We are pleased to submit the following equipment for your approval on the above project:

Size: px
Start display at page:

Download "We are pleased to submit the following equipment for your approval on the above project:"

Transcription

1 Sigler Southern California 205 S. Puente St. Brea, CA PH: Salesman: Tim Dres SUBMITTAL DATA PROJECT: LAUSD South Region High School 15 MECHANICAL CONTRACTOR: Mechanical Technology Systems Attn: Russ We are pleased to submit the following equipment for your approval on the above project: Mark For Qty Model Number Description PAC-A1 1 48A2M020-AC611HJ 20 Ton Gas Heat Packaged Unit w/ R-410a Stainless Steel Drain Pan Dry-Bulb Economizer Modulating Power Exhaust CV Vertical ComfortLink w/puron Low Gas Heat S.S. Heat Exch High Efficiency 5 HP Motor Cu/Cu Cond, Cu/Cu Evap PAC- 3 48TCSD14A2F6-0A0A Ton Gas Heat Packaged Unit w/ R-410a A2,B1,B3 Stainless Steel, Low Heat HX Medium Static Option Cu/Cu - Cu/Cu Hinged Access Panels PAC- 3 CRFLUEDS001A00 Flue Discharge Deflector A2,B1,B3 PAC MA930 Mod. Power Exhaust/Economizer A2,B1,B3 PAC-B2,D3, 5 48HCSA07A2F6-0A3A0 6 Ton High Eff. Gas Heat Packaged Unit w/ R-410a D6,E7,F7 Stainless Steel, Low Heat HX Medium Static Option - Belt Drive Cu/Cu - Cu/Cu Hinged Access Panels PAC-B2,D3, 5 CRFLUEDS001A00 Flue Discharge Deflector D6,E7,F7 PAC-D /2-MA930 Mod. Power Exhaust/Economizer PAC-B2,D6, HJ712DBEC DOWN DISCHARGE FIXED DRY BULB ECONOMIZER E7,F7 PAC-C1,C2 2 48A2M035-DC611HJ 35 Ton Gas Heat Packaged Unit w/ R-410a Stainless Steel Drain Pan Dry-Bulb Economizer Modulating Power Exhaust CV Vertical ComfortLink w/puron Low Gas Heat S.S. Heat Exch High Efficiency 15 HP Motor Cu/Cu Cond, Cu/Cu Evap PAC-C3,C4, 5 48HCSD08A2F6-0A3A0 7.5 Ton High Eff. Gas Heat Packaged Unit w/ R-410a D2,E8,F8 Stainless Steel, Low Heat HX Medium Static Option - Belt Drive Cu/Cu - Cu/Cu Electro-mechanical controls Hinged Access Panels

2 PAC-C3,C4, 5 CRFLUEDS001A00 Flue Discharge Deflector D2,E8,F8 PAC-C3,C4, MA930 Mod. Power Exhaust/Economizer D2,E8,F8 PAC-D1 1 48A4M020-AC611EF 20 Ton Gas Heat Packaged Unit w/ R-410a Stainless Steel Drain Pan Dry-Bulb Economizer CV Horizontal ComfortLink w/puron Low Gas Heat S.S. Heat Exch High Efficiency 5 HP Motor Cu/Cu Cond, Cu/Cu Evap PAC-D MA910 Modulating Power Exhaust PAC-D4,D5, 12 48HCLA05A2F6-0A3A0 4 Ton High Eff. Gas Heat Packaged Unit w/ R-410a E1-5,F1-5 Low NOx, Low Heat Medium Static Option - Belt Drive Cu/Cu - Cu/Cu Hinged Access Panels PAC-D4,D5, 12 CRFLUEDS001A00 Flue Discharge Deflector E1-5,F1-5 PAC-D4,D5, HJ36DBEC DOWN DISCHARGE FIXED DRY BULB ECONOMIZER E1-5,F1-5 PAC-E6,F6 2 48HCLA06A2F6-0A3A0 5 Ton High Eff. Gas Heat Packaged Unit w/ R-410a Low NOx, Low Heat Medium Static Option - Belt Drive Cu/Cu - Cu/Cu Hinged Access Panels PAC-E6,F6 2 CRFLUEDS001A00 Flue Discharge Deflector PAC-E6,F HJ36DBEC DOWN DISCHARGE FIXED DRY BULB ECONOMIZER FCU-2 Ton 14 24HBX0-120-W/R410ATXV 2 Ton First Co Modular AHU 115V - Coated Coil CU-2 Ton 14 24ABB324C003 2 Ton Air Conditioner w/ R-410a and Coastal Option FCU-3 Ton 6 36HBX0-120-W/R410ATXV 3 Ton First Co Modular AHU 115V - Coated Coil CU-3 Ton 6 24ABB336C003 3 Ton Air Conditioner w/ R-410a and Coastal Option CU-B1-3,4 2 38AUQA12A0C6-0A0A0 10 Ton Heat Pump w/ R-410a Factory E-Coated Al/Cu Coil CU-C1-5,6 2 24ABB360C003 5 Ton Air Conditioner w/ R-410a and Coastal Option FCU-2 Ton 14 24VHBX0-120-W/R410ATXV 2 Ton First Co Modular AHU 115V - Coated Coil HP-2 Ton 14 25HBB324C003 2 Ton Heat Pump w/ R-410a and Coastal Option FCU-3 Ton 2 36VHBX0-120-W/R410ATXV 3 Ton First Co Modular AHU 115V - Coated Coil HP-3 Ton 2 25HBB336C003 3 Ton Heat Pump w/ R-410a and Coastal Option FCU-4 Ton 8 60VHBX0-120-W/R410ATXV 4,5 Ton First Co Modular AHU 115V - Coated Coil HP-4 Ton 8 25HBB348C003 4 Ton Heat Pump w/ R-410a and Coastal Option HP-E AUQA08A0C6-0A0A0 7.5 Ton Heat Pump w/ R-410a and F1-5 Factory E-Coated Al/Cu Coil HP-E RUQA08A1A6-0A0A0 7.5 Ton Heat Pump Air Handler 208/230/ Coated Coil and F1-5 ALL FCUs 46 BLYGOLDEVAPCOAT Blygold Evap Coatings - All Fan Coil NOTE: A COPY OF THIS SUBMITTAL MUST BE RETURNED MARKED APPROVED OR APPROVED AS NOTED PRIOR TO OUR ENTERING FACTORY ORDER. Carrier of Southern California, Inc. August 5, 2010

3 Performance Summary For PAC-A1 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number: 48A2M020-AC611HJ Unit Refrigerant: R410A EER (ARI 360): 10.1 IEER: 11.4 Shipping Dimensions Unit Length: 13' 9'' Unit Width: 7' 10'' Unit Height: 6' 1'' Unit Shipping Weight: lb Unit Supply/Return: Vertical/Vertical Application Type: CV 2-stage Voltage: Cooling Airflow: 6000 CFM Altitude: 0 ft Cond. Ent. Air Temp: 94.0 F Ent. Air Dry Bulb: 82.6 F Ent. Air Wet Bulb: 66.5 F Ent. Air Enthalpy: BTU/lb Lvg. Air Dry Bulb: 55.1 F Lvg. Air Wet Bulb: 53.2 F Lvg. Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Clg. Cap: MBH Compressor Power: 18.0 kw Coil Bypass Factor: 0.17 Part Load(%) Operation Standard Capacity Steps: 30,100 Gas Heating Data: Heating Airflow: 6000 CFM Heating Ent. Air Temp: 52.6 F Gas Input (Min): MBH Gas Input (Max): 350 MBH Gas Output: 287 MBH Heating Lvg. Air Temp: 96.9 F Steady State Eff: 82 Temp.Rise: 44.3 F Supply Fan Information: Ext.Static Pressure: 2.50 in wg Selection External Static Pressure: 2.50 in wg Supply Fan RPM: 909 Supply Fan BHP: 4.62 BHP Supply Fan Motor HP: 05 HP Power Exhaust Fan Information: P.E./R.F. Airflow: 4200 CFM P.E./R.F. Ext. Static: 0.50 in wg P.E./R.F. Tot. Static: 1.14 in wg Electrical Data Minimum Voltage: 414 Maximum Voltage: 508 Compressor #A1 RLA: 10.6 Compressor #A1 LRA: 75 Compressor #A2 RLA: 10.6 Compressor #A2 LRA: 75 Compressor #B1 RLA: 14.7 Compressor #B1 LRA: 95 Indoor Fan Motor HP: 5 Indoor Fan Motor FLA: 7.6 Condenser Fan Motor Qty: 2 Applied Rooftop Builder 2.09 Page 27 of 34

4 Performance Summary For PAC-C1,C2 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number: 48A2M035-DC611HJ Unit Refrigerant: R410A EER (ARI 360): 10.0 IEER: 11.8 Shipping Dimensions Unit Length: 13' 9'' Unit Width: 7' 10'' Unit Height: 6' 1'' Unit Shipping Weight: lb Unit Supply/Return: Vertical/Vertical Application Type: CV 2-stage Voltage: Cooling Airflow: CFM Altitude: 0 ft Cond. Ent. Air Temp: 94.0 F Ent. Air Dry Bulb: 76.8 F Ent. Air Wet Bulb: 68.8 F Ent. Air Enthalpy: BTU/lb Lvg. Air Dry Bulb: 58.0 F Lvg. Air Wet Bulb: 58.0 F Lvg. Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Clg. Cap: MBH Compressor Power: 30.9 kw Coil Bypass Factor: Part Load(%) Operation Standard Capacity Steps: 50,100 Gas Heating Data: Heating Airflow: CFM Heating Ent. Air Temp: 67.6 F Gas Input (Min): MBH Gas Input (Max): 350 MBH Gas Output: MBH Heating Lvg. Air Temp: 89.5 F Steady State Eff: 81 Temp.Rise: 21.9 F Supply Fan Information: Ext.Static Pressure: 1.25 in wg Selection External Static Pressure: 1.25 in wg Supply Fan RPM: 980 Supply Fan BHP: BHP Supply Fan Motor HP: 15 HP Power Exhaust Fan Information: P.E./R.F. Airflow: CFM P.E./R.F. Ext. Static: 0.50 in wg P.E./R.F. Tot. Static: 0.13 in wg Electrical Data Compressor #A1 RLA: 10.6 Compressor #A1 LRA: 75 Compressor #A2 RLA: 10.6 Compressor #A2 LRA: 75 Compressor #B1 RLA: 16.7 Compressor #B1 LRA: 114 Compressor #B2 RLA: 16.7 Compressor #B2 LRA: 114 Indoor Fan Motor HP: 15 Indoor Fan Motor FLA: 21 Condenser Fan Motor Qty: 2 Applied Rooftop Builder 2.09 Page 29 of 34

5 Base unit dimensions 48A2,A NOTES: 1. Weights include economizer. 2. center of gravity. 3. Unit clearances: Top of units: no overhang Condenser coil: 4-0 [1219] Economizer side: 6-0 [1829] Heat side: 4-0 [1219] Filter access side: 10-0 [3048] (for removal of evaporator coil) 4. For smaller service and operational clearances, contact Carrier application engineering department. 5. Bottom ducts are designed to be attached to accessory roof curb. If unit is mounted on dunnage, it is recommended that the ducts be supported by cross braces as done on accessory roof curb. 6. Dimensions in [ ] are in millimeters. All other dimensions are in inches. *Operating weight includes largest indoor fan motor, microchannel heat exchanger, modulating power exhaust (variable air volume units), and variable frequency drive (variable air volume units). a

6 Performance Summary For PAC-D1 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number: 48A4M020-AC611EF Unit Refrigerant: R410A EER (ARI 360): 10.1 IEER: 11.4 Shipping Dimensions Unit Length: 13' 9'' Unit Width: 7' 10'' Unit Height: 6' 1'' Unit Shipping Weight: lb Unit Supply/Return: Horizontal/Horizontal Application Type: CV 2-stage Voltage: Cooling Airflow: 6600 CFM Altitude: 0 ft Cond. Ent. Air Temp: 94.0 F Ent. Air Dry Bulb: 84.3 F Ent. Air Wet Bulb: 67.8 F Ent. Air Enthalpy: BTU/lb Lvg. Air Dry Bulb: 57.9 F Lvg. Air Wet Bulb: 55.7 F Lvg. Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Clg. Cap: MBH Compressor Power: 18.1 kw Coil Bypass Factor: Part Load(%) Operation Standard Capacity Steps: 30,100 Gas Heating Data: Heating Airflow: 6600 CFM Heating Ent. Air Temp: 41.0 F Gas Input (Min): MBH Gas Input (Max): 350 MBH Gas Output: 287 MBH Heating Lvg. Air Temp: 81.3 F Steady State Eff: 82 Temp.Rise: 40.3 F Supply Fan Information: Ext.Static Pressure: 1.50 in wg Selection External Static Pressure: 1.50 in wg Supply Fan RPM: 763 Supply Fan BHP: 4.12 BHP Supply Fan Motor HP: 05 HP Electrical Data Minimum Voltage: 414 Maximum Voltage: 508 Compressor #A1 RLA: 10.6 Compressor #A1 LRA: 75 Compressor #A2 RLA: 10.6 Compressor #A2 LRA: 75 Compressor #B1 RLA: 14.7 Compressor #B1 LRA: 95 Indoor Fan Motor HP: 5 Indoor Fan Motor FLA: 7.6 Condenser Fan Motor Qty: 2 Condenser Fan Motor FLA (ea): 3.3 Power Supply MCA: 53.8 Power Supply MOCP (Fuse or HACR): 60 Electrical Convenience Outlet: None Acoustic Information Applied Rooftop Builder 2.09 Page 31 of 34

7 Base unit dimensions 48A4,A NOTES: 1. Weights include economizer. 2. center of gravity. 3. Unit clearances: Top of units: no overhang Condenser coil: 4-0 [1219] Economizer side: 6-0 [1829] Heat side: 4-0 [1219] Filter access side: 10-0 [3048] (for removal of evaporator coil) 4. For smaller service and operational clearances, contact Carrier application engineering department. 5. Dimensions in [ ] are in millimeters. All other dimensions are in inches. *Operating weight includes largest indoor fan motor, microchannel heat exchanger, modulating power exhaust (variable air volume units), and variable frequency drive (variable air volume units). a

8

9 Performance Summary For PAC-A2 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48TCSD14A2F6-0A0A0 ARI EER: IEER: 11.0 Base Unit Weight: 1118 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 4250 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 80.3 F Evaporator Entering Air WB: 64.1 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 55.8 F Evaporator Leaving Air WB: 52.9 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: kw Coil Bypass Factor: Heating Performance Heating Airflow: 4250 CFM Entering Air Temp: 61.1 F Leaving Air Temp: 93.3 F Gas Input Capacity: / MBH Gas Heating Capacity: MBH Temperature Rise: 32.2 F NOTE: Second Stage Supply Fan External Static Pressure: 0.75 in wg Fan RPM: 963 Fan Power: 2.68 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Compressor #2 RLA: 10.6 Compressor #2 LRA: 75 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 3.1 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 4.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 30.5 Power Supply MOCP (Fuse or HACR): 40 Min. Unit Disconnect FLA: 32 Min. Unit Disconnect LRA: 190 Electrical Convenience Outlet: None Acoustics Packaged Rooftop Builder 1.20 Page 1 of 34

10 Performance Summary For PAC-B1 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48TCSD14A2F6-0A0A0 ARI EER: IEER: 11.0 Base Unit Weight: 1118 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 4250 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 82.1 F Evaporator Entering Air WB: 65.2 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 57.2 F Evaporator Leaving Air WB: 54.1 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: kw Coil Bypass Factor: Heating Performance Heating Airflow: 4250 CFM Entering Air Temp: 57.4 F Leaving Air Temp: 89.6 F Gas Input Capacity: / MBH Gas Heating Capacity: MBH Temperature Rise: 32.2 F NOTE: Second Stage Supply Fan External Static Pressure: 0.75 in wg Fan RPM: 963 Fan Power: 2.68 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Compressor #2 RLA: 10.6 Compressor #2 LRA: 75 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 3.1 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 4.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 30.5 Power Supply MOCP (Fuse or HACR): 40 Min. Unit Disconnect FLA: 32 Min. Unit Disconnect LRA: 190 Electrical Convenience Outlet: None Acoustics Packaged Rooftop Builder 1.20 Page 3 of 34

11 Performance Summary For PAC-B3 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48TCSD14A2F6-0A0A0 ARI EER: IEER: 11.0 Base Unit Weight: 1118 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 3900 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 75.6 F Evaporator Entering Air WB: 63.6 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 53.2 F Evaporator Leaving Air WB: 51.4 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: kw Coil Bypass Factor: Heating Performance Heating Airflow: 3900 CFM Entering Air Temp: 57.9 F Leaving Air Temp: 92.9 F Gas Input Capacity: / MBH Gas Heating Capacity: MBH Temperature Rise: 35.0 F NOTE: Second Stage Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 981 Fan Power: 2.53 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Compressor #2 RLA: 10.6 Compressor #2 LRA: 75 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 3.1 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 4.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 30.5 Power Supply MOCP (Fuse or HACR): 40 Min. Unit Disconnect FLA: 32 Min. Unit Disconnect LRA: 190 Electrical Convenience Outlet: None Acoustics Packaged Rooftop Builder 1.20 Page 7 of 34

12 CURBS & WEIGHTS DIMENSIONS - CHASSIS 3 48TC Fig Dimensions 48TC -14 C

13 CURBS & WEIGHTS DIMENSIONS - CHASSIS 3 (cont.) 48TC GASKET (SUPPLIED WITH CURB) NAIL C08522 COUNTER FLASHING (FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) CANT STRIP (FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) Fig Curb Installation Detail (Typical) C07457 C D B A Fig Curb Dimensions C08309 Fig Service Clearance LOC DIMENSION CONDITION 48 (1219 mm) Unit disconnect is mounted on panel 36 (914 mm) If dimension--- B is 12 (305 mm) A 18 (457 mm) No disconnect, convenience outlet option 18 (457 mm) Recommended service clearance (use electric screwdriver) 12 (305 mm) Minimum clearance (use manual ratchet screwdriver) 36 (914 mm) Unit has economizer B 12 (305 mm) If dimension--- A is 36 (914 mm) Special Check for sources of flue products within 10---ft of unit fresh air intake hood C 36 (914 mm) Side condensate drain is used 18 (457 mm) Minimum clearance 48 (1219 mm) No flue discharge accessory installed, surface is combustible material D 42 (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) 36 (914 mm) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Special Check for adjacent units or building fresh air intakes within 10---ft of this unit s flue outlet C

14

15 Performance Summary For PAC-B2 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSA07A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 765 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 1920 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 81.9 F Evaporator Entering Air WB: 65.1 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 53.9 F Evaporator Leaving Air WB: 52.8 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 4.80 kw Coil Bypass Factor: Heating Performance Heating Airflow: 1920 CFM Entering Air Temp: 60.2 F Leaving Air Temp: 88.7 F Gas Input Capacity: 50.0 / 72.0 MBH Gas Heating Capacity: MBH Temperature Rise: 28.5 F NOTE: Second Stage Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 753 Fan Power: 1.33 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 3.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.1 Power Supply MOCP (Fuse or HACR): 25 Min. Unit Disconnect FLA: 17 Min. Unit Disconnect LRA: 94 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Packaged Rooftop Builder 1.20 Page 5 of 34

16 Performance Summary For PAC-C3,C4 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSD08A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 925 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 2500 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 77.7 F Evaporator Entering Air WB: 68.0 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 56.4 F Evaporator Leaving Air WB: 56.4 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 6.17 kw Coil Bypass Factor: Heating Performance Heating Airflow: 2500 CFM Entering Air Temp: 77.8 F Leaving Air Temp: F Gas Input Capacity: 90.0 / MBH Gas Heating Capacity: MBH Temperature Rise: 38.1 F NOTE: Second Stage Supply Fan External Static Pressure: 0.75 in wg Fan RPM: 754 Fan Power: 0.96 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 6.1 Compressor #1 LRA: 41 Compressor #2 RLA: 6.1 Compressor #2 LRA: 41 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 2.6 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.9 Power Supply MOCP (Fuse or HACR): 20 Min. Unit Disconnect FLA: 19 Min. Unit Disconnect LRA: 101 Electrical Convenience Outlet: None Acoustics Packaged Rooftop Builder 1.20 Page 9 of 34

17 Performance Summary For PAC-D2 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSD08A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 925 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 2600 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 85.2 F Evaporator Entering Air WB: 68.0 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 57.2 F Evaporator Leaving Air WB: 56.7 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 6.17 kw Coil Bypass Factor: Heating Performance Heating Airflow: 2600 CFM Entering Air Temp: 41.0 F Leaving Air Temp: 77.7 F Gas Input Capacity: 90.0 / MBH Gas Heating Capacity: MBH Temperature Rise: 36.7 F NOTE: Second Stage Supply Fan External Static Pressure: 1.50 in wg Fan RPM: 993 Fan Power: 1.77 BHP NOTE:Medium Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 6.1 Compressor #1 LRA: 41 Compressor #2 RLA: 6.1 Compressor #2 LRA: 41 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 2.6 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.9 Power Supply MOCP (Fuse or HACR): 20 Min. Unit Disconnect FLA: 19 Min. Unit Disconnect LRA: 101 Electrical Convenience Outlet: None Acoustics Packaged Rooftop Builder 1.20 Page 11 of 34

18 Performance Summary For PAC-D3 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSA07A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 765 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 83.0 F Evaporator Entering Air WB: 66.3 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 55.5 F Evaporator Leaving Air WB: 54.5 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 4.80 kw Coil Bypass Factor: Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 50.3 F Leaving Air Temp: 77.6 F Gas Input Capacity: 50.0 / 72.0 MBH Gas Heating Capacity: MBH Temperature Rise: 27.3 F NOTE: Second Stage Supply Fan External Static Pressure: 1.50 in wg Fan RPM: 890 Fan Power: 2.14 BHP NOTE: Medium Static Fan Option Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 3.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.1 Power Supply MOCP (Fuse or HACR): 25 Min. Unit Disconnect FLA: 17 Min. Unit Disconnect LRA: 94 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Packaged Rooftop Builder 1.20 Page 13 of 34

19 Performance Summary For PAC-D6 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSA07A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 765 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 81.8 F Evaporator Entering Air WB: 67.2 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 56.2 F Evaporator Leaving Air WB: 55.4 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 4.80 kw Coil Bypass Factor: Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 53.2 F Leaving Air Temp: 80.5 F Gas Input Capacity: 50.0 / 72.0 MBH Gas Heating Capacity: MBH Temperature Rise: 27.3 F NOTE: Second Stage Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 761 Fan Power: 1.38 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 3.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.1 Power Supply MOCP (Fuse or HACR): 25 Min. Unit Disconnect FLA: 17 Min. Unit Disconnect LRA: 94 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Packaged Rooftop Builder 1.20 Page 17 of 34

20 Performance Summary For PAC-E7,F7 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSA07A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 765 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 41.3 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 1800 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 90.0 F Evaporator Entering Air WB: 70.4 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 58.1 F Evaporator Leaving Air WB: 57.5 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 4.81 kw Coil Bypass Factor: Heating Performance Heating Airflow: 1800 CFM Entering Air Temp: 41.0 F Leaving Air Temp: 71.3 F Gas Input Capacity: 50.0 / 72.0 MBH Gas Heating Capacity: MBH Temperature Rise: 30.3 F NOTE: Second Stage Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 742 Fan Power: 1.26 BHP NOTE: Standard Static Fan Option Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 9.7 Compressor #1 LRA: 62 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 3.4 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.1 Power Supply MOCP (Fuse or HACR): 25 Min. Unit Disconnect FLA: 17 Min. Unit Disconnect LRA: 94 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Packaged Rooftop Builder 1.20 Page 23 of 34

21 Performance Summary For PAC-E8,F8 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCSD08A2F6-0A3A0 ARI EER: IEER: 13.0 Base Unit Weight: 925 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 2250 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 90.0 F Evaporator Entering Air WB: 70.2 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 57.5 F Evaporator Leaving Air WB: 57.4 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 6.18 kw Coil Bypass Factor: Heating Performance Heating Airflow: 2250 CFM Entering Air Temp: 41.0 F Leaving Air Temp: 83.4 F Gas Input Capacity: 90.0 / MBH Gas Heating Capacity: MBH Temperature Rise: 42.4 F NOTE: Second Stage Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 819 Fan Power: 1.03 BHP NOTE:Standard Static Fan Option. A field-supplied drive is required. Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 6.1 Compressor #1 LRA: 41 Compressor #2 RLA: 6.1 Compressor #2 LRA: 41 Outdoor Fan Motor Qty: 2 Outdoor Fan FLA (ea): 0.8 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 2.6 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 17.9 Power Supply MOCP (Fuse or HACR): 20 Min. Unit Disconnect FLA: 19 Min. Unit Disconnect LRA: 101 Electrical Convenience Outlet: None Acoustics Packaged Rooftop Builder 1.20 Page 25 of 34

22 CURBS & WEIGHTS DIMENSIONS - 48HC HC Fig. 5 - Dimensions 48HC C

23 CURBS & WEIGHTS DIMENSIONS - 48HC (cont.) 48HC Fig. 6 - Dimensions 48HC C10154 C D B A Fig. 7 - Service Clearance C08337 LOC DIMENSION CONDITION 48 (1219 mm) Unit disconnect is mounted on panel A 18 (457 mm) No disconnect, convenience outlet option 18 (457 mm) Recommended service clearance 12 (305 mm) Minimum clearance 42 (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall) B 36 (914 mm) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Special Check for sources of flue products within 10---ft of unit fresh air intake hood C 36 (914 mm) Side condensate drain is used 18 (457 mm) Minimum clearance 48 (1219 mm) No flue discharge accessory installed, surface is combustible material D 42 (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) 36 (914 mm) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Special Check for adjacent units or building fresh air intakes within 10---ft of this unit s flue outlet 20

24

25 SUBMITTAL SUBMITTAL MicroMetl Down Discharge Economizer with 100% FORM NO P SUBMITTED TO EQUIPMENT: JOB NAME: DRAWN BY: COMPANY: M. HARGIS NOTES: DATE: 09 / 07 FEATURES: Gear driven dampers eliminate slippage associated with standard linkage. Designed specifically for down discharge applications. Easy to install. Easy to service. Lower static pressure loss through economizer dampers. Greater barometric relief capabilities. Factory assembled rainhood with aluminum filters in both outside air and relief hoods. Uses filter access door shipped with HVAC unit. Rainhoods are sloped for water run-off. Hardware cloth over relief damper. Many control systems, with plug-in harness, are available. Economizer includes modulating control system with dry bulb sensor. Shipping weight: 135 lbs Relief Capability for Carrier 48/50TF, HJ, TM HJQ Economizer motor and harness Gear driven dampers Sloped Access door shipped with HVAC unit Part Number: 0688HJ712DBEC Barometric Barometric Relief Relief Static Pressure (in w.g.) Side View Filters Evaporation coil 29 3/8" Outside air Aluminum water entrainment filters Rainhood ships fully assembled Relief air THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION 3035 N. SHADELAND AVENUE, SUITE 300 INDIANAPOLIS, IN MICROMETL WEST 202 SOUTH 18TH ST. SPARKS, NV Relief Airflow (CFM) Static Static Pressure Pressure Loss Loss Through Economizer Airflow (cfm) Static Pressure Return Air Outside Air

26 Performance Summary For PAC-D4,D5,E5,F5 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCLA05A2F6-0A3A0 ARI SEER: Base Unit Weight: 590 lb Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.8 in Unit Height: 41.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 1200 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 82.0 F Evaporator Entering Air WB: 66.0 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 53.6 F Evaporator Leaving Air WB: 52.8 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 3.18 kw Coil Bypass Factor: Heating Performance Heating Airflow: 1200 CFM Entering Air Temp: 57.7 F Leaving Air Temp: 96.3 F Gas Input Capacity: 60.0 MBH Gas Heating Capacity: MBH Temperature Rise: 38.6 F Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 1153 Fan Power: 0.64 BHP NOTE: Medium Static Fan Option Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 6.2 Compressor #1 LRA: 41 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 2.1 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 10.8 Power Supply MOCP (Fuse or HACR): 15 Min. Unit Disconnect FLA: 11 Min. Unit Disconnect LRA: 49 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor Packaged Rooftop Builder 1.20 Page 15 of 34

27 Performance Summary For PAC-E1-4,F1-4 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCLA05A2F6-0A3A0 ARI SEER: Base Unit Weight: 590 lb Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.8 in Unit Height: 41.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 1360 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 81.2 F Evaporator Entering Air WB: 64.7 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 54.1 F Evaporator Leaving Air WB: 52.9 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 3.18 kw Coil Bypass Factor: Heating Performance Heating Airflow: 1360 CFM Entering Air Temp: 60.2 F Leaving Air Temp: 94.2 F Gas Input Capacity: 60.0 MBH Gas Heating Capacity: MBH Temperature Rise: 34.0 F Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 1197 Fan Power: 0.79 BHP NOTE: Medium Static Fan Option Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 6.2 Compressor #1 LRA: 41 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 2.1 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 10.8 Power Supply MOCP (Fuse or HACR): 15 Min. Unit Disconnect FLA: 11 Min. Unit Disconnect LRA: 49 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor Packaged Rooftop Builder 1.20 Page 19 of 34

28 Performance Summary For PAC-E6,F6 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM Part Number:48HCLA06A2F6-0A3A0 ARI SEER: Base Unit Weight: 600 lb Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.8 in Unit Height: 41.4 in Unit Voltage-Phase-Hertz: Air Discharge: Vertical Fan Drive Type: Belt Actual Airflow: 1550 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 94.0 F Evaporator Entering Air DB: 77.3 F Evaporator Entering Air WB: 63.9 F Entering Air Enthalpy: BTU/lb Evaporator Leaving Air DB: 51.9 F Evaporator Leaving Air WB: 51.6 F Evaporator Leaving Air Enthalpy: BTU/lb Gross Cooling Capacity: MBH Gross Sensible Capacity: MBH Compressor Power Input: 3.87 kw Coil Bypass Factor: Heating Performance Heating Airflow: 1550 CFM Entering Air Temp: 61.0 F Leaving Air Temp: 90.9 F Gas Input Capacity: 60.0 MBH Gas Heating Capacity: MBH Temperature Rise: 29.9 F Supply Fan External Static Pressure: 1.00 in wg Fan RPM: 1255 Fan Power: 0.99 BHP NOTE: Medium Static Fan Option Electrical Data Minimum Voltage: 414 Maximum Voltage: 506 Compressor #1 RLA: 7 Compressor #1 LRA: 52 Outdoor Fan Motor Qty: 1 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 2.6 Combustion Fan Motor FLA (ea): 0.25 Power Supply MCA: 12.3 Power Supply MOCP (Fuse or HACR): 15 Min. Unit Disconnect FLA: 12 Min. Unit Disconnect LRA: 69 Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor Packaged Rooftop Builder 1.20 Page 21 of 34

29 CURBS & WEIGHTS DIMENSIONS - 48HC NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS IN [ ] ARE IN MILLIMETERS. 33-3/8 [ 848] 2. CENTER OF GRAVITY 32-1/4 [ 818] ECONOMIZER HOOD (OPTIONAL) 16 [ 406] 3. DIRECTION OF AIR FLOW C ] 25-5/8 [ 652] RETURN AIR 10-7/8 [ 277] RETURN AIR 18-1/8 [ 459] 16-1/8 [ 411] 14-1/4 [ 363] 12-1/4 [ 312] SEE THRU THE BASE CHART W X Y Z E ALT. CONDENSATE DRAIN OPENING IN BASEPAN 6-1/4 [ 157] 17-3/4 [ 451] SUPPLY AIR 26-1/2 [ 673] 29-3/8 [ 747] SUPPLY AIR 48HC 10-1/2 [ 265] 1-1/4 [ 32] 25 [ 636] 4 [ 100] FLUE HOOD TOP 12-1/8 [ 307] 18-1/2 [ 470] 3-3/8 [ 85] 11-3/8 [ 289] 6-1/8 [ 155] E STD. CONDENSATE DRAIN 16-3/4 [ 427] SUPPLY AIR 25-1/8 [ 638] RETURN AIR FILTER OUTSIDE AIR 21-1/4 [ 539] J OPTIONAL FACTORY INSTALLED DISCONNECT CONTROL BOX ACCESS PANEL F INDOOR BLOWER ACCESS HANDLE 6-5/8 [ 168] 7 [ 177] 6 [ 152] 26-3/4 [ 681] SUPPLY AIR 31-1/4 [ 793] RIGHT RETURN AIR BAROMETRIC RELIEF FLOW HANDLE 30-1/8 [ 764] 8-3/8 [ 213] 74-3/8 [ 1888] FRONT K 4-5/8 [ 118] CONDENSER COIL OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET A, B, G D ELECTRICAL DISCONNECT LOCATION 19-1/2 [ 494] FILTER ACCESS PANEL (TOOL-LESS) INDOOR COIL ACCESS PANEL COMP. ACCESS PANEL CONDENSER COIL 6-5/8 [ 168] 3-3/4 [ 95] 46-3/4 [ 1187] LEFT THRU-THE-BASE CHART THESE HOLES REQUIRED FOR USE CRBTMPWR001A01, 003A01 BACK 2-5/8 [ 67] TYP CURB WIDTH A B C D E F G CONNECTION SIZES 1 3/8" [35] DIA FIELD POWER SUPPLY HOLE 2" [50] DIA POWER SUPPLY KNOCKOUT 1 3/4" [51] DIA GAUGE ACCESS PLUG 7/8" [22] DIA FIELD CONTROL WIRING HOLE 3/4"-14 NPT CONDENSATE DRAIN 1/2"-14 NPT GAS CONNECTION 2 1/2 " [64] DIA POWER SUPPLY KNOCK-OUT THREADED CONDUIT SIZE WIRE USE REQ'D HOLE SIZES (MAX.) W 1/2" ACC. 7/8" [22.2] X 1/2" 24V 7/8" [22.2] Y * 3/4" (001,003) POWER 1 1/8" [28.4] Z** (003) 1/2" FPT GAS 1 3/16" [30.0] FOR "THRU-THE-BASEPAN" FACTORY OPTION, FITTINGS FOR ONLY X,Y, & Z ARE PROVIDED * SELECT EITHER 3/4" OR 1/2" FOR POWER, DEPENDING ON WIRE SIZE UNIT J K 48HC-A04 48HC-A05 48HC-A /8 [847] 41 3/8 [1051] 41 3/8 [1051] 18 5/8 [472] 14 7/8 [377] 14 7/8 [377] ** (001) PROVIDES 3/4" FPT THRU CURB FLANGE & FITTING. Fig. 1 - Dimensions 48HC C

30 CURBS & WEIGHTS DIMENSIONS - 48HC (cont.) STD. UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (D) UNIT C.G. HEIGHT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 48HC-A /8 [918] 24 3/8 [619] 19 [483] 48HC-A /4 [921] 23 3/8 [594] 20 1/8 [511] 48HC-A /8 [911] 23 1/4 [591] 19 1/2 [495] *- STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTINS AND ACCESSORIES REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B Y Z 48HC CORNER D X CORNER C TOP Fig. 2 - Dimensions 48HC C10152 C D B A Fig. 3 - Service Clearance C08337 LOC DIMENSION CONDITION 48 (1219 mm) Unit disconnect is mounted on panel A 18 (457 mm) No disconnect, convenience outlet option 18 (457 mm) Recommended service clearance 12 (305 mm) Minimum clearance 42 (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall) B 36 (914 mm) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Special Check for sources of flue products within 10---ft of unit fresh air intake hood C 36 (914 mm) Side condensate drain is used 18 (457 mm) Minimum clearance 48 (1219 mm) No flue discharge accessory installed, surface is combustible material D 42 (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) 36 (914 mm) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Special Check for adjacent units or building fresh air intakes within 10---ft of this unit s flue outlet 17

31 Side View THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION 3035 N. SHADELAND AVENUE, SUITE 300 INDIANAPOLIS, IN MICROMETL WEST 202 SOUTH 18TH ST. SPARKS, NV Filters Evaporation coil S U B M I T T A L MicroMetl Down Discharge Economizer with 100% Relief FORM NO P SUBMITTED TO COMPANY: DRAWN BY: JOB NAME: EQUIPMENT: NOTES: DATE: 1 / 07 Capability for Carrier 48/50TC A/B04-A/B07; 50TCQ A04-A07; 48/50HC A04-A06; 48/50TF,TM,HJ,TFQ ; 48/50HE Units Static Pressure Loss Through Economizer Part Number: Barometric Relief FEATURES: Gear driven dampers eliminate slippage associated with standard linkage. Designed specifically for down discharge applications. Easy to install. Easy to service. Lower static pressure loss through economizer dampers. Greater barometric relief capabilities. Factory assembled rainhood with aluminum filters in both outside air and relief hoods. Uses filter access door shipped with HVAC unit. Rainhoods are sloped for water run-off. Hardware cloth over relief damper. ECONOMIZER PART NO.S Economizer w/ no controls J A920 Economizer w/ fixed dry bulb controls Economizer w/ modulating enthalpy controls Economizer w/ modulating adjustable dry bulb controls Access door shipped with HVAC unit Drive gear attached to the motor Economizer motor and harness Gear driven dampers Sloped 19 1/4" Economizer includes Honeywell W7212 controller capable of CO2, demand control and power exhaust control. Outside air Aluminum water entrainment filters Rainhood ships fully assembled Relief air

32 Performance Summary For CU-B1-3,4 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 08:35AM Pipe Length Liquid Line Size Suction Line Size /2 1 1/ /2 1 1/ /2 1 1/ /2 1 3/8 38AUQ012/40RUQ012 System: 1 System Quantity: ft 0.0 Altitude: 11.0 ARI Conditions: 3.3 Hi_TempCOP: NA IPLV: System meets ASHRAE 90.1 min EER requirement. Liquid and Suction Line Sizing V-Ph-Hz F F in wg in wg in wg in wg in wg in wg 1 38AUQ 10 Tons Outdoor Unit Parameters Unit Quantity: Unit Model: Unit Size: No. of DX Circuits: Voltage: Clg Ent Air DB: Htg Ent Air DB: Indoor Unit External Static: Economizer Loss: Grille Loss: Plenum Loss: Acc. Heating Loss: Total Ext Static: V-Ph-Hz CFM MBH MBH F F BTU/lb F F BTU/lb 1 40RUQ 10 Tons NA Indoor Unit Parameters Unit Quantity: Unit Model: Unit Size: Coil Rows: No. of Splits: Voltage: Actual Airflow: Total Clg Cap.(Gross): Sensible Clg Cap.(Gross): Ent Air DB: Ent Air WB: Ent Enthalpy: Lvg Air DB: Lvg Air WB: Lvg Enthalpy: Coil Bypass Factor: MBH MBH kw F F Heat Pump System Htg HP Capacity: Htg HP Integrated Capacity: Heating HP Compressor Power: Htg Ent Air DB Temp: Htg Lvg Air DB: High Temp COP: in wg in wg in wg in wg in wg in wg RPM BHP BHP Amps Indoor Supply Fan 0.60 Indoor Unit External Static: 0.00 Economizer Loss: 0.00 Grille Loss: 0.00 Plenum Loss: 0.00 Acc. Heating Loss: 0.60 Total Ext Static: 862 Fan Speed: 2.00 Fan Power: 2.40 Fan Motor Max: 2.6 Fan Motor FLA: Standard Motor and Standard Drive Required. V-Ph-Hz Outdoor Electrical Data Unit Voltage: Amps 22.5 Unit#1 MCA: Amps 30.0 Unit#1 MOCP: NA Total Compressor Power of Unit #1: V 414 Voltage Range Min: V 506 Voltage Range Max: 16.7 Compressor RLA: 114 Compressor LRA: 1 Compressor Quantity: 2 Fan Motors Qty: Notice: Outdoor unit elect. data is based on V-Ph-Hz Indoor Electrical Data Unit Voltage: Amps 3.3 Unit MCA: Amps 15.0 Unit MOCP: Notice: Indoor unit elect. data is based on Motor is rated for tri voltage 208/230/ V. Factory wired for application. Acoustics Sound Power Levels, db re 10E-12 Watts Commercial Split Systems Builder 1.19d Page 1 of 2

33 Performance Summary For HP-E1-5 and F1-5 Project: LAUSD South Region HS 15 08/05/2010 Prepared By: 07:39AM System: 38AUQ008/40RUQ008 System Quantity: 2 Altitude: 0.0 ft ARI Conditions: 11.0 Hi_TempCOP: 3.3 IPLV: NA System meets ASHRAE 90.1 min EER requirement. Liquid and Suction Line Sizing Pipe Length Liquid Line Size Suction Line Size /2 1 1/ /2 1 1/ /2 1 1/ /2 1 1/8 Outdoor Unit Parameters Unit Quantity: 1 Unit Model: 38AUQ Unit Size: 7.5 Tons No. of DX Circuits: 1 Voltage: V-Ph-Hz Clg Ent Air DB: 94.0 F Htg Ent Air DB: 47.0 F Indoor Unit External Static: 0.50 in wg Economizer Loss: 0.00 in wg Grille Loss: 0.00 in wg Plenum Loss: 0.00 in wg Acc. Heating Loss: 0.00 in wg Total Ext Static: 0.50 in wg Heat Pump System Htg HP Capacity: MBH Htg HP Integrated Capacity: MBH Heating HP Compressor Power: 6.79 kw Htg Ent Air DB Temp: 70.0 F Htg Lvg Air DB: F High Temp COP: 3.3 Outdoor Electrical Data Unit Voltage: V-Ph-Hz Unit#1 MCA: 17.1 Amps Unit#1 MOCP: 25.0 Amps Total Compressor Power of Unit #1: NA Voltage Range Min: 414 V Voltage Range Max: 506 V Compressor RLA: 12.2 Compressor LRA: 100 Compressor Quantity: 1 Fan Motors Qty: 2 Notice: Outdoor unit elect. data is based on Indoor Unit Parameters Unit Quantity: 1 Unit Model: 40RUQ Unit Size: 7.5 Tons Coil Rows: 4 No. of Splits: 1 Voltage: 208/ V-Ph-Hz Actual Airflow: CFM Total Clg Cap.(Gross): 84.2 MBH Sensible Clg Cap.(Gross): 66.2 MBH Ent Air DB: 79.6 F Ent Air WB: 64.1 F Ent Enthalpy: BTU/lb Lvg Air DB: 53.5 F Lvg Air WB: 51.7 F Lvg Enthalpy: BTU/lb Coil Bypass Factor: NA Indoor Supply Fan Indoor Unit External Static: 0.50 in wg Economizer Loss: 0.00 in wg Grille Loss: 0.00 in wg Plenum Loss: 0.00 in wg Acc. Heating Loss: 0.00 in wg Total Ext Static: 0.50 in wg Fan Speed: 643 RPM Fan Power: 0.63 BHP Fan Motor Max: 2.40 BHP Fan Motor FLA: 5.2 Amps Standard Motor and Standard Drive Required. Indoor Electrical Data Unit Voltage: 208/ V-Ph-Hz Unit MCA: 6.5 Amps Unit MOCP: 15.0 Amps Notice: Indoor unit elect. data is based on Acoustics Sound Power Levels, db re 10E-12 Watts Commercial Split Systems Builder 1.19d Page 33 of 34

34 6 C09236

35 DIMENSIONS 40RUQ C RUQ*07, 08, 12 6

36 24ABB3 Baset13 Air Conditioner with Puronr Refrigerant Submittal Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 24ABB has been designed utilizing Carrier s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth s ozone layer. As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory ( for the most up -to -date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S SEER/ EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 75 dba S Sound level as low as 74 dba with accessory sound blanket Comfort S System supports Edger Thermidistatt or standard thermostat controls Reliability S S S S S S Durability Puronr refrigerant - environmentally sound, won t deplete the ozone layer and low lifetime servce cost. Scroll compressor Internal pressure relief valve Internal thermal overload Filter drier Balanced refrigeration system for maximum reliability WeatherArmort protection package: S Solid, durable sheet metal construction S Dense wire coil guard available Baked -on, complete outer coverage, powder paint S Applications S Long -line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to -20_F/-28.9_C)) with accessory kit

37 PHYSICAL DATA UNIT SIZE---VOLTAGE, SERIES Operating Weight lb (kg) Shipping Weight lb (kg) Compressor Type REFRIGERANT Control Charge lb (kg) 107 (48.5) 130 (59.0) 3.50 (1.59) 110 (49.9) 134 (60.8) 3.80 (1.72) 111 (50.3) 136 (61.7) 141 (64.0) 170 (77.1) Scroll Puron (R---410A) TXV (Puron Hard Shutoff) 4.10 (1.86) 5.34 (2.42) 190 (86.2) 218 (98.9) 5.84 (2.65) 186 (84.4) 224 (101.6) 7.00 (3.18) 190 (86.2) 226 (102.5) COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/4 Motor RPM COND COIL Face Area (Sq ft) Fins per In Rows Circuits VALVECONNECT.(In.ID) Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 3/4 3/4 3/4 7/8 7/8 7/ /8 Max Liquid Line{ 3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. { See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables (3.71) 24ABB3 3

38 ELECTRICAL DATA UNIT SIZE --- VOLTAGE, SERIES V/PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZE{ MIN WIRE SIZE{ MAX LENGTH ft. (m)} MAX LENGTH ft. (m)} MAX MIN LRA RLA FLA 60 C 75 C 60 C 75 C MAX FUSE** or CKT BRK AMPS (20.1) 63 (21.0) (13.4) 42 (12.8) (14.0) 44 (13.4) /230/ (18.6) 58 (17.7) (16.2) 51 (15.5) (23.2) 72 (22.2) (18.9) 55 (16.8) 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30_C, consult table of the NEC (NFPA 70). The ampacity of non---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article If other than uncoated (no---plated), 60 or 75_C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70). } Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time --- Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA ---RatedLoadAmps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards ABB3 A-WEIGHTED SOUND POWER LEVEL UNIT SIZE --- VOLTAGE, SERIES STANDARD RATING (dba) TYPICAL OCTAVE BAND SPECTRUM (dba, without tone adjustment) NOTE: Tested in accordance with ARI Standard (not listed in AHRI). A-WEIGHTED SOUND POWER LEVEL WITH SOUND SHIELD UNIT SIZE --- VOLTAGE, SERIES STANDARD RATING (dba) TYPICAL OCTAVE BAND SPECTRUM (dba, without tone adjustment) NOTE: Tested in accordance with ARI Standard (not listed in AHRI). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE--- VOLTAGE & SERIES REQUIRED SUBCOOLING _F (_C) (5.6) (5.6) (5.6) (7.8) (5.6) (8.3) (7.2) 9

39 24ABB3 DIMENSIONS - ENGLISH UNIT SERIES CHARACTERISTICS ELECTRICAL A B C D E F G K L M N P WEIGHT OPERATING (lbs) SHIPPING WEIGHT (lbs) SHIPPING DIMENSIONS (L x W x H) 24ABB318 1 XOOO 23 1/2" 25 5/16" 3 3/4" 3/4" 4 7/16" 18 1/16" 7 13/16" 2 13/16" 1/2" 16 1/2" 15" 12" /4" X 27 3/8" X 33 1/2" 24ABB324 1 XOOO 23 1/2" 25 5/16" 3 3/4" 3/4" 4 7/16" 18 1/16" 7 13/16" 2 13/16" 1/2" 16 1/2" 15" 12" /4" X 27 3/8" X 33 1/2" 24ABB330 1 XOOO 23 1/2" 28 11/16" 3 3/4" 3/4" 4 7/16" 18 1/16" 7 13/16" 2 13/16" 1/2" 16 1/2" 15" 14" /4" X 27 3/8" X 33 1/2" 24ABB336 1 XOOO 25 3/4" 32 5/16" 3 7/8" 7/8" 4 7/16" 21 1/4" 9 1/8" 2 15/16" 5/8" 14 1/4" 10 1/2" 16" /8" X 30 1/16" X 35 15/16" 24ABB342 0 XOOO 31 3/16" 32 5/16" 3 7/8" 7/8" 6 9/16" 24 11/16" 9 1/8" 2 15/16" 5/8" 15 3/4" 16 1/4" 13 3/4" /8" X 35 1/2" X 35 15/16" 24ABB348 1 XOOO 31 3/16" 35 3/4" 3 7/8" 7/8" 6 9/16" 24 11/16" 9 1/8" 2 15/16" 5/8" 16 3/8" 15 3/8" 15 1/4" /8" X 35 1/2" X 39 3/8" 24ABB360 1, 2 XOOO 31 3/16" 25 1/2" 3 7/8" 7/8" 6 9/16" 24 11/16" 9 1/8" 2 15/16" 5/8" 14 1/8" 15 3/8" 11 3/8" /8" X 35 1/2" X 32 9/16" X = YES O=NO NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 ı$f, MAX. 125 ı$f / SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY. 5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. A SQ. G M AIR IN AIR DISCHARGE AIR DISCHARGE B FIELD CONTROL SUPPLY CONN. 7/8" HOLE FIELD POWER SUPPLY CONN. 7/8" HOLE WITH 1 1/8" KNOCKOUT AIR IN N F AIR IN P 3" E C 31/2" VAPOR D LINE CONN. 17/8" L 5/16" K AIR IN MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS 18,24, /2" X 23 1/2" 36 26" X 26" 42,48, /2" X 31 1/2" - 35" X 35" 3/8" TIEDOWN KNOCKOUTS (2) PLACES 10

40 MEETS 2006 DOE REQUIREMENTS (1) HBX0-120 Series Vertical / Horizontal Air Handler 120V-Cooling or Heat pump 2-5 tons Description : The HBX0-120 series air handler is designed to offer the industry an air handler that includes every available feature as well as up to 13 SEER, depending on the selected outdoor unit. The HBX0-120 is completely factory assembled with a cooling coil, 120V motor, 24V transformer, horizontal drain pan, and throw away filter. All components are installed within a fully insulated, galvanized steel cabinet. (1) First Co's customer is ultimately responsible for confirming which fan coil models are compatible with selected outdoor unit(s) and which expansion valves (if any) are required. To determine approved indoor/outdoor matches, go to: or contact the factory. New Feature: Field or factory installable TXV s for optimum cooling performance. NOW AVAILABLE WITH FIELD OR FACTORY INSTALLED R22 OR R410A EXPANSION VALVES FEATURES: 1. Factory installed horizontal drain pan (Left or Right side down) 2. Compatible with all major brands of split condensing units and heat pumps 3. Piston-type metering device on cooling coil or field or factory installed R22 or R410a TXV s 4. Factory installed filter 5. Copper tube cooling coils 6. Primary and secondary drain connections on cooling coil 7. Fully insulated and painted galvanized steel cabinet Table of Contents Page # Description... 1 Features... 1 Efficiency... 2 Components... 2 Cabinets... 2 Installation... 2 Accessories... 2,4 Physical Dimensions... 3 Blower Data... 3 Model Numbers... 4 FIRST CO. - P.O. Box Dallas, Texas Ph. (214) Fax (214)

41 HBX0-120 Series DX / Heat Pump Efficiency: The HBX0-120 series air handler is the latest state-of-the-art air handler for heat pump or straight cool (DX) operation. Depending on the condensing unit or heat pump used, cooling efficiency is up to 14 SEER (depending on the selected outdoor unit). Cooling coils have either piston type metering devices, or R22 or R410a TXV s and are circuited for cooling or heat pump operation. First Co's customer is ultimately responsible for confirming which fan coil models are compatible with selected outdoor unit(s) and which expansion valves (if any) are required. To determine approved indoor/outdoor matches, go to: or contact the factory Components: Each air handler includes a high efficiency cooling coil, 120V fan motor, 24V transformer, horizontal drain pan, and throw away filter. Cabinets: Cabinets are fully insulated. Installation: No modification is required for vertical or horizontal (right-to-left) airflow. A horizontal drain pan is factory installed for right-to-left airflow and can be re-positioned within the cabinet to offer left-toright airflow. Accessories: Accessories include cooling / heat pump TXV kits. (See page 4) 3-WAY AIRFLOW -2-

42 HBX0-120 Series D PHYSICAL DIMENSIONS UNIT MODEL A B C D E F G H J LIQ. (SWEAT) SUCT. (SWEAT) FILTER 24HBX / /8 5/8 18 X 20 X 1 36HBX / /8 3/4 20 X 22 X 1 48/60HBX /4 26-1/ /4 18-1/4 8-7/8 1/2 7/8 20 X 25 X 1 (See P.4 for Model Numbers) BLOWER DATA UNIT MODEL NOM. COOL TONS MOTOR HP-AMP (120V) MIN. CKT. AMPACITY MAX. CKT. PROTECTION 24HBX / HBX / HBX / HBX / MOTOR SPEED HIGH MED-HI MED-LOW LOW HIGH MED-HI MED-LOW LOW HIGH MED LOW HIGH MED LOW CFM vs. EXTERNAL STATIC PRESSURE

43 Model Numbers: MODEL SIZE (BTU) MODEL (PISTON) MODEL (R22 TXV) FACTORY INSTALLED TXV S MODEL (R410a TXV) 24,000 24HBX HBX0-120 w/r22 TXV 24HBX0-120 w/r410a TXV 36,000 36HBX HBX0-120) w/r22 TXV 36HBX0-120 w/r410a TXV 42,000/48,000 48HBX HBX0-120 w/r22 TXV 48HBX0-120 w/r410a TXV 60,000 60HBX HBX0-120 w/r22 TXV 60HBX0-120 w/r410a TXV All TXV's are approved for cooling only or heat pump operation. NOTE: Expansion valve requirement depends on the selected outdoor unit. Go to or contact the factory for assistance. ACCESSORIES - (all field installed) EXPANSION VALVE KITS (Field installed) (cooling only or heat pump) PART NUMBER R22 FITS 9EVR HBX EVR HBX EVR /60HBX0-120 R410a 9EVR HBX EVR HBX EVR /60HBX0-120 NOTES: 1. Above expansion valve kits are approved for both cooling only (non heat pump) and heat pump applications. 2. Valves are external equalizing, internal bleed. 3. Valves have screw-on connections. In keeping with its policy of continuous progress and product improvement, First Operations reserves the right to make changes without notice. Maintenance for all First Co. products is available under Product Maintenance at www. firstco.com. Catalog HBX

44 25HBB3 Base 13 Heat Pump with Puronr Refrigerant 1---1/2 to 5 Nominal Tons (Sizes 18 to 60) Submittal Data the environmentally sound refrigerant Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 25HBB has been designed utilizing Carrier s Puron refrigerant. The environmentally sound refrigerant allows consumers to make a responsible decision in the protection of the earth s ozone layer. As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory ( for the most up -to -date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 13 SEER/ EER/ HSPF (nominal) S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 72 dba S Sound levels as low as 70 dba with accessory sound blanket Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant - environmentally sound, won t deplete the ozone layer and low lifetime service cost. S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High pressure switch S Loss of charge switch S Filter drier S Balanced refrigeration system for maximum reliability Durability WeatherArmort protection package: S Solid, durable sheet metal construction S Dense wire coil guard S Baked -on powder paint Applications S Long -line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to -20_F/-28.9_C) with accessory kit Warranty S 5 year limited compressor warranty S 5 year limited parts warranty

45 PHYSICAL DATA UNIT SIZE SERIES Operating Weight lb (kg) (67.13) (73.48) (84.37) (78.02) (111.58) (108.86) (113.40) Shipping Weight lb (kg) (78.93) (85.73) (97.52) (93.89) (126.10) (124.28) (127.91) Compressor Type Scroll REFRIGERANT Puron (R---410A) Control TXV (Puron Hard Shutoff) Charge lb (kg) (2.31) (2.68) (3.72) (3.08) (3.81) (5.17) (5.13) Outdoor Heating Piston # COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) Motor HP 1/10 1/10 1/10 1/8 1/5 1/4 1/4 Motor RPM COND COIL Face Area (Sq ft) Fins per In Rows Circuits VALVE CONNECT. (In.) ID Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In.) OD Rated Vapor* 5/8 5/8 3/4 3/4 7/8 7/ /8 Liquid 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. 25HBB3 VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered Long line when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m) Unit Nominal Size (Btuh) 18, Stage Puron HP 24, Stage Puron HP 30, Stage Puron HP 36, Stage Puron HP 42, Stage Puron HP 48, Stage Puron HP 60, Stage Maximum Liquid Line Diameters (In. OD) 3/8 Vapor Line Diameters (In.) OD ( ) Standard Application ( ) ( ) when outdoor unit is above indoor unit, and 60 ft. (18.3 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for vapor tube diameters based on the total length to minimize the cooling capacity loss. Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) ( ) Long Line Application Requires Accessories ( ) ( ) ( ) ( ) ( ) 1/ / / / / / / / / / / / / / / / / Puron HP Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines 3

46 ELECTRICAL DATA UNIT SIZE V/PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZE MIN WIRE SIZE MAX LENGTH ft (m) MAX LENGTH ft (m) MAX MIN LRA RLA FLA 60 C 75 C 60 C 75 C (20.1) 62 (18.9) (14.3) 45 (13.7) 25 MAX FUSE* *or CKT BRK AMPS (17.7) 56 (17.1) /230/ (17.7) 55 (16.8) (23.5) 73 (22.3) (33.2) 104 (31.7) (27.7) 87 (26.5) 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30_C, consult table of the NEC (ANSI/NFPA 70). The ampacity of non---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60_C conditions, per the NEC (ANSI/NFPA 70) Article If other than uncoated (no---plated), 60 or 75_C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time --- Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- RatedLoadAmps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2001 requirements of ASHRAE Standards HBB3 A -WEIGHTED SOUND POWER STANDARD TYPICAL OCTAVE BAND SPECTRUM (dba, without tone adjustment) UNIT SIZE RATING (dba) NOTE: Tested in accordance with ARI Standard (not listed in ARI). A -WEIGHTED SOUND POWER WITH SOUND HOOD STANDARD UNIT SIZE RATING TYPICAL OCTAVE BAND SPECTRUM (dba, without tone adjustment) (dba) NOTE: Tested in accordance with ARI Standard (not listed in ARI). CHARGING SUBCOOLING (TXV -TYPE EXPANSION DEVICE) UNIT SIZE---SERIES REQUIRED SUBCOOLING F ( C) (5.6) (6.7) (6.1) (5.0) (6.1) (6.1) (6.7) 7

47 DIMENSIONS 25HBB3 8

48 "VARIABLE SPEED" V_HBX Series Variable Speed Tons Cooling and Heat Pump 0-25kW Electric Heat Upflow / Horizontal The V_HBX series includes a programmable, high efficiency motor that redefines comfort and energy savings. The V_HBX motor automatically adjusts its torque and speed to maintain a pre-programmed level of constant airflow over a wide range of external static pressures. This variable speed technology offers better indoor air quality, more precise humidity control, quieter operation, consistent indoor air temperature, and lower utility bills High Efficiency - At full load conditions the V_HBX motor is 20% more efficient than an induction motor and at constant fan speed it consumes only watts of power compared to 400 watts for a standard induction motor. In addition, the V_HBX includes a high efficiency "A" coil with factory installed TXV for precise refrigerant control in either cooling or heat pump mode. (1) First Co's customer is ultimately responsible for confirming which fan coil models are compatible with selected outdoor unit(s) and which expansion valves are required. To determine approved indoor/outdoor matches, go to or contact the factory. VOHBX Model - Reversing valve energizes in cooling mode VBHBX Model - Reversing valve energizes in heating mode Variable Speed Motor Quiet Operation - The versatile V_HBX motor quietly "ramps up" when the unit is turned on and "ramps down" when the thermostat is satisfied, eliminating the annoying sounds of changing airflow. Self-Regulating Constant Airflow - The V_HBX motor is factory programmed to maintain a predetermined level of airflow over a wide range of external static pressures, ensuring optimum system performance and whole-house comfort. The benefits of constant fan operation are: Consistent air distribution (and temperature) throughout the home Better indoor air quality (further improved with the addition of a high efficiency filter) - This allows the air to be filtered without excessive drafts and without sacrificing efficiency. Better humidity control - The V_HBX is designed to extract much more moisture from the air than a conventional system by slowing the airflow over the cooling coil. The result is an improved summer comfort level at higher indoor temperatures. Additional Standard Features Factory installed R22 or R410a TXV (cooling or heat pump operation) Factory installed electric heat (0-25kW) 208/240V motor Upflow / horizontal drain pans Higher efficiency pleated filter Factory installed disconnect switch (over 10kW) Compatible with major brands of split condensing units or heat pumps Primary and secondary drain connections on cooling coil Insulated cabinet with baked-on powder coat finish Compatible with most properly sized and installed zone control systems. Contact the zone control manufacturer. FIRST CO. - P.O. Box Dallas, Texas Ph. (214) Fax (214)

49 V_HBX Series Cooling with Electric Heat (See P.4 for Model Numbers) PHYSICAL DIMENSIONS UNIT MODEL A B C D E F G H J FILTER SIZE 24V_HBX / X 20 X 1 36V_HBX / X 22 X 1 48/60V_HBX /4 26-1/ /4 18-1/4 8-7/8 20 X 25 X 1 AIR FLOW DATA (see "heating select taps" below each table for proper field set-up) THERMOSTAT TERMINALS CONTROL BOARD SELECT TAPS HEAT TAP MODEL OPERATING MODE "X" ENERGIZED TERMINALS COOL TAP (See notes below) Y1 G O W1 A B C D A B C D COOLING X X X CONTINUOUS BLOWER X V_HBX HEAT PUMP HEATING X X ELECTRIC HEAT X Heating Select Taps A 2 ton outdoor unit with 0-10 kw electric heat B 2 ton outdoor unit with 0-5 kw max. electric heat C 1-1/2 ton outdoor unit with 0-10 kw electric heat D 1-1/2 ton outdoor unit with 0-5 kw max. electric heat COOLING X X X CONTINUOUS BLOWER X V_HBX HEAT PUMP HEATING X X ELECTRIC HEAT X Heating Select Taps A 3 or 2-1/2 ton outdoor unit with 0-15 kw electric heat B 3 or 2-1/2 ton outdoor unit with 0-10 kw max. electric heat C 2-1/2 ton outdoor unit with 0-10 kw electric heat D 2-1/2 ton outdoor unit with 0-5 kw max. electric heat UNIT SIZE COIL CONNECTIONS LIQUID SUCTION 24 3/8 5/8 36 3/8 3/4 46/60 1/2 7/8 ACCESSORIES: Programmable Thermostat Part Description Number Touchscreen, T832 7-day programmable, with humidity control For All Models NOTE: Contact factory for brochure COOLING X X X CONTINUOUS BLOWER X V_HBX HEAT PUMP HEATING X X ELECTRIC HEAT X Heating Select Taps A+10% 4 or 3-1/2 ton outdoor unit with kw electric heat A 4 or 3-1/2 ton outdoor unit with kw max. electric heat B 4 or 3-1/2 ton outdoor unit with 0-10 kw max. electric heat C 3-1/2 ton outdoor unit with kw electric heat D 3-1/2 ton outdoor unit with 0-10 kw max. electric heat T832 COOLING X X X CONTINUOUS BLOWER X V_HBX HEAT PUMP HEATING X X ELECTRIC HEAT X Heating Select Taps A 5 or 4 ton outdoor unit with kw electrric heat B 5 or 4 ton outdoor unit with 0-15 kw max. electric heat C 4 ton outdoor unit with kw electric heat D 4 ton outdoor unit with 0-10 kw max. electric heat Airflow shown are at standard air conditions, dry coil at 240 volts. Max. ext. static pressure is 0.50" wtr Notes: The cooling and heating speed taps are factory set on "A". The delay profile is factory set on "A" (Arid setting). The adjust profile is factory set on Normal. If humidistat function is activated the cooling CFM will be reduced by 20%. Adjust profile (+) will increase airflow by 10%, while tap (-) will decrease airflow by 10%. For additional sales and technical information on variable speed motors, visit Digital thermostats for these units must have a "C" terminal. -2-

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS SUBMITTAL ***FOR APPROVAL*** TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS Project 66 Orland Square Dr. Landlord Renovations Location Orland Park,

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

Advance Product Data

Advance Product Data EVOLUTION R V VARIABLE SPEED AIR CONDITIONER WITH PURONr REFRIGERANT 2, 3, AND 4-TON (5-TON COMING Q4 2014) Advance Product Data The Evolution V air conditioner offers high -efficiency variable speed performance

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 24VNA0 Infinityr Variable Speed Air Conditioner with Greenspeedr Intelligence 2to5NominalTons Product Data Carrier s 24VNA0 with Greenspeed R Intelligence is a variable speed cooling product providing

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS Infinityr 19 2 --- Stage Heat Pump with Puronr Refrigerant 2to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

Advance Product Data

Advance Product Data EVOLUTION R EXTREME VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT (2-5 Ton) Advance Product Data Bryant s Evolutionr Extreme is a breakthrough product providing up to 13 HSPF heating efficiency and

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched by

More information

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE RGS Product Specifications ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 7.5 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Product Data. Efficiency. S S Reliability

Product Data. Efficiency. S S Reliability 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH14 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Baset13 Air Conditioner with Puronr Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Advanced Product Data

Advanced Product Data 48PD and 50PD-05, 06 Displacement Ventilation or Single-Zone Variable Airflow Rooftop Units Single Package, Electric Cooling, Gas or Optional Electric Heating with PURON (R-410A) Refrigerant and COMFORTLink

More information

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24ABC6 Comfortt16 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Advance Product Data

Advance Product Data Comfort 14 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Advance Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS Product Data Bryant Air Conditioners with refrigerant provide a collection of features unmatched by any other

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons 116B Legacyt Line 16 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE RHS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, 15 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE IEER s up to 11.5 with single speed indoor fan motor and

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS WeatherExpert R Series Ultra High---Efficiency Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 07 --- 12 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Product Data KUWAIT SERIES

Product Data KUWAIT SERIES 50 Hz Packaged Rooftop Electric Cooling Units 18.17 to 30.01 kw 5to8.5Tons Product Data KUWAIT SERIES C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS

More information

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24AHA4 Performance Series Air Conditioner with Refrigerant 1-1/2 to 5 Nominal Tons Product Data Carrier air conditioners with refrigerant provide a collection of features unmatched by any other family

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S BH13NA 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH13 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

SUBMITTAL. Project. Cross Creek Elementary School. Date. Thursday, July 23, 2015

SUBMITTAL. Project. Cross Creek Elementary School. Date. Thursday, July 23, 2015 SUBMITTAL Project Cross Creek Elementary School Date Thursday, July 23, 2015 Table Of Contents FCU-72 3 Unit Report 4 Performance Summary 6 Acoustic Summary 10 Certified Drawing 12 Guide Specifications

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Input Cap. (Btuh) Stage 2

Input Cap. (Btuh) Stage 2 Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. RGS Product Specifications

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613 Packaged Heat Pump 14 SEER 3to5NominalTons Product Data C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS & ACCESSORIES... 5 AHRI CAPACITY RATING...

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Roof Top Packaged Unit (RTU-1) Specification

Roof Top Packaged Unit (RTU-1) Specification Roof Top Packaged Unit (RTU-1) Specification Item Tag(s) Qty Description Model Number A2 10 Ton 1 10 Ton R410A PKGD Unitary Gas/Electric TRANE: YHC120F3RLA--07C1 Product Data - 10 Ton R410A PKGD Unitary

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4**C Comfort 14 Heat Pump for Coastal Applications with r Refrigerant 1---1/5 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Product Data Bryant Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information