ANALYSIS OF RESIDENTIAL ROOM TEMPERATURE AND OCCUPANT S THERMAL COMPLAINT IN WINTER FIELD SURVEY
|
|
- Virginia Small
- 5 years ago
- Views:
Transcription
1 ANALYSIS OF RESIDENTIAL ROOM TEMPERATURE AND OCCUPANT S THERMAL COMPLAINT IN WINTER FIELD SURVEY M Kojima, T Saito Graduate School of Environmental Studies, NAGOYA University, Chikusa, Nagoya, Japan ABSTRACT To evaluate safety and comfort of residential thermal environment in winter season, field study at 13 residences and questionnaire survey for these occupants were performed around Nagoya city area in Japan. Room temperatures were measured during 14 days, also occupants mentioned thermal complaint for low room temperature and temperature difference among 7 rooms. On the purpose to reveal the relation between room temperatures and recognition of occupants for them, measured room temperatures were compared with thermal complaint. As a result, their awareness for low temperature and room temperature difference were not enough to avoid the risk of heat shock between heated rooms and non-heated rooms. There is the limitation on the accuracy of occupant's recognition for room temperature. Therefore, it is necessary to moderate the room temperature differences in order to reduce domestic thermal related accidents. INDEX TERMS Residence, Temperature difference, Thermal complaint, Occupant, Questionnaire survey INTRODUCTION Residences in Japan have become more air tightened and insulated for resent years to achieve low energy consumption for heating and cooling and to keep their indoor air quality adequate. In the winter season, residents who live on relative moderate climate area in Japan, including Nagoya city area, tend to choose the individual heating method (e.g. a room air conditioner, a gas fan heater) rather than the central system. It is easy method to adopt and apply on each room if necessary but it sometimes brings about large temperature differences between heating rooms and non-heating rooms. When occupants move from one room to another room, they may be exposed to the temperature differences. It is not only discomfort but also raises the risk of domestic thermal related accidents, for example, myocardial infarct. If occupants can recognize the temperature difference exactly, the risk will be decreased. If not, some improvement should be proposed at residential environment itself. Hunt and Gidman (1994) analysed room temperature measured for short term for each 1000 houses, also an interview was conducted on thermal comfort conditions and heating patterns. They concluded that centrally-heated houses ran 3.0 K warmer on average than non-centrally-heated houses. Oseland (1994) compared thermal sensation (TS) and predicted mean vote (PMV) for residences on winter and summer condition. The neutral temperature calculated from TS was 5 C lower than that calculated from PMV in winter and 3 C lower in summer. Tochihara et al (1983) reported thermal sensation of the elderly and the young with the step movement from winter cold condition room to heating room (or opposite way), so that the elderly showed different thermal sensation and physical response from the young. It suggests that the risk of domestic thermal related accidents for the elderly is bigger than that of the young. ASHRAE Standard 55a (1992) gave clear comfort zones for winter and summer conditions. It is so useful to evaluate indoor condition but it does not concern transient indoor condition and movement of occupants that will happen frequently in general residences. Though it has been reported for many measurements of residential room temperature, the relation between room temperature and awareness of occupants is little known. It is necessary to survey residential environment for each room continually and to compare them with recognition of occupants in order to achieve comfort condition and reduce domestic thermal related accidents in winter season. The purpose of this study is to reveal the relation between room temperature and occupant s recognition for that room temperature. RESEARCH METHODS Field study for room temperature To evaluate safety and comfort of residential thermal environment in the winter season, field study at 13 residences 787
2 and questionnaire survey for these occupants were performed around Nagoya city area in Japan. For this purpose, field studies about room temperature and humidity were carried out during two weeks in winter. Amount of calibrated data loggers were set up at living room, kitchen, bedroom, corridor, bathroom, dressing room connected to bath, lavatory, and outside for every residence. To investigate thermal stratification of the room, temperature of floor level + 50mm, +1000mm, +1500mm were recorded by 5minutes interval. In this study, temperature of floor level +1000mm was regarded as the room representative temperature. Table1 shows the profiles of investigated 13 residences. Due to restrict about experimental equipment, 13 residences were divided into two groups. They were chosen in order to cover various residential conditions. Occupants of those residences were instructed to live as well as ordinary times through the measurement period. Table 1. Profiles of investigated 13 residences Group structure apartment/detached past year from construct total floor area (m 2 ) n.of occupants Group1 ( ) wooden detached wooden detached RC apartment RC apartment C, 62%RH * wooden detached outdoor condition RC apartment averaged for 14 days wooden detached RC apartment Group2 ( ) wooden detached unknown wooden detached C, 63%RH * wooden detached unknown outdoor condition Steel detached averaged for 14 days RC detached * based on data of Nagoya weather station Questionnaire survey Questionnaire surveys for these occupants were carried out mainly on thermal comfort for each room temperature. Numbers of occupants on each residence were varied from 1 to 5 persons. At first, occupants were requested to answer how they satisfied with room temperature for above 7 rooms. Occupants expressed them by choosing words from Satisfied Neither satisfied nor unsatisfied slightly unsatisfied unsatisfied. Then, occupants mentioned thermal discomfort caused by room temperature difference when they moved from one room to another room, if there were any discomfort. This movement was defined as direct movement, except for the movement via other room. All occupants who could answer the questions participated in this questionnaire survey. They answered based on actual life at their own residences. After answering, 34 questionnaires were obtained. RESULTS Room temperature and temperature difference Figure 1 shows 5 kinds of analysed room temperature for each room. The ave. temp is average temperature during survey period of 14 days. The daily max. temp and daily min. temp are mean of daily maximum/minimum temperature for 14 days. The morning time temp and evening time temp are mean of 14 days of the average temperature for particular 6 hours, 6:00-12:00 and 18:00-24:00. Except for kitchen, ave. temp is higher than morning time temp, further evening time temp is higher than ave. temp. Occupant s satisfaction with room temperature of living room and kitchen is larger than that of the others. Although bedroom is regarded as one of important rooms for long stay of occupants, occupants complaint about its room temperature as well as corridor, lavatory, dressing room, and bathroom. Due to little adoption heating into corridor and lavatory, the ranges of temperature fluctuation of these rooms are small. Bathing action of occupant raised up daily maximum temperature of bathroom and next dressing room in an instant. Figure 2 shows cumulative distribution of temperature difference among 7 rooms for 13 residences, 14 days. As 21 temperature differences exist among 7 rooms at the same time for each residence, the largest one of them was chosen to be defined as the temperature difference at some point. Occupants may be exposed to this temperature difference when they make a step movement from one room to another room. The largest temperature difference typically arised between two groups, the high temperature group consist of living room and kitchen, and the low temperature group consist of corridor and lavatory. Over 1(K) of temperature difference was observed for 8hrs somewhere in the residence. Figure 3 shows when daily maximum temperature difference occurs through 24 hrs. There are two peaks, larger 788
3 one happened at morning time and the other happened at evening time. Most of daily minimum room temperature was observed at lavatory at morning time, on the other hand, daily maximum room temperature was frequently observed at living room or kitchen at the same period. Therefore, these two situations formed most of daily maximum temperature difference at morning time. Room temperature ( C) 25.0 Thermal complaint for room temperature satisfied living kitchen bedroom corridor lavatory dressing bathroom ave. temp daily max. temp daily mini. temp morning time temp evening time temp Thermal complaint Figure 1. Room temperature (mean of 13 residence, 14 days) unsatisfied (hrs./day) ~ 4.0~ 6.0~ 8.0~ 1~ 12.0~ 14.0~ 16.0~ 18.0~ 2~ Temperature difference among rooms (K) Figure 2. Cumulative distribution of temperature difference among rooms observed frequency :00 6:00 12:00 18:00 daily min. temp daily max. temp daily max. temp difference Figure 3. Observed time of daily maximum temperature difference (13 residence, 14 days) 789
4 ( C) average temp. ( C) daily maximum temp. ( C) daily minimum temp R=-0.44 R=-0.46 R= ( C) Figure 4 Figure 5 Figure 6 morning time temp. R=-0.44 ( C) evening time temp. R=-0.52 Complain vote for room temperature 1: satisfied 2: not either 3: slightly unsatisfied 4: unsatisfied Figure 7 Figure 8 Figure 4-8. Relation between room temperature and thermal complaint vote Thermal complaint for room temperature Figure 4-8 is a scatter plot of room temperature and thermal complaint vote of occupants for it. In this figure, a kind of marker indicates plots of each 7 rooms at one residence, so 13 kinds of markers exist on this figure for 13 residences. Every room temperature is an average of 14 days. Satisfaction of occupant for room temperature is directly proportional to measured room temperature. Correlation coefficients are varied from 0.52 to 0.33, low room temperature causes more thermal complaint obviously. As measured room temperature dropped, thermal complaint of occupants increased. Although occupants seem to be able to recognize room temperature correctly, recognition for daily minimum temp is the lowest (-0.33) among them. That is, thermal complaint of occupants corresponds to the average room temperature rather than the daily minimum room temperature. To Kitchen Corridor Dressing room Living Bedroom Lavatory Living 67% Kitchen From Bedroom Corridor Lavatory Dressing room Bathroom Figure 9. Thermal complaint for step movement 790
5 Figure 9 is a babble chart of occupant s thermal complaint for step movement from a room to another room. The size of a babble means degree of complaint rate. Occupants move from the room on left side of figure, then arrive at the room on upper side of figure. 67% of occupants mentioned complaint at the situation when they would move from living room to dressing room. As shown in Figure 1, there is a large temperature difference between these two rooms. Thermal complaint for step movement tends to be large between heated rooms and non-heated rooms. DISCUSSION There is a high risk of domestic thermal related accidents in winter season on time period when room temperature differences escalate. When occupants move from a heated room to non-heated room, they will be exposed by large temperature differences. As shown in figure 3, room temperature differences escalated at morning time and evening time. It agrees with the fact that domestic thermal related accidents from the statistical data observed frequently at morning and evening. And yet, room temperature difference is nothing but one of many factors that cause domestic thermal related accidents, because they are deeply concerned with particular human actions, ex. bathing, undressing cloths, excretion. Especially, it seems that large thermal complaint for step movement to dressing room contain cold discomfort by undressing their cloths. As most of domestic thermal related accidents occur at bathroom and lavatory in the early morning and evening, large room temperature difference tend to occur between these two rooms and the other rooms. In order to reduce domestic thermal related accidents, occupants should know their environment of room temperatures correctly. However, occupants are not sensitive to daily minimum temperature and large room temperature differences. In figure 4-8, correlation coefficient for daily minimum temperature was the lowest. Although daily largest room temperature difference occurred between high temperature group (living and kitchen) and low temperature group (lavatory and corridor) as seen in figure 1, the highest reply rate of thermal discomfort (67%) in figure 9 was observed in the case that occupant moved from living to dressing room connected to bathroom. From the viewpoint of preventing thermal accidents caused by temperature difference, it should be thought that occupants may underestimate the risk of these accidents because the risk will increase in the morning and evening period, when larger temperature difference exist among rooms in a day. There is the limitation on the accuracy of occupant's recognition for room temperature, therefore, the method to moderate the difference of room temperatures at residence should be necessary. CONCLUSION AND IMPLICATIONS As compared the measured room temperature with the occupant's complaint for the room temperature for 13 residences in winter season, more discomfort was apparently mentioned to the lower room temperature. It seems that the occupant's thermal discomfort is more related to the daily average room temperature would rather than to the daily minimum room temperature or to the average room temperature in the particular period of a day. Temperature differences among rooms increased at the period of early morning and late evening. Since occupants may underestimate these large temperature differences, they should be alleviated in order to decrease the risk of domestic thermal related accidents. ACKNOWLEDGEMENTS This study was supported by TOHO Gas Co.,Ltd. and TOYOAKI Scholarship Foundation. REFERENCES Hunt DRG. and Gidman MI A national field survey of house temperatures, Building and Environment, Volume 17, Issue 2, 1982, Pages Oseland NA A comparison of the predicted and reported thermal sensation vote in homes during winter and summer, Energy and Buildings, Volume 21, Issue 1, ARTICLE1994, Pages ASHRAE ANSI/ASHRAE Standard , Comfort Zones, Atlanta: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Tochihara Y., Ohnaka T., Nagai Y., Tokuda T. and Kawashima Y Physiological Response and Thermal Sensations of the Elderly in Cold and Hot Environments, Journal of Thermal Biology, The Institute of Public Health, Yokohama, Japan, pages
Improvement of Temperatures Stratification caused by Air-conditioner. by means of Ceiling Fan in Classroom
Improvement of Temperatures Stratification caused by Air-conditioner by means of Ceiling Fan in Classroom Natsuka Wakamatsu 1, Yoshihisa Momoi 1, Toshio Yamanaka 1, Kazunobu Sagara 1, Hisashi Kotani 1
More informationComfort Zone Or Acceptable Comfort Zone? : Comparison of Resident Behavior of Operating Air Conditioner According to Charge for Energy
Comfort Zone Or Acceptable Comfort Zone? : Comparison of Resident Behavior of Operating Air Conditioner According to Charge for Energy Suh-hyun Kwon, Nu-ri Bae, Chi-hye Bae and Chungyoon Chun Yonsei University,
More informationSTACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING
STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING H. Kotani, R. Satoh, T. Yamanaka Dept. of Architectural Engineering, School of Engineering, Osaka University, Osaka, Japan ABSTRACT The purpose
More informationSURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS
Proceedings of BS13: SURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS Hiromi Habara 1, Rakuto Yasue 1 and Yoshiyuki Shimoda 1 1 Graduate School
More informationfor family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure
Validation of an Energy Demand Model of Residential Buildings Yohei Yamaguchi 1*, Yoshiyuki Shimoda 1 1 Graduate School of Engineering Osaka University, S4 Building, 2-1 Yamadaoka, Suita, Osaka, 565-871,
More informationSurvey on Cooling Costs and Related Factors for Apartments in an Urban. Area of Osaka
Survey on Cooling Costs and Related Factors for Apartments in an Urban Area of Osaka Noriko Umemiya Xiaoyong Lin Ginjirou Inoue Associate Professor Graduate student Graduate student Osaka City University
More informationA STUDY OF THE IAQ OF RESIDENTIAL BUILDINGS IN SINGAPORE
A STUDY OF THE IAQ OF RESIDENTIAL BUILDINGS IN SINGAPORE NH Wong, BRJ Huang, KW Tham, C Sekhar and DKW Cheong Dept. Of Building, School of Design and Environment, National University of Singapore, Singapore
More informationAMOUNT OF MOISTURE PRODUCTION AND FIELD MEASUREMENT IN DRESSING ROOM
AMOUNT OF MOISTURE PRODUCTION AND FIELD MEASUREMENT IN DRESSING ROOM Yoshihiro Aizawa 1, Shin-ichi Tanabe 2, Kanako Yokoo 2, Kentaro Watanabe 3, and Hideki Amai 4 1 Tokyo Gas Co. Ltd., Tokyo, Japan 2 Waseda
More informationIndoor Thermal Environment of Residential Buildings in Three Cities of China
Indoor Thermal Environment of Residential Buildings in Three Cities of China Hiroshi Yoshino 1 and Haihong Lou 2 1 Prof, Laboratory of Building Environmental Engineering, Department of Architecture & Building
More informationHuman response to thermal environment in rooms with chilled beams
Human response to thermal environment in rooms with chilled beams Arsen Melikov 1, Boryana Yordanova 1, Lyuben Bozkhov 1, Viktor Zboril 1,2, Risto Kosonen 3 1 International Center for Indoor Environment
More informationIndoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials
Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials YUKO TSUKIYAMA 1, NOBUYUKI SUNAGA 2, AKIKO SUZUKI 2, TAMAKI FUKAZAWA 2, YOSUKE
More informationENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN
-9 The 5 World Sustainable Building Conference, Tokyo, 7-9 September 5 (SB5Tokyo) ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN Kahori GENJO Dr.Eng. Shin-ichi MATSUMOTO Dr.Eng
More informationA SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM
Int. Journal for Housing Science, Vol.33, No.4 pp. 249-258, 2009 Published in the United States A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM L. T. Wong, N. K. Fong and W. H. Sui Department
More informationTo describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June
Thermal comfort with radiant and convective cooling systems Risto Kosonen Halton Oy and Aalto University risto.kosonen@halton.com Panu Mustakallio Halton Oy The difference in thermal conditions between
More informationEvaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model
Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model Yoshiyuki Shimoda, Osaka University Takuro Fujii, Osaka University Takao Morikawa, Osaka University Minoru
More informationThermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating
Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating Vladimír Zmrhal Czech Technical University in Prague, Faculty of Mechanical Engineering Corresponding email: Vladimir.Zmrhal@fs.cvut.cz
More informationUse of local convective and radiant cooling at warm environment: effect on thermal comfort and perceived air quality
Use of local convective and radiant cooling at warm environment: effect on thermal comfort and perceived air quality Arsen K. Melikov 1,*, Marcin Duszyk 1, Barbora Krejciríková 1,2, Tomonori Sakoi 3, Jan
More informationThermal Comfort Performance Field Investigation of a Residential Forced- - Air Heating and Cooling System with High Sidewall Supply Air Outlets
Thermal Comfort Performance Field Investigation of a Residential Forced- - Air Heating and Cooling System with High Sidewall Supply Air Outlets Bill Rittelmann, IBACOS Building Enclosure Technology and
More informationResidential Building Walls and Environment in Amman, Jordan
Int. J. of Thermal & Environmental Engineering Volume 3, No. 2 (211) 1-7 Residential Building Walls and Environment in Amman, Jordan S. J. Sulaiman*, N. Beithou Department of Mechanical Engineering, Applied
More informationImpact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams
Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams Risto Kosonen 1, Arsen Melikov 2, Boryana Yordanova 2 and Lyuben Bozkhov 2 1 Halton Oy 2 International
More informationHOT IN HERE: OFFICE OCCUPANT THERMAL COMFORT IN LAWRENCE HALL
GROUP 1 HOT IN HERE: OFFICE OCCUPANT THERMAL COMFORT IN LAWRENCE HALL Daniel Abrahamson Department of Architecture University of Oregon Eugene, Oregon 97403 dva@uoregon.edu Dijon Jones Department of Architecture
More informationVENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING
VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING Rebeca Barbosa 1, Martin Barták 1, Jan L. M. Hensen 1, 2, Marcel G. L. C. Loomans 2 1 Czech Technical
More informationFire propagation over combustible exterior facades exposed to intensified flame in Japan
MATEC Web of Conferences 46, 02002 (2016) DOI: 10.1051/matecconf/20164602002 C Owned by the authors, published by EDP Sciences, 2016 Fire propagation over combustible exterior facades exposed to intensified
More informationExperimental study of fan coil assisting radiant floor heating system
Journal of Scientific Research and Studies Vol. 4(12), pp. 394-401, December, 2017 ISSN 2375-8791 Copyright 2017 Author(s) retain the copyright of this article http://www.modernrespub.org/jsrs/index.htm
More informationHow to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs
How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs 1 ABSTRACT Noureddine Benichou and Ahmed H. Kashef * Institute for Research in Construction National Research Council of Canada
More informationEFFECTS OF EXTREMELY LOW HUMIDITY ON COMFORT AND FATIGUE OF JAPANESE OCCUPANTS
EFFECTS OF EXTREMELY LOW HUMIDITY ON COMFORT AND FATIGUE OF JAPANESE OCCUPANTS Hitomi Tsutsumi 1, Yoshitaka Hoda 1, Hayato Ohashi 1, Yuta Ezaki 1, Junkichi Harigaya 1, Shin-ichi Tanabe 1, and Toshihiko
More informationExperimental study of space cooling using ceiling panels equipped with capillary mats
Experimental study of space cooling using ceiling panels equipped with capillary mats Tiberiu Catalina and Joseph Virgone University of Lyon, France Corresponding email: tiberiu.catalina@insa-lyon.fr SUMMARY
More informationThermal Environment Evaluation in Commercial Kitchens of United States
Downloaded from orbit.dtu.dk on: Jul 25, 2018 Thermal Environment Evaluation in Commercial Kitchens of United States Simone, Angela; Olesen, Bjarne W. Publication date: 2013 Link back to DTU Orbit Citation
More informationGROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE
Conference on Sustainable Building South East Asia, -7 November 27, Malaysia GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE G. REIMANN IEN Consultants,
More informationINDOOR AIR QUALITY IN ENGLISH HOMES - NITROGEN DIOXIDE
INDOOR AIR QUALITY IN ENGLISH HOMES - NITROGEN DIOXIDE SKD Coward, GJ Raw, JW Llewellyn and DI Ross BRE, Watford WD25 9XX, UK ABSTRACT BRE has conducted a national survey of air pollutants in 876 homes
More informationEFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM
- 1 - EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM Shun YOSHIOKA, Hyunyoung KIM, Kazushige KASAI, Daikin Industries,
More informationEnergy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017
Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM 13 th May 2017 0 1 Portion of Inverter Residential Air Conditioners Worldwide (2015) and in Vietnam (Mar 2017) What is "Inverter"?
More informationBNWAT28: Water consumption in new and existing homes
BNWAT28: Water in new and existing homes Version 1.0 This Briefing Note and referenced information is a public consultation document and will be used to inform Government decisions. The information and
More informationDesign Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System
Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,
More informationMODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic
Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING Vladimír Zmrhal 1, Jan Hensen 2 and František Drkal 1 1
More informationEnergy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings
- 1 - Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings Mamoru Hamada, Living Environment Systems Laboratory, Mitsubishi Electric Co., Kamakura, Kanagawa, Japan Naomichi
More informationMultifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use
Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use BuildingEnergy Boston Conference March 8, 2017 Presented by: Andrew Proulx, P.E., LEED AP Neil Donnelly, E.I.T. New Ecology,
More information* Currently, lecturer at the Department of Architecture, The University of Adelaide. Adelaide. South Australia.
THERMAL COMFORT STUDY IN A NATURALLY VENTILATED RESIDENTIAL BUILDING IN A TROPICAL HOT-HUMID CLIMATE REGION Veronica I. Soebarto* and Siti Handjarinto Department of Architecture University of Indonesia
More informationFifteen Years of Dehumidification Results from Heat Pump Water Heaters
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Fifteen Years of Dehumidification Results from Heat Pump Water Heaters
More informationEffect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products
Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products Bakalis S.*, Giannakourou M.C. and Taoukis P. School of Chemical Engineering, National Technical
More informationApplication of Air Source Variable Refrigerant Flow in Cold Climates
PREPARED BY Seventhwave with the assistance of Daikin North America, LLC Masters Building Solutions Application of Air Source Variable Refrigerant Flow in Cold Climates A White Paper March 2015 275-1
More informationThe Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 The Effect of the Ventilation and the Control Mode on the Performance of
More informationA STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET
A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET I. S. Hwang and Y. L. Lee Department of Mechanical Engineering, Kongju National University, Korea E-Mail: ylee@kongju.ac.kr ABSTRACT
More informationA study of Transient Performance of A Cascade Heat Pump System
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 79 (2015 ) 131 136 2015 International Conference on Alternative Energy in Developing Countries and Emerging Economies A study of
More informationEnhancement of COP in Vapour Compression Refrigeration System
Enhancement of COP in Vapour Compression Refrigeration System M. Krishna Prasanna #1 M.E student, Heat Transfer studies in Energy Systems Department of Mechanical Engg., Andhra University Visakhapatnam-530003,
More informationThe thermal performance of green roofs in a hot, humid microclimate
Sustainable Development and Planning VI 475 The thermal performance of green roofs in a hot, humid microclimate U. D Souza F-o-CUS: Focus on Construction Urbanism Sustainability, UAE Abstract Green roof
More informationCan Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1
Can Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1 Jane Colby, Cadmus Group, Boulder, CO Scott Davis, Cadmus Group, Boulder, CO ABSTRACT The New York Energy $mart SM Products
More informationCapillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning
Journal of Physics: Conference Series PAPER OPEN ACCESS Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning To cite this article: Putu Wijaya Sunu et
More informationPerformance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU
Energy and Buildings 39 (2007) 702 708 www.elsevier.com/locate/enbuild Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU Ming-Tsun Ke a, *, Kuo-Liang
More informationCOMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal
By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal Summary Refrigeration air coolers (evaporators) are widely
More informationHUMIDITY CONTROL IN A BASEMENT ART VAULT
16 HUMIDITY CONTROL IN A BASEMENT ART VAULT K. Kelsey Department of Architecture University of Oregon Eugene, OR 97403 kkelsey@uoregon.edu Rebecca Mann Department of Architecture University of Oregon Eugene,
More informationCHAPTER-V RESULTS AND CONCLUSION
CHAPTER-V RESULTS AND CONCLUSION In this chapter, the findings, recommendations and conclusion of the study based on a sample of 500 customers and 50 retailers is presented. Findings The findings of the
More informationENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS
ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS Chainarong Chaktranond *, and Peachrakha Doungsong Department of Mechanical Engineering, Faculty of Engineering,
More informationFeasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to
More informationSimplified Space-Heating Distribution using Radiators in Super-Insulated Apartment Buildings
Simplified Space-Heating Distribution using Radiators in Super-Insulated Apartment Buildings L. Georges*, K. Wen*,c, M.J. Alonso b, M. Berge*, J. Thomsen b and R. Wang c *Energy and Process Engineering
More informationRADIATION BLOCKAGE EFFECTS BY WATER CURTAIN
, Volume 6, Number 4, p.248-254, 04 RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN C.L. Choi Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT Water
More informationInternational Journal of Advancements in Research & Technology, Volume 2, Issue 8, August ISSN
International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August-2013 235 Application of Reliability Analysis for Validating the Results obtained by Failure Mode and Effects Analysis
More informationComparison of Thermal Comfort by Radiant Heating and Convective Heating
Journal of Engineering, Project, and Production Management 2015, 5(1), 26-35 Comparison of Thermal Comfort by Radiant Heating and Convective Heating Shigeru Imai 1 and Shoichi Kojima 2 1 MSc Student, Department
More informationOccupants experiences in dwellings with different LT heating systems
International Energy Agency Energy Conservation in Buildings and Community Systems Occupants experiences in dwellings with different LT heating systems Silvester, Sacha de Vries Ger and Op t Veld, Peter.
More informationSIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY
SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,
More informationComfort and health-indoor air quality
Comfort and health-indoor air quality 1 The human body has a complicated regulating system to maintain the human body temperature constant most of the time, which is 98.6 F (36.9 C) regardless of the environmental
More informationNew Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review
New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review FSEC-PF-454-11 May 2011 Author Carlos Colon Copyright 2011 Florida Solar Energy Center/University
More informationINDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM
INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM Mingjie Zheng Research Laboratory, SANKO AIR CONDITIONING CO., LTD. Nagoya, 450-0003, JAPAN ABSTRACT In large
More informationUBC Social Ecological Economic Development Studies (SEEDS) Student Report
UBC Social Ecological Economic Development Studies (SEEDS) Student Report An Investigation into Optimal Personal Heater Radiant Panel Hui Yang (Sunny) Li, Mariane Hans Alexandre, Steve Qiu University of
More informationExperimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump
Experimental Research of Air Source Heat Pump Frosting and Defrosting in a Double Stage-Coupling Heat Pump Zhiyi Wang Jiansheng Gu Zehua Lu Senior Engineer Engineer Associate Engineer Zhejiang Dun an School
More information1. Select the group that best represents your connection with Eagle Hall.
University of Wisconsin La Crosse Eagle Hall Thermal Comfort Survey Synopsis and Corrective Action Plan - February 203 I. Background UW-La Crosse s (UW-L) Eagle Hall earned LEED Gold certification in May
More informationPerformance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical
More informationseasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former
A study on reducing the energy demand of a liquid desiccant dehumidifier with a radiant panel system Tae Ha Leigh, 1 Dae Uk Shin, 1 Goo Sang Joe, 1 Min Gi Kim, 1 Myoung Souk Yeo, 2 and Kwang Woo Kim 2,*
More informationItaru TAKAHASHI Ph.D 1 Akihiko KUROIWA 2
01-014 The 2005 World Sustainable Building Conference, DEVELOPMENT OF A PASSIVE COOLING STRATEGY USING DOUBLE-ROOFING SYSYTEM WITH RAINWATER SPRAYING AND ITS FIELD TESTING IN TERMS OF THE INDOOR THERMAL
More informationEvaluating Moisture Control of Variable Capacity Heat Pumps in Mechanically- Ventilated, Energy-Efficient Homes.
Evaluating Moisture Control of Variable Capacity Heat Pumps in Mechanically- Ventilated, Energy-Efficient Homes. Charles Withers, Jr. Renewable Energy Systems and Sustainability Conference 2017 Lakeland,
More informationCase study about initial action by disaster prevention staffs at a fire
Case study about initial action by disaster prevention staffs at a fire Author Hiroshi Moriyama 1, 5, Akihiko Hokugo 2, Takeyoshi Tanaka 3, Yoshiteru Murosaki 4 1 Graduate student, Graduate School of Science
More informationThe risk of indoor air pollutants accumulation in the five housing types in Ho Chi Minh City (Vietnam)
The risk of indoor air pollutants accumulation in the five housing types in Ho Chi Minh City (Vietnam) Thuy T. T. Tran 1,5 *, Diem T. K. Nguyen 1,5, Thanh Ng. Tran 2, Phong D. H. Dinh 2, Tan V. Le 1, Olivier
More informationEXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES
THERMAL SCIENCE, Year 2011, Vol. 15, No. 2, pp. 467-475 467 EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES by Krishnasamy SENTHILKUMAR a* and Pss
More informationAMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM
AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM K. Yokoo 1, S. Tanabe 1, Y. Aizawa 2, K. Inagaki 2, D. Kawamata 2, H. Amai 1, K. Watanabe 1, and T. Nishimasu 1 1 Waseda University,
More informationHealthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland
Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0141 ISBN: 978-83-7947-232-1 Prediction of exhaust gas stagnation in common corridor of apartments with gas water heater Takuro Nakamura
More informationEffectiveness of displaying energy consumption data in residential houses Analysis on how the residents respond
6,1 Effectiveness of displaying energy consumption data in residential s Analysis on how the residents respond Tsuyoshi Ueno Osaka University 2-1 Yamadaoka, Suita, Osaka, 565-871 JAPAN tsuyoshi@polux.pwr.eng.osaka-u.ac.jp
More informationComputer Modelling and Simulation of a Smart Water Heater
Computer Modelling and Simulation of a Smart Water Heater Maria Kathleen Ellul University of Malta ellul_maria@yahoo.com Adrian Muscat University of Malta adrian.muscat@um.edu.mt Abstract A computational
More informationDisplacement Ventilation in Classrooms
TWO DIFFUSERS, THE WHITE COLUMNS ON EACH SIDE OF THE WHITEBOARD, PROVIDE COOL SUPPLY AIR TO THE DEMONSTRATION DV CLASSROOM. THE DV CLASSROOM DEMONSTRATION FEATURED A CUSTOMIZED ROOFTOP HVAC UNIT. Displacement
More informationStudy on water conservation by water saving fixtures
Study on water conservation by water saving fixtures T.Kondo(1), S. Iwamoto(), N.Ichikawa(3), M.Kamata() (1) tkondo@kanagawa-u.ac.jp, ()iwamos1@kanagawa-u.ac.jp (3) nichi@js7.so-net.ne.jp, () kamata@arch.t.u-tokyo.ac.jp
More informationDistribution systems in apartment buildings
Article Distribution systems in apartment buildings Halldor Kristjansson, Danfoss A/S www.danfoss.com Halldor Kristjansson, Danfoss A/S Published at the 11th International Symposium on District Heating
More informationModeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room
Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Y. Momoi 1, K. Sagara 1, T. Yamanaka 1 and H. Kotani 1 1 Osaka University, Graduate School of Eng., Dept.
More informationEffect of Insulation on the Growth of Radish Plants- Cultivated Radish ( Raphanus sativus L.) Danielle Griggs, Meher Pandher, Avni Mehta, Meghan Royle
Effect of Insulation on the Growth of Radish Plants- Cultivated Radish ( Raphanus sativus L.) Danielle Griggs, Meher Pandher, Avni Mehta, Meghan Royle Section 1 June 10th, 2013 Mr. Fusco 1 Abstract: Research
More informationAalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016
Downloaded from vbn.aau.dk on: april 09, 2019 Aalborg Universitet CLIMA 2016 - proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols Publication date: 2016 Document Version Publisher's
More informationMonetization of Thermal Comfort in Residential Buildings
Monetization of Thermal Comfort in Residential Buildings Xia Fang, Marcus V. Bianchi, Craig Christensen, National Renewable Energy Laboratory ABSTRACT Building energy simulations can help us determine
More informationThe Urban Park Soundscape in Mountainous Cities:A case study in Chongqing
The Urban Park Soundscape in Mountainous Cities:A case study in Chongqing Heng Li 1,2 ; Hui Xie 1,2 ; Jian Kang 2,3 1 Faculty of Architecture and Urban Planning, Chongqing University, Chongqing, 400045,
More informationSmart Defrost Control for Refrigeration System
Smart Defrost Control for Refrigeration System 1 V. Bagyaveereswaran, 2 S. Shiva Subramanian and R. Anitha 3 1,2, School of Electrical Engineering, Vellore Institute of Technology (VIT University), Vellore
More informationPERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR
PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR Hiroshi Miyazaki 1, Hiromasa Tanjyoh 2, Kengo Suzuki 3, Tomoaki Iwami 4 1 New cosmos electric, co., ltd., Osaka, 543-0036,
More informationMathematical Simulation of Longan Fruit Drying
Mathematical Simulation of Longan Fruit Drying Aree Achariyaviriya, Somchart Soponronnarit and Jirawan Tiansuwan ABSTRACT The objectives of this study were to develop a mathematical model and to simulate
More informationHot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump
Available online at www.sciencedirect.com Procedia Engineering 8 (2011) 165 170 2 nd International Science, Social-Science, Engineering and Energy Conference 2010: Engineering Science and Management Hot
More informationPREDICTION OF THE ENERGY DEMAND IN THE JAPANESE RESIDENTIAL SECTOR IN 2030 BY RESIDENTIAL ENERGY END-USE MODEL
Proceedings of BS21: PREDICTION OF THE ENERGY DEMAND IN THE JAPANESE RESIDENTIAL SECTOR IN 23 BY RESIDENTIAL ENERGY END-USE MODEL Ayako Taniguchi 1,2, Takuya Inoue 1, Masaya Otsuki 1, Yohei Yamaguchi 1,2,
More informationRESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT
IGC 29, Guntur, INDIA RESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT K. Ilamparuthi Professor and Head, Division of Soil Mechanics and Foundation Engineering, Anna University, Chennai 25, India.
More informationEMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA
EMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA Thamer Ahmad Mohammad, Abdul Halim Ghazali, Megat Johari Megat Mohd. Noor Department of Civil Engineering, Faculty of Engineering,
More informationExperimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential
More informationScholars Research Library. The Role of Plant Clinic in Protecting Vertical Urban Green Spaces in Tehran
Available online at www.scholarsresearchlibrary.com Annals of Biological Research, 2011, 2 (3) :255-261 (http://scholarsresearchlibrary.com/archive.html) ISSN 0976-1233 CODEN (USA): ABRNBW The Role of
More informationPrediction of Soil Infiltration Rate Based on Sand Content of Soil
Agricultural Engineering Research Journal 3 (): 0-4, 013 ISSN 18-3906 IDOSI Publications, 013 DOI: 10.589/idosi.aerj.013.3..1109 Prediction of Soil Infiltration Rate Based on Sand Content of Soil 1 1 Majid
More informationIT S HOT UP HERE! A STUDY OF THERMAL COMFORT IN THE LILLIS BUSINESS COMPLEX 4TH FLOOR OFFICES
IT S HOT UP HERE! A STUDY OF THERMAL COMFORT IN THE LILLIS BUSINESS COMPLEX 4TH FLOOR OFFICES Martha Bohm M.Arch Candidate 2006 University of Oregon Eugene, OR 97403 Will Henderson M.Arch Candidate 2006
More informationPERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203
PERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203 SLAC-PUB-15356 January 2013 Michael Woods SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo
More informationComparative Study of Technological Trend between DAIKIN and Panasonic in the Field of Air Conditioner
Comparative Study of Technological Trend between DAIKIN and Panasonic in the Field of Air Conditioner Nhivuong Pham, Yoshitoshi Tanaka Tokyo Institute of Technology, Management of Technology Dept., Tokyo,
More informationMEASURE AND VERIFY SAVINGS OF REFRIGERATOR RECYCLING PROGRAM. Final Report Draft #3 August Prepared for: Sacramento Municipal Utility District
MEASURE AND VERIFY SAVINGS OF REFRIGERATOR RECYCLING PROGRAM Final Report Draft #3 August 2007 Prepared for: Sacramento Municipal Utility District Prepared by ADM Associates, Inc. 3239 Ramos Circle Sacramento,
More informationComparative Study of Indoor Environment in Residential Buildings in Hot Humid Climate of Malaysia
Comparative Study of Indoor Environment in Residential Buildings in Hot Humid Climate of Malaysia M. I. Mohd Hafizal, and Y. Hiroshi, T. Goto Abstract There s a lack in understanding the indoor climate
More information