LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Size: px
Start display at page:

Download "LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:"

Transcription

1 COMMERCIAL GAS OILER Series Gas Water or Steam MH: 400-,860 Efficiency 85.% Net Load Range: Hot Water 80-, MH / Steam 975-7,40 Sq. Ft. COMMERCIAL GAS OILER APPLICATIONS INCLUDE: Apartment uildings Commercial uildings Schools and Other Institutions Multiple oilers Indirect-Fired Water Heating And Much More Versatile combustion control systems Made with Weil-McLain quality

2 DESIGN ADVANTAGES Cast Iron Sections Section Seal sections are made of durable cast iron for long life. It s not uncommon for Weil-McLain cast iron boilers to last 35 years or more. Modern elastomer sealing rings in the port openings assure a watertight seal. ecause of the elasticity of the seals (unlike metal push nipples), they fill any gap caused by imperfections in the port openings, misalignment of sections, or expansion and contraction. Sections are not face ground; the tough outer skin is retained to protect against corrosion. The sections are studded with heat pins that cause the hot gases to swirl about, scrubbing the entire surface for greater heat transfer and maximum operating efficiency. Combined with short draw rods, sealing rings also permit faster section assembly. Lugs and sockets assure proper section alignment during assembly; the machined surfaces of the port openings control the compression ratio of the rings. Sealing Rope Rear Cleaning Sealing rope between the sections assures a permanent, gastight seal. When installed, the rope is visible between sections so the boiler can be checked for tightness. Sealing rope a standard feature of Weil-McLain commercial boilers allows for expansion and contraction of the sections, is impervious to heat and moisture, will not crack and will last the life of the boiler. Removing the rear jacket panel and steel cleanout plates expose the flue passages for inspection and cleaning. Factory-Assembled ase and urners The insulated, galvanized steel base houses the gas manifold and one-piece, high tempurature aluminized steel burners. These burners feature efficient performance, excellent flame characteristics, and quiet ignition and extinction. urners provide fixed primary air no adjustment required for approved gases. One burner/base assembly and one gas train are furnished for the -4 through, and two each for the -3 through 3.

3 FEATURES ADVANTAGES ENEFITS 85.% combustion efficiency saves energy. The is the highest efficiency cast iron atmospheric gas boiler available. Exceeds efficiency requirements of ASHRAE 90.. Cast iron sections for corrosion resistance and long life. Compact design saves valuable space only 50⅜ high, allowing more headroom for piping and venting. Patented section sealing method, short draw rods and sealing rope section speed assembly to reduce installation time. Extra-large 9 top port opening forms an internal header for better water circulation. Large steaming area assures rapid generation of dry steam. AGA design certified for natural and propoane gas. Ratings certified by Air-Conditioning, Heating and Refrigeration Institute (AHRI) for natural and propane gas. Factory-assembled gas train located within the boiler jacket. (Except for all IRI boilers and - through 3 boilers with CSD-/FM.) All -6 through 3 boilers (except for all IRI and -) are capable of low-high-low or staged firing with an additional operating limit control. 3 Factory-assembled base and burners reduce installation time. Simplified piping. The largest steam boiler requires only two risers. uilt-in air separator in water boilers. Air is diverted to the expansion tank through a tapping next to supply outlet. Steel jackets with durable powdercoat finish in WeilMcLain blue completely insulated designed for fast installation. 0 Year Limited Heat Exchanger Warranty. Covers cast iron sections.

4 IR I 33 RI - I 5 CS D- -3 &F M SD - CS 3 D C D- 5 CS 3 AG - A AG 3 A & -0 FM AG 6A & FM AG 4A& 5 FM De s of cript M Co ajor ion mp on en ts COMUSTION CONTROL SYSTEM OPTIONS Manual Main Shutoff Valve Diaphragm Gas Valve w/reg. & Pilot Takeoff Diaphragm Gas Valve Diaphragm Gas Valve Stage w/regulator Motorized Gas Valve w/actuator (On/Off) Low Gas Pressure Switch High Gas Pressure Switch Normally Open Solenoid Vent Valve Manual Leak Checking Gas Valve Leak Test Cock 4 3 Pilot Shutoff Cock Pilot Solenoid Valve Pilot Regulator UCS Control Module Flame Guardian Control System CSD Control Panel WMC A Control Panel WMC A Control Panel For detailed information: Page 5 Page 6 Page 7 OPTIONAL WFFP CONTROL PANEL FOR STANDARD (AGA) AND CSD- SYSTEMS FOR 6-3 PANEL FEATURES 4 Main flame failure lockout. 4 indicator lamps: call for heat, pilot proven, main flame proven, and flame failure (8 lamps on WFFP - panel). Isolated alarm contact to indicate flame failure. Power-on switch, fuse(s), and terminal strip. Optional flame failure alarm bell.

5 STANDARD COMUSTION CONTROL SYSTEMS STANDARD (AGA) AND FM CONTROL SYSTEMS FOR 4-5 UNIVERSAL CONTROL SYSTEM FEATURES: One Weil-McClain UCS ignition control module and wire harness are furnished as standard equipment with each base assembly. On a call for heat, the UCS produces a spark to ignite the pilot. When the pilot flame is proven, the main gas valve opens with a built-in, slow opening soft ignition. In the event the pilot is not proven during a timed trial for ignition, the UCS control system will provide 00% shutoff. After a timed 5-minute delay, another ignition sequence will automatically be initiated. The control system has been certified by AGA and all components are UL Listed. FACTORY-ASSEMLED GAS TRAIN: The gas train allows for fast and easy installation. A slowopening, soft ignition, high capacity, combination gas valve is used on the 4-5 boilers. STANDARD (AGA) CONTROL SYSTEMS FOR 6-3 AND FM CONTROL SYSTEMS FOR 6-0 WFG FLAME GUARDIAN CONTROL SYSTEM FEATURES: A pre-wired WFG control system consisting of a mounting plate, two Weil-McLain UCS control modules and terminal block are furnished as standard equipment with each base assembly. On a call for heat, the pilot proving control module provides a spark to ignite the pilot. When the pilot flame is proven, the first stage of the two-stage gas valve opens and all burners light on low fire. When the main flame sensor proves carryover, the second stage of the gas valve opens and the burners go to high fire. In the event the pilot or main flame is not proven during a timed trial for ignition, the WFG control system will provide 00% shutoff. After a timed 5-minute delay, another ignition sequence will automatically be initiated. The control system provides multiple ignition trials. The control system design has been certified by AGA and all components are UL Listed. LOW-HIGH-LOW FIRING: 6-3 boilers can provide low-high-low firing with the addition of a water temperature or steam pressure control. FACTORY-ASSEMLED GAS TRAIN: The gas train allows for fast and easy installation. A dual gas valve train has an on/off diaphram valve and a low-high-low regulated gas valve. 5

6 ADDITIONAL COMUSTION CONTROL SYSTEMS CSD- SYSTEMS FOR 5 CONTROL SYSTEM FEATURES: A pre-wired control panel with one ignition control module, a manual reset relay with indicator light and a terminal block are furnished as standard equipment with each base assembly. On a call for heat, the control module produces a spark to ignite the pilot. When the pilot flame is proven, the combination gas valve opens with a built-in, slow opening soft ignition. Upon two consecutive pilot flame failures, the control module will trip the manual reset relay and illuminate the red lockout light. The lockout condition(s) should be corrected before pressing the red reset button to reset the boiler. The control system has been certified by AGA and all components are UL Listed. CSD- SYSTEMS FOR 6-0 CONTROL SYSTEM FEATURES: A pre-wired control panel with one pilot-proving module, one main flame proving module, a manual reset relay with indicator light and a terminal block are furnished as standard equipment with each 6- boiler. For 30, two pre-wired control panels are provided, one for each base. On a call for heat, the pilot-proving module, one main flame proving module, a manual reset relay with indicator light and a terminal block are furnished as standard equipment with each 6- boilers. For 3-0, two prewired control panels are provided, one for each base. Upon two consecutive pilot flame failures or on failure to sense main flame, the control module will trip the manual reset relay and illuminate the red lockout light. The lockout condition(s) should be corrected before pressing the red reset button to reset the boiler. For 3-0, the control systems for each base will operate independently of each other. The control system has been certified by AGA and all components are UL Listed. 6

7 CSD- AND FM CONTROL SYSTEMS FOR -3 AND IRI CONTROL SYSTEMS FOR 5-3 CONTROL SYSTEM FEATURES: A pre-wired WMC control panel is furnished as standard equipment. The gas train is located outside the boiler jacket. On a call for heat, the pilot control circuit produces a spark and opens the pilot solenoid allowing the pilot to ignite. For 3-3, the universal ignition control then produces a spark to ignite the pilot on the second base. After the pilot(s) has been proven, the flame safeguard control energizes the main flame circuit allowing the main burners to ignite at low fire. The main pilot is then de-energized and the main flame sensor proves the main burner operation at low fire. For 3-3, the pilot on the second base continues to burn during the boiler on cycle. The flame safeguard control then energizes the downstream gas valve allowing the boiler to fire at high fire. If the pilot or main flame are not proven during the start-up sequence, then the flame safeguard control will lock out on safety. A red indicator light and alarm bell will energize. The lockout condition should be corrected and then the red reset button should be pressed to restart the boiler. The control system will permit a normal start up after an automatic 5-minute delay. The control system has been certified by AGA and all components are UL Listed. WMC CONTROL PANEL FEATURES: Proven main flame with interrupted pilot for main base; pilot is extinguished after 0-second trial for ignition. For two-base boilers, the second base has an intermittent pilot; the pilot on second base continues to burn during boiler on cycle. Pre-purge timer to provide 5-minute enforced wait after flame failure. Flame failure alarm bell. 7 Five indicator lamps: power on, call for heat, pilot on, main flame on, and flame failure. High-low fire control terminals. Low-high-low fire may be provided with a water temperature or steam pressure control. Flame safeguard primary control. Power-on switch, pilot-on switch, main-flame-on switch, alarm silencer switch, fuse and terminal strip.

8 PIPING CONNECTIONS WATER OILERS PIPING NOTES: Alternative Piping-for -4 through only: If desired, all three piping connections (supply, return and expansion tank) can be taken off same end of boiler. Supply and return sizes in table below for water boilers refer to minimum size of pipe connected to boiler for 0 or higher temperature drop between supply and return. Recommended Minimum Pipe Sizes (0 Rise Through oiler) oiler Model Pipe Size Supply and Return -4 " -5 ½" -6 through 8 3" -9 through 6 4" -7 through 3 5" STEAM OILERS Recommended Minimum Pipe Sizes For Single Risers Riser A Header H -4 through 8 4" 4" " -9 through 5" 5" ½" - 6" 6" ½" oiler Model Equalizer J Recommended Minimum Pipe Sizes For Dual Risers 8 oiler Model Riser A Header H Equalizer J -3 through 5 4" 4" 6" 4" -6 through 9 5" 5" 6" 4" -0 through 3 6" 6" 8" 4"

9 STANDARD, ADDITIONAL AND OPTIONAL EQUIPMENT STANDARD EQUIPMENT, ALL UNITS: Cast iron sections Insulated extended jacket Aluminized steel collector hood(s) and draft hood(s) Control transformer (0/4v) Factory-assembled burner and base unit(s): One-piece aluminized steel burners Gas manifold Aluminized steel base panels Hi-temp insulated board Wiring harness: junction box and pre-wired flexible conduit STANDARD EQUIPMENT, -4 and 5: Intermittent electronic ignition systems (UCS): Intermittent ignition control module Electronically supervised pilot burner with ignition electrode and flame rod Wire Harness STANDARD EQUIPMENT, -6 thru 3: Flame guardian panel with flame rectification electronic control system for each base assembly: Pre-wired control panel - Terminal block - Two ignition control modules having integral spark generators - Intermittent electronic ignition pilot system - Electronically supervised pilot burner with ignition electrode and flame rod - Main flame sensor rod STANDARD EQUIPMENT, WATER OILERS: Combination operating and high limit temperature control ( -4 thu 0 only) Operating temperature control ( - thru 3 only) High limit temperature control ( - thru 3 only) Combination pressure temperature gauge 30 PSI ASME relief valve-side outlet uilt-in air eliminator in end sections Probe-type low water cutoff, PS-85-0 (packaged only) STANDARD EQUIPMENT, STEAM OILERS: Operating pressure control High limit pressure control Compound presure-vacuum gauge Gauge cocks, glass and guards 5 PSI ASME relief valve-side outlet Float-type low water cutoff, MM no. 6 LWCO 9 ADDITIONAL EQUIPMENT WFFP control panels ( -6 thru 3) WMC control panels ( -5 thru 3) Probe-type low water cutoff, ps-85-0 (non-packaged water only) Factory-assembled sections ( -4 thru 4 only) Fire-tested packaged unit ( -4 thru 4 only) ½" Inspection tappings with brass plugs two for each section 80 PSI working pressure test of sections Water level controls and low water cutoffs Low-high-low firing ( -6 thru only) Stage firing ( -3 thru 3 only) Energy management control systems (CP panels) IRI, FM and CSD- control systems Natural gas to propane gas conversion kit W-M and PLUS indirect-fired water heaters W-M Maxiflo pool heaters W-M brazed plate heat exchangers WFFP CONTROL PANEL EQUIPMENT STANDARD: WFFP - Panel ( -6 Thru ) WFFP - Panel ( -3 Thru 3) 30-second time delay relay (two on WFFP -) Two 4-volt DPDT relays (four on WFFP -) Terminal block Fuse (two on WFFP -) Toggle switch Four Indicator lamps (eight on WFFP -) ADDITIONAL: Alarm bell and transformer for remote indication of flame failure Alarm bell panel mounted WMC CONTROL PANEL EQUIPMENT STANDARD: WMC -A panel ( -5 thru ) WMC -A panel ( -3 thru 3) Motorized gas train Interruptible pilot (intermittent pilot for adjacent base and additional control module) Pre-wired control panel: - Flame sefeguard primary control - Pre-purge control timer - Relay(s) - Terminal block - Fuse (two on WMC -A) - Four toggle switches - Five indicator lamps - Alarm bell

10 DIMENSIONS Front View Right View Dimensions (inches) Model Left View A C W Draft Hood Outlet(s) Number & Size " -5 3 ½ 6 -" " ½ 36 -" " ½ 46-4" " ½ 56-6" " ½ " ½ 7 -"/ -4" " ½ 37½ 8-4" ½ " "/ -6" " ½ 47½ 0-6" ½ " ½ -6" " Notes: () For 4-3-return tapping size is 5" (qty. ) and supply tapping size is 6" (qty. ). () Gas trains on all IRI boilers and -3 for CSD- & FM are located outside the boiler jacket. Allow additional clearances as required. 0

11 CONTROL TAPPING TALE Location Left End Right End Size Steam Water (4) C C ¼" oiler Drain oiler Drain D & D D3 & D4 ½" Gauge Glass (3) E & E E3 & E4 " Low Water Cutoff (3) Optional Low Water Cutoff Left View E E3 " Pressure Operating & Limit Controls & Pressure Gauge F F " Limit Control () To Expansion Tank or Automatic Air Vent () G G 3/4" Operating Control () H & H () H3 & H4 () ⅜" Tri-cock J J " Steam Relief Valve & Skim Tapping K K ½" Water Relief Valve and Skim Tapping Combination Pressure & Temperature Gauge () M & M M3 & M4 " Optional Low Water Cutoff (3) Optional Low Water Cutoff Right View M M3 " Firing Rate Control (when used) Firing Rate Control (when used) or Probe Low Water Cutoff Notes: () Available on special request only. () Must be on same side as supply to system. (3) Must be on same side as steam equalizer piping. (4) Additional controls for water boilers may be placed in supply piping. oiler Model Notes: No. of Gas Trains () Rated pressure for -3 CSD- & FM is 5.5" W.C. Standard AGA CSD- & FM IRI 5" W.C. 7" W.C No. of Gas Trains 5" W.C. 7" W.C No. of Gas Trains 5.5" W.C. 7" W.C. -4 " -5 " " " " ¼" " -6 ¼" " ¼" " ¼" " -7 ¼" " ¼" " ¼" " -8 ¼" " ¼" " ½" ¼" -9 ¼" " ¼" " " ¼" -0 ½" ¼" ½" ¼" " ¼" - " ¼" " ¼" " ½" - " ¼" " ¼" " ½" -3 ¼" " ¼" " " ½" -4 ¼" " ¼" " " ½" -5 ¼" " ¼" " " ½" -6 ¼" " ¼" " " ½" -7 ¼" " ¼" " " ½" -8 ½"/ ¼" ¼"/ " ½"/ ¼" ¼"/ " ½" ½" -9 ½" ¼" ½" ¼" ½" " -0 ½"/ " ¼" ½"/ " " ½" " - " ¼" 3" " 3" " - " ¼" 3" " 3" " -3 " ¼" 3" " 3" "

12 oiler Model Number () Heating Medium Input MH () AHRI Certified Ratings (3) Gross Output MH () Net Rating Steam MH () oiler N.P. RATINGS STEAM Sq. Ft. Steam oiler Water Content Gallons Steam (to waterline) Approx. Shipping Weight Lbs. Assembled lock Weight Complete Packaged oiler Weight Water (gallons) Models P (4) Chimney reeching Size (I.D) (inches) (5) -4-S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam S Steam oiler Model Number () Heating Medium Input MH () AHRI Certified Ratings (3) Gross Output Net Rating MH () RATINGS WATER Assembled lock Weight Complete Packaged oiler Weight Water MH () oiler H.P. oiler Water Content Gallons Approx. Shipping Weight Lbs. Models P (4) Chimney reeching Size (I.D.) Inches (5) -4-W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water W Water Notes: () Add to boiler number S" for Steam, W" for Water. () MH = thousands of TU/hour. (3) Net AHRI ratings are based on net installed radiation of sufficient quantity for building requirements. Do not add on for normal piping and pickup. Water boilers are rated at 80 psig maximum working pressure. Water ratings are based on piping and pickup allowance of.5. Additional allowance should be made for gravity hot water systems or unusual piping and pickup loads. Ratings shown are for elevations up to,000 feet. For ratings above,000 feet, reduce at rate of 4 percent per 000 feet above sea level. (4) Sling length is 5 feet; per boiler. (5) A twenty-foot (0') chimney height may be used in most cases, based on using a six-foot (6') length of connector for breeching of the size shown from the nearest draft hood outlet to the chimney or vent with not more than one () standard sloping-type 90 elbow. Consult the National Fuel Gas Code, ANSI Z3., for actual sizing. If individual vertical vents are to be used, each vent diameter should be the same size as the respective draft hood outlet and the height may be reduced to five feet (5') measured above the draft hood outlet. WM5_RO_07

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 19A. mith PRESSURIZED WET BASE SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Replacement parts EG/PEG

Replacement parts EG/PEG Replacement parts EG/PEG Table 13 EG/PEG replacement parts A B Left hand end section with heater opening (Pattern No. 1814) Left end section without heater opening(pattern No. 1813) Right hand end section

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Propane gas CSD-1 Control System Part Number 550-110-682/0304 Please read this page first Hazard definitions To the installer... The following terms

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications Engineer: Project Name: Project Location: Contractor: PPLICTION: Modular Gas Fired Steam heating boiler for indoor installations.

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

CSD-1 COMMERCIAL BOILER CONTROLS

CSD-1 COMMERCIAL BOILER CONTROLS SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project

More information

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system EGH Series 5 Gas-Fired Boilers Control Supplement EGH-105 to EGH-125 Natural gas CSD-1 control system For propane boilers, install EGH liquefied petreoleum (propane) gas conversion kit in addition to following

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler VICTORYVSPH VICTORY VSPH Cast-iron sealed combustion, direct vent gas boiler Cast-iron sealed combustion, direct vent gas boiler THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION, RELIABILITY AND ECONOMY.

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Series 8H. Cast Iron Gas Fired Commercial Water Boiler Series 8H Cast Iron Gas Fired Commercial Water Boiler to 0 MBH Input Over 8% Efficient 0 or 0 PSI Cast Iron Sectional Design Atmospheric Vent Modular/Multiple Boiler Configurations Available Series 8H

More information

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON Mills 00A mith Mills 00A Smith CAST IRON OIL, GAS OR COMBITION GAS/OIL COMMERCIAL BOILER/BURNER 00AR STEAM GAUGE OPERATING CONTROL MODULATING CONTROL HI LIMIT PRESSURE CONTROL 0" STEAM DRUM TEST COCK /"

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes

More information

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents LGB Gas fired boiler Control Supplement LGB-6 to LGB-23 Series 2 Propane gas Universal Control System Contents I. New installation... 2 II. Existing installation... 4 III. Gas piping... 5 IV. Wiring...

More information

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters High to Mid-Efficiency Residential & Commercial Heating Solutions Innovative. Efficient. Dependable. Dunkirk. Boilers and Indirect Water Heaters Helix VLT Series Gas-Fired Condensing Boiler UP TO 95 %

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY. VICTORYVSPH Cast-iron Cast-iron sealed sealed combustion, combustion, direct direct vent vent gas gas boiler boiler THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY. VICTORYVSPH

More information

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20

More information

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON mith Mills Mills 00A OIL OR GAS CAST IRON BOILER/BURNER Smith CAST IRON 00A- - Gas I=B=R Ratings: Gross Output 7,19 to 1, FRONT VIEW WITH INDUS COMB BURNER SIDE VIEW WITH INDUS COMB BURNER SIDE VIEW -

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

Boiler Manual. Series 3 Water & steam boilers for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup

Boiler Manual. Series 3 Water & steam boilers for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup 94 Series 3 Water & steam boilers for use with Gas, Light Oil, & Gas/Light Oil Fired Burners Boiler Manual Installation Startup Maintenance Parts For additional information, refer to.. Burner specification

More information

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 502C-902C SUGGESTED SPECIFICATIONS Catalog No.: 6000.601A Effective: 07-12-18 Replaces: 10-31-16 FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Unmatched high efficiency product selection

Unmatched high efficiency product selection Full Line Catalog Unmatched high efficiency product selection Weil-McLain has a full product line to satisfy every application need. Evergreen: Premium Stainless Steel Award-winning stainless steel with

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER www.weil-mclain.com ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER Water Natural/Propane Gas 80-399 MBH Direct Exhaust/Direct Vent Average Efficiency 94% AFUE HIGH EFFICIENCY CONDENSING BOILER The new

More information

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B BW1, BW2 & BW3 Gas-Fired Water Boilers Series B Product Data MODEL BW1, BW2 Series B MODEL BW3 Series B MODELS BW1, BW2, and BW3 Models BW1 and BW2 Gas-Fired Hot Water Boilers provide fast heat quietly

More information

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners 1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):

More information

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES. VICTORYII Cast-iron, power vent gas boiler VHS SERIES are available in a sealed combustion model VSPH VICTORY BOILERS AN IDEAL REPLACEMENT BOILER FOR OLDER HOMES. A PERFECT BOILER FOR NEW CONSTRUCTION.

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor PHNTM Floor Standing Heating s Phantom-X 399C/500C Residential High Efficiency Gas s PHNTM399C, PHNTM500C Submittal Sheet Wholesaler Job Name Mechanical Contractor Number Gas Type BTU/hr INPUT BTU/hr OUTPUT

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

SERVICE TECHNICIAN ONLY read and follow completely.

SERVICE TECHNICIAN ONLY read and follow completely. Parts list Table 7 Series 3 section and flue collector parts Item Description Part No. A Wide front section (7011) 316-700-245 B C D E Regular intermediate section (7015) Intermediate section w/draw rod

More information

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER ULTRA www.weil-mclain.com SERIES 4 HIGH EFFICIENCY CONDENSING BOILER Water Natural/Propane Gas 80-399 MBH Direct Exhaust/Direct Vent Average Efficiency 94% AFUE HIGH EFFICIENCY CONDENSING BOILER The new

More information

Peerless Boilers. Series MI. Residential Gas Boilers

Peerless Boilers. Series MI. Residential Gas Boilers Peerless Boilers Series MI Residential Gas Boilers Hard work and dedication by skilled employees have made us one of today s top cast iron boiler manufacturers. From the beginning, our main priority has

More information

Boiler Manual. Oil-Fired Steam Boilers. Maintenance Parts. Installation Startup

Boiler Manual. Oil-Fired Steam Boilers. Maintenance Parts. Installation Startup Oil-Fired Steam Boilers Boiler Manual Installation Startup Maintenance Parts This manual must only be used by a qualified heating installer/service technician. BEFORE installing, read all instructions

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

G315/6 Cast Iron Boiler

G315/6 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10 Model C Forced Draft Burners Natural Gas or Propane MODEL C10 MODEL C4 GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7 Telephone: (519) 620-0230 Telefax: (519) 620-0232

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL MODELS: 181-401, 182-400 CATALOG NO. 9300.203 Effective: 01-01-19 Replaces: 06-15-16 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 182, 260, 330, 400 ATMOSPHERIC 181, 261, 331, 401 LOW NOx MODEL

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts Figure 92 Propane conversion kits and instructions Boiler model DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE The WM97+ maintenance kit includes components that

More information

G315/5 Cast Iron Boiler

G315/5 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-5 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

JD Series Cast Iron Commercial Hot Water or Steam Boiler

JD Series Cast Iron Commercial Hot Water or Steam Boiler JD Series Cast Iron Commercial Hot Water or Steam Boiler INSTALLATION, OPERATION & MAINTENANCE MANUAL An ISO 9001-2008 Certified Company Utica Boilers 2201 Dwyer Ave. Utica, NY 13501 Phone: (315) 797-1310

More information

G515/7 Cast Iron Boiler

G515/7 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview Engineering Specifications There shall be provided and installed G515-7 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing with

More information

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Description Model Weil-McLain part number. Vent Termination Kit for 3 Stainless Steel All Replacement parts Figure 96 Miscellaneous parts Description Model Weil-McLain part number Vent Termination Kit for 3" PVC All 383-500-397 Vent Termination Kit for 3" Stainless Steel All 382-200-430 Vent

More information

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler ClearFire Model CFH Horizontal Steam Boiler Startup Guide 750-293 www.cleaverbrooks.com Improper installation, adjustment, service, or maintenance can cause equipment damage, personal injury, or death.

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

MULTIPLEX SELF RECUPERATIVE gas burner

MULTIPLEX SELF RECUPERATIVE gas burner Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and

More information

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work. Buchtel/Perkins Community Learning Center GPD -2007271.15 OSFC Project # 55-7110-9029425 Phase 3 CLC Package Bidding Documents July 1, 2010 SECTION 15513 CONDENSING BOILERS PART I- GENERAL 1.1 RELATED

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

STEAM / GAS APPLICATION GUIDE

STEAM / GAS APPLICATION GUIDE WET-BASE CAST-IRON MODULAR BOILERS Guidelines for the design, purchase and installation of Slant/Fin gas-fired steam modular boiler systems. STEAM / GAS APPLICATION GUIDE CONTENTS Introduction...1 Ratings

More information

COMMERCIAL HYDRONIC HEAT PRESSURE FIRED, WET BASE, OIL, GAS OR COMBINATION. Heating Capacities 667 to 4551 MBH Output V11 SERIES

COMMERCIAL HYDRONIC HEAT PRESSURE FIRED, WET BASE, OIL, GAS OR COMBINATION.   Heating Capacities 667 to 4551 MBH Output V11 SERIES COMMERCIL HYRONIC HET PRESSURE FIRE, WET SE, OIL, GS OR COMINTION V SERIES Heating Capacities 66 to MH Output V SERIES HOT WTER OR STEM Maximum Water Working Pressure: 0 PSI-Water; PSI-Steam Your Heating

More information

G615/11 Cast Iron Boiler

G615/11 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G615-11 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

Attachment A District 1000 Boiler Replacement District 10 Project # Building #

Attachment A District 1000 Boiler Replacement District 10 Project # Building # I. Base Bidding Requirements Attachment A 00 Boiler Replacement This is a Base Bid project; the following describes the Base Bid requirements. Contractors are to provide bids for Base Bid #1. BASE BID

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls... 12a Replacement parts Section assembly... 55 Base... 56 Jacket... 58 Trim... 60 Controls... 61 Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler

More information

Boiler Manual. Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup

Boiler Manual. Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup 88 Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners Boiler Manual Installation Startup Maintenance Parts For additional information, refer to.. Burner specification

More information

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS MODEL ADF/ADFH 300 and 500 FOR INDUSTRIAL & COMMERCIAL APPLICATIONS Model ADF CSA 3.7 ANSI Z83.4 Non-Recirculating Industrial Air Heaters WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR USE IN HAZARDOUS

More information

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18 PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18 Table of Contents Table of Contents.................................................1 Product Selection Guide............................................2

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513

More information

Raypak Residential Products

Raypak Residential Products Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part of replacement part. Results

More information

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT MODBUS AND BACnet MSTP PROTOCOL CASCADING SEQUENCER WITH CASCADE REDUNDANCY 6 INPUTS FROM 750,000 TO 2.0 MILLION BTU/HR UP TO 25:1 TURNDOWN RATIO

More information

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications 2.1 GENERAL A. Reference is made to the clause entitled Buy American Act Balance of Payments Program Construction Materials FAR 52.225-9. Notwithstanding a bidder s right to offer identifiable foreign

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters Low NOx, Quiet, Efficient, Space-Saving Mighty Therm Lo-NOx Greater energy efficiencies as high as 84% are achieved through

More information

15B Cast Iron Gas Fired Boilers For Forced Hot Water

15B Cast Iron Gas Fired Boilers For Forced Hot Water Models 5B05FE 5B070FE 5B0FE 5B0FE 5B5FE 5B70FE 5B5FE 5B5FE 5B5FE 5B Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

High Efficiency Commercial Gas Water Heaters

High Efficiency Commercial Gas Water Heaters High Efficiency Commercial Gas Water Heaters 500,000 to 1, 300,000 Btu/hr Less Than 30 ppm NOx Up to 87% Thermal Efficiency The High-Efficiency, High-Output Compact Water Heater First Power-Fin production

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004 Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates

More information

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO. GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO. GBI 210 3C For a proper installation and in order to receive the best in operating life and efficiency from your

More information

SECTION WATER HEATERS

SECTION WATER HEATERS SECTION 15457 WATER HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete hot water generating system with necessary accessories as indicated on Construction Documents, as specified, and

More information

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Form No. 2300-7 (Rev. 2/99) Gas, il or Dual Fuel Fired Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Originators of the Flexible Water Tube

More information

Please read before proceeding

Please read before proceeding Boiler Manual Please read before proceeding Installer Read all instructions before installing. Follow all instructions in proper order to prevent personal injury or death. Consider piping and installation

More information