Fixed Reclaim System

Size: px
Start display at page:

Download "Fixed Reclaim System"

Transcription

1 Fixed Reclaim System Manual P/N English-- Keep for Future Reference Nordson China Sourcing - Shanghai

2 Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF, Can Works, Century, Clean Coat, CleanSleeve, CleanSpray, COLORMAX, Compumelt, Control Coat, Cross-Cut, Cyclo-Kinetic, Dispensejet, DispenseMate, Durafiber, Durasystem, Easy Coat, Easymove Plus, Econo-Coat, EPREG, ETI, Excel 2000, Flex-O-Coat, Flexi-Spray, Flow Sentry, Fluidshooter, FoamMelt, FoamMix, Helix, Horizon, Hose Mole, Hot Shot, Hot Stitch, Isocoil, Isocore, Iso-Flo, KB30, Little Squirt, Magnastatic, MEG, Meltex, MicroSet, Millenium, Mini Squirt, Moist-Cure, MultiScan, Nordson, OmniScan, Opticoat, Package of Values, PluraFoam, Porous Coat, Powderware, Pro-Flo, ProLink, PRX, Rhino, S.design stylized, SC5, SCF, Select Coat, Select Cure, Slautterback, Smart-Coat, Spray Squirt, Spraymelt, Super Squirt, Sure-Bond, Sure Coat, System Sentry, Tela-Therm, Trends, Tribomatic, UniScan, UpTime, Versa-Coat, Versa-Screen, Versa- Spray, Watermark, When you expect more are registered trademarks- - of Nordson Corporation. ATS, Auto-Flo, AutoScan, BetterBook, Chameleon, CanNeck, Check Mate, CPX, Control Weave, Controlled Fiberization, EasyClean, Ebraid, Eclipse, Equi=Bead, Fillmaster, FlexiCoat, Gluie, Ink-Dot, JR, Maxima, MicroFin, Minimeter, Mountaingate, Multifil, OptiMix, Pattern View, PluraMix, Primarc, Prism, Pro-Meter, Pro-Stream, Process Sentry, PurTech, Pulse Spray, Saturn, Seal Sentry, Select Charge, Select Series, Sensomatic, Shaftshield, Spectral, Spectrum, Sure Brand, Sure Coat, Swirl Coat, Vista, Walcom, 2 Rings (Design) are trademarks - - of Nordson Corporation. Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes, could lead to violation of the owners rights.

3 Table of Contents I Table of Contents Congratulations on the Purchase of Your Nordson Product Your Safety is Important to Nordson 0-1 Manufacturer of Equipment 0-1 Nordson Asia Sales Offices 0-2 Section 1 Safety 1. Introduction Qualified Personnel Intended Use Regulations and Approvals Personal Safety Fire Safety Action in the Event of a Malfunction Disposal Intended Use 2-1 Section 2 Equipment Familiarisation 2. Features 2-2 Section 3 Operating Instructions 1. Start-Up Shut-Down and Routing Maintenance 3-1

4 Table of Contents I Section 4 Control Panel Guide 1. Operation of Fan Starter Control Fan Starter Controls Consist of 5-1 Section5 Electrical Requirements Electrical Requirement 5-1 Section 6 System Air Flow Requirements Compressed Air Requirements (Maximum) 6-1 Section7 Maintenance Procedures Tasks To Be Performed 7-1 Section 8 Colour Change Procedure Colour Change Procedure 8-1 Section 9 Troubleshooting 1. Troubleshooting Guide Cartridge Filter Troubleshooting 9-3 Section 10 Commissioning Report Commissioning Report 10-1 Section 11 Powder System Audit Cartridge Filter Troubleshooting 11-1

5 Introduction 0-1 Congratulations on the Purchase of Your Nordson Product Nordson equipment is engineered and manufactured in accordance with strict specifications, using high quality components and state-of-the-art technologies that assure reliable, long term performance. Your Product was thoroughly tested for proper operation prior to shipment. Before unpacking and installing your new equipment, please read this manual. It is your guide to safe installation, productive operation and effective maintenance. We recommend that you keep the manual available for future reference. Your Safety is Important to Nordson Carefully read the Safety section. Your product is designed for safe operation when used according to the published instructions. Potential hazards exist when operating instructions are not followed. Manufacturer of Equipment Nordson China, China Sourcing Operation 828 Xin Jin Qiao Road Pudong New District Shanghai China Telephone: Fax: For a list of local Nordson organizations, see Nordson international.

6 Introduction 0-2 Nordson Asia For your nearest Nordson office contact. The Nordson offices below for detail information. Contact Nordson Phone Fax China (North) Nordson China China (South) Solar Pike Hong Kong Nordson Application Equipment Taiwan Nordson Da Korea Nordson Sang San Philippines Thailand Indonesia Vietnam Nordson South East Asia Australia Nordson Australia New Zealand Nordson New Zealand Malaysia Nordson Malaysia Japan Nordson Japan India Nordson India to South America Latin America Nordson PSD Nordson America USA

7 Section 1 Safety

8 Safety 1-1 Section 1 Safety 1. Introduction Read and follow these safety instructions. Task and equipment specific warning, cautions, and instructions are included in equipment documentation where appropriate, Make sure all equipment documentation, including these instructions, is accessible to all persons operating or servicing equipment. 2. Qualified Personnel Equipment owners are responsible for making sure that Nordson equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable or performing their assigned tasks. 3. Intended Use Use of Nordson equipment in ways other than described in the documentation supplied with the equipment may result in injury to persons or damage to property. some example of unintended use equipment include using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts operating equipment in excess of maximum ratings 4. Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed. Warning: When using the gun mover for liquid paint application, it must be equipped with an E.X.E. (explosion proof) motor. The motor gland, wiring and plug must meet local electrical regulations for a CLASS 1 ZONE 1 environment.

9 Safety Personal Safety To prevent follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety services. Keep clear of moving equipment. Before adjusting or servicing any moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Relieve (bleed off) hydraulic and pneumatic pressure before adjusting or servicing pressurized systems or components. Disconnect, lock out, and tag switches before servicing electrical equipment. While operating manual electrostatic spray guns, make sure you are grounded. Wear electrically conductive gloves or a grounding strap connected to the gun handle or other true earth ground. Do not wear or carry metallic objects such as jewelry or tools. If you receive even a slight electrical shock, shut down all electrical or electrostatic equipment immediately. Do not restart the equipment until the problem has been identified and corrected. Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons.

10 Safety Fire Safety To avoid a fire or explosion, follow these instructions. Ground all conductive equipment in the spray area. Clerk equipment and workpiece grounding devices regularly. Resistance to ground must not exceed one mega-ohm. Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected. Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored. Provide adequate ventilation to prevent dangerous concentrations of volatile materials or vapors. Refer to local codes or your material MSDS for guidance. Do not disconnect live electrical circuits while working with flammable materials. Shut off power at a disconnect switch first to prevent sparking. Know where emergency stop buttons, shutoff valves, and fire extinguishers are located. If a fire starts in a spray booth, immediately shut off the spray system and exhaust fans. Shut off electrostatic power and ground the charging system before adjusting, cleaning, or repairing electrostatic equipment. Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. 7. Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps. Disconnect and lock out electrical power. Close pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the equipment. 8. Disposal Dispose of equipment and materials used in operation and servicing according to local codes.

11 Section 2 Equipment Familiarisation

12

13 Section 3 Operating Instructions

14 Operating Instructions 3-1 Section 3 Operating Instruction 1. Start-Up 1. Turn on compressor or ensure compressed air supply to refrigerant drier. 2. Turn on electrical supply to refrigerant drier either locally or at main booth control panel isolator. 3. Turn the main isolator on the control panel to "on". Push the green "start" button to activate the extraction fan and turn the pulsing (where used) to "on". Turn "on" the booth lights (where used). N.B. After approximately 15 minutes from item 2, compressed air will be passed to booth. 4. With compressed air available start loading conveyor with work or if work present at start of booth, turn power packs on and start oscillators/reciprocators immediately. 2. Shut-Down and Routine Maintenance 1. Turn "off" power packs. Turn "off" the pulsing switch (where used). 2. Remove powder delivery hoses from powder pumps and blow through with compressed air. 3. Clean powder pump by removing and cleaning with compressed air. Refit. 4. Clean nozzles, antenna and sleeves on guns. Note: Ensure gun alignment is not altered. 5. Push red button to "stop" main extraction fan. 6. Turn off compressed air and shut down air dryer. 7. Drain oscillator oil collectors and refill oscillator oiler. 8. Turn off booth lights and main isolator. 9. Cartridge filters: check for seating and tighten if necessary at least once a month.

15 Section 4 Control Panel Guide

16 Control Panel Guide 4-1 Section 4 Control Panel Guide a) INTRODUCTION Fan Starter Control - This panel provides the basic control functions for operation of the booth. b) INSTALLATION The control is normally fitted to the side of the reclaim section. The provision of a mains electricity supply to the isolator incoming terminals situated inside the panel, other minor associated wiring, and of a main compressed air supply to either the control entry bulkhead fitting or to the supply point on the ring main is the responsibility of the customer. Standard booth electrical requirements are given in the following pages. Compressed air requirements will be notified by Nordson personnel but may also be estimated from the compressed air utility requirements stated in this section. Some larger panels may be supplied free-standing. Bolting down is the responsibility of the customer. c) COMPRESSED AIR DRYER A refrigerator type compressed air dryer together with a coalescing type micro filter for removing oil from the air supply is vital to the operation of any powder booth. A compressed air dryer, together with a coalescing filter and a timer/solenoid air valve, to be fitted in a suitable location are normally supplied and the services connected by the customer. Some installations will have the compressed air conditioning equipment supplied, fitted and site wired by Nordson Australia Pty Ltd personnel and this will be agreed during negotiations. Depending upon the degree of automation agreed upon, the dryer and booth may be interlocked to prevent the operation of the booth without a supply of conditioned air, or the correct operation and start sequence may be specified in the operating instructions. With either manual or automatic control of the dryer it should be impossible to spray powder into the booth without a conditioned air supply. 1. Operation of the Fan Starter Control Main Functions The main isolator disconnects the 3 phases input to the control panel. Green push button energises the extraction fan motor contactor and pulse sequence timer board. Red push button performs the opposite function of the green push button and deactivates the circuits. (Additional remote emergency stop buttons may be wired in parallel by the customer.)

17 Control Panel Guide 4-2 Auxiliary Functions 1. Cartridge Cleaning: The time interval between and the duration of each cleaning pulse are selected by the miniature potentiometers mounted on the sequence control printed circuit board, one potentiometer for each timing function, which are clearly marked. Typical timer settings are 9-45 seconds between pulses and 40 milli-seconds for the duration time of the pulse. As 40 milli-seconds requires the use of sophisticated timing equipment to set up on the timing card, experience has equated this to a short sharp "bang" from the powder collector. In each case the set times are dependent upon the powder loading and cartridge cleaning pressure with good cleaning being the object. Some versions are fitted with a programmable type timer board it is preset at the time of manufacture and should not be adjusted at any time. Well cleaned cartridges are normally indicated by differential pressure readings of approximately 0.7 Kpa (2.8 inches water gauge). Readings between approximately 0.25 and 0.75 Kpa would be acceptable for typical installations newly installed and these will rise during the life of the cartridge, progressively up to about 1.1 Kpa (4.4 inches water gauge), and then more rapidly until the maximum differential pressure is reached. (Some installations with high powder loading may run at more than 0.75 Kpa (3 inches water gauge). 2. Powder Recovery - Bulk Feeder Powder Supply: Oversprayed powder collects in the hopper of the recovery section and is pumped out pneumatically. This powder returns to the powder delivery guns to be re-used. To maintain a minimum supply of powder to the fans from the module recovery hopper a Bulk Feeder powder supply can be connected. Looking from the rear of the collector module, the Bulk Feeder inlet is located on the left side at the bottom above the sieve screen level. The level control probe in the supply hopper will sense when more powder is required. The probes will energise a solenoid valve via a dual channel relay in the level control enclosure to supply refrigerated air to the Bulk Feeder pump and activate the vibrator. It is important to check the operation of the Bulk Feeder at every start up of the system along with level of powder in the recovery/supply hopper. 2. Fan Starter Controls Consist of: a) Main Isolator b) Stop button c) Start button d) Filter cleaning on/off switch e) Magnetic gauge

18 Section 5 Electrical Requirements

19 Electrical Requirements 5-1 Section 5 Electrical Requirements ELECTRICAL REQUIREMENTS NOTE: Can be supplied to other voltages. BOOTH / MODULE SIZE MAIN SUPPLY FAN MOTOR LOAD 2 Cartridge Module phase neutral and earth 1.5 Kw 4 Carriage Module phase neutral and earth 3.0 Kw 6 Cartridge Module phase neutral and earth 8 Cartridge Module phase neutral and earth 10 Cartridge Module phase neutral and earth 12 Cartridge Module phase neutral and earth 4.0 Kw 5.5 Kw 7.5 Kw 11.0 Kw These electrical requirements are for installations with average Versa power pack loading. Special installations may have larger requirements due to - Eg. Memory and Detection systems, Versa consoles to replace Versa power pack. Any non-standard electrical requirements will be notified by Nordson representatives before the system is installed.

20 Section 6 System Air Flow Requirements

21 System Air Flow Requirements 6-1 Section 6 System Air Flow Requirements COMPRESSED AIR REQUIREMENTS (MAXIMUM) AIR FLOW Powder Pump to Manual or Automatic gun Feeder Hopper Fluidising Air AH AH23 AH120, AH80 REQUIREMENTS 10 scfm ea. gun 1 scfm ea. Hopper 3 scfm ea. Hopper 20 scfm ea. Hopper Powder Pump to the sieve, from the Collector Hopper. 12 scfm ea. Transfer Pump Recovery Unit Cartridge Pulsing Fluidised Reclaim Hopper 4 scfm/1000 cfm of collector capacity Kpa 30 scfm per Hopper NOTE: All pneumatic functions are controlled from the Air Service Manifold.

22 Section 7 System Clean-Up Steps

23 System Clean-Up Steps 7-1 Section 7 System Clean-Up Steps Tasks To Be Performed With System ON 1. Squeegee down booth On Collector Hoppers On Bulk Hopper With System OFF 1. Clean all Transfer Pumps 2. Clean Sieve Screens 3. Clean Feeder and/or Bulk Hopper Vents (if applicable). 4. Clean Bulk Hopper Cyclone (if applicable). With System ON 1. Check hopper base and fluidising tile for small parts or foreign items. 2. Complete remainder of booth clean-up. Turn Off All Fluidising Air and Transfer Pumps 1. Clean guns/hoses and pumps 2. Clean outside of booth (walls, hoses, oscillator, etc.) 3. Check gun voltages 4. Clean up detectors 5. Mop paint room

24 Section 8 Colour Change Procedure

25 Colour Change Procedure 8-1 Section 8 Colour Change Procedure COLOUR CHANGE PROCEDURE Fixed Reclaim sections are themselves not easily colour changeable and are virtually exclusively used in spray to waste or single colour applications. However, they may be used in conjunction with a booth that may require cleaning in between colours. Should the Fixed Reclaim section ever require to be colour changeable, it is necessary for a set of filter cartridges be kept for each colour used which must be swapped over at colour change time. 1. Clean out spray guns and hoses by disconnecting at pump and blowing clean with air line. Note: Booth extraction fan should be running during this operation (Booth on line). 2. Strip gun and clean internal parts with air line. 3. Roll booth to off line position. (Roll-on/Roll-off arrangement only.) 4. Ensure fan is running and proceed to clean down thoroughly all booth walls and roof, pushing powder into reclaim section. Turn "off" pulse to reduce noise inside booth (where used). The following sequence is suggested for cleaning: Brush or squeegee excess powder from booth. Vacuum booth down. Wipe down with damp, lint-free cloth or chamois. 5. When clean, press the red button to stop the extraction fan.

26 Section 9 Troubleshooting

27 Troubleshooting Guide 9-1 Section 9 Troubleshooting Guide 1. Troubleshooting Guide SYMPTOM FAULT CORRECTIVE ACTION No extract air. Fan not running. (See also sieve faults) Emergency stop open. Supply fuse blown. Motor power phase fuse. Close emergency stop. Check for short circuit and replace fuse. Check for motor faults and replace fuse blown or overload or reset overloads. Check overloads. Open setting against motor running current. Fan runs but cartridges won t clean. (Cartridge clean facility turned on or clean poorly). No output from sequence control card. Output from PCB, cartridges not pulsing. If all output affected, check fuse on PCB If one or more outputs, but not all affected, check trial firing by changing faulty output to unused output if available, or by exchanging connections with functioning output, replace faulty board. Check cleaning rate - ie. Position of potentiometer - increase delay between pulses. Check pressure gauge on recovery module 420 Kpa required. Check to see if cartridge reverse jet is passing air continuously - if so shut system down and replace valve. Check and replace faulty solenoid valve(s) as necessary

28 Troubleshooting Guide 9-2 SYMPTOM FAULT CORRECTIVE ACTION Powder not returning from recovery hoppers No air to transfer pump or fluidised bed. Air to transfer pump, fluidised but not transferring. Check regulator(s) and gauges(s) supplying recovery equipment. Typical operating pressures should be Kpa fluidising and 140 Kpa hoppers, transfer pump. Check nylon hoses for kinking or blockage. Remove air supply. Check transfer pump, spigot into recovery hopper and transfer hose for blockage or obstruction. Remove blockage (blow through with low pressure compressed air) and refit equipment and hoses. Extract fan running but no powder from the guns. Powder pack mains, local to pack or on main panel (where isolator incorporated) but not on. Pack switches on but no powder from the gun. Turn pack(s) on. Turn control panel off at isolator. Check fuse in feed to packs. Check compressed air to pack. Check powder pump for blockage. Check compressed air to powder pump. Check powder delivery hose for blockage. Check hopper for sufficient powder. Check powder flow rate and atomising air settings on pack. Atomising air typically psi. Flow rate typically psi. Sieve not running. Sieve unplugged Plug in sieve (gyratory only) Fan running, sieve not running but turned on. Magnetic switch on inspection door of rotary sieve not made. Sieve fuses blown or over-load tripped. Close door securely - restart system. Shut down system. Check for faults. Replace fuses in sieve supply, or reset overload.

29 Troubleshooting Guide Cartridge Filter Troubleshooting Short Filter Life no dust pass through 1. Moisture Problems Wavey pleats. Total plug-pleat bridging (see below) Remove moisture. Remember moisture source may not be in collector area such as air lines. Filter appears to be affected by moisture but none can be found. Check paint for wax content. 2. Collector Design Problem Total plug-pleat bridging. Check to see if deflector shield from booth to collector has been installed. Deflector must extend below cartridges to allow reverse pulse to work. 3. Reverse Pulse Pressure Problem Total plug-pleat bridging. Check reverse pulse pressure to see that it is in approximately Kpa. More or less is not normally better. Dust Pass Through 1. Seal Problems Check sealing gasket to be sure it is clean and properly installed. It is important that you do not skimp on adhesive in field retrofits. This is one area where more is better! On models which use the old configuration with centre post bolts be sure new post seal is installed and sealed with RTV if necessary. Be sure nut has not been over torque. Be sure that tube sheet and surrounding area where gasket will be seating has been cleaned. Filter looks to be operating fine but dust is coming out of final filters or final filters are clogging up prematurely. Have powder analysed - it may be too fine to be caught by filters.

30 Troubleshooting Guide Damage Problems Visually check cartridges for damage. 3. Construction Problems Check all piping and seams on system. Pay particular attention to joints between booth and collector. Inspect joint between tube sheet and venturi for gaps and leaks. Cartridge Maintenance When new cartridges have been installed, a re-tightening check should be made after eight (8) hours of operation. Cartridge media can fail for a number of reasons: 1. Pleat failure due to normal wear. 2. Pleat failure from using a high pressure blow gun to clean the exterior/interior of the cartridge. 3. Defective media. 4. Damage during shipment ie. dented or bent. 5. The powder has very fine particles which pass through the media. 6. Certain media disintegrates if it is contaminated with oil or water. 7. Expanded metal support has punctured the media.

31 Troubleshooting Guide 9-5 General Maintenance Make regular inspection checks on: 1. Condition of fluidising tile - replace if damaged or shows signs of blocked pores. 2. Condition of sieve material - holes or blocked areas. Replace if faulty. 3. Sieve vibrator operation. 4. Diaphragm valve operation - see attached data sheet. 5. Possible leakage of powder from collection section to clean air (fan section). If powder is present in or after the clean air section, then checks must be carried out to find source. (a) (b) A break or hole has appeared in the cartridge support plate (partition between the two sections) - possibly where it is sealed around cabinet housing. One (or more) of the cartridges is not sealing to plate due to fault in the gasket, not fully tightened, or distortion in the tube plate. (See cartridge replacement.) Cartridge Replacement While having someone else support the cartridge, remove the top nut and associated hardware and remove the cartridge. Clean the tube plate to provide a positive sealing surface. Remove the hanger from the cartridge by removing the single nut, washer and rubber washer. Re-fit to new cartridge. Install the new cartridge in the reverse order of removal. PLEASE REFER TO DRAWINGS/DIAGRAMS AND COMPONENT BROCHURES AT THE END OF THIS MANUAL.

32 Section 10 Commissioning Report

33 Commissioning Report 10-1 Section 10 Commissioning Report PRODUCT: COMMISSIONING REPORT GUNS: Atomising Flow rate Nozzle C = Cone Nozzle F = Flat Oscillator Stroke Length Up pressure Down Pressure GUN ONE GUN TWO GUN THREE GUN FOUR GUN FIVE GUN SIX CONTROLS: INSTRUMENT FUNCTION ACTUAL SETTING RECOMMENDED SETTING *PS1 Final filter DP 10 Mbar *PS2 Cartridge filter DP 10 Mbar *T2 Slugging relay timer 10 sec *T1 Dual hopper recycle / As needed timer Magnahelic Cartridge DP / Kpa Pulse timer Cartridge cleaning / Frequently dependent upon number of cartridges. Duration of 40ms. PRESSURE REGULATOR SETTINGS: INSTRUMENT FUNCTION ACTUAL SETTING RECOMMENDED SETTING R1 Fluidising Kpa R3 Pulsing 415 Kpa R7 Module Pump-out 40 Kpa Check for correct seating of all cartridge filters and tighten to approximately 7nm (5ft-lb). Check for correct seating of all cartridge filters and tighten if necessary.

34 Section 11 Powder System Audit

35 Powder System Audit 11-1 Section 11 Powder System Audit CUSTOMER: AUDITOR: DATE: / /. PART ONE - GENERAL POWDER SYSTEM AUDIT A. B. C. Record pressure drop across filter. Pulse / blowdown cycle (time between) Pulse / blowdown cycle duration Kpa Sec Sec PART TWO - BOOTH NO. ITEM YES NO COMMENT 1. Any evidence of exterior powder leakage. If yes where? 2. Is pulse air pressure 415Kpa 3. Any evidence of cartridge / filter leakage? If yes, describe. 4. Are all the cartridges sealed tight? 5. Is the fan operation normal? Check for correct direction of rotation 6. Is the differential pressure switch operational? (If fitted) 7. Is the final filter in good condition? If no, describe. 8. Is the manometer function normal? N/A 9. Is the powder level control functional/ (if fitted) 10. Do system powder pumps function properly? 11. Is collector & blower securely mounted? 12. Is the tubing neat, well supported and free of damage or wear? Is collector & other recovery system components electrically grounded? Are ground straps intact and undamaged?... Ohms to building ground

36 Powder System Audit 11-2 UV DETECTION SYSTEM (IF FITTED) NO. ITEM YES NO COMMENT 1. Has UV Check # 1 been done? VDC Pulse to VDC. Every... Sec 2. Has UV check # 2 been done? Any How many?... bulbs replaced? 3. Has UV check # 3 been done? Set at level Has UV check # 4 been done? VDC to Ground 5. Has UV check # 5 been done? 6. Are air shields at detector properly located and functional? 7. B to Ground 8. C to Ground to A to D1 11. A to D2 12. A to D3 13. A to D4 MINI - CYCLONE/SIEVE Operating PSI NO. ITEM YES NO COMMENT Evidence of external leakage of powder from this equipment? If yes, describe. Does sieve vibrate properly? If no, describe. Are mini-cyclone, sieve & stand secured together and to the floor? Is tubing neatly dressed, supported and free from damage or wear? Is system connected to building ground? If grounding straps are used, are they intact and undamaged?... Ohms to building ground.

37 Powder System Audit 11-3 HOPPER - RECYCLE NO. ITEM YES NO COMMENT 1. Is there any evidence of powder leaks from this device? If yes, describe. 2. Is negative pressure evidence inside hopper? 3. Is fluidising function normal 60 to 100 Kpa? 4. If used, is float control operation normal? If not, describe. 5. Is hopper properly vented? 6. Is tubing heat, supported & free from damage or wear? 7. Is hopper connected to building ground?... Ohms to building ground. BOOTH NO. ITEM YES NO COMMENT 1. Is illumination suitable? If not, describe. 2. Is powder overspray being captured efficiently? 3. Is air velocity through each spray enclosure opening greater than 60 FPM? If no, record velocity. 4. Note the required frequency of...hours cleaning 5. List the total air flow (CFM) through Avg. FPM x total the booth opening in sq. Ft. = CFM 6. List worst condition powder/air - Oz Ft³ concentration for this booth Powder lbs/hr x 16 x No. Of guns. 7. Is system connected to building ground? 8. Is booth location 900mm from combustible construction? 9. Are sprinklers provided for fire control?...oz/ft³...60 x cfm... Ohms to building ground

38 Powder System Audit 11-4 GUNS & POWDER SUPPLY NO. ITEM YES NO COMMENT 1. Any evidence of damage or excessive wear? If yes, describe. 2. Can spray pattern be adjusted properly? 3. Is handgun triggering reliable? 4. Is there evidence of powder leakage into the gun resistor cavity? 5. Does reciprocator or oscillator function properly? 6. Do all switches function properly? 7. Do pilot lights function properly? 8. Does the overcurrent protection circuit trip and reset properly? 9. Does exhaust monitor interlock function reliably? (If fitted) 10. Does the fire alarm interlock function properly? (If fitted) 11. Does the conveyor interlock function reliably? (If fitted) 12. Has dielectric grease been installed in each gun? INFORMATION ON POWDER BEING USED 1. Manufacturer: 2. Specification Number: 3. Colour: 4. Shipping container size: 5. Any moisture problems: Yes No If yes: Explain:

39 Powder System Audit 11-5 GUN AND POWDER SUPPLY INFORMATION NO. ITEM Ejector pressure - PSI 2. Diffuser pressure - PSI 3. Gun output voltage at KV setting 4. Gun output voltage at KV setting 5. Gun output voltage at KV setting 6. Power pack output voltage at KV setting 7. Power pack output at KV setting. GENERAL INFORMATION - SPRAY ROOM & SURROUNDING AREA NO. ITEM YES NO COMMENT 1. Is wiring installed in a business-like manner and enclosed in proper circuit? 2. Is an electrical disc. Lock-out provided on main power input? 3. Are dust tight approved enclosures used in all classified areas? 4. Is conveyor rail firmly connected to building... Ohms to building ground. ground? 5. Is work piece adequately grounded to the... Ohms to building ground. conveyor? 6. Are conveyor hooks clean? 7. Is conveyor provided with a single start station? If no, explain. 8. Is area housekeeping vacuum cleaner on hand? 9. Is an industrial vacuum cleaner on hand? 10. Are instruction manuals for all equipment on hand and easily accessible? 11. Are operators & supervisors adequately trained to safely operate the equipment? Date of school Any obvious ignition sources within two (2) meters of the spray booth. 13. Any flammable liquids or materials stored in the area? 14. Adequate emergency exit from area? 15. Are fire control sprinklers installed? 16. Is a fire alarm system installed? 17. Is the fire alarm tested routinely 18. Are lights within six (6) meters of the spray room guarded? 19. Is make-up air adequate?

40 Powder System Audit 11-6 GENERAL INFORMATION - SPRAY ROOM & SURROUNDING AREA GENERAL INFORMATION NO. ITEM YES NO COMMENT 1. Are routine safety checks conducted? 2. Are no smoking signs posted in powder coating area? 3. Is no smoking ban enforced? 4. Is warning tag number posted? 5. Have operating personnel attended a Nordson powder school? How many? Have regional Customer Service Representatives been trained? AIR DRYER NO. ITEM YES NO COMMENT 1. Is unit properly sized? CFM rating... Suction pressure gauge Does condensation drain function properly? 3. Does coalescent filter operate? 4. Is the correct size piping used for the system? 5. Is air prefilter operational? 6. Has a time delay lockout been installed? OVERALL COMMENT: AUDIT APPROVAL BY CUSTOMER Approval By: Nordson Representative: Nordson Regional Representative: Date Completed: Title Title Title

41 Section 12 Drawings

42 Drawings 12-1

Envirocoat Twin Cyclone Powder Coating Booth

Envirocoat Twin Cyclone Powder Coating Booth Envirocoat Twin Cyclone Powder Coating Booth Manual P/N 779166 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue

More information

Powder Conditioning System

Powder Conditioning System Powder Conditioning System Manual P/N 779168 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Table I Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF,

More information

U7698E Flame Detector

U7698E Flame Detector U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General

More information

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD Electropneumatic Hot Melt Application Heads Manual P/N 409 090 A English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson

More information

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT Sponge Cleaner Manual P/N 768 651 A English Issued 05/03 NORDSON (UK) LTD STOCKPORT Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected

More information

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION Fill Sentry Automated Fill System Customer Product Manual Part NORDSON CORPORATION www.nordson.com CAUTION: If this equipment is used with other Nordson equipment, refer to the manuals provided with that

More information

Hot Melt Application Head Series PW...

Hot Melt Application Head Series PW... Hot Melt Application Head Series... Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

Hot Melt Material Applicator MC 6

Hot Melt Material Applicator MC 6 Hot Melt Material Applicator Manual P/N 403 022 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK Manual P/N 768 643 A English NORDSON (UK) LIMITED STOCKPORT UK Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original

More information

Bulk Melters BM 200 with Piston Pump for 200 l Drums

Bulk Melters BM 200 with Piston Pump for 200 l Drums Bulk Melters BM 200 with Piston Pump for 200 l Drums Manual P/N 464 937 B - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number

More information

Hot Melt Material Applicator MC 12 / MC 24

Hot Melt Material Applicator MC 12 / MC 24 Hot Melt Material Applicator Manual P/N 403 076 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Hot Melt Applicator MC 405 for Foil Bags

Hot Melt Applicator MC 405 for Foil Bags Hot Melt Applicator for Foil Bags Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual is for products with the following P/N: 8015767 8022490 8027924 8037680 8018042 8023117 8031127

More information

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Manual P/N 464 958 C - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order

More information

Drum Melters DG 21 / DG 201

Drum Melters DG 21 / DG 201 Drum Melters DG 21 / DG 201 Manual P/N 464 839 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products

More information

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging

More information

Seal Sentry Series 10 Bead Detection System

Seal Sentry Series 10 Bead Detection System Seal Sentry Series 10 Bead Detection System Customer Product Manual P/N 321 289D02 This equipment is regulated by the European Union under WEEE Directive 2002/96/EC). See www.nordson.com for information

More information

Level Monitor LA 100

Level Monitor LA 100 Level Monitor LA 100 Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS www.nordson.com Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which

More information

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10 ColorMax Engineered Booth Customer Product Manual Issued 11/10 For parts and technical support, call your nearest Finishing Customer Support Centre. Find your nearest centre at www.nordson.com/directory

More information

FC-2200 Flame Detector

FC-2200 Flame Detector FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Liquid Adhesive Detection System Alarm Box

Liquid Adhesive Detection System Alarm Box Liquid Adhesive Detection System Alarm Box Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Eclipse Self-Check UV Scanner

Eclipse Self-Check UV Scanner 856 Instruction Manual 10/18/2010 Eclipse Self-Check UV Model 5602-91 Version 1 Introduction The self-check UV is used for continuous gas or oil flames. A mechanical shutter in the scanner closes briefly

More information

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide Installation Guide P/N 1028657A Econo-Coat RCM 8000 Powder Spray Booth Installation Guide WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

COBRA -H EXTRACTOR 120V

COBRA -H EXTRACTOR 120V COBRA -H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

More information

LA 820 / LA 820 RC Liquid Adhesive Gun

LA 820 / LA 820 RC Liquid Adhesive Gun Liquid Adhesive Gun Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by

More information

BLAST-IT-ALL BUMPER BLASTER

BLAST-IT-ALL BUMPER BLASTER LARRY HESS AND ASSOCIATES, INC 185 PIPER LANE / SALISBURY, NC 28147 PHONE: 1-800-535-2612 / FAX: 1-704-638-9311 WWW.BLAST-IT-ALL.COM BLAST-IT-ALL BUMPER BLASTER SUCTION BLAST CABINET NOTE: It is the responsibility

More information

MARTIN Insertable Dust Collector

MARTIN Insertable Dust Collector MARTIN Insertable Dust Collector Go to MARTIN Insertable Dust Collector web page Operator s Manual M3416 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF

More information

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION The powder coating spray system is designed for the surface preparation and painting of mines of various configurations,

More information

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM 216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine

More information

FS10-R30 Flame Detector

FS10-R30 Flame Detector FS0-R0 Flame Detector Customer Product Manual Part 00-0 Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (00) - or contact your local Nordson representative.

More information

ACT Cartridge Dust Collector

ACT Cartridge Dust Collector IOM-101-1 ACT Cartridge Dust Collector Installation and Operation Manual ACT Dust Collectors CAUTION! Accidents happen, be careful and always follow all local and federal regulations! Fires and explosions

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

Hot Melt Material Applicator MC 7

Hot Melt Material Applicator MC 7 Hot Melt Material Applicator MC 7 Parts List P/N 735003A English Issued 2/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation

More information

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA Customer Product Manual Issued 10/08 NORDON CORPORATION AMHERT, OHIO UA afety... 1 Qualified Personnel... 1 Intended Use... 1 Regulations and Approvals... 1 Personal afety... 1 High-Pressure Fluids...

More information

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model Part456A NORDSON CORPORATION. AMHERST, OHIO USA Corporation welcomes requests for information, comments and inquiries about its products.

More information

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters Instruction Sheet P/N 069-0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Wear an

More information

HR Powder Feed Hopper

HR Powder Feed Hopper Instruction Sheet P/N 106977E0 Description This instruction sheet provides specifications; installation and operation instructions; and parts lists for the HR-16-150 powder feed hopper. The hopper is shipped

More information

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd 1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk

More information

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters Instruction Sheet P/N 069A WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description This

More information

51AKS I S O OWNER S MANUAL

51AKS I S O OWNER S MANUAL LLOYD'S REGISTER QUALITY ASSURANCE 51AKS I S O 9 00 1 OWNER S MANUAL This manual applies to the following models Stand-alone Split 51AKS 085--- 51AKS 010--- 51AKS 185--- 51AKS 013--- 51AKS 113--- 51AKS

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

Hot Melt Material Applicator MC 4420

Hot Melt Material Applicator MC 4420 Hot Melt Material Applicator Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is

More information

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

UV Scanner. Model Specification. Introduction. 854 Instruction Manual 854 Instruction Manual 10/11/010 UV Model 5600-91 C US Introduction This sensor features a high temperature and high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames in applications that

More information

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Hot Melt Applicators SB60 BoD

Hot Melt Applicators SB60 BoD Hot Melt Applicators Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson articles Note

More information

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES Illustrated Commentary Office of the Ontario Fire Marshal Combustible Dust Illustrated Commentary 1 Mechanical Exhaust Systems 5.10.1.1.

More information

Indirect gas-fired air heater

Indirect gas-fired air heater Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be

More information

MULTIPLEX SELF RECUPERATIVE gas burner

MULTIPLEX SELF RECUPERATIVE gas burner Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and

More information

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV 120 VOLT WET / DRY VAC 4 Gallon / 15.14 Liter Part No. PB408SV FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. OPERATOR S MANUAL TABLE OF CONTENTS SECTION

More information

MJC Cartridge Filter Unit Operation & Maintenance

MJC Cartridge Filter Unit Operation & Maintenance 1 of 19 Hodge Clemco Ltd MJC Cartridge Filter Unit Operation & Maintenance Owner s Manual Date of Issue: 19.07.04 TSSM536.1a Hodge Clemco Ltd Orgreave Drive Sheffield S13 9NR Tel: 0114 254 8811 Fax: 0114

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING

More information

Eclipse 90 UV Scanner Model A Version 1

Eclipse 90 UV Scanner Model A Version 1 85 Instruction Manual 10/14/010 Eclipse 90 UV Model 5600-90A Version 1 C US Introduction This sensor features a high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames that cycle on and

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

ColorMax Cyclone Cleaning Kit

ColorMax Cyclone Cleaning Kit Instruction Sheet P/N 637 0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description See

More information

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1. 08-000.02/ 1 2011JA14 SECTION 08-000.02 GENERAL DESCRIPTION See Figure 1 for a schematic diagram of the. See the Nova LFS parts manual for a detailed schematic of the. The function of the vehicle s is

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. I P/N 89104461 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP Receiving Do a quick visual inspection on the truck for any major damage prior to signing the paperwork. Damage should be noted

More information

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-2-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to elements

More information

DuraDrum Bulk Melters DD200

DuraDrum Bulk Melters DD200 DuraDrum Bulk Melters Manual English Issued 11/07 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

Series AD-31 and Series L4 Extrusion Handguns

Series AD-31 and Series L4 Extrusion Handguns Series AD-31 and Series L4 Extrusion Handguns Customer Product Manual Issued 5/05 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter documentation. Nordson Corporation

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL 216300-000 rev2 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OSE OSX (this page intentionally left blank) IDENTIFYING YOUR SYSTEM IOM216300-000 The HOTSTART

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UG2000D UG2000DM UNI-RAM CORPORATION ONTARIO CANADA REVISION 2015-08 INTRODUCTION Uni-ram holds many patents on designs used in its

More information

general brochure

general brochure industrial sandblasting cabinets ISTblast offers a complete line of superior quality industrial sandblasting cabinets designed to accomplish any light to heavy-duty sandblasting jobs. All our cabinets

More information

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DF400/DF600. Construction Heaters. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction

More information

XLT-60 EXTRACTOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

XLT-60 EXTRACTOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL XLT-60 EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 56041883 IMPROPER USE OF THE MACHINE WILL VOID THE

More information

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00 I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP Title WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Procedure No. Installation & Start UP Procedure Author Chris Giordano Effective 1/23/17 Revision A Submitted By Chris Giordano Supersedes Date Revision

More information

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE Ambassador 20 Automatic Carpet Scrubber Model: C8420-115 C8420-240 OPERATION SERVICE PARTS CARE This manual is furnished with each new Minuteman Ambassador 20. This provides the necessary operating and

More information

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters Operating Instructions for the BBO-1 and BBO-2 Basket Blasters 2101 West Cabot Boulevard Langhorne, PA 19047-1893 www.empire-airblast.com Page 2 Model Number: Serial Number: Date of Purchase: Date of Installation:

More information

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER USER MANUAL UPP7500E2 AUTOMATIC PRESSURE POT CLEANER UNI-RAM CORPORATION ONTARIO CANADA REV 2012-12 INTRODUCTION Uni-ram holds many patents on designs used in its innovative products. Every machine is

More information

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics -

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Manual - English - Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note After approx. December 2003, this manual applies to the entire series.

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

PS-2/ES Automated pack & tag machine with IndES fastening system

PS-2/ES Automated pack & tag machine with IndES fastening system English Manual PS-2/ES Automated pack & tag machine with IndES fastening system Contents 1. Introduction 2. Important Safety Instructions 3. PS-2/ES 4. Unpacking the machine 5. Setting up the machine 6

More information

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners 1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):

More information

MODEL MW200 MODEL MW600 AIR DRYER

MODEL MW200 MODEL MW600 AIR DRYER OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0

More information

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WHAT S IN THE PACKAGE? This Operation Manual. (1) Vacuum Sealer. (1) E-(unit size) Heating Element, inside the manual sheet protector.

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control Australian Version Electronic Wall Control 1 Introduction The BR342 reverse cycle rooftop air-conditioner is designed for installation onto Recreational Vehicles (RV s) at the time of manufacture or as

More information

T1 SCRUBBER DRYER OPERATOR MANUAL

T1 SCRUBBER DRYER OPERATOR MANUAL T1 SCRUBBER DRYER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk Web:

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence. MANUAL COVER We at Larry Hess & Associates, Inc. would like to take this opportunity to thank you for your patronage. The machine you have purchased has been manufactured and assembled in the USA with

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an

More information

Gallery Electric Fireplaces

Gallery Electric Fireplaces Gallery Electric Fireplaces Homeowner s Installation Instructions & Operating Manual Model: GBI-34, GBI-41 Only use this heater as described in this manual. Any other use is not recommended by the manufacturer,

More information

COBRA -300H EXTRACTOR

COBRA -300H EXTRACTOR COBRA -300H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

ENVIRO-PAK. Operation and Maintenance Manual. Manufacturer of

ENVIRO-PAK. Operation and Maintenance Manual. Manufacturer of ENVIRO-PAK H Series Single Chamber Compactor Operation and Maintenance Manual Manufacturer of ENVIRO-PAK SAFESUB WINDCHILLER 800-737-5533 WWW.ENVIRO-PAK.NET SALES@ENVIRO-PAK.NET 4308 West Admiral Doyle

More information

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS OPERATING MANUAL SPRAY GUN CLEANERS UG1000 - UG3000 SERIES PATENTS USA 4,788,836 CANADA USA 5,213,117 ENGLAND EUROPE 0300248 ITALY SWEDEN 0300248 GERMANY FRANCE 8110528.0 JAPAN UNI-RAM CORPORATION ONTARIO

More information

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES PATENTS U.S.A. 4,785,836 CANADA 1293909 U.S.A. 5,213,117 ENGLAND EP 0300248 (UK) EUROPE 0300248 ITALY 69760/BE/92 SWEDEN 0300248 GERMANY DE 38

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED

More information

hp Dust Collector With Vacuum Attachment

hp Dust Collector With Vacuum Attachment Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N PROAIR Air Conditioner CR43 Model INSTRUCTION MANUAL Rev. H P/N 10-1008-130 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information