Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Size: px
Start display at page:

Download "Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series"

Transcription

1 Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers to condense. Lower return temperatures to the boiler. Operate the boiler at a lower temperature.

2 Standard Equipment Brazed Plate Heater-BPH Series Plate and Frame Heater-PFH Series Cemline Brazed Plate Heaters are completely packaged and ready to use. All components are sized, mounted and piped prior to shipment. These heaters come complete and require only connection to services Advantages of Cemline Packaged Plate Boiler Water Fired Water Heater Cemline Packaged Plate Boiler Water Fired Water Heaters (BPH/PFH) are a perfect choice for domestic water heating systems using hydronic boilers including cast iron, copper tube, water tube, or specialty high efficiency boilers. The BPH uses a brazed plate heat exchanger for smaller loads while the PFH uses a plate and frame heat exchanger for larger loads. The BPH/PFH heat exchanger allows these boilers to operate more efficiently since the BPH/PFH heat exchangers can return the boiler water to the hydronic boiler at lower temperatures than the traditional u-bend heat exchanger. The boiler water can be returned to the boiler as low as 90 F from the BPH/PFH water heaters. Cemline Plate Heaters (BPH/PFH) are completely packaged and ready for use. The BPH/PFH can be used in conjunction with an existing tank or used as an instantaneous water heater. The heaters come complete and require only connection to services. The BPH/PFH heat exchanger has a high heat transfer rate allowing for maximum heat transfer between the boiler water and the domestic water. As the heat is transferred from the boiler water to the domestic water, the boiler water can experience large temperature drops through the heat exchanger. The BPH/PFH can achieve larger temperature drops through the heat exchanger requiring less gallons per minute of boiler water than a traditional U-bend heat exchanger that is performing a 20 F delta T on the boiler water side. The large temperature drops occur without laminar flow on the boiler water side of the heat exchanger. The heat exchanger can even allow for temperature crosses between the boiler water outlet and the domestic water outlet temperature, meaning the domestic water outlet temperature can be greater than the returned boiler water temperature. The boiler can be run at lower temperatures with the BPH/PFH s ability to perform temperature crosses and to take large delta T s as a lower boiler water temperature can be used to make domestic hot water. Cemline Corporation Plate Water Heaters are available with a storage tank either a cement lined STONESTEEL or 316-L stainless steel vessel in sizes 60, 120, 200, 300, 500, and 680 gallon capacity. See Cemline SPH brochure for more details. The Cemline BPH/PFH comes factory standard with a 2-way electronically operated control valve. The 2-way electronically operated control valve allows for close temperature control of the water heater by modulating flow of the boiler water through the heat exchanger. The BPH/PFH can achieve +/-2 F with a steady state flow and +/- 4 F under normal operating conditions. The 1000:1 turn down ratio of the control valve allows for accurate control of these water heaters. The Cemline BPH/PFH can be used for a variety of heat recovery systems or in hot water or chilled water systems. Contact Cemline Corporation with your specific application. Basic BPH/PFH Package Includes: 16 gauge steel frame with hammertone enamel paint Steel channel base Electronic temperature gauge. Water pressure gauge Brazed Plate Heat Exchanger (BPH) Plate & Frame Heat Exchanger (PFH) Integral bronze circulator Clean out ports Single safety system with electronic limit control 2-Way Electronic Boiler Water Control Valve CEM-TROL Control Module Boiler water temperature gauge Inlet boiler water strainer Inlet domestic water strainer Pressure temperature relief valve Optional Trim Double Walled Plate Heat Exchanger (Brazed Plate or Plate and Frame) Boiler water pump Aquastat for boiler water pump Balance valve 3-way electronic boiler water control valve Multiple Brazed Plate units can be piped together with by-passes for larger flow rates or for redundancy Blowdown valves on strainers PT plugs California AB-1953 Lead-Free components 2

3 Standard Equipment Cemline Brazed Plate Heaters and Plate and Frame Heaters Cemline Brazed Plate Heaters and Plate and Frame Heaters are completely packaged and ready to use. All components are sized, mounted and piped prior to shipment. These heaters come complete and require only connection to services CEM-TROL Control Module and Electronically Operated Control Valve Cemline CEM-TROL Solid State Water Heater Control Module incorporates operating and limit functions in one solid state controller. The controller features a LCD display of the temperature and on board operating PID temperature control along with high temperature safety cut offs and alarm indications. The CEM-TROL simplifies the control of Cemline Water Heaters, enhances the look of the product, and follows the industry trend to solid state controls. Electronically operated control valve used for boiler water applications. Electronically operated control valves use a solid state temperature sensor which is wired to the CEM-TROL control module. The CEM-TROL has an adjustable set point. The control module compares the set point with the sensed temperature and sends an electric signal to a magnetic linear actuator on the control valve. The magnetic linear actuator modulates the control valve and regulates the amount of boiler water through the valve to maintain the set point of the controller. When the set point is achieved the CEM-TROL sends a signal to the valve actuator and the valve closes. In the event of high temperature or loss of building power the CEM-TROL shuts off the electric power to the control valve closing the valve. CEM-TROL Features Built in PID Control Signal (PID Control Signal to control electronic valve or control I-P transducer on Air operated control valve) Built in On-Off Switch Built in Single Point Wiring Built in High Temperature Set Point (Closes control valve in event of a high temperature situation) Built in Secondary High Temperature Set Point (Opens a water solenoid to dump over heated water down the drain) Built in Remote Temperature Setting (Building Automation System can remotely set the operating temperature using a 4-20 ma signal) Built in LCD Display of Functions Power On Primary High Temperature Indication Secondary High Temperature Indication Built in contacts to notify BAS (Building Automation System) of functions Power On Primary High Temperature Secondary High Temperature Operating Temperature (4-20 ma) Any Limit CEM-TROL Ratings Input Selectable 120/220 VAC-50/60 HZ Output Contacts: 1 amp at 24 VAC Building Automation outputs: Dry contacts, NO/NC 0.5 amp maximum, non inductive Display: LED display with resolution of 0.3% of scale Available temperature ranges: 32 F 200 F Operating ambient temperature: Min 32 F Max 1 F Operating Humidity: 5% to 95% relative humidity (RH) non-condensing NEMA 4 enclosure UL listed Digital Electronic Temperature Limit Control. BPH/PFH Water Heaters have a Digital Electronic Limit Control with LCD readout. The ASME code requires that water heaters utilizing boiler water as the energy source have a high limit temperature control. The CEM-TROL has an easily field-programmable high limit set point and differential. 3

4 Recovery Capacities Cemline Brazed Plate and Plate Frame Heaters Heat exchanger sizing for BPH/PFH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline website at Please contact Cemline or your local representative for sizing or for access to the on-line sizing program. Domestic Water Recovery Boiler Water as Energy Source Hex Model # Flow Rate gpm (ϒF) (ϒF) (ϒF) (ϒF) gpm * 2000* 2250* * * * * Domestic Water Recovery Hex Model # * 1750* 2000* 2250* Flow Rate gpm * * 60 00* * 100 Boiler Water as Energy Source (ϒF) (ϒF) (ϒF) (ϒF) gpm BPH water heaters are not recommended for water with hardness over 1 parts per million. If water hardness exceeds 1 ppm either put a water softener in the system or use Cemline SEH, SSH, or SWH series water heaters. * When using a double wall heat exchanger a plate and frame style is required for these conditions. Domestic Water Recovery Boiler Water as Energy Source Hex Model # Flow Rate gpm (ϒF) (ϒF) (ϒF) (ϒF) gpm * 1750* 2000* 2250* * * * *

5 Cemline Plate Heaters Dimensional Data - Brazed Plate Heat exchanger sizing for BPH/PFH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline website at Please contact Cemline or your local representative for sizing or for access to the on-line sizing program. L W Temperature Sensors (or installed in storage tank) Relief Valve Pipe to Drain Control Valve Boiler Water Inlet Hot Water Outlet 36 H Boiler Water Outlet Cold Water Inlet Boiler Water Temperature Gauge Model Number W L H BPH BPH 2000 and Above 16" 24" 36" 36" 51" 51" 5

6 Recovery Capacities Dimensional Data - Plate and Frame Heaters Heat exchanger sizing for BPH/PFH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline website at Please contact Cemline or your local representative for sizing or for access to the on-line sizing program. Thermometer L Control Valve W Relief Valve Temperature Sensors CEM-TROL Boiler Water Inlet Strainer Boiler Water Outlet Hot Water Outlet Pressure Gauge Cold Water Inlet H 4 Steel Channel Base Domestic Water Strainer Model Number W L H PFH PFH 3000 and Above 24" 30" 48" 54" 45" 52" 6

7 BPH and PFH Water Heaters- Sample Specifications For specifying Cemline Packaged Brazed Plate Boiler Water Fired Water Heater water heaters, select model from charts and use specification below. Cemline has representation in most major cities, or consult factory. BPH Water Heaters Plate heater shall be Cemline Series BPH (or PFH); factory assembled and packaged. Heater shall be mounted on an enameled metal base, 16 gauge minimum thickness. Heater shall be factory assembled and piped including electronic operated 2-way temperature regulating valve. Heat exchanger shall be single walled brazed copper brazed 316L stainless steel plate type (or double walled copper brazed 316L stainless steel plate type) and shall have an integral valved circulator to re-circulate the water through the heat exchanger. Heater shall be supplied with solid-state control module with LED backlit LCD display and LED pilot lights to indicate on-off, primary high limit, and secondary high limit. Solid-state control module shall be provided with a field programmable digital electronic PID controller allowing the owner to set operating and temperature limits on the display screen. Solid-state control module shall have red alarm light and alarm horn with built in alarm silence relay. Solid-state control module shall be supplied with dry contact closure outputs to indicate to building automation system (BAS) the occurrence of power on, primary high temperature, and secondary high temperature. The control module shall allow the BAS to turn the heater on or off through a remote relay suitable for 24 VAC, 1 amp. The control module shall allow the BAS to remotely set the temperature of the heater using a 4-20 ma input signal. The control module shall allow the BAS to remotely monitor the operating temperature. Control module shall be supplied with an on-off switch and shall be mounted in a NEMA 4 panel. All solenoids and limits shall be 24 VAC. Heater shall be furnished with a water pressure gauge and an A.S.M.E. pressure-temperature relief valve of sufficient size to relieve total BTU input of heat exchanger. Manufacturer shall assume responsibility for correct sizing of components to assure performance designated in design criteria. Heater shall be CEMLINE Corporation Model BPH/PFH. Unit dimensions width x long x height. Plate exchanger to heat GPH from F to F with GPM of F inlet F outlet Hot Water. Cemline BPH/PFH Series Packaged Heaters are normally piped as shown below. To System Boiler Water In Hot Water Boiler BPH/ PFH Hot Water Out Storage Tank House Recirculation Cold Water Supply Boiler Water Out 7

8 Sales Offices Other Sales Offices: Alaska Hawaii Puerto Rico Taiwan Graphical Interfaces Informational Sections Agent Locator Plant Tour Sizing programs for all products Catalog Brochures Available STONESTEEL Water Storage Tanks STONESTEEL Jacketed Storage Tanks Submerged Heating Coils Replacement Tube Bundles Steel Tanks Chilled Water Buffer Tanks System Efficiency Buffer Tanks STONESTEEL Commercial Electric Water Heaters Electric Boilers STONESTEEL Packaged Copper Coil Water Heaters Stainless Compact Packaged Copper Coil Water Heaters - Semi-instantaneous, Instantaneous Unfired Steam Generators Condensed Catalog Cemline is represented in all major cities. Please contact your local representative or call Cemline Corporation Cemline Corporation All Rights Reserved. All trademarks on this brochure are the property of Cemline Corporation, unless otherwise noted or in any other way set forth as a third party rights. Unauthorized use of these trademarks, as well as the materials presented on this site, is expressly prohibited and constitutes a violation of the intellectual property rights of Cemline Corporation. Vol. 4 Scan to view our mobile web link. CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

9 SPH Series Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA PHONE: (724) FAX: (724)

10 Advantages of Cemline Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters Cemline Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heater (SPH) is a perfect solution for domestic water heating systems using hydronic boilers including cast iron, copper tube, water tube, or specialty high efficiency condensing boilers. The SPH heat exchanger allows high efficiency condensing boilers to operate more efficiently since the SPH heat exchanger can return the boiler water to the hydronic boiler at lower temperatures than the traditional u-bend heat exchanger. The boiler water can be returned to the boiler as low as 90 F from the SPH water heater. The SPH heat exchanger has a high heat transfer rate allowing for maximum heat transfer between the boiler water and the domestic water. As the heat is transferred from the boiler water to the domestic water, the boiler water can experience large temperature drops through the heat exchanger using less boiler water without experiencing laminar flow on the boiler water side of the heat exchanger. The heat exchanger can even allow for temperature crosses between the boiler water outlet and the domestic water outlet temperature, meaning the domestic water outlet temperature can be greater than the returned boiler water temperature. This heater can be used in many hydronic heating style applications including those systems using low temperature boiler water. The SPH heater can also be used in in condensate systems by recovering heat from the condensate to produce hot water. Cemline Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters (SPH) are completely packaged and ready for use. The tank allows for storage of hot water and all components are sized, mounted and piped prior to shipment. The heaters come complete and require only connection to services. Cemline Corporation SPH Series Water Heaters are available with Cement Lined STONESTEEL or 316-L stainless steel vessel in sizes 60, 120, 200, 300, 500, and 680 gallon capacity. The time tested STONESTEEL lining is a unique formulation of hydraulic cement that is durable, reliable, troublefree lining know for hot water storage. Optionally, the 316-L stainless steel is corrosion resistant and with solid 316-L stainless steel vessel no lining is required. The Cemline SPH comes factory standard with a 3-way electronically operated boiler water control valve. The 3-way electronically operated control valve allows for close temperature control of the water heater by modulating flow of the boiler water through the heat exchanger. The 1000:1 turn down ratio of the control valve allows for accurate control of these water heaters. Standard SPH Package Features A.S.M.E. CODE constructed National Board Registered Storage tank (125 PSIG WP)... ASME Code stamping and registration offers the assurance of quality controlled construction. STONESTEEL lining...stonesteel prevents rust or and corrosion. OR 316-L Stainless Steel Vessel...Type 316-L Stainless is virtually rustproof. Brazed Plate or...extremely efficient. Allows close temperature approaches. Plate & Frame Heat Exchanger 3 Fiberglass insulation... Prevents heat loss to cut operation costs. Meets latest ASHRAE standards. 20 gauge steel jacket with hammertone enamel paint... Protect insulation & provides neat finished appearance with hammertone enamel painted exterior. Standard operating controls... All components necessary for safe-complete-operation. All gauges, relief valves, controls, and piping factory piped and mounted. Over-temperature safety system which will close the main control valve upon an over-temperature condition. This system utilities an adjustable electric thermostat which monitors the temperature of the water and if over-temperature condition is detected, sends an electric signal to the valve, thereby closing the valve. This system requires a 120 volt 5 amp circuit. Optional Safety System... Double safety system: This is an optional over-temperature safety system which will deactivate the main control valve, as described above and also open a solenoid valve at the top of the vessel to drain. This system requires a 120 volt 5 amp circuit. 2

11 Standard Equipment Cemline Storage Plate Heat Exchanger Water Heaters Cemline Storage Plate Heaters are completely packaged and ready to use. All components are sized, mounted and piped prior to shipment. These heaters come complete and require only connection to services. Basic SPH Package Includes: A.S.M.E. CODE Constructed National Board Registered storage tank STONESTEEL lining 316-L Stainless Steel threaded connections 3 Fiberglass insulation Optional 316-L Stainless Steel Vessel* (Note: 60 gallon only available in 316-L stainless steel) Double Walled Plate and Frame Heat Exchanger Boiler water pump Aquastat for boiler water pump 20 gauge steel jacket with hammertone enamel paint Structural steel base A.S.M.E. relief valve-pressure and temperature Electronic temperature gauge Water pressure gauge Drain valve Brazed Plate Heat Exchanger Integral bronze circulator Single safety system with electronic limit control 2 or 3-Way Electronic Boiler Water Control Valve Boiler water temperature gauge CEM-TROL control module 3

12 Digital Electronic Temperature Control Cemline Storage Plate Heat Exchanger Water Heaters SPH water heaters have a CEM-TROL electronic control and limit with LCD readout. Electronically Operated Control Valves Electronically operated control valve used for boiler water applications. Electronically operated control valves use a solid state temperature sensor which is wired to the CEM-TROL electronic control module. The control module has an adjustable set point. The CEM-TROL compares the set point with the sensed temperature and sends an electric signal to a magnetic linear actuator on the control valve. The magnetic linear actuator modulates the control valve and regulates the amount of boiler water through the valve to maintain the set point of the controller. As the set point is approached the controller sends a signal to the valve actuator and modulates the valve to a closed position. In the event of high temperature or loss of building power the limit control interrupts the power to the controller which closes the valve. Digital Electronic Temperature Limit Control SPH Water Heaters have a CEM-TROL Digital Electronic Limit Control with LCD readout. The ASME code requires that water heaters utilizing boiler water as energy source have a high limit temperature control. Our limit controller is a solid state device with LCD readout of temperature, set point and differential and easily field-programmable. Standard: Single Safety System: This temperature controller is a single set point limit control will act directly to close an electronic control valve on over temperature. Optional: Double Safety System: This temperature controller is a dual set point limit control. The first set point output will act directly to close an electronic control valve on over temperature. The second adjustable set point output will open a water solenoid to drain excessively heated water from the water heater. Since there are two set points and two outputs, the water drain solenoid set point can be set at a slightly higher temperature than the valve close-off temperature. Advantages over electro-mechanical device: Solid state device/no mechanical parts to wear out. Digital readout on large LCD screen. Easily adjustable set point and differential. Dual set points for double safety system. Accuracy within +1 F. As a safety measure, all heaters are designed to shut off on loss of primary power. Specifications: Set point adjustment range: F Input: 115v AC Temperature Sensor: 1000 ohm Operating Ambient: 32 to 1 F Operating Humidity: 5% to 95% RH (Noncondensing) 4

13 Recovery Capacities - Single or Double Wall Brazed Plate Heater and Double Wall Plate & Frame Heater The listing below is for the boiler water temperatures and temperature rises which are most widely used. Heat exchangers are available for other boiler water temperatures and different temperature rises. Consult factory for further information. Domestic Water Recovery Hex Model # * 1250* 1300* 1750* 2000* 2250* Flow Rate gph * 3000 Boiler Water as Energy Source ( F) ( F) ( F) ( F) gpm Domestic Water Recovery Hex Model # * 1250* 1300* 1750* 2000* 2250* Flow Rate gph * 3000 Boiler Water as Energy Source ( F) ( F) ( F) ( F) gpm Domestic Water Recovery Hex Model # * 1250* 1300* 1750* 2000* 2250* Flow Rate gph * 3000 Boiler Water as Energy Source ( F) ( F) ( F) ( F) gpm When using a double wall heat exchanger a plate and frame style is required for these conditions. SPH water heaters are not recommended for water with hardness over 1 parts per million. If water hardness exceeds 1 ppm either put a water softener in the system or use Cemline SWH series water heaters. 5

14 CEM-TROL SPH Water Heaters - Dimensional Data Cemline SPH Series (single wall or double wall brazed plate) vertical Packaged Heaters are normally piped as shown below. Also available with 2-way control valve. Brazed Plate Unit CEM-TROL GALLON CAPACITY MODEL NUMBER TANK SIZE D x L W H O J M S A & B* 60 V60SPH 24" x 36" 28" 56" 78" 27" 16" 20" 1 1/2" 120 V120SPH 24" x 63" 28" 77" 78" 24" 10" 20" 1 1/2" 200 V200SPH 30" x 76" 34" 90" 82" 28" 10" 24" 1 1/2" 300 V300SPH 36" x 80" " 94" 85" 28" 10" 25" 1 1/2" 500 V500SPH 42" x 90" 46" 104" 90" 30" 10" 32" 1 1/2" 680 V680SPH 48" X 96" 52" 110" 91" 30" 12" 42" 2" *Inlet and outlet dimensions listed are standard size. Please verify maximum flow rate. X 42" 42" 45" 51" 63" 69" Y 79" 79" 82" 85" 91" 106" 6

15 CEM-TROL SPH Water Heaters - Dimensional Data Cemline SPH Series (single or double wall plate and frame) vertical Packaged Heaters are normally piped as shown below. Also available with 2-way control valve. Plate and Frame Unit Y Cold Water Inlet Pressure Gauge CEM-TROL Boiler Water Temperature Gauge Strainer GALLON CAPACITY MODEL NUMBER TANK SIZE D x L W H O J M S A & B* 60 V60SPH 24" x 36" 28" 56" 78" 27" 16" 20" 1 1/2" 120 V120SPH 24" x 63" 28" 77" 78" 24" 10" 20" 1 1/2" 200 V200SPH 30" x 76" 34" 90" 82" 28" 10" 24" 1 1/2" 300 V300SPH 36" x 80" " 94" 85" 28" 10" 25" 1 1/2" 500 V500SPH 42" x 90" 46" 104" 90" 30" 10" 32" 1 1/2" 680 V680SPH 48" X 96" 52" 110" 91" 30" 12" 42" 2" *Inlet and outlet dimensions listed are standard size. Please verify maximum flow rate. 7 X 42" 42" 45" 51" 63" 69" Y 79" 79" 82" 85" 91" 106"

16 Sample Specifications Heat exchanger sizing for SPH can be obtained by using Cemline Corporation s automatic sizing program on the Cemline CD Rom or from the internet at Please contact Cemline or your local representative for sizing or for a copy of the sizing program. SPH Water Heaters Storage heater shall be Cemline Series SPH; factory assembled and packaged. Water heater shall be constructed in accordance with ASME Code for a working pressure of 125 psig. The packaged water heater shall be constructed with a vertical steel tank, cement lined (or 316-L stainless steel) with 316-L stainless threaded openings. Heater shall be mounted on a steel support skid and shall have concealed lifting lugs. Heater shall be insulated with 3 Fiberglass protected by an enameled metal jacket, 20 gauge minimum thickness. Heater shall be factory assembled and piped including electronic operated 2 or 3-way temperature regulating valve. Heat exchanger shall be single wall copper brazed 316L Stainless Steel Plate Type (or double wall brazed or double wall plate and frame heat exchanger) an integrated cover and shall have an integral valved circulator to circulate domestic water through the heat exchanger into the bottom of the tank. Heater shall be provided with a field programmable digital electronic limit control with LCD readout and digital thermometer. Heater shall be furnished with a water pressure gauge and an A.S.M.E. pressure-temperature relief valve of sufficient size to relieve total BTU input of the coil. Manufacturer shall assume responsibility for correct sizing of components to assure performance designated in design criteria. Heater shall be Cemline Corporation Model V SPH. Tank dimensions diameter x long. Storage gallon capacity. Plate exchanger to heat GPH from F to F with GPM of F inlet - F outlet Hot Water Cemline Corporation All Rights Reserved. All trademarks on this brochure are the property of Cemline Corporation, unless otherwise noted or in any other way set forth as a third party rights. Unauthorized use of these trademarks, as well as the materials presented on this site, is expressly prohibited and constitutes a violation of the intellectual property rights of Cemline Corporation. Vol. 3 Scan to view our mobile web link. CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA PHONE: (724) FAX: (724)

17 CCH Series Condensing Companion Heater The Cemline Condensing Companion Heater (CCH) is a perfect solution for producing domestic hot water when using a Hydronic Condensing Boiler. The package consists of storage vessel, brazed plate heat exchanger, and domestic water pump. The boiler s controller monitors the domestic hot water temperature in the tank turning on and off a boiler water pump to maintain the desired domestic water temperature. Optionally, a boiler water pump and pump control panel can be supplied by Cemline. The Condensing Companion Heater (CCH) is completely packaged and ready to install. CCH Series Features ASME Pressure Vessel ASME Code Stamping and Registration offer the assurance of quality controlled construction. STONESTEEL Tank Prevents rust and corrosion. Brazed Plate Heat Exchanger Highly efficient allowing for optimal heat transfer between the boiler water and the domestic hot water. Intratank Circulating Pump Constant flow through heat exchanger maintaining a constant domestic water temperature while reducing the risk of legionnaire s disease. Well for Boiler Controller Condensing boiler monitors Temperature Sensor domestic hot water temperature as required. Jacket and Insulation gauge steel jacket protects the insulation and provides a neat finished appearance with hammertone enamel painted exterior. Insulation prevents heat loss and meets ASHRAE standards. ASME Relief Valve Temperature and pressure relief valve sized to relieve in the event of over temperature or pressure situations Gauges Thermometer and Pressure Gauge indicating vessel temperature and pressure. Optional Equipment Stainless Steel Vessel Type 316-L provides long life with corrosion resistance. Boiler Water Pump Turns on from boiler s control to maintain desired set point in the tank. Unit shown with optional Boiler Water Pump. Control Panel Interfaces with condensing boiler s controller to turn boiler water pump on/off controlling temperature of the water heater. Includes On/Off switch, power on light, pump running lights..

18 CCH Series Sizing Chart Available with Single or Double Wall Brazed Plate Heat Exchangers. GPH Recovery at Degree Rise Gallon BTU/Hr 80 F 100 F Model Capacity Input to 120 to 1 V120CCH , V120CCH , V120CCH , V120CCH , V120CCH ,000, GPH Recovery at Degree Rise Gallon BTU/Hr 80 F 100 F Model Capacity Input to 120 to 1 V200CCH , V200CCH , V200CCH , V200CCH ,000, V200CCH ,200, GPH Recovery at Degree Rise Gallon BTU/Hr 80 F 100 F Model Capacity Input to 120 to 1 V300CCH , V300CCH ,000, V300CCH ,200, V300CCH ,500, V300CCH ,000, GPH Recovery at Degree Rise Gallon BTU/Hr 80 F 100 F Model Capacity Input to 120 to 1 V500CCH ,000, V500CCH ,200, V500CCH ,500, V500CCH ,000, V500CCH ,500, Energy Source: Boiler Water, typically 180,, 150, or 1 of with a 30 - F Delta T. (1 F boiler water can not be used to produce 1 F of domestic water.) Dimensional Data "C" Relief Valve Temperature Gauge Pressure Gauge Boiler Water Outlet 3/4" NPT for Remote Temperature Sensor Provided by Others 8" 8" 3" Fiberglass w/20ga. Steel Jacket "B" NPT Hot Water Outlet Boiler Water Intlet F Boiler Water Temperature Gauge "A" NPT Cold Water Inlet J X O Unit shown with optional Boiler Water Pump. 1" NPT Drain Three Jacket Stands MODEL NUMBER GALLON CAPACITY TANK SIZE D x L W H J X F O A B V120CCH " x 63" 28" 66" 14" 25" " 32" 2" 3/4" V200CCH " x 76" 34" 80" 16" 28" 46" 37" 2" 1" V300CCH " x 80" " 84" 17" 28" 52" " 2" 1" V500CCH* " x 90" 46" 94" 20" 31" 58" 48" 2" 1" * V500CCH models will be supplied with 12 x 16 manhole C 3/4" 1" 1" 1" 2012 Cemline Corporation All Rights Reserved. All trademarks on this brochure are the property of Cemline Corporation, unless otherwise noted or in any other way set forth as a third party rights. Unauthorized use of these trademarks, as well as the materials presented on this site, is expressly prohibited and constitutes a violation of the intellectual property rights of Cemline Corporation. Vol. 1 Scan to view our mobile web link. CEMLINE CORPORATION P.O. BOX 55 CHESWICK,. PENNSYLVANIA PHONE: (724) FAX (724)

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers

More information

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION SPH Series Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA

More information

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters SEH Series Stainless Steel Instantaneous Packaged Steam Fired Water Heaters utomated On-line Sizing Program CEMLINE CORPORTION P.O. BOX 55 CHESWICK, PENNSYLVNI 15024 Phone: (724) 274-5430 FX: (724) 274-5448

More information

Water Heaters. Solar Applications

Water Heaters. Solar Applications Water Heaters Applications (Optional) 3-way diverting valve Pump Bypass for Cooling Water Bypass Return STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK,

More information

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal SWH Series STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal NOW AVAILABLE Automated On-line Sizing Program STONESTEEL is a Registered Trademark

More information

Heat Transfer Packages

Heat Transfer Packages Heat Transfer Packages Heat Transfer Package (HTP Series) Building Heat, Process Heat, Swimming Pool Heater, Cooling Applications and Snow Melt Package (SMP Series) Steam,, High Temperature Hot Water,

More information

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters FFH Series Steam Fired Instantaneous Feed Forward Water Heaters CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448 www.cemline.com Operation of Cemline

More information

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION EHB Series STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55

More information

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source USG Series Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430

More information

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code Cemline Steel Tanks Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code CEMLINE CORPORATION P.O. BOX 55 CHESWICK, PENNSYLVANIA 15024 Phone: (724) 274-5430 FAX: (724) 274-5448

More information

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT CEMLINE Unfired Steam Generators are designed to produce clean steam with steam or high temperature hot water as an energy source for use where there is a need to produce clean steam from boiler steam

More information

Packaged Semi-Instantaneous Steam Fired Water Heater

Packaged Semi-Instantaneous Steam Fired Water Heater MODEL STX Packaged Semi-Instantaneous Steam Fired Water Heater Shell and Tube Style Heater Features Reliable Only high grade materials used in construction to ensure long operating life Heat exchange pressure

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

Semi-Instantaneous Indirect Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands

More information

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water Packaged Instantaneous Domestic Hot Water Generator Energy Source: Shown with optional boiler water valve and electronic feed-forward control. Operates with low boiler water supply and return temperatures

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Control and power circuit fusing to meet N.E.C.

Control and power circuit fusing to meet N.E.C. LARGE VOLUME ELECTRIC WATER HEATERS SEV & SEH MODELS Commercial Electric ADVANCED State s new propriety electronic water heater control, provides precise + or - 1ºF temperature control, that is ideal for

More information

Installation, Operation and Maintenance

Installation, Operation and Maintenance Bulletin No. 534 Installation, Operation and Maintenance Unfired Steam Generators (Series RB) Horizontal USG Vertical USG Disclaimers This Installation, Operation, and Maintenance Manual is intended to

More information

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance Unfired Steam Generators (Series RB) Installation, Operation and Maintenance Horizontal USG Vertical USG 534-EN Please read and save these instructions Disclaimers This Installation, Operation, and Maintenance

More information

EZ Plate Instantaneous

EZ Plate Instantaneous EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

Indirect Fired Water Heater

Indirect Fired Water Heater Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI. TURBOPOWER Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater E N GI N E E R E D D U P L E X A L L O Y 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty PVI.com Ultra Reliable,

More information

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free

More information

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION $7.50 Installation, Operation, and Maintenance Manual CEMLINE CORPORATION Unfired Steam Generators (USG Series) Horizontal USG Vertical USG CEMLINE CORPORATION P. O. Box 55, Cheswick, PA, 15024 Phone:

More information

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation AY-414 This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions Pre-assembled, freeze-protected safety fixture and SNA heater skid system Bradley Heat Trace S19-300 with SpinTec 54-144 kw (491,300 BTUs) Molded Duragrate and integrated shower pan Temperature overshoot

More information

SECTION WATER HEATERS

SECTION WATER HEATERS SECTION 15457 WATER HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete hot water generating system with necessary accessories as indicated on Construction Documents, as specified, and

More information

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Form No. 2300-7 (Rev. 2/99) Gas, il or Dual Fuel Fired Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Originators of the Flexible Water Tube

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 8413 - HUMIDIFIERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT SECTION 22 30 00 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Commercial High Efficiency Storage Type Gas Water Heaters 2. Packaged Domestic Plate and Frame Water Heating System 3. Commercial Instantaneous

More information

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20

More information

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

PROVIDES TEPID WATER FOR EMERGENCY SHOWER PROVIDES TEPID WATER FOR EMERGENCY SHOWER Model EMV FEATURES Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL SECTION 22 14 00 DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 00 10,

More information

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane

More information

High Efficiency Commercial Gas Water Heaters

High Efficiency Commercial Gas Water Heaters High Efficiency Commercial Gas Water Heaters 500,000 to 1, 300,000 Btu/hr Less Than 30 ppm NOx Up to 87% Thermal Efficiency The High-Efficiency, High-Output Compact Water Heater First Power-Fin production

More information

Tepid Water Delivery System

Tepid Water Delivery System Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI. COBREX Semi-Instantaneous Steam-Fired Domestic Hot Water Generator ENGINEERED DUPLEX ALLOY Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty PVI.com Steam-Fired Domestic Hot Water Generator COBREX

More information

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS s superior ability to absorb and transfer heat makes it the ideal choice for comfortable and efficient heating systems. Since 11 Bradford White Corporation has been dedicated to building the highest quality,

More information

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F Count on Graham for proven reliability. Graham is one of the world s foremost designers and manufacturers of vacuum and heat transfer equipment with over a half-century of proven experience. Our in-house

More information

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation

More information

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage R ISO 9001 COMMERCIAL DOMESTIC HOT WATER GENERATOR Gas, Oil or Combination Gas/Oil 199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage NOW AVAILABLE WITH... NO TANK LINING REQUIRED NO ANODES REQUIRED

More information

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to

More information

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions Portable CNA-Series - Large Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-72 kw (122,800-245,600 BTUs) Certified Lead-Free Design New & Improved Pressure

More information

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual

More information

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications 2.1 GENERAL A. Reference is made to the clause entitled Buy American Act Balance of Payments Program Construction Materials FAR 52.225-9. Notwithstanding a bidder s right to offer identifiable foreign

More information

SECTION HEATING BOILER FEEDWATER EQUIPMENT

SECTION HEATING BOILER FEEDWATER EQUIPMENT SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

RHP120 RHP300 Steam Boiler Series

RHP120 RHP300 Steam Boiler Series Electra Steam, Inc. Phone: 540-662-3811 4407 Martinsburg Pike Fax: 540-665-8101 Clear Brook, VA 22624 email: Sales@reimersinc.com USA web: www.reimersinc.com HEATING POWER kw RHP120 RHP300 Steam Boiler

More information

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating

More information

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR FCU RBVR 1.0 07 25 18 RBVR Vertical Concealed Floor Mount Unit Size 02 03 04 06 08 10 A 23 3/16 [589] 27 3/16 [691] 33 3/16 [843] 43 3/16 [1097] 45 3/16 [1148] 59 3/16 [1503] B 22 ¾ [578] 26 ¾ [679] 32

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project

More information

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries International Reactor Bulletin 1100 Corporation Standard and Custom Reactors for the Chemical Process Industries 2 International Reactor Corporation 521 Kiser Street Dayton, Ohio 45404-1641 Phone: 937-224-4444

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

SECTION AIR COOLED WATER CHILLERS

SECTION AIR COOLED WATER CHILLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2

More information

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal

More information

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions Pre-assembled, freeze-protected safety fixture and SNA heater skid system Bradley Heat Trace S19-304 with SpinTec 54-144 kw (491,300 BTUs) Molded Duragrate and integrated shower pan Temperature overshoot

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

Section K CHLORINATION EQUIPMENT

Section K CHLORINATION EQUIPMENT Section K CHLORINATION EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnish and install chlorination equipment and appurtenances necessary to complete work shown or specified. The equipment is to

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop

More information

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL Manufacturer's Warning To reduce the possibility of injury due to scalding,

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

SECTION FUEL-FIRED DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

15900 HVAC INSTRUMENTATION AND CONTROLS

15900 HVAC INSTRUMENTATION AND CONTROLS 15900 HVAC INSTRUMENTATION AND CONTROLS PART 1 GENERAL - Andover Controls BAS system is the standard for the University, and may be specified as a proprietary item. 1.0 RELATED DOCUMENTS A. Drawings and

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL INSTALLATION AND SERVICE MANUAL Electric Power Water Heater 12kW 162kW NOTE: retain this manual for future reference Installation and service must be performed by Qualified Service Personnel Only. WARRANTY:

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

Operation & Maintenance Manual

Operation & Maintenance Manual (Vertical Model) Semi-Instantaneous Water Heater Steam to Water Design Manual # 9636-0550 Rev. C Operation & Maintenance Manual 340 West 8 th Street Peru, IN 46970 PH: 765-472-3351 FX: 765-472-3968 www.thrushco.com

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

Shipboard Electric Water Heater

Shipboard Electric Water Heater Marine Products Division Model ME Shipboard Electric Water Heater 6-119 Gallon Capacity, Up To 12 KW, Single Phase Marine Approvals United States Coast Guard (USCG) conformance and American Bureau of Shipping

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information