SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Size: px
Start display at page:

Download "SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions."

Transcription

1 SM/SV Series PRODUCT COOLERS Technical Bulletin Products that provide lasting solutions.

2 Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse Coolers or Freezers to Fit a Wide Range of Capacities n Ruggedly constructed fan cabinet hung by hanger rods from the ceiling. n Efficient air drawthru design with 30" diameter aluminum fans for uniform air distribution; air throw is approximately 50 to 60 feet. n High efficiency three phase, 850 RPM fan motors are permanently lubricated. n Air defrost for medium temperature rooms. n Electric or hot gas defrost for medium and low temperature rooms. n Adjustable defrost termination and fan delay thermostat installed with electric defrost. n Bypass tee installed with hot gas defrost. Check valve provided shipped loose. n Mill galvanized drain pan and fan cabinet. n Drain pan is insulated for electric or hot gas defrost applications. n Drain pan and fan cabinet end panels are hinged for easy access and cleaning. n 4, 5, 6, and 7 fins per inch spacing. n Coated, corrosionresistant wire fan guards. n Compartmental fan sections. n 3phase, ball bearing motors 230/460V or 575V. n Suction Schrader valve for easy suction pressure/temperature measurement. Optional Features n Stainless steel housing and drain pan. n Brine and heat reclaim circuiting. n Insulated drain pan cover for air defrost models. n ElectroFin/Heresite coated coil for air defrost models. n Painted housing. Optional Accessories n Long throw air boosters (air throw approx. 100 feet). n Room thermostat. n Thermostatic expansion valve. n Defrost time clock. n Liquid line solenoid valve. n Suction liquid heat exchanger. n Remote located electrical control panel. SV SERIES Designed to Deliver Low Temperature Air at ExtraHigh Velocity in Freezers n Ruggedly constructed fan cabinet hung by hanger rods from the ceiling. n Wide capacity range. n Efficient air drawthru design with 30" diameter aluminum fans for uniform air distribution; air throw is approximately 60 to 80 feet. n High efficiency three phase, 1140 RPM fan motors are permanently lubricated. n Electric or hot gas defrost for low temperature rooms. n Adjustable defrost termination and fan delay thermostat installed. n Mill galvanized drain pan and fan cabinet. n Insulated drain pan. n Drain pan and fan cabinet end panels are hinged for easy access and cleaning. n 4, 5, and 6 fins per inch spacing. n Coated, corrosionresistant wire fan guards. n Compartmental fan sections. n 3phase, ball bearing motors 230/460V or 575V. n Suction Schrader valve for easy suction pressure/ temperature measurement. Optional Features n Stainless steel housing and drain pan. n ElectroFin/Heresite coated coil for hot gas defrost models. n Painted housing. Optional Accessories n Long throw air boosters (air throw approx. 120 feet). n Room thermostat. n Thermostatic expansion valve. n Defrost time clock. n Liquid line solenoid valve. n Suction liquid heat exchanger. n Remote located electrical control panel. n Copper tins. SM/SV SERIES PRODUCT COOLER 1

3 Ordering Information Specify When Ordering All Models n Complete model number. n Liquid refrigerant temperature. n Refrigerant R22, R404A, or R507. n 230/3, 460/3 or 575/3 motor and heater voltage. n Room temperature. n Optional features. n Saturated suction temperature. n Optional accessories. Model Key SM 2 5 E 842 C K K Heater Voltage Unit Type SM = Space Master SV = High Velocity SM K=208203/3/60 M= 460/3/60 P=575/3/60 U= 380/3/60 Number of Fans Motor Voltage Fin Spacing 4 FPI 5 FPI 6 FPI 7 FPI K=208203/3/60 M= 460/3/60 P=575/3/60 U= 380/3/60 Motor Type Type of Defrost C=3 Phase Motors A = Air B = Brine D = Electric with No Pan Heat E = Electric with Electric Pan G = 3 Pipe Hot Gas with Hot Gas Drain Pan H = 3 Pipe Hot Gas with Electric Drain Pan K = 2 Pipe Kool Gas with Kool Gas Drain Pan P = 2 Pipe Kool Gas with Electric Drain Pan R = Heat Reclaim U L C U L BTU/h in Hundreds (00) 2 SM/SV SERIES PRODUCT COOLERS

4 Air Defrost High Profile MODEL SM14A314 SM16A378 SM17A410 SM14A403 SM16A463 SM17A503 SM14A469 SM16A538 SM17A585 SM14A526 SM16A604 SM17A657 SM24A619 SM26A746 SM27A811 SM24A797 SM26A915 SM27A995 SM24A882 SM26A1063 SM27A1155 SM24A1038 SM26A1192 SM27A1296 SM34A1123 SM36A1289 SM37A1402 SM34A1243 SM36A1498 SM37A1628 SM34A1463 SM36A1678 SM37A1824 SM44A1532 SM46A1846 SM47A1920 SM44A1829 SM46A2204 SM47A2281 SM44A2015 SM46A2428 SM47A2581 CAPACITY TD 31,400 47,100 37,800 56,700 41,000 61,500 40,300 60,450 46,300 69,450 50,300 75,450 46,900 70,350 53,800 80,700 58,500 87,750 52,600 78,900 60,400 90,600 65,700 98,550 61,900 92,850 74, ,900 81, ,650 79, ,550 91, ,250 99, ,250 88, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,150 MEDIUM TEMPERATURE FAN MOTOR AMPS /3 460/3 575/3 AIR FLOW (CFM) 9,860 8,980 8,550 9,690 8,810 8,390 9,510 8,480 8,100 9,330 8,400 8,000 19,700 17,900 17,100 19,380 17,600 16,800 18,890 16,900 16,100 18,400 16,800 15,900 28,600 24,900 24,700 28,000 24,600 23,700 27,400 24,400 23,500 33,900 33,200 32,930 33,400 32,800 31,600 33,000 32,530 31, DIMENSIONS (IN) L W H SHIPPING WGT. (LBS) ,070 1,090 1,034 1,156 1,175 1,100 1,235 1,255 1,280 1,430 1,455 1,380 1,540 1,565 1,470 1,645 1,670 Capacity Ratings are based on sensible heat removal with a TEV fed, medium frosted coil when: Fan motor heat is not included in ratings add 4000 BTUH per fan to room load for SM units, or 6600 BTUH per fan to room load for SV units. Derate 12% for 50 Hertz (0.88 multiplier) or increase TD to compensate for lower fan RPM. SM/SV SERIES PRODUCT COOLERS 3

5 Electric Defrost High Profile MEDIUM TEMPERATURE CAPACITY 10 TD AIR FLOW FAN MOTOR AMPS SM MODEL SM14E384 SM15E426 SM16E440 SM14E501 SM15E556 SM16E574 SM24E759 SM25E842 SM26E869 SM24E989 SM25E1097 SM26E1132 SM34E1070 SM35E1186 SM36E1225 SM34E1393 SM35E1544 SM36E1594 SM44E1465 SM45E1523 SM46E1754 SM44E1769 SM45E SST 38,400 42,600 44,000 50,100 55,600 57,400 75,900 84,200 86,900 98, , , , , , , , , , , , , ,500 SST 40,300 44,700 46,300 52,600 58,400 60,400 79,700 88,400 91, , , , , , , , , , , , , , , ,800 (CFM) 9,690 9,250 8,810 9,330 8,900 8,400 19,380 18,500 17,600 18,400 17,600 16,800 28,600 27,300 24,900 27,400 26,100 25,800 38,130 36,400 33,200 36,530 34,800 32, / /3 575/3 SV MODEL Low Temperature Only Below +30 F SV14E422 SV15E468 SV16E664 SV14E550 SV15E611 SV24E834 SV25E926 SV26E1005 SV24E1088 SV25E1206 SV26E1311 SV34E1177 SV35E1304 SV36E1418 SV34E1530 SV35E1698 SV36E1843 SV44E1699 SV45E1883 SV46E2047 SV44E2052 SV45E2274 SV46E ,200 46,800 66,400 55,000 61,100 83,400 92, , , , , , , , , , , , , , , , ,200 11,250 11,125 11,000 11,250 11,125 24,225 23,125 22,800 23,000 22,000 21,550 35,750 34,125 33,400 34,250 32,625 32,000 47,650 45,500 44,500 45,650 43,600 42,700 DIMENSIONS (IN) L W H Capacity Ratings are based on sensible heat removal with a TEV fed, medium frosted coil when: Fan motor heat is not included in ratings add 4000 BTUH per fan to room load for SM units, or 6600 BTUH per fan to room load for SV units. Derate 12% for 50 Hertz (0.88 multiplier) or increase TD to compensate for lower fan RPM. Insulated drain pan standard on EDL models. Four fan SM/SV for low temperature requires two TEVs SHIPPING WGT. (LBS) ,030 1,050 1,060 1,195 1,215 1,240 1,370 1,340 1,400 1,469 1,540 1, ,030 1,050 1,060 1,195 1,215 1,240 1,370 1,340 1,400 1,469 1,540 1,600

6 Hot Gas Defrost High Profile LOW TEMPERATURE MODEL SM14( )384 SM15( )426 SM16( )440 SM14( )501 SM15( )556 SM16( )574 SM24( )759 SM25( )842 SM26( )869 SM24( )989 SM25( )1097 SM26( )1132 SM34( )1070 SM35( )1186 SM36( )1225 SM34( )1393 SM35( )1544 SM36( )1594 SM44( )1465 SM45( )1523 SM46( )1754 SM44( )1769 SM45( )1985 SM46( )2307 CAP. 10 TD 20 SST 38,400 42,600 44,000 50,100 55,600 57,400 75,900 84,200 86,900 98, , , , , , , , , , , , , , , SST 40,300 44,700 46,300 52,600 58,400 60,400 79,700 88,400 91, , , , , , , , , , , , , , , ,800 AIR FLOW (CFM) 9,690 9,250 8,810 9,330 8,900 8,400 19,380 18,500 17,600 18,400 17,600 16,800 28,600 27,300 24,900 27,400 26,100 25,800 38,130 36,400 33,200 36,530 34,800 32,530 FAN MOTOR AMPS /3 460/3 575/ DIMENSIONS (IN) L W H SHIPPING WGT. (LBS) ,030 1,050 1,060 1,195 1,215 1,240 1,370 1,340 1,400 1,469 1,540 1,600 NOTE: *Available Types of Defrost: (P) KGE 2 Pipe Kool Gas with Electric Pan, (K) KGG 2 Pipe Kool Gas with Kool Gas Pan, (H) HGE 3 Pipe Hot Gas with Electric Pan, (G) HGG 3 Pipe Hot Gas with Hot Gas Pan. NOTE: 4 Fans SM/SV for low temp requires 2 TEVs. SM/SV SERIES PRODUCT COOLERS 5

7 Electric Defrost Heater Data MODEL 1 FAN 384, 426, FAN 501, 556, FAN 759, 842, 869, 989, 1097, FAN 1070, 1186, FAN 1393, 1544, FAN 1465, 1523, FAN 1769, 1985, 2307 COIL ONLY D 230/3* 460/3 575/3 AMPS KW AMPS KW AMPS @42.2 1@10.6 1@40.7 1@13.5 1@40.7 1@ @ 1@4.2 1@ 1@5.4 1@16.2 1@ NOTE: Electric Defrost data shown as one circuit AMP draw, unless shown with two circuits (1@ and 1@) or three circuits (2@ and 1@) in the same space KW MODEL 1 FAN 384, 426, 440, 501, 556, FAN 422, 468, 550, 611, FAN 759, 842, 869, 989, 1097, FAN 834, 926, 1005, 1088, 1206, 1311 COIL AND PAN E 230/3* 460/3 AMPS KW AMPS @42.2 1@ @ 1@ KW /3 AMPS KW FAN 1070, 1186, 1225, 1177, 1304, FAN 1393, 1544, 1594, 1530, 1698, @42.2 1@32.5 1@ 1@ FAN 1465, 1523, 1754, 1699, 1883, FAN 1769, 1985, 2307, 2052, 2274, @40.7 1@14.3 2@16.2 1@ NOTE: Electric Defrost data shown as one circuit AMP draw, unless shown with two circuits (1@ and 1@) or three circuits (2@ and 1@) in the same space. MODEL 1 FAN 384, 426, 440, 501, 556, 574, 550, 611, FAN 759, 842, 869, 989, 1097, 1132, 834, 926, 1005, 1088, 1206, FAN 1070, 1186, 1225, 1177, 1304, , 1544, 1594, 1530, 1698, FAN 1465, 1523, 1754, 1699, 1883, , 1985, 2307, 2052, 2274, 2472 PAN ONLY H AND P 230/3* 460/3 AMPS KW AMPS KW /3 AMPS KW NOTE: Electric Defrost data shown as one circuit AMP draw, unless shown with two circuits (1@ and 1@) or three circuits (2@ and 1@) in the same space. 6 SM/SV SERIES PRODUCT COOLERS

8 Installation Data SM MEDIUM TEMPERATURE ROOM AIR DEFROST 4 FINS PER INCH 6 FINS PER INCH 7 FINS PER INCH 10 F TD REFRIG. 10 F TD REFRIG. 10 F TD +20 F SST +20 F SST +20 F SST CHARGE MODEL SUCT. ODS (LBS) MODEL SUCT. ODS (LBS) MODEL SUCT. ODS (LBS) SM14* SM14* SM14* SM14* SM24* SM24* SM24* SM24* SM34* SM34* SM34* SM44* SM44* SM44* SM16* SM16* SM16* SM16* SM26* SM26* SM26* SM26* SM36* SM36* SM36*167A SM46* SM46* SM46* SM LOW TEMPERATURE ROOM ELECTRIC OR HOT GAS DEFROST SM17* SM17* SM17* SM17* SM27* SM27* SM27* SM27* SM37* SM37* SM37* SM47* SM47* SM47* * A, B, or R. 4 FINS PER +20 F SST F,G,H,K,M,P, CHARGE SM14** SM14** SM24** SM24** SM34** SM34** SM44** x x SM44** x x FINS PER +20 F SST F,G,H,K,M,P, CHARGE SM15** SM15** SM25** SM25** SM35** SM35** SM45** x x SM45** x x FINS PER +20 F SST F,G,H,K,M,P, CHARGE SM16** SM16** SM26** SM26** SM36** SM36** SM46** x x SM46** x x FINS PER INCH SV LOW TEMPERATURE ROOM ELECTRIC OR HOT GAS DEFROST 5 FINS PER INCH 6 FINS PER 20 F SST F,G,H,K,M,P, CHARGE SV14E SV14E SV24E SV24E SV34E SV34E SV44E x x SV44E x x F SST F,G,H,K,M,P, CHARGE SV15E SV15E SV15E SV25E SV25E SV35E SV35E x x SV45E x x F SST F,G,H,K,M,P, CHARGE SV16E SV16E SV16E SV26E SV26E SV36E SV36E x x SV46E x x "2x" indicates two connections per unit. ** B, D, E, G, H, K, P, or R. SM/SV SERIES PRODUCT COOLERS 7

9 Wiring Diagrams A, B, G, K, or R DEFROST H DEFROST (THREE PIPE HOT GAS DEFROST WITH ELECTRIC DRAIN PAN) P DEFROST (TWO PIPE KOOLGAS DEFROST WITH ELECTRIC DRAIN PAN) D or E DEFROST (ELECTRIC DEFROST) Common Replacement Parts SM SERIES PART PART # MOTOR 230/460V MOTOR 575V FAN BLADE FAN GUARD AIR BOOSTER DEFROST TERMINATION FAN DELAY TSTAT SV SERIES PART PART # MOTOR 230/460V MOTOR 575V FAN BLADE FAN GUARD AIR BOOSTER DEFROST TERMINATION FAN DELAY TSTAT SM/SV SERIES PRODUCT COOLERS

10 Dimensional Data UNIT DIMENSIONS SIZE A B C D E 1 FAN @ FAN 11 2@ FAN 11 3@ FAN 15 4@ Note: Dimensions in inches. SM/SV SERIES PRODUCT COOLERS 9

11 Krack Corporation 1300 North Arlington Heights Rd., Suite 130 Itasca, IL Ph: krack.com Printed in U.S.A Krack Corporation SM/SV_K_082012

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for

More information

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions. MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions. H and GH/G Series UNIT COOERS Technical Bulletin: HGH_00_0 Products that provide lasting solutions. H and GH/G SERIES UNIT COOERS H Series Unit Coolers Dual Discharge ow Hite Series At 9 / maximum height,

More information

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions. KR Series COMPACT UNIT COOERS Technical Bulletin: KRUC_00_07 Products that provide lasting solutions. Provides Excellent Design Innovations That Enhance Overall Refrigeration Performance The KR Compact

More information

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature

More information

SM/SV-Space Master Unit Coolers (E R.0)

SM/SV-Space Master Unit Coolers (E R.0) SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008 R.0) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING

More information

Low Profile Unit Coolers

Low Profile Unit Coolers CH-LOPTB MAR 2015 Replaces CH-LOPTB JAN 2015 Low Profile Unit Coolers Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost Table of Contents Nomenclature 2 Features & Benefits

More information

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May, CH-LOPTB May, 2008 Replaces CH-B-15B, March 2004y 2007 LOW PROFILE UNIT COOLER Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost www.chandlerref.com Table of Contents Nomenclature...2

More information

SM/SV Series Space Master Unit Coolers Operating and Installation Manual

SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008_G) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING

More information

Low Profile Unit Coolers

Low Profile Unit Coolers BN-LOPTB AUGUST 2018 Replaces BN-LOPTB APRIL 2018 Low Profile Unit Coolers Technical Guide s ADT LET/LLE HGT Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...

More information

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability- A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job

More information

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost. LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600

More information

Slim Contour Unit Cooler

Slim Contour Unit Cooler Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016 ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim

More information

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

Low Flow Unit Coolers

Low Flow Unit Coolers BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3

More information

KTL Two-Way Low Profile Evaporators

KTL Two-Way Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin K30--PDI-16 Part # 87830 PRODUCT SUPPORT web: k-rp.com/ktl email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Two-Way Low Profile Evaporators High, Medium and Low

More information

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL

More information

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications) Levitor II AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications) Technical Bulletin: LEVE_002_103116 Products that provide lasting solutions. Table

More information

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Compak Unit Coolers LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost 3,500 to 27,000 BTU/H Front access to refrigeration components. Now

More information

BTL Two-Way Low Profile Evaporators

BTL Two-Way Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature

More information

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost. bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features

More information

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular

More information

KTL Two-Way Low Profile Unit Coolers

KTL Two-Way Low Profile Unit Coolers PRODUCT DATA & INSTALLATION Bulletin K30-KTL-PDI-2 1087830 KTL Two-Way Low Profile Unit Coolers High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical

More information

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant

More information

KR Electrical Defrost Unit Coolers (PN E108318_E)

KR Electrical Defrost Unit Coolers (PN E108318_E) KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN

More information

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5 ` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single

More information

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3

More information

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide BN-HGDTB June 2017 Replaces BN-HGDTB, March 2011 Mohave Technical Guide Table of Contents Overview... 2 System Features... 3 Condensing Unit... 4-18 Mohave Hot Gas Defrost Quick Reference... 5 AWEF Ratings...11

More information

Air-Cooled Condensers

Air-Cooled Condensers CH-RACCTB APR 2015 Replaces CH-RACCTB April 2011 Air-Cooled Condensers Technical Guide Models WSS Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional Data...5

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products PRUCT CATALOG Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products peerlessofamerica.com Welcome to Peerless of America II Peerless of America II Inc. was founded in 1912

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Industrial Unit Coolers

Industrial Unit Coolers HC.CH-IUC l March 2016 Industrial Unit Coolers Sales Brochure We Know Cold Storage Heatcraft Worldwide Refrigeration announces its latest addition of large capacity unit coolers for the Cold Storage and

More information

KR Series Air Defrost Unit Coolers Operating and Installation Manual

KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Air Defrost Unit Coolers (PN E108317_L) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT... 2 1.1 INSPECTION... 2 1.2 LOSS OF GAS HOLDING

More information

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018 ` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

TLV Low Velocity Evaporators

TLV Low Velocity Evaporators PRODUCT DATA & INSTALLATION Bulletin T30-TLV-PDI-27 Part # 1073478 PRODUCT SUPPORT web: t-rp.com/tlv email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: TLV Low Velocity Evaporators High Temperature

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

STC Series Twin Unit Coolers (E329630_A)

STC Series Twin Unit Coolers (E329630_A) STC Series Twin Unit Coolers Operating and Installation Manual STC Series Twin Unit Coolers (E329630_A) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING CHARGE 3 2 ASSEMBLY

More information

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5 ` RLP 1-2019C Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed

More information

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 ` RLP 7-2018A Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless

More information

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV Table of Contents Nomenclature Chart... 2 Features and Benefits...3

More information

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00 BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Refrigeration Systems by. Cool You Can Count On!

Refrigeration Systems by. Cool You Can Count On! Refrigeration Systems by Cool You Can Count On! www.ref-sys.com Keeping Storage Cool... Refrigeration Systems (RSI) has provided engineered cooling systems to agricultural refrigeration markets and vegetable

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

SMALL AIR COOLED CONDENSERS

SMALL AIR COOLED CONDENSERS Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of

More information

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

KCC Centrifugal Fan Air Cooled Condensers

KCC Centrifugal Fan Air Cooled Condensers PRODUCT DATA & INSTALLATION Bulletin K50-KCC-PDI-10 KCC Centrifugal Fan Air Cooled Condensers Air Cooled Models from 103 Thru 164 Four to ninety Ton 1064435 We are on the Internet www.keepriterefrigeration.com

More information

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES ` RLP 1-2019 Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Evaporators 60HZ version

Evaporators 60HZ version Innovative Engineering Catalogue Evaporators 60HZ version Heat Exchangers Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms Humidity controled cold rooms Air conditioning Refrigerated

More information

DT/DTX Series Unit Coolers (R0 E316013)

DT/DTX Series Unit Coolers (R0 E316013) DT/DTX Series Unit Coolers Operating and Installation Manual DT/DTX Series Unit Coolers (R0 E316013) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING CHARGE 3 2 ASSEMBLY

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

HEATING & COOLING COIL PRODUCTS

HEATING & COOLING COIL PRODUCTS HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

commercial refrigeration products

commercial refrigeration products commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz) Innovative Engineering Catalogue Evaporators EKL1. Extra low temperature applications (60 Hz) Heat Exchangers www.eka-kool.com Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms

More information

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls Ultimate Comfortable Energy saving product Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls With intelligent temp. & humidity controller adjustable temperature control

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM Eaton-Williams Ltd APPLICATION MANUAL ICC COOLING STORAGE UNIT ICC/ICU SYSTEM Eaton-Williams Ltd Station Road Edenbridge Kent TN8 6EG Tel: +44 (0)1732 866066 Fax +44(0)1732 866653 www.eaton-williams.com

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Air-Cooled Condensers

Air-Cooled Condensers BN-RACCTB Sept. 2016 Replaces BN-RACCTB April 2015 Air-Cooled Condensers Technical Guide Models DVT Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional

More information

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LIST PRICES SEE THE BACK COVER FOR CONDITIONS OF SALE AND WARRANTY BULLETIN KLP 7-2018A Supersedes All KRAMER Price Lists Published Prior To July 2018 July, 2018 LIST PRICES Prices effective 7/2/18 Add appropriate expansion valve price(s) from page 13 of this price sheet

More information

ThermoSaver TM Hot Gas Defrost System

ThermoSaver TM Hot Gas Defrost System PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin K40-THERM-PDI-15 Part # 1069130 PRODUCT SUPPORT web: k-rp.com/ts email: mdcu-lgcu@k-rp.com

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions 38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER SERIES LPA SERIES LPE SERIES LPG SERIES LPH AIR DEFROST APPLICATION ELECTRIC DEFROST APPLICATION

More information

LOW PROFILE EVAPORATORS

LOW PROFILE EVAPORATORS PS SERIES & PSL SERIES LOW PROFILE EVAPORATORS MEDIUM & LOW TEMPERATURE EVAPORATORS ORIGINAL MANUFACTURED EQUIPMENT PS Series PSL Series HX-404-3 AUS Product Specifications The PS Series Low Line Evaporators

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

RDT Refrigeration Book

RDT Refrigeration Book RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.

More information

LK-PL Jan Price List

LK-PL Jan Price List LK-PL Jan. 2018 Price List Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

Price List. BN-PL Oct. 2017

Price List. BN-PL Oct. 2017 Price BN-PL Oct. 2017 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler See page

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information