1 Installation Instructions Manufactured Housing Blower Package for Electric Furnaces KMABA----TE KMABA----TE NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. WARNING: Before installing or servicing system, always turn off all power to unit. There may be more than disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death. INTRODUCTION These instructions cover the installation of blower kits with controls into Nordyne/Intertherm/Miller and Evcon/Coleman manufactured housing electric furnaces. After installing the blower packages and controls, the furnace is ready to add an air conditioner or heat pump. Four blower kits are available. Kit Part No. KMABA00TE and KMABA00TE are designed only for Nordyne EEH Furnaces. Kit Part No. KMABA00TE and KMABA00TE are designed for a variety of Nordyne and Evcon furnaces. Refer to Table for kit usage. Refer to Table for kit contents. Nordyne Miller Intertherm Nordyne Miller Intertherm Evcon Coleman FURNACE MODEL Table Kit Usage -ton COOLING APPLICATION -ton EEH KMABA00TE KMABA00TE FEH FEHB FEBA FEBB EEH 00 00A 00 EBxxA KMABA00TE KMABA00TE KMABA00TE KMABA00TE Form: AG-MABA-0 Cancels: New Printed in U.S.A. -97 Catalog No. 9-MA-BA
2 Table Kit Contents DESCRIPTION QUANTITY KMABA00TE KMABA00TE KMABA00TE KMABA00TE 0-v, /-HP Blower Assembly 0-v, /-HP Blower Assembly Control Box Adapter Plate for EEH Furnace Adapter Plate for FEH Furnace Adapter Plate for Coleman 00/00/EB Furnaces Adapter Angle Bracket for Coleman 00/EB Furnaces Transformer Harness for Coleman 00/00/EB Furnaces Harness for Intertherm FEH Harness for Nordyne EEH Orange Wire Connector -X8 Bolt - Nut No. 0 X /-In. Blunt Screw No. 0 X /-In. Pointed Screw Cable Clamp Piggyback Connector Installation Instructions INSTALLATION WARNING: For safe operation, it is the responsibility of the installer to assure that this package is installed in accordance with the furnace manufacturer s recommendations, local codes, good trade practices, and these Installation Instructions. Failure to follow this warning may result in property damage, personal injury, or death form hazards such as fire, smoke, soot, electric shock, or carbon monoxide. WARNING: The use of components not tested in combination with specific makes and models of furnaces may make the equipment in violation of state codes, may create a hazard, and may damage the equipment. In addition, the National Mobile Home Construction and Safety Standards Act and its regulations require the use of components tested or certified by a nationally recognized testing laboratory in all manufactured homes constructed or sold subject to that act. Refer to the appropriate section for your furnace and blower kit. Section Nordyne/Intertherm EEH Furnaces Section Intertherm FEH, FEHB, FEBB, and EEH Furnaces Section Evcon/Coleman 00, 00A, 00, and EBxxA Furnaces
3 SECTION NORDYNE/INTERTHERM EEH FURNACES PROCEDURE REMOVE BWER AND BOX FROM CARTON NOTE: Control box is in carton loose with only motor leads attaching it to blower.. Remove blower from carton. Unit is heavy so exercise care when handling.. Inspect contents for damage.. Remove cardboard packing from blower wheel.. Check for free rotation of blower wheel and center alignment in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until center alignment is achieved.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure it is on flat side of motor shaft.. Check wiring to control box and wire harnesses for pinched or damaged wires. 7. File claim with shipper if shipment is damaged or incomplete. PROCEDURE SELECT PROPER BWER MOTOR SPEED NOTE: It will be necessary to select proper motor speed before attaching blower control box to blower control box base. As shipped, the control box low-speed lead (red) from blower motor is connected to heating terminal # on blower relay, and high-speed lead (black) is connected to cooling terminal # on relay. Change blower leads to appropriate settings as follows:. Refer to Blower Speed Selection Chart and Operation Instructions on Wiring Diagram (Fig. ) or refer to Table.. Determine furnace capacity from furnace rating plate and connect appropriate motor lead to blower relay #. (See Fig. or Table.). Determine capacity of outdoor unit installed and connect appropriate motor lead to blower relay #. (See Fig. or Table.). Blue jumper lead is provided to install between heating terminal # and cooling terminal # on blower relay if and only if heating and cooling speed are the same. Table Blower Speed Selection for Proper Operation of KMABA00TE and KMABA00TE Blowers BWER PACKAGE KIT NO. KMABA00TE KMABA00TE HEATING COOLING Furnace Kilowatt Rating Heating Speed Capacity Cooling Speed 0,000 0,000,000 0,000 0,000,000,000 8,000 PROCEDURE ATTACH BOX TO BWER. Locate control box base which is factory mounted on blower housing.. Insert control box onto base aligning holes in sides of control box and base. (See Fig..). Secure control box to base with screws provided in loose parts bag. (See Fig..) PROCEDURE REMOVE EXISTING BWER FROM FURNACE. Set wall thermostat to lowest setting. Allow furnace to shut off completely.. Turn off electrical circuits to furnace at main circuit box. CAUTION: disconnect. Furnace may be connected to more than power supply. Do not use factory circuit breaker as a. Remove furnace door.. Disconnect the multi-point plugs from furnace control panel.. Remove screws securing existing blower to furnace. Save screws for installation of new cooling blower.. Slide existing blower forward and remove from furnace. PROCEDURE INSULATE FURNACE CABINET Current Nordyne/Intertherm heating only electric furnaces do not have insulation liners. The EEH Furnace will require insulation kit Part No. KMAIK00EI. Refer to Installation Instructions packaged with kit to insulate furnace. PROCEDURE ATTACH NEW COOLING BWER TO ADAPTER PLATE. Orient new cooling blower with adapter plate provided in kit as shown in Fig... Place side flanges of adapter plate on outside of blower housing and end flange of adapter plate inside blower housing wrapper sheet.. Secure blower to adapter plate using No. 0 screws provided in loose parts bag. (See Fig..)
4 OPERATION INSTRUCTIONS: A. BWER IS SUPPLIED WITH HEATING TERMINAL # ON BWER RELAY CONNECTED TO W SPEED MOTOR LEAD (RED) AND COOLING TERMINAL # TO GH SPEED MOTOR LEAD (BLACK). CHANGE MOTOR LEADS TO PROVIDE PROPER BWER SPEED FOR FURNACE AND COIL CAPACITIES AS RECOMMENDED IN BWER SPEED SELECTION CHART. WHEN HEATING AND COOLING SPEEDS ARE THE SAME, CONNECT # AND # TERMINALS. B. A FILTER IS REQUIRED TO PREVENT LINT AND DUST FROM PLUGGING THE COIL. C. CHECK FOR CORRECT BWER OPERATION ON BOTH HEATING AND COOLING. D. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. BWER SPEED SELECTION CHART FURNACE KW RATING TE 0- - TE 0- - HEATING SPEED,000,000 BWER PACKAGE ELECTRIC FURNACE COOLING CAPACITY SPEED 0,000 0//,000,000 8,000 BWER RELAY GREEN YELW BLACK RED BLACK RED WTE RED BLACK BLUE WTE BROWN BWER MOTOR GH VOLTAGE PLUG W VOLTAGE PLUG BROWN GREEN WTE TYPICAL W VOLTAGE HEAT PUMP WIRING BWER W VOLTAGE CONNECTIONS RED YEL WHT GRN OUTDOOR UNIT HEAT PUMP THERMOSTAT R R W O C Y G O C Y W TO COND UNIT Y G R W HEAT COOL TSTAT TERM TE/TE Fig. Wiring Diagram for KMABA00TE and KMABA00TE Blowers A97
5 BOX BASE BWER BOX A977 Fig. Attaching Control Box to Control Box Base PROCEDURE 7 INSTALL BWER/ADAPTER PLATE ASSEMBLY IN FURNACE. Slide blower/adapter assembly into furnace such that adapter plate goes over side and back retaining tabs of furnace until flange drops down and latches under tabs.. Secure with screws removed in Procedure.. Installed blower assembly should appear as shown in Fig.. PROCEDURE 8 MODIFY WIRING. Connect multi-point plugs. (See Fig..) a. Connect motor plug to -pin female plug at control box. b. Connect -pin high-voltage plug from wire harness to -pin high-voltage plug on furnace panel. c. Connect low-voltage plug at control box to plug on furnace panel.. Install wire tie provided in loose parts bag to prevent wires from entering blower housing.. Ensure that all pins make proper connections and that no pins are displaced by another.. Review the Operating Instructions and Wiring Diagram. (See Fig..). Refer to wiring diagrams on blower housing, furnace, and outdoor unit. Connect low-voltage wiring to blower control box, furnace control panel, outdoor unit, and thermostat. NOTE: Blowers require a -wire heating/cooling thermostat for air conditioning, or a heat pump thermostat for heat pumps.. Check all connections for tightness. PROCEDURE 9 APPLY FURNACE LABELS. Fill in data on Furnace/Air Conditioning Accessory label provided in kit listing all model numbers and certification authorities. Use ball point pen.. Install this label in furnace vestibule. BWER BOX WIRING DIAGRAM ADAPTER PLATE A978 Fig. Attaching KMABA00TE or KMABA00TE Blower to EEH Adapter Plate A979 Fig. KMABA00TE or KMABA00TE Blower Installed in Nordyne/Intertherm EEH Furnace
6 NOTE: The HUD requirements are not met unless the data is entered and the label is attached to furnace showing certification authority for the approvals for blower and coils.. If not already attached, apply wiring diagram shipped with kit to blower housing as shown in Fig.. PROCEDURE 0 REASSEMBLE FURNACE AND CHECK FURNACE OPERATION. Close furnace control panel door.. Turn thermostat to OFF position or lowest setting.. Turn furnace system switch on furnace to either ON or HEAT position and reenergize power to unit.. Reinstall furnace door.. Set thermostat to HEAT or COOL setting.. Observe system operation in cooling and heating modes to ensure system is in a safe, reliable operating condition. NOTE: A filter is required to prevent dirt, lint, and dust from plugging the evaporator coil. Use filter kit KMAFK00NFK or equivalent. NOTE: A condensate drain trap is required for all coils installed with electric furnaces. Consult evaporator coil Installation Instructions.
7 SECTION INTERTHERM FEH, FEHB, FEBB, AND EEH FURNACES PROCEDURE REMOVE BWER AND BOX FROM CARTON NOTE: Control box is in carton loose with only motor leads attaching it to blower.. Remove blower from carton. Unit is heavy so exercise care when handling.. Inspect contents for damage.. Remove cardboard packing from blower wheel.. Check for free rotation of blower wheel and center alignment in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until center alignment is achieved.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure it is on flat side of motor shaft.. Check wiring to control box and wire harnesses for pinched or damaged wires. 7. File claim with shipper if shipment is damaged or incomplete. PROCEDURE SELECT PROPER BWER MOTOR SPEED NOTE: It will be necessary to select proper motor speed before attaching blower control box to blower control box base. As shipped, the control box low-speed lead (red) from blower motor is connected to heating terminal # on blower relay, and high-speed lead (black) is connected to cooling terminal # on relay. Change blower leads to appropriate settings as follows:. Refer to Blower Speed Selection Chart and Operation Instructions on Wiring Diagram (Fig. ) or refer to Table.. Determine furnace capacity from furnace rating plate and connect appropriate motor lead to blower relay #. (See Fig. or Table.). Determine capacity of outdoor unit installed and connect appropriate motor lead to blower relay #. (See Fig. or Table.). Blue jumper lead is provided to install between heating terminal # and cooling terminal # on blower relay if and only if heating and cooling speed are the same. Table Blower Speed Selection for Proper Operation of KMABA00TE and KMABA00TE Blowers BWER PACKAGE KIT NO. KMABA00TE KMABA00TE HEATING COOLING Furnace Kilowatt Rating Heating Speed Capacity Cooling Speed 0, ,000 0,000 0,000 0,000 8,000, ,000 PROCEDURE REPOSITION BOX BASE (EEH FURNACES ONLY). Remove screws securing control box base to flat edge of blower housing.. Reposition control box base to curved edge of blower housing aligning holes in control box base with holes in blower housing. (See Fig..). Secure control box base to blower housing with screws previously removed. (See Fig..) PROCEDURE ATTACH BOX TO BWER. Locate control box base on blower housing.. Insert control box onto base aligning holes in sides of control box and base. (See Fig. 7 or 8.). Secure control box to base with screws provided in loose parts bag. (See Fig. 7 or 8.) PROCEDURE REMOVE EXISTING BWER FROM FURNACE. Set wall thermostat to lowest setting. Allow furnace to shut off completely.. Turn off electrical circuits to furnace at main circuit box. CAUTION: disconnect. Furnace may be connected to more than power supply. Do not use factory circuit breaker as a. Remove furnace door.. Pull out furnace safety disconnect from control panel where applicable.. Disconnect multi-point motor plug from furnace control panel.. Remove screws securing existing blower to furnace. Save screws for installation of new cooling blower. 7
8 OPERATION INSTRUCTIONS: A. BWER IS SUPPLIED WITH HEATING TERMINAL # ON BWER RELAY CONNECTED TO W SPEED MOTOR LEAD (RED) AND COOLING TERMINAL # TO GH SPEED MOTOR LEAD (BLACK). CHANGE MOTOR LEADS TO PROVIDE PROPER BWER SPEED FOR FURNACE AND COIL CAPACITIES AS RECOMMENDED IN BWER SPEED SELECTION CHART. WHEN HEATING AND COOLING SPEEDS ARE THE SAME, CONNECT # AND # TERMINALS. B. A FILTER IS REQUIRED TO PREVENT LINT AND DUST FROM PLUGGING THE COIL. C. CHECK FOR CORRECT BWER OPERATION ON BOTH HEATING AND COOLING. D. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. BWER RELAY GREEN YELW WIRE BOX YELW BLACK RED TO COND UNIT RED Y G R W HEAT COOL TSTAT TERM WTE RED BLACK BLUE WTE WTE BWER SPEED SELECTION CHART FURNACE KW RATING TE TE COLE EB FURN HARN INTER FEH FURN HARN BWER MOTOR HEATING SPEED,000,000 BWER PACKAGE ELECTRIC FURNACE BROWN BROWN GREEN BL R B W Y R B B COOLING CAPACITY SPEED 0,000 0//,000 INTER EEH/B FURN HARN,000 8,000 R Y W B R BL TE/TE O O R B W R Y B O TYPICAL W VOLTAGE HEAT PUMP WIRING BWER W VOLTAGE CONNECTIONS RED YEL WHT GRN OUTDOOR UNIT HEAT PUMP THERMOSTAT R R W O C Y G O C Y W Fig. Wiring Diagram for KMABA00TE and KMABA00TE Blowers A980 8
9 BOX BASE Fig. Repositioning Control Box Base for EEH Furnaces A98 BOX BASE BWER BOX BOX BASE BWER BOX A977 Fig. 7 Attaching Control Box to Control Box Base (EEH Furnaces) A98 Fig. 8 Attaching Control Box to Control Box Base (FEH/FEHB/FEBA/FEBB Furnaces) 7. Slide existing blower forward and remove from furnace. PROCEDURE INSULATE FURNACE CABINET Current Nordyne/Miller/Intertherm heating only electric furnaces do not have insulation liners. The FEHB and FEH Furnaces require field-supplied cabinet insulation to prevent condensation when air conditioning is added. The EEH Furnaces require insulation kit Part No. KMAIK00EI to prevent condensation when air conditioning is added. Refer to Installation Instructions packaged with kit to insulate furnace. PROCEDURE 7 ATTACH NEW COOLING BWER TO ADAPTER PLATE. Three adapter plates are shipped with kit. Select appropriate adapter plate for application. a. For EEH Furnaces, use adapter plate shown in Fig. 9. b. For FE Furnaces, use adapter plate shown in Fig. 0.. Orient new cooling blower with adapter plate provided in kit as shown in Fig. 9 or 0.. Place side flanges of adapter plate on outside of blower housing and end flange of adapter plate inside blower housing wrapper sheet.. Secure blower to adapter plate using screws provided in loose parts bag. (See Fig. 9 or 0.) NOTE: Arrangement of control box base, adapter plate, and wiring diagram on blower housing will differ with make and model of furnace. (See Fig. 9 and 0.) PROCEDURE 8 INSTALL BWER/ADAPTER PLATE ASSEMBLY IN FURNACE. Slide blower/adapter assembly into furnace.. Secure with screws supplied in kit or those removed from old blower.. Installed blower assembly should appear as shown in Fig. for EEH furnaces. PROCEDURE 9 MODIFY WIRING. Connect multi-point plug(s). a. For EEH Furnaces, refer to Fig. and wire as follows: (.) Select both the EEH harness (Y-shaped harness) and the FEH harness (with -point plug) provided in kit. 9
10 BWER BOX WIRING DIAGRAM WIRING DIAGRAM BWER BOX ADAPTER PLATE ADAPTER PLATE A978 Fig. 9 Attaching KMABA00TE or KMABA00TE Blower to EEH Adapter Plate A98 Fig. 0 Attaching KMABA00TE or KMABA00TE Blower to FEH/FEHB/FEBA/FEBB Adapter Plate Fig. KMABA00TE or KMABA00TE Blower Installed in EEH Furnaces (.) Connect motor plug to -pin female plug at control box. (.) Connect -pin high-voltage plug from wire harness to -pin high-voltage plug on furnace panel. (.) Connect low-voltage plug at control box to plug on furnace panel. b. For FE Furnaces, wire as follows: (.) Select the FEH harness (with -pin plug) provided in kit. (.) Connect -pin plug from wire harness to plug on furnace panel. (.) Connect -pin plug from wire harness to other plug at control box.. Install wire tie provided in loose parts bag to secure harness to leg of motor mount to prevent wires from entering blower housing.. Ensure that all pins make proper connections and that no pins are displaced by another.. Review the Operating Instructions and Wiring Diagram. (See Fig..). Refer to wiring diagrams on blower housing, furnace, and outdoor unit. Connect low-voltage wiring to blower control box, furnace control panel, outdoor unit, and thermostat. 0 A979
11 NOTE: Blowers require a -wire heating/cooling thermostat for air conditioning, or a heat pump thermostat for heat pumps.. Check all connections for tightness. PROCEDURE 0 REPLACE FURNACE TRANSFORMER Heating transformers on most electric furnaces are not rated for air conditioning and must be replaced with 0-va transformer supplied in kit.. Remove old transformer. If necessary, tag primary and secondary lead locations.. Replace with new transformer supplied in kit. Be sure to reconnect all wiring correctly. PROCEDURE APPLY FURNACE LABELS. Fill in data on Furnace/Air Conditioning Accessory label provided in kit listing all model numbers and certification authorities. Use ball point pen.. Install this label in furnace vestibule. NOTE: The HUD requirements are not met unless the data is entered and the label is attached to furnace showing certification authority for the approvals for blower and coils.. If not already attached, apply wiring diagram shipped with kit to blower housing as shown in Fig. 9 or 0. PROCEDURE REASSEMBLE FURNACE AND CHECK FURNACE OPERATION. Close furnace control panel door.. Reinsert safety disconnect.. Turn thermostat to OFF position or lowest setting.. Turn furnace system switch on furnace to either ON or HEAT position and reenergize power to unit.. Reinstall furnace door.. Set thermostat to HEAT or COOL setting. 7. Observe system operation in cooling and heating modes to ensure system is in a safe, reliable operating condition. NOTE: A filter is required to prevent dirt, lint, and dust from plugging the evaporator coil. NOTE: A condensate drain trap is required for all coils installed with electric furnaces. Consult evaporator coil Installation Instructions.
12 SECTION EVCON/COLEMAN 00, 00A, 00, AND EBXXA FURNACES PROCEDURE REMOVE BWER AND BOX FROM CARTON NOTE: Control box is in carton loose with only motor leads attaching it to blower.. Remove blower from carton. Unit is heavy so exercise care when handling.. Inspect contents for damage.. Remove cardboard packing from blower wheel.. Check for free rotation of blower wheel and center alignment in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until center alignment is achieved.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure it is on flat side of motor shaft.. Check wiring to control box and wire harnesses for pinched or damaged wires. 7. File claim with shipper if shipment is damaged or incomplete. PROCEDURE SELECT PROPER BWER MOTOR SPEED NOTE: It will be necessary to select proper motor speed before attaching blower control box to blower control box base. As shipped, the control box low-speed lead (red) from blower motor is connected to heating terminal # on blower relay, and high-speed lead (black) is connected to cooling terminal # on relay. Change blower leads to appropriate settings as follows:. Refer to Blower Speed Selection Chart and Operation Instructions on Wiring Diagram (Fig. ) or refer to Table.. Determine furnace capacity from furnace rating plate and connect appropriate motor lead to blower relay #. (See Fig. or Table.). Determine capacity of outdoor unit installed and connect appropriate motor lead to blower relay #. (See Fig. or Table.). Blue jumper lead is provided to install between heating terminal # and cooling terminal # on blower relay if and only if heating and cooling speed are the same. PROCEDURE REPOSITION BOX BASE (00/EBXXA FURNACES ONLY). Remove screws securing control box base to flat edge of blower housing.. Reposition control box base to curved edge of blower housing aligning holes in control box base with holes in blower housing. (See Fig..). Secure control box base to blower housing with screws previously removed. (See Fig..) BOX BASE Fig. Repositioning Control Box Base for 00 Furnaces PROCEDURE ATTACH BOX TO BWER. Locate control box base on blower housing.. Insert control box onto base aligning holes in sides of control box and base. (See Fig. or.). Secure control box to base with screws provided in loose parts bag. (See Fig. or.) PROCEDURE REMOVE EXISTING BWER FROM FURNACE. Set wall thermostat to lowest setting. Allow furnace to shut off completely.. Turn off electrical circuits to furnace at main circuit box. A98 CAUTION: disconnect. Furnace may be connected to more than power supply. Do not use factory circuit breaker as a. Remove furnace door.
13 BOX BASE BWER BOX BOX BASE BWER BOX A977 A98 Fig. Attaching Control Box to Control Box Base Fig. Attaching Control Box to Control Box Base (00/00A Furnaces) (00/EBxxA Furnaces). Pull out furnace safety disconnect from control panel where applicable.. Disconnect multi-point motor plug from furnace control panel.. Remove screws securing existing blower to furnace. Save screws for installation of new cooling blower. 7. Slide existing blower forward and remove from furnace. PROCEDURE INSULATE FURNACE CABINET Current Evcon/Coleman heating only electric furnaces do not have insulation liners or coil support shelf in furnace. The 00/00/EB Furnaces require coil support shelf and insulation kit Part No. KMACR00CRI to complete installation and prevent condensation when air conditioning is added. Refer to Installation Instructions packaged with kit. PROCEDURE 7 ATTACH NEW COOLING BWER TO ADAPTER PLATE. Three adapter plates are shipped with kit. Select appropriate adapter plate for application. a. For 00/00A Furnaces, use adapter plate shown in Fig.. b. For 00/EB Furnaces, use adapter plate and adapter plate angle shown in Fig... Orient new cooling blower with adapter plate provided in kit as shown in Fig. or.. Place side flanges of adapter plate on outside of blower housing and end flange of adapter plate inside blower housing wrapper sheet.. Secure blower to adapter plate using screws provided in loose parts bag. (See Fig. or.). For 00/EB Furnaces only, also connect Adapter Plate Angle to Adapter Plate with bolts and nuts supplied in loose parts bag of kit as shown in Fig.. NOTE: Arrangement of control box base, adapter plate, and wiring diagram on blower housing will differ with make and model of furnace. (See Fig. and.) PROCEDURE 8 INSTALL BWER/ADAPTER PLATE ASSEMBLY IN FURNACE. Slide blower/adapter assembly into furnace.. Secure with screws supplied in kit.. Installed blower assembly should appear as shown in Fig. 7 or 8. PROCEDURE 9 MODIFY WIRING. Connect multi-point plug. (See Fig. 7 or 8.) a. Select the 00/00A/00/EB harness (with -pin plug) provided in kit. b. Connect -pin plug from wire harness to plug on furnace panel. c. Connect -pin plug from wire harness to plug at control box.. Install wire tie provided in loose parts bag to secure harness to leg of motor mount to prevent wires from entering blower housing.. Ensure that all pins make proper connections and that no pins are displaced by another.. Review the Operating Instructions and Wiring Diagram. (See Fig..). Refer to wiring diagrams on blower housing, furnace, and outdoor unit. Connect low-voltage wiring on blower control box, furnace control panel, outdoor unit, and thermostat. NOTE: Blowers require a -wire heating/cooling thermostat for air conditioning, or a heat pump thermostat for heat pumps.. Check all connections for tightness. PROCEDURE 0 REPLACE FURNACE TRANSFORMER Heating transformers on most electric furnaces are not rated for air conditioning and must be replaced with 0-va transformer supplied in kit.. Remove old transformer. If necessary, tag primary and secondary lead locations.. Replace with new transformer supplied in kit. Be sure to reconnect all wiring correctly.
14 WIRING DIAGRAM BWER BOX WIRING DIAGRAM BWER BOX ADAPTER PLATE ADAPTER PLATE ADAPTER PLATE ANGLE A988 Fig. Attaching KMABA00TE or KMABA00TE Blower to 00/00A Adapter Plate A98 Fig. Attaching KMABA00TE or KMABA00TE Blower to 00/EB Adapter Plate and Adapter Plate Angle A98 Fig. 7 KMABA00TE or KMABA00TE Blower Installed in 00/00A Furnaces A987 Fig. 8 KMABA00TE or KMABA00TE Blower Installed in 00/EB Furnaces PROCEDURE APPLY FURNACE LABELS. Fill in data on Furnace/Air Conditioning Accessory label provided in kit listing all model numbers and certification authorities. Use ball point pen.. Install this label in furnace vestibule. NOTE: The HUD requirements are not met unless the data is entered and the label is attached to furnace showing certification authority for the approvals for blower and coils.. If not already attached, apply wiring diagram shipped with kit to blower housing as shown in Fig. or.
15 PROCEDURE REASSEMBLE FURNACE AND CHECK FURNACE OPERATION. Close furnace control panel door.. Reinsert safety disconnect.. Turn thermostat to OFF position or lowest setting.. Turn furnace system switch on furnace to either ON or HEAT position and reenergize power to unit.. Reinstall furnace door.. Set thermostat to HEAT or COOL setting. 7. Observe system operation in cooling and heating modes to ensure system is in a safe, reliable operating condition. NOTE: A filter is required to prevent dirt, lint, and dust from plugging the evaporator coil. The filter furnished with 00/00A/00/EB Furnaces is normally adequate. NOTE: A condensate trap is required for all coils installed with electric furnaces. Consult evaporator coil Installation Instructions.
16 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATAG [ ] Packaged Service Training [ ] Classroom Service Training A CAC/BDP P.O. Box 70, Indianapolis, IN 0 agmaba0 Book/Tab: /d /d Catalog No. 9-MA-BA
Installation Instructions
Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation
More informationInstallation Instructions
Installation Instructions Blower Packages For Gas Furnaces KCBBA00TG KCBBA00TG NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION When upgrading a Coleman, Intertherm,
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND
More informationInstallation Instructions
Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper
More informationInstallation Instructions
Coupling Box Kit Cancels: IIK 340M-40-79 IIK 340M-40-88 9-05 Installation Instructions Part No. 320721-765, 330539-751, -752, -753, -754, -755, -756, and -757 NOTE: Read the entire instruction manual before
More informationInstallation Instructions Part No , Part No Part No
Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11
More informationInstallation Instruction
Installation Instruction Upflow Downflow Heating Cooling CC5A Uncased Coil CD5A Cased Coil SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Installation of CD5A Cased Coil A96244 NOTE:
More informationProduct Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL
Product Data CF5A COILS KMABA BLOWERS For Manufactured Homes THE CF5A INDOOR COIL To complete your cooling or heating system, the model CF5A Coil is installed inside your Evcon/Coleman, Nordyne/Miller/Intertherm,
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting
More informationINTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationInstallation Instruction
KGADC0101BVC INTERNAL VENT KIT Installation Instruction NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,
More informationInstallation Instructions
Installation Instructions For Cased Coils Upflow-Downflow Heating-Cooling CK5A CK5B SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation NOTE: Read the entire instruction
More informationInstallation Instructions
Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT
More informationInstallation Instructions
HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.
More informationINSTALLATION INSTRUCTIONS TABLE OF CONTENTS
KSAIF KSAIF0501AAA & KSAIF0601AAA Wi-Fi Interface Kit for Ductless Systems INSTALLATION INSTRUCTIONS NOTE: Read and become familiar with these instructions before beginning installation. TABLE OF CONTENTS
More informationInstallation Instructions
Installation Instructions Fan Coil Units FG3A NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Improper
More informationInstallation Instructions
Heat Exchanger Cell Replacement Kit Cancels: IIK 373L-35-14 IIK 373L-35-17 3-97 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.
More informationInstallation Instructions
---751,---754,---755,---756 Condensing Heat Exchanger Kit Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation,
More informationInstallation Instructions
Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationInstallation Instructions
Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.
More informationinstallation and start-up instructions HUMIDIFIERS AND HUMIDISTAT
installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT HUM Cancels: II 912D-56-3 II HUM-56-1 7-98 MODEL HUMBBLFP1025-A-- FAN-POWERED HUMIDIFIER MODEL HUMBBLBP2018-A-- BYPASS HUMIDIFIER MODEL
More informationInstallation Instructions Part No
Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK
More informationInstallation Instructions
Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...
More informationInstallation Instructions
Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationInstallation Instructions
Evaporator Coil A Coil --- Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationInstallation Instructions
50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric
More informationINSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA
INSTALLATION INSTRUTIONS Low Ambient Kit NASA201LA, NASA401LA These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words
More informationOwner s Information Manual
50EZ---A and 50VT ---A Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump System With PuronR (R ---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Owner s Information
More informationInstallation Instructions
KSALA0201R22 KSALA0301410 Low--Ambient Pressure Switch Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,
More informationTABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.
Installation NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION... 2 Inspect Equipment... 2 Select
More informationOwner s Information Manual
48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)
More informationInstallation Instructions
50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,
More informationInstallation Instructions
CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
More informationInstallation Instructions
CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
More informationFig. 1--Typical Coil Installation
Installation Instructions For Cased Coils Upflow-Downflow Heating-Cooling CK5A,CK5B CK5P SUPPLY _RETURN EVAPORATOR_ COIL_ -'_41 DOWNFLOW FURNACE UPFLOW FURNACE / / _SUPPLY A_2_ Fig. 1--Typical Coil Installation
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the
More informationFig. 1 - Unit PHD4 and WPH4
OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE
More informationFig. 1 - Unit PGD4, PGS4, WPG4
OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.
More informationInstallation Instructions
53DS --- 900 --- --- --- 092 Duct---Free Systems Accessory Power Ventilation Kit for In --- Ceiling Cassette Fan Coil Units Size 018 --- 036 Installation Instructions NOTE: Read and become familiar with
More informationInstallation Instructions
Primary Cell Inlet Panel Kit Installation Instructions Part No. 320720-751, -753, -754, -755, -756, -757,-758, and -760 NOTE: Read the entire instruction manual before starting the installation. This symbol
More informationInstallation Instructions
EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting
More informationResidential Piping and Long Line Guideline
AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...
More informationInstallation Instructions
Electric Heater Kit For use with GB, GP and GT eries Geothermal Heat Pumps KWAEH0101N05 KWAEH0101N10 KWAEH0101F15 KWAEH0101F20 Installation Instructions NOTE: Read the entire instruction manual before
More informationInstallation Instructions
38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes
More informationINTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.
Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can
More informationInstallation Instructions
40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5
More informationPackaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump
Packaged Heat Pumps Owner s Guide to Operating and Maintaining Your Heat Pump NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More information_"RETURN. s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _[_SUPPLY
Installation Instructions Upflow--Downflow CC5A Uncased Coil HeatingmCooling CD5A, CD5P Cased Coil CC5A CD5A/CD5P U "RETURN s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _L [_SUPPLY A_2_ Fig.
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationINSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA
TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,
More informationFAILURE TO FOLLOW THESE INSTRUCTIONS CAN CAUSE FIRE, EXPLOSION, ELECTRICAL SHOCK, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
HKR ELECTRIC HEAT KIT INSTALLATION INSTRUCTIONS AT TENTION INST NSTALLING PERS ERSONNEL As a professional installer, you have an obligation to know the product better than the customer. This includes all
More informationPackaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.
Packaged Air Conditioning Units Owner s Guide to Operating and Maintaining Your Air Conditioner ELECTRICAL SHOCK HAZARD. Failure to follow this warning could result in personal injury, Disconnect power
More informationInstallation Instructions
40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...
More informationInstallation Instructions
CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationKSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual
KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Owner's Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 3 WIRED CONTROLLER FEATURES AND FUNCTIONS... 5 WIRED CONTROLLER
More informationSERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS
SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS TABLE OF CONTENTS 1. Warnings & Component Match-Up............................................ 2 2. Unit Specifications..........................................................
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationInstallation Instructions
40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationInstallation Instructions
CNPHP Cased N s Horizontal Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION...
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD
TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD
TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationUSERS INFORMATION MANUAL
USERS INFORMATION MANUAL DOWNFLOW For Installation In: SINGLE AND TWO STAGE 1. Manufactured (Mobile) Home 2. Recreational Vehicle ELECTRIC FURNACE 3. Modular Homes & Buildings 4. Residential Homes MODELS:
More informationSERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER
SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................
More informationSM Field Installed Electric Heat Kit
SM Field Installed Electric Heat Kit HK050 HK100 HK150 HK200 Installation Manual 8733822029 (2018/07) US 2 SM Series Electric Heat Installation Manual Data subject to change 07.2018 8733822029 Installation
More informationInstallation Instructions
8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting
More informationDLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS
DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationINSTALLATION INSTRUCTIONS
C7BA & C7BH Series Split System Indoor Cased Coils INSTALLATION INSTRUCTIONS IMPORTANT It is your responsibility to know this product better than your customer. This includes being able to install the
More informationC7 Series Split System Uncased Indoor Coils
Installation Instructions C7 Series Split System Uncased Indoor Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS C7BA Series Split System Indoor Cased Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able
More informationInstallation Instructions
HC2 HC3 HOT WATER COILS MULTIPOISE Installation Instructions NOTE: Read the entire installation instructions before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationInstallation Instructions
38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes
More informationImportant Information
Electric Central - & Relay Installation Instructions For Models E(1,)E(H,B) Series The p/n 9098 -wire and p/n 90987 A/C Heat Pump ( to 7 wire) es install with current models of the E1 and E NORDYNE electric
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,
More informationInstallation Instructions
EZXCAB Sizes 016 and 020 High Efficiency Air Filtration System Installation Instructions JAN High Efficiency Air Filtration System Fig. 1 - EZXCAB C04001 NOTE: Read the entire instruction manual before
More informationInstallation Instructions
Installation Instructions Vent/Exhaust Pipe External Trap Kit KGAET0101ETK Table 1 Kit Contents PART DESCRIPTION PART NO. QUANTITY Condensate Trap 308589-402 1 Tee-Vent Fitting (2-in. PVC) 321496-301 1
More informationInstallation Instructions
CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...
More informationFAN UNIT FH4A Sizes 001 thru 004
FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS C8DA Series Split System Uncased Indoor Coils - Downturn IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH
TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationINSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY
INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY EHK05AKN/B, EHK07AKN/B, EHK10AKN/B, EHK15AKF/B, EHK20AKF/B, EHK15AHN, EHK18AHN, EHK09AKCN, EHK25AHCF, EHK30AHCF Safety Labeling and Signal Words DANGER,
More informationOwner's Guide to Operating and Maintaining Your Gas/Electric Unit
Packaged Gas Heat/Electric Cooling Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK. FIRE OR EXPLOSION Failure to follow this warning could result in personal injury,
More informationInstallation Instructions
CRSMKKIT002A00 CRSMKSEN002A00 FIELDINSTALLEDSMOKEDETECTORS FOR MEDIUM ROOFTOP UNITS 15 to 25 TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 SAFETY CONSIDERATIONS... 1 GENERAL...
More informationCAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS
DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location
More informationBESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4
Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...
More informationInstallation in Standard & Variable Speed Indoor Air Handlers IMPORTANT
H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals
More informationInstallation Instructions
CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11
More informationInstallation Instructions
Toshiba Carrier RAV Series Ductless Wind Baffle Fabrication and Installation RAV-SP180AT2-UL RAV-SP240AT2-UL RAV-SP300AT2-UL RAV-SP360AT2-UL RAV-SP420AT2-UL Installation Instructions SAFETY CONSIDERATIONS
More informationInstallation Instructions
40MBD Ducted Style Ductless System Sizes 09 to 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2
More informationYour safety and the safety of others are very important.
VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3
More informationInstallation Instructions
24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationInstallation Instructions
PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 1---1/2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting
More informationINSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS
RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT
More informationElectric Heat Accessory Installation Instructions
Electric Heat Accessory Installation Instructions EBP, EBX, EBV, EBW FVM, FEM, FSM, FSU WARNING Electrical shock hazard. Installation or repairs made by unqualified persons can result in hazards to you
More information