1 Continuing Professional Development (CPD) Saving Energy and the Environment with the latest developments in Heat Pipe Technology CIBSE Approved
2
3
4 CONTENTS What is a Heat Pipe Heat Pipes for Energy Recovery Comparison with alternative systems Heat Pipes for Cooling and Dehumidification The benefits of using Water as a Working Fluid Conclusions Questions and discussion
5 What is a Heat Pipe?
6 What is a Heat Pipe? Transferred heat Applied Heat
7 Applications Computer Cooling
8 Working Fluid Refrigerant R134A Operating temperature - 50 C to + 60 C New SPC Water Technology Operating temperature 0 C to C Increased efficiency Completely eco friendly
9 Applications Heat Pipes for Energy Recovery
10 Application Pre-Cool 43 C Intake 33 C 33 C 23 C Extract
11 Double deck AHU with energy recovery heat pipe
12 Horizontal Heat Pipes
13 Alternatives Run around Coils Can be used where ducts are some distance apart. No cross contamination. Summer and winter usage. Pumps and associated power and maintenance requirement. Typical effectiveness 40 45%
14 Alternatives Crossflow plate heat exchanger No cross contamination No moving parts Difficulties with moisture collection and cleaning Bulky, particularly with larger air volumes Typical effectiveness 50 55%
15 Alternatives Thermal wheels Cross contamination of airflows Energy and maintenance for motors belts and sealing bushes Typical effectiveness 70 75% (But requires high latent load) High pressure drops > 200 Pa Specific Fan Power calcs Price
16 Heat Pipes for Energy Recovery Advantages :- High efficiency (R134A 55-60%, Water 60 65%) No Moving parts No direct energy requirement Low Air Pressure drop Zero cross contamination Easy condensation drainage Compact Virtually maintenance free Easy to clean
17 IT RACK IT RACK Applications Data Centres :- Free ambient cooling FAN HEAT PIPE OUTSIDE AIR FAN
18 Applications Heat pipes for Cooling / Dehumidification
19 Heat Pipes For Cooling \ Dehumidification ASHRAE Recommended Safety margin Health Problems Mildew Growth % Relative Humidity
20 Heat Pipes For Cooling \ Dehumidification
21 Heat Pipes For Cooling \ Dehumidification Traditional System Warm humid air, 33 C Saturated air, 18 C Condensation
22 Heat Pipes For Cooling \ Dehumidification Using Reheat Warm humid air, 33 C 12 C Comfortable air, C Condensation Reheat Coil
23 Heat Pipes For Cooling \ Dehumidification
24 Adding a Heat Pipe The heat pipe improves the efficiency of the system by pre-cooling and reheating the air 18 C 33 C 27 C 12 C
25 Heat Pipe Dehumidification wrapped around cooling coil Plan view of cooling coil. Heat Pipe pre-cool Airflow Cooling Coil Heat Pipe re-heat Airflow 33/26 C 27/24.5 C 12/11.8 C 18/14.1 C
26 Heat Pipes For Cooling \ Dehumidification
27
28 Heat Pipes For Cooling \ Dehumidification
29 Heat Pipes For Cooling \ Dehumidification
30 Large Horseshoe Heatpipe
31 Heat Pipes For Cooling / Dehumidification
32 Energy Recovery Software
33 Energy Recovery Software
34 Dehumidification Software
35 Projects Shopping Centre - Dubai
36 Projects Royal mirage Hotel - Dubai
37 Projects - UK British Museum - London Royal Victoria hospital N. Ireland
38 Projects One Peking Rd Hong Kong
39 Projects Ocean Park- Hong Kong
40 Improving IAQ and Energy Saving by using energy efficient Water Heat Pipes D E H U M I D I F I C AT I O N AND ENERGY RECOVERY R E F R I G E R A N T F R E E FOR GREENER BUILDINGS
41 Water Heat Pipes Why should we want to use water as a working fluid?
42 Water Heat Pipes Proven 18% improved effectiveness over refrigerant Greenest working fluid available GWP of Water = 0, R134a = 1430, R410a = 2088 Safe in any environment More cost effective
43 Water Heat Pipes How do we know water is better?
44 Sample Test Result Sample Comparative Test Result for 2 row test piece using R134a and Water Air Velocity (m/s) Working Fluid R134a Water R134a Water (T 1 - T 2 ) (T 4 - T 3 ) Effectiveness (%) % Increase 18.69% 16.77% The comparative results obtained show percentage effectiveness improvements of between 16% and 18%. SPC patented method of manufacture utilising water rather than refrigerant
45 Water Heat Pipes Why do we get better results using water as a working fluid?
46 Water as Working Fluid? High Latent Heat Latent heat is the amount of energy absorbed as a given mass of the fluid changes phase from liquid to vapour. Higher latent heat gives better heat transporting capacity of the working fluid The latent heat of water is approximately 14 times that of R134a, accordingly there is 14 times less mass transfer required to transfer the same heat between the ends of the heat pipe.
47 Water as Working Fluid? High thermal conductivity Better heat transfer for a given temperature differential Reduction in temperature gradient High efficiency
48 Water Heat Pipes How do we get water to boil at below 100 degrees Celsius? I.E Everest?
49 Water as a Working Fluid Boiling Temperature of water at sea level 100 C Boiling temperature of water on Everest 68 C
50 Water Phase Change
51 Water Heat Pipes Internal heat pipe pressure changes with temperature At 20 o C Saturation Vapour Pressure for Water = 0.02Bar R134a = 6 Bar, R410a = 15 bar At 45 o C SVP for water=0.1 bar, R134a = 12 bar, R410a=28 bar
52 Water Heat Pipes What are benefits of using water?
53 Benefits of WHP Better performance results in:- Reduction in number of rows/fpi required Reduction in size/cost Reduced air side pressure drop Lower internal working pressure
54 Benefits of WHP Green and Eco-Friendly Water is harmless to the environment Reduction of carbon footprint in manufacturing heat pipes Water has zero Global Warming Potential (GWP) & Ozone Depletion Potential (ODP) Gain more points in LEED & BREEAM Certification
55 Conclusions Heat Pipes are: Very Efficient conductors of heat Can dramatically increase the amount of moisture removed in humid climates Allow energy recovery with zero cross contamination Reduce running costs, fast pay-back
56 Now Available on Heat Pipes MINIB Trench Heaters Belgravia Fan\Natural Convectors Coil Heat Exchangers Created by BIM Technologies (BIMStore) who are part of the Space Group Created in AutoDesk Revit 2013 by a certified AutoDesk engineer COBie UK 2012, BS1192 and AEC(uk) compliant Links for product information Ductwork, Pipework & Electrical connectors available for MEP projects
57 Thank You Any Questions?
REFRIGERANT AND WATER HEAT PIPES D E H U M I D I F I C A T I O N
www.spcoils.co.uk REFRIGERANT AND WATER HEAT PIPES D E H U M I D I F I C A T I O N AND ENERGY RECOVERY ABOUT SPC About SPC The Company S & P Coil Products Limited is a UK based specialist manufacturer
More informationEnriching Environments
Enriching Environments 2 Enriching Environments We understand the difference an improved internal environment can make 3 Contents 4 5 6 7 8 9 10 11 About us Heating and cooling coils Fan convectors Trench
More informationSolar Heat Pumps Domestic Range
Solar Heat Pumps Domestic Range Who are Quantum? Quantum are the experts in Heat Pump Water Heating technology. Since 1977 we have been developing our patented technology, our products have been tried
More informationEnergy Saving & Eco-Friendly Refrigerant
Technical Seminar Energy Saving & Eco-Friendly Refrigerant Presented By Eva Yim Business Development Director Stephen Cheung Engineering Director Date : Oct 16, 2012 Others 25% Lighting 15% Air Conditioning
More informationHeat pump and energy recovery systems
SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air
More informationLATENT COOLING LEAD. Kecha Thirakomen EEC Engineering Network
Kecha Thirakomen EEC Engineering Network INTRODUCTION Air-conditioning has been advanced from comfort cooling to çquality air-conditioningé, targeting Indoor Air Quality-IAQ. Equipment will not be selected
More informationChilled Water system
Chilled Water system Introduction For large installations the Condenser, Evaporator, Compressor and Expansion device can be purchased as a package unit, known as a Chiller. The usual package consists of
More informationAir Conditioning Inspections for Buildings Condensers
. Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,
More informationHeat Recovery Units. Heat Recovery 1
Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air
More informationCHAPTER 4. HVAC DELIVERY SYSTEMS
CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer
More informationEnergy Use in Refrigeration Systems
2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is
More informationAir Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems
. Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems PRESENTED BY NIRAJ MISTRY aircon@stroma.com Cooling Load The Refrigeration Load Cooling load on refrigeration system
More informationPatent Pending CO 2 OLrac. Blade Server Cooling
Patent Pending 0421232.0 CO 2 OLrac Blade Server Cooling Cooling with CO 2 Carbon dioxide (CO 2 ) is an ideal refrigerant, particularly when considered against ecological and safety criteria. It is natural,
More informationExperimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract
Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant M. Honma, T. Tamura, Y. Yakumaru and F. Nishiwaki Matsushita Electric Industrial Co., Ltd. Living Environment
More informationCustom Air Handler Solutions Custom Units to Meet Your Unique Design Needs
Custom Units to Meet Your Unique Design Needs Engineered for flexibility and performance Contents Horizontal Configuration....1 Horizontal with Standard Economizer Configuration...2 Stacked Configuration...3
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationAir Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems
. Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems PRESENTED BY NIRAJ MISTRY aircon@stroma.com Cooling Load The Refrigeration Load Cooling load on refrigeration system
More informationHEAT PIPES DEHUMIDIFICATION &
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS S&P COIL PRODUCTS LTD. S P C HEAT PIPES FZC HEAT PIPES DEHUMIDIFICATION & HEAT RECOVERY Table of Contents 1 General Introduction... 1 2 Safety Issues...
More informationWhite Paper Dehumidification in Humid Climates - A Theoretical Case Study
White Paper Dehumidification in Humid Climates - A Theoretical Case Study This white paper provides details of a theoretical comparison of operating costs associated with mechanical dehumidification systems
More informationENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou
Condensers ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM A. Hadawey, Y. T. Ge, S. A. Tassou 4 7 8 5 3 2 6 1 Produced by: The Centre for Energy and Built Environment
More informationA refrigeration system for supermarkets using natural refrigerant CO 2
A refrigeration system for supermarkets using natural refrigerant CO 2 A. Campbell 1,2, G. G. Maidment 2 and J. F. Missenden 2 1 Tesco Stores Ltd, Shire Park, Welwyn Garden City 2 London South Bank University,
More informationINTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development
INTRODUCTION Heat Pipe Technology, Inc. Heat Pipe Technology, Inc. (HPT) was founded in 1983. With funding from private investors, and a grant from the Department of Energy. HPT began research on a new
More informationEconomical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ
Economical, Flexible, Advanced Performance Ventilation and Dehumidification for Healthy IAQ CompleVent the Energy Conserving, Cost-Efficient Way to Meet ASHRAE Standards Today s focus on indoor air quality
More informationEXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)
EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a) Abstract- With the recent government regulations, of banning the ozone depleting substances and Kyoto protocol
More informationEVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22
EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22 Ameya P. Shrivastava 1, Choudhari Chandrakishor S. 2 1,2 Mechanical Department, AISSMS College of Engineering, Pune 411001, (India) ABSTRACT HCFC
More informationFACT SHEET 9 Large Air-Conditioning (air-to-air)
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Material on HFC Management Fact Sheets on HFCs and Low GWP Alternatives October 205 FACT SHEET 9 Large Air-Conditioning (air-to-air). Description
More informationNUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A
ISSN: 2250-0138 (Online) NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A RANENDRA ROY a1, MADHU SRUTHI EMANI b AND BIJAN KUMAR MANDAL c abc Department
More informationTrane Performance Climate Changer Air Handlers. An air handler for every need.
Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: designed to optimize your HVAC system. Trane Performance Climate Changer air
More informationIf a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.
Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally
More informationRT-OA TM Rooftop Outdoor-Air (DOAS)
RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...!
More informationspc-hvac.co.uk COIL HEAT EXCHANGERS FOR AIR HEATING AND COOLING ENERGY EFFICIENT SOLUTIONS
spc-hvac.co.uk COIL HEAT EXCHANGERS FOR AIR HEATING AND COOLING ENERGY EFFICIENT SOLUTIONS ABOUT SPC ABOUT SPC THE COMPANY S & P Coil Products Limited is a UK based specialist manufacturer and supplier
More informationETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming
ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI
More informationthe Greenest Foodsafe Refrigeration in the World
GASTRO ECOPRO the Greenest Foodsafe Refrigeration in the World Foster Refrigerator has just launched its Eco range of Premier and Pro Cabinets, which offers a staggering saving of up to 50% in energy usage.
More informationSPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview
SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview As in residential buildings the purpose of mechanical conditioning and ventilation is to maintain air quality and thermal comfort in buildings, with
More informationCoIL HEAT EXCHAngERS FOR AIR HEATING AND COOLING EnERgy EFFICIEnT SoLUTIonS
www.spcoils.co.uk CoIL HEAT EXCHAngERS FOR AIR HEATING AND COOLING EnERgy EFFICIEnT SoLUTIonS AboUT SPC About SPC The Company S & P Coil Products Limited is a UK based specialist manufacturer and supplier
More informationDehumidification: Energy Efficiency Comparisons
Fourth Annual Energy Management Workshop Cocoa, Florida February 10-11, 2003 Dehumidification: Energy Efficiency Comparisons Michael K. West, Ph.D., P.E. Building Systems Scientist Advantek Consulting,
More informationAir to Water Heat Pump Utilising Natural Refrigerant C02
Air to Water Heat Pump Utilising Natural Refrigerant C02 1 Contents 1. Product Outline 2. General Features Q-ton Dimensions 3. Product Efficiency Comparisons 4. Commercial Applications 5. Beneficial Applications
More informationMechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation
Mechanical Technical Report 1 Standard 62.1 Ventilation Compliance Evaluation Lutheran Theological Seminary at Philadelphia The New Learning Center Prepared For: William P. Bahnfleth, Ph.D., P.E. Department
More informationDOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR
MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR KITCHENS HOTEL CORRIDORS LABORATORIES CONFERENCE CENTERS SCHOOLS PAINT BOOTHS MALLS/SHOPPING CENTERS DOAS UNITS Capacities 5-30 Tons 50-800 MBH 30-120 kw 650-9,000
More informationA Comparison Between Refrigerants Used In Air Conditioning
A Comparison Between Refrigerants Used In Air Conditioning Derya Özkan, Özden Agra and Özlem Çetin University of Yildiz Technical University, Turkey Corresponding email: tumer@yildiz.edu.tr SUMMARY It
More informationHeat Pump Water Heaters
Published on Business Energy Advisor (https://snopud.bizenergyadvisor.com) Home > Heat Pump Water Heaters Heat Pump Water Heaters Heat pump water heater (HPWH) systems extract energy content from a heat
More informationNUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A
NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A [1] Ranendra Roy, [2] Madhu Sruthi Emani, [3] Bijan Kumar Mandal [1], [2],[3] Department of Mechanical
More informationFACT SHEET 9 Large Air-Conditioning (air-to-air)
FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April
More informationSpace Air Diffusion II
MEBS6008 Environmental Services II http://me.hku.hk/bse/mebs6008/ Space Air Diffusion II Ir. Dr. Sam C. M. Hui Visiting Assistant Professor Department of Mechanical Engineering The University of Hong Kong
More informationAmerican.
American 2018 www.vtsgroup.com 01 VTS Group 02 Designer support 1.1 VTS Group... 05 1.2 The 3 Elements of Success... 08 2.1 ClimaCAD Online 4.0 (CCOL 4)... 12 2.2 VTS BIM... 14 03 Units 04 Technical Parameters
More informationrecooler HP EQKR HEAT PUMP
AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.
More informationCHAPTER 1 INTRODUCTION
1 CHAPTER 1 INTRODUCTION 1.1 Background The science which deals with creating a controlled climate in indoor space is called air conditioning. Earlier days the air-conditioning was treated as a luxury,
More informationNumerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger
International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment
More informationOptimisation of cooling coil performance during operation stage for improved humidity control
Indoor Air 2008, 17-22 August 2008, Copenhagen, Denmark - Paper ID: 741 Optimisation of cooling coil performance during operation stage for improved humidity control S.C. Sekhar * and L.T. Tan National
More informationRefrigeration Technology in Building Services Engineering
Unit 70: Unit code: T/600/0459 QCF Level: 3 Credit value: 10 Guided learning hours: 60 Unit aim Refrigeration Technology in Building Services Engineering This unit develops an understanding of the principles,
More informationWORKSHOP VENTILATION- PSYCHROMETRICS-AHU
Alkis Triantafyllopoulos Mechanical Engineer Member TEE, MASHRAE a.trianta@gmail.com WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Based on ASHRAE 62 Purpose Set minimum Outdoor Air ventilation Rates Air Quality
More informationME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3
ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes
More informationAIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION
Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available
More informationRefrigeration Cycle Demonstration Unit R633
Refrigeration Cycle Demonstration Unit R633 Figure 1: R633 Unit Ozone friendly, low pressure, non-toxic working fluid allows evaporation and condensation to be seen in glass cylinders. A Bench top unit
More informationCold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Cold Energy Saver Thermal Mass Cycling Refrigerated Air Dryers (200-1000
More informationTable of Contents. List of Figures and Tables. Executive Summary: 3 ASHRAE Standard 62.1 Section 6 Analysis 7
Army Reserve Center Newport, Rhode Island Technical Report One: ASHRAE Standard 62.1 Ventilat tion and Standard 90.1 Energy Design Evaluations October 4, 2010 2 Table of Contents Executive Summary: 3 ASHRAE
More informationFAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney
FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1
More informationCommercial Refrigeration
Commercial Refrigeration A science of vague assumptions based upon debatable figures taken from inconclusive experiments performed with instruments of problematical accuracy by persons of doubtful reliability
More informationMECHANICAL DESIGN. Full service Mechanical Design Professionals that can provide the full package!
MECHANICAL DESIGN Full service Mechanical Design Professionals that can provide the full package! We specialize in commercial and industrial mechanical system designs that are integral to the building
More informationIndustry co-operation on Natural Refrigerant technology development Kenji Matsuda
Industry co-operation on Natural Refrigerant technology development 2014.02.04 Kenji Matsuda Copyright 2014 JRAIA About JRAIA History The Japan Refrigeration and Air Conditioning Industry Association (JRAIA)
More informationRecommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS
COMMERCIAL REFRIGERATION RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS www.tecumseh.com Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) 1-HCFCs & HFCs Retrofit
More informationMechanical System Redesign. Dedicated Outdoor Air System. Design Criteria
Mechanical System Redesign Dedicated Outdoor Air System Design Criteria The outdoor air conditions used were for Philadelphia, Pennsylvania IAP at a 0.4% occurrence. The supply air conditions were developed
More informationClean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations
Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations Trailer Refrigeration Multi Temperature Truck Refrigeration Single and Multi Temperature Lowest environmental impact
More informationDES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling
DES CHAMPS PRODUCTS Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling DES CHAMPS PRODUCTS Packaged Heat Recovery Systems Micro-Z
More informationRoofPak Applied Rooftop Systems
RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution
More informationSWIMMING POOL SWIMMING POOL DEHUMIDIFICATION
SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL Dehumidification systems for private indoor swimming pools, Dehumidification for swimming pools, hotels, spas or therapeutic clinics spas and therapeutic clinics
More informationLiquid Desiccant Air Conditioning Systems
Liquid Desiccant Air Conditioning Systems High-Efficiency Industrial Dehumidification High-Efficiency External Air Dehumidification Energy-Efficient Heat Pump Drying For Industries Use Only www.ascsciences.com
More informationDESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background
DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS By Yuguo Li and SARS Busters * Background The hospital care workers (HCWs) have been the most severely affected professions during the SARS epidemics in
More informationEnergy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE
This article was published in ASHRAE Journal, March 20145 Copyright 2015 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission
More information2. CURRICULUM. Sl. No.
. CURRICULUM Sl. No. Code Title No. of Lecture Hours 1 RAC 001 Fundamentals of Refrigeration and Air 60 conditioning RAC 00 Psychrometry, Heat load Estimation for 70 Air conditioning and Refrigeration
More informationDERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E
DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units
More informationPERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS
Int. J. Chem. Sci.: 14(S2), 2016, 665-674 ISSN 0972-768X www.sadgurupublications.com PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS J. THAVAMANI *, MARRIPUDAGALA KOMALI, SHAIK
More informationME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY
ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes
More informationInsulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Second Issue April See rear cover for applicable countries
Insulation Second Issue April 2015 See rear cover for applicable countries The Kingspan AN INTRODUCTION TM System Low Energy Low Carbon Buildings Introduction Overview The heating, ventilation and air
More informationcompact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw
w w w. p r o f r o i d. c o m compact TRANSCRITICAL CO 2 BOOSTER RACK Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw compact Refrigeration Rack Transcritical CO 2 booster
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationGo Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More informationState of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney
Frenger Radiant chilled beam performance at 3D Model Creation Daylight Analysis Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled
More informationBall State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder
HVAC DISTRIBUTION and DELIVERY SYSTEMS (Part 2) Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1 Contextual Reminder All-air systems Single zone Terminal reheat Multi-zone Dual-duct VAV Combinations
More informationENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY
SUPERIOR IAQ LOW FIRST COST BEST ROI ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY Pinnacle manages 100% of a building s ventilation and indoor humidity load in a single package. Chilled beams have
More informationTranscritical CO2 Bottle Cooler Development
Transcritical CO2 Bottle Cooler Development C. Rohrer Ingersoll Rand Climate Control, 12999 St. Charles Rock Rd. Bridgeton, MO, United States 314 298-4765, clay_rohrer@irco.com ABSTRACT This paper contains
More informationNumerical study of heat pipe application in heat recovery systems
Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com
More informationEfficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden
Efficient energy recovery in AHU DOHA, Qatar 11.04.2010 Timo Schreck Enventus AB, Sweden Main principles for cooling and dehumidification process in AHU 1. With cooling coil and reheater 2. Energy recovery
More informationGo Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More informationH EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative
A U.S. Environmental Protection Agency survey released in 2007 concluded that IT data centers consumed 61 billion kw of electricity at a total cost of $4.5 billion in 2006. As energy costs continue to
More informationUNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationBrazed Plate Heat Exchanger for CO Applications
Brazed Plate Heat Exchanger for CO Applications www.kaori-bphe.com CO 2 (R744) Due to global warming, climate change phenomenon, and rising restriction on the use of high GWP synthetic refrigerant; replacing
More informationLiquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper
Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements White Paper Abstract Cooling represents the third leading use of energy and source of carbon emissions in
More informationD-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)
More informationCooling Only & Heat Pump
Cooling Only & Heat Pump Daikin is renowned for its pioneering approach to product development and the unrivalled quality and versatility of its integrated solutions. From the efficiency of our compressors
More informationEnergy Recovery with Cooling and Heating
Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationPACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:
PACIFIC HVAC Air conditioner Authorized Daikin Split systems & VRV contractor Tel: 201-266-0049 www.pacificairconditioner.com Daikin RZQ24PVJU9 New Central Air conditioner / Heat pump system High Efficiency
More informationIntegrated Heat Pump Water Heater
Integrated Heat Pump Water Heater Applicable for both Kitchen and Bathroom Application Eco-Friendly Renewable Energy Solution to: Sanitary Hot Water ENERGY FROM THE NATURE Blueway Integrated Heat Pump
More informationTechnical Datasheets. Always By Your Side.
Technical Datasheets Content TCS ATEX 2500 Dehumidifier TCS Eco Dry Dehumidifier TCS120 Dehumidifier TCS170kW IDF Heater TCS180 Dehumidifier TCS270 Dehumidifier TCS300 Dehumidifier TCS420 Dehumidifier
More informationPINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION
ENERGY EFFICIENT DEHUMIDIFICATION PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM Provides a very high degree of latent cooling using only a minimal amount of conventional cooling input Substantial energy
More informationH o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard
H o t Wa te r Syste m s Unvented Hot Water Cylinders Ultrasteel Exceeding the Standard STEP UP TO... Ultrasteel... is the new Albion unvented hot water storage system. Based on the company s experience
More informationRecent Developments in Carbon Dioxide Cooling in Data Centres & Buildings. by Rob Lamb, Sales Director, Star Refrigeration
Recent Developments in Carbon Dioxide Cooling in Data Centres & Buildings by Rob Lamb, Sales Director, Star Refrigeration CO2 Case Studies Server Cooling Desk Cooling Heat Pump / Chiller Air Handling Unit
More informationChapter 2. Alternatives to HCFCs and their Characteristics
Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid
More informationMenerga Adconair Various solutions one heat recovery system
Menerga Adconair Various solutions one heat recovery MINIMAL ENERGY APPLICATION MENERGA Menerga has developed and produced innovative ventilation and air conditioning s for extensive fields of application
More information