1 Automatic Waste Water Lifting Unit Type Series Booklet

2 Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without KSB s express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft Frankenthal

3 Contents Contents Building Services: Drainage Main applications... 4 Fluids handled... 4 Operating data... 4 Designation... 4 Design details... 4 Materials... 4 Product benefits... 5 Certification... 5 Technical data... 5 Characteristic curve... 5 Connections... 6 Dimensions... 7 Installation example... 7 Scope of supply... 8 Accessories

4 Building Services: Drainage Building Services: Drainage Designation Example: C Key to the designation Code Ama-Drainer-Box Mini C Description Type series Small waste water lifting unit Variant for aggressive fluids Design details Design Collecting tank made of impact-resistant plastic, for floor or wall mounting Odour-proof cover with activated carbon filter and integrated overflow protection Submersible motor pump which starts and stops automatically, with special float Integrated swing check valve To EN Type of installation Stationary above-floor installation Connections Inlet DN 50/ DN 40/ DN 32 Discharge outlet DN 40 Shower connection DN 50 Main applications Single-pump units: above-floor box Mini Automatic drainage of washbasins, showers, washing machines, dishwashers, etc. DN 40 spigot and socket connection can be fitted at the site for venting Drive Single-phase a.c. motor Integrated temperature switch With cable and shock-proof plug Fluids handled Impeller type Standard variant Slightly contaminated water Open multi-vane impeller, free passage of 10 mm Variant C Variant C Material variant for aggressive waste water Aggressive fluids is not suitable for sewage from urinals and toilets. For these applications, please use our minicompacta sewage lifting units. Materials Overview of available materials Operating data Operating data Characteristic Flow rate Head Temperature of fluid pumped Q up to 10 m3/h (2.8 l/s) H up to 6.5 m t up to 35 C1) Component Collecting tank Pump Polypropylene See description for Ama-Drainer N 301 (C) 1) Up to 3 minutes for waste water from the hot water cycle of washing machines and dishwashers for non-industrial use. 4

5 Building Services: Drainage Product benefits Impact-resistant plastic collecting tank Ready-to-connect, easy installation and commissioning Integrated swing check valve Shower connection as standard Certification Certification Effective in: Comment Europe All sizes Technical data Selection table Ama-Drainer-Box Submersible waste water pumps Mat. No. [kg] With Ama-Drainer N P 1 P 2 50 Hz 1~230 V Power cable H07RN-FG [kw] [kw] I N [A] [m] [mm 2 ] Mini 2) 301 SE x Mini C 2) 301 SE/C x Characteristic curve 8 0 US.gpm IM.gpm H [m] [ft] N Q [m 3 /h] [l/s] 4 2) Supplied fully assembled ex works 5

6 Building Services: Drainage Connections Connections Connections Connection Description Inlet / discharge outlet 1+2 Socket DN 50, horizontal optional for inlet with special pipe part DN 50/ DN 40/ DN 32 for discharge outlet special pipe part DN 40 Inlet 3 Socket DN 50, vertical for inlet with special pipe part DN 50/ DN 40/ DN 32 Connection to washing machine possible via Y-drain pipe Auxiliary connections Cable gland 4 Cable grommet, diameter 48 mm Shower connection 5+6 Special pipe part, outside diameter 50 mm, either right or left Venting 7 Carbon filter insert with overflow protection. Wherever possible, leading the vent pipe out of the roof is recommended (max. outside diameter 40 mm). 6

7 Building Services: Drainage Dimensions 75 A A 328 B B (1) 95 (2) (3) Dimensions [mm] (1) Cut-in level standard design (2) Cut-in level shower design (3) Cut-out level standard and shower design A Inlet / discharge outlet B Shower connection Installation example 7 6 H Installation example 1 Inlet 2 Waste water lifting unit 3 Discharge line 4 Socket gate valve 5 Valve preventing backflow into the shower basin 6 Flood level 7 Backflow loop H Pipe loop min. 150 mm 7

8 Building Services: Drainage Scope of supply Small, ready-to-connect waste water lifting unit consisting of: Stable plastic collecting tank with pressure-sealed, odour-proof cover Inlet-side connections (rubber sockets) 2x DN 50/ 2x DN 40/ 1x DN 32 Discharge-side connection DN 40 (rubber socket) Shower connection DN 50 (special pipe part) Carbon filter insert with overflow protection Submersible motor pump which starts and stops automatically, with integrated swing check valve Accessories Electrical accessories Item Description M 1 alarm contactor Magnetic float switch as contactor for alarm switchgear AS 0, AS 2, AS 4 and AS 5 with 5 m connection cable Mat. No [kg] 0,8 Alarm switchgear Item Description Mat. No. [kg] Alarm switchgear AS 0, AS 2, AS 4 with circuit breaker, piezoceramic signal transmitter, 85 db(a) at a distance of 1 m and 4.1 khz, green equipment-on lamp Plastic housing IP 20, 140 x 80 x 57 mm; use float switch, F 1 moisture sensor (item E 64), M1 alarm contactor, or signal relay of control unit as contactor. E 50 AS 0 mains-dependent , ,5 E 51 AS 2 mains-dependent with volt-free signalling contact E 52 E 53 E 55 AS 4 mains-independent with volt-free signalling contact/battery buffer and selfcharging power supply unit (for 5 hours' operation in the event of power failure) Alarm switchgear AS 5 Mains-independent, with self-charging power supply unit for 10 hours' operation in the event of power failure, mains pilot LED, fault indicator light, horn-off push button, volt-free contact for hook-up to a control station, ready for connection with 1.8 m cable and plug. ISO housing IP 41, 190 x 165 x 75 mm, use float switch (E 60) or signal relay of control unit as contactor Alarm equipment (e.g. horn) E V ~/ 12 V = 5 VA Alarm switchgear AS 1 in ISO plug housing IP 30, mains-independent, with self-charging power supply unit for 5 hours operation in the event of a power failure, acoustic signal 70 db(a) with circuit breaker and integrated signal transmitter with 3-metre connection cable, max. 60 C, not suitable for steam and condensate. Alarm transmission options: Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms subject to a flooding risk, e.g. the cellar or next to the washing machine in the kitchen or bathroom. 230 V ~/ 9 V = 1,5 VA , , ,9

9 Building Services: Drainage Item Description Mat. No. [kg] E 64 Moisture sensor F ,2 E70 As contactor for AS 0, AS 2 or AS 4 alarm switchgear or LevelControl, with 3-metre connection cable, 40 C max., not suitable for steam and condensate. Possible applications for alarm transmission: - Water alert signal at a water level of just 1 mm (!) by placing the contactor on the floor of rooms subject to a flooding risk, e.g. the cellar or next to the washing machine in the kitchen or bathroom. Horn, 12 V DC, 105 db(a), 1.2 W For indoor and outdoor installation, to be mounted in a position where it is protected from direct rain, IP 54 enclosure ,1 E 330 KSB washing machine interrupter Alarm triggered, with automatic interruption of power supply to the washing machine if the water level in the collecting tank is too high 230 V AC, 50/60 Hz, max. 16 A ohm resistive load Includes: Housing with socket and plug Buzzer Automatic re-start M 1 K contactor with 5-metre connection cable ,279 9

10 KSB Aktiengesellschaft Frankenthal Johann-Klein-Str Frankenthal (Germany) Tel Fax /01-EN

Automatic Waste Water Lifting Unit

Automatic Waste Water Lifting Unit Type Series Booklet 2331.55/4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins,

More information

mini-compacta Type Series Booklet

mini-compacta Type Series Booklet Floodable Sewage Lifting Unit 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet Submersible Waste Water Pump Ama-Drainer N 301/302/303 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303 All rights reserved. The contents provided herein

More information

Calio-Therm S NC/NCV Type Series Booklet

Calio-Therm S NC/NCV Type Series Booklet High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must

More information

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet Submersible Waste Water Pump Ama-Drainer N 301/302/303/358 Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303/358 All rights reserved. The contents provided herein

More information

Vertical Ring-section Pump WKTB. Type Series Booklet

Vertical Ring-section Pump WKTB. Type Series Booklet WKTB Type Series Booklet Legal information/copyright Type Series Booklet WKTB All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for

More information

50 Hz. Submersible Waste Water Pumps

50 Hz. Submersible Waste Water Pumps Type Series Booklet 2337.51--10 Ama-Drainer r N 301/302/303 Submersible Waste Water Pumps 50 Hz Ama-Drainer R N 301 Ama-Drainer R N 302 Ama-Drainer R N 303 Applications F Automatic drainage of pits, shafts,

More information

Cleaning System. Amajet. Type Series Booklet

Cleaning System. Amajet. Type Series Booklet Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Lifting Plants Product Overview

Lifting Plants Product Overview Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing

More information

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted

More information

Building Services. KSB Building Services. A Real Welcome Home.

Building Services. KSB Building Services. A Real Welcome Home. Building Services KSB Building Services. A Real Welcome Home. 2 Introduction Build the future with KSB. Whether you earn your living by installing or selling pumps, valves and systems, or want to make

More information

Technical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP

Technical data. Unilift KP. CRUNDFOS ~ ozpump.com.au Drainage pumps. Unilift KP Pumped liquids The pump is suitable for clean, non-aggressive water slightly dirty (grey) wastewater. The open-impeller construction ensures the free passage of solids up to 00 mm. Functions -5 Automatic

More information

TYPE POS Oil Shield Sump Pump

TYPE POS Oil Shield Sump Pump Type POS Oil Shield Provides protection for the environment by preventing oil products from entering sewer systems, environmentally Sensitive River and waterways, while protecting equipment and areas from

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Pump overview

More information

JUNG PUMPEN LIFTING STATIONS

JUNG PUMPEN LIFTING STATIONS JUNG PUMPEN LIFTING STATIONS POWERFUL AND DEPENDABLE RESIDENTIAL TECHNOLOGY LIFTING STATIONS Product overview: Lifting stations the full range: Lifting stations are designed to dispose of wastewater in

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Wastewater definitions

More information

MULTISAN Fully automatic sewage and waste water pump

MULTISAN Fully automatic sewage and waste water pump MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where

More information

FEATURES. Other Fed-Flush Arrangements

FEATURES. Other Fed-Flush Arrangements Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC 2CKA001473B9007 19.05.2017 System Manual Busch-Infoline Handicapped toilet signal set 1510 UC-... -101 Table of contents Table of contents 1 Notes on the instruction manual... 3 2 Safety... 4 2.1 Information

More information

LS Condensate Removal Pump Installation, Operation and Service Instructions

LS Condensate Removal Pump Installation, Operation and Service Instructions Bell & Gossett Instruction Manual 6-71-075-115 LS Condensate Removal Pump Installation, Operation and Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. WARNING: This safety

More information

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology DRAINAGE AND SEWAGE DRENA-LINE Residential Technology 1 HIGH QUALITY IS OUR MISSION The Pentair Group is one of the world leaders in the design and manufacture of innovative products and systems used

More information

Trusted Expertise in Domestic and Commercial Wastewater

Trusted Expertise in Domestic and Commercial Wastewater Trusted Expertise in Domestic and Commercial Wastewater Any Project, Any Wastewater Application Wastewater poses a complex challenge, no matter whether it originates in a single house or a multifamily

More information

Gira nurse call system Installation, start-up, operation. Gira emergency set

Gira nurse call system Installation, start-up, operation. Gira emergency set Gira nurse call system Installation, start-up, operation Gira emergency set 2914.. Table of Contents 1. Introduction... 4 1.1 General information... 4 1.2 Scope of delivery... 5 1.3 Area of application...

More information

Data sheet: Wilo-RainSystem AF Comfort MC 304

Data sheet: Wilo-RainSystem AF Comfort MC 304 Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater

More information

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data Instruction manual Submersible sump pump Safety instructions Application Electrical connection Installation Maintenance Technical data U 3 K /2 U 3 KS /2 U 3 K spezial /2 U 3 KS spezial /2 U 5 K /0 U 5

More information

LEAKSTOPPER 1 Single zone water leak detection system

LEAKSTOPPER 1 Single zone water leak detection system LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected

More information

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that

More information

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz GRUNDFOS PRODUCT GUIDE Submersible wastewater pumps 60 Hz Contents Mission Product overview, Unilift General data, Unilift Performance range 6 Applications 7 Type keys 8 Construction 9 Unilift CC Product

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

X1 series Submersible Drainage Pump

X1 series Submersible Drainage Pump X1 series Submersible Drainage Pump 50HZ STAIRS INDUSTRIAL CO., LTD. X1 SERIES - Submersible Pump Model code X1-03 M A - 32 Discharge size A =Float switch S =Vertical level switch M = Single Phase T =

More information

Alarm Switchgear AS1-M

Alarm Switchgear AS1-M Installation, Operating and Maintenance Instructions 1/7 Installation, Operating, and Maintenance Manual for Alarm Switchgear AS1-M These installation, operating and maintenance manual must be handed to

More information

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation. Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm Ground Water (DMS-298) Installation & Operating Manual Pump Station High Level Alarm T. E. W. 01992 523 523 info@deltamembranes.com www.deltamembranes.com Delta House, Merlin Way, North Weald, Epping,

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks

More information

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Model Number Structure

Model Number Structure Element Burnout Detector Accurate Detection of Element Burnout Regardless of Capacities Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs

More information

The easy solution for waste water removal

The easy solution for waste water removal The easy solution for waste water removal Wasteflo products provide a solution for waste water removal in a variety of environments. Full technical data sheets are available to download www.stuart-turner.co.uk

More information

NEWS 2017 SANIFLO. Pumps and pumping stations

NEWS 2017 SANIFLO. Pumps and pumping stations NEWS 2017 SANIFLO Pumps and pumping stations SFA, WORLD LEADER IN SANITARY FACILITIES MADE IN FRANCE For 60 years, the Société Française d Assainissement [French Sanitation Company] has worked on improving

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,

More information

POWER and INTELLIGENCE

POWER and INTELLIGENCE POWER and INTELLIGENCE Lifting stations The new lifting station Aqualift F Compact - Sewage lifting station complete basement drainage installation in a slab/floor and free-standing installation Leading

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe Stancor Duplex Oil-Minder System Submittal SE-100 115 Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe Solid State, NEMA 4x Duplex Oil-Minder Control The Stancor Duplex Oil-Minder

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

SUPPLEMENTARY INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate

More information

Instruction Manual. Electronic gas and smoke detector GRM

Instruction Manual. Electronic gas and smoke detector GRM Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon +49(0)7135-102-0 Service +49(0)7135-102-211 Telefax +49(0)7135-102-147 E-Mail

More information

MANUAL Oil Level Sensor

MANUAL Oil Level Sensor PROCESS AUTOMATION MANUAL Oil Level Sensor KVF-104-PF ISO9001 0102 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy

More information

CRU 200 and 500 Series Condensate Recovery Units

CRU 200 and 500 Series Condensate Recovery Units Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Choosing the Right Pump

Choosing the Right Pump Choosing the Right Pump Pumps are used to move fluid from one destination to another. They come in many different shapes, sizes, and operated by either electric motor, engine, by hand or solar power. They

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

KSB mechanical seals for water and waste water applications

KSB mechanical seals for water and waste water applications Our technology. Your success. Pumps n Valves n Service KSB mechanical seals for water and waste water applications 02 Introduction Single-source supplier: your partner for pumps, valves and service We

More information

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental

More information

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description Loop Detector is used to detect metal objects such as motor vehicles, motor bikes or trucks. ELSEMA Features Wide supply range: 12.0 to 24 Volts DC 16.0 to 24 Volts AC Selectable sensitivity Pulse or Presence

More information

INFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings.

INFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings. INFO 3/2015 www.alcaplast.com S WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings WC CONNECTORS flexible cuff to connect the outlet and WC pans

More information

WISY. Rainwater Harvesting. Installation and Operating Instructions. English. instructions for the. rainwater units. these installation

WISY. Rainwater Harvesting. Installation and Operating Instructions. English. instructions for the. rainwater units. these installation ion Instructions Installation Instructions Installation I English ons Installation Instructions Installation Instructions ion Instructions Installation Instructions Installation I ons Installation Instructions

More information

SECTION HEATING BOILER FEEDWATER EQUIPMENT

SECTION HEATING BOILER FEEDWATER EQUIPMENT SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American

More information

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC USER MANUAL Version 1.0 Doc. T744.01_EN (TEMP) TVHET916A07BK IMPORTANT READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity

More information

Operating instructions. Emergency system set. Ref.-No.: NRS Safety instructions. 2. System overview

Operating instructions. Emergency system set. Ref.-No.: NRS Safety instructions. 2. System overview Operating instructions 1. Safety instructions Electrical equipment must be installed and fitted only by qualified electricians and in observance of the current accident prevention regulations. Non-observance

More information

USER S MANUAL DN-2. Drain pump

USER S MANUAL DN-2. Drain pump USER S MANUAL DN-2 CONTENTS Safety requirements... 2 Purpose... 3 Delivery set... 3 Technical data... 3 Design... 4 Installation and set-up... 5 Connection to power mains... 8 Storage and transportation

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109 LST Digital Interface Monitor Module (LST-DiMM) MAN3109 TABLE OF CONTENTS: Page No. 1 Important Guidelines... 3 2 General Description... 4 Digital Interface Monitor Module... 4 3 Specifications... 5 Leader

More information

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC USER MANUAL Version 1.2 US Doc. T646.01 TVHET916A06 IMPORTANT READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

DATASHEET. Burner control unit FDA 601x

DATASHEET. Burner control unit FDA 601x EN 298 / EN 230 2012 19 PCB 100x160mm 3HE/8TE socket DIN 41612 2-channel microprocessor controlled program air valve control for heating / cooling preventilation continuous operation with ionisation intermittent

More information

This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS).

This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS). Introduction This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS). The Purpose of the ETS is to deliver chilled

More information

Conductivity Electrode LRG Original Installation Instructions English

Conductivity Electrode LRG Original Installation Instructions English Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards

More information

Protecting you and your home

Protecting you and your home Gira smoke alarm device Dual Q Dual Q sounds the alarm when dangerous smoke formation is detected and fulfils the increased Q-Label quality requirements. Dual Q is a combined heat and smoke detector, thanks

More information

VDS2510 Installation Manual

VDS2510 Installation Manual Video Signal Output No. 1 C N.C Output VDS2510 Installation Manual C N.C Output Viewer 2510-L (Local Unit) Video Signal Output OUTPUT Connections There are two VIDEO OUT connectors. Please connect each

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL

More information

Installation instructions Danfoss heat pump DHP-R

Installation instructions Danfoss heat pump DHP-R Installation instructions Danfoss heat pump DHP-R Table of contents DHP-R 1 Important information........................................................... 5 1.1 Refrigerant...5 1.2 Noise and vibrations...5

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Micro/Ultra Filtration System StamoClean CAT 430

Micro/Ultra Filtration System StamoClean CAT 430 Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater

More information

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and

More information

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II Installation and application Leakage detectors, CLS/FLS/FLS/MiniCAS II INTRODUCTION A number of condition monitoring sensors are available for the ITT FLYGT pump range. Thermal switches for stator over

More information

RQE Series Temperature Controllers

RQE Series Temperature Controllers RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature

More information

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No: PUDDLE PUMP PUDDLE PUMP MODEL No: PSP125 Part No: 7230692 OPERATION & MAINTENANCE INSTRUCTIONS 1007 SPECIFICATIONS Model number... PSP125 Rated voltage... 230VAC 50Hz Input power... 293 Watts Maximum delivery

More information

Submersible Pumps. New Style Submersible Pumps. With closed-loop cooling system. Non-Clogging Type CNX Series

Submersible Pumps. New Style Submersible Pumps. With closed-loop cooling system. Non-Clogging Type CNX Series Submersible Pumps Non-Clogging Type CNX Series With closed-loop cooling system High efficiency over a wider range New Style Submersible Pumps High efficiency over a wider range Development of 3 types (High,

More information

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra CI/SfB (57.7) 2nd edition Lo-Carbon Quadra Vent-Axia Quadra An Evolution in Residential Ventilation, Designed especially for Social Housing One fan fits all Happy Installers The fan that fits anywhere,

More information

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN CENTRIFUGAL CEILING EXTRACT FAN 110 Т/H/IR 110 Light Т/H/IR 150 Т/H/IR 150 Light Т/H/IR EN USER'S MANUAL CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery Set... 4 Designation key...

More information

8.0 Table of Contents. Monitoring system WIREM

8.0 Table of Contents. Monitoring system WIREM Table of Contents 8.0 8.0 Table of Contents 8.1 System description 8.100 General system description 8.110 Principle of operation 8.120 Measurement principle 8.2 Planning, inspection plans 8.200 Planning,

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

grundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate

grundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate grundfos SEG AUTOadapt SEG AUTOadapt range The perfect grinder pump for wastewater transport be think innovate Designed for dependability, efficiency and cost-effectiveness AUTOadapt sets new standards

More information

XP95 Sounder VAD Base

XP95 Sounder VAD Base PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm

More information

XC10 Extinguishing control panels

XC10 Extinguishing control panels XC10 Extinguishing control panels Market package 2.1 Advanced control panels for detection and alarming as well as for the activation of the extinguishing process Microprocessor-controlled fire detection

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

NON-SUBMERSIBLE WATER PUMP

NON-SUBMERSIBLE WATER PUMP NON-SUBMERSIBLE WATER PUMP MODEL NO: CEB103 PART NO: 7230327 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Water Pump, which is a general purpose pump, suitable

More information