capacity Indoor Model No..6 kw.0 kw. kw 7.0 kw MPAF90MRI MPAF0MRI MPAF80RI MPAF0RI Wall

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Fast Track Troubleshooting Models Covered: RF266AD**/XAA French Door Refrigeration IMPORTANT SAFETY NOTICE For Technicians Only This service data sheet is intended for use by persons having electrical,

More information

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2 Order No: MAC008C Room Air Conditioner CS-E9BKP CU-E9BKP5 CS-EBKP CU-EBKP5 CONTENTS Page Page Features Functions Product Specifications 6 Dimensions 0 5 Refrigeration Cycle Diagram 6 Block Diagram 7 Wiring

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-04004-3 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKHP-E3 / RAS-13UAH-E3 RAS-10UKHP-E3 / RAS-10UAH-E3 RAS-07UKHP-E3 / RAS-07UAH-E3 RAS-13UKP-E3 / RAS-13UA-E3 RAS-10UKP-E3 / RAS-10UA-E3

More information

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

WALL MOUNTED TYPE ROOM AIR-CONDITIONER TECHNICAL MANUAL & PARTS LIST DRAFT WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK50HE-S, SRK56HE-S (Split system, air cooled cooling only type) SRK50CE-S, SRK56CE-S

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

INVERTER SPLIT SYSTEM AIR CONDITIONER

INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP-KRV91EH + SAP-CRV91EH FILE NO. INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. Outdoor Model No. Product Code No. Destination SAP-KRV91EH 1 852 065

More information

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Technical manual NIBE AG-AA10 Single split air to air heat pump

Technical manual NIBE AG-AA10 Single split air to air heat pump Technical manual NIBE AG-AA10 Single split air to air heat pump TABLE OF CONTENTS 1 SCOPE... 4 2 DIMENSIONAL DATA AND EXTERIOR APPEARANCE... 5 3 TECHNICAL SPECIFICATIONS... 7 4 REFRIGERANT CIRCUIT... 10

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Fast Track Troubleshooting Models Covered: RS263BBBB/XAA RS263BBSH/XAA RS263BBWP/XAA RS265LBBP/XAA RS265LBWP/XAA SxS Refrigeration Notice: Bulletin on parts change Thermal Fuse to Bi-Metal Publication

More information

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE -(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : SAP-CMRVEH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 0.0kW Outdoor Model No. SAP-CMRVEH-F Product Code No. 8 8 SAP-CMRVEH

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

Service Manual. Alpha Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Alpha 9 Alpha 17 DF. ONG3-17 (Alpha)

Service Manual. Alpha Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Alpha 9 Alpha 17 DF. ONG3-17 (Alpha) Service Manual Alpha Series Indoor Units Alpha 7 Alpha 9 Alpha 9 DF Alpha 12 Alpha 12 DF Alpha 17 Alpha 17 DF Outdoor Units CON 7 (Alpha) GCN 9 (Alpha) ONG3-9 GCN 12 (Alpha) ONG3-12 ONG3-17 (Alpha) REFRIGERANT

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Models Covered: RF266AA**/XAA RF266AB**/XAA RF266**/XAA French Door Refrigeration NOTICE: RF266AA & AB** 01/09 Parts Change: Refer to bulletin. All Water Tank Parts Forced Mode: Press the Pwr Freeze Fridge

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-05009-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E4 / RAS-24UAH-E4 RAS-18UKHP-E4 / RAS-18UAH-E4 RAS-24UKP-E4 / RAS-24UA-E4 RAS-18UKP-E4 / RAS-18UA-E4 RAS-24UKP-AR4 / RAS-24UA-AR4

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

Service Manual. LEX Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units LEX 7 ONG 7 LEX 9 ONG 9 LEX 12 ONG 12 LEX 14 ONG 14

Service Manual. LEX Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units LEX 7 ONG 7 LEX 9 ONG 9 LEX 12 ONG 12 LEX 14 ONG 14 Service Manual LEX Series Indoor Units Outdoor Units LEX 7 ONG 7 LEX 9 ONG 9 LEX 12 ONG 12 LEX 14 ONG 14 REFRIGERANT R410A COOLING ONLY HEAT PUMP JANUARY - 2006 LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features

More information

Engineering Data Manual

Engineering Data Manual Engineering Data Manual Residential Split Low Silhuoette LSN DCI Inverter Series Indoor Units LSN 25 DCI LSN 35 DCI LSN 50 DCI LSN 60 DCI LSN 72 DCI Outdoor Units ONG 25 DCI ONG 35 DCI ONG 50 DCI GC 60

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION... 4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

II PCV1 Features

II PCV1 Features II-15-24-43-PCV1 FLOOR STANDING CABINET TYPE HEAT PUMP COOLING CAPACITY: 4,6 kw - 12,6 Kw HEATING CAPACITY: 4,7 kw - 13,0 kw R410A Scroll The new Interklima floor standing CABINET type heat pumps are the

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

XLF Series REFRIGERANT R410A HEAT PUMP COOLING ONLY SM XLF 1-A.1 GB

XLF Series REFRIGERANT R410A HEAT PUMP COOLING ONLY SM XLF 1-A.1 GB XLF Series Indoor Units XLF 9 XLF 12 Outdoor Units ONG3-9 ONG3-12 REFRIGERANT R410A HEAT PUMP COOLING ONLY AUGUST 2008 LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES Note: Changes in the pages are indicated

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information