Fundamentals of a gas fire New Zealand. August 2017

Size: px
Start display at page:

Download "Fundamentals of a gas fire New Zealand. August 2017"

Transcription

1 Fundamentals of a gas fire New Zealand August

2 INDEX Fundamentals of a gas fire 3. Ventilation To room space 4. Mechanical ventilation & Smart home connection 5 8. Finish Finish face details Decorative & Space heaters 11. Star ratings Opening sales questions Installation Flame types 21. Gas pressures Aeration Settings Commissioning & Hand over 2

3 Key Elements Decorative Ventilation With any open fronted fire installation, fixed ventilation to the room space is mandatory under the AS/NZS code. Ventilation is required to maintain a balance of pressure between the outside and the room in which the fire is installed. Correct ventilation is achieved by a simple formula. So for a 200mm diameter flue, the radius (r) is 100mm. So Free ventilation area (A) will be 100 x 100 x 22 divided by 7 = 31,428mm. The vents allow the equalisation of pressure within the space where the fire is installed and can be supplied in any number of sizes, quantities and finishes provided they meet the minimum requirement as per the above formula or as specified on the specific units brochure & specifications. Required for open fronted appliances Not required for sealed appliances. Minimum open areas as per instruction booklets (usually starts approx32000mm2) Must be in the room where appliance is located. Is required to enable air to be replaced for what is exiting the flue. Lack of ventilation is a major cause of spillage of flue gases In this installation, ventilation will be brought in via a linear wall diffuser located here. 3

4 Key Elements Decorative Ventilation interlocks All open fronted fires require permanent ventilation within the space that houses the fire. Where open fronted fires are installed into sealed building such as 7 star or Basix applications mechanical ventilation is supplied. A fresh air interlock simply allows the fire control system to operate a motorised damper system via proving switches to ensure the fire only operates when the damper is open and is supplying ventilation to the space. When the fire is off, the damper is closed. CBUS / smart home connection C Bus is a microprocessor based control system for homes and commercial buildings. All Real Flame products that we offer for C Bus operation, are based on a simple on/off process. C Bus control of fires that include remote control functions is not allowed. C Bus is connected to either the GPO which the fire is plugged into, or to the on/off wall switch. 4

5 Finish One of the most common issues with the installation process is correct construction design. There are many aspects to consider during design stage that will make the installation of a gas fire an easy process. Using the previous points, will assist in a smooth process from the sale through to installation to a happy customer. The 4 key considerations are; 1. A design that allows for an approved flue run that can terminate to the atmosphere according to the code. 2. A design that correctly illustrates the framework that will house the fire allowing for the correct clearances. 3. A design that uses the appropriate materials for construction around the fire. 4. A design that considers the aesthetic of the space. The final phase of selection is finish. There are literally hundreds of possible finishes for a Real Flame gas fires. Key Elements Decorative & Space heaters Use your imagination! 5

6 Key Elements - Decorative & Space heaters Finish Decorative fires 6

7 Key Elements - Decorative & Space heaters Finish Decorative fires 7

8 Key Elements Decorative & Space heaters Finish Decorative fires 8

9 Key Elements - Decorative & Space heaters Finish Decorative fires 9

10 Key Elements - Decorative & Space heaters Finish Space Heaters 10

11 Star ratings Space heaters Understanding a STAR LABEL. The STAR LABEL has a number of items on it that tell the customer how efficient the products is and more importantly how it measures against other similar products. Model B Model A The example on the right shows a typical swing tag. This one is the Captiva 900. If compared to a similar fire, you can see the difference in efficiency. 2 STARS 32 Mj/Hr Mj 6.8 kw 4.06 STARS 30 Mj/Hr Mj 6.93 kw The top red band shows how many STARS the fire was given by the testing authority. The number in the RED box is the assumed amount of gas consumed in a typical season. The kw output noted beneath the red box tells the customer how much heat output the fire produces. Model A M/j $ PA Model B M/j $ PA M/j input is ENERGY. A gas log fire burns energy (gas) in the same way a car burns petrol. The combustion process generates power in the form of output (kw). As we combust the gas a given percentage is exhausted in the form of carbon dioxide and water. kw output is POWER. We measure this output to allow us to determine the size of space that we can heat. Typically 1kW of power will heat between 6m2 and 15m2 depending on a large number of factors such as geographic position, aspect, construction style and insulation. 11

12 Opening questions Remember how overwhelmed you were when you first visited the showroom. You just looked from one fire to the next, also remember we can have up to 70 different configurations of fires. Remember how long it took you to get your head around the range of fires. Understand that when a client first walks into our showroom they are also taken back by our amazing range of fires. Understand that they will only be able to concentrate for a few moments, until their mind starts drifting across the range. We must be able to establish why they are here, what their needs are and find a solution quickly and effectively. You have to visualise their situation and come up with a solution. The best way to do this is to ask the following four questions. 12

13 Opening questions 1. Is it a new or existing home? New off the plans or newly constructed.? 2. Is there an existing fireplace or is it a new built fireplace? 3. Why a fireplace? Is it an internal wall? Is it an external wall? Is the home double storey? Is it for charm romance and ambience? Will it be used for primary or supplementary heat or a bit of both.? 4. What Style / design Are they after..? Old world? Traditional? Modern? 13

14 Opening questions In a few moments you will have established the clients needs. Visualise the solution, based on your clients comments. Focus on the solution. - Take them to the visualised fire and demonstrate the fire that fits their needs. - Do a quote (tick all reference boxes Finishes, gas type, flue type) - Give them the appropriate brochure. - Highlight the fire, application and accessories on the specification sheet. Action - Close / Give specifications or details required. - Refer to installer for on site obligation free quote. - Note any follow up in your log / crm. Remember gas fires can only be installed by a licenced gas fitter. Variations from standard approved product. - Every now and again a client will want something out of the ordinary. being made and manufactured in house we have the ability to oblige, however, there is a strict process that has to be adhered to. 1. client must record their request in writing. 2. that request must be submitted to our R and D department for evaluation. 3. R and D will evaluate and advise both you and the client of the outcome For everyone s protection we have adopted the simple rule: if it is not in writing, it is not approved 14

15 Installation Domestic installations vary in type according to aesthetics, construction restraints and budget. Typically we break installs into the following categories; 1. Type 1: A fire that will be installed into an existing masonry fireplace with approved draft. 2. Type 2: A fire installed in conjunction with a prefabricated firebox into an existing masonry fireplace using the firebox flue system to remove waste products (or no flue with ODS) or in a timber frame. 3. Space Heater: Afirefor zero clearance applications where the firebox is installed in a frame that has the appropriate clearances from combustibles or in an existing masonry fireplace. Both applications require a complete flue system. 15

16 Installation Type 1, Appliance Installation. An appliance that consists of an assembly or kit that comprises a burner, simulated fuel effect logs and coals, grate and decorative surround that is designed to be installed in a fireplace of indeterminate specifications and in which the chimney is intended to convey flue products to outside air. An assembly or kit shall have the burner, gas manifold and controls provided as a single assembly and may require assembly of such parts as logs, granules, grate and decorative surround. They should also include an ODS system. (described in next slide) Note: It is critical that the fireplace is a working fireplace in that it draws all combustion products up the chimney and does not spill flue gases in anyway. Fixed permanent ventilation is Required within the room or Space where the fire is situated. 16

17 Installation Type 2, Appliance Installation. An appliance that consists of a complete assembly that includes a fire box/surround and a conventional fabricated flue system. The flue shall be either supplied with the appliance or clearly specified by the manufacturer in the installation instructions. Note: If the type 2 appliance is installed into a fireplace the complete flue system still needs to be installed unless the fire has an ODS system fitted. Fixed permanent ventilation is required within the room or space where the fire is situated. 17

18 Fundamentals Flame types. Decorative fires rely on a flame being slightly rich to create the yellow tall flame. This is controlled by the amount of primary air that is entrained in the burner and the burner design. Decorative burners do have a very low soot level. Primary air burning Air induced by injector Secondary air burning Air supplied around burner This is why it is important the injector is the correct size, the air ventilation is correct, the aeration gaps are set correct and gas pressures are correct. Incorrectly setting the above will result is excessive soot and a very dirty flame. Injectors in conjunction with the pressure determine the gas consumption of the appliance. The higher the pressure, the higher the gas consumption. The larger the diameter, the higher the gas consumption. Injectors also have a vital role in entraining the primary air when burning, this is why a certain size is used and the air openings around the injector are controlled. Calorific value of gases. Natural gas 38.3mj/m3. LPG 98mj/m3. ULPG 118mj/m3. LPG & ULPG compared to Natural gas will use a smaller size injector at a higher pressure to entrain more air into the burner. 18

19 Installation 3. Space Heater Installation. A room sealed appliance that has a minimum efficiency of 70%. The appliance consists of a complete zero clearance firebox and appropriate flue system. Note: If the appliance is installed into a fireplace the complete flue system needs to be installed. 19

20 Fundamentals 20

21 Fundamentals Gas pressures. The measured pressure is usually the burner pressure on the outlet side of the valve. This is important to check to ensure the burner is not over gassed (over gassing will cause sooting and heat damage to componetry and the appliance) or undergased which may cause heating issues or ignition problems. Gas pressures must be checked while the appliance is running. It is good practice when commissioning to ensure the inlet pressure is at least 1.13kPa for Natural gas and 2.75 kpa for LPG. If the inlet pressures are lower the valve will be set incorrectly and when the system pressure increases the burner pressure will increase. Also check that when igniting and or running the inlet pressure does not drop. This is a common sign of undersized piping. Regulator setting. Nat gas 1.13 KPa LPG 2.75kPa Some valves are a on/off valve only and a regulator is fitted prior to the valve. The regulator should be adjusted to give slightly to enable the required burner pressure upto 1.13 / 2.75Kpa pending gas type. The valve should then be set to control the pressure. The regulator will then ensure the valve never supplies more than the nominated rate. 21

22 Fundamentals Aeration settings This controls the primary air entrained into the burner. The injector while injecting gas into the aeration tube entrains air which then mixes in the mixing tube with the gas. When this exits the burner the gas air mixture then burns as the clear blue part of the flame. The quenching or cooling of the flame just prior to complete combustion creates the incandescent effect (yellow flame) and soot. Old Magiglo burner (up to end 2014 Nat gas shown) Current Magiglo burner Landscape burner (Nat gas shown) 22

23 NEW MAGIGLO AERATION SETTINGS ROUND CAPS. 23

24 Commissioning Prechecks Ensure the appliance is installed to suit the room and application. The appliance location is to regulations. The gas supply is correct. The gas supply isolation valve is accessible. Flexihoses are installed to regulations. Not used in inaccessible spaces! The gas supply is checked for leaks. The flue run is correct well sealed, supported, and exit cowl correctly located to meet AS/NZS Gas Installation codes. Ensure the appliance is the correct gas type. Check logs and coals / pebble placement. Burner channel should not be obstructed. Ensure the pilot / spark area has no pebbles / coals within 10mm of electrodes. 24

25 Operation once appliance is running SPILLAGE TESTING Check the inlet gas pressure (recommended appliance is turned off when fitting manometer) Adjust the regulator if required. Check the burner pressure and adjust if required. Note some appliances have a minimum and maximum rate that needs to be checked. Ensure there are no gas leaks. Ensure the flame is even. Ensure the flame colour is correct and not excessively yellow / orange. When starting cold, ensure the flame / pilot is not lifting from burner (mainly space heaters). Check the appliance for spillage of flue gases into the room. To ensure the appliance is operating safely and no combustion products are entering the room. The appliance should be allowed to operate for 5 minutes. Test while the appliance is operating at high (or worst case). Spillage should be checked around seals, louvers and potential room entry points. (eg infill panels on existing fireplaces). Check background levels as there may be other existing sources. Check with and without exhaust fans on. Spillage can be checked using a combustion analyser, co meter. For checking draw on appliances smoke matches. Handover Advise the customer on how to use the appliance. Advise where the electrical isolation switch and gas isolation valve is located. Appliance should be clean, undamaged, and unmarked. 25

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Ignition

More information

SG Burner Only

SG Burner Only SG 700-780-900-1100 Burner Only SG Gas Burner into a Warmington SI Wood Open Fire Installation Guide Only Warmington SI Open Wood Firebox. Warmington SG Gas Burner. Traditional Grate & Burner Pure Grate

More information

REGISTRATION EXAMINATION, NOVEMBER 2016 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, NOVEMBER 2016 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 993 REGISTRATION EXAMINATION, NOVEMBER 06 LICENSED GASFITTER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time

More information

INSTALLATION & OPERATING MANUAL

INSTALLATION & OPERATING MANUAL MAGIGLO SERIES INSTALLATION & OPERATING MANUAL The Magiglo series of decorative fires are suitable to be installed into a masonry or approved prefabricated fireplace and are designed to operate with Natural

More information

Debonaire DUPLO

Debonaire DUPLO Debonaire DUPLO 1200-1600-2000-2400-2800 Custom Fire DUPLO Gas Burner Installation Instructions Flue Liner Promina Board Cladding Non-Combustible Firebox Venting Burner NOTE: TV Above option available

More information

Ignition and controls. Updated August 2017

Ignition and controls. Updated August 2017 Ignition and controls Updated August 2017 1 INDEX Ignitions and controls 3. ODS Oxygen depletion system & Electronic Flame supervision 4. ODS VALVES BM733 5. NOVA VALVES 6. SIT Oxypilot adjustment 7. SIT

More information

Installation Manual EF5000 NZ

Installation Manual EF5000 NZ Installation Manual EF5000 NZ Important: The appliance shall be installed in accordance with; Local gas fitting regulations Municipal building codes AS/NZS 5601.1.1:2010 Gas Installation Any other relevant

More information

Debonaire VIRAGE LH

Debonaire VIRAGE LH Debonaire VIRAGE LH 1200-1600-2000-2400- Custom Fire VIRAGE LH Gas Burner Installation Instructions Flue Liner Firebox Venting Non-Combustible Promina Board Cladding Burner NOTE: T.V. Option Available

More information

----FIREPLACES---- Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces. 24/10/2017 Ver. 15

----FIREPLACES---- Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces. 24/10/2017 Ver. 15 ----FIREPLACES---- Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces 24/10/2017 Ver. 15 1 125mm 125mm Installation Instructions Kemlan Natural Draft Electronic Ignition

More information

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* *Vented appliances refer to natural draft appliances equipped with a barometric draft regulator or Category I appliances equipped with a draft

More information

Installation Manual EF5000 AUS & NZ

Installation Manual EF5000 AUS & NZ Installation Manual EF5000 AUS & NZ This manual is ONLY for fires with a serial No. from 80600 to 80999. Important: The appliance shall be installed in accordance with; Local gas fitting regulations Municipal

More information

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO Combustion Safety RESNET Conference San Antonio, TX February 27, 2006 Presented by Rich Moore Lightly Treading Energy & Design Denver, CO Goals of this session Recognize the need for combustion safety

More information

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 996 CRAFTSMAN EXAMINATION, NOVEMBER 009 GASFITTING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

gas log fires freestanding & inbuilts

gas log fires freestanding & inbuilts gas log fires freestanding & inbuilts why choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire part of your family. In 1979, I founded

More information

GREENFIRE GAS FIREPLACES

GREENFIRE GAS FIREPLACES www.regency-fire.com.au GREENFIRE GAS FIREPLACES LIFETIME W A R R A N T Y 1 Why Choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire

More information

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06 page 1 of 6 VENTING CLEARANCES The vents should not be obstructed and all joints properly fitted. Floors, ceilings and walls must be cut or framed to provide necessary clearance to vents. Metal strippings

More information

Dovre 250 Cast Iron Gas Stove

Dovre 250 Cast Iron Gas Stove Dovre 50 Cast Iron Gas Stove NATURAL GAS AND LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS THIS PRODUCT IS FOR USE ONLY IN GREAT BRITAIN AND IRELAND These instructions are to be left with the customer,

More information

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY Unit 4, Kimpton Trade & Business Centre Minden Road, Sutton, Surrey SM3 9PF Tel: 020 8254 6802 IMPORTANT NOTE Simulated coals, simulated pebbles, simulated logs, simulated driftwood or crushed rock manufactured

More information

gas log fires freestanding & inbuilts

gas log fires freestanding & inbuilts gas log fires freestanding & inbuilts why choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire part of your family. In 1979, I founded

More information

----FIREPLACES---- Installation Instructions Horizon Portrait Power Flue Gas Fireplaces

----FIREPLACES---- Installation Instructions Horizon Portrait Power Flue Gas Fireplaces ----FIREPLACES---- Installation Instructions Horizon Portrait Power Flue Gas Fireplaces Power Flue approved for the following models: SINGLE SIDED MODELS SUITABLE GAS BURNER OPTION 700 PORTRAIT 700 Mk2

More information

----FIREPLACES---- Installation Instructions Horizon Power Flue Gas Fireplaces

----FIREPLACES---- Installation Instructions Horizon Power Flue Gas Fireplaces ----FIREPLACES---- Installation Instructions Horizon Power Flue Gas Fireplaces Power Flue approved for the following models: SINGLE SIDED MODELS CANTILEVER SUITABLE GAS BURNER OPTION 700 Low Line 700 Mk2

More information

ST900 Direct Vent Gas Fireplace Conversion Kit Manual

ST900 Direct Vent Gas Fireplace Conversion Kit Manual ST900 Direct Vent Gas Fireplace Conversion Kit Manual Series 2 Natural Gas for NZ Important: The appliance shall be converted in accordance with; This installation instruction booklet Local gas fitting

More information

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY Unit 4, Kimpton Trade & Business Centre Minden Road, Sutton, Surrey SM3 9PF Tel: 020 8254 6802 IMPORTANT NOTE Simulated coals, simulated pebbles, simulated logs, simulated driftwood or crushed rock manufactured

More information

Gas Log Fires.

Gas Log Fires. 3 Sided Fascia 4 Sided Fascia The Captiva range high efficiency glass Fascia Height: 840mm 930mm fronted fireplace has an impressive Fascia Width: 790mm large scale fire with exceptional heating capacity.

More information

Overview of Gas Range Types

Overview of Gas Range Types Residential Gas Ranges Overview of Types How Carbon Monoxide is Emitted How They Operate Overview of Gas Range Types Rick Karg R.J. Karg Associates www.karg.com November 2001 2001 R.J. Karg Associates

More information

----FIREPLACES---- Installation Instructions Power Flue Horizon Gas Fireplaces. 22/05/2017 Ver. 11

----FIREPLACES---- Installation Instructions Power Flue Horizon Gas Fireplaces. 22/05/2017 Ver. 11 ----FIREPLACES---- Installation Instructions Power Flue Horizon Gas Fireplaces Power Flue approved for the following models: SINGLE SIDED MODELS SUITABLE GAS BURNER OPTION 700 Low Line 700 Mk2 Pebble 700

More information

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:-

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:- THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. THE MODELS COVERED ARE:- For use with Natural Gas:- KENT ESTATE NG, KENT ULTIMA NG For use with Liquid Propane Gas (LPG):- KENT ESTATE LP, KENT

More information

GREENFIRE GAS FIREPLACES

GREENFIRE GAS FIREPLACES www.regency-fire.com.au GREENFIRE GAS FIREPLACES LIFETIME LIMITED W A R R A N T Y 1 Why Choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency

More information

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

POWER VENTER SYSTEM. Model: PVO-300, PVO-600 POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may

More information

Decorative Fuel Effect Appliances

Decorative Fuel Effect Appliances Decorative Fuel Effect Appliances Technical Manual User and Installation Instructions for CUBB22US Available in Natural Gas. 1 Contents Section Pages 1 Unpacking 3 2 Installation Parameters 4 3 Installation

More information

INSTALLATION & OPERATING MANUAL

INSTALLATION & OPERATING MANUAL HOT BOX GAS FIREBOX INSTALLATION & OPERATING MANUAL The Hot Box Gas Firebox is approved to be installed into a masonary fireplace and as a zero clearance firebox and is designed to operate on Natural Gas

More information

Gas Inserts FEATURING

Gas Inserts FEATURING Gas Inserts FEATURING Turn your old inefficent brick fireplace into a desirable high heat output gas fireplace...with a Lopi gas insert featuring technology Step 1. Start by measuring your existing brick

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

THESE INSTRUCTIONS TO BE LEFT WITH THE END USER

THESE INSTRUCTIONS TO BE LEFT WITH THE END USER RIBBON BURNER DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS INSTALLATION, SERVICING & USER INSTRUCTIONS THESE INSTRUCTIONS TO BE LEFT WITH THE END USER Multiglow Fires St Nicholas - at Wade

More information

Evolve 951 & Product specification pages

Evolve 951 & Product specification pages 951 & 1250 Product specification pages SUPPORTING ASTHMA CARE Evolve Specification Evolve 951 Evolve 1250 Inbuilt power flued convection fan heater with electronic temperature control, timers, and remote.

More information

www.regency-fire.com.au CONTEMPORARY GAS FIREPLACES DIRECT VENT GAS FIREPLACES why choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire

More information

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions , EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. FEMC00MN is for use on Natural Gas (G20) at a supply pressure of 20

More information

gas log fires freestanding & inbuilts

gas log fires freestanding & inbuilts gas log fires freestanding & inbuilts why choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire part of your family. In 1979, I founded

More information

Installation guide Compact 2

Installation guide Compact 2 Installation guide Compact 2 Models: RIBF2N/RIBF2L Standard frame Traditional frame Installer, please note: The gas and electrical plate of the unit is not required when attaching the traditional frame,

More information

PVE SERIES POWER VENTER SYSTEM MANUAL

PVE SERIES POWER VENTER SYSTEM MANUAL PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of

More information

POWER VENTER. Model: PVE Series

POWER VENTER. Model: PVE Series POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power

More information

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS 10031 Southern SE Albuquerque NM 87123 505.291.0500 fax 505.291.9317 HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE Before building your first fire, read this warranty and operation manual carefully. By

More information

Rhode Island PIT FIRES

Rhode Island PIT FIRES Rhode Island PIT FIRES HELLO from all of us at Living Flame THE RHODE ISLAND PIT FIRE RANGE So you want a little something special for your yard. We ve created these with you in mind (Besides, being inside

More information

Conventional Flue. Instructions for Installation. For use in NZ (New Zealand). IMPORTANT

Conventional Flue. Instructions for Installation. For use in NZ (New Zealand). IMPORTANT Logic HE Range Conventional Flue Instructions for Installation For use in NZ (New Zealand). IMPORTANT INSTALLATION AND SERVICING MUST ONLY BE CARRIED OUT BY AUTHORISED PERSONNEL. THE OUTER CASING, FRONT

More information

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016 Forced Draft Boiler Flue Gas Venting: Problems & Solutions Presented by Steve Connor and Patrice Gouin January 27, 2016 What Will We Be Covering Today? Pressurized Non-condensing Vent Systems Venting s

More information

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS CRYSTAL FIRES (BOSTON/MIAMI) Cf1 and MANHATTAN Inset Conventional Flue Fire USER INSTALLATION AND SERVICING INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar For use in GB and IE CE THESE INSTRUCTIONS

More information

www.regency-fire.com.au CONTEMPORARY GAS FIREPLACES DIRECT VENT GAS FIREPLACES why choose Regency? An exceptional fire, custom elegance and controllable heat are just a few reasons to make a Regency fire

More information

Clear Installation guide

Clear Installation guide Clear 40010631-0938 ENG Installation guide ENG 1.1 1.2 1.3 A 1.4 1.5 1 < < < < A B 2.1 2.2 2.3 C 2.4 2.5 2 < < < < 3.1 3.2 3-3 3 < < < < Inhoudsopgave 1 Introduction... 6 2 Safety instructions... 6 3 Installation

More information

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME FIREBOXX SYSTEM (NATURAL GAS & LPG) FITTED WITH EVOLUTION PLUS BURNER. FOR DECORATIVE PURPOSES ONLY

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME FIREBOXX SYSTEM (NATURAL GAS & LPG) FITTED WITH EVOLUTION PLUS BURNER. FOR DECORATIVE PURPOSES ONLY Unit 4, Kimpton Trade & Business Centre Minden Road, Sutton, Surrey, SM3 9PF Tel: 020 8254 6802 IMPORTANT NOTE Simulated crushed rock, simulated pebbles, simulated logs, or simulated driftwood, manufactured

More information

VFC Convector Pebble Effect Fires With upgradeable control valve

VFC Convector Pebble Effect Fires With upgradeable control valve VFC Convector Pebble Effect Fires With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) This appliance has been certified for use in

More information

USE & MAINTENANCE INSTRUCTIONS FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES (NATURAL GAS ONLY) FOR DECORATIVE PURPOSES ONLY

USE & MAINTENANCE INSTRUCTIONS FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES (NATURAL GAS ONLY) FOR DECORATIVE PURPOSES ONLY CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRE by IMPORTANT NOTE Simulated coals, or simulated logs, together with simulated black bark, are supplied with this appliance. These are all manufactured from refractory

More information

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety 5.3.1A(2) Page 1 of 2 State of ALASKA, Weatherization Assistance Program Technical Support Document Combustion Safety This document is intended to support in detail the Combustion Safety Test Report. The

More information

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS Model Number: V1/100/A V1/100/B (manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE

More information

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) FOR USE WITH MODEL: OH6FX072DV4 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE

More information

SUPERIOR CAST IRON FIREBOXES MADE IN NEW ZEALAND WOOD FIRES

SUPERIOR CAST IRON FIREBOXES MADE IN NEW ZEALAND WOOD FIRES SUPERIOR CAST IRON FIREBOXES WOOD FIRES 2 SUPERIOR CAST IRON FIREBOXES CONTENTS Freestanding Wood Fires 4 About Masport 6 Traditional Wood Fires 7 Inbuilt Fires 8 Specifications 10 About Wood Fires 11

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

Cleaner & More Efficient Heating Than Ever Before

Cleaner & More Efficient Heating Than Ever Before Cleaner & More Efficient Heating Than Ever Before Clean Air wood heaters are designed and manufactured in Australia especially for Australian winters, and are perfect for cozying up on a cold winters night.

More information

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016 4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016 Section One Task 1 Task 2 Task 3 Task 4 Task 5 Section Two Task 1 Task 2 Task 3 Task 4 Task 5

More information

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE THE NATURAL GAS MODEL IS FOR G20 AT A SUPPLY PRESSURE OF 20mbar THE PROPANE GAS MODEL IS FOR G31 AT A SUPPLY PRESSURE OF 37mbar THESE APPLIANCES

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

Eastside Installation Guidelines and Operating Instructions January 2018

Eastside Installation Guidelines and Operating Instructions January 2018 Eastside Installation Guidelines and Operating Instructions January 2018 Technical details subject to change Please ensure you have the latest specifications Part One Living Flame Livingflame.co.nz INSTALLATION

More information

Gas Inserts & Freestanding FEATURING

Gas Inserts & Freestanding FEATURING Gas Inserts & Freestanding FEATURING Cypress GS2 Direct Vent Gas Fireplace The Cypress features sleek, very clean lines and the choice of three interiors for a unique and timeless presentation of fire

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

INFORMATION FOR TANKLESS WATER HEATERS

INFORMATION FOR TANKLESS WATER HEATERS GAS PIPING INFORMATION FOR TANKLESS WATER HEATERS Details Details regarding regarding properly properly sized sized gas lines lines for for use use with with tankless tankless water water heaters heaters

More information

Direct Vent Gas Inserts & Freestanding FEATURING

Direct Vent Gas Inserts & Freestanding FEATURING Direct Vent Gas Inserts & Freestanding FEATURING Cypress GS2 Direct Vent Gas Fireplace The Cypress features sleek, very clean lines and the choice of three interiors for a unique and timeless presentation

More information

A wood heater that s right for every home! THE FLAME OF THE FUTURE

A wood heater that s right for every home! THE FLAME OF THE FUTURE A wood heater that s right for every home! THE FLAME OF THE FUTURE The fire that burns clean. Kent has developed the ultimate low emission system using the high-tech energy boost combination twin air intakes.

More information

HAWK GAS STOVE. Installation and Servicing Instructions

HAWK GAS STOVE. Installation and Servicing Instructions HAWK GAS STOVE Installation and Servicing Instructions Please leave this instruction booklet with the user after the installation is complete. Leave the system ready for operation and instruct the user

More information

Vaska Logburner. voorbeeld Installation guide

Vaska Logburner. voorbeeld Installation guide Vaska ogburner voorbeeld 40010627-2103 ENG Installation guide ENG 1.1 1.2 1.3 1.4 1.5 1 < < < < 1 Introduction The appliance can only be installed by a competent person in accordance with the Gas Safety.

More information

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These

More information

Manual. Seville & Naples. Gas Fires. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Manual. Seville & Naples. Gas Fires. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners & Installation Seville & Naples Manual Gas Fires PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury

More information

SLIMFIRE 25 FLAME FIRE. Customer Operation & Installation Manual

SLIMFIRE 25 FLAME FIRE. Customer Operation & Installation Manual SLIMFIRE 25 FLAME FIRE Customer Operation & Installation Manual This appliance shall be installed in accordance with: Manufacturers Installation Instructions Local Gas Fitting Regulations Municipal Building

More information

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F. VASKA C11 gas-fireplace user manual Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40 010 458 01.51 DESCRIPTION OF THE FIREPLACE CONTENTS 1 2

More information

Greenfire GFi350L Gas Inbuilt

Greenfire GFi350L Gas Inbuilt Owners & Installation Greenfire GFi350L Gas Inbuilt Manual Models: GFi350LNG-R GFi350LLP-R GFi350LULPG-R PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE LISTINGS AND CODE APPROVALS These gas appliances

More information

Wok Cookers Instruction Manual

Wok Cookers Instruction Manual Wok Cookers Instruction Manual Part No. DC100-09 Single Burner Wok Cooker Part No. DC200-09 Double Burner Wok Cooker IMPORTANT It is IMPORTANT that you read these instructions carefully and understand

More information

ELECTRONIC FIREPLACE DAMPER

ELECTRONIC FIREPLACE DAMPER ELECTRONIC FIREPLACE DAMPER Model: FSE Series The Flue Sentinel Electronic Fireplace Damper is designed to increase the comfort and energy efficiency of residential homes with gas-fired fireplaces. Consisting

More information

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com This session will address the basics of combustion and the latest

More information

VASKA B11. gas -fireplace installation guide

VASKA B11. gas -fireplace installation guide VASKA B11 gas -fireplace installation guide Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40 010 446 01 51 DESCRIPTION OF THE FIREPLACE CONTENTS

More information

INSTALLATION & OPERATING MANUAL

INSTALLATION & OPERATING MANUAL HOT BOX GAS FIREBOX INSTALLATION & OPERATING MANUAL The Hot Box Gas Firebox is approved to be installed into a masonary fireplace and as a zero clearance firebox and is designed to operate on Natural Gas

More information

Solution Installation guide

Solution Installation guide Solution 40011444-1327 ENG Installation guide ENG 1-1 1-2 1-3 1.4 1 < < < < 2.1 2-3 2-4 2 < < < < 3-1 3.2 3-3 3.5 3.6 3 < < < < 4-1 A 4-2 4-3 4 < < < < Dimensions Terminal position Distance (For good working

More information

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION 5traxo Division of Legge Fabheat Ltd Longfield Road, Sydenham, Leamington Spa CV31 1XB Tel. (0926) 882233 Fax (0926) 450846 Registered in England No. 500091 Universal INSTALLATION AND SERVICING INSTRUCTIONS

More information

Contents. Gas Fireplace Types. Wood Fireplace. Electric & Ethanol Fireplaces. Pellet Fueled Appliances. The Original Flame

Contents. Gas Fireplace Types. Wood Fireplace. Electric & Ethanol Fireplaces. Pellet Fueled Appliances. The Original Flame Having a fireplace installed in your home shouldn t be a stressful experience and here at, we re experts at taking your vision and making it happen. There are things as a customer that you can do that

More information

THE INSTRUCTIONS IN THIS MANUAL APPLY TO MASPORT BOSTON (Flued) AND CALGARY (Flueless) GAS FIRES.

THE INSTRUCTIONS IN THIS MANUAL APPLY TO MASPORT BOSTON (Flued) AND CALGARY (Flueless) GAS FIRES. THE INSTRUCTIONS IN THIS MANUAL APPLY TO MASPORT BOSTON (Flued) AND CALGARY (Flueless) GAS FIRES. THE MODELS COVERED ARE:- MG 3000 STD NG, and MG 3000 FLS NG for use with Natural Gas MG 3000 STD LP, and

More information

MULTIPLEX SELF RECUPERATIVE gas burner

MULTIPLEX SELF RECUPERATIVE gas burner Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and

More information

ELECTRONIC FIREPLACE DAMPER

ELECTRONIC FIREPLACE DAMPER ELECTRONIC FIREPLACE DAMPER Model: FSE Low Profile Series The Flue Sentinel Electronic Fireplace Damper is designed to increase the comfort and energy efficiency of residential homes with gas-fired fireplaces.

More information

Gas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING

Gas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING TANKLESS WATER HEATING Gas Piping Facts Information for properly sizing gas lines for use with tankless water heaters and other gas appliances With any gas appliance, it is essential that the gas supply

More information

Studio 3 Steel 2, Glass Fronted with Log-effect fuel bed and Vermiculite lining STUDIO GAS FIRES

Studio 3 Steel 2, Glass Fronted with Log-effect fuel bed and Vermiculite lining STUDIO GAS FIRES Studio 3 Steel 2, Glass Fronted with Log-effect fuel bed and Vermiculite lining STUDIO GAS FIRES STUDIO GAS FIRES A Warm Welcome Nothing creates an inviting atmosphere quite like a Gazco fire. The centrepiece

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

FRANKE DESIGNER GAS COOKTOP 90CM

FRANKE DESIGNER GAS COOKTOP 90CM page 1 of 7 510 880 45 480 Min 50 860 Min 600 SPECIFICATIONS Recommended use Material Colour availability Weight Dimensions Voltage Domestic Stainless Steel Stainless Steel 18.2kg 880 x 510 x 45mm 220-240V

More information

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 Before installation ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the

More information

Gas Fireplaces FEATURING

Gas Fireplaces FEATURING Gas Fireplaces FEATURING Product Overview PRODUCT SPECS MODEL 564 GS2 564HO GS2 Dancing-Fyre 564HO GS2 Ember-Fyre 564HO GS2 Diamond-Fyre 864 GS2 (Clean Face) 864ST GS2 Mj Input High - NG/LPG 21.6 35 35

More information

CHIMNEY INSTALLATION. Technical Bulletin #1

CHIMNEY INSTALLATION. Technical Bulletin #1 Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe

More information

Gas Fireplaces FEATURING

Gas Fireplaces FEATURING Gas Fireplaces FEATURING Product Overview PRODUCT SPECS MODEL 564 GS2 (Clean Face) Dancing-Fyre Ember-Fyre Diamond-Fyre 864 GS2 (Clean Face) 864ST GS2 Mj Input High - NG/LPG 21.6 35 35 35 31 39.5 Low NG

More information

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. 1 MHG Heating Ltd ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual. Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey, KT20 5LR Telephone 08456 448802 Fax 08456 448803

More information

REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9193 REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed

More information

Heat-N-Glo. Installers Guide. Model: 8000TVC

Heat-N-Glo. Installers Guide. Model: 8000TVC Model: 8000TVC Heat-N-Glo Installers Guide Underwriters Laboratories Listed WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,

More information

Importance of a Draught Regulator

Importance of a Draught Regulator Importance of a Draught Regulator The purpose of a chimney (stack) is to generate a draught (draft) that will transport smoke and fumes away from the point of combustion. The chimney design and arrangement

More information

Combustion Sources of Carbon Monoxide. Carbon Monoxide Repairs. Topics Addressed in Session. Why CO can be Harmful Inhalation Time and Symptoms

Combustion Sources of Carbon Monoxide. Carbon Monoxide Repairs. Topics Addressed in Session. Why CO can be Harmful Inhalation Time and Symptoms Affordable Comfort Conference 2002 Saturday, April 20, 8:00 12:00 Rick Karg R.J. Karg Associates www.karg.com April 2002 2002 R.J. Karg Associates Topics Addressed in Session Combustion sources of CO.

More information

Venting of Gas Fired Equipment RV

Venting of Gas Fired Equipment RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Owner s Manual INCLUDES. PARAGON 2016 & PARAGON 2016 Hi IMPORTANT

Owner s Manual INCLUDES. PARAGON 2016 & PARAGON 2016 Hi IMPORTANT Owner s Manual INCLUDES User, Maintenance, Service, and Installation Instructions PARAGON 2016 & PARAGON 2016 Hi Keep this booklet for service log and future reference IMPORTANT This appliance is guaranteed

More information

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE 1 valentine s buildings Bechers drive Aintree racecourse Business Park L9 5ay CF1 L GAS APPLIANCE INSET CONVENTIONAL FLUED GAS FIRE INSTALLATION & USERS INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar

More information