NEW!! New for 2011/12!! Oil Burner Motors Pg.8. Direct Drive Blowers!! Pg.12,13,14. NEW OEM Replacement Motors!!

Size: px
Start display at page:

Download "NEW!! New for 2011/12!! Oil Burner Motors Pg.8. Direct Drive Blowers!! Pg.12,13,14. NEW OEM Replacement Motors!!"

Transcription

1

2 New for 011/1!! New Oil Burner Motors Pg.8 NEW!! New Direct Drive Blowers!! Pg.1,13,1 NEW OEM Replacement Motors!! Part # OEM Name Page # FB-RFB1 Armstrong - JA1N111, FB-RFB19 Bradford White - Fasco A19, , AO Smith FB-RFB580 Consolidated Industries - JAIN107, 90950, FB-RFB31 Consolidated Industries - JAIN118, 30590, FB-RFB570 Consolidated Industries - UE JA1P08, FB-RFB57 Consolidated Industries - UE JA1P090, FB-RFB7 Heil Quaker - A0, 107, X FB-RFB571 ICP , , A19, , FB-RFB95 Lennox - W95, 31L5501 FB-RFB98 Lennox - G Mid Eff. 11K98 Kit FB-RFB99 Lennox - G Mid Eff. 11K99 Kit FB-RFB15 Trane FB-RFB150 Trane - A150, FB-RFB58 Williamson Furnace - A080, , 0-58, S FB-RFB118 Williamson Furnace - A118, , , X Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

3 5.5" Direct Drive Features 8 Frame 5.5" Diameter Open Enclosure Mounting: Stud, Strap & Base (Resilient Rings) 0 Hz Sleeve Bearing Shaft: 1/".0" Reversible Permanent Split Capacitor (P.S.C.) 0" Coloured Electrical Leads Insulation Class B Thermally Protected + DD-131 llustrated Month Warranty 8 Frame - Speed - Multi-HP - Direct Drive Part # HP Volts Amps Cap. SPD/RPM Rotation A Dim. Bearing Shaft DD-131 1/ /370 /1075 Revers..0" Sleeve 1/" " Capacitor Not Included Cross Reference Rotom HP Voltage AO Smith Carrier Coleman Emerson Lennox ICP GE Marathon Rotom DD-131 1/3 1/ 1/ 1/7 115 DL10 DL103 HC1SE117 HC1SE11 P P P P LFM X003 R3583 R3585 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 3

4 Direct Drive 5.5" Direct Drive Replacement Motors Features Less Inventory Required! Versatile! Time Saver! Easy Installations! Energy Efficient Different Capacitor/Speed Combos Designed for 370V Cap Reversible Rotation Resilient Rings Extended Thru Bolts Automatic Protector Class B Insulation Supplied Free In 8 Frame Every Box Single Phase Continuous Duty-Over Air All-Purpose Capacitor Multi-Rating Capacitor Mounts by Belly Band, Thru Bolts 5, 7.5, 10, 1.5 & 15 MFD or Shell Holes Rheem Mounting Holes in Shell 0 Hz Part # HP Spd. RPM Volt Amps Capacitor (370V) Bearing Leads Dia Shaft 1/ All mfd 1/3 All.7 R-R300 1/ Lo, Med-Lo, Med-Hi Sleeve ".8" 1/" 5" 5 mfd 7.5* 1/5 Low, Med-Lo 3. 1/ Lo. 1/ All mfd 1/3 All 3. R-R301 1/ Lo, Med-Lo, Med-Hi Sleeve ".8" 1/" 5" 5 mfd 7.5* 1/5 Lo, Med-Lo 1.8 1/ Lo 1.3 3/ All 9.1 1/ All.8 10 mfd R-R30 1/3 All Ball 38".8" 1/" 5 1/" 1/ Lo, Med-Lo, Med-Hi mfd 7.5* 1/5 Lo, Med-Lo.3 3/ All 3.9 1/ All mfd R-R303 1/3 All Ball 38".8" 1/" 5 1/" 1/ Lo, Med-Lo, Med-Hi.3 5 mfd 7.5* 1/5 Lo, Med-Lo.0 * Motor is approximately 10% stronger and has higher starting torque for 1/, 1/5, 1/ and 1/3 HP rating with the 7.5 mfd 370VAC capacitor. Cross Reference Open Drip Proof 0 C Ambient Rotom Emerson Genteq Fasco Marathon A.O. Smith R-R D835 X077 FDL001A R-R D833 X073 FD000A R-R D83 X07 FDL00A R-R D833 X075 FD001A Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

5 Direct Drive Motors Direct Drive Motors Features 8Y Frame 5.5" Diameter Open Enclosure Mounting: Stud, Strap & Base (Resilient Rings) 0 Hz Sleeve Bearing Shaft:.0" 1/" Reversible Permanent Split Capacitor (P.S.C.) 0" Coloured Electrical Leads (except where noted) 5 C Ambient (except where noted) Insulation Class B Thermally Protected 5 C Ambient Month Warranty + 9-A817 Torsion Flex Bracket 5.0" & 5.5" Dia. 9" & 10" Bolt Circles 9-A8550-5" Diameter 9-A " Diameter 9" & 10" Bolt Circles 115 & 08/30 Volt, 3 Speed, 1075 RPM, Reversible Rotation Cross Reference Rotom HP Voltage AO Smith Diversitech Emerson Fasco Embraco GE Marathon UE Rotom DD / 115 DL10 WG D71 E X R3583 DD-358 1/ 08/30 D10 WG D75 E0 358 X R358 DD /3 115 DL103 WG D77 E X00 53 R3585 DD-358 1/3 08/30 D103 WG D93 E0 358 X R358 DD / 115 DL105 WG D701 E X R3587 DD / 08/30 D105 WG D703 E X R3588 DD / 115 DL107 WG D78 E X R3589 DD / 08/30 D107 WG D79 E X R3590 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 5.5" Diameter for 1/ HP and above 9-A855-9" Bolt Circle 9-A " Bolt Circle HEAVY DUTY Part # HP Volts Amps Cap. SPD/RPM Rotation Body Bearing Shaft DD / /370 3/1075 Revers.." Sleeve 1/".0" DD-358 1/ 08/30. 5/370 3/1075 Revers.." Sleeve 1/".0" DD-3585* 1/ /370 3/1075 Revers..37" Sleeve 1/".0" DD-358 1/3 08/30.9 5/370 3/1075 Revers..8" Sleeve 1/".0" DD-3587* 1/ /370 3/1075 Revers. 5.5" Sleeve 1/".0" DD / 08/ /370 3/1075 Revers. 5.3" Sleeve 1/".0" DD / /370 3/1075 Revers. 5.8" Sleeve 1/".0" DD-3590* 3/ 08/ /370 3/1075 Revers. 5.37" Sleeve 1/".0" *Note: " leads & 0 C Amb. Capacitor Not Included 5

6 5.5" Unit Heater Motors Features 8 Frame 5.5" Diameter Totally Enclosed Mounting: Stud Pattern 0 Hz Ball Bearing Shaft: 1/" 3." Reversible Permanent Split Capacitor (P.S.C.) 0 C Ambient Insulation Class B Thermally Protected Month Warranty + Optional Base UH-UHK Optional Mounting Base For UH- Series Unit Heaters. Includes Base, Brackets & Resilient Rings. Unit Heater Part # HP Volts Amps Cap. RPM Rotation A Dim. Bearing Shaft UH-903 1/ /370 1/1075 Revers..5" Ball 1/" 3." UH / /370 1/1075 Revers..5" Ball 1/" 3." UH-903 1/ /370 1/1075 Revers..5" Ball 1/" 3." Capacitor Included Cross Reference Rotom AO Smith Emerson Fasco GE Marathon UE UH-903 UH101, US101, US101NB 903 D83 30 X30, X30 177, 79 UH-9035 UH10, US10, US10NB 9035 D X303, X307 5, 73, 750 UH-903 UH103, US103, US103NB 903 D73 31 X30, X , 751 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

7 Belted Fan Motors Features 8 Frame 5.5" Diameter Open Drip Proof Resilient Ring & Base Included 0 Hz Sleeve Bearing Shaft: 1/" 1.5" W/ Flat Reversible Split Phase 5 C (113 F) Ambient Insulation Class B Thermally Protected Month Warranty A + BF-701 Belted Fan - One Speed Part # HP Volts Amps S.F. RPM Rotation A Dim. Bearing Shaft BF-701 1/ /175 Revers..5" Sleeve 1/" 1.5" BF-70 1/ /175 Revers..5" Sleeve 1/" 1.5" BF-708 1/ /175 Revers..75" Sleeve 1/" 1.5" Cross Reference Rotom AO Smith Emerson Fasco GE Marathon UE Rotom BF-701 GF0 80CV D00 701, H701 D17, B0, B303 - R80 BF-70 GF03 81CV - 70, H711 D13, B07 - R81 BF-707 GF03B 888 D00 8, H15 B305, B703 90, 91,9 R888 BF-708 GF05 15C D1, B08 - R15 BF D00 8, H703 B307 - R887 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 7

8 Split Phase, 0Hz, Shaded Pole Part # HP Volts Amps Service Factor NEW!! Oil Burner Motors Features 8M and 8N Flange Mounting Open & Totally Enclosed External reversing Switch (most models) Sleeve Bearing Manual Reset Overload SPD/RPM Rotation Body Frame Bearing Shaft Comment T-R1 1/ /175 Rev. 5." 8N Sleeve 1.8" 1/" 11" Leads T-R10 1/ /175 Rev. 5." 8N Sleeve 1.8" 1/" 0" Leads T-R78 1/ /175 Rev. 5." 8N Sleeve 1.8" 1/" T-R097 1/ /350 Rev. 5.93" 8N Sleeve 1.88" 1/" 0" Leads, open shaft end bracket, rotation switch. 0" Leads, open shaft end bracket, rotation switch. T-R3083 1/ /350 Rev. 5.7" 8M Sleeve 1.8" 1/" 15" Leads, rotation switch. T-R58 1/ /350 CCW 5.7" 8M Sleeve 1.8" 1/" T-R30 1/ /350 CW 5.97" 8M Sleeve 1.8" 1/" 15" Leads, open shaft end bracket Beckett 1805U, 10.5" Leads, open shaft end bracket T-R350 1/ /175 Rev. 5.7" 8N Sleeve 1.8" 1/" 0" Leads T-R35 1/ /175 Rev. 5.7" 8N Sleeve 1.8" 1/" 0" Leads, open shaft end bracket, rotation switch. T-R351 1/ /350 Rev. 5.97" 8M Sleeve 1.8" 1/" 0" Leads, rotation switch. T-R3579 1/ /175 Rev..7" 8N Sleeve 1.8" 1/" 0" Leads, rotation switch. T-R30 1/ /350 Rev..7" 8N Sleeve 1.8" 1/" T-r33 1/ /175 Rev..7" 8N Sleeve 1.8" 1/" 0" Leads, open shaft end bracket. 0" Leads, open shaft end bracket. T-R303 1/ /175 Rev. 9." 8N Sleeve 1.88" 1/" Terminal board T-R38 1/3 115/30./ /350 Rev..7" 8N Sleeve 1.8" 1/" T-R788 1/3 115/30 5./ /350 Rev. 9.91" 8N Sleeve 1.88" 1/" T-R37 1/ 115/30./ /350 Rev..7" 8N Sleeve 1.8" 1/" T-R3105 1/ 115/30 7.3/ /350 Rev. 10.1" 8N Sleeve 1.88" 1/" T-R317 3/ 1.5" Leads, open shaft end bracket. Cap start, open shaft end bracket, terminal board 1.5" Leads, 50/0Hz, open shaft end bracket. Cap start, terminal board, open dripproof Cap start, terminal board, 115/ / /350 Rev. 8.75" 8CZ Ball.0" 5/8" open constr. 5/8" keyed shaft PSC Oil Burner Motor - Direct Beckett Replacement U NEW!! PSC, 0Hz Part # HP Volts Amps Service Factor SPD/RPM Rotation Body Frame Bearing Shaft Comment T-R1805U 1/ /350 CW.59 8M Ball 1.8" 1/" PSC, open dripproof, automatic protector 8 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

9 Circulator & Booster Pump Motors Armstrong / B&G Direct Replacement Single Shaft Single Speed 175 RPM 115/30/0/575 Volts Resilient Rings for Base Mount Models Open Construction Reversible Typical Applications : Hot Water Boiler & Booster Pumps Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. CP-R1350 Part # HP Volts Fig. Bearing Cross Reference CP-R1350 1/ Ball , , CP-R1311 1/1 115 Sleeve NEW! Taco Replacement CP-R130 1/ Sleeve NEW! CCW, 5KH3EG19GA, 8S17D108 CP-R1310 1/8 115 Sleeve OBG00 CP-R1351 1/ Ball , CP-R135 1/ Ball , , CP-R Ball , , / CP-R1 115 Ball CP-R Ball , , /3 CP-R1 115 Ball CP-R /30 7 Ball , 1110 CP-R138 30/0 8 Ball , 00, 03, , / CP-R Ball , CP-R /30 9 Ball , 1110 CP-R13 115/30 7 Ball , CP-R /0 8 Ball , CP-R Ball , / CP-R1 115/30 9 Ball , 033, CP-R170 30/0 10 Ball , CP-R Ball , 0, 07, CP-R /30 7 Ball 817-0, CP-R /0 8 Ball , CP-R Ball , CP-R13 115/30 9 Ball , 08, 031, CP-R171 30/0 10 Ball , CP-R Ball , 08, 031, CP-R /30 7 Ball , CP-R / 30/0 8 Ball , 1909 CP-R Ball , Pump Couplers Easy Links - Spirolink T CP-R1311 CP-R130 T-1003 CP-R1310 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) CP-R135 Fig. 7 Fig. 8 Fig.9 Fig. 10 CP-R1 CP-R1373 CP-R1359 CP-R13 CP-R171 Part# Specification Description T /" 1/" 1/ to 1/3 HP Easy Link T-10010SL 1/" 1/" Spirolink T /" 1/" or 1/" 5/8" 1/ to 3/ HP Easy Link T-1003SL 1/" 1/" or 1/" 5/8" Spirolink T-1003SL 1/" 5/8" or 5/8" 5/8" Spirolink T-1005SL 1/" 5/8" or 5/8" 5/8" Taco 9

10 Flue Exhaust Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Part # HP Spd/RPM Amps Volts Rot Shaft Body Type Mntg Comment Fig FM-RFM50 1/00 1/ /30 C.C.W. 0.8"x1/".90 S.P. LEG Keeprite 50015K 1 FM-RFM1 1/0 1/ C.C.W..5"x1/" 5.80 S.P. STUD York B 5" leads FM-RFM 1/35 1/ /30 C.C.W. 3.9"x5/1".90 S.P. STUD Franklin 80137, Fasco D0, D08 3 FM-RFM10 1/35 1/ /30 C.W. 3.9"x5/1".90 S.P. STUD E.J. Walsh , Fedders, w/ centrifugal switch 3 FM-RFM1198 1/30 1/ C.W..3"x5/1" 3.0 S.P. LUGS Lennox 5J101 FM-RFM890 1/5 1/ /30 CCW.3"x5/1" 3.9 S.P. STUD Lennox 98G8901, FM-RFM5 1/0 1/ /30 C.C.W..3"x1/" 5.30 S.P. STUD Fedders S , U.E. 570 FM-RFM 1/0 1/ /30 C.W..3"x1/" 5.30 S.P. STUD Carrier HCAU700, U.E. 571 FM-RFM580* 1/0 1/ C.C.W. 1.9"x5/1" 3.50 S.P. LUGS HC7VE10, Univ. JAP053N, Bryant P51-307, U.E FM-RFM11* 1/0 1/ C.C.W. 1.5"x5/1" 3.0 S.P. 3 LUGS Clare Bros. M05 8 Carrier, York, Keeprite U53 FM-RFM53 1/0 1/ /0 C.W..1"x1/" 5.90 S.P. STUD Fasco , 5/1 Bushing FM-RFM 1/1 1/ C.W. 3.3"x5/1".80 PSC/ INC STUD ICP Carrier HC30GB0 9 FM-RFM80 1/1 1/ /08 /30 York , 701, REV. PLUG 1."x1/" 7.00 PSC/ INC STUD Carrier HC80001B, w/switch Carrier, York, U0 w/ Cent. Switch 5/1 Bushing M0 - Clare High Efficiency * Note: Without Centrifugal Switch FM-RFM3 1/1 1/ /0 C.C.W..3"x1/".0 S.P. STUD FM-RFM1* 1/15 1/ C.C.W. 1.3"x5/1".0 S.P. 3 LUGS Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

11 Flue Exhaust Motors Fig. 1 FM-RFM30 Fig. FM-RFM9 Fig. 3 FM-RFM3 Fig. FM-RFM10 Fig. 5 FM-RFM187 Fig. FM-RFM0 Fig. 7 FM-RFM78 Part # HP Spd/RPM Amps Volts Rot Shaft Body Type Mntg Comment FM-RFM30 1/1 1/ REV.PLUG.5"x1/" 7.00 PSC/INC Stud , 71 FM-RFM9 1/1 1/ /30 CCW.8"x5/1".30 SP Stud Keeprite 50193, FM-RFM3 1/10 1/ /30 CW.9"x5/1" 5.00 PSC/INC Stud ICP , JF1H09N Carrier HC30GB3 FM-RFM10 1/10 1/ /30 REV. 3.7"x1/" 7.10 PSC/INC Lugs Fasco D10, D1, Reznor FM-RFM187 1/10 1/ CW 8.8"x3/8".80 PSC/INC Stud York , , D1187 FM-RFM0 1/10 1/ REV..5"x1/" 7.00 PSC/INC Stud YVFM50, Fasco D1171 York FM-RFM78 1/9 1/ /30 REV. 3.3"x5/1".10 PSC/INC Stud RFM7&8, Reznor V, 3-08/30V * Note: Without Centrifugal Switch Cooling Fan Kits Part # Rotation Kits Description 9-FMK CW 1 3/" Diameter. 5/1" Hub I.D. with 1/" adapter. 9-FMK1 CCW () Spacers, () 10/3 & () 8/3 nuts. 9-FMK1 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 11

12 Direct Drive Blowers Fig.1 Fig. Fig.3 Fig. Fig.5 Fig. Fig.7 Fig.8 Fig.9 Fig.10 Fig.11 Fig.11 Part # CFM Spd/RPM Volts Amps Rot. Type Const. Bearing Comment Fig R7-RB0 50 1/ CW PSC Open Ball Grainger 1TDN7, C0 1 R7-RB / CCW SP Open Sleeve NEW! AO Smith 1 R7-RB3 0 1/ CCW SP T.E. Sleeve NEW! AO Smith 9 3 R7-RB 0 1/ / CCW SP Open Sleeve NEW! AO SMITH 93, FASCO 5077-D30, GRAINGER C01 R7-RB1 0 1/ CCW SP Open Sleeve NEW! AO SMITH 91, FASCO 5077-D500 R7-RB0 0 1/ CW SP Open Sleeve NEW! AO SMITH 970, FASCO 5077-D01 3 R7-RB5 5 1/ CCW SP Open Sleeve NEW! AO SMITH 9, FASCO 5078-D500, GRAINGER C3 R7-RB / CCW SP Open Sleeve NEW! AO Smith 989 R7-RB 71 1/ CW PSC T.E. Ball Franklin 701, 800, Electrohome EB 7 R7-RB / CW SP Open Sleeve Electrohome , EB75 8 R7-RB3 75 1/ CW PSC Open Ball Fasco B0 9 R7-RB / CW SP Open Sleeve NEW! AO SMITH 1 10 R7-RB / CW SP Open Sleeve NEW! AO SMITH R7-RB / CW SP Open Sleeve NEW! AO SMITH Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

13 Direct Drive Blowers Fig.1 Fig. Fig.3 Fig. Fig.5 Fig. Fig.7 Fig.8 Fig.9 Fig.10 Fig.11 Fig.1 Part # CFM Spd/RPM Volts Amps Rot. Type Const. Bearing Comment Fig R7-RB 100 1/ CW SP T.E. Sleeve Franklin 700, 80978, Electrohome EB 1 R7-RB / CW SP Open Sleeve Newmac 0001 EB3 w/ Variable Spd Switch R7-RB / CW PSC T.E. Ball Easy Radiant 3 R7-RB / CW SP Open Sleeve NEW! AO Smith 95 R7-RB / CCW SP Open Sleeve NEW! AO Smith 98, Fasco B0 5 R7-RB / CCW SP Open Sleeve R7-RB1 10 1/ / CCW SP Open Sleeve NEW! AO Smith 99, Fasco 5075-D500, GRAINGER C NEW! AO Smith 993, Fasco 5075-D30, Grainger C915 R7-RB / CW SP Open Sleeve Franklin 7001, R7-RB 1 1/ CW PSC Open Ball Grainger C, 1TDP7, Fasco R7-RB / CW PSC T.E. Ball Grainger 1TDR, C00, Fasco R7-RB / CCW SP Open Sleeve NEW! AO Smith R7-RB / CCW SP Open Sleeve NEW! AO Smith 58 R7-RB / CCW SP Open Sleeve NEW! AO Smith 971, Fasco B710, Grainger C75 R7-RB1 00 1/ CW SP Open Sleeve Franklin 8078, 80981, Electrohome EB1 1 R7-RB5 5 1/ CCW SP Open Sleeve AMU5, Airdex 1 11 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 13

14 Direct Drive Blowers Fig.1 Fig. Fig.3 Fig. Fig.5 Fig. Fig.7 Fig.8 Fig.9 Fig.10 Fig.11 Fig.1 Fig.13 Part # CFM Spd/RPM Volts Amps Rot. Type Const. Bearing Comment Fig R7-RB5 5 1/ CCW SP Open Sleeve Franklin 80, U.E.59, Fasco B57 1 R7-RB 5 1/ CCW SP Open Sleeve NEW! AO Smith 911, Fasco B57-, Grainger C89 R7-RB7 73 1/ CW PSC Open Ball Grainger C7, 1TDR3 3 R7-RB / CW SP Open Sleeve NEW! AO Smith 98, Fasco 5075-D500 R7-RB3 3 1/ CCW PSC Open Ball NEW! AO Smith 97, Grainger C93 5 R7-RB / CCW SP Open Sleeve NEW! AO Smith 9, Grainger C R7-RB 0 1/ CW SP Open Sleeve NEW! AO Smith 91, Grainger 5C507 7 R7-RB5 5 1/ CCW SP Open Sleeve Franklin 805, U.E.0, Fasco B57, Grainger C8 R7-RB / CCW SP Open Sleeve NEW! AO Smith 95 9 R7-RB / CCW SP Open Sleeve NEW! AO Smith 991, Fasco 5079-D R7-RB5 59 1/ CW PSC Open Ball Grainger 1TDT, C5, YJ3 11 R7-RB70 70 / CW PSC Open Sleeve NEW! AO Smith 959, Grainger 5C508 1 R7-RB / /30.00 CCW PSC Open Sleeve NEW! AO Smith 977, Fasco A Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

15 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Air 000 R3-R31 1/ SP 1550 CCW.7" 3.3" Ball - 1." 1/" Amana FB-RFB10 1/ SP 1/3000 CCW.0" Skel Ball - - FB-RFB158 1/ PSC 1/350 CCW." 3.3" Sleeve /50 - FB-RFB19-1 1/ SP 1/350 CCW 7.0" 3.3" Sleeve - - Armstrong Mid eff. Res., D99-5, , R015859, 0001, Hi eff. Res., , D988-5, R0157, , Fasco , , CUIC Mid eff., Res., , , Fasco , A19 3 FB-RFB50 1/30 08/ SP 1/3000 CCW 5.75" 3.3" Ball - - Rooftop, , FB-RFB1 1/ SP 1/3000 CW 5.75" 3.3" Sleeve - - NEW! JA1N111, FB-RFB5 1/ SP 1/3000 CW 5.8" 3.3" Sleeve - - FB-RFB57-1 1/ SP 1/300 CW 5.8" 3.3" Ball - - FB-RFB03 1/0 08/ SP 1/3000 CCW 8.5" 3.3" Ball - - *Notes: 1 - Comes with gasket(s) Air Ease Mid eff. Ultra 80, Res Air Ease High eff. Ultra 90, 90, Res., G-00, 00-00, , , , Magic Chef, Air Ease, Olsen Rooftop, Comm., , 0388B Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 15

16 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Bradford White FB-RFB19 1/ SP 1/3300 CCW.87" 3.3" Sleeve - - Carrier (cont. next page...) NEW! Fasco A19, , AO Smith 958 Part # HP Volts Amps Type RPM Rot. Body FrameBearing Cap Shaft Comments Fig FB-RFB1-1 1/ SP 1/3000 CCW.3" Skel Ball - - FM-RFM580 1/ SP 1/3000 CCW 3.5" 3.3" Sleeve - 1.9" 5/1" FM-RFM - 1/0 115/30./1.1 SP 1/3000 CW.5" 3.3" Ball -.3" 1/" FM-RFM5-1/0 115/30.1/1.1 SP 1/3000 CCW.5" 3.3" Ball -.3" 1/" UE-33-1/0 115/30.71/.38 PSC 1/1550 Rev.." 3.3" Ball 7.5/370." 1/" FM-RFM80-1/1 115/30 1.0/0.5 PSC 1/350 Rev. 7.0" 3.3" Ball 7.5/370 1." 1/" FM-RFM3-1/1 30/0./. SP 1/3000 CCW." 3.3" Ball -.3" 1/" *Notes: 1 - Comes with two () wiring harnesses - Comes with 5/1" shaft adapter & Built-in centrifugal switch Bryant, Payne Mid Eff., Res. HC1ZE117-13, , , 58SSE08Q-BC Series 130 Blw. Whl. - -A8 Hi Eff.Res. Carrier HC80001, HC7VE1, V579, V580, UE580, JA1P053N, Bryant P Comm. Magnetek 571, Carrier HCAU700, UE571 Blw. Whl. - -A855 Comm. Magnetek 570,UE570, Fedders S Blw. Whl. - -A855 Comm. Magnetek 33, FM-RFM33 Comm. Rooftop, HC80001B, York , 701 Blw. Whl. - -A80(x1") -A85(x") Comm. Magnetek, York, U0 Blw. Whl. - -A Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

17 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Carrier(cont. from previous page...) Part # HP Volts Amps Type RPM Rot. Body FrameBearing Cap Shaft Comments Fig FM-RFM53-1 1/1 30/0 1./. SP 1/3000 CCW." 3.3" Ball -.3" 1/" FM-RFM3-1/1 08/ PSC 1/350 CW 5.0" 3.3" Ball Inc.8" 5/1" FM-RFM - 1/ PSC 1/350 CW.7" 3.3" Ball Inc 3.3" 5/1" Consolidated Industries Clare(cont. next page...) FB-RFB10 1/ SP 1/300 CCW 5." 3.3" Sleeve - - FB-RFB5 1/ SP 1/3000 CCW.9" 3.3" Sleeve - - FM-RFM11 1/ SP 1/3100 CCW 3." 3.3" Sleeve - 1.5" 5/1" Comm. Magnetek 53 Blw. Whl. - -A855 1 HC30GB3, JF1H09N, 8TJE 90/10/150 Comm. Roof Top Blw. Whl. - -A80(x1") -A85(x") HC30GB0, 8TJE 90/10/150 Comm. Roof Top Blw. Whl. - -A80(x1") -A85(x") Part # CFM Volts Amps Type RPM Rot. Body FrameBearing Cap Shaft Comments Fig FB-RFB SP 1/300 CCW 5.98" 3.3" Sleeve - - NEW! JAIN107, 90950, FB-RFB SP 1/300 CCW 5.98" 3.3" Sleeve - - NEW! JAIN118, 30590, FB-RFB SP 1/3300 CCW.0" 3.3" Sleeve - - NEW! UE JA1P08, FB-RFB SP 1/3300 CCW.33" 3.3" Sleeve - - NEW! UE JA1P090, 0150 Consolidated CHU 5-3, 73-3 High Eff. Res: 100, 0950 Fasco , JAIN107NS High Eff Universal Fit, Res: Clare V5 M053, HEG & HEHB 80A Series Residential: Clare V15, Internal Fan, M05, *Notes: 1 - Comes with 5/1" shaft adapter & Built-in centrifugal switch - The rear magnetic centrifugal switch found on most replacements has been built into these Rotom models Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 17

18 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Clare(cont. from previous page...) FB-RFB130 1/ PSC 1/350 CCW 5.0" 3.3" Sleeve /370 - Consolidated CHU 90-3, 108-5, 1-5 High Eff. Res: 101, Fasco High Eff. Res: Clare V17, FM-RFM1 1/ SP 1/3100 CCW." 3.3" Sleeve 1.3" 5/1" M0 Mid Eff. MEG Series, Res: FB-RFB17 1/ SP 1/3000 CCW.9" 3.3" Sleeve - - Clare V17, Fasco Coleman FB-RFB15 1/ SP 1/3000 CCW 5." 3.3" Sleeve - - FB-RFB391 1/ SP 1/300 CCW.0" 3.3" Sleeve - - Dundas Foundry Roof Top Com: Evcon 70-31, Dornback High Eff. G90 Res: 90391P, UE95, Fasco , FB-RFB500 1/ SP 1/80 CCW 5.5" 3.3" Sleeve - - Greenhouse Blower, Com: Fasco 5075-D500, Dundas Foundry Cooler Blower Fan, UE99 Ducane FB-RFB93 1/ SP 1/800 CCW." 3.3" Sleeve - - FB-RFB8 1/ SP 1/3000 CCW 7.3" 3.3" Sleeve - - FB-RFB50 1/ PSC 1/350 CCW.5" 3.3 Sleeve /370 - Ducane, Lennox Air-Flo High Eff. (NEW) MPG50B3, 75B3, B, 100B, 100B5, 15B5 Res: , 0800 Ducane, Lennox Air-Flo High Eff. (New) CMPB50U - 50U3, 75U - 75U3 Res: 08001, 0800, R0301,9L1-01, 9L1, Ducane, Lennox Air-Flo High Efficiency (Old) CMPA50UA, 75UA, 100UA, 15UA Res: , Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

19 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Goodman FB-RFB1-1 1/50 08/ SP 1/3000 CW 8.5" 3.3" Sleeve - - FB-RFB10 1/ SP 1/300 CCW 5." 3.3" Sleeve - - FB-RFB185-1/ SP 1/3000 CW 5.8" Skel Sleeve - - Grimsby Roof Top Com: Goodman B , Fasco Goodman-Janitrol GNPS, High Eff. Res: B , JAIN107NS Goodman-Janitrol GNP Mid Eff. Res: B FB-RFB590 1/ SP 3000 CW 5." Skel Ball - - B , FB-RFB595 1/ SP 3000 CW 5.89" Skel Ball - - B FB-RFB7 1/ SP 3000 CW 5." Skel Ball M0000P FB-RFB501 1/ SP 3000 CW 5.57" Skel Ball FB-RFB111 1/ SP 1/3000 CCW.0" 3.3" Sleeve - - SC-OLV-1- Mid Efficiency Res: SBC375, CPL113 8 General Replacement FM-RFM -3 1/35 115/30 1.3/.5 SP 1/3000 CCW 5.8" 3.3" Ball - 3.9" 5/1" FM-RFM10-3 1/35 115/30 1./0. SP 1/3000 CW 5." 3.3" Ball - 3.9" 5/1" *Notes: 1 - Built-in end switch - Comes with gasket 3 - Feature an internal fan, stainless steel shaft and built-in centrifugal switch Franklin 80137, Fasco D0, D08 EJ Walsh , Fedders FM-RFM10 - Fasco D10, D09, D1, 1/10 115/30 1.5/0.7 PSC 1/3000 Rev. 7.1" 3.3" Ball 7.5/ " 1/" 10 Reznor UE-37-1/ PSC 1/3000 Rev..5" 3.3" Ball / " 1/" Magnetek UE-371-1/8 08/ PSC 1/3000 Rev..5" 3.3" Ball / " 1/" Magnetek Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 19

20 OEM Replacement Motors Coupling Included Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 G.S.W. FB-RFB17-1 1/ SP 1/300 CCW 1.5" 3.3" Sleeve - - John Woods Water Heater GSW 317, Fasco FB-RFB17 1/ SP 1/300 CCW 1.5" 3.3" Sleeve - - Heil Quaker fb-rfb7 1/ SP 1/3150 CCW 5.71" 3.3" Sleeve - - A0, 107, X ICP (cont. next page...) John Woods Water Heater GSW 317, Fasco FM-RFM50-1/00 08/ SP 1/3000 CCW.9" Skel. Sleeve - 0.8" 1/" FB-RFB11 1/ SP 1/800 CCW.0" 3.3" Ball - - FB-RFB571 1/ PSC /3000 CW.35" 3.3" Ball Inc - FB-RFB8 1/50 08/30 0. SP 1/3000 CW 5.8" 3.3" Ball - - Keeprite Roof Top RGA Series, Com: 5015K, 50015K, Blw. Whl (") 93-10(") Residential: , NEW! , , A19, , Commercial: 1058, FB-RFB105 1/ SP 1/300 CW 5.7" 3.3" Sleeve - - FB-RFB8-3 1/ SP 1/3000 CCW 5.5" 3.3" Sleeve - - Keeprite Roof Top RGA, RGAA, Com: Keeprite 10501, JA1M109NS, Heil Quaker, Intercity, HQ10501, Whirlpool, A151, A.O. 77 Keeprite CUGE, CPGE, CULE, MGH Mid Eff. Res: *Notes: 1 - Includes Coupling. - Comes with 5/1" shaft adapter. Built-in centrifugal switch. 3 - Comes with two () gaskets, high temp. silicone & instructions 0 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

21 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Coupling Included Fig. 9 Fig. 10 Fig. 11 ICP (cont. from previous page...)(cont. next page...) FB-RFB /0 08/ PSC /3350 /900 CW 8.70" 3.3" Sleeve 3/370 - Keeprite PGB, PGA, PGD, GPD, RGMA Com: Keeprite 10975, Ton 1 FB-RFB33 1/ SP 1/3000 CW.00" Skel Ball , FB-RFB833 1/ SP 1/3000 CCW.50" Skel Ball M3-R09 1/ SP 1/1550 CW 3.0".1" Sleeve -." 1/" M3-R1 1/ SP 1/1550 CCW 3.0".1" Sleeve -." 1/" FB-RFB 1/ SP 1/300 CCW 7.0" 3.3" Sleeve - - B-RFB350 1/ PSC 1/350 CW 7.10" 3.3" Ball 5/370 - FB-RFB13 1/ SP 1/3000 CCW.0" 3.3" Sleeve - - FB-RFB15-1/ PSC 1/350 CW 5.3" 3.3" Ball /50 - FB-RFB11 1/ PSC 1/350 CW 7.75" 3.3" Sleeve /50 - FB-RFB330 1/ SP 3000 CCW 5.5" Skel Ball - - FB-RFB170 1/ SP 1/800 CW 5.75" 3.3" Ball - - Intercity Condo & Apartment Exhaust Fan Motor UE009 Intercity Condo & Apartment Exhaust Fan Motor UE010 Keeprite, , B0, CRC Keeprite CGJ, CGK High Eff. 50, 75, 100, 15 Res: Hardware Connection Kit - FB-RFB350-1 Keeprite, Heil, Comfortmaker NTC Mid Eff. Res: 10103, , , Airco, Tempstar Keeprite, Heil, Comfortmaker NTGM High Effi. Res: 10099, , , 10110, 10111, 1180, Airco, Tempstar Res: , , Intercity , 10081P A , , Res: , *Notes: 1 - Comes with gaskets - Vent Restrictor Orifice Plates: ICP 50 & 75, ICP 100, ICP 15, Comes with coupling, pins, O-rings and gaskets Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 1

22 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 ICP (cont. from previous page...) FM-RFM3-1 1/1 08/ PSC 1/350 CW 5.0" 3.3" Ball /370.8" 5/1" FM-RFM -1 1/ PSC 1/350 CW.7" 3.3" Ball / " 5/1" FM-RFM9-1/15 08/ SP 1/3000 CCW." 3.3" Ball - - FB-RFB9 1/1 08/ SP 1/3000 CCW 10.0" 3.3" Ball - - Lennox(cont. next page...) FB-RFB135 1/ SP 1/3000 CW 5.5" 3.3" Sleeve - - Air-Flo Unit Heater Com.: Lennox 19J0, Fasco , FB-RFB390 1/ SP 1/3000 CCW 5.5" 3.3" Sleeve - - Res: 88J3901, 701-9, A19 5 FB-RFB95 1/ SP 1/3000 CW 5.3" Skel. Ball - - NEW! W95, 31L5501 FB-RFB3 1/ SP 1/3000 CW 5.8" 3.3" Sleeve - - G Mid Eff. 3K1 FB-RFB98 1/ SP 1/3000 CW 5.8" 3.3" Sleeve - - NEW! G Mid Eff. 11K98 Kit FB-RFB99 1/ SP 1/3000 CW 5.8" 3.3" Sleeve - - NEW! G Mid Eff. 11K99 Kit FB-RFB1-3 1/ SP 1/3000 CW 5.8" 3.3" Sleeve HC30GB3, JF1H09N, 8TJE 90/10/150 Com. Roof Top, ICP , JF1H09N Blw. Whl. - -A80(x1") -A85(x") HC30GB0, 8TJE 90/10/150 Com. Roof Top ICP Blw. Whl. - -A80(x1") -A85(x") Keeprite Roof Top, Blw. Whl. - -A810 Keeprite, Heil, Comfortmaker RGB Series Roof Top Com: Res: K101, Fasco FB-RFB80 1/ SP 1/3000 CW 5.83" Skel Ball K801, 85L *Notes: 1 - The rear magnetic centrifugal switch found on most replacements has been built into these Rotom models - Built-in centrifugal switch 3 - Features air tube fitting Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

23 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Fig. 10 Lennox (cont. from previous page...) FM-RFM1198 1/ SP 1/300 CCW 3.0" 3.3" Sleeve - ¼" 5/1" FB-RFB790 1/ SP 1/3000 CCW Skel Ball - - FB-RFB810 1/ SP 1/3000 CCW Skel Ball - - Roof Top Com: Lennox 5J101, Fasco Res: 0M7901, , A07 Com: 0M8101, , A08 FM-RFM890 1/5 08/ SP 1/300 CCW 3.9" 3.3" Ball -.3" 5/1" GCS3 Roof Top Com: Lennox 98G8901 Fasco BLW. WHL - -A877 FB-RFB385 1/ PSC /300 /800 CCW 3.3" Ball 7.5/370 - Res: 38M5001, 70-51, A09 FB-RFB57-1 1/ SP 1/300 CW 5.8" 3.3" Ball - - FB-RFB550 1/ SP 1/3000 CCW 3.3" Ball - - FB-RFB811 1/ SP 1/300 CCW 3.3" Ball - - FB-RFB101-1/1 08/ PSC 1/300 CCW 8.5" 3.3" Ball 3/370 - FB-RFB701 1/10 08/30 0. PSC 1/300 CCW.75" 3.3" Ball /370 - FB-RFB30 1/ /.33 PSC 1/300 CW 3.3" Sleeve - G High Eff. Series Res: 8K1, Fasco Com: 5M5501, , A17 Res: 81M101, , A11 GCS Roof Top Com: Lennox 3G8101, 13537, 07, 8G01, Fasco , Roof Top Com: Lennox 98G8701 Com: 9M301, , , , 97J *Notes: 1 - Comes with gasket set - Comes with gasket. Built-in centrifugal switch Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 3

24 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Modine FB-RFB598 1/15 00/30.95/1.1 SP 1/330 CCW 3.3" Sleeve - - 5H Newmac R7-RB33-1 1/ SP 1/300 CW." 3.3" Sleeve - - Nordyne, Frigidaire, Miller Nutech Oil & Wood Furnace FB-RFB903-1/ SP 1/3000 CCW 5." 3.3" Sleeve - - FB-RFB90 1/ PSC 1/350 CCW 5.5" 3.3" Sleeve /370 - G5RA, GRA, G3 Mid Eff. Res.: , UE95 G5RC, GRC, G1, G High Eff Res.: Heat Recovery Blower O1-R5 1/ SP 3/1550 CW.0" 3.3" Sleeve -.3" 5/1".1" Electrohome , 5 15, Nutech Lifebreath 30 M-R55 1/ PSC 1/1550 CCW 3.0" 5.0" Sleeve 5/370.5" 3/8"." M-R3 1/ PSC 1/1550 CCW 3." 5.0" Ball 3/370.7" 3/8"." Heat Recovery Blower AO81B355, Fasco Heat Recovery Blower Nubreath 3-0, GE5KCP98G850BS, Fasco *Notes: 1 - Features a built-in variable speed control - Comes with gasket Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

25 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Olsen FB-RFB / SP 1/300 CW." 3.3" Ball - - FB-RFB00-1 1/ SP 1/300 CCW." 3.3" Ball - - Airco High Eff HCS- 0, 75, 81, 90 Left Hand Discharge Res: 1810 HCS- High Eff. 0, 75, 81, 90 Right Hand Discharge Residential: 008, FB-RFB10 1/ SP 1/300 CCW 5." 3.3" Sleeve - - Consolidated NUP 5-3, 7-3 High Eff. Res: 100, JAIN107NS 3 FB-RFB11-1/ SP 1/3000 CCW.0" 3.3" Sleeve - - Airco HMS/HMS-T Mid Eff. Res: 98, 987, 83 FB-RFB7 1/ SP 3000 CW 5.9 Skel Ball 97 5 FB-RFB111 1/ SP 1/3000 CCW.0" 3.3" Sleeve - - Residential: SBC375, CPL113 FB-RFB03 1/0 08/ SP 1/3000 CCW 8.5" 3.3" Ball - - Com. Rooftop 355A 7 FB-RFB130 1/ PSC 1/350 CCW 5.0" 3.3" Sleeve /370 - Reznor Consolidated NUP N1, 1, 0, 90-3, 108-5, 1-5 H.E. Res: FM-RFM78-3 1/10 115/30 1.3/0.7 PSC 1/300 Rev..1" 3.3" Ball / " 5/1" Commercial: Reznor 38 (115V), 3 (08/30), FM-RFM7, FM-RFM8 BLW. WHL - -A875 9 *Notes: 1 - Comes with three (3) brackets, fastening hardware, drain tubing & instructions. - Includes pressure switch, two () gaskets, mounting plate, silicone tubing & instructions 3 - Double blower wheel 3.15" 5/1" Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 5

26 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Rheem-Ruud FB-RFB139-1 Hot Water Heater SP1108, 1/ SP 1/970 CCW 11.0" 3.3" Sleeve - - Fasco FB-RFB1 - RGDE Mid Eff. Res: Fasco 1/ SP 1/3000 CW 5.3" 3.3" Sleeve , A079 FB-RFB090-1/ SP 1/3000 CCW 5.0" 3.3" Sleeve - - RGDE Mid Eff. Res: , Fasco , Magnetek JA1M10 3 FB-RFB107-1/0 08/ PSC /3350 /900 CW 8.70" 3.3" Sleeve 3/370 - Roof Top, PGB, PGA, PGD, GPD, RGMA Com: Reem- Rudd , , Ton FB-RFB / SP 1/3000 CCW 5.5" 3.3" Sleeve - - FB-RFB1 1/5 08/30 0. SP 1/300 CCW 3.3" Sleeve - - FB-RFB1 1/ PSC 1/350 CCW.0" 3.3" Sleeve /370 - Rheem-Ruud , UE JA1M11N Com: , , A1 Weather King RGT High Eff. Res: , , , , Fasco FB-RFB13 1/ PSC 1/350 CCW.5" 3.3" Sleeve /50 - Weather King RGT High Eff. Res: , Fasco FB-RFB0 1/ PSC /300 /00 CW 3.3" Sleeve - Residential: , , A FB-RFB1-1/ SP 1/300 CCW.3" Skel Ball - - Weather King RGP Mid Eff. Conquest 800 Res: Fasco , *Notes: 1 - Includes coupling, adapter horn, plug, screws & tubing - Comes wiuth gasket 3 - Includes two () gaskets & 90 brass fitting - Comes with gasket mounted Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

27 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Fig. 9 Fig. 10 Trane(cont. next page...) FB-RFB15 1/ SP 1/3000 CCW 5.89" 3.3" Sleeve - - NEW! TUD0, 0, 80, 100 Mid FB-RFB13 1/ SP 1/3000 CCW 5." 3.3" Sleeve - - Eff., Res: BLW0073, Fasco Rooftop Flue Exhaust FB-RFB380 1/0 08/ PSC 1/800 CCW 8.10" 3.3" Ball /370 - Blower Res: Trane X , FB-RFB5-3 1/35 115/30.95/.9 SP 1/3000 CW 8." 3.3" Ball - - Com: FB-RFB150 1/30 08/ SP 1/3000 CW 5.5" 3.3" Ball - - NEW! A150, FB-RFB73-1 1/30 115/30.8/. SP 1/3000 CW 5.3" 3.3" Ball - - Rooftop Com: Trane 38005, Amana-Tappan, Janitrol 9-3, UE77 FB-RFB787 1/ SP 3000 CW.00" Skel Ball - - D330787P01, UE-95 1/ PSC 3/1100 CW.0" 5" Sleeve Inc. 8.5" 1/" UE-908 1/ PSC 3/1100 Rev. 3.5" 5" Sleeve Inc. 9.5" 1/" UE-1 1/ PSC 3/1075 CW 3.5" 5" Sleeve Inc. 8.5" 1/" 9" FB-RFB130 1/ PSC 1/350 CCW 5.0" 3.3" Sleeve /370 - MOT 1878, MOT 1875, X , EM K8HXBYH-95 MOT 1875, X , EM K8HXBHZ955 MOT 187, CX , UE DE3E15 TUCG 0, 80, 100 High Eff. Res: BW000517, UE *Notes: 1 - Comes with round and square stud brackets Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 7

28 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Trane (cont. from previous page...) MOT 1877, X , UE-953 1/ PSC 3/1100 CW 3.5" 5" Sleeve Inc. 10.5" 1/" 10.5" EM K8HXBJA-95 1 UE-95 1/ PSC 3/1500 CW.0" 5" Sleeve Inc. 9" 1/" 7.5" UE-955 1/ PSC 3/1500 CW.0" 5" Sleeve Inc. 10.5" 1/" 10.5" UE- 1/ PSC 3/175 CW.0" 5" Sleeve Inc. 8" 1/" 8" MOT 1978, MOT 81, X , EM K8HXCKT-119 MOT 1979, MOT 8, X , EM K8HXCKS-118 MOT 89, X , UE DEG101 1 Vanee R3-R38 1/15 110/ PSC /1550 CCW.1" 3.3" Sleeve / " 3/8" Venmar Heat Recovery Motor M1703, Fasco , Fasco , Kit R-R 1/ PSC 3/10 CW.13" 3.3" Sleeve 7.5/ " 3/8" 3.5" 107, 109, 1109 R-R38 1/ PSC /100 CW.31" 3.3" Sleeve / " 5/1" 01038, Fasco , Fasco , Kit R3-R3 1/ PSC 3/130 CW " Sleeve 7.5/370.97" 3/8" 3" 10, 1151 R-R 1/ PSC 3/190 CW.93" 3.3" Sleeve 7.5/370.0" 3/8" 009, Fasco Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

29 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 Williamson Furnace FB-RFB58 1/ SP 1/3000 CCW 5.71" 3.3" Sleeve - - FB-RFB118 1/ SP 1/3000 CCW 5.93" 3.3" Sleeve - - York(cont. next page...) NEW! A080, , 0-58, S88-81 NEW! A118, , , X FB-RFB51-1 1/ SP 1/3000 CW 5.3" 3.3" Ball - - FB-RFB3 1/0 08/ SP 1/3000 CW.3" 3.3" Ball - - FB-RFB1-1/0 08/ SP 1/3000 CCW 8.0" 3.3" Sleeve - - P9UGD, PHUGD Standard Eff. Res: , C000, Luxaire Roof Top, D8SA, D9SA Com: , UE771, Fasco A03, UE, Roof Top DCG Unit Com: York , 018, 705, FB-RFB1-3 1/ PSC 1/300 Rev. 9.5" 3.3" Ball /370 - FB-RFB -3 1/ PSC 1/300 Rev. 10.5" 3.3" Ball /370 - FM-RFM1-3 1/ SP 1/300 CW 5.7" 3.3" Ball -.5" 1/" FB-RFB9-1/0 08/30 /0 0.3 SP 1/3000 CCW 8." 3.3" Sleeve - - D1, D, 7.5 Ton Roof Top Unit Com: , 00, 713, Fasco BLW. WHL - -A80("x1"x1/") D1, D Roof Top Unit Com: , 00, 713, Fasco BLW. WHL - -A85("x"x5/1") Commercial: B, 019B Roof Top DCG Com: York , -900, , *Notes: 1 - Comes with gasket - Comes with gasket. Built-in centrifugal switch 3 - Built-in centrifugal switch Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 9

30 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. Fig. 7 Fig. 8 York(cont. from previous page...)(cont. next page...) Com: York , FB-RFB , 007, -39, 1/35 115/30.95/.9 SP 1/3000 CW 8." 3.3" Ball , UE770, 08, 51, 1 Fasco A03 FB-RFB3-1/ SP 1/300 CW 8.5" 3.3" Ball - - D1, D Roof Top Unit Com: , 019B, 00, 713, Fasco York Furnace P-HUA01 FB-RFB15-3 Mid Eff. Blower N0000 1/ SP 1/3000 CCW.0" 3.3" Sleeve - - Res: York , 3 Fasco , Luxaire FB-RFB15-1/ PSC 1/350 CCW." 3.3" Sleeve /370 - York Furnace P3-URB High Eff. Blower Res: York , Coleman 90391P, Fasco , A15, Luxaire York P3UR A, B, C, D High Eff. Res: , FB-RFB137 1/ PSC 1/350 CCW.0" 3.3" Sleeve / , Fasco 70-5, Luxaire D1, D Roof Top Unit 3.5 To 5 FB-RFB5-5 Ton Com: , 018, 1/1 30/0 1./0. SP 1/3000 CW " Ball , 713, Fasco BLW. WHL - -A80("x1"x1/") FB-RFB55-5 1/1 30/0 1./. SP 1/3000 CW " Ball - - York D3CG07N105-5D Roof Top Ton Com: , 018, 00, Fasco BLW. WHL--A85("x1"x5/1") 7 York D1, D, D3 Roof Top Unit FM-RFM3-5 Magnetek 0, Fasco D1171, 1/1 30/0./. SP 1/3000 CCW." 3.3" Ball -.3" 1/" U0 8 BLW. WHL - -A855 *Notes: 1 - Comes with round & square mounting brackets and mounting hardware. Built-in centrifugal switch - Built-in centrifugal switch 3 - Comes with gasket mounted - Comes with gaskets 5 - Includes -A8 & -A87 blower wheels. Built in centrifugal switch. 30 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

31 OEM Replacement Motors Fig. 1 Fig. Fig. 3 Fig. Fig. 5 Fig. York(cont. from previous page...) FM-RFM53-1 1/1 30/0 1./. SP 1/3000 CW." 3.3" Ball -.3" 1/" FB-RFB187-1/ PSC 1/300 CW.8" 3.3" Ball /370 3/8" 8 ¾" FM-RFM / PSC 1/300 CW.8" 3.3" Ball /370 3/8" 8 ¾" FM-RFM0-1/ PSC 1/300 Rev..9" 3.3" Ball /370 ½" ¼" FM-RFM30-1/ PSC 1/300 Rev..9" 3.3" Ball /370 ½" ¼" FB-RFB31-1 1/ PSC 1/300 Rev. 9." 3.3" Ball /370 - FB-RFB3-1 1/ PSC 1/300 Rev. 10.5" 3.3" Ball /370 - *Notes: 1 - Built-in centrifugal switch - Includes -A8 & -A87 blower wheels. Built in centrifugal switch. 3 - DOES NOT include -A8 & -A87 blower wheels. Built in centrifugal switch. - Comes with 5/1" shaft adapter. Built-in centrifugal switch York D1, D, D3 Roof Top Unit Magnetek 53, Fasco D117 BLW. WHL - -A850 York 10 Ton Roof Top Blower DICG10N155A Commercial: , 5005, 570, D1187 York 10 Ton Roof Top Blower DICG10N155A Commercial: , 5005, 570, D1187 York D1, D Roof Top Unit , 017, 700, 709, 713, Fasco D1171, YVFM50 York D1, D Roof Top Unit , 71 York D1, D 5 Ton Roof Top Unit Com: York , 018 BLW. WHL - -A80("x1"x1/") York D1, D 7.5 Ton Roof Top Unit Com: York , 018 BLW. WHL - -A85("x"x5/1") LEGAL NOTICE Rotom is a registered trademark of Alltemp Products Company Limited (Alltemp) It is important to note that Alltemp is not affiliated with any of the original equipment manufacturers or their brands which may be referred to herein. All brand names or trademarks used herein are the property of their respective owners and all original equipment manufacturers names, numbers, symbols and descriptions are for cross reference purposes only. It is not implied that any part referred to herein is the product of any original equipment manufacturer, nor any of its associated brands. TRADEMARK DISCLAIMER Product names, logos, brands, and other trademarks featured within are the property of their respective trademark holders. These trademark holders are not affiliated with Alltemp, our products or our website. No association between Alltemp and any trademark holder is expressed or implied. Names, numbers, symbols and descriptions are for cross reference purposes only. Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

32 Pulleys & Bearings Aluminium Pulleys 7-0 Blower Pulleys Part # Bore Diameter 7-50* 5" 7-0 " " /" 8" " " 7-1 1" * 5" pulley is solid Blower Pulleys - Continued Part # Bore Diameter 7-80 " " " " 9" " " 7-35 Variable Speed Pulleys Part # Bore Diameter /" /" 1/" /" 7-00 " /" /" 5/8" /" " Cast aluminum pulley mfg'd to OEM specs Bearings Ball Bearings Bearings complete with collar. Part # Bore OD Replaces LRCR 3/" 1 13/1" () Bearings & () Collars " ¼" RCR Sleeve Bearing Packs Kits include bearings & rubber sleeves. Part # Bore OD Type Replaces /" 1 5/3" Delhi Oil " ½" Delhi /8" 1 7/8" Lau Delhi 1 13/1" /" Lau & Lennox /8" Sealed Torin 7-1- Delhi " ½" Lau & Lennox Torin Bearings & Sleeves Part # Bore Type 7-13-R 3/" Rubber sleeve 7-1-R 1" Rubber sleeve 7-13-B 3/" Sealed bearing 7-1-B 1" Sealed bearing 7-03-B 3/" Oil bearing 7-0-B 1" Oil bearing 7-13-R Oil Type Sealed Type 7-13-B 7-0-B Thrust Collar Packs Part # Description 7-1 () 5/8" collars & washers () 3/" collars & washers. 7-1 () 1" collars & washers Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

33 Shafts & Mounting Brackets Shafts Shafts Sized to bearing manufacturers specifications. Slabbed on pulley end. Rust protected. Individually wrapped. Protective end caps. Part number and size listed on every shaft Shafts Part # Diameter Length Coss Reference " Lennox, /8" Lennox /" C, " 8-5-5C, /1" G9, G1-9, , WW15X3, 1001, 10013, " /" /8" 8-5-0C, G10, G110, , " 8-5-7C, 8-5-1C, /8" G1, " M90-5, RS " " 8-5-3C " " G15-7, 10015, , , " 5" 8-5-5C & 55C, M90-57, G15, , 55, 5, " P-S-09, M90-70, 10018, 10005, 1005 Mounting Brackets 9-A817 Torsion Flex Bracket 5.0" and 5.5" Dia. 9" & 10" Bolt Circles 9-A8550 5" Diameter 9-A " Diameter 9" & 10" Bolt Circles 5.5" Diameter for 1/ HP and above 9-A855 9" Bolt Circle 9-A " Bolt Circle HEAVY DUTY Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 33

34 Air Duct Booster Designed to be installed at any angle in the branch duct of under-ventilated rooms to increase either hot or cool air flow supply. One year limited warranty. Poor Air Flow From Main Supply Control Options Manual Control 115V Source - continuous operation. 115V Switch - manual ON/ OFF ctrl. Enhanced / Air Flow To Problem Area Duct Boosters In-Line Air Duct Booster Fans Automatic Control Wire to furnace fan. Wire to fan switch. Wire to a sail switch. Wire to a pressure switch. Wire to thermostat. Standard Air Duct Boosters Part # Description Max Boosted CFM Free Air CFM Watts Amps dba Blade Housing Length T9-DB8 " - 8" Universal Round Polycarbonate " 11" T9-DB-CR " Rnd Double Crimp Polycarbonate 8" T9-DB " Round Polycarbonate " T9-DB5 5" Round Polycarbonate " T9-DB " Round Polycarbonate " T9-DB8 8" Round Polycarbonate 8" T9-DB10 10" Round Aluminium 8" T9-DB1R 1" Round Aluminium 8" Two Speed Air Duct Boosters Part # Description Max Boosted CFM Free Air CFM Watts Amps dba Blade T9-DB- " Round Speed 00/300 10/ /5 Polycarbonate T9-DB8-8" Round Speed 500/00 10/ /55 Polycarbonate T9-DB10-10" Round Speed 50/ / /59 Aluminium T9-DB8 T9-DB T9-DB5- -Pole Duct Boosters Designed for larger ducts requiring commercial grade power and performance. Part # Description Max Boosted Free Air Watts Amps CFM CFM dba Blade T9-DB1 1" Round Aluminium T9-DB1 1" Round Aluminium T9-DB1 1" Round Aluminium Duct Thermostat Plug-In Duct Stat The T9-DS5110 duct stat simplifies installation of in-line duct booster fans by eliminating electrical connections at the furnace. Plug-In Switch - Thermostatically Controlled Economical and reliable automatic on/off control for in-line duct booster fans. Mounts on duct or wall to control ambient room temperature. Adjustable temperature range: 5 F (7 C) to 110 F (3 C) and differential. ' Grounded cord. Year round use, ON/ OFF, AUTO heating and AUTO cooling. Controls various devices, including alarms, heat lamps, lights, louvers, etc. Part # Description Volts Dimensions Weight 5 Amp maximum load 5.50" 3.5" 1.5 T9-DS (replaceable 5A fuse)..5" lbs. T9-DS5110 illustrated -Pole Duct Booster 3 Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End)

35 In-line Duct Boosters In-Line Air Duct Booster Fans Features High Volume & Pressure Installs In Any Position Ball Bearings Are Permanently Sealed & Lubricated Backwards Inclined Blades Vibration Absorbing Material Class B TP Auto Reset UB Protected / Flame Retardant - Thermal Plastic Resin 10 F(0 C) Maximum Air Stream Tempurature Applications Ventilation Exhaust In-Line Boosting Radon Mitigation Dryer Vent Boosting Duct Muffler Part # Amps Watts Duct Dia. Volts Hz CFM T9-TF " T9-TF " T9-TF " Serious Air Power With Quiet Operation 5 YEAR LIMITED Warranty Accessories Speed Control Power Cord Auto Switch Duct Mufflers Part # Diameter Length T9-DM105 5" " T9-DM10 " " T9-DM108 8" " T9-DM110 10" 3" T9-DM11 1" 3" Cat # ROT ROTOM is a registered trade marks of ALLTEMP PRODUCTS COMPANY LIMITED. ALLTEMP has made an effort to illustrate with photos, outline drawings and/or descriptions, the products in this catalogue. These are for the sole purpose of identification. We do not express or imply that products conform exactly to the descriptions, drawings and/or photos. All reasonable effort has been made to accurately determine a suitable product. However, all users are solely responsible to evaluate and determine for themselves the suitability of the product purchased for the use intended. All information, data and dimension tables in this catalogue have been carefully compiled and thoroughly checked. However, no responsibility for possible errors or omissions can be assumed. The company reserves the right to change specifications and other information included in this catalogue without notice. The vendor s responsibility shall be limited only to its written warranty and the vendor shall not be responsible for any loss, cost or damage whatsoever from the use of this product by you or your customers. Motors Are Sleeve Bearing Unless Indicated - Rotation Determined Opposite Shaft End (Double Shaft Determined By Lead End) 35

DRAFT INDUCER CROSS REFERENCE GUIDE FOR FURNACES AND WATER HEATERS THE REPLACEMENT MOTOR AND BLOWER SPECIALISTS

DRAFT INDUCER CROSS REFERENCE GUIDE FOR FURNACES AND WATER HEATERS THE REPLACEMENT MOTOR AND BLOWER SPECIALISTS DRAFT INDUCER CROSS REFERENCE GUIDE FOR FURNACES AND WATER HEATERS THE REPLACEMENT MOTOR AND BLOWER SPECIALISTS ABOUT DRAFT INDUCED BLOWERS Many of the new energy-efficient gas furnaces use induced draft

More information

Replacements listed may not be an exact duplicate of original motor. HP RPM VOLTS FRAME BRGS. CAT. MODEL LIST MULT. F.L. APPROX.

Replacements listed may not be an exact duplicate of original motor. HP RPM VOLTS FRAME BRGS. CAT. MODEL LIST MULT. F.L. APPROX. OEM: Admiral-Emerson Single Phase, PSC Replaces Fasco No. D853 3 lug mounting 1/3 1300/3 230 48Y BALL X204 48A17O126 $162 F1 2.5 10 4 3/8 2 1/8 x 1/2 x 4 7/8 16 OEM: Amana/Rheem/Luxaire/Rooftop Package

More information

Replacement Fractional Horsepower Motors

Replacement Fractional Horsepower Motors TOTALINE UNIVERSAL AFTERMARKET MOTORS Replacement Fractional Horsepower Motors for the HVAC/R Industry TRUST TOTALINE ON YOUR TRUCK DIRECT DRIVE BLOWER MOTORS Totaline Direct Drive Blower Motors are three

More information

Replacement Fractional Horsepower Motors for the HVAC/R Industry

Replacement Fractional Horsepower Motors for the HVAC/R Industry Motors Replacement Fractional Horsepower Motors for the HVAC/R Industry MOTORS Table of Contents Motors Page No. HVAC Motors: Azure Digi-Motor, Direct Drive...M-3 Azure Digi-Motor, Condenser Fan...M-3

More information

SOS Multi-Horsepower Outdoor Condenser Fan Motor

SOS Multi-Horsepower Outdoor Condenser Fan Motor SOS Multi-Horsepower Outdoor Condenser Fan Motor Slim Stack # 03458 Wizard fits many 1/3 HP installations that will not accept competitor s motors. Wide range motor that will run at any fan load from 1/6

More information

SELECTING A MOTOR MOTORS

SELECTING A MOTOR MOTORS SELECTING A MOTOR Although selecting a replacement motor isn t a science, there are rules, and rules of thumb, that will provide you with a suitable replacement motor. It should be mentioned that the best

More information

Q4100C Hot Surface Igniter

Q4100C Hot Surface Igniter Q4100C Hot Surface Igniter INSTALLATION INSTRUCTIONS APPLICATION Q4100C Hot Surface Igniters are designed to provide a robust field service replacement igniter in gas fired appliances with 120 VAC silicon

More information

Hot Surface Ignitor Kits

Hot Surface Ignitor Kits 26/09/08 A80-1 Hot Surface Ignitor Kits Hot Surface Ignitor & Flame Sensor Kit Kit includes common replacement items a service technician would need for the job as well as a complete HSI cross reference

More information

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts. BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection

More information

for Refrigeration Applications

for Refrigeration Applications A Regal Brand for Refrigeration Applications Direct Drop-In Replacement Supermarket Case Evaporator Fan Motor Advanced ECM Design Cast Iron 15 Leads Lyall Plug UL/CUL approved E128044 Up to 65% Efficiency

More information

A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 AND IP67 RATING

A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 AND IP67 RATING KRYO FORTRESS RESS MOTORS/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 AND IP67 RATING BUILT TO PROTECT The KRYO FORTRESS motor is an energy-efficient, unit bearing style ECM

More information

KRYO FORTRESS MOTOR/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING

KRYO FORTRESS MOTOR/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING KRYO FORTRESS MOTOR/FAN PACKS A HIGH- ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING motor BUILT TO PROTECT The KRYO FORTRESS motor is an energy-efficient, unit bearing style ECM motor built to withstand

More information

ACME MIAMI. Product Catalog

ACME MIAMI.   Product Catalog ACME www.acmemiami.com Product Catalog Contents Defrost Heaters... 1 Flexible Bend-to-Fit for Coils & Condensate Pans 700 Series and Ball Bearing Motor Kits... 2 & 3 Commercial Refrigeration Motor Kits

More information

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631) Digi-Motor Azure Direct Drive Motor Azure Condenser Fan Motor Azure 3.3" Commercial Refrigeration Evaporator Fan Motor ECM for Commercial Refrigeration Fan/Motor System Made in USA Case Motor IP55 Rated

More information

The Replacement Motor & Fan Specialists

The Replacement Motor & Fan Specialists The Replacement Motor & Fan Specialists Residential Commercial Electric Motors Fans & Blowers Hydronic Pumps Accessories www.soperssupply.com Industrial Soper s Supply Ltd. Proud Distributor of the Following

More information

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION

More information

June 8, Davies Supply Calgary (800) Lethbridge (877) Saskatoon (877) (403) (403) (306)

June 8, Davies Supply Calgary (800) Lethbridge (877) Saskatoon (877) (403) (403) (306) June 8, 2018 Terms & Conditions Prices only available to customers with a current Davies Account that is in good standing Limited quantities, availability may vary by branch Quantity listed may not be

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

July 20, Davies Supply Calgary (800) Lethbridge (877) Saskatoon (877) (403) (403) (306)

July 20, Davies Supply Calgary (800) Lethbridge (877) Saskatoon (877) (403) (403) (306) July 20, 2018 Limited quantities, availability may vary by branch Quantity listed may not be available at time of order Absolutely no rain checks or backorders to manufacturer INDEX WATER TREATMENT, FLUID

More information

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source! Propeller Fans Industrial And Commercial Fans Belt And Direct Drive Your Clean Air Source! MODEL PVL EXHAUST FANS Application Economical fans for use in kitchens, laundries, taverns, bakeries and also

More information

FM1500 SERVICE PARTS

FM1500 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing the parts to be certain that this is the correct parts list. FM00 SERVICE PARTS

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

MLG35 Parts Manual Phase 8

MLG35 Parts Manual Phase 8 MLG35 Parts Manual Phase 8 For Internal Use Only RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Whirlpool Corporation Commercial Laundry Benton Harbor, MI 49022 1-800-662-3587 Part No.

More information

HM-R250 Includes 3 prong plug, built in end switch, threaded shaft end with hub. Part # HP Volts Amps Type RPM Rot. Body Frame Bearing Shaft

HM-R250 Includes 3 prong plug, built in end switch, threaded shaft end with hub. Part # HP Volts Amps Type RPM Rot. Body Frame Bearing Shaft Blowers, Motors & Fan Kits Acorn, Selkirk Acorn Wood Stove 71730867, 2868509042 Selkirk 605850M0 Part # HP Volts Amps Type RPM Rot. Body Frame Bearing Shaft HM-R250 1/70 115 0.65 SP/ TE 2/1500 CCW 3.5"

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

ADG-531HS Hot Surface Ignition

ADG-531HS Hot Surface Ignition ADG-531HS Hot Surface Ignition Parts Manual 1998 American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9010 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com 120997JEV/abe

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

ALG181J6 TAMBOR (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P)

ALG181J6 TAMBOR (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) ALG181J6 TAMBOR ALG181J6 TAMBOR 1 131084710 PANEL LELF SIDE WHITE (S/P) 1 131084701 PANEL LELF SIDE ALMOND (S/P) 2 131168200 SCREW (S/P) 3 131883301 PANEL (S/P) 4 134799902 PANEL REAR (S/P) 5 5303281019

More information

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS *s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended

More information

Installation Guide.

Installation Guide. Installation Guide www.evergreendealer.com www.thedealertoolbox.com When Regal Beloit acquired General Electric s Commercial and HVACR Motors and Capacitors businesses in 2004, it also acquired the rights

More information

Technician's Pricing Guide NORTH RESIDENTIAL. Collier Consulting Group

Technician's Pricing Guide NORTH RESIDENTIAL. Collier Consulting Group Technician's Pricing Guide NORTH RESIDENTIAL Collier Consulting Group Table Of Contents Service Batteries (BT) Bearings and Shafts (BG) Belts (BE) Boiler Repairs (BR) Carbon Monoxide Detection (CT) Carrier

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

THE PREMIUM QUALITY LINE FROM HEAVY DUTY, INDUSTRIAL AND COMMERCIAL AIR CIRCULATORS

THE PREMIUM QUALITY LINE FROM HEAVY DUTY, INDUSTRIAL AND COMMERCIAL AIR CIRCULATORS THE PREMIUM QUALITY LINE FROM HEAVY DUTY, INDUSTRIAL AND COMMERCIAL AIR CIRCULATORS Visit our website at: www.marleymep.com AUTOMOTIVE AIR CIRCULATOR Safety yellow motor, guards, and mounts Hinged guards

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

ES-5050 / ES5050TE Parts Manual

ES-5050 / ES5050TE Parts Manual ES-5050 / ES5050TE Parts Manual Phase 8 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

Dean Pump High Temperature Chemical Process Inline Pumps

Dean Pump High Temperature Chemical Process Inline Pumps Bulletin C-1.2.21. Dean Pump High Temperature Chemical Process Inline Pumps Series DL Dean Pump Series DL High Temperature Chemical Process Inline Pumps Capacities to 600 GPM (182 m 3 /hr) Heads to 0 feet

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus

More information

Installation, Operation and Service Manual

Installation, Operation and Service Manual Installation, Operation and Service Manual Conforto Electric Furnace KHE 10 TO 27kW INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual in its entirety

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

NM1850 SERVICE PARTS

NM1850 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM0 SERVICE PARTS TABLE OF CONTENTS

More information

AD-360X2 Parts Manual

AD-360X2 Parts Manual AD-360X2 Parts Manual Phase 7 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com

More information

CL & CLG Clamp Mount Mixers

CL & CLG Clamp Mount Mixers CL & CLG Clamp Mount Mixers CL / CLG Series OWNERS MANUAL Warranty Our products are guaranteed against defective materials and workmanship, we will repair or replace such items as may prove defective at

More information

Repair Parts List DRYER MODEL NUMBER MDG32PC3AW. When requesting service or ordering parts, always provide the following information:

Repair Parts List DRYER MODEL NUMBER MDG32PC3AW. When requesting service or ordering parts, always provide the following information: Repair Parts List DRYER MODEL NUMBER MDG32PC3AW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005

More information

AD-30x2R Parts Manual

AD-30x2R Parts Manual AD-30x2R Parts Manual American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com www.amdry.com ADC Part No. 450340-1

More information

Homestyle Stacked Washer/Dryer

Homestyle Stacked Washer/Dryer Homestyle Stacked Washer/Dryer Parts Refer to Page 3 for Model Numbers SWD452C_802847 www.comlaundry.com Part No. 802847R8 August 2012 Table of Contents Title Page Parts Ordering Information... 2 Nameplate

More information

ML-96 Parts Manual. Phase 7

ML-96 Parts Manual. Phase 7 ML-96 Parts Manual Phase 7 2001 American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com www.amdry.com ADC Part

More information

ML-78 Parts Manual. ADC Part No

ML-78 Parts Manual. ADC Part No ML-78 Parts Manual American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com ADC Part No. 450181 Retain This Manual

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

UNIVERSAL 750 PRE-MIX DISPENSER

UNIVERSAL 750 PRE-MIX DISPENSER Anoka, MN. 0 - Telephone -00--00 Facsimile -00--0 MODEL NO. xxx xxx Universal 0 of Control Code A Manual Part No. 00 -- Revised: -- ªIMI Cornelius Co., - Anoka, MN. 0 - Telephone -00--00 Facsimile -00--0

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS EL6XC ELITE Series R-40A Bulletin No. 20833 July 208 Supersedes March 208 SEER up to 7.90.5 to 5 Tons Cooling Capacity - 7,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

CG Section and Base Assembly Series 1 through 12

CG Section and Base Assembly Series 1 through 12 GAS CG Section and Base Assembly Series through 2 5 3 2 2 3 4 9 6 8 0 8B 0A 7 22 Discontinued Service Parts CG Section and Base Assembly Series through 2 GAS Fig. No. Part No. Description Series No. 3-03-85

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2. P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000

More information

AD-236 Parts Manual. 24 VAC Phase 5

AD-236 Parts Manual. 24 VAC Phase 5 AD-236 Parts Manual 24 VAC Phase 5 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com

More information

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5 Section V COOLING SYSTEM CONTENTS Fluid Fan Drive (Silent Flite) 3 Water Pump 4 Radiator 5 Water Temperature Gauge 6 Thermostat 7 Radiator Pressure Cap 7 Service Diagnosis 7 DATA AND SPECIFICATIONS COOLING

More information

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2. G A S F U R N A C E S G61MP ELITE SERIES Multi Position Two Stage Heat E N G I N E E R I N G D A T A Bulletin No. 210382 September 2006 Supersedes August 2006 AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal

More information

ENERVEX GSV GREASE FAN

ENERVEX GSV GREASE FAN ENERVEX GSV 200-450 GREASE FAN 3001391 12.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

Repair Parts List DRYER MODEL NUMBER MDG30PN3AW. When requesting service or ordering parts, always provide the following information:

Repair Parts List DRYER MODEL NUMBER MDG30PN3AW. When requesting service or ordering parts, always provide the following information: Repair Parts List DRYER MODEL NUMBER MDG30PN3AW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Homestyle Stack Washer/Dryers

Homestyle Stack Washer/Dryers Homestyle Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806105 www.alliancelaundry.com Part No. 806105R1 November 2015 Table of Contents Title Page Parts Ordering Information...

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998 Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,

More information

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL www.mkdiamond.com OWNER S MANUAL & PARTS MANUAL Revision 106 03.2019 Manual Part No. 166894 Caution: Read all safety and operating instructions before using this equipment. This manual MUST accompany the

More information

Fan Blades & Accessories

Fan Blades & Accessories D46 WHEN SHOULD YOU REPLACE A PROPELLER? HERE ARE A COUPLE OCCASIONS: Propeller balance is very sensitive. All Lau props are balanced AFTER the label has been applied to the blade. Balance is subject to

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

MLG-52 Parts Manual. Phase 8 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE

MLG-52 Parts Manual. Phase 8 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE MLG-52 Parts Manual Phase 8 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Whirlpool Corporation Commercial Laundry Benton Harbor, MI 49022 1-800-662-3587 Part No. 450366-1 Retain This

More information

5 year fan housing and motor warranty

5 year fan housing and motor warranty MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box

More information

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

GAS DRYER MODELS: (White) (Chrome Shadow) 01/28/ Sears Brands, LLC Part No. W Rev. A

GAS DRYER MODELS: (White) (Chrome Shadow) 01/28/ Sears Brands, LLC Part No. W Rev. A GAS DRYER MODELS: 110.78132413 (White) 110.78133413 (Chrome Shadow) 01/28/2016 2016 Sears Brands, LLC Part W10865713 Rev. A TOP AND CONSOLE PARTS 01/28/2016 2 Part W10865713 Rev. A TOP AND CONSOLE PARTS

More information

GAS DRYER MODELS: WGD8000DW0 (White) 03/30/ Whirlpool Corporation Part No. W Rev. C

GAS DRYER MODELS: WGD8000DW0 (White) 03/30/ Whirlpool Corporation Part No. W Rev. C GAS DRYER MODELS: WGD8000DW0 (White) 03/30/2015 2015 Whirlpool Corporation Part W10743192 Rev. C TOP AND CONSOLE PARTS 03/30/2015 2 Part W10743192 Rev. C TOP AND CONSOLE PARTS Part Description 1 Literature

More information

ML-82 Parts Manual. Phase 7 Microprocessor with F.S.S. Options

ML-82 Parts Manual. Phase 7 Microprocessor with F.S.S. Options ML-82 Parts Manual Phase 7 Microprocessor with F.S.S. Options American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com

More information

AD-444 Parts Manual. ADC Part No

AD-444 Parts Manual.   ADC Part No AD-444 Parts Manual American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com ADC Part

More information

The Heart of any. Air conditioning or refrigeration system. is the Compressor. Compressors usually work or they don't. with little in between

The Heart of any. Air conditioning or refrigeration system. is the Compressor. Compressors usually work or they don't. with little in between 1 of 20 3/11/2012 2:10 PM The Heart of any Air conditioning or refrigeration system is the Compressor. Compressors usually work or they don't with little in between The compressor on an air conditioner

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

AD-115ES Parts Manual 24 VAC Phase

AD-115ES Parts Manual 24 VAC Phase AD-115ES Parts Manual 24 VAC Phase 5 2000 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com

More information

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ MEIKO Undercounter Dish and Glass Washing Machine Spare Parts List FV40.G 08V/0V /-PHASE 60 HZ Rev.. Updated: 0-8-04 CONTENTS. WASH PUMP PAGE. WASH SYSTEM PAGE. BOOSTER PUMP PAGE 7. SOLENOID / FILL VALVE

More information

Home Stack Washer/Dryers

Home Stack Washer/Dryers Home Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806093 www.alliancelaundry.com Part No. 806093R4 September 2018 Table of Contents Title Page Parts Ordering Information... 2 Serial

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE

More information