1 Installation Guide Tower and Draft Arm Dispenser System Start-up Video (Remote Cooler): Start-up Video (Ice Maker): SodaParts.com - All rights reserved.

2 Table of Contents 1. Preparing for Installation 1.1 Unpacking & Inspection 1.2 Selecting Remote Cooler Location 1.3 Tools Needed 2. Water Supply 2.1 Volume, Pressure, & Quality 2.2 Connecting the Water Supply 3. Installing the Components 3.1 Installing the Dispenser 3.2 Installing the Cooling Device 3.3 Connecting the CO 2 Supply 3.4 Connecting the Syrup Supply 4. Start-up Procedures 5. Sanitation 6. Troubleshooting

3 Preparing for Installation Chapter 1 3

4 1.1 Unpacking & Inspecting Upon receiving your system remove it from the shipping carton or pallet. Required Items & Parts Cooling Device Unpack all parts. Make sure all required items and parts listed (left) are present and in good condition. If any parts are missing or damaged, notify our office immediately. Optional Items Not included in seltzer-only systems 4

5 1.2 Selecting Remote Cooler Location (If you re using another cooling method, skip to Section 1.3) Consider positioning cooling unit as close as possible to your electrical source or receptacle. Allow a minimum of 2 space between remote cooler and cabinet walls or top for sufficient space for ventilation. Excessive heat in a storage cabinet will prematurely melt the ice and cause the cooling unit to labor excessively. Ambient temperature for your cooling system should not exceed 100 degrees F. Operation of the cooling unit in temperatures exceeding 100 degrees can & will cause early cooling unit failure and produce poor drink quality. Allow enough space on the top of remote for lid opening. Enough space must be allowed to install the remaining support equipment for your system. Co2 tank, syrup boxes, carbonator, syrup pumps & regulators. Note: If you are planning on installing the cooling unit in a small enclosed area with poor air circulation, consider installing a vent in the cabinet wall to allow for adequate heat dissipation. 5

6 1.3 Tools Needed 1. Pliers 2. Flathead Screwdriver 3. Crescent Wrench A bucket and rag are also useful to have, if needed. 6

7 Water Supply Chapter 2 7

8 2.1 Volume, Pressure, & Quality Since a soft drink is approximately 5 parts water to 1 part syrup, having an adequate, clean water supply is absolutely essential. There are 3 important areas of focus with your water supply: 1. Volume The inside diameter of your main water supply tubing must be a minimum 1/4 if connected to your water source within 10 of the carbonator. If your carbonator is more than 10 away from the water source, a minimum 3/8 inside diameter is required. Anything less then this will starve the carbonator pump and create noise within the pump, poor carbonation, and cause premature failure of the carbonator. Do NOT use ice maker tubing! Food grade braided nylon, copper, or stainless tubing is acceptable for your main water supply. 8

9 2. Pressure High water pressure affects the carbonators ability to carbonate properly. Ideal water pressure range is psi. If water pressure exceeds 55psi, the carbonator will NOT carbonate properly. Water pressure above 55psi. (most city water is above 55psi.) will require a water pressure regulator. If the water pressure is irregular or below 35psi. a water booster will be necessary. 3. Quality Mineral deposits & sediment (found in most city water supplies) get caught in the carbonator rotary vane pump, and in the check valves as well as other areas of the system causing leaking and or failure. A water filter is recommended to remove unwanted silt, sand, smells, & other undesirables. This will give the highest quality product results as well as lengthen the life of your soda system. 9

10 When a water filter is used, it is important that it has a flow rate of 100 gallons per hour and MUST be flushed BEFORE it is connected to the soda system. 2.2 Connecting the Water Supply Cartridge and Inline water filters NOTE: Water supply should be connected pre-water softener, not post. Using softened water will adversely affect carbonation. The main water connection on your system is clearly tagged. Your water supply line will run to the carbonator pump. We use a 3/8 fitting (not metric) for this connection. NOTE: If you have a non-carbonated flavor or plain water coming from your dispenser, you will need to tee your main water supply. Once you have established your water supply source, it is important to thoroughly flush this line for a few seconds of any debris, scale, mineral deposits, and any other impurities that may be in the lines. The smallest amount of debris can easily get lodged in a check valve or in your dispenser causing dripping, leaking, and failure. NOTE: Water connections directly connected to potable water supply should be sized, installed & maintained according to federal, state, & local laws. 10

11 Installing the Components Chapter 3 11

12 3.1 Installing the Dispenser Tower Installation There are a couple different ways to install your counter top tower. Your must decide which way is best to run your product tubing and wiring for the transformer. You have access through the bottom of the tower to go through an opening in your counter. There is also a removable cover at the bottom rear of the tower for routing the tubing & wiring strait out the back. The transformer will need to be plugged in to your wall outlet to operate the valves. The most common way is to mount the base of the tower to your desired counter top using a bead of clear silicone. There is a ½ inch flange located on the bottom of the tower if you require a more secure install. You can drill through the flange to anchor your 12

13 tower with fasteners of your choice. The drip tray can be emptied or cleaned by removing the cup rest and wiping the tray of spills & drips. The second most common method of tower installation is tracing the shape of the tower & drip tray on to a piece of wood or plastic and cutting it to size. Secure cut material with clear silicone to base of tower. This cut out will act as a foot adding stability while still allowing you to move the tower. Draft Arm Installation There is a threaded shank located at the base of the draft arm. It is used to secure the dispenser through a hole in your counter top and secured with the nut & washer provided. The drain tray will also need to be secured via the threaded shank in a like manner. 13

14 3.2 Installing the Cooling Device If your system is cooled by a remote cooler (right), you will have two sets of lines coming out of the remote. The insulated lines will go to your dispenser or soda gun. The non-insulated lines that are shown below come from the syrup pumps and water supply. These lines will be labeled and will be discussed further in the remaining installation chapters. 14

15 If your system is cooled by a cold plate (right), you will have two sets of lines coming out of it. The insulated lines will go to your dispenser or soda gun. The non-insulated lines come from the syrup pumps and carbonator, so you will need to attach them to the syrup pumps and carbonator. You will need to install the cold plate in an ice bin or igloo cooler. 3.3 Connecting the CO 2 Supply 1. Place CO 2 cylinder where it can be easily retrieved for refilling. Secure the tank with a safety chain to prevent the tank from falling over. 2. Connect primary CO 2 regulator to CO 2 cylinder. Use a fiber or plastic washer between the primary nut & stem and the tank neck (right). 15

16 3. Tighten the CO 2 nut on the regulator with an adjustable wrench. If you have separate primary & secondary regulators (left) with your system go to step #4 If you have a triple gauge regulator (right) skip to: Triple Gauge Regulator Installation 4. Using the ¼ high pressure tubing, attach the ¼ swivel nut that is marked to primary regulator gas out to the bottom of the regulator. Make sure the white nylon flare washer is between the swivel nut and the brass flare fitting located on the bottom of the primary regulator. 5. Tighten the swivel nut with an adjustable wrench. 6. Locate where you want to mount the secondary regulator and syrup pumps. 16

17 7. Attach the CO 2 tubing swivel nut end that reads to secondary regulator gas in to the right male flare fitting on the secondary regulator. Make sure white flare washer is installed before connecting. Tighten swivel nut with adjustable wrench. 8. Attach the remaining swivel nut end of the CO 2 line that reads to carb tank CO 2 gas in to the carbonator tank. Make sure white flare washer is installed before connecting. Tighten swivel nut with adjustable wrench. WARNING: DO NOT TURN ON THE CO 2 SUPPLY AT THIS TIME Triple Gauge Regulator Installation Triple gauge regulators are both primary & secondary regulators attached together. You will have two separate CO 2 gas lines for this type of regulator. Attach the swivel nut on the CO 2 line that reads to primary 17

18 regulator gas out to the brass male flare fitting on the bottom of the primary regulator. White flare washer MUST be installed between these two fittings. Tighten swivel nut with wrench. Attach swivel nut on the opposite side of the CO 2 line that reads to carb tank CO 2 gas in White flare washer MUST be installed between these two fittings. Tighten swivel nut with wrench. Attach the swivel nut on the CO 2 line that reads to secondary regulator gas out to the brass male flare fitting on the bottom of the secondary regulator. White flare washer MUST be installed between these two fittings. Tighten swivel nut with wrench. Attach swivel nut on the opposite side of the CO 2 line that reads to syrup pump CO 2 gas in White flare washer MUST be installed between these two fittings. Tighten swivel nut with wrench. WARNING: DO NOT TURN ON THE CO 2 SUPPLY AT THIS TIME 18

19 3.4 Connecting the Syrup Supply Bag-N-Box is a plastic bag filled with syrup encased in a box. There is a connection receiver at one end of the bag. A syrup pump with a clear piece of tubing with a bag in the box connector attached to it is connected to the receiver. (see picture below) Syrup is pumped out of the bag, moves through the syrup pump and is pushed toward the dispenser. There are different style connectors for different manufacturer s products. 19

20 Pump Operation The syrup pump is propelled by gas (or air) pressure. The pressure of the syrup leaving the pump is equal to the gas pressure feeding or driving the pump. The pump will continue to run until the pressure of the outbound syrup is equal to the inbound gas pressure. When the pressure drops in the syrup line to the dispensing valve, the pump will activate and 20

21 continue until the pressure is equalized. This will happen almost every time a drink is poured from the valve. Installing Bag-In-Box Syrup Pumps 1. Place your syrup boxes as close as possible to the syrup pumps. Under 10 feet is ideal. 2. Mount syrup pumps to your desired location. 3. Uncoil syrup line tubing from cooling device to the syrup pumps. 4. Connect the syrup pump fitting on each line to each pump. (See pictures of pump types below) 21

22 5. Attach each syrup pump bag in box connector to each syrup box. 6. If you DO NOT have all of syrup boxes (1 for each syrup pump) disconnect the gas CO2 fitting from the pump so it does not activate that pump when you start the system. Allow it to dangle loosely. 22

23 Tower and Draft Arm Start-up Procedures Chapter 4 Start-up Video (Remote Cooler): Start-up Video (Ice Maker): 23

24 If you have a remote cooling system, conduct the following start-up procedures: Otherwise, skip to step #7 1. Lift the lid and find labeled water fill line. 2. Fill to labeled water fill line located on the bottom right side of the water bath ice bin. 3. Plug the cooler into your power supply. 4. Press the Select button until the middle light (medium) turns on. 24

25 5. Press the Start button 6. Allow the machine to harvest ice for the next several hours. Standard Cold Plate Cooling Start-up 7. Y ou will need to set up your cold plate to be immersed in ice. There is a variety of options to set this up. Any type of container that will allow you to cover your cold plate with ice will work. Ice on the cold plate is necessary only when all of the support 25

26 equipment is assembled and you are ready to start dispensing product. Standard Carbonator Start-up 8. Turn water supply to the carbonator ON. Water supply tubing and valve are not included, so your water supply connection may look different than this picture. 9. Start filling carbonator tank by releasing the pressure relief valve located on top of carbonator tank (see figure #1). This will allow air to escape while the tank fills with water. Hold pressure relief valve open until water spurts out of valve opening. Figure #1. 26

27 10. Close pressure release valve. 11. Check for water leaks. Inspect all connections where water is run (example: carbonator, soda fountain or gun, all tubing lines carrying water). 12. Plug carbonator in to power source. Do NOT expect the carbonator to start running because it is already full of water. Only after dispensing soda water will the float in the tank sense the water level drop and activate the motor and pump. This procedure will be performed later. CO 2 Gas Introduction 13. Prepare for CO2 gas introduction to the system. Make sure the adjusting screw (see figure #2) & screw lock nut (see figure #3) are not tightened but are unscrewed and loosened. Figure #2. 27

28 This is performed by turning them in the counterclockwise direction. This allows you to introduce the gas in stages. 14. Turn CO2 tank valve on. Turn in counter clock wise direction. Figure # Set adjustment on primary regulator by turning adjusting screw in the clock wise direction until needle on primary dial reads 100 psi. Figure # Check for CO2 gas leaks by spraying all connections where gas runs through tubing with a spray bottle filled with a mild dish detergent mixture (1/2 water & 1/2 detergent). If leaks are found (bubbling; see figure #4), make necessary adjustments to clamps or fittings until bubbling stops (see figure #5). Tighten lock nut. Figure #5. 28

29 Do NOT adjust secondary regulator, yet! 17. Purge air from tubing by activating each valve separately. 18. Recycle carbonator allowing the proper blend of gas & water levels in the carbonator tank by dispensing soda water from one of the valves (see figure #6) until carbonator motor (see figure #7) starts. Spitting or erratic water flow is normal while air purges from the system. STOP dispensing water until carbonator finishes recycling (motor turns off). Figure #6 Figure #7. NOTE: Normal carbonator recycling does not exceed 60 seconds. If your carbonator is taking longer than 1 minute to recycle (motor turns off), unplug it immediately! 29

30 Perform recycling process 3 times. By the 3rd time you will notice a strong effervescence (bubbling) in the water. You are now ready to introduce syrup to the system. NOTE: ALL syrup pumps must be attached to a bag in box syrup before allowing them to be started. If you do NOT have a syrup box attached to each syrup pump you MUST disconnect the fitting that supplies gas to the pump (see figure #9). 19. Turn screw on the secondary regulator clockwise to allow gas to pass and be sent to drive the syrup pumps (figure #8). While turning the screw you Figure #8. will see the needle on the dial rise. As the pressure rises you will begin to hear popping coming from the syrup pumps signifying their activation. You will also see syrup moving from the syrup box up the BIB tubing towards the syrup pump. Continue adjusting regulator to 55 psi (20 psi for draft arms - See page #36) 30

31 NOTE: Syrup pumps DO NOT continually run endlessly, they will push syrup to your dispenser and stop when pressure you have set the secondary regulator to has been achieved. If your syrup pump does NOT shut off after a minute of setting your secondary regulator, disconnect the syrup pump that is continually running by removing the gas fitting from the active pump (see figure #9). Figure #9. Before After Figure #10. Activate each flavor to allow syrup to flow. You will hear the syrup pumps popping during this process (see figure #10). 31

32 20. Adjust each flavor for proper syrup and water (carbonated or plain) ratio. This can be done to taste or with a brix kit. Adjusting screws for syrup and soda water are found on the black triangular manifold. Adjusting Syrup to Soda Water Ratio (Brixing) Brixing Standard Soda Fountain Dispenser Valves Adjust each valve for proper syrup & water (carbonated or plain) ratio. This can be done to taste or with a brix kit. Remove each valve cover to expose adjusting screws for syrup & soda water. Flomatic valve 32 Cornelius UF-1 valve Lancer valve

33 Left side adjustment is for soda water or plain water the right side is for syrup increase or decrease. Detailed Flomatic Valve Brixing Instructions Two simple adjustments are all you need to brix the Flomatic valves. You will need a Flomatic S tube syrup separator, 5/32 inch hex wrench, watch and brix cup. Place the S-tube syrup separator over the syrup diffuser and you are ready to begin. You need not remove the nozzle. Clock-wise movement of the brix nut adjustment screw increases the flow rate and vice versa. Restrict the flow by withdrawing the brix nut adjustment screw as far as it will go (turn counterclock-wise). At this point the flow will be at a minimum. The 424 or 324 ceramic flow controls can be adjusted from 1.5 oz. /sec. to 3.0 oz. /sec. Turn the soda brix nut adjustment screw five full turns clock-wise and the flow rate should be close to 2.5 oz/sec. You will need to fine tune from there. For fast flow, 33

34 continue adjusting the valve until you get 7.5 oz. of soda in 3 seconds. Once the soda flow rate is set, then establish the syrup ratio in exactly the same way. The 464GP ceramic flow controls can be adjusted from 2.0 oz./ sec. to 4.0 oz./sec. Turn the soda brix nut adjustment screw five full turns clockwise and the flow rate should be close to 3.0 oz./ sec. You will need to fine tune from there. For fast flow, continue adjusting the valve until you get 9.0 oz. Of soda in 3 seconds. Once the soda flow rate is set, then establish the syrup ratio in exactly the same way. Most brix cups are calibrated for a standard brix ratio. Adjust the syrup flow with movement of the adjusting screw until the desired ratio is established. Some Flo-matic valves are equipped with a flow washer on the water side instead of flow controls. In that case, it is not necessary to set the flow rate. Simply set the syrup ratio and you are done. Flomatic juice valves may combine with a flow washer on the water side. The syrup side may be manufactured with a flow control or metering screw. The metering screw turns clockwise to close and counter clockwise to open. The screw does not have a stop; be sure not to withdraw completely when under pressure. 34

35 Brixing Draft Arm Dispensers 1. Remove the black nozzle on the head of the draft arm. 2. Unlock the lock nut by using an adjustable wrench to turn it clockwise (right). This will allow you to turn the syrup tube. 3. Screw the syrup tube (right) all the way in (clockwise) and then back it out (counterclockwise) 1 ¾ - 2 full turns. This should give you the proper syrup flow. If the syrup needs to be increased, screw the syrup tube in ¼ turn (clockwise). Turn the syrup tube out (counterclock wise) to decrease the flow of syrup. 35

36 Fine adjustments should be made with the soda water or plain water adjusting screw, which is the flat head screw on the front of the draft head. Remember, these types of dispensers run best on very low syrup pump pressure (start at 20 psi. on your secondary regulator). Sweetness can also be adjusted by the increase and decrease of the syrup pump pressure. 36

37 Sanitation Chapter 5 37

38 Prepare a large bucket with warm to hot tap water. Mix sanitizer packet (1 packet to each 2 ½ gallons of water) You may also use liquid bleach (unscented) ¼ oz. bleach to each gallon of water. If you have Coke or Pepsi bag in box connectors (right), you will need to open the spring loaded safety valve to allow liquid to draw through the bag in box connector. Pepsi and Coke BIB connectors You can also remove the syrup BIB connector from the clear suction hose on the syrup pump to allow sanitizer to pass. Reconnect BIB connector with a standard worm clamp at the completion of sanitizing. 38 If you have the grey generic style connectors, you can remove the tan cap (right) to allow sanitizer to pass.

39 If you have access to an empty syrup box, cut the bladder connect off (see pictures below). This will allow you to attach it to your BIB connect during flushing & sanitizing. Put each syrup pump suction hose in the sanitizing solution and activate dispenser until sanitizer flows freely from the nozzle. 39

40 40

41 Troubleshooting Chapter 6 41

42 PROBLEM QUESTION SOLUTION Nothing happens when the beverage valve is activated Only syrup is dispensing from the valves Only water is dispensing from all valves Is the transformer plugged in? Is there power to the electrical outlet? Is the valve switch defective? Is the valve properly connected? Is there product going to the beverage valve? Is the carbonator plugged in? Is the water supply turned on? Is the CO 2 supply on? Is the CO 2 pressure set correctly? Is an obstruction in the water line? Are the water lines connected properly? Do you have enough CO 2 gas in the CO 2 tank? Do you have syrup? Are system pressures set correctly? Are the syrup connectors properly connected? Plug into transformer receptacle Restore power to the outlet Check and replace the valve switch Ensure power wires to the switch are connected Turn ON the valve backblock shut-off Carbonator must be plugged in The minimum water supply must be provided PSI Check the CO 2 tank to see if it is turned on. If it is, replace or refill it. The CO 2 pressure to the carbonator must be set between PSI. Check and set all system pressures to the correct settings. Remove the obstruction Reconnect the water lines correctly Replace or refill CO 2 tank Check and replace any empty boxes of syrup Adjust and reset pressures to their proper settings Remove the connectors and properly reinstall them 42

43 PROBLEM QUESTION SOLUTION Only water is dispensed at one or two valves Poor carbonation Is an obstruction in the water line? Are the water lines connected properly? Is the backblock shut-off closed? Is electricity getting through the valve solenoid when energized? Are the connectors to the syrup clean and properly attached? Is the syrup system obstructed or lines installed improperly? Do you have a full box of syrup? Are the Bag-in-Box (BIB) syrup pumps operating? Are your syrup lines hooked up and unobstructed? Is CO 2 pressure to the carbonator properly set? Is the carbonator air locked (all CO 2 and no water in the tank)? Is the inlet water pressure to the carbonator above the maximum 50 PSI? Is the carbonator inlet water temperature too high? Remove the obstruction Reconnect the water lines correctly Check the backblock shut-off behind the valve. If it is closed, open the backblock. Repair or replace the wiring or solenoid coil Clean the syrup connector and correctly attach the connector to the syrup connector Reconnect the lines properly or remove the obstruction to allow syrup to flow. Replace if necessary Check all connections Check syrup out lines designated for these valves The CO 2 pressure to the carbonator must be set between PSI. Check and set all system pressures to the correct settings. Turn off carbonator and CO 2. Release vent on the tank until water comes out. Turn carbonator and CO 2 on. Minimum inlet water pressure is 35 PSI 50 PSI maximum. Install water regulator or booster pump to maintain proper pressures. Inlet temperature of the water to the carbonator should be no more than 74 degrees Fahrenheit Continued on next page... 43

44 PROBLEM QUESTION SOLUTION Poor carbonation (continued) Do you have CO 2 gas? Replace or refill CO 2 tank Beverage tastes weak Is the dispensed beverage temperature warm? Is the under-counter ice maker (if equipped) operating properly? Is the remote cooler (if equipped) operating properly? Is ice in the cup? Is there any residue of cleaning agents (dish detergent) in the cup? Do you have enough CO 2 to run the syrup pumps? Are your system pressures set correctly? Do you have a sufficient supply of syrup? Is the brix of the valve set correctly? Lower beverage temperature to degrees Fahrenheit (see pages 44-45) Ensure cold plate is completely covered with ice - Check if ice bank has formed around remote cooling lines - Check for proper water level - Check power to refrigeration deck Ice to your carbonated beverage is necessary to maintain optimum beverage quality Any type of cleaning detergent residue will reduce product quality Check amount of CO 2 in tank Replace or refill our CO 2 supply Check and correctly set all system pressures Replace empty syrup containers Brix all beverage valves Beverage tastes sweet Is the brix of the valve set correctly? Brix all beverage valves Beverage has an off-taste Is the brix of the valve set correctly? Brix all beverage valves Beverage valve does not maintain brix Is the syrup supply fresh? Is the water supply filter fresh? Is water supply tubing from main water supply NSF and non-toxic? Are the CO 2 system pressures correct? Most syrups should be used within 90 days of the manufacturer Change the filter Use only NSF certified and nontoxic food grade nylon, copper, or stainless tubing for your main water supply Check and adjust any pressures and inconsistent regulators Continued on next page... 44

45 PROBLEM QUESTION SOLUTION Beverage valve does not maintain brix (continued) Unusual amount of foaming of finished product The beverage valve continues to operate after released Is the BIB syrup pump holding pressure? Are incoming water pressures constant? Is drink being drawn correctly? Is the dispensing nozzle or valve dirty? Is soft water being applied to the system? Is the CO 2 system pressure to the secondary regulator high? Is the drink too warm? Is the valve lever (if equipped) sticking? Is the push button actuator sticking? Repair or replace BIB syrup pump Add water booster pump or water pressure regulator to maintain proper brix Make sure cup is tilted with product flowing down the inside of the cup Clean dispensing components Do not use carbonated softened water for beverage systems Reduce pressures to the recommended settings Make sure the cooling device is working and inlet temperature of the water to the carbonator does not exceed 74 degrees Fahrenheit Replace or adjust the beverage valve lever to correct Replace or adjust the beverage valve actuator Dispensed beverage is warm Is there ice on the cold plate? Be sure ice covers the entire cold plate give the cold plate time to cool Has ice bridged over the cold plate? Is the remote cooler or undercounter ice maker plugged in or turned on? Does the system beverage temperature increase significantly between cooling point and dispensing point? Is electric power supplied to the receptacle or refrigeration system? Is the cooling system operating properly? Push ice down to ensure ice covers and contacts the entire cold plate Plug in (or turn ON) the refrigeration system Locate source of heat gain repair or replace the cause of added heat Restore power to the receptacle or refrigeration system Repair or replace the cooling system Continued on next page... 45

46 PROBLEM QUESTION SOLUTION Carbonator does not operate BIB syrup pump will not start BIB syrup pump operates but does not pump syrup BIB syrup pump does not supply enough syrup Is the main water supply pressure too high? Is the water turned on and the CO 2 gas pressure set between PSI? Is electric power supplied to the carbonator? Is the water level or float control of the carbonator operating properly? Is the inlet water pressure to the carbonator above the maximum 50 PSI? Do you have syrup connected to the inlet hose of the pump? Is syrup out tubing kinked or obstructed? Is the connector to the Bag-in-Box syrup properly connected? Is the CO 2 supply interrupted? Is the gas pressure to the pump correctly set? Is a beverage dispensing valve open? Is the BIB syrup pump air locked? Is the syrup BIB connector properly connected? Is the tubing from the BIB syrup box to the pump full flow and not kinked? Are the gas or air pressures supplied to the pump correct? Water supply pressure must be between PSI Restore CO 2 supply to the carbonator within proper limits Restore electricity to the outlet that supplies the carbonator with power Repair or replace according to instructions provided by the carbonator manufacturer Minimum inlet water pressure is 35 PSI 50 PSI maximum. Install water regulator or booster pump to maintain proper pressures. Replace syrup box Remove the obstruction or straighten the line Remove and properly reconnect the BIB connector Check CO 2 supply Replace, refill, or turn on if necessary Adjust gas pressure to the recommended setting for the product Make sure CO 2 fitting is properly inserted Open beverage valve to allow syrup to flow through the system Make sure BIB pumps are installed with the outlet port on top Remove and correctly reconnect the BIB connector to the BIB container Remove/repair kink or replace hose Check and correct any incorrect gas or air pressures 46

TRAINING OUTLINE POST-MIX DAILY MAINTENANCE

TRAINING OUTLINE POST-MIX DAILY MAINTENANCE TRAINING OUTLINE POST-MIX DAILY MAINTENANCE 1. System Types A. Post-Mix a. Countertop b. Ice-Cooled c. Remote with Tower B. Pre-Mix a. Countertop b. Ice-Cooled c. Remote with Tower 2. Check CO2 A. Check

More information

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER Operators Manual Release Date: June 10, 2013 Publication Number: 741200028OPR Revision Date: May 9, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com

More information

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123 Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123 Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.com

More information

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSER ICE/BEVERAGE DISPENSER MODEL: ENDURO-175 8 VALVE OPERATOR S MANUAL Release Date: March 1, 2004 Publication Number: 620917901OPR Revision Date: August 3, 2010 Revision: C Visit the IMI Cornelius web site

More information

TROUBLESHOOTING VANGUARD

TROUBLESHOOTING VANGUARD TROUBLESHOOTING VANGUARD IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring. WARNING: Disconnect electrical power to the Unit to prevent personal injury

More information

UC300. INSTALLATION & SERVICE GUIDE Part Number

UC300. INSTALLATION & SERVICE GUIDE Part Number UC300 INSTALLATION & SERVICE GUIDE Part Number Foodservice Group Manitowoc Beverage Equipment 2100 Future Drive w Sellersburg, IN 47172-1868 Tel: 812.246.7000, 800.367.4233 Fax: 812.246.9922 www.manitowocbeverage.com

More information

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve OPERATOR S MANUAL ICE/BEVERAGE DISPENSER Model: Enduro-175 8 Valve Release Date: March 1, 2004 Publication Number: 620917901OPR Revision Date: January 14, 2015 Revision: E Visit the Cornelius web site

More information

VFCB. Ice Frost 2 and 3 Bowl Post-Mix and 2 Bowl Pre-Mix. Installation, Service, and Operator s Manual

VFCB. Ice Frost 2 and 3 Bowl Post-Mix and 2 Bowl Pre-Mix. Installation, Service, and Operator s Manual VFCB Ice Frost 2 and 3 Bowl Post-Mix and 2 Bowl Pre-Mix Installation, Service, and Operator s Manual Release Date: April 19, 2004 Publication Number: M620919596OPR Revision Date: June 14, 2007 Revision:

More information

2323 Drop-in Dispenser with MVU

2323 Drop-in Dispenser with MVU 2323 Drop-in Dispenser with MVU Install, Program, Operate, and Service Bevariety TM Dispenser You must follow these instructions step by step as you complete the installation and programming of this dispenser.

More information

Installation/Service Manual VANGUARD 245 POST-MIX OVERCOUNTER DISPENSER

Installation/Service Manual VANGUARD 245 POST-MIX OVERCOUNTER DISPENSER IMI CORNELIUS INC www.cornelius.com Telephone (800) 238-3600 Installation/Service Manual VANGUARD 245 POST-MIX OVERCOUNTER DISPENSER IMPORTANT: TO THE INSTALLER. It is the responsibility of the Installer

More information

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower Installation, Care and Use of Your Lynx Beverage Tower Kits MOM FRIENDLY. DAD READY. L24TWS Beverage Tower Kit Components L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower Introduction:

More information

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-6234 Telephone (800) 238-3600 Facsimile (612) 422-3246 Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER Part No. 185211000 January 25, 1984 Revised:

More information

COUNTER ELECTRIC & NON- CARBONATED POST-MIX DISPENSERS

COUNTER ELECTRIC & NON- CARBONATED POST-MIX DISPENSERS COUNTER ELECTRIC & NON- CARBONATED POST-MIX DISPENSERS CED-30 (6 valve) and CED-40 (8 valve) INSTALLATION & SERVICE GUIDE Part Number Manitowoc Beverage Equipment 2100 Future Drive w Sellersburg, IN 47172-1868

More information

INSTALLATION & SERVICE MANUAL QUANTUM SERIES

INSTALLATION & SERVICE MANUAL QUANTUM SERIES INSTALLATION & SERVICE MANUAL QUANTUM SERIES IMI CORNELIUS INC. One Cornelius Place Anoka, MN 55303 Tel: 1-888-248-5568 / 630-539-5050 Fax: 1-800-344-3801 / 630-539-6960 Part Number- 7208011206 Revision-

More information

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Date 10/08 Introduction IOD150,IOD200,IOD250

More information

PrimePour TM Operation Manual

PrimePour TM Operation Manual COT2000 SERIES PrimePour TM Operation Manual READ BEFORE USE. 840247001 7/14 For more Good Thinking visit www.commercial.hamiltonbeach.com 840247001_v18.indd 1 IMPORTANT SAFETY INSTRUCTIONS WARNING When

More information

Technician s Handbook. Flomatic Beverage Valves. Part Number STH15 9/10

Technician s Handbook. Flomatic Beverage Valves. Part Number STH15 9/10 Flomatic Beverage Valves Technician s Handbook This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.com America s Quality Choice

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

Bottled Water Dispenser

Bottled Water Dispenser Model # 900138: Page 1 USER MANUAL Bottled Water Dispenser Model # 7LCHSSF,7LCH WARNING TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING

More information

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E VANTAGE Installation Manual Release Date: April 16, 2003 Publication Number: 3120031005INS Revision Date: January 22, 2015 Revision: E Visit the Cornelius web site at www.cornelius.com for all your Literature

More information

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL Ice-O-Matic 111000 East 45th Ave Denver, Colorado 80239 Part Number 9081305-01 Rev. C Revision Date: September 19, 2011

More information

CF-1522 Beverage Dispensers

CF-1522 Beverage Dispensers CF-1522 Beverage Dispensers Installation, Use & Care Manual This manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.com Leader in Ice

More information

WATER DISPENSER INSTALLATION GUIDE

WATER DISPENSER INSTALLATION GUIDE WATER INSTALLATION GUIDE Before you begin: Your dispenser has two lines attached to it. The HOUSE WATER LINE attaches to your house s water supply. The REFRIGERATOR WATER LINE attaches to your refrigerator

More information

Operator Manual Autofill System

Operator Manual Autofill System Operator Manual Autofill System Bubbler Ratio 4:1 Ratio 5:1 Single 2001-001 2001-000 Double 2001-003 2001-002 Remote Single 2001-005 Remote Double 2001-004 Granita* Ratio 4:1 Ratio 5:1 Single 2002-001

More information

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table

More information

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section. DISPENSE TROUBLESHOOTING INDEX 1. No Flow of Water 2. Hot Water Flow but Cold Water is Not Flowing 3. Cold Water Flow but No Hot Water is Flowing 4. Low Flow of Water 5. Appears as white chunks in cup

More information

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ CS6-50-VD Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up of COOL-SPACE

More information

BEFORE OPERATING THE MACHINE: WARNING

BEFORE OPERATING THE MACHINE: WARNING BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this

More information

INSTALLATION AND SERVICE MANUAL FOR DELTA II REMOTE RECIRCULATING UNIT LANCER SERIES 9100

INSTALLATION AND SERVICE MANUAL FOR DELTA II REMOTE RECIRCULATING UNIT LANCER SERIES 9100 Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information

Installation Instructions CONVERTIBLE. Post-Mix Dispenser IMI CORNELIUS INC; Manual Part No January 1991 Revised October 6, 1992

Installation Instructions CONVERTIBLE. Post-Mix Dispenser IMI CORNELIUS INC; Manual Part No January 1991 Revised October 6, 1992 IMI CORNELIUS INC. One Cornelius Place Anoka, MN. 55303 6234 Telephone (800) 238 3600 Facsimile (612) 422 3232 Installation Instructions CONVERTIBLE Post-Mix Dispenser INSTALLATION AND SERVICE MANUAL WITH

More information

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250 INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250 Release Date: March 24, 2004 Publication Number: 92181INS Revision Date: April 07, 2014 Revision: G Visit the Cornelius web site at www.cornelius.com

More information

Installation Instructions for Cold Carbonation Retrofit (CCR) Kits

Installation Instructions for Cold Carbonation Retrofit (CCR) Kits Installation Instructions for Cold Carbonation Retrofit (CCR) Kits Read all of the instructions carefully before beginning installation. 1) Disconnect power to the dispenser, icemaker and carbonator. If

More information

Installation Manual CARBONATOR With Plain-Water Booster

Installation Manual CARBONATOR With Plain-Water Booster CORNELIUS INC One Cornelius Place Anoka, MN 55303-6234 Telephone (800) 238-3600 Facsimile (763) 422-3246 Installation Manual CARBONATOR With Plain-Water Booster IMPORTANT: It is the responsibility of the

More information

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products SERVICE MANUAL for by Vertex Model PWC-1800 P/N man-7011 Table of Contents 1. Introduction 2. Cooler Set-up 3. Remove Top Cover 4. Remove/Replace Float 5. Remove/Replace Hot Tank 6. Dispensing Solenoid

More information

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO--175 8 VALVE Release Date: March 24, 2004 Publication Number: 620917902INS Revision Date: April 08, 2014 Revision: E Visit the Cornelius web site

More information

PRE-INSTALLATION PROCEDURE

PRE-INSTALLATION PROCEDURE PRE-INSTALLATION PROCEDURE Required with each BLUPURA Water Treatment System. 1 each External Filter 1 each Chiller 1 each CO 2 Regulator 1 each External Filter 1 each Water Pressure Regulator 1 each 4

More information

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA Line to Refrigerator Ice/Water Dispenser Pump Module Dispenser www.xylemflowcontrol.com Flojet is a trademark of Xylem Inc. or one of its subsidiaries.

More information

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ] Product Manual Viscount IV series of carbonators and chillers Part Number 3B3075 Issue 01 [16-04-07] Contents Section Page Section Page Introduction 2 Safety 2 Description 2 Schematics 4 Fault Finding

More information

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com

More information

1 P a g e. G4 Counter Top OPERATION MANUAL

1 P a g e. G4 Counter Top OPERATION MANUAL 1 P a g e G4 Counter Top OPERATION MANUAL Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9

More information

Product Manual. Scotsman. Models: 10150, and 10250

Product Manual. Scotsman. Models: 10150, and 10250 Product Manual Scotsman Models: 10150, 10200 and 10250 IN TRO DUC TION This service manual is intended as a reference for the installer, user, and service agent of this Scotsman ice dispenser. It includes

More information

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions INSTALLATION MANUAL Series 322 Ice Cube Machine SPECIFICATIONS 7.00 15.00 C A 6 ft electrical cord 1.00 2.00 22.00 5.00 Front 16.38 11.25 5.00 F E Air In D 2.75 2.25 14.75.75 B 23.50 21.00 Opening 23.50

More information

INSTALLATION AND SERVICE MANUAL FOR THE SLIMLINE II, JUICE DISPENSER

INSTALLATION AND SERVICE MANUAL FOR THE SLIMLINE II, JUICE DISPENSER Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information

PRE INSTALLATION PROCEDURES

PRE INSTALLATION PROCEDURES PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this unit, failure to do so could

More information

REVERSE OSMOSIS SYSTEMS

REVERSE OSMOSIS SYSTEMS REVERSE OSMOSIS SYSTEMS TABLE OF CONTENTS R.O. SYSTEM DESCRIPTION... 2 R.O. EQUIPMENT INSTALLATION...3 R.O. SYSTEM CHECK-OUT PROCEDURE... 4 R.O. UNIT TURN ON PROCEDURE...5 R.O. UNIT RATING.. 6 R.O. BAY

More information

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY: PREC SION Water Systems OWNERS' GUIDE FOR MODELS: PWS 45-75 MANUFACTURED BY: PRECISION WATER SYSTEMS WATER DISTILLER PRECISION DESIGN & MANUFACTURING INC. 9024 100 STREET WESTLOCK, ALBERTA, CANADA, T7P

More information

BMW E36 Thermostat Removal And Coolant Flush

BMW E36 Thermostat Removal And Coolant Flush BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could

More information

This guide is intended to assist Heartland Owners in understanding how to winterize their water systems. Important Notices

This guide is intended to assist Heartland Owners in understanding how to winterize their water systems. Important Notices Winterization Guide This guide is intended to assist Heartland Owners in understanding how to winterize their water systems. Who created this document? Important Notices This document has been created

More information

Table of Contents. List of Figures

Table of Contents. List of Figures 1 P a g e Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9 Feed Water Connection....10

More information

SuperKlean Washdown Products

SuperKlean Washdown Products February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT

More information

PWC-500/1000/1010/1500

PWC-500/1000/1010/1500 SERVICE MANUAL for by Vertex Model PWC-500/1000/1010/1500 P/N man-7008 Table of Contents 1. Introduction 2. Cooler Set-up 3. Remove Top Cover 4. Remove/Replace Float 5. Remove/Replace Hot Tank 6. Faucet

More information

TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL

TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL Water Systems, LLC www.123filter.com Email: sales@123filter.com TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL Model #RCB4T ABOUT THE SYSTEM Reverse Osmosis process is a separation process. Tap water enters

More information

INSTALLATION INSTRUCTION Ver

INSTALLATION INSTRUCTION Ver ispring Reverse Osmosis Water Filter Systems INSTALLATION INSTRUCTION Ver 2005-6 Copyright 2005-2015 ISPRING WATER SYSTEMS, LLC. All rights reserved. Please keep this owner s manual for future reference.

More information

Manual update 2016 MC37/MFC3600

Manual update 2016 MC37/MFC3600 Manual update 2016 MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

Installation and Operation Manual

Installation and Operation Manual How To Install, Operate and Maintain Your Reverse Osmosis System FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT TO CHANGE. 475 PRO SERIES 475BP PRO SERIES INSTALLERS: PLEASE READ ALL INSTRUCTIONS BEFORE

More information

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products SERVICE MANUAL for by Vertex Model 7000 Table of Contents 1. Introduction 2. Cooler Set-up 3. Top Cover Removal 4. Remove/Replace Mechanical Float Valve Assembly 5. Removing/Replacing Control Panel and

More information

Manual for MC37/MFC3600

Manual for MC37/MFC3600 Manual for MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel

More information

Nichole Ernst CEO Powerhouse International

Nichole Ernst CEO Powerhouse International Dear Valued Customer, Thank you so much for your order. We are a family-owned business in Lincoln, NE and customer service is our priority. If you have any questions about your product, please feel free

More information

Tap Master Artesian Hydro Gardener Series Installation & Service Manual

Tap Master Artesian Hydro Gardener Series Installation & Service Manual Perfect Water Technologies 7 Tips for an Easy and Successful Installation 1. Keep it simple - there are 3 connections to make, and the tubing is color coded. 2. Have plenty of time, light, space, and towels

More information

Fountain Classic. Installation and Owner s Manual. Page 16

Fountain Classic. Installation and Owner s Manual. Page 16 Fountain Classic Installation and Owner s Manual Page 16 4120 NW 44th St Lincoln, NE 68524 USA Tel: 402.467.9300 Toll Free in the USA: 800.875.5915 Fax: 402.467.9393 www.purewaterinc.com Page 2 Fountain

More information

KITCHEN FAUCET COS-KF222C

KITCHEN FAUCET COS-KF222C KITCHEN FAUCET COS-KF222C USER S MANUAL & INSTALLATION GUIDE Thank You Thank you for your purchase. We know that you have many brands and products to choose from and we are honored to know that you have

More information

AUTOMATIC ICE-CUBE MAKER

AUTOMATIC ICE-CUBE MAKER AUTOMATIC ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having chosen

More information

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for Crathco Whipped Hot Chocolate Dispenser Operation and Instruction Manual Table of Contents Introduction...1 Specifications...2 Installation and Start-Up Procedures...2 How to Dispense Hot Chocolate...3

More information

HX-30/40 and HX-30/40 S Glass and Dishwashers

HX-30/40 and HX-30/40 S Glass and Dishwashers HX-30/40 and HX-30/40 S Glass and Dishwashers INSTALLATION OPERATION VERSION 18/01/00 2 Installation and Operation Instructions for Model HX-30/40 and HX-30/40 S (with built-in softener) Content Page 1

More information

Installing the Turbo Floor Model System

Installing the Turbo Floor Model System Installing the Turbo Floor Model System Location 1. Locate as close as possible to water supply source. 2. Locate as close as possible to a three-prong grounding receptacle. 3. Locate the System on a smooth

More information

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6 INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4

More information

5000 Series Bottled Water System by.

5000 Series Bottled Water System by. www.xylemflowcontrol.com 2015 Xylem Inc. All rights reserved. Flojet is a trademark of Xylem Inc. or one of its subsidiaries. 81000453 Rev A. 04/2015 5000 Series Bottled Water System by HOW THE SYSTEM

More information

Manual for MC91 SETUP INSTRUCTIONS

Manual for MC91 SETUP INSTRUCTIONS Manual for MC91 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

GROWMAX WATER Perfect Water for Plants and Gardens

GROWMAX WATER Perfect Water for Plants and Gardens GROWMAX WATER Perfect Water for Plants and Gardens WATER SYSTEMS FOR HYDROPONICS AND GARDENING GROWMAX 3000 Ultra-Pure Reverse Osmosis Water System Up to 3000 L/D of Pure Water Don't forget to register

More information

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL 1 INTRODUCTION Congratulations on choosing Permatech to improve the quality of your water. You will immediately begin to notice the numerous benefits of having

More information

Operator Manual Powdered Beverage Dispensers PIC3, PIC33A, PIC5, PIC6

Operator Manual Powdered Beverage Dispensers PIC3, PIC33A, PIC5, PIC6 Operator Manual Powdered Beverage Dispensers PIC3, PIC33A, PIC5, PIC6 Model PIC3 Model PIC5 with Island Option Safety Information...2 Installation...3 Operation...4 Cleaning...5 Adjustments...8 Maintenance...9

More information

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSER ICE/BEVERAGE DISPENSER MODELS: DB150, DB150-B, DB150-BC DB150-Z Operator s Manual Publication Number: 91328 Release Date: May 01, 1997 Revision date: May 08, 2014 Revision: E THIS DOCUMENT CONTAINS IMPORTANT

More information

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation requirements. IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance with AS/NZS

More information

LANCER SERIES H, ICE BEVERAGE DISPENSER 44 INCH WIDE, 12 VALVE, 115V/60Hz

LANCER SERIES H, ICE BEVERAGE DISPENSER 44 INCH WIDE, 12 VALVE, 115V/60Hz Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES Read and follow all steps and guides carefully before installing and using your reverse osmosis system. Do not use

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC Thermostatic Mixing Valve 0XTMV070 Certified to comply with ASME A.8.M 0 American Standard M97 Specifications Installation Adjust Temperature Service Replacement Parts

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Siphonic Ultra-High Efficiency Two-Piece Toilets HOptimum Single Flush Models 88AA / 88CA / 88DA HOption Dual Flush Models 886 / 88 / 889 Thank you for selecting American Standard

More information

Table of Contents Thank you 2 Accessories 2 Installation 2 Tapping your first mini keg 3 Operation 9 Cleaning 9 Important safeguards 10 Limited

Table of Contents Thank you 2 Accessories 2 Installation 2 Tapping your first mini keg 3 Operation 9 Cleaning 9 Important safeguards 10 Limited Table of Contents Thank you 2 Accessories 2 Installation 2 Tapping your first mini keg 3 Operation 9 Cleaning 9 Important safeguards 10 Limited warranty 10 1 Thank you Thank you for purchasing this EdgeStar

More information

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S 4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL Model No.: MCKC490S To ensure proper use of this appliance and your safety, please read the following instructions completely before operating this appliance.

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:

More information

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide http://waterheatertimer.org/tent-city-usa-water-heater.html Eccotemp L5 and L10 Comprehensive Listed below are some common questions and troubleshooting guidelines for our various models. Always remember

More information

L A signature series TA T N E RE O, A L L A T S IN

L A signature series TA T N E RE O, A L L A T S IN signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam

More information

ICE MAKER Use & Care Guide. Table of Contents... 2

ICE MAKER Use & Care Guide. Table of Contents... 2 ICE MAKER Use & Care Guide Table of Contents... 2 2217247 ICE MAKER SAFETY...2 ICE MAKER INSTALLATION...3 Unpacking...3 Location Requirements...3 Electrical Requirements...3 Leveling...4 Water Supply Connection...4

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Contents 1.0 INTRODUCTION... 1 2.0 UNPACKING YOUR COOL-SPACE UNIT... 1 3.0 SET-UP

More information

ULTIMATE REVERSE OSMOSIS SYSTEM

ULTIMATE REVERSE OSMOSIS SYSTEM ULTIMATE REVERSE OSMOSIS SYSTEM INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 3.1 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful information

More information

WATT R TWIN Energy-Efficient Home Water System

WATT R TWIN Energy-Efficient Home Water System WATT R TWIN Energy-Efficient Home Water System Owner and Installation Manual 3725 Touzalin Avenue Lincoln, NE 68507 USA Tel: 402.467.9300 Toll Free in the USA: 800.875.5915 Fax: 402.467.9393 www.purewaterinc.com

More information

Water Boilers ME10EN, ME15EN. Table of Contents

Water Boilers ME10EN, ME15EN. Table of Contents Water Boilers ME10EN, ME15EN Operator Manual Model ME15EN Model ME10EN Safety Information...2 Rough-In Drawing...3 Installation...4 Priming...5 Cleaning...5 Table of Contents Adjustments...6 Maintenance...7

More information

Refrigerator. Installation Guide. Free Standing Appliance

Refrigerator. Installation Guide. Free Standing Appliance Refrigerator Guide Free Standing Appliance Untitled-3 1 2018-04-10 12:31:22 Follow these instructions carefully to prevent accidents and to ensure the proper installation of this refrigerator. WARNING

More information

Service manual NORDIC. Juice machine S / EN. Rev Din återförsäljare / Your retail dealer

Service manual NORDIC. Juice machine S / EN. Rev Din återförsäljare / Your retail dealer Service manual NORDIC Juice machine Din återförsäljare / Your retail dealer S / EN...... Rev. 090915 Dispenser Dispenser description for Nordic Nordic is a dispenser for cooling water and mixing juice-

More information

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models

More information

USER MANUAL WATER DISPENSER WITH ICE MAKER

USER MANUAL WATER DISPENSER WITH ICE MAKER USER MANUAL WATER DISPENSER WITH ICE MAKER Model:048-GM-48200 Please read this owner s manual carefully before operating the unit. TABLE OF CONTENTS INTRODUCTIONS... 3 IMPORTANT SAFETY INSTRUCTIONS.. 3

More information

Liberty-Classic. Operator s Manual

Liberty-Classic. Operator s Manual Liberty-Classic Operator s Manual Pure & Secure LLC 4120 NW 44th Lincoln, NE 68524 Phone: 402-467-9300 Fax: 402-467-9393 2006, Pure & Secure LLC. All Right Reserved Table of Contents Important Safety

More information

Nexus FS Filtration Installation Guide. September 19, 2011

Nexus FS Filtration Installation Guide. September 19, 2011 Nexus FS Filtration Installation Guide September 19, 2011 DSW-Filtration Install Guide:05201011:rev-12122011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical

More information

Installation Instructions EFS Hand Washing Station

Installation Instructions EFS Hand Washing Station Installation Instructions EFS Hand Washing Station Both water and soap are sequenced and dispensed from outlet. Override button allows for non potable, water-only dispensing. Lighted icons indicate the

More information

FLOW-THROUGH FURNACE HUMIDIFIER

FLOW-THROUGH FURNACE HUMIDIFIER FLOW-THROUGH FURNACE HUMIDIFIER Model 5000/6000 Warranty Maintenance Troubleshooting Guide 2 WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE WARRANTY The manufacturer guarantees the for the period of one year

More information

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up

More information

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased

More information