ProVaxTM EUPOPEAN & AUSTRALIAN OPERATING MANUAL

Size: px
Start display at page:

Download "ProVaxTM EUPOPEAN & AUSTRALIAN OPERATING MANUAL"

Transcription

1 REFRIGERANT RECOVERY/EVACUATION SYSTEM from I N S I D E TM US patents: 4,523,897; 5,209,653, other US and foreign patents pending. ProVaxTM EUPOPEAN & AUSTRALIAN OPERATING MANUAL ADVANCED TEST PRODUCTS, INC. Miramar, FL Telephone: (954) Fax: (866) Toll Free: (800)

2 TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFETY INFORMATION and OPERATING GUIDELINES 3-4 CARE AND MAINTENANCE OF YOUR ProVax TM 5 ADDITIONAL RECOVERY TANK INFORMATION 6 PURGING NON-CONDENSABLE GASES 7 HELPFUL HINTS FOR REFRIGERANT RECOVERY & EVACUATION 8-9 OPERATING YOUR ProVax TM SELF PURGING YOUR ProVax TM 12 PULLING A VACUUM 12 DIAGRAM FOR REFRIGERANT RECOVERY & EVACUATION DIAGRAM FOR "PUSH/PULL" METHOD 13 SET-UP DIAGRAM FOR TANK PRE OR SUB COOLING PROCEDURE 13 OPTIONAL RECOVERY / TANK PRE OR SUB COOLING FOR FIXED 14 HOSE SET-UP VACUUM PUMP MAINTENANCE / OIL CHANGE 15 ProVax PARTS DIAGRAM/PARTS AND ACCESSORIES LIST ProVax WIRING DIAGRAM 18 TROUBLESHOOTING YOUR PROVAX TM SPECIFICATIONS 21 WARRANTY INFORMATION 22 1

3 INTRODUCTION Congratulations on your purchase of the ProVax refrigeration recovery/evacuation system. Using an innovative new design (patents pending), Promax has created a unique recovery system. The ProVax combines both a recovery unit and a vacuum pump into one unit, conveniently eliminating the need to carry both to the job site. A Robinair Cooltech 6 CFM (142 l/min) vacuum pump, using a two-stage, offset rotary vane design, provides a powerful high vacuum capability and assures moisture removal, while its high pumping capacity reduces evacuation time. US patents: 4,523,897; 5,209,653, other US and foreign patents pending. The ProVax provides everything you need to recover and evacuate a system, all in one package. 2

4 IMPORTANT SAFETY & OPERATING GUIDLINE INFORMATION PERSONAL SAFETY SAFETY COMES FIRST! Read all safety, operating guidelines and instructions before operating your ProVax TM. CAUTION: ONLY A QUALIFIED TECHNICIAN SHOULD OPERATE THIS RECOVERY UNIT. The operator must be familiar with air conditioning and refrigeration systems, refrigerants and the dangers of pressurized components. Always think before acting, familiarity breeds carelessness and carelessness can be harmful to your health, or worse, result in death. WARNING: Always wear safety goggles and protective gloves when working with refrigerants. Contact with refrigerant may cause injury. Disconnect hoses with extreme caution! All hoses may contain liquid refrigerant under pressure. Read all safety information regarding the safe handling of refrigerant and refrigerant oil, including the Material Safety Data Sheet. MSDS sheets can be obtained from your refrigerant supplier. Be sure that any room where you are working is thoroughly ventilated, especially if a leak is suspected. Refrigerant vapor is hazardous to your health and can cause death. Avoid breathing A/C refrigerant and lubrication vapor or mist. Exposure may irritate eyes,nose and throat. If accidental system discharge occurs, ventilate work area before resuming service. To reduce the risk of injury, care should be taken when moving this equipment. A scale must be used to avoid overfilling the storage tank. DO NOT OVERFILL. Tank is full at 80% volume. Tank may explode if filled more than 80% due to liquid expansion. Table 1 is a representative sample for R-22 refrigerant: TANK SIZE MAX NET WEIGHT 13.6 Kg. Tank (30 Lb.) 10.9 Kg. (24 Lb.) 22.7 Kg. Tank (50 Lb.) 18 Kg. (40 Lb.) TABLE 1: Representative Sample, R-22 Note: Promax strongly recommends the use of the ADS-100 Refrigerant Scale for monitoring tank capacity. Your ProVax-E has an Internal Pressure Shut- Off switch. If the pressure inside system should rise above 38.5 bars (558psi), the system will automatically shut off. The shut-off switch must be manually reset. Access to the shut-off switch is through the hole located in the lower right of the front panel. WARNING: The Internal Pressure Shut Off Switches do not prevent tank overfill. If your system shuts off on high pressure and is connected to your tank, you may have overfilled your tank and created a very dangerous situation! Take immediate measures to relieve any high pressure and/or tank overfill. When recovering large amounts of liquid, use the "Push/Pull method (see diagram on page 13). CAUTION: When using the "Push/Pull" method, once the "Push/Pull" siphon is started, it can continue and overfill the storage tank even if the tank is equipped with a "shut off" float sensor. The siphon can continue even after the machine is turned off.you must manually close the valves on the tank and the unit to prevent overfilling of the recovery tank. Always operate the unit on a flat level surface. If the tank pressure exceeds 20.7 bar / 2070 kpa (300 psi), use the tank cooling procedure to reduce the tank pressure. (See Pages 13 & 14) 3

5 IMPORTANT SAFETY & OPERATING GUIDLINE INFORMATION CONT- ELECTRICAL SAFETY When using an extension cord it should be a 3-wire, 14 AWG minimum and no longer than 7.62 meters (25 feet). WARNING! Whenever you perform any type of maintenance work on your ProVax, insure that it is disconnected from the power supply before you begin. FIRE SAFETY WARNING: TO REDUCE THE RISKOF FIRE: Never operate unit in an explosive environment! Do not use this equipment in the vicinity of spilled or open containers of gasoline or any other flammable liquid. Use this equipment in locations with mechanical ventilation that provides at least four air changes per hour or locate the equipment at least 0.46 meters (18 inches) above the floor. Never use oxygen when testing for leaks. Any oil in contact with oxygen under pressure will form an explosive mixture. Always open service and cylinder valves slowly. This allows rapid control of the flow of gases if there is any danger. Once it is determined that there is no danger, the valves can be opened fully. Always isolate large amounts of refrigerant and close off valves after use, so if a leak should develop anywhere in the system, the refrigerant will not escape. Keep all connections to the refrigeration system thoroughly dry and clean. If moisture enters the refrigeration system, it is likely to cause considerable damage. WARNING! Pressurized tank contains liquid refrigerant. Never overfill storage tanks. Overfilling of the tank may cause a violent explosion and possible injury or death. Do not exceed the working pressure of Recovery Tank cylinder. REFRIGERANT SAFETY ProVax is approved for use with the following category III, IV and V refrigerants (Per ARI 740): R-12, R-22, R-134A, R-401A, R-401B, R-401C, R-402A, R-402-B, R-404A, R-406A, R-407A, R-407-B, R-407C, R-407D, R-408A, R-409A, R-410A, R-411A, R-411B, R-412A, R-500, R-502, R-507 and R-509 4

6 CARE AND MAINTENANCE OF YOUR ProVax TM Use of a filter/dryer at the inlet is mandatory. A filter/dryer must always be used between the recovery machine and the inlet hose.we recommend that a clean filter be used for every service job. Failure to use a filter will invalidate your warranty. The use of a filter will greatly reduce the risk of damage to your ProVax, by preventing foreign material from entering the unit. Each filter should be labeled and used exclusively for one type of refrigerant only. Special care should be taken when recovering from a "burned-out" system. Use two high acid capacity filters, in series. (Alco type EK-162-F or Sporlan type C-162-F are recommended )When you have finished recovering from the system, flush your ProVax with a small amount of clean refrigerant and refrigerant oil to purge off any foreign substances left in the unit. Do not expose Vacuum Pump to pressure. It is protected by a pressure cut-off switch set at 1.72 bar / 172 kpa (25 psi) (+/- 5). Maximum vacuum level of.44 bar / 44 kpa (13 in. Hg) (+/- 3) while in Recovery mode. The compressor is protected by a low pressure cut-out switch set at.44 bar / 44 kpa (13 in. Hg) (+/- 3). Use Vacuum mode to fully evacuate system. Always empty refrigerant from the ProVax into a storage tank; see Self-Purge procedure on Page 12. Liquid refrigerant left in the ProVax s condenser may expand, causing damage to components. If the unit is to be stored or not used for any length of time, we recommend that it be complenty evacuated of any residual refrigerant and purged with dry nitrogen. 5

7 ADDITIONAL RECOVERY TANK INFORMATION WARNING: Also read the information pertaining to recovery tanks, previously listed under Safety Information and Operating Guidelines. CAUTION: NEVER use a standard disposable 13.6 Kg (30Lb) (the type of container in which virgin refrigerant is sold) to recover refrigerant. Use ONLY authorized refillable refrigerant tanks that meet government transportation requirements. WARNING: DO NOT: Exceed the working pressure of each cylinder. Recovery cylinders are designed for different pressures. Your ProVax is not supplied with a recovery tank, it requires the use of tanks with a minimum of 24.1 BAR (350psi) working pressure and Promax strongly recommends the use of 27.6 bar / 2760 kpa (400 psi) tanks NOTE: The use of a 27.6 bar / 2760 kpa (400 psi) tank is mandatory when recovering R-410A. See Promax Recovery Tanks under Parts and Accessories section on Page 17. Tanks and filters should be designated for one refrigerant only. Before using a tank previously used for another refrigerant, completely empty the tank, evacuate it and purge the tank using dry nitrogen, and then re-evacuate it. Always store refrigerant containers in a cool dry place. Do not mix refrigerants in a system, a tank or any where else. Each type of refrigerant must have its own tank, filter, etc. Storage cylinders sometimes have valves that are not properly seated when manufactured. Keeping caps on these valves will guard against refrigerant leakage. Safety codes recommend that closed tanks not be filled over 80% of volume with liquid. The remaining 20% is called head pressure room. WARNING! NEVER TRANSPORT AN OVERFILLED CYLINDER Refrigerant expands when it gets warm and may cause a tank to explode if overfilled. CYLINDER TEMPERATURE 15.6 C 21.1 C 37.8 C 54.4 C 65.6 C STARTING WITH CYLINDER 80% BY VOLUME SPACE OCCUPIED BY LIQUID 80% 81% 83% 90% 94% STARTING WITH CYLINDER 90% BY VOLUME SPACE OCCUPIED BY LIQUID 90% 92% 96% 100% 6

8 PURGING NON-CONDENSABLE GASES FROM REFRIGERANT TANK 1. Allow the tank to sit undisturbed for 24 hours. This allows the air to rise to the top. 2. Connect a manifold to the tank and read the amount of pressure in the tank by looking at the output pressure gauge. 3. Determine the ambient temperature in the room. 4. Refer to a Refrigerant pressure/temperature chart. Find the temperature on the chart and look across to the corresponding pressure for the type of refrigerant in the tank. Determine how that relates to the reading on the gauge. 5. If the pressure reading is higher than the pressure shown on the chart, very slowly (so as not to cause turbulence inside the tank) crack open the vapor port valve. Watch the pressure on the gauge decrease. To prevent venting, add.27 to.34 bar / 27 to 34 kpa (4-5 psi) to the pressure shown on the to the pressure shown on the chart. When the gauge corresponds to that pressure, close the vapor port valve. 6. Allow the tank to sit for 10 minutes and check the pressure again. 7.Repeat the process again if necessary. 7

9 HELPFUL HINTS FOR REFRIGERANT RECOVERY Refrigerant recovery has come a long way in a few short years. On the surface it's simply the process of taking refrigerant out of a system and putting it into a tank. However, this simple process can quickly become problematic if a few items are overlooked. The following are some tips and pointers we've accumulated over the last few years that can save you time and make the process go smoother. First you need to identify the refrigerant type and quantity in the system you are servicing. If you determine it s a burnout, you need a special tank (a tank that's identified as containing burnout or other unidentified gases), and you need to use extra filtration prior to recovery. (See special care note on page 5). If, on the other hand, you know the gas in the system is relatively clean or new, then a new tank should be used. If you're planning on putting the refrigerant back into the same system after you have finished the service or if the refrigerant is going to be reclaimed, then use a tank that has the same refrigerant in it. A word of caution about Environmental Protection Agencies; If you use a variety of refrigerant gasses in your service work - as evidenced by your refrigerant purchases - and you only own one tank, you are asking for trouble. You would be well advised to own at least one tank for every refrigerant type serviced, plus an extra for burnouts and other unknowns. PLANNING AHEAD Knowing the quantity of refrigerant is important for planning storage requirements, as well as planning for the actual recovery. For instance, any system with more than 5lbs. of refrigerant is likely to have areas where the liquid can get trapped. The key to a quick recovery procedure is to get the liquid out first, and then get the remaining vapor out. However most systems are not "recovery friendly." That is they don't have access ports at their lowest points. If some units you're servicing are on maintenance contracts, you would save significant time by installing access ports at all of the lowest points in the system, where liquid is likely to accumulate. Since most systems don't have these ports you need to be prepared to boil off the trapped liquid with a heat gun, when ever it's found. An indicator of trapped liquid in a system is frost or condensation forming on the plumbing or components where the liquid is trapped. The trapped liquid may be in an area that is not visible. In all cases trapped liquid in a system during recovery causes the recovery process to slow down, regardless of the size or type of machine (see diagram). If you are unable to locate the trapped liquid, but you know it's there, because the recovery job is taking "forever". Turn on the system compressor (if it's operable) for a few seconds, this will get the refrigerant moving to another part of the system and in the process pick up enough heat to boil off. Pstart Pe Results of Liquid Refrigerant Trapped in a System Forever 0 10 Hg Tstart Time Tfinish HOSES AND VALVES Hoses and Schraeder valves have a large impact on recovery speed. In general, the larger the hose, the less friction on the flow of refrigerant, the quicker the recovery time. Many contractors are now using 9.5mm (3/8') lines for the input to the recovery machine, even those lines originating out of 6.3mm(1/4") fittings, and the shortest hose possible. Schraeder valves must be removed from the connection prior to an expedient recovery. Most wholesalers sell a tool for removing these cores, while keeping the connection sealed. The core depressor, in the end of the hose, should also be removed. These two items can turn a 20 minute job into one that goes on for hours. So, be sure to remove the Schraeder valves and core depressors before every recovery job. Another hose consideration is the little rubber grommet at the end of the hose that makes a seal with the flare fitting. We've seen these seals so worn and deformed that when the hose is connected to the flare fitting the grommet virtually seals off the connection. 8

10 HELPFUL HINTS FOR REFRIGERANT RECOVERY - cont. This is probably never noticed in charging, because the pressure opens the grommet, but during recovery (or with suction) the deformed grommet severely restricts the flow of refrigerant. REFRIGERANT RECYCLING Current regulations state that used refrigerant shall not be sold, or used in a different owner's equipment, unless the refrigerant has been laboratory analyzed and found to meet the requirements of ARI 700 (latest edition). As a result, recycling and verifying ARI 700 conformance isn't economically justified in most cases. It's still a great idea to do as much cleaning of refrigerant going back into the same system (or owners system) as possible. We recommend using the largest, high-acid capacity filter, that are economically feasible. Put these filters on the suction or inlet side of the recovery unit. Change filters often. The recovery of large amounts of liquid refrigerant can sometimes carry with it large quantities of oil, if the system being serviced doesn't have an adequate oil separator installed. If this recovered refrigerant isn't going to be liquid charged back into the same system, you might want to separate the refrigerant from the oil in order to measure the oil (to know how much oil to charge back into the system). Refrigerant sent back for reclaim does not need to have the oil removed. One of the simplest and most cost effective ways to achieve this is to use a 13.6kg or 22.7kg (30 or 50 lb.) tank in line with your recovery machine. Connect the system to the liquid port of the tank, then from the vapor port of the tank connect to the input of your recovery machine. A second tank, for storing refrigerant, should then be connected to the output of the recovery machine. If you encounter large amounts of liquid you will need to put a band heater around the first tank. When the recovery job is complete the oil can be removed, from the first tank, by applying a small amount of pressure, using nitrogen, to one of the ports and extracting the oil from the other. If you are going to remove the oil from the vapor port you will need to turn the tank upside down. Always wear safety glasses when performing this operation as the oil may be acidic and could cause severe burning. KEEPING THE DIRT OUT During the recovery process your recovery machine can be exposed to debris that can, potentially, damage it. This includes brazing spatter and copper/ brass slithers. Further contamination can be introduced from the refrigerant storage tanks. To prolong the life of your recovery machine, always use an inline filter at the inlet Port. Whenever you are charging a system from a recovery cylinder it is a good idea to use an in-line filter to protect the system from contamination. Again, change your in-line filters often. GETTING THE LIQUID OUT See diagram on page 13 of this manual Push/pull is a method of removing bulk liquid from a system using the pressure differential created by the recovery machine. Push-pull will generally not work on smaller systems because there is no bulk liquid reservoir to create a siphon from. Push-pull is mostly used on systems with a receiver tank or those with greater than 9.1kg (20 lbs.) of refrigerant, or when transferring from one tank to another. The rate of liquid transfer is very much dependent on hose size, with larger hoses providing much better throughput. Another trick is to cool the tank, if it's partially filled, prior to or during recovery. This operation will lower the pressure in the storage tank and therefore speed up recovery. There must be a minimum of 2.3kg (5 lbs) of liquid refrigerant in the tank you wish to chill. This operation can be performed prior to or during the recovery. See the two set up diagrams and procedures on pages of this manual. There is nothing magic here, you are simply using your recovery machine to make a refrigerator where the tank is the evaporator. By throttling the output valve, you're effectively creating a capillary tube or an expansion device, but you need to adjust the back pressure to suit the conditions and the refrigerant. Five to ten minutes of chilling can produce some very dramatic tank cooling, depending on the conditions. If there are any non condensables in the tank this process will not work. The greater the quantity of refrigerant in the tank the longer the process will take. 9

11 OPERATING YOUR ProVax TM ProVax TM Control Panel Overview Inlet Pressure Gauge* Outlet Pressure Gauge Powers Unit & Turns on Cooling Fans Recovery/Purge Selector Starts Compressor/Vacuum Pump Recovery Inlet Port and Liquid/Vapor Adjustment Recovery/Evacuation Inlet Port Recovery/Evacuate Mode Selector Recovery Outlet Port Over Pressure Reset Recovery Outlet Port Note: *Promax recommends the use of the Robinair Electronic Thermistor Vacuum Gauge to monitor vacuum level 10

12 OPERATING YOUR ProVax TM 1. Inspect the ProVax thoroughly to insure that it is in good operating condition. PROCEDURE FOR NORMAL SYSTEM RECOVERY 9. Open the output valve/knob (RED) on the ProVax. 2. Ensure that the outlet valve/knob (RED) and the inlet valve/knob (BLUE) on the ProVax are in the closed positions. 3. Set the "Mode" valve/knob (Yellow) to Recovery 4. Set the "Recover/Purge" valve/knob (BLACK) to "Recover". 5. Connect ProVax to the system being serviced, making sure all connections are correct and tight. (see set-up diagram). 6. Open the liquid port of the recovery cylinder (always open valves slowly to check hoses and connections for leaks). 7. Open the liquid port on your manifold gauge set. Opening the liquid port will remove the liquid from the system first, greatly reducing the recovery time. (after the liquid has been removed, open the manifold vapor port to finish evacuating the system). Note: The ProVax uses an "oil-less" compressor during recovery. It is lubricated with the oil suspended in the refrigerant. Ensure there is refrigerant up to the ProVax inlet valve prior to turning on the unit. 8. Connect your ProVax to Power. a. Turn on the "Power" switch. You should hear the cooling fans running b. Press the "Start" switch. This momentary switch will start the compressor/motor. 10. Slowly open the input valve/knob (BLUE) on the ProVax. a. If the compressor starts to knock, slowly throttle back the input valve/knob until the knocking stops. b. If the input valve was throttled back, it should be fully opened once the liquid has been removed from the system (the manifold gauge set vapor port should also be opened at this time). 11. The ProVax will automatically stop after the refrigerant has been removed and it reaches.34 to.68 bar / 34 to 68 kpa (10 to 20" hg) vacuum. Note: Anytime you want to pause an operation, you can stop the unit by turning the "MODE" valve/knob (YELLOW) to Stop. Note: To restart, turn the Recover/Purge valve/knob (BLACK) to Recover and the input valve/knob (BLUE) to Closed and press the Start switch. 12. Close the manifold gauge set s vapor and liquid ports. 13. Turn the ProVax input valve/knob (BLUE) to the Closed position. 14. Proceed with the Self Purge and Vacuum. (see Self Purge/Vacuum procedure on page 12). Note: Always purge the ProVax after each use. Failure to purge the remaining refrigerant from the ProVax could result in the acidic degradation of internal components, ultimately causing premature failure of the unit. 11

13 OPERATING YOUR Provax - cont. PROCEDURE FOR SELF PURGE 1. Ensure the "MODE" valve/knob (YELLOW) is in the "Recovery" position. 2. Ensure the Recover/Purge valve/knob (BLACK) is the Recover position. Note: will be moved to Purge position after start. 3. Turn the input valve/knob (BLUE) to Purge 4. Restart the ProVax. a. Power "On" b. Press "Start" 5. Turn the Recover/Purge valve/knob (BLACK) to the "Purge" position. 6. Open the Output valve/knob (RED) 7. The ProVax will automaticaly stop after the unit is purged and it reaches 10 to 20 hg vacuum. 8. Close the recovery tank valves and close the Outlet valve/knob (RED) and Inlet valve/knob (BLUE) on the ProVax. 9. Turn the ProVax Power switch "Off". 10. Return the Recover/Purge valve/knob (BLACK) knob to the "Recover" position. 11. Turn the Inlet valve/knob (BLUE) to the "Closed" position. 12. Disconnect and store all hoses. Note: It is recommended that the in-line filter/dryer be replaced after every recovery job. PROCEDURE FOR PULLING A VACUUM WARNING: Do not expose the inlet-port of the ProVax to pressure while in the Vacuum Mode 1. Turn BLUE valve/knob to "Closed" position 2. Turn Recover/Purgevalve/knob (BLACK) to Recover 3. Turn output valve/knob (RED) to "Closed" 4. Turn "MODE" valve/knob (YELLOW) to "Vacuum" position 5. Start unit. a. Power "On" b. Press "Start" 6. Run until desired vacuum is reached 7. To stop, rotate "MODE" valve/knob (YELLOW) to the "Stop" position. 8. Cap inlet port to prevent contamination. DIAGRAM FOR REFRIGERATION RECOVERY THIS IS THE FASTEST METHOD FOR RECOVERING VAPOR REFRIGERANT OPTIONAL MOISTURE SIGHT GLASS MANIFOLD GAUGE INPUT SET SYSTEM BEING SERVICED OUTPUT LIQUID VAPOR LIQUID WARNING! SCALE MUST BE USED TO AVOID OVER FILLING THE STORAGE TANK 12

14 DIAGRAM FOR PUSH/PULL METHOD Push/pull method only works with large systems where the liquid is readily accessible. Do not use this method on systems that contain less than 6.8 kg (15 lbs.) as it may not work. The sight glass is used to provide a method of determining the moisture content and quality of a system s refrigerant. CAUTION: When using the Push/Pull method, once the siphon is started, it can continue and overfill the storage tank even if the tank is equipped with a float level sensor. The siphon can continue even when the machine is turned off. You must manually close the valves on the tank and the unit to prevent overfilling of the recovery tank. 1. Close INPUT and OUTPUT valves 2. Turn MODE knob to "RECOVERY" 3. Turn RECOVERY/PURGE knob to "RECOVER" 4. Start machine 5. Open INPUT valve to the "VAPOR" position and OUTPUT valve to "OPEN" 6. When the refrigerant scale stops rising, close all ports CAUTION: Do not overfill tank 7. Turn MODE knob to "STOP" 8. Switch off machine SYSTEM BEING SERVICED LIQUID INPUT VAPOR OPTIONAL MOISTURE SIGHT GLASS OUTPUT LIQUID Warning! A scale must be used to avoid over filling the storage tank. SET-UP DIAGRAM FOR TANK PRE OR SUB COOLING PROCEDURE See page 9 for more information on Sub Cooling. VAPOR INPUT OUTPUT LIQUID Note: To begin this process you must have a minimum of 2.3 Kg (5 lbs). of liquid refrigerant in the tank. If this is not the case, using a fully evacuated empty tank will help you achieve the fastest recovery time. 1. Close INPUT and OUTPUT valves 2. Turn MODE knob to "RECOVERY" 3. Turn RECOVERY/PURGE knob to "RECOVER" 4. Start machine 5. Open INPUT valve to the "LIQUID" position 6. Throttle the OUTPUT valve so that the output pressure is 6.9 bar / 690 kpa (100 psi) greater than the input pressure, but never more than 20.7 bar / 2070 kpa (300 psi) 7. Run until tank is cold 13

15 OPTIONAL RECOVERY/TANK PRE OR SUB COOLING FOR FIXED HOSE SET-UP MANIFOLD GAUGE SET INPUT SYSTEM BEING SERVICED LIQUID VAPOR LIQUID OUTPUT WARNING! A scale must be used to avoid over filling the storage tank. NORMAL RECOVERY: Tank Vapor valve is closed TANK PRE OR SUB COOLING: Tank Vapor valve is open and both manifold gauge set valves are closed. 14

16 VACUUM PUMP MAINTENANCE Vacuum Pump Oil For maximum performance, Promax recommends changing vacuum pump oil after each use. The condition and type of oil used in any high vacuum pump are extremely important in determining the ultimate attainable vacuum. Promax recommends the use of Robinairs Premium High Vacuum Pump Oil. This oil has been specifically blended to maintain maximum viscosity at normal running temperatures and to improve cold weather starts. Robinair Premium High Vacuum Pump Oil is available in handy quart containers or in convenient gallon containers. Order by part number: Pint (shipped 12 pints per case) Quart (shipped 12 quarts per case) Gallon (shipped 4 gallons per case) VACUUM PUMP OIL CHANGE PROCEDURE 1. Warm up the vacuum pump by running: a. Place a cap on the inlet port b. Turn Mode knob (Yellow) to "Vacuum" c. Turn on "Power" switch d. Press "Start" switch e. Run for 2 minutes and then turn off power. OIL OIL FILLER CAP CAP Note: ProVax inlet gauge does not indicate vacuum level. Use a separate vacuum gauge to observe vacuum level. OIL DRAIN OIL CAP 2. Unplug unit from power source 3. Place ProVax on a raised surface, with oil drain plug on the bottom of the unit exposed 4. Place a suitable container under drain plug 5. Remove OIL FILL cap 6. Remove OIL DRAIN cap 7. Drain oil into container until flow of oil has completely stopped 8. Replace the OIL DRAIN cap 9. Fill oil reservoir with new vacuum pump oil until oil just shows at of bottom of the sight glass. The approximate oil capacity is 15 ounces (444 ml). 10. Be sure the inlet port is capped and TURN ON vacuum pump (see step 1) 11. Allow pump to run for one minute, then check the oil level. If the oil is below the sight glass OIL FILL line, add oil slowly (while pump is running) until the oil reaches the OIL LEVEL line. 12. Replace the OIL FILL cap, making sure the inlet is capped and the drain cap is tight. 15

17 ProVax TM PARTS DIAGRAM Front (Section 1) Back (Section 4) 11 Control Panel (Section 2) Motor/Compressor/Pump (Section 3) (Note: For compressor Repair Kits see page 17) Section 1 - ProVax Front: Item.# Part# Description (14) Front & Rear Case, plastic (set) (15) Filter Drier (16) " Blue Hose (17) Rubber Foot Section 2 - Provax Control Panel: Item.# Part# Description (11) Front Panel (12) GA1500 Pressure Gauge, 345 bar (500 psi) (13) GA0800 Pressure Gauge, 55.1 bar (800 psi) *(12) ATP Pressure Gauge, 3450 kpa (500 psi) *(13) ATP Pressure Gauge, 5510 kpa (800 psi) N/S GA1000 Gauge Lens N/S Inlet & outlet Fitting 45 degree N/S NB6501 Inlet & outlet Fitting Protection Cap N/S EL1309 Start Switch, momentary N/S EL1310 ON-OFF Switch N/S ASM Manifold Assembly N/S Vacuum Switch (13in Hg) N/S Vacuum Protection Switch N/S Black Knob N/S Blue Knob N/S Red Knob N/S Yellow Knob N/S High Pressure Cut off Switch Section 3 - ProVax Motor/Compressor/Vacuum Pump: Item.# Part# Description (8) ASM Compressor Assembly (9) Motor, V 50/60Hz (10) ASM Vacuum Pump Assembly N/S ASM Vacuum Pump Clutch Assy N/S ASM Compressor Clutch Assy. N/S Vacuum Pump & Motor "Vibration" Mount Section 4 - ProVax Back: Item.# Part# Description (1) Front & Rear Case, plastic (set) (2) Condenser (3) Handle (4) Wheel N/S Retaining ring, wheel N/S Axle, wheel (5) EL1818EL1817 Axial Fan, 220V (6) Oil Filler Cap N/S NB6501 Oil Drain Cap N/S EL1500 Relay N/S Compressor Grill N/S Vacuum Pump Grill N/S Fan Grill N/S Bumper *Used on ProVax-A Australian Version 16

18 REPLACEMENT KITS PART# DESCRIPTION PREMIUM HIGH VACUUM PUMP OIL, PINT BOTTLE (case of 12) VACUUM PUMP SEAL REPLACEMENT KIT KT3302 KT3303 KT3307 KT3308 PISTON SEAL REPLACEMENT (middle section of compressor) VALVE REPLACEMENT KIT (top section of compressor) COMPRESSOR REPAIR KIT (all three sections of compressor) SHAFT REPLACEMENT KIT (bottom section of compressor) RECOMMENDED ACCESSORIES PART# DESCRIPTION RGT KG (30 LB) RECOVERY TANK, 24.1 BAR / 2410 kpa (350 psi) working pressure with capacity sensor RGT30NS SAME AS RGT30, WITHOUT SENSOR RGT KG (50 LB) RECOVERY TANK, 24.1 bar /240 kpa (350 psi) working pressure with capacity sensor RGT50NS SAME AS RGT50, WITHOUT SENSOR RGT50HP 50 LB RECOVERY TANK, HIGH PRESSURE, 27.6 bar / 2760 PA (400 psi) working pressure with capacity sensor HEATER BLANKET ADS-100 REFRIGERANT SCALE, 90KG (200 LB) CAPACITY, WITH REMOVABLE PLATFORM HIGH PRESSURE MANIFOLD SET, 60 COLOR CODED HOSES, FOR R410A TWO WAY MANIFOLD SET, 72 COLOR CODED HOSES, FOR R22 AND R134a ELECTRONIC THERMISTOR VACUUM GAUGE REFRIGERANT IDENTIFIER 4650 MIRROR AND MAGNET SET TIFZX-1E HEATED PENTODE TM REFRIGERANT LEAK DETECTOR NOTE: For details see: 17

19 ProVax TM WIRING DIAGRAM R RECEPTACLE GRN GRN BLK VAC PROTECT SW EL1310 POWER SWITCH BLK BLK BRN BRN EL1818 FAN EL1818 FAN BLK BRN BRN BLK GRN ORG BLK PRESSURE SWITCH BLK BLU EL1309 START SWITCH ORANGE RED BLK BLUE MOTOR RED BLK (2X) SWITCH BANK LEFT LOW PRES. SW BLK RED (2X) SWITCH BANK RIGHT BLK EL PIN CONNECTOR FOR UPGRADE 3 0 (NEUTRAL) RELAY START TH1 MAIN Thermal Protector CENTRIFUGAL SWITCH JUMPER (REMOVE WHEN USING UPGRADE FEATURE) GRN BLK MOUNT STUD 18

20 TROUBLESHOOTING YOUR ProVax SAFETY FIRST Read and understand all safety information contained in this manual before servicing the unit. CONNECT UNIT TO 230V FAN IS RUNNING WHEN POWER SWITCH IS IN ON POSITION YES COMPRESSOR STARTS WHEN START SWITCH IS PRESSED YES UNIT PUMPS INTO HIGH PRESSURE SHUT OFF YES NO NO NO CHECK POWER SUPPLY YES DO YOU HAVE 230V SUPPLY? YES ARE VALVES OPEN? CHECK FOR SCHRADER VALVES YES NO NO NO DO YOU HAVE 230V SUPPLY? NO PROVIDE 230V OPEN VALVES CALL YOUR LOCAL PROMAX DISTRIBUTOR UNIT PULLS INTO A VACUUM NO ARE YOUR HOSES TIGHT? DO YOU HAVE LEAKS? NO DOES UNIT PULL A VACUUM WHEN INPUT VALVE IS CLOSED? NO YES YES YES TROUBLESHOOTING ENDS 19

21 TROUBLESHOOTING GUIDE Vacuum Pump Your CoolTech pump has been designed for dependable use and long life. If something should go wrong, however, the following guide will help you get the pump back in service as quickly as possible. If disassembly of the pump is required, please check your warranty. The warranty may be voided by misuse or customer tampering, which results in the pump being inoperable. Oil Leakage Failure To Pull A Good Vacuum 1.Be sure the oil is not a residual accumulation from spillage, etc. 2. If leakage exists, the module cover gasket or the shaft seal may need replacing. Follow the instructions supplied with the Seal Replacement Kit, part number If leakage exists in the area of the oil drain plug, you may need to reseal the plug using a commercial pipe thread sealer. 1. Be sure the vacuum gauge and all connections are in good condition and leak-free. You can confirm leakage by monitoring the vacuum with a thermistor gauge while applying vacuum pump oil at connections or suspected leak points. The vacuum will improve briefly while the oil is sealing the leak. 2. Be sure the pump oil is clean. A badly contaminated pump may require several oil flushes. See OIL CHANGE PROCEDURE. Note: Use only high vacuum pump oil such as Robinairs Premium High Vacuum Pump Oil. Other oils will prevent pull-down to a deep vacuum. 3. Be sure the oil is at the proper level. For maximum pump operation, the oil must be even with the OIL LEVEL line on the sight glass when the pump is running. See OIL CHANGE PROCEDURE. Do not overfill operating temperatures will cause the oil to expand so it will appear at a higher level than when the pump is not running. To check the oil level, start the pump with the inlet capped. Check the oil level in the sight glass. Add oil if necessary. 20

22 SPECIFICATIONS Recovery Section Vacuum Section Refrigerants Cat. III: R-12, R-134a, R-401C, R-406A, R-500, same Cat. IV: R-22, R-401A, R-401B, 402B, R-407C, R-407D, R-408A, R-409A, R-411A, R-411B, R-412A, R-502, R-509, Cat. V: R-402A, R-404A, R-407A, R-407B, R-410A, R-507 Input Voltage Vac 50/60 Hz same Motor 1/2 HP, AC, inductive run, brushless Motor Speed 1425 RPM (50 Hz) 1725 RPM (60 Hz) same Current Draw Full Load: VAC; Locked Rotor: 18 amps n/a Compressor Type Proprietary "Oil-less," air cooled, piston style, Kynar TM poppet valves, triple teflon TM ceramic polymer piston seals n/a High Pressure Shut-off 38.5 bar / 3850 kpa (558 psi) n/a Recovery low pressure 0.44 bar / 44 kpa / (13 in Hg) ( + /-3) Cut-Out Switch Refrigerant Class Refrigerant Recovery Category III Category IV Category V Rate: Push/Pull Refrigerant Recovery Rate: Liquid 8.00 Lbs./min Lbs./min Lbs./min kg/min 4.32 kg/min 4.91 kg/min Lbs./min Lbs./min Lbs./min kg/min kg/min kg/min. n/a n/a n/a Refrigerant Recovery Rate: Vapor 1 Lbs./min. 1,12 Lbs./min. 1,22 Lbs./min kg/min. 0.5 kg/min kg/min. n/a Vacuum Pump Type n/a Offset Rotary Vane Stages n/a 2 Stage Free Air Displacement n/a 6 CFM (142 l/min.) Factory Micron Rating n/a 20 microns Approx. Oil Capacity n/a 15 oz. (444 ml) Maximum Vacuum Pump 1.72 bar / 172 kpm Protection Cut-off Switch n/a (25psi) (+ / - 5) Operating Temp. 0ºC to 68.3 C (32 F to 155 F) same Dimensions 63.5cm H x 55.8cm W x 25.4cm D (25" H X 22" W X 10" D) n/a Weight 24,5 Kg (54 lbs) n/a EPA Certification ARI-740 by UL (control no.8ea7) n/a 21

23 MFG # Promax products are warranted to be free from defects in workmanship and materials for a period of one year from date of purchase. THE FOLLOWING RESTRICTIONS APPLY: 1. The warranty applies to products in normal use only, as described in the operating manual. The product must also be serviced and maintained as described therein. 2. If the product fails, it will be replaced at the option of Advanced Test Products, Inc. (ATP) 3. Warranty service claims are subject to factory inspection for product defect(s). If during the warranty evaluation it is determined that a filter has not been used or that the filter was not properly maintained or that the machine has been used in any way other than the purpose for which it was designed, ATP, reserves the right to void the warranty. 4. All warranty claims must be made within the warranty period. Proof of purchase must be supplied. This warranty is non-transferable. 5. Please note that the warranty does not apply if the product or product part is damaged by accident, misuse, tampered with or modified in any way. 6. Normal wear items (seals, filters, etc.) are specifically excluded from warranty, unless found by Promax to be defective. WARRANTY SERVICE This warranty is given by ADVANCED TEST PRODUCTS, INC. Service under this warranty must be obtained by the following steps: Contact your local Promax Distributor. FULL ONE YEAR WARRANTY 22

24 ADVANCE TEST PRODUCTS Miramar, FL Telephone: (954) Fax: (866) Toll Free: (800) Made in USA Pro RevA

REFRIGERANT RECOVERY UNIT USER S OPERATING MANUAL RG5410A

REFRIGERANT RECOVERY UNIT USER S OPERATING MANUAL RG5410A REFRIGERANT RECOVERY UNIT USER S OPERATING MANUAL RG5410A TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION 4 OPERATING GUIDELINES 5-6 CARE AND MAINTENANCE OF YOUR RG5410A 6 ADDITIONAL RECOVERY TANK INFORMATION

More information

Additional users operating manual

Additional users operating manual Additional users operating manual For use with A2L Refrigerants e.g. R32, 1234yf, 143a, 1234ze This additional manual is valid for the following Promax Refrigerant Recovery Units: MiniMax-E; RG 5410A-E,

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which

More information

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4

More information

REFRIGERANT RECOVERY SYSTEM USER S OPERATING MANUAL 25176B

REFRIGERANT RECOVERY SYSTEM USER S OPERATING MANUAL 25176B REFRIGERANT RECOVERY SYSTEM USER S OPERATING MANUAL 25176B ADVANCED TEST PRODUCTS. INC Miramar, FL Telephone: (954) 499-5400 Fax: (954) 499-5454 Toll Free: (800) 327-5060 www.robinairhvac.com TABLE OF

More information

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual Model: Ariazone 601 HD Serial No: 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before operating

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED

More information

Ariazone 601HD Refrigerant Recovery&Recycling unit

Ariazone 601HD Refrigerant Recovery&Recycling unit Automotive Air-Conditioning Service Equipment Ariazone 601HD Refrigerant Recovery&Recycling unit OPERATOR MANUAL 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL RLV-700 REFRIGERANT RECOVERY / RECYCLING UNIT (PATENTED) NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 (215) 638-8909 FAX (215) 638-9270 REVISED 03-21-2018

More information

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability High Performance Oilless Residential Light Commercial Product Leadership Training Service Reliability User Manual 2020-9000 Rev. 1 December 2017 WARRANTY Bacharach, Inc. (Bacharach) warrants to the buyer

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

OPERATION & MAINTENANCE MANUAL TX600

OPERATION & MAINTENANCE MANUAL TX600 OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page

More information

OPER LV Wheeler Way

OPER LV Wheeler Way OPER RATING INSTRUCTIONS LV5 REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 Ph:(215) 638-8909 9 info@ @nrproducts.com LV5.DOC 9.17.2018 MODEL LV5 REFRIGERANT

More information

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Certified by ITS to meet SAE J2810 for R-134a Designed to meet new SAE J2851 for R-1234yf MANUAL GENERAL INFORMATION Table of

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning

More information

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Owner s Manual Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Model AC375C Recover, Recycle, and Recharge Unit for R-12 or R-134a Refrigerant Voltage: 220 230; 50 60 Hz SAFETY DEFINITIONS:

More information

R100 Oil-Less Refrigerant Recovery Unit

R100 Oil-Less Refrigerant Recovery Unit R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20

More information

Model K / K. Modelo K / K. Modèle K / K. Operating Manual

Model K / K. Modelo K / K. Modèle K / K. Operating Manual Operating Manual Model 34800-2K / 34801-2K Recovery/Recycling/Recharging Unit for R-12 and R-134a Refrigerants... English Modelo 34800-2K / 34801-2K Unidad de recuperación/reciclaje/recarga para refrigerantes

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) PREMIUM RECOVERY MACHINES OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR700C/E /J/JUK/S; TR710C/S TO BE OPERATED BY QUALIFIED PERSONNEL ONLY Evaluated

More information

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY Pro-Set TR500 SERIES Oilless Refrigerant Recovery System OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR500, TR500E, TR500J, TR500S TO BE OPERATED

More information

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE

More information

OPERATION & MAINTENANCE MANUAL RHS680

OPERATION & MAINTENANCE MANUAL RHS680 OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup

More information

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual (English) Table of Contents Page General Safety Instructions...2 System Overview...3 RecoverX-CAR Operation

More information

OPERATION & MAINTENANCE MANUAL TC670

OPERATION & MAINTENANCE MANUAL TC670 OPERATION & MAINTENANCE MANUAL TC670 Refrigerant Management Center (Convertible For Use With R12 or R134a) RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80342-02 TC670 CONVERTIBLE

More information

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC. Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER

More information

Caresaver Universal Refrigerant Recovery Unit

Caresaver Universal Refrigerant Recovery Unit Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2

More information

REFRIGERANT RECOVERY SYSTEMS

REFRIGERANT RECOVERY SYSTEMS REFRIGERANT RECOVERY 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSES YELLOW JACKET YJ-LTE Refrigerant

More information

OPERATION & MAINTENANCE MANUAL AC860

OPERATION & MAINTENANCE MANUAL AC860 OPERATION & MAINTENANCE MANUAL AC860 Refrigerant Handling System Manual P/N 035-80913-00 TABLE OF CONTENTS Startup & Safe Operation... 1 Introduction to the AC860... 2 Control Panel... 3 Keypad Functions...

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

OPERATION MANUAL COPYRIGHT APPION INC - ALL RIGHTS RESERVED

OPERATION MANUAL COPYRIGHT APPION INC - ALL RIGHTS RESERVED OPERATION MANUAL COPYRIGHT 2006 - APPION INC - ALL RIGHTS RESERVED Table of Contents Warnings and Safety Information 3 Refrigerant Storage Container Safety 3 Machine Usage 4 Standard Recovery Procedure

More information

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Some of these procedures need to be performed to conform to requirements of the Clean Air Act. Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.

More information

OPERATION & MAINTENANCE MANUAL AC880

OPERATION & MAINTENANCE MANUAL AC880 OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035-80749-00 TABLE OF CONTENTS AC880 Before Using the AC880... 2 Safety Precautions... 2 Using the AC880... 3 Setup... 4 Fill

More information

347002K/177002K/34900

347002K/177002K/34900 Service Manual Models: 347002K/177002K 34900/347012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation and Safety Precautions... 2 Depressurizing

More information

CC Series VACUUM PUMPS

CC Series VACUUM PUMPS CC Series VACUUM PUMPS OPERATING MANUAL Thank you for selecting a Javac select product! Please read this operation manual carefully before use. Only suitably qualified personnel should operate this equipment.

More information

REFRIGERANT SYSTEM SERVICE WARNINGS

REFRIGERANT SYSTEM SERVICE WARNINGS 2005 HVAC Refrigerant System - MX-5 Miata REFRIGERANT SYSTEM SERVICE WARNINGS USING/HANDLING UNAPPROVED REFRIGERANT Using a flammable refrigerant, such as OZ-12, in this vehicle is dangerous. In an accident,

More information

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery. HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant

More information

OPERATION MANUAL. FOR REFRIGERANT RECOVERY. DANGER Explosion Hazard. Do NOT use with hydrocarbons. See page 4.

OPERATION MANUAL.  FOR REFRIGERANT RECOVERY. DANGER Explosion Hazard. Do NOT use with hydrocarbons. See page 4. www.appiontools.com FOR REFRIGERANT RECOVERY OPERATION MANUAL DANGER Explosion Hazard. Do NOT use with hydrocarbons. See page 4. WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL

More information

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION UNIT OBJECTIVES After studying this unit, the reader should be able to Describe a standing pressure test. Choose a leak detector

More information

YELLOW JACKET Recovery Machines for every refrigerant, every size system

YELLOW JACKET Recovery Machines for every refrigerant, every size system YELLOW JACKET Recovery Machines for every refrigerant, every size system NEW RecoverX Family of Refrigerant Recovery Machines 5 YELLOW JACKET Refrigerant Recovery Machines the growing line for every size

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

Operating Manual Manual de Operación Manuel d utilisation

Operating Manual Manual de Operación Manuel d utilisation Operating Manual Manual de Operación Manuel d utilisation Model 17800B/17801B Recovery/Recycling/Recharging Unit for Multiple Refrigerants... 1 Modelo 17800B/17801B Unidad de recuperación/reciclado/recarga

More information

Service Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only

Service Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only Service Manual Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only Theory of Operation and Safety Precautions... 2 Component Descriptions... 3 Plumbing Diagram... 8 Pictorial Views...

More information

Operating Manual, Model K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1

Operating Manual, Model K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1 Operating Manual, Model 348002K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1 Refrigerant Recovery, Recycling and Recharging Station Series: 348002K/348012K Refrigerants:

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS Digital Refrigerant System Analyzer INSTRUCTION MANUAL ENGLISH LOW START PRS T-LOW SUPERHEAT MAXMIN kpa Bar MPa R TIME P T HIGH END PRS T-HIGH SUBCOOL VAC 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com

More information

Quest Dry 105, 155, and 205 Dual

Quest Dry 105, 155, and 205 Dual Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

OPERATION MANUAL FOR REFRIGERANT RECOVERY

OPERATION MANUAL FOR REFRIGERANT RECOVERY FOR REFRIGERANT RECOVERY CAUTION Explosion Hazard. Do NOT use with hydrocarbons. See page 4. WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT. OPERATION

More information

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700 A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S File Literature Number 1144-01-1 Installation Operation & Maintenance Manual CONTINUOUS REFRIGERANT DEHYDRATOR Model: CD-120 For use with Refrigerants R-11, R-123, R-12, R-22, R-134a

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Operating Manual. Model 34700Z / 17700Z Recovery, Recycling, Recharging Unit

Operating Manual. Model 34700Z / 17700Z Recovery, Recycling, Recharging Unit Operating Manual Model 34700Z / 17700Z Recovery, Recycling, Recharging Unit Model 34700Z / 17700Z Recovery, Recycling, & Recharging Unit SAFETY DEFINITIONS: Follow all WARNING, CAUTION, IMPORTANT, and

More information

Cooling System Equipment

Cooling System Equipment Air Conditioning Service Centers Leak Detectors Recyclers 2007 Buyers Guide 223 Brake & Refrigerant Handling REFRIGERANT RECOVERY/RECYCLING SYSTEMS Cool-Tech R-134A Recovery, Recycling And Recharging System

More information

Ariazone 5001 HFO-1234yf

Ariazone 5001 HFO-1234yf Automotive Air-Conditioning Service Equipment Ariazone 5001 HFO-1234yf OPERATOR MANUAL 1 Contents Page 1. Introduction... 3 2. Safety... 4 3. Technical Features... 5 4. Main Parts & Features... 6 5. Preparing

More information

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions Quest CDG Dry 74 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction

More information

Operating Manual. Series 12134B Recovery/Recycling/Recharging Unit for R-12 and R-134a

Operating Manual. Series 12134B Recovery/Recycling/Recharging Unit for R-12 and R-134a Operating Manual Series 12134B Recovery/Recycling/Recharging Unit for R-12 and R-134a LISTED 80S2 Design Certified by Underwriters Laboratories Inc., to meet SAE J1770 for recycling R-12 and R-134a using

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION Service Application Manual SAM Chapter 630-158 Section 2C DEEP VACUUM: ITS PRINCIPLE AND APPLICATION Adapted from material provided by JB Industries. Reprinted with permission. INTRODUCTION With the deep

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING XJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page DESCRIPTION AND OPERATION SERVICE WARNINGS AND PRECAUTIONS...1 COMPRESSOR - 2.5L VM DIESEL....3 COMPRESSOR CLUTCH

More information

OAM Purger. Oil Acid & Moisture Purge Unit. Redi Controls, Inc. Installation, Operation & Maintenance Manual. High Pressure Centrifugal Chillers

OAM Purger. Oil Acid & Moisture Purge Unit. Redi Controls, Inc. Installation, Operation & Maintenance Manual. High Pressure Centrifugal Chillers OAM Purger Installation, Operation & Maintenance Manual Redi Controls, Inc. Literature File No. 1120-02 Rev-3-14-05 Oil Acid & Moisture Purge Unit for use on High Pressure Centrifugal Chillers Model: OAM-PRG-HPC100

More information

DiscovR R134a Refrigerant Identifier

DiscovR R134a Refrigerant Identifier Model 16009 DiscovR R134a Refrigerant Identifier Operating Manual Table of Contents Safety Precautions... 1 Description... 4 Operating Instructions.... 5 Fault Codes.... 7 Troubleshooting... 7 Replacement

More information

User manual Flushing device VAS 6337/1a

User manual Flushing device VAS 6337/1a User manual Flushing device VAS 6337/1a 2 Content Safety warnings 3 Flushing with R134a refrigerant 4 1.0 Preparing the Vehicle AC System 4 1.1 Connecting the recovery recharge Unit 6 1.2 Flush procedure

More information

1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below:

1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below: SUPER SEAL HISTORY Work on Super Seal leak sealants for residential and commercial systems began in August 1999, after the successful introduction of Cliplight's Super Seal Pro, for automotive systems.

More information

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM AIR CONDITIONING BASICS COMPRESSOR REPLACEMENT OVERVIEW AND IMPORTANT INSTRUCTIONS The air conditioning compressor

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02 Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE

More information

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr

Vacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr Vacuum Gauge Measures lower-than-atmospheric pressure Digital scales microns psi in. Hg millibars pascals torr millitorr (Sealed Unit Parts Co., Inc.) Compound Gauge Measures pressure and vacuum Low-side

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

Operating Manual. Model K/ K Recovery/Recycling/Recharging Unit

Operating Manual. Model K/ K Recovery/Recycling/Recharging Unit Operating Manual Model -K/-K Recovery/Recycling/Recharging Unit Model -K (for R- refrigerant) Model -K (for R-a refrigerant) Recover, Recycle, and Recharge Unit SAFETY DEFINITIONS: Follow all WARNING,

More information

P/N CC-100. Coolant Circulator. Operation manual

P/N CC-100. Coolant Circulator. Operation manual P/N 4411-0019 CC-100 Coolant Circulator Operation manual Manual Version 1 Revision B July 1, 1998 Table of Contents Chapter 1 Introduction... 5 Description...5 Specifications...5 Chapter 2 Warnings...

More information

Mobile Air-Con Service Solution. AC7000 Operation Manual

Mobile Air-Con Service Solution. AC7000 Operation Manual Mobile Air-Con Service Solution AC7000 Operation Manual Cool-It Mobile HVAC Group Contents 1 About this operation manual.......................................... 2 1.1 Cool-It Hotline......................................................

More information

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE XAACT Xtract 200 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00018 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important

More information

DRY 150 Quest PowerDry 1300

DRY 150 Quest PowerDry 1300 DRY 150 Quest PowerDry 1300 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate

More information

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING 12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future

More information

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number: WID260P Water Dispenser with Ice Maker BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. Avanti has a policy of continuous improvement on

More information

RLD-H10G Refrigerant Leak Detectors

RLD-H10G Refrigerant Leak Detectors FANs 125, 121 Product/Technical Bulletin RLD-H10G Issue Date 0396 RLD-H10G Refrigerant Leak Detectors The RLD-H10G is a professional grade leak detector for use by refrigeration and air conditioning technicians.

More information

Quest 105, Dry155, and 205 Dual

Quest 105, Dry155, and 205 Dual Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

MASS. MARITIME ACADEMY

MASS. MARITIME ACADEMY MASS. MARITIME ACADEMY REFRIGERATION LAB OUTLINE Rev.3 Fall 2015 Table of Content Page Lab #1: Introduction to refrigeration system components, tools and procedures 1 Lab #2: Familiarization, operation,

More information

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling

More information

Installation Instructions

Installation Instructions 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information