Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Size: px
Start display at page:

Download "Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry"

Transcription

1 The «Modular Rack Gas Generators» Solution Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry With Unique Remote Control Monitoring via internet! Remote PC monitoring via RS232/RS485/USB/LAN ALLIANCE, the partnership that keeps the gas flowing.

2 F-DGSI EXPERTISE IS ALWAYS ONE STEP AHEAD! WE HAVE DESIGNED NEW MODULAR RACK SOLUTION THAT CAN FULFILL THE NEEDS OF ANY GC PROCESSES. CONVENIENT COMPACT DESIGN. INCORPORATES THE LATEST TECHNOLOGY AVAILABLE - WITH REMOTE PC MONITORING. OUR NEW RACK GAS SOLUTION IS EXPANDABLE - MORE MODULES CAN BE ADDED AS YOUR DEMANDS INCREASE THE COMPLETE SOLUTION FOR PROCESS GC LABS WHY MODULAR RACK GENERATORS IS THE COMPLETE SOLUTION FOR YOUR LABS? Modular system offering a gas supply solution tailored to your application Stackable design allowing you to save space in the lab Combinations available for single and multiple process GC applications Very low maintenance throughout the range Touch screen display showing the status of the system with auto- diagnostics in case of alarms Rack H2 generator + Zero Air generator available: all in one box Unique Remote PC monitoring via USB/LAN.RS232 allowing remote control system for multiples modules, and to connect with the manufacturer for remote diagnostics

3 POSSIBLE COMBINATIONS ZERO AIR+N2 + ZERO AIR+H2 + ZERO AIR+H2 IN ONE BOX FID STATION AIR+N2+H2 + + I-FLOW-H2 STATION HYDROGEN GAS STATION HIGH FLOW

4 COMPACT, CONVENIENT, SAFE, MORE ECONOMIC THAN GAS CYLINDERS, DEWARS OR BULK STORAGE Compact : can be located either on the bench or on the floor next to your process instrument Convenient : No cylinder changes Safer : removes the need for long gas lines from cylinders and the risk of high pressure cylinders. No leaking gas lines Economic : No gas contract required thus giving a low and stable ongoing gas costs GET ALL THE BENEFITS OF THE H2 GENERATOR AS CARRIER GAS INSTEAD OF He Eliminate the risks in using Hydrogen as a Carrier Gas in GC Analysis Hydrogen has long been considered as the best carrier gas for gas chromatography. In many cases hydrogen has become the carrier gas of choice since it results in fast analysis, high efficiency, reduced costs, and prolonged column life. Fast analysis The diffusion rate of hydrogen and helium are roughly the same (both 3-4 times faster than N2), but hydrogen is half as viscous as helium and therefore the linear gas velocity is higher and retention times are shorter in isothermal analysis. High efficiency Hydrogen has the flattest Van Demeter curve. Compared to helium and nitrogen, hydrogen needs the lowest plate number to achieve the same resolution over a large range of linear velocity Prolonged column life For some applications, a temperature program can be used to speed up the analysis when using helium as a carrier gas, but this may result in a shorter lifetime of the column due to higher temperatures. Reduced costs Helium, a rival to Hydrogen has its advantages as a carrier gas for GC; but it also has key disadvantages which are cost and availability. A tank of GC quality hydrogen is approximately 3 times less expensive than its helium equivalent. The price disparity between the two will not improve as the existing helium reserves are drying up and the demand is increasing across different industries. The use of a hydrogen generator also provides long term cost savings. A hydrogen generator allows for the production of the gas on an as needed basis; which avoids the costs associated with storing gas.

5 WITHOUT ANY RISK! Designed to have a high level of operator safety Unique 9 stages, fail safe, explosion protection system. Automatic internal/external H2 leak detection. Patented gas/water separator electronically controlled Very small stored volume of H2 H2 gas is only generated on demand. STILL WORRIED! H2 sensor in option for carrier gas use The sensor will continuously monitors the atmosphere in the GC oven and transmits the data to the hydrogen generator. When the hydrogen concentration detected exceeds the threshold of safety, the hydrogen generator will be automatically blocked and reported audible and visual alarms. The oven is immediately shut off and the cooling flap opens.

6 Rack Hydrogen Gas Generator SENSITIVE HYDROGEN SERIES RACK-WM-H2 HIGH PURITY GRADE ANALYSIS SOLUTION FOR GC CARRIER GAS KEY FEATURES Suitable for Carrier Gas at low detection limits: Purity > % High pressure: 12 bar (174 psi); on request 16 bar (232 psi) Proven PEM Technology to generate Hydrogen safely and reliably Auto drying desiccant columns to ensure high level of purity Internal water tank level of 1.2 L electronically controlled with automatic water refill as standard Maintenance limited to replacing water filter Small and stackable Creates Hydrogen on demand, minimal storage of Hydrogen in the system Internal/external leak detection with automatic shutdown features Cascading option to combine multiple units for higher flow requirements Remote PC monitoring in standard via RS232/RS485/USB/LAN to interface the unit with customer s PC software (allow the end user to be connected with the manufacturer for remote diagnostics) LCD touch screen with indication in real time: H2 outlet pressure, H2 flow rate, water quality, water level, system status with auto-diagnostics of breakdown with alarms Hydrogen sensor available as option to work in safety mode when using H2 as carrier gas. HYDROGEN SERIES RACK-ND-H2 STANDARD PURITY GRADE ANALYSIS SOLUTION FOR GC FUEL GAS APPLICATIONS KEY FEATURES Suitable for Flame Gas at standard detection limits: Purity > % Proven PEM Technology to generate Hydrogen safely and reliably Desiccant Dryers to ensure high level of purity Internal water tank level of 1.2 L electronically controlled with automatic water refill as standard Maintenance limited to replacing water filter and desiccant sieve Small and stackable Creates Hydrogen on demand, minimal storage of Hydrogen in the system Internal/external leak detection with automatic shutdown features Cascading option to combine multiple units for higher flow requirements Remote PC monitoring in standard via RS232/RS485/USB/LAN to interface the unit with customer s PC software (allow the end user to be connected with the manufacturer for remote diagnostics) LCD touch screen with indication in real time: H2 outlet pressure, H2 flow rate, water quality, water level, cartridge saturation, system status with auto-diagnostics of breakdown with alarms Hydrogen sensor available as option to work in safety mode when using H2 as carrier gas.

7 MODELS RACK-ND-H2 Series RACK-WM-H2 Series H2 flow rate - cc/min H2 purity H2 dryer Delivery pressure Internal water tank with automatic refill 180, 260, 400 > % (O2 < 1ppm, H2O < -55 C (-67 F)) Simple dessicant cartridge 10 bar ( 145 psi) 1.2 liters 180, 260, 400, 500, 650, 800, 900, 1000, 1200 > % (O2 < 0.1ppm, H2O < -70 C (-94 F)) Innovative double column dryer system without maintenance 12 bar (174 psi), 16 bar (232 psi) on request External water tank Temperature range LCD touch screen In series Option Water quality Dimensions Outlet port Weight (kg/lbs) Power consumption 5L (10L optionnal) From 5-35 C (41-95 F) and humidity 80% to 25 C (77 F) Resolution 128 x 64 - touch screen with operating parameters, system status, alarms Communication port : RS-232, RS-485, USB, LAN Possible to work in parallel mode Deionised, ASTM II, < 0.1 μs Standard 19 Rack 4U-deep 40 cm 1/8 Swagelock From / depends of model From 200 W to 800 W depend of model Remote PC monitoring via RS232/RS485/USB/LAN

8 Combined Rack Hydrogen / Zero Air Generator in one box SERIE RACK-FID-H2 STANDARD PURITY GRADE ANALYSIS SOLUTION For GC Fuel Gas Applications For Continuous Emission and Air monitoring applications Combines the hydrogen series RACK-ND-H2 and Zero Air series ZA generators. Hydrogen gas is produced from deionized water using a Proton Exchange Membrane Technology. Zero Air is produced by purifying compressed air sourced from the air network KEY FEATURES For H2 part Suitable for Flame Gas at standard detection limits Purity > % Desiccant Dryers to ensure high level of purity Internal water tank level of 1.2 L electronically controlled with automatic water refill as standard Maintenance limited to replacing water filter and desiccant sieve Small and stackable Creates Hydrogen on demand, minimal storage of Hydrogen in the system Internal/external leak detection with automatic shutdown features Remote PC monitoring in standard via RS232 to interface the unit with customer s PC software (allow the end user to be connected with the manufacturer for remote diagnostics) LCD touch screen with indication in real time: H2 outlet pressure, H2 flow rate, water quality, water level, cartridge saturation, system status with auto-diagnostics of breakdown with alarms For Zero Air part CH4 < 0.05 ppm CO < 0.05 ppm External clean and dry air compressor bar (101 psi)

9 H2 / ZERO AIR ZA part need to be connected to an external clean and dry compressed air source H2 / Zero Air flow rate - cc/min H2 / Zero Air purity H2 delivery pressure Air inlet pressure (min/max) Air inlet quality required Air delivery pressure Internal water tank for H2 Water quality / supply pressure (min/max) Temperature / Humidity LCD touch screen RACK-FID-H RAC-FID-H RACK-FID-H / / / 1500 > % (O2 < 1 ppm, dewpoint H2O < -55 C (-67 F)), CH4 < 0.05 ppm 8 bar max (115 psi) Min. 3 bar (43 psi) - Max. 10 bar (145 psi) Max. inlet hydrocarbon content < 100 ppm ; water dewpoint < - 20 C (-4 F) 0.5 bar (7 psi) less than inlet air pressure 1.2 liters with electronic level control Deionized, ASTM II, < 0.1 μs / bar (3 psi) / 1 bar (14 psi) From 5 C to 35 C (41-95 F) / 80% at 25 C (77 F) Touch screen - Resolution 128 x 64 (operating parameters, system status, alarms) Dimensions Outlet ports H2/Zero Air Standard 19'' RACK 4U - 40 cm deep 1/8 Swagelock Weight (kg/lbs) 20 / / 48.5 Power consumption Power supply voltage / Fuse rating 400 W V ac / Hz - 1 A / 4 A V ac Electrical cable connection IEC 320-C13 Communication Software function Noise / IP rating RS232 Parallel mode, Canister Filling < 25 db(a) / IP20 Remote PC monitoring via RS232/RS485/USB/LAN

10 Rack N2 Gas Generator SENSITIVE ZERO NITROGEN SERIES RACK-ZN2. HP HIGH PURITY GRADE ANALYSIS SOLUTION FOR GC CARRIER GAS AND GCMS APPLICATION KEY FEATURES Suitable for Carrier Gas and Make Up Gas at low detection limits: Purity > % Generates Zero Nitrogen on demand from external compressed air Regenerative CMS columns remove Oxygen and moisture Catalyst chamber to remove Hydrocarbons (as methane) to <0.05 ppm Smart control of the inlet air flow, it is function of the real nitrogen flow used Ultra fast start-up time, quick to reach operating purity Minimum maintenance with an annual filter change USB port in series to remote the system anywhere in the world Small and stackable Dedicated Alliance Air Compressor available STANDARD NITROGEN SERIES RACK- N2.HP STANDARD PURITY GRADE ANALYSIS SOLUTION FOR GC CARRIER GAS, MAKE UP GAS KEY FEATURES Suitable for Carrier Gas and Make Up Gas at standard detection limits: Purity > % Generates Nitrogen on demand from external compressed air Regenerative CMS columns remove Oxygen and moisture Smart control of the inlet air flow, it is function of the real nitrogen flow used Ultra fast start-up time, quick to reach operating purity Minimum maintenance with an annual filter change USB port in series to remote the system anywhere in the world Small and stackable Dedicated Alliance Air Compressor available

11 MODELS N2.600.HP.D ZN2.600.HP.D N HP.D N2 outlet Flow rate (max) 600 cc/min 1000 cc/min Outlet pressure (min) Outlet pressure (max) Nitrogen purity O2 content Hydrocarbon content (CH4 free) Air inlet 1.0 bar ( 14 psi) Inlet pressure 2.0 bar ( - 29 psi) > % - (<5ppm 7 Bar (101 psi) inlet pressure) < 5 ppm - < 0.05 ppm - Particulate: <1 micron Air inlet requirement Dewpoint: -40 C (-40 F) Oil <0.01 mg/m³ Flow rate (max) 12 L/min 15L/min Min supply pressure Max supply pressure Min temperature Max temperature Communication 7 bar (101psi) 10 bar (145 psi) 1 C (34 F) 35 C (95 F) LCD with touch screen Yes Yes Yes RS232 RS485 USB General data Supply rating Connection type Installation power (max) Fuse rating Net Weight Dimensions Connections Outlet port Inlet port Operating conditions Temperature Humidity (max, non condensing) Noise IP rating Pollution degree rating Altitude X X X Vac / Hz - 2 A IEC320-C13 240W (280 VA) 4 A Vac (5 x 20 mm) < 25 kg / < 55 lbs Standard 19 Rack 5U deep 48 cm 1/4" female 1/4" female 5-35 C (41-95 F) 80% at 25 C (77 F) <25dB(A) IP20 2 (with no aromatic compounds) < 2000m

12 Rack Zero Air Gas Generator SERIES RACK-ZA FOR GC FUEL GAS APPLICATION FOR GAS SENSING KEY FEATURES Generates Zero Air on demand from clean and dry external compressed air Catalyst chamber to remove Hydrocarbons (as methane) to < 0.05 ppm Minimum maintenance with an annual filter change Small and stackable Status indicative lighting features Remote PC monitoring in standard via RS232 to interface the unit with customer s PC software (allow the end user to be connected with the manufacturer for remote diagnostics) Compatible with Alliance Air compressor Oil free Air compressor with dryer SERIES ALLIANCE AIR COMPRESSOR KEY FEATURES Suitable oil free air compressor for a variety of Modular Alliance zero air and N2 Generator combinations Minimal noise emission due to insulated compressor compartment Minimal vibration through especially developed compressor anti-vibration mounts Automatic drain fitted as standard Automatic stand-by-mode, when no compressed air is required, ensures the long compressor life Compressor service indication

13 MODELS RACK-ZA-1500 RACK-ZA-3000 RACK-ZA-6000 RACK-ZA RACK-ZA Flow rate (max) 1.5 L/min 3 L/min 6 L/min 15 L/min 30 L/min Outlet pressure (max) Total outlet hydrocarbon content Startup time Max inlet hydrocarbon content Water dewpoint Inlet air Supply pressure Dimensions 6.5 Bar (94 psi) bar (8 psi) at maximum flow < 0.05 ppm 40 min 100 ppm < -20 C (- 4 F) 3 bar (43 psi) - 10 bar (145 psi) Standard 19 Rack 4U deep 40 cm Weight (kg/lbs) 8 / 17 9 / / / 44 Supply voltage Installation Power (max) Inlet / outlet Connections V ac / Hz From 100 W to 200 W depending on models 1/8" Female MODEL Flow rate (max) Outlet pressure (max) Air outlet dewpoint Particles Electrical requirement Operating temperature Power consumption Dimensions ( W x H x D) ALLIANCE AIR COMPRESSOR 26 L/min 8 bar -20 C (- 4 F) < 0.1 microns V50/60 Hz 10A / V 50/60 Hz 2.45A 5-25 C (41-77 F) Watts 36 x 40 x 54 cm (14" x 16" x 21")

14 I-Flow-H2 Station HYDROGEN GAS STATION HIGH FLOW 3.3 L/min to 10L/min + Expandable Intelligent High pressure: 12 bar (174 psi); on request 16 bar (232 psi) High purity > % Proven Multilayer cell PEM Technology to generate Hydrogen safely and reliably Auto drying desiccant columns to ensure high level of purity Internal water tank level of 1.2 L electronically controlled with automatic water refill Maintenance limited to replacing water filter Creates Hydrogen on demand, minimal storage of Hydrogen in the system Internal/external leak detection with automatic shutdown features Cascading option to combine multiple units for higher flow requirements Remote PC monitoring in standard via RS232/RS485/USB/LAN to interface the unit with customer s PC software (allow the end user to be connected with the manufacturer for remote diagnostics) LCD touch screen with indication in real time: H2 outlet pressure, H2 flow rate, water quality, water level, system status with auto-diagnostics of breakdown with alarms Safety: smart humidity safety guard Plug and Play Hydrogen sensor available as option to work in safety mode when using H2 as carrier gas. Remote PC monitoring via RS232/RS485/USB/LAN

15 MODEL Electrolytic cell H2 purity Outlet pressure H2 dryer H2 flow rate cc/min (max) Communication Software functions Water Quality Water Supply pressure (min) Water Supply pressure (max) Water Supply flow-rate (min - max) Internal water tank capacity External water tank capacity Power supply connection type Power supply voltage Power supply current (max) i-flow-h2 STATION 10L New multilayer cell (PEM technology) > % (02 < 0.1 ppm, dewpoint H2O < -70 C (-94 F)) 1-12 bar ( psi), 16 bar (232 psi) on request Innovative double column dryer system without maintenance 3 x 3300 USB, RS485, RS232, optional LAN Parallel mode capability, Automatic tank refill, Fill canister function Deionized, ASTM II, < 0.1uS -0.2 bar (-3 psi) 1 bar (14 psi) 0.2 L/min L/min 1.2 L 10 L 3 x wires 4mm3 (2 wire + ground) Vac Single phase 51 A V ac / 24 A V ac Dimensions 59 x 164 x 81 cm (23" x 64" x 32") Net weight (kg/lbs) (water tank empty) Hydrogen outlet Connections Water inlet Connections < 180 / < x 1/8" 3 x Quick release push-in fitting

16 LAB GAS GENERATORS 8, 10 rue du Bois Sauvage, bat Q Evry France Tél. : +33(0) Fax. : +33(0) info@f-dgs.com CONCEPTION - IMPRESSION : DÉFICOM :

HFID Heated Total Hydrocarbon Analyzer Module

HFID Heated Total Hydrocarbon Analyzer Module Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation

More information

Series 9000 Total Hydrocarbon Analyzer

Series 9000 Total Hydrocarbon Analyzer Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides

More information

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd Selecting the right generator for your GC system Gas generators offer a guaranteed

More information

CALIDUS tm the Modular micro Gas Chromatograph

CALIDUS tm the Modular micro Gas Chromatograph CALIDUS tm the Modular micro Gas Chromatograph Sample Processing Unit Plug & Play Programmed Temperature Column Modules Plug & Play Detector Modules Flame Ionization Thermal Conductivity A CALIDUS micro

More information

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels. Gas Chromatograph Continuous Analysis of Ultra High Purity Argon to ppb levels Features Following on from the success of the AGC Series 100 Argon GC, AGC Instruments introduces the new NovaCHROM 2000 GC.

More information

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation Filtration Balston Membrane Nitrogen Generators Compressed Air Dryers 157 Parker Hannifin Corporation Membrane Air Dryers Provide Clean, Dry Compressed Air Offer a reliable, efficient, and economical alternative

More information

Nitrogen Generation Systems Compressed Air Dryers

Nitrogen Generation Systems Compressed Air Dryers Nitrogen Generation Systems Balston Balston offers both membrane and PSA technology. Balston Membrane combine superior coalescing technology with a proven, innovative membrane system to supply clean, dry

More information

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium

More information

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples Process and Air Monitoring Online GC systems for continuous monitoring of organic compounds in air and gaseous samples For 35 years AMA Instruments has developed and manufactured analytical devices and

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL LABORATORY ULTRA ZERO AIR GENERATOR ZAC-ULT Series USER MANUAL 166 Keystone Drive Montgomeryville, PA 18936 Telephone: 215-641-2700 Fax: 215-641-2714 Email: mtgmmville@matheson-trigas.com INT-0261-XX rev

More information

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax:

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax: Hydrogen Generator Model HPNM 1 Instruction manual 166 Keystone Drive Montgomeryville, PA 18936 Phone: 215-641-2700 Fax: 215-641-2714 Introduction Index INDEX... 2 INTRODUCTION... 3 SCOPE OF THE MANUAL...

More information

MDA-Range of Modular Desiccant Compressed Air System

MDA-Range of Modular Desiccant Compressed Air System MDA-Range of Modular Desiccant Compressed Air System Intelligent Air Technology MDA-Range of Modular Desiccant Compressed Air Dryers The Problem Compressed air is an essential power source that is widely

More information

User Manual. New Hy-PEM XP Rack Hydrogen made simple

User Manual. New Hy-PEM XP Rack Hydrogen made simple User Manual New Hy-PEM XP Rack Hydrogen made simple Index Pag. 1 Important warnings... 1 1.1 General warnings... 1 1.2 Safety information... 1 1.3 Terminology... 2 1.4 Legend of symbols... 2 1.5 Intended

More information

Recent Improvements in Process GC Instrumentation

Recent Improvements in Process GC Instrumentation ISA Houston, TX Oct., 15 2003 Recent Improvements in Process GC Instrumentation Dr. Jack Driscoll PID Analyzers, LLC copyright 2000-2006 PID Presentation Objectives A new Process GC has been developed

More information

DHR Accessories Requirements. Site Preparation Guide

DHR Accessories Requirements. Site Preparation Guide DHR Accessories Requirements Site Preparation Guide Revision C Issued May 2018 Table of Contents Table of Contents... 2 Smart Swap Requirements... 3 Air Chiller System (ACS)... 7-9 ETC Chiller Panel...

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

Gas Detection - GD -

Gas Detection - GD - s Gas Detection TECHNICAL SPECIFICATIONS Gas Detection DATA SHEE - GD - Continuing development sometimes necessitates specification changes without notice Technical Specifications 2008 GD-00 Gas Measuring

More information

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

White paper on the Dielectric Barrier Discharge Detectors. Introduction: White paper on the Dielectric Barrier Discharge Detectors. Introduction: This paper is a discussion of the dielectric barrier discharge detector. As such, it is intended to provide insight into the operating

More information

PNEUDRI High Efficiency Compressed Air Dryers.

PNEUDRI High Efficiency Compressed Air Dryers. PNEUDRI High Efficiency Compressed Air Dryers www.domnickhunter.com 1 PNEUDRI High Efficiency Compressed Air Dryers Compressed air plays an important role in modern industry. The decisions you make regarding

More information

SYNRAD Technical Bulletin # 0015d

SYNRAD Technical Bulletin # 0015d Page 1 of 6 SYNRAD Technical Bulletin # 0015d Technical Issue: Purge Gas Conditioning for f201/f400, i401, & p100/p250 Lasers Date: 30 July 2014 Description: This Technical Bulletin describes how to prevent

More information

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

V A C U U M A N D P R E S S U R E T E C H N O L O G Y Medical Air System Totally Oil Free ULTRAAR Series 4 EN ISO 7396-1 / HTM 0201 220V - 400V / 50Hz 60Hz SPECIFICATION ULTRAAR The ULTRAAR Medical Air System Totally Oil Free shall conform to ISO 7396-1 and

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

PNEUDRI High Efficiency Compressed Air Dryers

PNEUDRI High Efficiency Compressed Air Dryers PNEUDRI High Efficiency Compressed Air Dryers www.domnickhunter.com 1 PNEUDRI High Efficiency Compressed Air Dryers Compressed air plays an important role in modern industry. The decisions you make regarding

More information

clean and quiet laboratory

clean and quiet laboratory clean and quiet laboratory clean air for your lab JUN-AIR introduced the first compressor almost 50 years ago and started the development of the technology and design, which has made JUN-AIR compressors

More information

An ISO 9001 : 2008 Certified Company

An ISO 9001 : 2008 Certified Company NITROGEN TYRE AIR INFLATOR Model - FS 3500 TECHNICAL DETAILS Nitrogen purity Compressed air input range Nitrogen output N2 output pressure Nitrogen storage tank Motor power Motor voltage Weight Packing

More information

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular Desiccant Dryers Desiccant Dryers Heatless Heated Purge Blower Purge Modular Desiccant Air Dryers Quincy desiccant air dryers purify compressed air by adsorbing water vapor. Pressure dewpoints of -40 F

More information

DP 300 mobile dew point instrument

DP 300 mobile dew point instrument Instruction manual DP 300 mobile dew point instrument For measuring pressure, dew point and atmospheric dew point in different applications: Compressed air plants (refrigeration/ adsorption dryer) Granulate

More information

Process Gas Chromatograph

Process Gas Chromatograph Product Data Sheet RAI-PDS-GC-1000A June 2009 Model 1000A Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.

More information

Heatless Desiccant Compressed Air Dryers

Heatless Desiccant Compressed Air Dryers Heatless Desiccant Compressed Air Dryers Pro Dry Heatless Desiccant Compressed Air Dryer Inspired by its sophisticated predecessor, SMC can now boast an additional ten models to enhance the current Pro

More information

SAM-MAX Refrigerant Monitors

SAM-MAX Refrigerant Monitors SAM-MAX Refrigerant Monitors Monitor Refrigerants Including CFCs, HFCs and Ammonia Monitor Carbon Monoxide Exceeds ASHRAE 5-99 and USEPA 608 Monitoring Requirements Provide for Single or Multipoint Sampling

More information

QUINCY QOF SERIES OIL-FREE AIR COMPRESSORS QOF 2-30 HP

QUINCY QOF SERIES OIL-FREE AIR COMPRESSORS QOF 2-30 HP QUINCY QOF SERIES OIL-FREE AIR COMPRESSORS QOF 2-30 HP QOF 2-30 OIL-FREE SERIES OIL-FREE COMPRESSORS Industries such as pharmaceuticals, biotech, lab/ research, food and beverage, electronics and textiles

More information

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature 40-95 F Humidity < 80 % Particulates Pressure Gas and Noxious Vapors < 0.14 mg/scf 14.7 PSI NO ELECTRICAL DATA Mains voltage 400 Vac ± 10 % Frequency

More information

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm) -Series ultra-high purity compressed air dryers Flow Capacity: 5-1900 Nm 3 /hr (3-1110 scfm) 1 2 3 -Series ultra-high purity compressed air dryers Flow Capacity: 5-1900 Nm 3 /hr (3-1110 scfm) 1 2 3 nano-porous

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the GC 866 PID airtoxic (Model A73022) manufactured by: Chromatotec / airmotec 15, Rue d Artiguelongue Saint -Antoine 33240 Val de Virvée France has

More information

PNEUDRI MiDAS - Mini Dry Air System

PNEUDRI MiDAS - Mini Dry Air System PNEUDRI MiDAS - Mini Dry Air System The problem Compressed air is an essential power source that is widely used throughout industry. This safe, powerful and reliable utility can be the most important part

More information

www.compressedairsystems.com PURIFICATION SOLUTIONS D-Series1 ultra-high purity compressed air dryers flow capacity: 3-177 scfm (5-301 Nm /hr) 3 D 1 D-Series 1 ultra-high purity compressed air dryers D

More information

HPLC Column Ovens and Temperature Controllers

HPLC Column Ovens and Temperature Controllers HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures

More information

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw) Ingersoll Rand Rotary Screw Air Compressors 5-15 hp (4-11 kw) A New Standard of Performance Ingersoll Rand Welcome to Ingersoll Rand s rotary air solutions, a new standard of performance. Achieve highest

More information

ENVAIR lab CO2 Tri-Gas Incubator

ENVAIR lab CO2 Tri-Gas Incubator ENVAIR lab CO2 Tri-Gas Incubator Laboratory Incubator ENVAIR lab CO2 Tri-Gas Incubator Introduction ENVAIR lab Tri-Gas Incubator, providing precise temperature, C02, 02 control as well as high humidity,

More information

Chemtron Science Laboratories Pvt. Ltd.

Chemtron Science Laboratories Pvt. Ltd. Chemtron Science Laboratories Pvt. Ltd. To, INTRODUCTION TO CSL GAS CHROMATOGRAPHS COMPANY PROFILE Chemtron Science Laboratories Pvt. Ltd. is an ISO 9001: 2000 by BSI, a part of fastest growing industry

More information

Technical Specification

Technical Specification Technical Specification Medical Air Plant Product Description The CPX medical air plant shall fully comply with the United Kingdom Department of Health (DoH) HTM02-01, HTM2022 and NHS Model Engineering

More information

Automatic Isokinetic Sampler ST5

Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Description The ST5 is the next generation isokinetic sampler, developed to be efficient, rugged, accurate and user friendly. The perfect

More information

GAS ANALYSIS / DETECTION Gas Detector

GAS ANALYSIS / DETECTION Gas Detector Eikon - Single gas recyclable personal monitor GAS ANALYSIS / DETECTION Tough and rugged Eikon is the durable single gas fixed life personal monitor that really lasts the course. Loud & Clear Alarms Easy

More information

intrinsically safe detector for hydrocarbon gases

intrinsically safe detector for hydrocarbon gases portable flame ionisation detector intrinsically safe detector for hydrocarbon gases Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations

More information

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction BST-MG08/09 Multi-gas Detecting Alarm Manual Instruction 1. Application: This product is designed to ensure safety for users who work in dangerous places. It s used for detecting CO, O2, H2S, CH4 simultaneously

More information

Waveguide Dehydrators

Waveguide Dehydrators Waveguide Dehydrators Clean & Dry Air For Clear Communications Rugged & Reliable Compressed Air Systems for: TV and Radio Broadcast Applications Satellite Radar Aerospace Telecommunications Military Custom

More information

DISSOLVED GAS ANALYZER (DGA)

DISSOLVED GAS ANALYZER (DGA) DISSOLVED GAS ANALYZER (DGA) ONE INCH FORWARD After three years of successful operation of inch energy, we are here to contribute the nation growth by making the things indigenous Following the path of

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Nitrogen Generation Systems Compressed Air Dryers

Nitrogen Generation Systems Compressed Air Dryers Nitrogen Generation Systems Compressed Air Dryers Balston Compressed Air Dryers Balston offers both membrane and PSA technology. Balston Membrane Air Dryers combine superior coalescing technology with

More information

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors Atlas Copco Stationary Air Compressors GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors Introducing the WorkPlace Air System The only compressed air system that can

More information

Oil-Free Compressors. Oil-Free Compressors. Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP

Oil-Free Compressors. Oil-Free Compressors. Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP Oil-Free Compressors Oil-Free Compressors Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP Quality Comes in All Shapes and Sizes But Just One Color. Pure Oil-Free Air. As there is no metal-to-metal

More information

Oil-Less Rotary Screw Compressors Variable Speed. Engineered to Save

Oil-Less Rotary Screw Compressors Variable Speed. Engineered to Save D15H RS D37H RS D50H SR D75H SR Oil-Less Rotary Screw Compressors Variable Speed Engineered to Save Oil-Less Rotary Screw Compressors The CompAir range of oil-less compressors can be relied upon to deliver

More information

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

BST-MG07 Multi-gas Detecting Alarm Manual Instruction BST-MG7 Multi-gas Detecting Alarm Manual Instruction 1. Application This BST-MG7 multi gas detecting alarm is applied to underground coal mine, petrochemical industry, municipal, environmental protection

More information

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for

More information

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System Simplicity Reliability Performance Stratum Automated VOC Sample Prep System The Stratum Purge and Trap Concentrator (PTC) is a sample preparation instrument used to remove Volatile Organic Compounds (VOCs)

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

Downstream Equipment. Intelligent Air Technology

Downstream Equipment. Intelligent Air Technology Downstream Equipment Intelligent Air Technology The Clean Air Solution The advanced range of CompAir inline equipment has been specially developed to meet the needs of modern manufacturing and processing

More information

Environmental.

Environmental. Environmental Walk-In / DRIVE-IN Chambers www.cszindustrial.com Environmental Walk-In Chambers Walk-In chambers are used for testing or storing products that require a large capacity chamber. Applications

More information

PNEUDRI MiDAS A totally clean and dry compressed air system (CDA)

PNEUDRI MiDAS A totally clean and dry compressed air system (CDA) PNEUDRI MiDAS A totally clean and dry compressed air system (CDA) www.domnickhunter.com 1 PNEUDRI MiDAS PNEUDRI MiDAS - Mini Dry Air System The Problem Compressed air is an essential power source that

More information

OIL FREE COMPRESSED AIR Piston, Scroll & Screw Compressors 55 L/min to 42,763 L/min 2 Cfm to 1510 Cfm

OIL FREE COMPRESSED AIR Piston, Scroll & Screw Compressors 55 L/min to 42,763 L/min 2 Cfm to 1510 Cfm OIL FREE COMPRESSED AIR Piston, Scroll & Screw Compressors 55 L/min to 42,763 L/min 2 Cfm to 1510 Cfm Compressed air for Dental, Medical, Pharmaceutical, Food Preparation and Processes where oil free air

More information

Atlas Copco. Refrigerant Air Dryers FX Hz

Atlas Copco. Refrigerant Air Dryers FX Hz Atlas Copco Refrigerant Air Dryers FX1-21 60 Hz Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational capacity.

More information

Enclosed Scroll Air Compressor System SES 3-5 HP

Enclosed Scroll Air Compressor System SES 3-5 HP Enclosed Scroll Air Compressor SES 3-5 HP Specification General The Powerex Enclosed Scroll Air Compressor unit is designed to provide clean, dry air for industrial applications where the quality of the

More information

Hydrogen Generator Model HPNM 2

Hydrogen Generator Model HPNM 2 Hydrogen Generator Model HPNM 2 MATHESON TRI-GAS 166 Keystone Drive Montgomeryville, PA 18936 Phone: 215-641-2700 Fax: 215-619-0458 Email: mtgmmville@matheson-trigas.com Introduction Index INDEX... 2 INTRODUCTION...

More information

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency Titus Air Systems TDD Series The Company Since 1986, our company has been known for delivering high quality compressed air and gas system solutions. In moving from being a local sales and service provider

More information

Process Gas Chromatograph

Process Gas Chromatograph A I T Applied Instrument Technologies FXi Series5 PRODUCT SPECIFICATIONS Process Gas Chromatograph PSS FXI-S5 The FXi Series5 Process Gas Chromatograph (PGC) continuously analyzes, measures, and reports

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

The leader in gas dehydration & filtration

The leader in gas dehydration & filtration The leader in gas dehydration & filtration wellhe ad production instrument and fuel gas l andfill & digester gas coal-bed methane off shore Van Gas Technologies specializes in natural gas and biogas dehydration

More information

Oil-Less Rotary Screw Compressors

Oil-Less Rotary Screw Compressors D15H (RS) D37H (RS) Oil-Less Rotary Screw Compressors D50H SR D75H SR Intelligent Air Technology Oil-Less Rotary Screw Compressors The CompAir range of oil-less compressors can be relied upon to deliver

More information

High quality compressed air from generation to application

High quality compressed air from generation to application 01 02 Introduction High quality compressed air from generation to application aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing &

More information

Clean, Dry Air System

Clean, Dry Air System C O M P R E S S E D A I R Clean, Dry Air System Moisture, Oil and Particulate Contamination Removal Sullair SMC Solves the Problem Sullair SMC air dryers. Your compressed air system will contain water,

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter by Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Technical Specifications Brouwer -86 o C Chest STORAGE SPECS UNIT -86 DFC 370-86 DFC 620-86 DFC 820 Capacity L 370 620

More information

New standard in compressed air treatment, providing Energy Savings up to 99%

New standard in compressed air treatment, providing Energy Savings up to 99% PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

931D Style B Process Gas Chromatograph

931D Style B Process Gas Chromatograph Product Specifications PSS 6-4N1 D 931D Style B Process Gas Chromatograph The new 931D Style B Process Gas Chromatograph continuously analyzes, measures and reports the concentration of components in process

More information

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

Technical specifications of FT-IR Spectrometer

Technical specifications of FT-IR Spectrometer Technical specifications of FT-IR Spectrometer We would like to buy a FT-IR spectrometer which has to be integrated with a Gas Chromatograph with the following technical specifications. 1. The spectrometer

More information

Atlas Copco. Refrigerant air dryers FX 1-21 ( l/s, cfm)

Atlas Copco. Refrigerant air dryers FX 1-21 ( l/s, cfm) Atlas Copco Refrigerant air dryers FX 1-21 (7-1236 l/s, 1-2516 cfm) Air treatment a smart investment Why invest in dry quality air? Wherever you go in the world, whatever application you look at, you will

More information

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range Moisture Sensors DP & Rh The basic low cost solution With a wide range Moisture technologies and their ranges DEW-POINT SENSOR TRAINING No single technology can cover the entire range All have limitations

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the 3000HM Flame Ionisation Detector 3010 & 3030 Portable Flame Ionisation Detector manufactured by: Signal Group Ltd 12 Doman Road Camberley Surrey,

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS ANALYTICAL TECHNOLOGIES VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Portable, integrated battery for 6 hours

More information

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr) snowstorm filled ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2 3 ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2

More information

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm) Atlas Copco Heat-of-compression rotary drum dryers ND series (1000-2500 l/s, 2290-5297 cfm) Cost-effective dry air for your application Dry and clean compressed air is essential for a broad range of industrial

More information

IAQ_100 C Package

IAQ_100 C Package 15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802 DESCRIPTION SPEC Sensors IAQ_100 is a Screen Printed ElectroChemical sensor component specifically designed for the broad detection of gases associated

More information

VHP ARD BIODECONTAMINATION SYSTEM

VHP ARD BIODECONTAMINATION SYSTEM VHP ARD BIODECONTAMINATION SYSTEM APPLICATION The VHP ARD Biodecontamination System is designed for portable biodecontamination* of clean, dry, sealed Enclosures.** The VHP 1000-ARD Biodecontamination

More information

Process Gas Chromatograph

Process Gas Chromatograph Product Data Sheet PDS 103-1000.A01 December 2005 Model 1000 Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.

More information

Spark Holland introduces

Spark Holland introduces BETTER SAMPLE CARE Spark Holland introduces ACE Absolutely unique: on-line SPE with Automated Cartridge Exchange Spark Holland introduces ACE Absolutely unique: on-line SPE with Automated Cartridge Exchange

More information

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES L i t r o n T o t a l L a s e r C a p a b i l i t y Setting the New Standard in Chiller Technology ±0. C ZEROPOINT CHILLER SERIES Litron s Zeropoint Series Setting the New Standard in Advanced Chiller

More information

Ultra low temperature freezers. -40 C and -86 C. Green Line

Ultra low temperature freezers. -40 C and -86 C. Green Line Ultra low temperature freezers -40 C and -86 C Green Line by by Ultra low freezer series Brouwer ultra low temperature freezers are available in two temperature ranges: -40ºC and -86ºC. The standard internal

More information

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

Vacuum Oil Purifier (VOP) (5 Pages. June 2017) Vacuum Oil Purifier (VOP) (5 Pages. June 2017) The best designed Vacuum Oil Purifier made, combining simple operation with higher performance, creating more value for your investment. 1. 304 Stainless

More information

Adsorption Air Dryers

Adsorption Air Dryers Adsorption Air Dryers ADS 1 to 215 Clean and dry air. Prevent the risks, enjoy the benefits. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY PARTNERSHIP

More information

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview System Overview The SRI CryoSulfur GC comes with everything you need to detect low-level sulfur compounds in gas samples. Since some sulfur compounds do not trap well, the CryoSulfur GC uses the CryoCooler

More information

Global Series Screw Air Compressors Life source of industries

Global Series Screw Air Compressors Life source of industries Global Series Screw Air Compressors Life source of industries 125-200 HP series Global Series Elgi, established in 1960, designs and manufactures a wide range of compressors. The company has gained its

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

CMMD Series Membrane Air Dryer

CMMD Series Membrane Air Dryer CMMD Series Membrane Air Dryer NEW Engineered to Save CMMD Series Compressed Air Dry Air Membrane Drying CompAir s CMMD Series membrane air dryer offers a pointofuse alternative for low dew point applications

More information

continuous emissions monitoring Combustion & Environmental Monitoring

continuous emissions monitoring Combustion & Environmental Monitoring continuous emissions monitoring Combustion & Environmental Monitoring Advanced CEM technology for accurate measurement and high reliability - to meet today s regulatory requirements and ready for future

More information

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1 ARES-G2 Rheometer Site Preparation Guide A Issued June 2016 1 1 A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility

More information

TPF Series Ozone Generators

TPF Series Ozone Generators TPF Series Introduction The model TPF is modular series of medium frequency ozone generators employing the latest electronics. The generators are manufactured by Ozono Elettronica Internazionale (OEI)

More information